共查询到20条相似文献,搜索用时 0 毫秒
1.
Matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) was used to investigate whole and freeze-thawed Cryptosporidium parvum oocysts. Whole oocysts revealed some mass spectral features. Reproducible patterns of spectral markers and increased sensitivity were obtained after the oocysts were lysed with a freeze-thaw procedure. Spectral-marker patterns for C. parvum were distinguishable from those obtained for Cryptosporidium muris. One spectral marker appears specific for the genus, while others appear specific at the species level. Three different C. parvum lots were investigated, and similar spectral markers were observed in each. Disinfection of the oocysts reduced and/or eliminated the patterns of spectral markers. 相似文献
2.
基质辅助激光解吸电离飞行时间质谱对阪崎肠杆菌的鉴定 总被引:1,自引:0,他引:1
目的 利用基质辅助激光解吸电离飞行时间质谱(MALDI-TOF-MS)法对阪崎肠杆菌进行鉴定,建立一种高效检测阪崎肠杆菌的方法,并为该技术的推广使用及阪崎肠杆菌的进一步研究提供科学依据.方法 用MALDI-TOF-MS法检测38株野生阪崎肠杆菌、2株标准菌株和1株阴沟肠杆菌,结果与常规生化鉴定结果对比;同时对在不同培养基上培养的阪崎肠杆菌进行质谱分析比较,对比不同培养基对质谱结果是否有影响;对38株野生菌株质谱图进行聚类分析.结果 38株菌株鉴定结果均为阪崎肠杆菌,与生化鉴定结果一致,且质谱鉴定分值大多在2.0以上.通过MALDI-TOF-MS鉴定方法可以很明显地将阴沟肠杆菌与阪崎肠杆菌两种菌分开.4种培养基对MALDI-TOF-MS鉴定结果的影响不是很明显,TSA比较适合作为阪崎肠杆菌MALDI-TOF-MS鉴定的培养基.通过质谱图谱和离子峰值比较得出,所有菌株在5745 m/z附近均出现高的离子峰,在2871、4740、8288、6260和9488 m/z附近出现离子峰的实验菌株达95%以上;在差异水平在0.5时,MALDI-TOF-MS的聚类分析结果可将所有实验菌株分成5个类型,结合菌株对应的来源和种类分析表明本研究所用菌株与来源和种类之间并无明显关系.结论 MALDI-TOF-MS方法具有准确且精确鉴定阪崎肠杆菌的能力;离子峰5745m/z具有作为阪崎肠杆菌的标记性离子峰的可能;差异水平为0.5进行MALDI-TOF-MS聚类分析,未发现5个类型与来源等具有一定关系,需要进一步研究. 相似文献
3.
Tarelli E Byers HL Wilson M Roberts G Homer KA Beighton D 《Analytical biochemistry》2000,282(2):165-172
Ribonuclease (RNase) B incubated with purified enzymes, whole bacterial cultures, or their separated components-cells and supernates-have been directly analyzed by matrix-assisted laser desorption/ionization-time of flight mass spectrometry (MALDI-ToF) to detect exomannosidases and to evaluate their specificities and location. Enzymatic cleavage was monitored by observing changes in RNase B glycoform population. Thus a nonspecific alpha-(1 --> 2)-mannosidase activity converts the glycoprotein to its Man(5) form, identifiable by its mass of 14,899 [M + H](+); this species subsequently is converted, by the actions of alpha-(1 --> 3) and alpha-(1 --> 6)-mannosidases, to the Man(1) form via Man(4), Man(3), and Man(2). The Man(1) glycoform (which is readily isolated) has then similarly been used for identifying beta-(1 --> 4)-mannosidase and the derived Man(0) form has served in turn as a natural substrate for beta-(1 --> 4) N-acetylglucosaminidase producing a species possessing a single asparagine-linked GlcNAc residue (mass 13,886). Mannose liberated from the actions of mannosidases can, if desired, be quantified by, for example, chromatography. The actions and specificities of endoglycosidases such as a peptide-N-glycosidase F (PNGase F) and of endo-N-acetlyglucosaminidases (e.g., endo-F and endo-H), which respectively cleave between the GlcNAc&bond;Asn and GlcNAc&bond;GlcNAc bonds of N-linked glycoproteins, are also demonstrable by MALDI-ToF analysis of RNase B (and derived products). From these digests the completely deglycosylated polypeptide corresponding to RNase A in which Asn has been converted to Asp (mass 13,684) and a species corresponding to RNase A + GlcNAc (mass 13,886) are produced, together with their corresponding free oligosaccharides which are amenable to analysis by both MALDI-ToF and by HPLC. 相似文献
4.
Harvey DJ 《Proteomics》2005,5(7):1774-1786
This paper reviews methods for the analysis of N-linked glycans by mass spectrometry with emphasis on studies conducted at the Oxford Glycobiology Institute. Topics covered are the release of glycans from sodium dodecyl sulphate-polyacrylamide gel electrophoresis gels, their purification for analysis by mass spectrometry, methods based on matrix-assisted laser desorption/ionization (MALDI) and electrospray ionization for producing fragment ions, and details of their fragmentation. MALDI mass spectrometry provided a rapid method for profiling neutral N-linked glycans as their [M + Na](+) ions which could be fragmented by collision-induced decomposition to give spectra containing both glycosidic and cross-ring fragments. Electrospray ionization mass spectrometry was more versatile in that it was relatively easy to change the type of ion that was formed and, furthermore, unlike MALDI, electrospray did not cause extensive loss of sialic acids from sialylated glycans. Negative ions formed by addition of anions such as chloride and, particularly, nitrate, to the electrospray solvent were stable and enabled singly charged ions to be obtained from larger glycans than was possible in positive ion mode. Fragmentation of negative ions followed specific pathways that defined structural details of the glycans that were difficult to obtain by classical methods such as exoglycosidase digestion. 相似文献
5.
Hindré T Didelot S Le Pennec JP Haras D Dufour A Vallée-Réhel K 《Applied and environmental microbiology》2003,69(2):1051-1058
Class I bacteriocins (lantibiotics) and class II bacteriocins are antimicrobial peptides secreted by gram-positive bacteria. Using two lantibiotics, lacticin 481 and nisin, and the class II bacteriocin coagulin, we showed that bacteriocins can be detected without any purification from whole producer bacteria grown on plates by matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF-MS). When we compared the results of MALDI-TOF-MS performed with samples of whole cells and with samples of crude supernatants of liquid cultures, the former samples led to more efficient bacteriocin detection and required less handling. Nisin and lacticin 481 were both detected from a mixture of their producer strains, but such a mixture can yield additional signals. We used this method to determine the masses of two lacticin 481 variants, which confirmed at the peptide level the effect of mutations in the corresponding structural gene. 相似文献
6.
In view of the fact that memory effects associated with instrument calibration hinder the use of many mass-to-charge (m/z) ratios and tuning standards, identification of robust, comprehensive, inexpensive, and memory-free calibration standards is of particular interest to the mass spectrometry community. Glucose and its isomers are known to have a residue mass of 162.05282 Da; therefore, both linear and branched forms of polyhexose oligosaccharides possess well-defined masses, making them ideal candidates for mass calibration. Using a wide range of maltooligosaccharides (MOSs) derived from commercially available beers, ions with m/z ratios from approximately 500 to 2500 Da or more have been observed using Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR-MS) and time-of-flight mass spectrometry (TOF-MS). The MOS mixtures were further characterized using infrared multiphoton dissociation (IRMPD) and nano-liquid chromatography/mass spectrometry (nano-LC/MS). In addition to providing well-defined series of positive and negative calibrant ions using either electrospray ionization (ESI) or matrix-assisted laser desorption/ionization (MALDI), the MOSs are not encumbered by memory effects and, thus, are well-suited mass calibration and instrument tuning standards for carbohydrate analysis. 相似文献
7.
Bernardo K Pakulat N Macht M Krut O Seifert H Fleer S Hünger F Krönke M 《Proteomics》2002,2(6):747-753
Staphylococcus aureus is an important human pathogen frequently resistant to a wide range of antibiotics. Methicillin-resistant S. aureus (MRSA) strains are common nosocomial pathogens that pose a world-wide problem. Rapid and accurate discrimination between methicillin-sensitive S. aureus (MSSA) and methicillin-resistant S. aureus is essential for appropriate therapeutic management and timely intervention for infection control. We report here the application of matrix-assisted laser desorption/ionization-time of flight mass spectrometry (MALDI-TOF MS) for monitoring the bacterial fingerprints expressed by two well characterized S. aureus strains ATCC 29213 (MSSA) and ATCC 43330 (MRSA). Consistent strain-specific data were obtained from subcultures analyzed over a period of three months as well as after changing the growth media from Mueller-Hinton to blood agar indicating the reliability of the method. The bacterial fingerprints of these two strains were compared to independent clinical isolates of S. aureus. A uniform signature profile for MRSA could not be identified. However, the bacterial fingerprints obtained proved to be specific for any given strain. This study demonstrates that MALDI-TOF MS is a powerful method for rapid identification of clonal strains of S. aureus, which might be useful for tracking nosocomial outbreaks of MRSA and for epidemiologic studies of infections diseases in general. 相似文献
8.
In addition to protein identification, characterization of post-translational modifications (PTMs) is an essential task in proteomics. PTMs represent the major reason for the variety of protein isoforms and they can influence protein structure and function. Upon matrix-assisted laser desorption/ionization (MALDI) most post-translationally modified peptides form a fraction of labile molecular ions, which lose PTM-specific residues only after acceleration. Compared to fully accelerated ions these fragment ions are defocused and show in reflector mass spectra reduced resolution. A short time Fourier transform using a Hanning window function now uses this difference in resolution to detect the metastable fragments. Its application over the whole mass range yields frequency distributions and amplitudes as a function of mass, where an increased low frequency proportion is highly indicative for metastable fragments. Applications on the detection of metastable losses originating from carboxamidomethylated cysteines, oxidized methionines, phosphorylated and glycosylated amino acid residues are presented. The metastable loss of mercaptoacetamide detected with this procedure represents a new feature and its integration in search algorithms will improve the specificity of MALDI peptide mass fingerprinting. 相似文献
9.
Among many methods used to investigate protein/protein interactions, chemical cross-linking combined with mass spectrometry remains a vital experimental approach. Mapping peptides modified by cross-linker provides clues about proteins’ interacting domains. One complication is that such modification may result from intra- but not intermolecular interactions. Therefore, for overall data interpretation, a combination of results from various platforms is necessary. It is postulated that the secretory isoform of gelsolin regulates several biological processes through interactions with proteins such as actin, fibronectin, vitamin D-binding protein, and unidentified receptors on the surface of eukaryotes; it also has been shown to self-assemble eventually leading to the formation of homo-multimers. As such, it is an excellent model for this study. We used four cross-linkers with arm length ranging from 7.7 to 21.7 Å and MALDI-TOF/TOF mass spectrometry as the analytical platform. Results of this study show that MALDI-based mass spectrometry generates high quality data to show lysine residues modified by cross-linkers and combined with existing data based on crystallography (Protein Data Bank, PDB) can be used to discriminate between inter- and intramolecular linking. 相似文献
10.
【目的】糖丝菌属(Saccharothrix)是一类丝状稀有放线菌,在生物医药、工业酶制剂和环境修复等领域展现出应用价值。本研究尝试建立以核糖体蛋白质为标志物,利用基质辅助激光解吸电离飞行时间质谱(matrix-assisted laser desorption/ionization-time of flight mass spectrometry,MALDI-TOF MS)技术鉴定糖丝菌属放线菌的方法。【方法】检索基因组数据库,提取糖丝菌属测序菌株15种核糖体蛋白质的序列并计算理论分子量;通过分子量比对分析糖丝菌属不同菌种之间及其模式菌株与邻近属菌种模式菌株之间15种核糖体蛋白质的匹配度,提出鉴定至菌种及属的核糖体蛋白质匹配数标准;选取目标属和非目标属菌种进行MALDI-TOF MS测试和分析并修正鉴定标准。【结果】将待测菌株的MALDI-TOF质谱峰与糖丝菌属各菌种模式菌株的15种核糖体蛋白质分别匹配,通过最大匹配数、质谱峰强度模式及特征质谱峰鉴定至属或种。【结论】本研究建立了基于15种核糖体蛋白质标志物及MALDI-TOF MS技术鉴定糖丝菌属放线菌的方法,可用于定向筛选和快速鉴... 相似文献
11.
It has become evident that the mystery of life will not be deciphered just by decoding its blueprint, the genetic code. In the life and biomedical sciences, research efforts are now shifting from pure gene analysis to the analysis of all biomolecules involved in the machinery of life. One area of these postgenomic research fields is proteomics. Although proteomics, which basically encompasses the analysis of proteins, is not a new concept, it is far from being a research field that can rely on routine and large-scale analyses. At the time the term proteomics was coined, a gold-rush mentality was created, promising vast and quick riches (i.e., solutions to the immensely complex questions of life and disease). Predictably, the reality has been quite different. The complexity of proteomes and the wide variations in the abundances and chemical properties of their constituents has rendered the use of systematic analytical approaches only partially successful, and biologically meaningful results have been slow to arrive. However, to learn more about how cells and, hence, life works, it is essential to understand the proteins and their complex interactions in their native environment. This is why proteomics will be an important part of the biomedical sciences for the foreseeable future. Therefore, any advances in providing the tools that make protein analysis a more routine and large-scale business, ideally using automated and rapid analytical procedures, are highly sought after. This review will provide some basics, thoughts and ideas on the exploitation of matrix-assisted laser desorption/ ionization in biological mass spectrometry - one of the most commonly used analytical tools in proteomics - for high-throughput analyses. 相似文献
12.
《Expert review of proteomics》2013,10(3):407-420
It has become evident that the mystery of life will not be deciphered just by decoding its blueprint, the genetic code. In the life and biomedical sciences, research efforts are now shifting from pure gene analysis to the analysis of all biomolecules involved in the machinery of life. One area of these postgenomic research fields is proteomics. Although proteomics, which basically encompasses the analysis of proteins, is not a new concept, it is far from being a research field that can rely on routine and large-scale analyses. At the time the term proteomics was coined, a gold-rush mentality was created, promising vast and quick riches (i.e., solutions to the immensely complex questions of life and disease). Predictably, the reality has been quite different. The complexity of proteomes and the wide variations in the abundances and chemical properties of their constituents has rendered the use of systematic analytical approaches only partially successful, and biologically meaningful results have been slow to arrive. However, to learn more about how cells and, hence, life works, it is essential to understand the proteins and their complex interactions in their native environment. This is why proteomics will be an important part of the biomedical sciences for the foreseeable future. Therefore, any advances in providing the tools that make protein analysis a more routine and large-scale business, ideally using automated and rapid analytical procedures, are highly sought after. This review will provide some basics, thoughts and ideas on the exploitation of matrix-assisted laser desorption/ ionization in biological mass spectrometry – one of the most commonly used analytical tools in proteomics – for high-throughput analyses. 相似文献
13.
14.
Williamson YM Moura H Woolfitt AR Pirkle JL Barr JR Carvalho Mda G Ades EP Carlone GM Sampson JS 《Applied and environmental microbiology》2008,74(19):5891-5897
Streptococcus pneumoniae (pneumococcus [Pnc]) is a causative agent of many infectious diseases, including pneumonia, septicemia, otitis media, and conjunctivitis. There have been documented conjunctivitis outbreaks in which nontypeable (NT), nonencapsulated Pnc has been identified as the etiological agent. The use of mass spectrometry to comparatively and differentially analyze protein and peptide profiles of whole-cell microorganisms remains somewhat uncharted. In this report, we discuss a comparative proteomic analysis between NT S. pneumoniae conjunctivitis outbreak strains (cPnc) and other known typeable or NT pneumococcal and streptococcal isolates (including Pnc TIGR4 and R6, Streptococcus oralis, Streptococcus mitis, Streptococcus pseudopneumoniae, and Streptococcus pyogenes) and nonstreptococcal isolates (including Escherichia coli, Enterococcus faecalis, and Staphylococcus aureus) as controls. cPnc cells and controls were grown to mid-log phase, harvested, and subsequently treated with a 10% trifluoroacetic acid-sinapinic acid matrix mixture. Protein and peptide fragments of the whole-cell bacterial isolate-matrix combinations ranging in size from 2 to 14 kDa were evaluated by matrix-assisted laser desorption ionization-time of flight mass spectrometry. Additionally Random Forest analytical tools and dendrogramic representations (Genesis) suggested similarities and clustered the isolates into distinct clonal groups, respectively. Also, a peak list of protein and peptide masses was obtained and compared to a known Pnc protein mass library, in which a peptide common and unique to cPnc isolates was tentatively identified. Information gained from this study will lead to the identification and validation of proteins that are commonly and exclusively expressed in cPnc strains which could potentially be used as a biomarker in the rapid diagnosis of pneumococcal conjunctivitis. 相似文献
15.
Low molecular weight glutenin subunits (LMW-GS) are typically subdivided into three groups, according to their molecular weights and isoelectric points, namely the B-, C-, and D groups. Enriched B- and C-type LMW-GS fractions extracted from the bread wheat cultivar Chinese Spring were characterized using high performance liquid chromatography (HPLC) directly interfaced with electrospray ionization mass spectrometry and HPLC coupled off-line with matrix-assisted laser desorption/ionization mass spectrometry, in order to ascertain the number and relative molecular masses of the components present in each fraction and determine the number of cysteine residues. About 70 components were detected in each of the fractions examined by the combined use of these two techniques, with 18 components common to both fractions. Analysis of the fractions after alkylation with 4-vinylpyridine allowed determination of the number of the cysteines present in about 40 subunits. The proteins detected were tentatively classified based on the relative molecular masses and number of cysteine residues. Cross-contamination was found in both B- and C- fractions, along with the presence of D-type LMW-GS. The two fractions also contained unexpected components, probably lipid transfer proteins and omega-gliadins. The presence of extensive microheterogeneity was suggested by the detection of several co-eluting proteins with minor differences in their molecular masses. 相似文献
16.
Biroccio A Urbani A Massoud R di Ilio C Sacchetta P Bernardini S Cortese C Federici G 《Analytical biochemistry》2005,336(2):279-288
The quantization of glycated isoforms of hemoglobin has been increasingly used in clinical practice in recent years. Glycated hemoglobin is currently considered the most important measurement for long-term control of the glycemic state and it has become a reference tool for the management of diabetes. Glutathionylated hemoglobin is an increasingly clinically relevant covalent adduct of glutathione with beta chain of the globin and its concentration has been correlated with oxidative stress. We have developed an innovative technique based on linear mode matrix-assisted laser desorption ionization-time of flight (MALDI-TOF) mass spectrometry for quantitative analysis of hemoglobin species. This method was applied to the quantification of glycated and glutathionylated hemoglobin. A rigorous comparison was pursued to evaluate the analytical performances in quantifying glycated hemoglobin in comparison to an established high-performance liquid chromatography method. Our results indicated a complete equivalence between the two methods. The same analysis enabled the quantitative determination of the glutathionylated hemoglobin fraction. This isoform was investigated in an adult Italian population (184 individuals, 101 males and 83 females), indicating a bimodal distribution of this species. In fact 65.22% of screened individuals had glutathionylated hemoglobin levels lower than 0.50% while 34.78% had glutathionylated hemoglobin levels higher than 0.50%. A semiautomatic robotic procedure was developed for fast analysis of a large number of samples. This is the first report of a quantitative application of linear MALDI-TOF mass spectrometry for the determination of glutathionylated hemoglobin in blood samples. This method allows fast screening of this hemoglobin isoform, therefore opening the route to explore its specificity and sensitivity as a molecular biomarker. 相似文献
17.
We report a method to detect the presence of dimethylarginines on proteins. Peptides with dimethylarginines were hydrolyzed in acid. The hydrolysates were subjected to matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometric analysis using a mixture of alpha-cyano-4-hydroxycinnamic acid and nitrocellulose as matrix. Both asymmetric omega-N(G),N(G)-dimethylarginine and symmetric omega-N(G),N(G')-dimethylarginine give a clear signal at m/z 203. Recombinant Sbp1p modified by Hmt1p in vivo were isolated by affinity chromatography followed by electrophoresis on a polyacrylamide gel and subjected to acid hydrolysis. MALDI-TOF analysis of the acid hydrolysates confirmed the presence of dimethylarginines. The detection limit of the method is estimated at approximately 1pmol of protein. 相似文献
18.
19.
Kempf M Bakour S Flaudrops C Berrazeg M Brunel JM Drissi M Mesli E Touati A Rolain JM 《PloS one》2012,7(2):e31676
Rapid detection of carbapenem-resistant Acinetobacter baumannii strains is critical and will benefit patient care by optimizing antibiotic therapies and preventing outbreaks. Herein we describe the development and successful application of a mass spectrometry profile generated by matrix-assisted laser desorption ionization-time of flight (MALDI-TOF) that utilized the imipenem antibiotic for the detection of carbapenem resistance in a large series of A. baumannii clinical isolates from France and Algeria. A total of 106 A. baumannii strains including 63 well-characterized carbapenemase-producing and 43 non-carbapenemase-producing strains, as well as 43 control strains (7 carbapenem-resistant and 36 carbapenem-sensitive strains) were studied. After an incubation of bacteria with imipenem for up to 4 h, the mixture was centrifuged and the supernatant analyzed by MALDI-TOF MS. The presence and absence of peaks representing imipenem and its natural metabolite was analyzed. The result was interpreted as positive for carbapenemase production if the specific peak for imipenem at 300.0 m/z disappeared during the incubation time and if the peak of the natural metabolite at 254.0 m/z increased as measured by the area under the curves leading to a ratio between the peak for imipenem and its metabolite being <0.5. This assay, which was applied to the large series of A. baumannii clinical isolates, showed a sensitivity of 100.0% and a specificity of 100.0%. Our study is the first to demonstrate that this quick and simple assay can be used as a routine tool as a point-of-care method for the identification of A. baumannii carbapenemase-producers in an effort to prevent outbreaks and the spread of uncontrollable superbugs. 相似文献
20.
High detection sensitivity and resolution are two critical parameters for recording good peptide mass fingerprints (PMF) of low abundance proteins. This paper reports a mass spectrometry (MS) sample preparation technique that could improve sensitivity and resolution. By coating the MS steel target with a thin layer of pentadecafluorooctamido propyltrimethoxysilane, which was both polar and nonpolar solvent repellent, the transferred sample droplets on its surface were significantly smaller. As a result, the analyte of the peptide mixture became more concentrated and homogeneous, which helped to improve the sensitivity. The advantages of a modified MS target were documented by mass spectra improvement of attomole level standard peptides and silver-stained proteins from polyacrylamide gels. The mass signal of angiotensin II at 100 attomole was difficult to record on the conventional support, whereas it was easily detected on the modified one. The PMF of cytochrome C was also better recorded on the modified support, in terms of both signal-to-noise ratio and the number of detected peptides. When silver-stained proteins from two-dimensional electrophoresis gels were analyzed, in most cases more satisfactory peptide mass spectra were obtained from the modified support. Searching protein databases with more mass data from the improved PMFs, several unknown proteins were successfully identified. 相似文献