首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.

Background

Atrial fibrillatory cycle length has been considered one of the indices of atrial electrical remodelling during atrial fibrillation (AF), which can be assessed from surface ECG by computer-assisted calculation of atrial fibrillatory rate (AFR). Horses have been suggested as a bona fide model for AF studies since horses too, develop lone AF, however data on AF characteristics in horses are extremely sparse and non-invasive characterization of AF complexity using surface ECG processing has not been reported.

Aim

The aim was to study characteristics of induced AF and its modification by flecainide.

Methods

The study group consisted on 3 horses with spontaneous persistent AF and 13 with pace-induced AF. Seven horses were treated with saline (control) and eight with flecainide (2 mg/kg). ECGs were analysed using spatiotemporal cancellation of QRST complexes and calculation of AFR from the residual atrial signal.

Results

At AF onset, AFR was 295?±?52 fibrillations per minute (fpm) in the horses with induced AF treated with flecainide, 269?±?36 fpm in the control group (ns), and 364?±?26 fpm in the horses with spontaneous persistent AF (P?<?0.05 compared to the control group). Flecainide caused a decrease in AFR in all animals and restored sinus rhythm in the animals with induced AF. In the control animals, AFR increased from 269?±?36 fpm to a plateau of 313?±?14 fpm before decreasing to 288?±?28 fpm during the last 10% of the AF episodes preceding spontaneous conversion (P?<?0.05).

Conclusion

AFR in horses with induced AF resembles AFR in humans with paroxysmal AF. Flecainide caused a rapid decrease in AFR in all horses, further supporting the method to be a non-invasive technique to study the effect of antiarrhythmic compounds.
  相似文献   

2.

Background

The prognostic significance of paced QRS complex morphology on surface ECG remains unclear. This study aimed to assess long-term outcomes associated with variations in the paced QRS complex.

Methods

Adult patients who underwent dual-chamber pacemaker implantation with 20% or more ventricular pacing and a 12-lead ECG showing a paced complex were included. The paced QRS was analyzed in leads I and aVL. Long-term clinical and echocardiographic outcomes were compared at 5 years.

Results

The study included 844 patients (43.1% female; age 75.0?±?12.1). Patients with a longer paced QRS (pQRS) duration in lead I had a lower rate of atrial fibrillation (HR 0.80; p?=?0.03) and higher rate of systolic dysfunction (HR 1.17; p?<?0.001). Total pacing complex (TPC) duration was linked to higher rates of ICD implantation (HR 1.18; p?=?0.04) and systolic dysfunction (HR 1.22, p?<?0.001). Longer paced intrinsicoid deflection (pID) was associated with less atrial fibrillation (HR 0.75; p?=?0.01), more systolic dysfunction (HR 1.17; p?<?0.001), ICD implantation (HR 1.23; p?=?0.04), and CRT upgrade (HR 1.23; p?=?0.03). Exceeding thresholds for TPC, pQRS, and pID of 170, 146, and 112?ms in lead I, respectively, was associated with a substantial increase in systolic dysfunction over 5 years (p?<?0.001).

Conclusions

Longer durations of all tested parameters in lead I were associated with increased rates of left ventricular systolic dysfunction. ICD implantation and CRT upgrade were also linked to increased TPC and pID durations. Paradoxically, patients with longer pID and pQRS had less incident atrial fibrillation.  相似文献   

3.

Background

Cryoballoon-based pulmonary vein isolation (PVI) is a treatment option for atrial fibrillation (AF). Left atrial volume (LAV) and left atrial volume index (LAVi) are important parameters for long term success of PVI. Galectin-3 (Gal-3) and neutrophil to lymphocyte ratio (N/L ratio) are biomarkers to demonstrate the cardiac fibrosis and remodelling.

Methods

50 patients with symptomatic PAF despite ≥1 antiarrhythmic drug(s), who underwent PVI were enrolled. LAV, LAVi, Gal-3 and N/L ratio were calculated before ablation and after ablation at 6 and 12 months. According to AF recurrence patients were divided into two groups, recurrent AF (n?=?14) and non-recurrent AF (n?=?36).

Results

In both groups (recurrent and non-recurrent), initial and 12 months follow-up LAV values were 41.39?±?18.13?ml and 53.24?±?22.11?ml vs 48.85?±?12.89?ml and 42.08?±?13.85 (p?=?0.037). LAVi were 20.9?±?8.91 ml/m2 and 26.85?±?11.28 ml/m2 vs 25.36?±?6.21 and 21.87?±?6.66 (p?=?0.05) for recurrent and non-recurrent AF groups, respectively. In both groups PVI had no significant effect on serum Gal-3 levels and N/L ratio during 12 months follow-up. The comparison between two groups at the end of 12th month showed Gal-3 values of 6.66?±?4.09?ng/ml and 6.02?±?2.95?ng/ml (p?=?0.516), N/L ratio values of 2.28?±?1.07 103/μl and 1.98?±?0.66?103/μl (p?=?0.674).

Conclusion

LAV and LAVi are useful to predict the remodelling of the left atrium and AF recurrence after cryoballoon-based PVI. However, biomarkers such as Gal-3 and N/L ratio are not associated with AF recurrence.  相似文献   

4.

Background

Good and reliable atrial sensing is a fundamental part of atrioventricular (AV) synchrony in dual chamber pacemakers. Due to the floating nature of atrial sensing electrode in single pass dual chamber pacemakers (VDD) compared with two-lead dual chamber pacemakers (DDD), they are more prone to atrial under-sensing and the resulting loss of AV synchrony. We hypothesized that there is a relation between the chronicity of AV block and the amplitude of intracardiac atrial signal amplitudes (IASA).

Methods

Detailed demographic, electrocardiographic and echocardiographic data were recorded in 34 consecutive patients with congenital and acquired complete heart block (CHB). The intracardiac atrial signal amplitudes (IASA) were recorded at implantation time, 48 hours and 2 months post-implantation and compared between the two groups of patients.

Results

The mean age of the study group was 38.73±12.53 years (congenital: 30.08±11.07, acquired: 47.38±6.5). There were no important differences in left atrial or ventricular sizes and in P-wave amplitude in lead II, but the IASA was significantly higher in the congenital group at implantation time (5.21±1.86 vs. 3.38±0.84 mV, P<0.001) and during the follow-up.

Conclusion

The intracardiac atrial signal amplitudes were higher in congenital CHB compared with the acquired CHB. Chronicity (and may be the congenital type) of CHB may be an affecting factor in case selection for VDD pacemaker implantation.  相似文献   

5.

Background

Third-generation cryoballoon (CB3) is characterized by a 40% shorter distal tip designed to increase the rate of pulmonary veins real-time signal recording in order to measure time necessary to isolate veins, the “Time to effect” (TTE). Few data are currently available on clinical follow up of CB3 treated patients.

Methods

Sixtyeight consecutive patients (mean age 57.8?±?9.6 years, 48 male) with paroxysmal or persistent atrial fibrillation (AF) were enrolled. Thirthyfour (25 paroxysmal AF) underwent to a 28 mmCB3 pulmonary veins isolation and were compared to 34 treated (21 paroxysmal AF) with 28 mmCB2.

Results

CB3 use was correlated to significant increase of the possibility to measure TTE in every treated veins (left superior 82,35% vs 23,53%, left inferior 70,59% vs 38,24%, right superior 58,82% vs 14,71%, right inferior 52,94% vs 17,65%). When it is measured, TTE wasn't different between two groups. Higher nadir temperature was observed in CB3 patients (?39.4?±?5.2?°C vs ?43.0?±?7.2?°C, p?=?0.03). CB3 procedures were shorter (91.4?±?21.7 vs 110.9?±?31.8?min, p?=?0.018), with a significant reduction in cryoenergy delivery time (24.2?±?8.5 vs 20.3?±?6.7?min, p?<?0.05), and a significant reduction in left atrium dwell time (59.3?±?9.8 vs 69.3?±?10.8?min, p?=?0.02, p?<?0.05). At one year follow up period the Kaplan-Meier curve didn't show any significant difference in AF-free survival (Log p?=?0,49).

Conclusions

Novel CB3 is a useful tool in order to simplify AF cryoballoon ablation when compared to second generation cryoballoon, as observed in our experience. Follow up data seem confirm a clinical CB3 efficacy at least comparable CB2.  相似文献   

6.

Introduction

Catheter ablation of longstanding (> 1 year) persistent atrial fibrillation (AF) is associated with poor outcome. This might be due to remodelling and fibrosis formation, mainly located in the posterior left atrial (LA) wall. Therefore, we adopted a thoracoscopic epicardial box isolation of the posterior left atrium using bipolar RF energy with intraoperative testing of conduction block.

Methods and results

Bilateral thoracoscopic box isolation was performed with a bipolar RF clamp. Entrance block was defined as absence of a conducted electrogram within the box, while exit block was confirmed by pacing at 10.0 V/2 ms. Ablation outcome was evaluated after 3, 6, 12 and 24 months with 12-lead ECGs and 24-hour Holter recordings.Twenty-five consecutive patients were included (58 ± 7 years, persistent AF duration 1.8 ± 0.9 years). Entrance block was achieved in all patients and exit block confirmed if sinus rhythm was achieved. After 17 ± 7 months, 76 % of the patients (n = 19) were free of AF recurrence. One patient died within 1 month and was considered an ablation failure. Four patients with AF recurrences regained sinus rhythm with additional catheter ablation or antiarrhythmic drugs.

Conclusions

Treatment of longstanding persistent AF with thoracoscopic epicardial LA posterior box isolation using bipolar RF energy with intraoperative testing of conduction block is feasible and highly effective.  相似文献   

7.

Background

Pulmonary hypertension (PH) is associated with progressive impairment of right ventricular function, reduced exercise capacity and a poor prognosis. Little is known about the prevalence, clinical manifestation and impact of atrial fibrillation (AF) on cardiac function in PH.

Methods

In a four year single-centre retrospective analysis 225 patients with confirmed PH of various origins were enrolled to investigate the prevalence of AF, and to assess the clinical manifestation, 6-minute walk distance, NT-proBNP levels, echocardiographic parameters and hemodynamics obtained by right heart catheterization in PH with AF.

Results

AF was prevalent in 31.1%. In patients with PH and AF, parameters of clinical deterioration (NYHA/WHO functional class, 6-minute walk distance, NT-proBNP levels) and renal function were significantly compromised compared to patients with PH and sinus rhythm (SR). In the total PH cohort and in PH not related to left heart disease occurrence of AF was associated with an increase of right atrial pressure (RAP) and right atrial dilatation. While no direct association was found between pulmonary artery pressure (PAP) and AF in these patients, right ventricular function was reduced in AF, indicating more advanced disease. In PH due to left heart failure the prevalence of AF was particularly high (57.7% vs. 23.1% in other forms of PH). In this subgroup, left atrial dilatation, increase of pulmonary capillary wedge pressure, PAP and RAP were more pronounced in AF than in SR, suggesting that more marked backward failure led to AF in this setting.

Conclusion

PH is associated with increased prevalence of AF. Occurrence of AF in PH indicates clinical deterioration and more advanced disease.  相似文献   

8.

Background

Atrial fibrillation (AF) is the most common arrhythmia encountered in clinical practice. Elective electrical cardioversion is often performed in patients with persistent AF to attempt sinus rhythm (SR) restoration. However, AF recurrences are frequent after successful cardioversion and several predictors have been identified.

Aim of the study

The present study was designed to prospectively analyse the correlation between NT-pro-BNP levels and AF recurrence in consecutive patients referred for electrical cardioversion of persistent atrial fibrillation.

Results

Forty consecutive patients referred for elective cardioversion of AF were enrolled in the study. Cardioversion restored sinus rhythm in 34/40 patients but 2 of them presented an early recurrence of AF before discharge. Patients were then followed for 6 months to assess AF recurrence. Cox regression analysis was performed using the parameters found predictive on univariate survival analysis (NT-pro-BNP quartiles, beta-blockers). The only independent predictor of AF recurrence on Cox-regression analysis was a level of NT-pro-BNP in the fourth quartile (HR 3.21 95%CI 1.26-8.14, p=0.014). On receiver operating curve (ROC) analysis, NT-pro-BNP levels above 1707 pg/ml had a specificity of 92% (and a sensitivity of 36%) in predicting atrial fibrillation recurrence by 6 months.

Conclusions

Baseline NT-pro-BNP levels are an independent predictor of AF recurrence at 6 months follow-up in candidates for elective direct current cardioversion.  相似文献   

9.
10.

Background

Atrial electrical remodeling has been shown to influence the outcome the outcome following cardioversion of atrial fibrillation (AF) in experimental studies. The aim of the present study was to find out whether a non-invasively measured atrial fibrillatory cycle length, alone or in combination with other non-invasive parameters, could predict sinus rhythm maintenance after cardioversion of AF.

Methods

Dominant atrial cycle length (DACL), a previously validated non-invasive index of atrial refractoriness, was measured from lead V1 and a unipolar oesophageal lead prior to cardioversion in 37 patients with persistent AF undergoing their first cardioversion.

Results

32 patients were successfully cardioverted to sinus rhythm. The mean DACL in the 22 patients who suffered recurrence of AF within 6 weeks was 152 ± 15 ms (V1) and 147 ± 14 ms (oesophagus) compared to 155 ± 17 ms (V1) and 151 ± 18 ms (oesophagus) in those maintaining sinus rhythm (NS). Left atrial diameter was 48 ± 4 mm and 44 ± 7 mm respectively (NS). The optimal parameter predicting maintenance of sinus rhythm after 6 weeks appeared to be the ratio of the lowest dominant atrial cycle length (oesophageal lead or V1) to left atrial diameter. This ratio was significantly higher in patients remaining in sinus rhythm (3.4 ± 0.6 vs. 3.1 ± 0.4 ms/mm respectively, p = 0.04).

Conclusion

In this study neither an index of atrial refractory period nor left atrial diameter alone were predictors of AF recurrence within the 6 weeks of follow-up. The ratio of the two (combining electrophysiological and anatomical measurements) only slightly improve the identification of patients at high risk of recurrence of persistent AF. Consequently, other ways to asses electrical remodeling and / or other variables besides electrical remodeling are involved in determining the outcome following cardioversion.  相似文献   

11.

Aims

Atrial fibrillation (AF) and heart failure are conditions that often coexist. Consequently, many patients with an implantable cardioverter-defibrillator (ICD) present with AF. We evaluated the effectiveness of internal cardioversion of AF in patients with an ICD.

Methods

Retrospectively, we included 27 consecutive ICD patients with persistent AF who underwent internal cardioversion using the ICD. When ICD cardioversion failed, external cardioversion was performed.

Results

Patients were predominantly male (89 %) with a mean (SD) age of 65 ± 9 years and left ventricular ejection fraction of 36 ± 17 %. Only nine (33 %) patients had successful internal cardioversion after one, two or three shocks. The remaining 18 patients underwent external cardioversion after they failed internal cardioversion, which resulted in sinus rhythm in all. A smaller left atrial volume (99 ± 36 ml vs. 146 ± 44 ml; p = 0.019), a longer right atrial cycle length (227 (186–255) vs. 169 (152–183) ms, p = 0.030), a shorter total AF history (2 (0–17) months vs. 40 (5–75) months, p = 0.025) and dual-coil ICD shock (75 % vs. 26 %, p = 0.093) were associated with successful ICD cardioversion.

Conclusion

Internal cardioversion of AF in ICD patients has a low success rate but may be attempted in those with small atria, a long right atrial fibrillatory cycle length and a short total AF history, especially when a dual-coil ICD is present. Otherwise, it seems reasonable to prefer external over internal cardioversion when it comes to termination of persistent AF.  相似文献   

12.

Background

Timely detection of atrial fibrillation (AF) in implantable cardioverter defibrillator (ICD) patients is clinically important for prevention of AF-related complications and inappropriate shocks. Patients with coronary artery disease (CAD) and a dual or triple chamber ICD show a high incidence of device-detected AF. Whether CAD patients with a single chamber ICD carry a similar risk for device-detected AF remains unknown.

Study design

The INDICO AF trial is an investigator-initiated, multicentre, observational study evaluating the incidence of subclinical AF (SCAF) in CAD patients who will receive a single chamber ICD as primary prevention for sudden cardiac death (SCD). Fifty patients will receive a single chamber ICD with an integrated RR interval based AF detection algorithm. In combination with remote monitoring, rhythm data will be collected monthly. The primary endpoint is the incidence of SCAF at 1 year of follow-up; secondary endpoints include time until 10 and 20% of the patients have a first episode of SCAF. All patients in whom SCAF is detected will be invited for an outpatient visit and will receive adequate anticoagulation treatment when appropriate according to the CHA2DS2-VASc score and current guidelines.

Conclusion

The INDICO AF trial will quantify the incidence of SCAF in patients with an ICD and CAD. The study will underscore the clinical value of SCAF detection in single chamber ICD patients using remote patient monitoring and may improve patient care. This trial is registered at trialregister.nl with trial NTR6910.
  相似文献   

13.

Background

2D strain imaging of the left atrium (LA) is a new echocardiographic method which allows us to determine contractile, conduit and reservoir functions separately. This method is particularly useful when changes are subtle and not easily determined by traditional parameters, as it is in arterial hypertension and atrial fibrillation (AF). The aims of our study were: to determine LA contractile, conduit and reservoir function by 2D strain imaging in patients with mild arterial hypertension and paroxysmal AF; to assess LA contractile, conduit and reservoir functions’ relation with LV diastolic dysfunction (DD) parameters.

Methods

LA contractile, conduit and reservoir functions together with echocardiographic signs of LV DD were assessed in 63 patients with arterial hypertension and paroxysmal AF. Patients were grouped according to number of signs showing LV DD (annular e’ velocity: septal e’?<?7 cm/s, lateral e’?<?10 cm/s, average E/e’ ratio?>?14, LA volume index >?34 ml/m2, peak tricuspid regurgitation velocity?>?2.8 m/s) present. Number of patients with 0 signs – 17, 1 sign – 26, 2 signs – 19. Contractile, conduit and reservoir functions were compared between the groups.

Results

Mean contractile, conduit and reservoir strains in all the patients were???14.14 (± 5.83) %, 15.98 (± 4.85) % and 31.03 (± 7.64) % respectively. Contractile strain did not differ between the groups. Conduit strain was higher in patients with 0 signs compared with other groups (p =?0.016 vs 1 sign of LV DD and p =?0.001 vs 2 signs of LV DD). Reservoir strain was higher in patients with 0 signs compared with other groups (p =?0.014 vs 1 sign of LV DD and p <?0.001 vs 2 signs of LV DD).

Conclusions

The patients with paroxysmal AF and primary arterial hypertension have decreased reservoir, conduit and pump LA functions even in the absence of echocardiographic signs of LV DD. With increasing number of parameters showing LV DD, LA conduit and reservoir functions decrease while contractile does not change. LA conduit and reservoir functions decrease earlier than the diagnosis of LV DD can be established according to the guidelines in patients with primary arterial hypertension and AF.
  相似文献   

14.

Background

The Amigo® Remote Catheter System is a relatively new robotic system for catheter navigation. This study compared feasibility and safety using Amigo (RCM) versus manual catheter manipulation (MCM) to treat paroxysmal atrial fibrillation (PAF). Contact force (CF) and force-time integral (FTI) values obtained during pulmonary vein isolation (PVI) ablation were compared.

Methods

Forty patients were randomly selected for either RCM (20) or MCM (20). All were studied with the Thermocool® SmartTouch® force-sensing catheter (STc). Contact Force (CF), Force Time Integral (FTI) and procedure-related data, were measured/stored in the CARTO®3.

Results

All cases achieved complete PVI without major complications. Mean CF was significantly higher in the RCM group (13.3 ± 7.7 g in RCM vs. 12.04 ± 7.42 g in MCM p < 0.001), as was overall mean FTI (425.6 gs ± 199.6 gs with RCM and 407.5 gs ± 288.0 gs in MCM (p = 0.007) and was more likely to fall into the optimal FTI range (400-1000) using RCM (66.1% versus 49.1%, p < 0.001). FTI was significantly more likely to fall within the optimal range in each PV, as was CF within its optimal range in the right PVs, but trended higher in the left PVs. Freedom from atrial tachyarrhythmia was 90.0% for the RCM and 70.0% for the MCM group (p = 0,12) at 540 days follow-up.

Conclusions

This pilot study suggests that use of the Amigo RCM system, with STc catheter, seems to be safe and effective for PVI ablation in paroxysmal AF patients. A not statistically significant favorable trend was observed for RCM in term of AF-free survival.  相似文献   

15.

Aims

Atrial fibrillation (AF) is the most common sustained arrhythmia encountered in clinical practice. Patients presenting with AF are often admitted to hospital for rhythm or rate control, symptom management, and/or anticoagulation. We investigated temporal trends in AF hospitalizations in United States from 1996 to 2010.

Methods

Data were obtained from the National Hospital Discharge Survey (NHDS), a national probability sample survey of discharges conducted annually by National Center for Health Statistics. Because of the survey design, sampling weights were applied to the raw NHDS data to produce national estimates. Hospitalizations with a primary diagnosis of AF were identified using International Classification of Diseases, 9th Revision, Clinical Modification (ICD-9-CM) code of 427.31. Weighted least squares regression was used to test for linear trends in the number of AF admissions, length of stay, and inpatient mortality. We further stratified AF admissions based on patients' age, gender, and race.

Results

Admissions for a primary diagnosis of AF increased from approximately 286,000 in 1996 to about 410,000 in 2010 with a significant linear trend (β = 9470 additional admissions per year, p < 0.001). The trend of increased AF admissions was uniform across patient sub-groups. Overall, mean length of stay for AF admissions was 3.75 days, and this remained relatively stable over time (β = 0.002 days, p = 0.884). Inpatient mortality was 0.96% and also remained stable over time (β = 0.031%, p = 0.181).

Conclusion

Our data demonstrate an increase in the number of AF admissions but constant length of stay and mortality over time.  相似文献   

16.

Background

Percutaneous left atrial appendage (LAA) closure can be an alternative to coumadin treatment in patients with atrial fibrillation (AF) at high risk for thromboembolic events and/or bleeding complications. We report the initial experience with this new technique.

Methods

Patients were eligible if they had AF with a high stroke risk (CHADS2 score >1), and/or contraindication for coumadin therapy. The procedure was performed under general anaesthesia, using biplane fluoroscopy and (3D) transoesophageal echocardiography (TEE) guidance. Patients were discharged on coumadin until a TEE was repeated at 45 days after closure to evaluate LAA occlusion. If LAA occlusion was achieved, oral anticoagulation was discontinued and aspirin started.

Results

Percutaneous LAA closure was performed in 10 patients (50% male, age 61.6 ± 9.6 years). The median CHADS2 score was 3 (range 2–4), median CHA2DS2-VASc score 3.5 (range 2–6) and HAS-BLED score 1.5 (range 1–4). Nine patients had a history of stroke and 2 patients had a history of major bleeding while on coumadin. Concomitant pulmonary vein isolation was performed in 9 patients. The device was successfully placed in all patients within a median of 56 min (38–137 min). Asymptomatic catheter thrombus occurred in one patient. At 45-day follow-up, no thromboembolic events occurred, TEE showed minimal residual flow in the LAA in three patients. In one patient the LAA device was dislocated, requiring successful percutaneous retrieval.

Conclusion

Device closure of the LAA may provide an alternative strategy to chronic coumadin therapy in patients with AF and high risk of stroke and/or bleeding complications using coumadin.  相似文献   

17.

Background

Cavo-tricuspid isthmus (CTI) block is currently assessed by coronary sinus (CS) pacing or low lateral and septal atrial pacing. Occasionally, CS catheterization through the femoral route can be difficult to perform or right atrial pacing can be problematic because of catheter instability or saturation of the atrial electrograms recorded near the catheter.

Objectives

Our aim was to evaluate the feasibility of assessing cavo-tricuspid isthmus block by means of right ventricular (RV) pacing in patients with ventriculo-atrial conduction, comparing it with CS pacing.

Methods

Circumannular activation was analyzed during CS and RV pacing in consecutive patients in sinus rhythm undergoing CTI ablation for typical atrial flutter. Patients without ventriculo-atrial conduction were excluded from the study. The linear lesion was created during RV pacing and split atrial signals on the ablation line were analyzed. CTI block was confirmed by analyzing local electrograms on the line of block and circumannular activation during CS and RV pacing.

Results

Out of 31 patients, 20 displayed ventriculo-atrial conduction (64%) and were included in the study. Before ablation, during RV stimulation, the collision front of circumannular activation shifted counterclockwise in contrast with the pattern observed during CS pacing. After ablation, circumannular activation was similar during CS and RV pacing, showing fully descending lateral right atrium activation, even if double potentials registered on the ablation line were less widely split during RV pacing than CS pacing (111±26 ms vs 128±30 , p=0.0001).

Conclusions

In patients with ventriculo-atrial conduction, tricuspid annulus activation during CS and RV pacing is similar, before and after CTI ablation. The occurrence of split atrial electrograms separated by an isoelectric interval registered on the line of block can be detected during CS or RV pacing. In patients with difficult CS catheterization via the femoral vein, before trying the subclavian or internal jugular route, if retrograde ventriculo-atrial conduction is present, RV pacing can be an easy trick to assess isthmus block.  相似文献   

18.

Background

Of the antiarrhythmic agents currently marketed in Canada, 5 are commonly used to treat atrial fibrillation (AF). The impact of contraindications, warnings and precautions for the use of these drugs in patients with AF is not known. We evaluated the proportion of patients with AF for whom contraindications, warnings and/or precautions might limit the use of these commonly prescribed drugs and the proportion of patients actually receiving antiarrhythmic drugs despite the presence of contraindications and/or warnings.

Methods

A total of 723 patients with electrocardiographically confirmed, new-onset paroxysmal AF who were enrolled in the Canadian Registry of Atrial Fibrillation were used in this analysis. The 1996 Compendium of Pharmaceuticals and Specialties was used to obtain contraindications, warnings and precautions for use of 5 antiarrhythmic drugs: flecainide, quinidine, sotalol, amiodarone and propafenone. Proportions of patients with contraindications, warnings and/or precautions for use of any of these drugs owing to comorbid conditions or concomitant drug therapy were calculated, regardless of whether the drugs had been prescribed. We then calculated the proportion of patients taking each antiarrhythmic drug at 3 months despite contraindications and/or warnings.

Results

At baseline, when conditions for contraindications and warnings were combined, 414 (57%), 235 (33%), 327 (45%), 285 (39%) and 272 (38%) patients had restrictions for the use of flecainide, quinidine, sotalol, amiodarone and propafenone respectively. Among 465 patients actually taking these medications at 3-month follow-up, 33.3% (2/6), 83.3% (40/48), 36.4% (92/253), 64.1% (25/39) and 34.5% (41/119) respectively had contraindications and/or warnings against their use. The burden of comorbid disease among patients with AF was noteworthy: 404 (56%) had structural heart disease, which included 227 (31%) with ischemic heart disease, 158 (22%) with left ventricular systolic dysfunction and 106 (15%) with heart failure.

Interpretation

The high burden of comorbid disease and concomitant drug use in a large proportion of patients with AF limits the suitability of existing antiarrhythmic drugs. Over one-third of patients with new-onset AF received antiarrhythmic drugs despite the presence of contraindications or warnings. Although such restrictions may not preclude the use of these drugs, the results demonstrate the need for new antiarrhythmic drugs with fewer limitations.Atrial fibrillation (AF) is the most frequently encountered sustained arrhythmia in clinical practice and accounts for more physician visits and hospital days than any other cardiac arrhythmia.1 Although it is usually not life-threatening, AF is associated with substantial morbidity and increased mortality, largely because of the increased risk of stroke and thromboembolic events.2,3,4Maintenance of sinus rhythm by means of cardioversion and use of antiarrhythmic drugs is often the initial therapy for AF,5 although the results of recent randomized controlled trials have cast doubt on whether rhythm control should be routinely applied in patients with atrial fibrillation or flutter.6,7 Several factors are offered as justification for the use of antiarrhythmic drug therapy: symptoms can substantially impair quality of life,8,9 lack of active atrial transport and irregular, frequently rapid ventricular rates may result in reduced exercise capacity, dyspnea and cardiomyopathy; and the risk of stroke and thromboembolism is increased, owing to incomplete atrial emptying and stasis in the noncontracting atria.10Of the antiarrhythmic agents approved for use in Canada, 5 are prescribed relatively commonly. All 5 are indicated for ventricular arrhythmias, and 2 (flecainide and quinidine) are approved for supraventricular arrhythmias (SVA) in patients without structural heart disease. Sotalol, propafenone and amiodarone, although not officially approved for SVA in Canada, are the antiarrhythmic agents most commonly prescribed for AF.7,11 Each drug has labelling that identifies contraindications, warnings and precautions for use in the setting of cardiac and noncardiac conditions. The frequency of these restrictions and the extent to which these drugs are used despite restrictions among patients with AF are not known. To address this problem we sought to describe the frequency and impact of contraindications and warnings among patients in whom the use of antiarrhythmic drugs would likely be contemplated.  相似文献   

19.

Background and Purpose

Diagnosis of paroxysmal atrial fibrillation (AF) can be challenging, but it is highly relevant in patients presenting with sinus rhythm and acute cerebral ischemia. We aimed to evaluate prospectively whether natriuretic peptide levels and kinetics identify patients with paroxysmal AF.

Methods

Patients with acute cerebral ischemia were included into the prospective observational Find-AF study. N-terminal pro brain-type natriuretic peptide (NT-proBNP), brain-type natriuretic peptide (BNP) and N-terminal pro atrial-type natriuretic peptide (NT-proANP) plasma levels were measured on admission, after 6 and 24 hours. Patients free from AF at presentation received 7 day Holter monitoring. We prospectively hypothesized that patients presenting in sinus rhythm with NT-proBNP>median were more likely to have paroxysmal AF than patients with NT-proBNPResults281 patients were included, of whom 237 (84.3%) presented in sinus rhythm. 220 patients naïve to AF with an evaluable prolonged Holter ECG were analysed. In patients with NT-proBNP>median (239 pg/ml), 17.9% had paroxysmal AF in contrast to 7.4% with NT-proBNP<239 pg/ml (p = 0.025). The ratio of early (0 h) to late (24 h) plasma levels of NT-proBNP showed no difference between both groups. For the detection of paroxysmal atrial fibrillation, BNP, NT-proBNP and NT-proANP at admission had an area under the curve in ROC analysis of 0.747 (0.663–0.831), 0.638 (0.531–0.744) and 0.663 (0.566–0.761), respectively. In multivariate analysis, BNP was the only biomarker to be independently predictive for paroxysmal atrial fibrillation.

Conclusions

BNP is independently predictive of paroxysmal AF detected by prolonged ECG monitoring in patients with cerebral ischemia and may be used to effectively select patients for prolonged Holter monitoring.  相似文献   

20.

Background

Atrial tissue fibrosis can cause electrical or structural remodeling in patients with atrial fibrillation. Transforming growth factor beta 1(TGF-β1) signaling acts as a central role in fibroblast activation. In this report, we aimed to investigate the relationship between serum level of TGF-β1 and mean left atrial voltage in patients with chronic atrial fibrillation (CAF).

Methods

A total of 16 consecutive adult patients with CAF who underwent catheter ablation were enrolled. Blood samples for measurement of TGF-β1 were collected from periphery veins and coronary sinus before pulmonary vein isolation. The measurement was performed with a commercially available ELISA kit. Cardiac indices were measured using echocardiography. The left atrial electroanatomic mapping was performed after pulmonary vein isolation.

Results

Serum level of TGF-β1 in peripheral blood was higher than that in coronary sinus (p < 0.001). TGF-β1 serum level in coronary sinus negatively correlated with mean left atrial voltage (r = -0.650, p = 0.012), While periphery TGF-β1 level tended to be negatively correlated with mean left atrial voltage(r = -0.492, p = 0.053). Patients who treated with angiotensin II receptor antagonists had lower coronary sinus TGF-β1 serum level than those who did not treated with angiotensin II receptor antagonists (p = 0.046).

Conclusion

Level of TGF-β1 in peripheral serum is higher than that in coronary sinus, and serum level of TGF-β1 in coronary sinus is negatively associated with mean left atrial voltage in patients with CAF, angiotensin II receptor antagonists could affect TGF-β1 serum level.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号