首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The overall objective of this study was to introduce knee joint power as a potential measure to investigate knee joint stability following total knee arthroplasty (TKA). Specific aims were to investigate whether weakened knee joint stabilizers cause abnormal kinematics and how it influences the knee joint kinetic (i.e., power) in response to perturbation.Patient-specific musculoskeletal models were simulated with experimental gait data from six TKA patients (baseline models). Muscle strength and ligament force parameter were reduced by up to 30% to simulate weak knee joint stabilizers (weak models). Two different muscle recruitment criteria were tested to examine whether altered muscle recruitment pattern can mask the influence of weakened stabilizers on the knee joint kinematics and kinetics. Level-walking knee joint kinematics and kinetics were calculated though force-dependent kinematic and inverse dynamic analyses. Bode analysis was then recruited to estimate the knee joint power in response to a simulated perturbation.Weak models resulted in larger anterior-posterior (A-P) displacement and internal-external (I-E) rotation compared to baseline (I-E: 18.4 ± 8.5 vs. 11.6 ± 5.7 (deg), A-P: 9.7 ± 5.6 vs. 5.5 ± 4.1 (mm)). Changes in muscle recruitment criterion however altered the results such that A-P and I-E were not notably different from baseline models. In response to the simulated perturbation, weak models versus baseline models generated a delayed power response with unbounded magnitudes. Perturbed power behavior of the knee remained unaltered regardless of the muscle recruitment criteria.In conclusion, impairment at the knee joint stabilizers may or may not lead to excessive joint motions but it notably affects the knee joint power in response to a perturbation. Whether perturbed knee joint power is associated with the patient-reported outcome requires further investigation.  相似文献   

2.
3.
Proper tension of the knee’s soft tissue envelope is important during total knee arthroplasty; incorrect tensioning potentially leads to joint stiffness or instability. The latter remains an important trigger for revision surgery. The use of sensors quantifying the intra-articular loads, allows surgeons to assess the ligament tension at the time of surgery. However, realistic target values are missing. In the framework of this paper, eight non-arthritic cadaveric specimens were tested and the intra-articular loads transferred by the medial and lateral compartment were measured using custom sensor modules. These modules were inserted below the articulating surfaces of the proximal tibia, with the specimens mounted on a test setup that mimics surgical conditions. For both compartments, the highest loads are observed in full extension. While creating knee flexion by lifting the femur and flexing the hip, mean values (standard deviation) of 114 N (71 N) and 63 N (28 N) are observed at 0° flexion for the medial and lateral compartment respectively. Upon flexion, both medial and lateral loads decrease with mean values at 90° flexion of 30 N (22 N) and 6 N (5 N) respectively. The majority of the load is transmitted through the medial compartment. These observations are linked to the deformation of the medial and lateral collaterals, in addition to the anatomy of the passive soft tissues surrounding the knee. In conclusion, these findings provide tangible clinical guidance in assessing the soft tissue loads when dealing with anatomically designed total knee implants.  相似文献   

4.
ObjectiveTo investigate neuromuscular activation of quadriceps bellies during different tasks in patients before and after total knee arthroplasty (TKA).MethodsTwenty-six patients scheduled for TKA and 16 control subjects performed three isometric tasks: knee extension (KE), hip flexion (HF), hip flexion with contralateral hip extension (HFE). Surface electromyography signals of rectus femoris, vastus medialis and vastus lateralis were collected the day before (T0), at one (T1) and three (T2) days after surgery, whereas control subjects underwent a single evaluation. The Root Mean Square peak normalized for its highest value during the three tasks (nRMS-peak) was used as index of maximum neuromuscular activation for each belly. Sixteen patients performed the postoperative assessment, due to the placement of an elastomeric pump aimed at reducing pain in 10 patients.ResultsPatients showed lower rectus femoris nRMS-peak during KE compared to HF and HFE before and after surgery (p < 0.001), as occurred in control subjects. Differently from control subjects, patients showed higher vastus medialis and vastus lateralis nRMS-peak during HF compared to KE at T1 (p = 0.008) and T2 (p = 0.039).ConclusionTKA modified quadriceps neuromuscular activation during different tasks performed the same biomechanical condition. These findings may be considered in planning physiotherapy interventions after TKA.  相似文献   

5.
The effect of femoral component malrotation on patellar biomechanics   总被引:1,自引:0,他引:1  
Patellofemoral complications are among the important reasons for revision knee arthroplasty. Femoral component malposition has been implicated in patellofemoral maltracking, which is associated with anterior knee pain, subluxation, fracture, wear, and aseptic loosening. Rotating-platform mobile bearings compensate for malrotation between the tibial and femoral components and may, therefore, reduce any associated patellofemoral maltracking. To test this hypothesis, we developed a dynamic model of quadriceps-driven open-kinetic-chain extension in a knee implanted with arthroplasty components. The model was validated using tibiofemoral and patellofemoral kinematics and forces measured in cadaver knees. Knee kinematics and patellofemoral forces were measured after simulating malrotation (±3°) of the femoral component. Rotational alignment of the femoral component affected tibial rotation near full extension and tibial adduction at higher flexion angles. External rotation of the femoral component increased patellofemoral lateral tilt, lateral shift, and lateral shear forces. Up to 21° of bearing rotation relative to the tibia was noted in the rotating-bearing condition. However, the rotating bearing had minimal effect in reducing the patellofemoral maltracking or shear induced by femoral component rotation. The rotating platform does not appear to be forgiving of malalignment of the extensor mechanism resulting from femoral component malrotation. These results support the value of improving existing methodologies for accurate femoral component alignment in total knee arthroplasty.  相似文献   

6.
Unbalanced contact force on the tibial component has been considered a factor leading to loosening of the implant and increased wear of the bearing surface in total knee arthroplasty. Because it has been reported that good alignment cannot guarantee successful clinical outcomes, the soft tissue balance should be checked together with the alignment. Finite element models of patients' lower extremities were developed to analyse the medial and lateral contact force distribution on the tibial insert. The distributions for four out of five patients were not balanced equally, even though the alignment angles were within a clinically acceptable range. Moreover, the distribution was improved by changing soft tissue release and ligament tightening for the specific case. Integration of the biomechanical modelling, image matching and finite element analysis techniques with the patient-specific properties and various dynamic loading would suggest a clinically relevant pre-operative planning for soft tissue balancing.  相似文献   

7.
The application of 3D printing patient specific instrumentation model in total knee arthroplasty was explored to improve the operative accuracy and safety of artificial total knee arthroplasty. In this study, a total of 52 patients who need knee replacement were selected as the study objects, and 52 patients were divided into experimental group and control group. First, the femoral mechanical-anatomical angle (FMAA), lateral femoral angle (LFA), hip-knee-ankle angle (HKA), femorotibial angle (FTA) of research objects in both groups were measured. Then, the blood loss during the operations, drainage volume after operations, total blood loss, hidden blood loss, and hemoglobin decrease of the experiment group and the control group were measured and calculated. Finally, the postoperative outcomes of patients who underwent total knee arthroplasty were evaluated. The results showed that before the operations, in the PSI group, the femoral mechanical-anatomical angle (FMAA) was (6.9 ± 2.4)°, the lateral femoral angle (LFA) was (82.4 ± 1.6)°, the hip-knee-ankle angle (HKA) was (166.4 ± 1.4)°, and the femorotibial angle (FTA) was (179.5 ± 7.3)°. In the CON group, the FMAA was (5.8 ± 2.4)°, the LFA was (81.3 ± 2.1)°, the HKA was (169.5 ± 1.9)°, and the FTA was (185.4 ± 5.4)°. The differences in these data between the two groups were not statistically significant (P > 0.05). After the operations, in the PSI group, the total blood loss, the hidden blood loss, and the hemoglobin (Hb) decrease were respectively (420.2 ± 210.5), (240.5 ± 234.5), and (1.7 ± 0.9); in the CON group, the total blood loss, the hidden blood loss, and the Hb decrease were respectively (782.1 ± 340.4), (450.9 ± 352.6), and (2.9 ± 1.0). These data of both groups were statistically significant (P < 0.05). Therefore, it can be seen that the 3D printing patient specific instrumentation model can effectively simulate the lower limb coronal force line and was highly consistent of the preoperative software simulation plan. In addition, the random interviews of patients who underwent total knee arthroplasty showed that the knees of patients had recovered well. The application of 3D printing patient specific instrumentation model in artificial total knee arthroplasty can effectively improve the operative accuracy and safety, and the clinical therapeutic effects were significant.  相似文献   

8.
BackgroundHeparin-induced thrombocytopenia is caused by antibodies (Abs) specific to platelet factor 4 (PF4)/heparin complexes. In this study, we evaluated the rates of seroconversion of anti-PF4/heparin Ab between patients with rheumatoid arthritis (RA) and with osteoarthritis (OA) who underwent total knee arthroplasty.MethodsThe subjects of this randomized controlled trial were 124 patients who underwent total knee arthroplasty (TKA) and received edoxaban with or without a foot pump as thromboprophylaxis. We measured anti-PF4/heparin Abs before and 10 days after surgery, as well as preoperative PF4, using commercially available ELISAs. We also used the database of J-PSVT, a hospital-based, prospective cohort study designed to document the effectiveness of thromboprophylactic agents during arthroplasty.ResultsThe rates of seroconversion to anti-PF4/heparin Ab were lower in RA patients (4.0 %) than in OA patients (25.5 %). The anti-PF4/heparin IgG optical density (OD) values did not differ before and after surgery in RA patients. In contrast, there was a significant increase in anti-PF4/heparin IgG OD values in OA patients after TKA. In the J-PSVT data, the postoperative seroconversion rates of anti-PF4/heparin Ab were lower in RA patients (10.4 %) than in OA patients (21.8 %) who received fondaparinux. The titers of anti-CCP Ab were significantly lower in RA patients with postoperative ant-PF4/heparin Ab compared with those without postoperative ant-PF4/heparin Ab There was no significant difference in preoperative PF4 levels between RA patients and OA patients. The heparin-binding affinity of the circulating PF4 was similar between RA patients and OA patients; however, the IgG fractions isolated from the sera of RA patients contained PF4 more frequently (69.2 %) than those from OA patients (10.2 %).ConclusionsOur results showed a reduced likelihood of postoperative anti-PF/heparin Ab production in RA patients compared with OA patients. This suggests that the mechanisms underlying the anti-PF4 immune response in RA patients differ from the mechanisms of the anti-PF4/heparin immune response seen in OA patients after joint replacement.

Trial registration

ISRCTN 18090286. Registered 8 July 2016  相似文献   

9.
Kneeling is required during daily living for many patients after total knee replacement (TKR), yet many patients have reported that they cannot kneel due to pain, or avoid kneeling due to discomfort, which critically impacts quality of life and perceived success of the TKR procedure. The objective of this study was to evaluate the effect of component design on patellofemoral (PF) mechanics during a kneeling activity. A computational model to predict natural and implanted PF kinematics and bone strains after kneeling was developed and kinematics were validated with experimental cadaveric studies. PF joint kinematics and patellar bone strains were compared for implants with dome, medialized dome, and anatomic components. Due to the less conforming nature of the designs, change in sagittal plane tilt as a result of kneeling at 90° knee flexion was approximately twice as large for the medialized-dome and dome implants as the natural case or anatomic implant, which may result in additional stretching of the quadriceps. All implanted cases resulted in substantial increases in bone strains compared with the natural knee, but increased strains in different regions. The anatomic patella demonstrated increased strains inferiorly, while the dome and medialized dome showed increases centrally. An understanding of the effect of implant design on patellar mechanics during kneeling may ultimately provide guidance to component designs that reduces the likelihood of knee pain and patellar fracture during kneeling.  相似文献   

10.
The aim of this study was to investigate the prevalence of abnormal knee biomechanical patterns in 40 patients with a modern TKA prosthesis, compared to 40 matched control participants when ascending and descending stairs. Fewer patients were able to ascend (65%) or descend stairs (53%) unassisted than controls (83%). Of the participants who could ascend and descend, cluster analysis classified most patients (up to 77%) as demonstrating a similar knee moment pattern as all controls. A small subgroup of patients who completed the tasks did so with distinctly abnormal biomechanics compared to other patients and controls. These findings suggest that recovery of normal stair climbing is possible. However, rehabilitation might be more effective if it were tailored to account for these differences between patients.  相似文献   

11.
Polyethylene remains the most popular bearing material for total knee arthroplasty (TKA). Despite its widespread use, wear continue to be one of major factors implicated in revision surgery. Sliding distance, cross-shear, and contact stress are the major factors influencing polyethylene wear. As previous studies have either relied on wear simulations, computational modeling, or in vitro measurements to quantify sliding distance and cross-shear, in vivo subject-specific sliding distance and cross-shear after bi-cruciate retaining (BCR) TKA has not been previously reported. The objective of this study was to quantify the 6°-of-freedom (6DOF) in vivo kinematics, sliding distance, and cross-shear in BCR TKA patients during gait. Twenty-nine unilateral BCR TKA patients performed level walking on a treadmill under dual fluoroscopic imaging system (DFIS) surveillance. Cumulative normalized sliding distances between the lateral and medial compartments did not change significantly (p > 0.05) during the gait cycle. Although the total normalized sliding distance was similar between the lateral and medial compartments, the cross-shear at the lateral compartment differed significantly from that at the medial compartment (p < 0.001). Significant differences in the relative length positions of the peak sliding distance and cross-shear were found between the lateral and medial bearing components. The flexion-extension motion of the reconstructed knee was more associated with the linear displacements (anterior-posterior, R2 = 0.6; lateral-medial, R2 = 0.8, proximal-distal, R2 = 0.7) than the angular displacement (varus-valgus, R2 = 0.18; internal-external rotation, R2 = 0.28). Despite some differences in peak sliding distance and cross-shear positons, our results suggest similar articular contact patterns between the lateral and medial compartments in BCR TKA patients during gait. The data could provide insights into understanding the potential wear patterns in BCR TKAs.  相似文献   

12.
The design of a total knee replacement implant needs to take account the complex surfaces of the knee which it is replacing. Ensuring design performance of the implant requires in vitro testing of the implant. A considerable amount of time is required to produce components and evaluate them inside an experimental setting. Numerous adjustments in the design of an implant and testing each individual design can be time consuming and expensive.Our solution is to use the OpenSim simulation software to rapidly test multiple design configurations of implants. This study modeled a testing rig which characterized the motion and laxity of knee implants. Three different knee implant designs were used to test and validate the accuracy of the simulation: symmetrical, asymmetric, and anatomic. Kinematics were described as distances measured from the center of each femoral condyle to a plane intersecting the most posterior points of the tibial condyles between 0 and 135° of flexion with 15° increments. Excluding the initial flexion measurement (∼0°) results, the absolute differences between all experimental and simulation results (neutral path, anterior-posterior shear, internal-external torque) for the symmetric, asymmetric, and anatomical designs were 1.98 mm ± 1.15, 1.17 mm ± 0.89, and 1.24 mm ± 0.97, respectively. Considering all designs, the accuracy of the simulation across all tests was 1.46 mm ± 1.07. It was concluded that the results of the simulation were an acceptable representation of the testing rig and hence applicable as a design tool for new total knees.  相似文献   

13.
Component mal-alignment in total knee arthroplasty has been associated with increased revision rates and poor clinical outcomes. A significant source of variability in traditional, jig-based total knee arthroplasty is the performance of the surgeon. The purpose of this study was to determine the most sensitive steps in the femoral and tibia arthroplasty procedures. A computational model of the total knee arthroplasty procedure was created, and Monte Carlo simulations were performed that included surgeon variability in each step of the procedure. The proportion of well-aligned components from the model agrees with clinical literature in most planes. When components must be aligned within ±3° in all planes, component alignment was most sensitive to the accuracy of identifying the lateral epicondyle for the femoral component, and to the precision of the transverse plane alignment of the extramedullary guide for the tibial component. This model can be used as a tool for evaluating different procedural approaches or sources of variability to improve the quality of the total knee arthroplasty procedure.  相似文献   

14.
The purpose of this study was to investigate knee biomechanics in uphill walking on slopes of 5°, 10° and 15° for total knee replacement (TKR) patients. Twenty-five post-TKR patients and ten healthy controls performed five walking trials on level ground and different slopes on an instrumented ramp system. A 2 × 2 × 4 (limb × group × incline slope) mixed model ANOVA was used to examine selected variables. The peak knee extension moment (KEM) was greater in 15° uphill walking compared to level, 5° and 10° uphill walking. TKR patients had lower peak KEM and smaller knee extension range of motion than healthy controls in all walking conditions. The Replaced Limb showed lower peak KEM in 10° and 15° uphill walking than the Non-replaced Limb and smaller knee extension range of motion (ROM) in 10° uphill walking. Knee extension and abduction ROM increased with increased incline angles. The greater peak loading-response vertical ground reaction force was found in level walking compared to three levels of uphill walking. The peak loading-response knee abduction moment was greater in level walking compared to 10° and 15° uphill walking. However, the medial knee contact force was greater in non-replaced limb compared to replaced limb in 10° and 15° uphill walking. The results suggest 5° uphill walking may have the potential to become a safe exercise for unilateral TKR patients.  相似文献   

15.
Loosening and migration of tibial prostheses have been identified as causes of early total knee replacement (TKR) failure. The problem is made more complex when defects occur in the proximal tibia compromising fixation and alignment. Clinical studies using metal augments have shown these to be an alternative to other means of defect treatment. Finite element (FE) analysis can be used to identify regions that may be prone to loosening and migration. In the current work, 3D FE models of TKR uncontained type-2 defects treated with block augments have been constructed and analysed. It has been shown that a metal augment is the most suitable. The use of bone cement (PMMA) to fill proximal defects is not considered suitable as stresses carried by the cement block exceed those of the fatigue limit of bone cement. It has been shown that the stresses in the proximal cancellous bone of block-augmented models are significantly below levels likely to cause damage due to overloading. Furthermore, the use of stem extensions has been shown to reduce the cancellous bone stresses in the proximal region thus increasing the likelihood of bone resorption. Given this, it is recommended that stem extensions are not required unless necessary to mitigate some other problem.  相似文献   

16.
Patella alta is common in cerebral palsy, especially in patients with crouch gait. Correction of patella alta has been advocated in the treatment of crouch, however the appropriate degree of correction and the implications for knee extensor function remain unclear. Therefore, the goal of this study was to assess the impact of patellar position on quadriceps and patellar tendon forces during normal and crouch gait. To this end, a lower extremity musculoskeletal model with a novel 12 degree of freedom knee joint was used to simulate normal gait in a healthy child, as well as mild (23 deg min knee flexion in stance), moderate (41 deg), and severe (67 deg) crouch gait in three children with cerebral palsy. The simulations revealed that quadriceps and patellar tendon forces increase dramatically with crouch, and are modulated by patellar position. For example with a normal patellar tendon position, peak patellar tendon forces were 0.7 times body weight in normal walking, but reached 2.2, 3.2 and 5.4 times body weight in mild, moderate and severe crouch. Moderate patella alta acted to reduce quadriceps and patellar tendon loads in crouch gait, due to an enhancement of the patellar tendon moment arms with alta in a flexed knee. In contrast, patella baja reduced the patellar tendon moment arm in a flexed knee and thus induced an increase in the patellar tendon loads needed to walk in crouch. Functionally, these results suggest that patella baja could also compromise knee extensor function for other flexed knee activities such as chair rise and stair climbing. The findings are important to consider when using surgical approaches for correcting patella alta in children who exhibit crouch gait patterns.  相似文献   

17.
目的:探讨全膝关节置换术(TKA)治疗晚期类风湿性膝关节炎(RA)的早期临床疗效和安全性。方法:回顾性分析2006年~2011年接受TKA治疗的69例(102膝)晚期膝关节RA患者的临床资料,术后及随访时分析患者的影像学资料,末次随访时进行膝关节HSS评分,采用英国矫形外科协会标准评定患者满意度,SF-36健康量表评定患者的生活质量。结果:54例(81膝)患者术后获得2~7年(平均4.3年)随访;6例(7膝)死亡,6例(10膝)失访,3例(4膝)翻修,获得随访患者中1例(1膝)发生下肢深静脉血栓,经介入放置滤网治疗康复后出院,1例(1膝)感染。末次随访时,膝关节活动度(ROM)从术前平均(71.03°±29.51°)提高至(92.26°±10.29°),膝关节HSS评分从术前平均(47.30±10.06)分提高至(75.93±9.17)分;疼痛发生率和疼痛评分均较术前显著降低;冠状面和矢状面畸形率均较术前显著降低;身体健康(PCS)平均(47.98±6.96)分,心理健康(MCS)平均(41.45±5.67)分,均较术前显著增加,差异均有统计学意义(P0.05)。患者的治疗满意率为96.30%,膝关节假体X线片采用膝关节学会的X线评价与计分系统评价未见假体松动。结论:TKA治疗晚期膝关节RA患者2~7年的临床及影像学效果良好,未发现骨溶解、假体松动及严重衬垫磨损等并发症。  相似文献   

18.
We have developed a four-dimensional (4D) model of the lower extremities after total hip arthroplasty in patients. The model can aid in preventing complications such as dislocation and wearing of the sliding surface. The skeletal structure and implant alignment were obtained from CT data. We applied registration method using CAD data to estimate accurate implant alignment from scattered CT data. The reconstructed three-dimensional (3D) skeletal model was combined with motion capture data that were acquired by an optical tracking system. We displayed the patient's skeletal movement and analyzed several parameters that relate to complications. The patient's skeletal model was superimposed onto video footage that was taken by a synchronized and calibrated digital video camera. For validation of the measurement error in this system, we used open MRI to evaluate the relative movement between skin markers and bones. This system visually represents not only the 3D anatomical structure, but also 4D dynamic functions that include the time sequential transitions of components and their positions. The open MRI results indicated that the average error in hip angle was within 5° for each static posture. This system enables clinicians to analyze patient's motions on the basis of individual differences. We found that our system was an effective tool in providing precise guidance of daily postoperative motions that was individualized for each patient. This system will be applicable for surgical planning, assessment of postoperative activities, and the development of new surgical techniques, materials, and prosthetic designs.  相似文献   

19.
Ultra high molecular weight polyethylene (PE) remains the primary bearing surface of choice in total knee replacements (TKR). Wear is controlled by levels of cross-shear motion and contact stress. The aim of this study was to compare the wear of fixed-bearing total knee replacements with curved and flat inserts and to test the hypothesis that the flat inserts which give higher contact stresses and smaller contact areas would lead to lower levels of surface wear. A low-conforming, high contact stress knee with a low-medium level of cross shear resulted in significantly lower wear rates in comparison to a standard cruciate sacrificing fixed-bearing knee. The low wear solution found in the knee simulator was supported by fundamental studies of wear as a function of pressure and cross shear in the pin on plate system. Current designs of fixed-bearing knees do not offer this low wear solution due to their medium cross shear, moderate conformity and medium contact stress.  相似文献   

20.
Previous in vivo studies have observed that current designs of posterior stabilised (PS) total knee replacements (TKRs) may be ineffective in restoring normal kinematics in Late flexion. Computer-based models can prove a useful tool in improving PS knee replacement designs. This study investigates the accuracy of a two-dimensional (2D) sagittal plane model capable of predicting the functional sagittal plane kinematics of PS TKR implanted knees against direct in vivo measurement. Implant constraints are often used as determinants of anterior–posterior tibio-femoral positioning. This allowed the use of a patello-femoral modelling approach to determine the effect of implant constraints. The model was executed using motion simulation software which uses the constraint force algorithm to achieve a solution. A group of 10 patients implanted with Scorpio PS implants were recruited and underwent fluoroscopic imaging of their knees. The fluoroscopic images were used to determine relative implant orientation using a three-dimensional reconstruction method. The determined relative tibio-femoral orientations were then input to the model. The model calculated the patella tendon angles (PTAs) which were then compared with those measured from the in vivo fluoroscopic images. There were no significant differences between the measured and calculated PTAs. The average root mean square error between measured and modelled ranged from 1.17° to 2.10° over the flexion range. A sagittal plane patello-femoral model could conceivably be used to predict the functional 2D kinematics of an implanted knee joint. This may prove particularly useful in optimising PS designs.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号