首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
The immature core protein (p23, residues 1 to 191) of hepatitis C virus undergoes posttranslational modifications including intramembranous proteolysis within its C-terminal signal sequence by signal peptide peptidase to generate the mature form (p21). In this study, we analyzed the cleavage site and other amino acid modifications that occur on the core protein. To produce the posttranslationally modified core protein, we used a baculovirus-insect cell expression model system. As previously reported, p23 is processed to form p21 in insect as well as in mammalian cells. p21 was found to be associated with the cytoplasmic membrane, and its significant portion behaved as an integral membrane protein. The protein was purified from the membrane by a simple and unique procedure on the basis of its membrane-binding properties and solubility in detergents. Matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) analysis of purified p21 showed that the average molecular mass (m/z 19,307) of its single-charged ion differs by m/z 1,457 from that calculated for p23. To determine the posttranslational modifications, tryptic p21 peptides were analyzed by MALDI-TOF MS. We found three peptides that did not match the theoretically derived peptides of p23. Analysis of these peptides by MALDI-TOF tandem MS revealed that they correspond to N-terminal peptides (residues 2 to 9 and 2 to 10) starting with alpha-N-acetylserine and C-terminal peptide (residues 150 to 177) ending with phenylalanine. These results suggest that the mature core protein (molecular mass of 19,306 Da) includes residues 2 to 177 and that its N terminus is blocked with an acetyl group.  相似文献   

2.
Human apolipoprotein B100 (apoB100) has 19 potential N-glycosylation sites, and 16 asparagine residues were reported to be occupied by high-mannose type, hybrid type, and monoantennary and biantennary complex type oligosaccharides. In the present study, a site-specific glycosylation analysis of apoB100 was carried out using reversed-phase high-performance liquid chromatography coupled with electrospray ionization tandem mass spectrometry (LC/ESI MS/MS). ApoB100 was reduced, carboxymethylated, and then digested by trypsin or chymotrypsin. The complex mixture of peptides and glycopeptides was subjected to LC/ESI MS/MS, where product ion spectra of the molecular ions were acquired data-dependently. The glycopeptide ions were extracted and confirmed by the presence of carbohydrate-specific fragment ions, such as m/z 204 (HexNAc) and 366 (HexHexNAc), in the product ion spectra. The peptide moiety of glycopeptide was determined by the presence of the b- and y-series ions derived from its amino acid sequence in the product ion spectrum, and the oligosaccharide moiety was deduced from the calculated molecular mass of the oligosaccharide. The heterogeneity of carbohydrate structures at 17 glycosylation sites was determined using this methodology. Our data showed that Asn2212, not previously identified as a site of glycosylation, could be glycosylated. It was also revealed that Asn158, 1341, 1350, 3309, and 3331 were occupied by high-mannose type oligosaccharides, and Asn 956, 1496, 2212, 2752, 2955, 3074, 3197, 3438, 3868, 4210, and 4404 were predominantly occupied by mono- or disialylated oligosaccharides. Asn3384, the nearest N-glycosylation site to the LDL-receptor binding site (amino acids 3359-3369), was occupied by a variety of oligosaccharides, including high-mannose, hybrid, and complex types. These results are useful for understanding the structure of LDL particles and oligosaccharide function in LDL-receptor ligand binding.  相似文献   

3.
Biniossek ML  Schilling O 《Proteomics》2012,12(9):1303-1309
Peptide sequences lacking basic residues (arginine, lysine, or histidine, referred to as "base-less") are of particular importance in proteomic experiments targeting protein C-termini or employing nontryptic proteases such as GluC or chymotrypsin. We demonstrate enhanced identification of base-less peptides by focused analysis of singly charged precursors in liquid chromatography (LC) electrospray ionization (ESI) tandem mass spectrometry (MS/MS). Singly charged precursors are often excluded from fragmentation and sequence analysis in LC-MS/MS. We generated different pools of base-less and base-containing peptides by tryptic and nontryptic digestion of bacterial proteomes. Focused LC-MS/MS analysis of singly charged precursor ions yielded predominantly base-less peptide identifications. Similar numbers of base-less peptides were identified by LC-MS/M Sanalysis targeting multiply charged precursors. There was little redundancy between the base-less sequences derived by both MS/MS schemes. In the present experimental outcome, additional LC-MS/MS analysis of singly charged precursors substantially increased the identification rate of base-less sequences derived from multiply charged precursors. In conclusion, LC-MS/MS based identification of base-less peptides is substantially enhanced by additional focused analysis of singly charged precursors.  相似文献   

4.
Methods for on-chip protein analysis   总被引:7,自引:0,他引:7  
The unambiguous identification of peptides/proteins is crucial for the definition of the proteome. Using ProteinChip Array technology also known as surface-enhanced laser desorption/ionization-time of flight mass spectrometry (SELDI-TOF MS), we developed experimental protocols and probed test conditions required for the protein identification on ProteinChip surfaces. We were able to directly digest peptides/proteins on-chip surfaces by specific proteases, such as trypsin, and to obtain the peptide mass fingerprint of the sample under investigation by its direct analysis on a simple laser desorption/ionization mass spectrometer. Furthermore, tandem mass spectrometry was performed on several of the resulting tryptic peptides by using collision quadrupole time of flight (Qq-TOF) MS/MS via the ProteinChip interface, thus allowing the unambiguous identification of the protein(s) within the sample. In addition, we were able to identify the C-terminal sequence of peptides by their digestion with carboxypeptidase Y directly on ProteinChip surfaces coupled with SELDI-TOF MS analysis of the resulting peptide mass ladders employing the instrument's protein ladder sequence software. Moreover, the removal of up to nine amino acid residues from the C-terminal end of a peptide extends the functional range of Qq-TOF MS/MS sequence determination to over 3000 m/z. The utility of these procedures for the proteome exploration are discussed.  相似文献   

5.
Novel biomarkers for multiple sclerosis (MS) could improve diagnosis and provide clues to pathogenesis. In this study surface-enhanced laser desorption/ionization time-of-flight mass spectrometry was used to analyze protein expression in CSF from 46 MS patients, 46 healthy siblings to the patients, and 50 unrelated healthy controls. Twenty-four proteins in the mass range 2–10 kDa were expressed at significantly different levels ( p  < 0.01) in a robust manner when comparing the three groups. Identities of three proteins were determined using biochemical purification followed by tandem mass spectrometric analysis. Immunoprecipitation experiments confirmed the identities for two peptides derived from chromogranin B ( m / z 6252) and from secretogranin II ( m / z 3679). These peptides were all decreased in MS when compared with siblings or controls. Radioimmunoassays specific for each peptide confirmed these differences. The lowered concentrations did not correlate to the axonal damage marker neurofilament light protein and may thus reflect functional changes rather than neurodegeneration. Further studies will investigate the involvement of these peptides in MS pathogenesis.  相似文献   

6.
We report on the effectiveness of CID, HCD, and ETD for LC-FT MS/MS analysis of peptides using a tandem linear ion trap-Orbitrap mass spectrometer. A range of software tools and analysis parameters were employed to explore the use of CID, HCD, and ETD to identify peptides (isolated from human blood plasma) without the use of specific "enzyme rules". In the evaluation of an FDR-controlled SEQUEST scoring method, the use of accurate masses for fragments increased the number of identified peptides (by ~50%) compared to the use of conventional low accuracy fragment mass information, and CID provided the largest contribution to the identified peptide data sets compared to HCD and ETD. The FDR-controlled Mascot scoring method provided significantly fewer peptide identifications than SEQUEST (by 1.3-2.3 fold) and CID, HCD, and ETD provided similar contributions to identified peptides. Evaluation of de novo sequencing and the UStags method for more intense fragment ions revealed that HCD afforded more contiguous residues (e.g., ≥ 7 amino acids) than either CID or ETD. Both the FDR-controlled SEQUEST and Mascot scoring methods provided peptide data sets that were affected by the decoy database used and mass tolerances applied (e.g., identical peptides between data sets could be limited to ~70%), while the UStags method provided the most consistent peptide data sets (>90% overlap). The m/z ranges in which CID, HCD, and ETD contributed the largest number of peptide identifications were substantially overlapping. This work suggests that the three peptide ion fragmentation methods are complementary and that maximizing the number of peptide identifications benefits significantly from a careful match with the informatics tools and methods applied. These results also suggest that the decoy strategy may inaccurately estimate identification FDRs.  相似文献   

7.
A sensitive and specific method for determination of viaminate in human plasma by using high-performance liquid chromatography coupled with electrospray tandem mass spectrometry (LC-MS/MS) was developed in this study. The plasma samples were simply deproteinated, extracted, evaporated, and then reconstituted in 200 microl of methanol prior to analysis. Chromatographic separation was carried out on a Shimadzu VP-ODS column (250 mm x 2.0 mm, 5 microm) with a mobile phase of methanol-water (95:5, v/v) at a flow rate of 0.2 ml/min. Quantification was performed in the negative-ion electrospray ionization mode by selected ion monitoring of the product ions at m/z 164 for viaminate and m/z 109 for testosterone propionate which was used as the internal standard. The corresponding parent ions were m/z 446 and m/z 345. A linear calibration curve was observed within the concentration range of 0.10-200 ng/ml. The lowest limit of quantitation (LLOQ) was 0.1 ng/ml. The extraction-efficiency at three concentrations was 100.7, 93.6, and 99.7%. Practical utility of this new LC-MS/MS method was confirmed in pilot pharmacokinetic studies in humans following oral administration.  相似文献   

8.
One of the important challenges for MALDI imaging mass spectrometry (MALDI-IMS) is the unambiguous identification of measured analytes. One way to do this is to match tryptic peptide MALDI-IMS m/z values with LC-MS/MS identified m/z values. Matching using current MALDI-TOF/TOF MS instruments is difficult due to the variability of in situ time-of-flight (TOF) m/z measurements. This variability is currently addressed using external calibration, which limits achievable mass accuracy for MALDI-IMS and makes it difficult to match these data to downstream LC-MS/MS results. To overcome this challenge, the work presented here details a method for internally calibrating data sets generated from tryptic peptide MALDI-IMS on formalin-fixed paraffin-embedded sections of ovarian cancer. By calibrating all spectra to internal peak features the m/z error for matches made between MALDI-IMS m/z values and LC-MS/MS identified peptide m/z values was significantly reduced. This improvement was confirmed by follow up matching of LC-MS/MS spectra to in situ MS/MS spectra from the same m/z peak features. The sum of the data presented here indicates that internal calibrants should be a standard component of tryptic peptide MALDI-IMS experiments.  相似文献   

9.
In view of the significance of Asn deamidation and Asp isomerization to isoAsp at certain sites for protein aging and turnover, it was desirable to challenge the extreme analytical power of electrospray tandem mass spectrometry (ESI-MS/MS) for the possibility of a site-specific detection of this posttranslational modification. For this purpose, synthetic L-Asp/L-isoAsp containing oligopeptide pairs were investigated by ESI-MS/MS and low-energy collision-induced dissociation (CID). Replacement of L-Asp by L-isoAsp resulted in the same kind of shifts for all 15 peptide pairs investigated: (1) the b/y intensity ratio of complementary b and y ions generated by cleavage of the (L-Asp/L-isoAsp)-X bond and of the X-(L-Asp/L-isoAsp) bond was decreased, and (2) the Asp immonium ion abundance at m/z 88 was also decreased. It is proposed that the isoAsp structure hampers the accepted mechanism of b-ion formation on both its N- and C-terminal side. The b/y ion intensity ratio and the relative immonium ion intensity vary considerably, depending on the peptide sequence, but the corresponding values are reproducible when recorded on the same instrument under identical instrumental settings. Thus, once the reference product ion spectra have been documented for a pair of synthetic peptides containing either L-Asp or L-isoAsp, these identify one or the other form. Characterization and relative quantification of L-Asp/L-isoAsp peptide mixtures are also possible as demonstrated for two sequences for which isoAsp formation has been described, namely myrG-D/isoD-AAAAK (deamidated peptide 1-7 of protein kinase A catalytic subunit) and VQ-D/isoD-GLR (deamidated peptide 41-46 of human procollagen alpha 1). Thus, the analytical procedures described may be helpful for the identification of suspected Asn deamidation and Asp isomerization sites in proteolytic digests of proteins.  相似文献   

10.
Ceruloplasmin has ferroxidase activity and plays an essential role in iron metabolism. In this study, a site-specific glycosylation analysis of human ceruloplasmin (CP) was carried out using reversed-phase high-performance liquid chromatography with electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS). A tryptic digest of carboxymethylated CP was subjected to LC-ESI-MS/MS. Product ion spectra acquired data-dependently were used for both distinction of the glycopeptides from the peptides using the carbohydrate B-ions, such as m/z 204 (HexNAc) and m/z 366 (HexHexNAc), and identification of the peptide moiety of the glycopeptide based on the presence of the b- and y-series ions derived from the peptide. Oligosaccharide composition was deduced from the molecular weight calculated from the observed mass of the glycopeptide and theoretical mass of the peptide. Of the seven potential N-glycosylation sites, four (Asn119, Asn339, Asn378, and Asn743) were occupied by a sialylated biantennary or triantennary oligosaccharide with fucose residues (0, 1, or 2). A small amount of sialylated tetraantennary oligosaccharide was detected. Exoglycosidase digestion suggested that fucose residues were linked to reducing end GlcNAc in biantennary oligosaccharides and to reducing end and/or alpha1-3 to outer arms GlcNAc in triantennary oligosaccharides and that roughly one of the antennas in triantennary oligosaccharides was alpha2-3 sialylated and occasionally alpha1-3 fucosylated at GlcNAc.  相似文献   

11.
The electron density maps of the catalase-peroxidase from Burkholderia pseudomallei (BpKatG) presented two unusual covalent modifications. A covalent structure linked the active site Trp111 with Tyr238 and Tyr238 with Met264, and the heme was modified, likely by a perhydroxy group added to the vinyl group on ring I. Mass spectrometry analysis of tryptic digests of BpKatG revealed a cluster of ions at m/z 6585, consistent with the fusion of three peptides through Trp111, Tyr238, and Met264, and a cluster at m/z approximately 4525, consistent with the fusion of two peptides linked through Trp111 and Tyr238. MS/MS analysis of the major ions at m/z 4524 and 4540 confirmed the expected sequence and suggested that the multiple ions in the cluster were the result of multiple oxidation events and transfer of CH3-S to the tyrosine. Neither cluster of ions at m/z 4525 or 6585 was present in the spectrum of a tryptic digest of the W111F variant of BpKatG. The spectrum of the tryptic digest of native BpKatG also contained a major ion for a peptide in which Met264 had been converted to homoserine, consistent with the covalent bond between Tyr238 and Met264 being susceptible to hydrolysis, including the loss of the CH3-S from the methionine. Analysis of the tryptic digests of hydroperoxidase I (KatG) from Escherichia coli provided direct evidence for the covalent linkage between Trp105 and Tyr226 and indirect evidence for a covalent linkage between Tyr226 and Met252. Tryptic peptide analysis and N-terminal sequencing revealed that the N-terminal residue of BpKatG is Ser22.  相似文献   

12.
Negative ion fast atom bombardment mass spectrometry (NI-FAB/MS) was employed to characterize the fatty acids esterified to the lipid A backbone of lipopolysaccharides (LPS) of gram-negative bacteria. LPS and their chemically derived lipid A produced readily detectable fragment ions characteristic of fatty acids. The NI-FAB/MS method is specific, yielding ions indicative of ester- but not of amide-bound fatty acids. The mass spectra of Enterobacteriaceae LPS revealed the presence of lauric (m/z 199), myristic (m/z 227), palmitic (m/z 255), and 3-hydroxymyristic (m/z 243) acids. Pseudomonas aeruginosa LPS gave distinctive fragment ions indicative of 3-hydroxydecanoic (m/z 187), lauric, and 2-hydroxylauric (m/z 215) acids. The Neisseria gonorrhoeae LPS could be distinguished from the others due to the presence of ester-linked 3-hydroxylauric acid. All of the LPS gave abundant ions of m/z 177 and 159, which were derived from diphosphoryl substituents. The use of NI-FAB/MS thus allowed rapid identification of lipid A esterified fatty acids without chemical derivatization or gas chromatographic analysis.  相似文献   

13.
A major limitation in identifying peptides from complex mixtures by shotgun proteomics is the ability of search programs to accurately assign peptide sequences using mass spectrometric fragmentation spectra (MS/MS spectra). Manual analysis is used to assess borderline identifications; however, it is error-prone and time-consuming, and criteria for acceptance or rejection are not well defined. Here we report a Manual Analysis Emulator (MAE) program that evaluates results from search programs by implementing two commonly used criteria: 1) consistency of fragment ion intensities with predicted gas phase chemistry and 2) whether a high proportion of the ion intensity (proportion of ion current (PIC)) in the MS/MS spectra can be derived from the peptide sequence. To evaluate chemical plausibility, MAE utilizes similarity (Sim) scoring against theoretical spectra simulated by MassAnalyzer software (Zhang, Z. (2004) Prediction of low-energy collision-induced dissociation spectra of peptides. Anal. Chem. 76, 3908-3922) using known gas phase chemical mechanisms. The results show that Sim scores provide significantly greater discrimination between correct and incorrect search results than achieved by Sequest XCorr scoring or Mascot Mowse scoring, allowing reliable automated validation of borderline cases. To evaluate PIC, MAE simplifies the DTA text files summarizing the MS/MS spectra and applies heuristic rules to classify the fragment ions. MAE output also provides data mining functions, which are illustrated by using PIC to identify spectral chimeras, where two or more peptide ions were sequenced together, as well as cases where fragmentation chemistry is not well predicted.  相似文献   

14.
We present a comprehensive, sensitive, and highly specific negative ion electrospray LC/MS method for identifying all structural classes of glucosinolates in crude plant extracts. The technique is based on the observation of simultaneous maxima in the abundances of the m/z 96 and 97 ions, generated by programmed cone voltage fragmentation, in the mass chromatogram. The abundance ratios lie in the range 1:2-1:4 ([m/z 96]/[m/z 97]). Examination of the corresponding full-scan mass spectra allows individual glucosinolates of all structural classes to be identified rapidly and with confidence. The use of linearly programmed cone voltage fragmentation enhances characteristic fragment ions without compromising the abundance of the analytically important [M - H]- ion and its associated (and analytically useful) sulfur isotope peaks. Detection limits are in the low nanogram range for full-scan, programmed cone voltage spectra. Comparison of the technique with LC/MS/MS methods (product ion, precursor ion, and constant neutral loss scans) has shown that the sensitivity and selectivity of the programmed cone voltage method is superior. Data obtained on a variety of plant extracts confirmed that the methodology was robust and reliable.  相似文献   

15.
Antimicrobial peptides (AMPs) play an important role in the innate immunity of insects. In Drosophila 17 additional immune induced molecules (DIMs) were found in the haemolymph of adult flies upon septic injury. Previous studies using MALDI mass spectrometry combined with Edman degradation, detected AMPs and DIMs of a predominantly large size. By means of 2D-nanoLC ESI MS/MS, 43 DIMs were identified in this study from the haemolymph of Drosophila third instar larvae 12h after challenge with a mixture of Micrococcus luteus and Escherichia coli. Most peptides were derived from known AMP or DIM precursors, but only four peptides were purified and identified before. The majority of the peptides that we detected were smaller in size. Interestingly, two previously unknown peptide precursors were found and hereby related to immune defense. These include CG7738 and CG32185. Many of the identified peptides are post-translationally modified by an N-terminal pyroglutamic acid and/or a C-terminal amide. Haemolymph of control larvae was treated in the same way and revealed only one peptide.  相似文献   

16.
We demonstrate an approach for global quantitative analysis of protein mixtures using differential stable isotopic labeling of the enzyme-digested peptides combined with microbore liquid chromatography (LC) matrix-assisted laser desorption ionization (MALDI) mass spectrometry (MS). Microbore LC provides higher sample loading, compared to capillary LC, which facilitates the quantification of low abundance proteins in protein mixtures. In this work, microbore LC is combined with MALDI MS via a heated droplet interface. The compatibilities of two global peptide labeling methods (i.e., esterification to carboxylic groups and dimethylation to amine groups of peptides) with this LC-MALDI technique are evaluated. Using a quadrupole-time-of-flight mass spectrometer, MALDI spectra of the peptides in individual sample spots are obtained to determine the abundance ratio among pairs of differential isotopically labeled peptides. MS/MS spectra are subsequently obtained from the peptide pairs showing significant abundance differences to determine the sequences of selected peptides for protein identification. The peptide sequences determined from MS/MS database search are confirmed by using the overlaid fragment ion spectra generated from a pair of differentially labeled peptides. The effectiveness of this microbore LC-MALDI approach is demonstrated in the quantification and identification of peptides from a mixture of standard proteins as well as E. coli whole cell extract of known relative concentrations. It is shown that this approach provides a facile and economical means of comparing relative protein abundances from two proteome samples.  相似文献   

17.
The primary structure of two proteins named major latex protein in Arabidopsis thaliana were characterized by matrix-assisted laser desorption/ionization time of flight mass spectrometer and Nano-electrospray ionization tandem mass spectrometry (nanoESI-MS/MS) after two-dimensional gel electrophoresis separation. We revealed that the two proteins with the same N termini and the N-terminal alanine were acetylated after methionine cleavage by fragmentation of three doubly charged peptides using a quadrupole-time of flight 2 tandem mass spectrometer. It was worth noting that one peptide with sodium addition and acetylation was sequenced. It is usually difficult to analyze the peptide sequence of sodium adduct due to the 22-Da increment. The two proteins are highly homologous, and both their N-terminal and C-terminal peptides were sequenced. Of the two proteins, gi|15236568 (spot A) appears only in the seeding stage and flower organ, but gi|15236566 (spot B) appears throughout the whole life of A. thaliana. The biological mechanism of the two proteins and the function of N-terminal acetylation remain to be elucidated. This study showed that ESI-MS/MS was a powerful tool for the characterization of N-terminal acetylation of proteins.  相似文献   

18.
Two-dimensional liquid chromatography (2D-LC) coupled on-line with electrospray ionization tandem mass spectrometry (2D-LC-ESI-MS/MS) is a new platform for analysis and identification of proteome. Peptides are separated by 2D-LC and then performed MS/MS analysis by tandem MS/MS. The MS/MS data are searched against database for protein identification. In one 2D-LC-ESI-MS/MS run, we obtained not only the structural information of peptides directly from MS/MS, but also the retention time of peptides eluted from LC. Information on the chromatographic behavior of peptides can assist protein identification in the new platform for proteomics. The retention time of the matching peptides of the identified protein was predicted by the hydrophobic contribute of each amino acid on reversed-phase liquid chromatography (RPLC). By using this strategy proteins were identified by four types of information: peptide mass fingerprinting (PMF), sequence query, and MS/MS ions searched and the predicted retention time. This additional information obtained from LC could assist protein identification with no extra experimental cost.  相似文献   

19.
Here we report a new method for oxosteroid identification utilizing “tandem mass tag hydrazine” (TMTH) carbonyl-reactive derivatisation reagent. TMTH is a reagent with a chargeable tertiary amino group attached through a linker to a carbonyl-reactive hydrazine group. Thirty oxosteroids were analysed after derivatisation with TMTH by electrospray ionization mass spectrometry (ESI-MS) and were found to give high ion-currents compared to underivatised molecules. ESI-tandem mass spectrometry (MS/MS) analysis of the derivatives yielded characteristic fragmentation patterns with specific mass reporter ions derived from the TMT group. A shotgun ESI-MS method incorporating TMTH derivatisation was applied to a urine sample.  相似文献   

20.
Analysis of free cholesterol (FC) is not well suited for electrospray ionization (ESI); however, cholesteryl ester (CE) form ammonium adducts in positive ion mode and generate a fragment ion of m/z 369 upon collision-induced fragmentation. In order to allow parallel analysis of FC and CE using ESI tandem mass spectrometry (ESI-MS/MS), we developed an acetyl chloride derivatization method to convert FC to cholesteryl acetate (CE 2:0). Derivatization conditions were chosen to provide a quantitative conversion of FC to CE 2:0 without transesterification of naturally occurring CE species. FC and CE were analyzed by direct flow injection analysis using a fragment of m/z 369 in a combination of selected reaction monitoring (SRM) and precursor ion scan for FC and CE, respectively. Quantification was achieved using deuterated D(7)-FC and CE 17:0/CE 22:0 as internal standards as well as calibration lines generated by addition of FC and naturally occurring CE species to the respective sample matrix. The developed assay showed a precision and detection limit sufficient for routine analysis. A run time of 1.3 min and automated data analysis allow high throughput analysis. Loading of human skin fibroblast and monocyte derived macrophages with stable isotope labeled FC showed a potential application of this method in metabolism studies. Together with existing mass spectrometry methodologies for lipid analysis, the present methodology will provide a useful tool for clinical and biochemical studies and expands the lipid spectrum that can be analyzed from one lipid sample on a single instrumental platform.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号