首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
BackgroundUltrasound-guided axillary venous puncture (UGAVP) for cardiac devices implantation has been developed because of its rapidity, safety and potential long-term lead protection. Early work excluded defibrillators (ICD), cardiac resynchronization therapy (CRT) and upgrade procedures. Compared to the cephalic approach, in previous studies, there was a greater use of pressure dressings with this technique, suggesting a higher risk of bleeding.AimsTo assess UGAVP in patients under antithrombotic therapy (ATT) undergoing cardiac devices implantation including CRT/ICD.MethodsProspectively, consecutive patients eligible for a pacemaker or ICD implantation were included. All procedures were performed by a single operator, experienced with UGAVP for femoral access, and fluoroscopy-guided axillary vein access. Guidewires insertion time (from lidocaïne administration), and complications were systematically studied.ResultsFrom 457 cardiac device implantations, 200 patients (77.8 ± 10 y, male 58%) 360 leads were implanted by UGAVP including 36 ICD, 54 CRT and 14 upgrade procedures. A majority (90%) was under ATT: Vitamin K Antagonist or Heparin (n = 58, 29%), direct oral anticoagulant (n = 46, 23%), dual antithrombotic therapy (n = 18, 9%) and single antiplatelet drug (n = 82, 41%). UGAVP was successful in 95.78%. Mean insertion time for 1.8 guidewires per patient was 4.68 ± 3.6 min. No complication (no hematoma) was observed during the follow-up (mean of 45 ± 10 months). Guidewires insertion time reached its plateau after 15 patients.ConclusionUGAVP is fast, feasible and safe for patients under ATT undergoing device implantation including CRT/ICD and upgrade procedures, with a short learning curve.  相似文献   

2.
With the increasing number of cardiovascular implantable electronic device upgrade and vein obstruction caused by previous leads, it is important to have alternative techniques to upgrade the device with the maintenance of functioning leads.We report an 83-year old male with 13-year old one-lead dual-chamber pacemaker, ischemic cardiac disease and pre-dialytic chronic kidney disease submitted to an upgrade to cardiac resynchronization therapy. A sub-occlusion in the transition of left brachiocephalic vein and the superior vena cava was documented. Re-permeabilization was only achieved with a TightRail? rotating dilator sheath over a guidewire with successful left ventricle lead implant.  相似文献   

3.
There are several very obvious and simple solutions for eliminating the "Pitfalls" and for minimizing the risk of occurrence of any perioperative complications associated with placement of chronic indwelling central venous access devices in cancer patients. The first is the utilization of a venous cutdown approach, such as the cephalic vein or the external jugular vein, which essentially eliminates potentially life-threatening perioperative complications, such as pneumothorax and injury to the great vessels (with or without associated hemothorax). The second is the selective and appropriate utilization of intraoperative venography for defining the central venous anatomy and for providing a venous roadmap in those particularly challenging cases in which difficulties are encountered during chronic indwelling central venous access device placement.  相似文献   

4.
Background Two novel approaches to implanting a central venous catheter port in non‐human primates (NHPs) using peripheral insertion are presented and compared. Methods Sixty vascular access port (VAP) implants were attempted in 52 NHPs by saphenous vein puncture (n = 20) or saphenous vein cutdown (n = 40). Results Fifty eight procedures were successful. Eighteen of 20 VAPs were successfully placed using saphenous vein puncture, and 40 of 40 using saphenous vein cutdown. There were no significant differences between procedures. Mean implantation times were similar between groups. At explant or study endpoint, all 58 VAPs were patent. Conclusions Vascular access port implantation by saphenous vein puncture or saphenous vein cutdown is safe and effective in NHPs. It is less invasive than conventional procedures, has fewer complications, provides outstanding patency, and reduces surgery time. Furthermore, it allows for cooperative in‐homecage VAP use, minimizing handling stress. We recommend these refined methods for long‐term vascular access in NHPs.  相似文献   

5.
目的:观察下肢静脉性溃疡患者穿静脉功能不全情况,探讨超声定位下肢穿静脉结扎对下肢静脉性溃疡术后疗效的影响。方法:40例大隐静脉曲张患者随机分成两组:A组采用大隐静脉高位结扎、静脉腔内微波射频闭合术及超声定位穿静脉结扎治疗,B组采用大隐静脉高位结扎和静脉腔内微波射频闭合术治疗。观察两组患者治疗后静脉性溃疡的愈合时间、复发率及瓣膜功能不全穿静脉数量部位,并比较两组患者临床预后评分。结果:术前两组瓣膜功能不全穿静脉数量分别是47条和44条,两组比较差异无统计学意义(P=0.5520)。术后两组愈合时间分别是(7.5±4.389)周和(11.6±6.489)周,两组比较差异具有统计学意义(P=0.048)。两组临床预后评分分别为(2.3±0.6)分和(1.1±1.5)分,两组比较差异具有统计学意义(P=0.042)。结论:多普勒超声可有效检测定位瓣膜功能不全的下肢穿静脉,在超声定位下行大隐静脉高位结扎、静脉腔内微波射频闭合术联合穿静脉结扎治疗下肢静脉性溃疡的疗效优于穿静脉不结扎。  相似文献   

6.
The lack of adequate recipient vessels often complicates microvascular breast reconstruction in patients who have previously undergone mastectomy and irradiation. In addition, significant size mismatch, particularly in the outflow veins, is an important contributor to vessel thrombosis and flap failure. The purpose of this study was to review the authors' experience with alternative venous outflow vessels for microvascular breast reconstruction. In a retrospective analysis of 1278 microvascular breast reconstructions performed over a 10-year period, the authors identified all patients in whom the external jugular or cephalic veins were used as the outflow vessels. Patient demographics, flap choice, the reasons for the use of alternative venous drainage vessels, and the incidence of microsurgical complications were analyzed. The external jugular was used in 23 flaps performed in procedures with 22 patients. The superior gluteal and transverse rectus abdominis musculocutaneous (TRAM) flaps were used in the majority of the cases in which the external jugular vein was used (72 percent gluteal, 20 percent TRAM flap). The need for alternative venous outflow vessels was usually due to a significant vessel size mismatch between the superior gluteal and internal mammary veins (74 percent). For three of the external jugular vein flaps (13 percent), the vein was used for salvage after the primary draining vein thrombosed, and two of three flaps in these cases were eventually salvaged. In three patients, the external jugular vein thrombosed, resulting in two flap losses, while the third was salvaged using the cephalic vein. A total of two flaps were lost in the external jugular vein group. The cephalic vein was used in 11 flaps (TRAM, 64.3 percent; superior gluteal, 35.7 percent) performed in 11 patients. In five patients (54.5 percent), the cephalic vein was used to salvage a flap after the primary draining vein thrombosed; the procedure was successful in four cases. In three patients, the cephalic vein thrombosed, resulting in two flap losses. One patient suffered a thrombosis after the cephalic vein was used to salvage a flap in which the external jugular vein was initially used, leading to flap loss, while a second patient experienced cephalic vein thrombosis on postoperative day 7 while carrying a heavy package. There was only one minor complication attributable to the harvest of the external jugular or cephalic vein (small neck hematoma that was aspirated), and the resultant scars were excellent. The external jugular and cephalic veins are important ancillary veins available for microvascular breast reconstruction. The dissection of these vessels is straightforward, and their use is well tolerated and highly successful.  相似文献   

7.
Epicardial pacing lead fixation is employed in patients with cavopulmonary anastamosis (Glenn shunts) when they need permanent pacing. Epicardial pacing in these patients may malfunction due to high pacing thresholds or diaphragmatic pacing. A novel technique of transatrial insertion of two endocardial screw-in pacing leads through right anterolateral minithoracotomy could achieve synchronous atrioventricular pacing in a patient with Ebsteins anomaly with symptomatic sinoatrial and atrioventricular nodal disease.  相似文献   

8.
Pneumothorax is a mild complication during pacemaker lead implantation using the subclavian puncture technique. We report on five-year experience in 433 pacemaker lead implantation procedures in 379 patients. The cephalic vein route was solely used in twelve patients. Three procedures were performed over time in four patients and one patient needed four repetitive punctures for pacemaker lead implantation and replacement. Thus 421 punctures were carried out in 367 patients. Eleven case of pneumothorax were observed: in eight patients (1.9%) a partial pneumothorax occurred and in three patients (0.7%) the pneumothorax was nearly complete. In the latter patients a chest tube was inserted and hospital admission was prolonged for 3, 6 and 6 days, respectively. Old age with a corresponding abnormality in the form of chest deformation were predominantly found in the patients with this type of complication.  相似文献   

9.
BackgroundWe demonstrate a case series of 8 pediatric patients, all under 30 kg, who had leadless pacemaker implants via the internal jugular vein.MethodsA retrospective review of pediatric leadless pacing placement via the internal jugular vein at the University of Minnesota Masonic Children's Hospital and UC Davis Medical Center from 2018 through 2021 was performed. Rationales for pacing, demographics of patients, pacing thresholds, and longevity of devices were recorded.ResultsEight internal jugular pacemaker insertions were performed successfully in patients weighing between 10.9 kg and 29 kg. Five patients had Micra implantation via the right internal jugular vein, whereas 3 patients had insertion via the left internal jugular vein. No surgical cut-downs were performed. No venous complications occurred. Up to 3 years of follow-up were noted.ConclusionLeadless pacemaker implantation, via left or right internal jugular veins, is feasible without surgical cutdown in patients <30 kg  相似文献   

10.
We report two cases of patients of cardiac resynchronization therapy (CRT) whose ECGs, during follow up, showed different paced QRS morphology as compared to those of immediate post-device implantation. Parameters of leads, including sensitivity and capture thresholds, were unchanged. There was no lead dislodgement confirmed on fluoroscopy. The ECGs obtained in device off mode showed different intrinsic QRS morphology as compared to those of pre-implant morphology. These changes were attributable to electrolyte imbalance in one patient and progressive intraventricular conduction defect in the other. These cases demonstrate that intrinsic myocardial conduction pattern influences paced QRS morphology. Irreversible change in paced QRS morphology may indicate poor prognosis.  相似文献   

11.
This case highlights the importance of proper identification of congenital anomalies of the coronary sinus for the successful placement of left ventricular lead during cardiac resynchronization therapy device implantation. We discuss an alternate route for left ventricular lead placement via the vein of Marshall when the coronary sinus ostium in the right atrium was atretic and was facing difficulty initially in detecting the anomaly.  相似文献   

12.

Background

Airway management of the obese patient presenting for surgery is more likely to be a challenging problem. Supraglottic airway device has been adopted as a bridge to connect ventilation and tracheal intubation in obese patients who would be suffered with difficult intubation. The optimum sevoflurane concentration for supraglottic airway device insertion allowing spontaneous breathing in 50% of obese patients (ED50) is not known. The purpose of this study was to determine the ED50 of sevoflurane for supraglottic airway device Blockbuster? insertion with spontaneous breathing in obese patients requiring general anesthesia.

Methods

Thirty elective obese patients (body mass index 30-50 kg/m2) undergoing bariatric surgery were recruited in this study. The predetermined target sevoflurane concentration (initiating at 2.5% with 0.5% as a step size) was sustained for >5 min using a modified Dixon’s up-and-down method, and then the supraglottic airway device Blockbuster? was inserted. The patient’s response to supraglottic airway device insertion was classified as either ‘movement’ or ‘no-movement’. The ED50 of sevoflurane were determined by calculating the midpoint concentration of crossover point from ‘movement’ or ‘no-movement’ response.

Results

The ED50 of sevoflurane for supraglottic airway device Blockbuster? insertion in obese patients calculated using up-and-down method were 2.50?±?0.60%. The ED50 and ED95 (95% confidence interval) obtained by probit regression analysis were 2.35 (1.28–3.42) % and 4.03 (3.16–17.83) % for supraglottic airway device Blockbuster? insertion, respectively.

Conclusion

We conclude that the optimum end-tidal sevoflurane concentration required for the supraglottic airway device Blockbuster? insertion allowing spontaneous breathing in 50% of obese patients (ED50) is 2.5?±?0.6%.

Trial registration

Chinese Clinical Trial Registry, ChiCTR-IPR-16009071, Registered on 24 August 2016.
  相似文献   

13.
Histone deacetylase 2 (HDAC2) is an emerging target of Alzheimer’s disease. Four featured pharmacophore model (ADRR) with one H-bond acceptor (A), one H-bond donor (D), and two aromatic rings (R) was generated using experimentally reported compounds, ((E-5[3-benzenesulfonamido) phenyl]-N-hydroxypent-2-en-4-ynamide)) and (N’-hydroxy-N-phenyloctanediamide) with IC50 values of 0.16?±?0.11?nM and 62?±?0.15?nM, respectively. Quantum Polarized Ligand Docking and Binding Free Energy calculation was performed for the top three identified leads RH01652, JFD02573, and HTS00800 from HitFinder database. RH01652 (methyl 2-[({5-[(benzoylamino) methyl]-2-thienyl} sulfonyl) amino]-3-(1H-indol-3-yl) propanoate) with docking score (?12.62?kcal/mol) and binding free energy (?75.27?kcal/mol), shows good binding affinity. RH01652 interacts with Gly154, His183, Glu208, and Phe210 with four H-bonds and stabilized by π–π interactions with His146, Tyr209, and Phe210. DFT studies at B3LYP level with 6-31G* basis set for the lead RH01652 reveals low band gap/ΔE (EHOMOELUMO) of ?0.16?eV, which illustrates good reactivity of the lead. MD simulation studies (40?ns) was performed to confirm the stability of lead binding. Comparative molecular docking studies of the lead RH01652 with class I HDACs (HDAC1, HDAC2, HDAC3, and HDAC8) shows higher binding affinity towards HDAC2. Thus, lead RH01652 could serve as template to design novel and potent inhibitor of HDAC2.  相似文献   

14.
目的经颈静脉途径应用心室起搏的方法制备心脏记忆犬模型。方法 8只普通级成年健康Beagle犬经腹腔麻醉后,Seldinger’s法穿刺颈外静脉成功后送入心内膜起搏电极,将电极头端固定于右室心尖部,近端连接于脉冲发生器。起搏频率设置较犬窦性心律时的基础心率快15%,保证起搏器连续起搏。结果连续起搏1周后所有动物均成功制备为心脏记忆模型。建模后犬的心率、呼吸、体重与建模前比较,无明显改变;所有模型组犬起搏前心电图均为窦性心律,起搏1周后出现心脏T波记忆,在下壁导联以及胸前导联均出现T波倒置,停止起搏后,心脏T波记忆逐渐消失;模型组犬与正常组犬心肌病理相比,无明显改变。结论经颈静脉途径应用心室起搏法建立心脏记忆犬模型的方法,具有手术简单,创伤小,诱发方式与临床相似等优点,为深入展开心脏记忆的机制研究奠定基础。  相似文献   

15.
IntroductionCurrent guidelines advocate reviewing peri-procedural anticoagulation on individual case basis for transvenous lead extraction (TLE). We investigated the safety of TLE on uninterrupted warfarin with therapeutic INR.MethodsRetrospective registry of consecutive patients undergoing TLE on uninterrupted warfarin (Warfarin Group) across two centres. Age and sex matched controls not on anticoagulation (No-Warfarin Group) and undergoing TLE over the same time-period were included. Both groups were compared over one-year.Results121 TLEs over 18-months. 22 patients on uninterrupted anticoagulation were compared to 22 controls. Groups were well matched for baseline demographics other than INR. Warfarin group had mean INR of 2.2 ± 0.6 (range 2–3.5). Primary end point was procedural safety and efficacy. Amongst cases, 43/45 (96%) leads were removed in their entirety compared to 37/40 (93%) in controls (p = 0.66). In the cases, these included 44% defibrillator, 47% pace-sense and 9% CS leads of average duration 7yrs. There was no reported tamponade, haemothorax or procedural mortality in either group. One patient amongst cases required inotropic support while two patients amongst controls had device-site haematomas. No significant difference reported in Hb drop post-procedure or overall complication rate between the groups (p = 0.11,0.32). Cox regression showed a significant association between procedural success and device infection, number of leads extracted, serum creatinine (p = 0.03, 0.04, 0.02). Over a 1-year follow-up, there was lead displacement in one case and one control had infection of the re-implanted device.ConclusionTLE can be carried out safely in anticoagulated patients with therapeutic INRs. Larger multicentre studies are required to confirm these findings.  相似文献   

16.
A study of the arrangement of the superficial veins of the cubital fossa was made on 300 students and staff of the Military Medical College and the AlMustansiriya College of Medicine. Six types of variations of arrangement of the veins were found, two of which have not been mentioned before. The commonest type was that the median vein of the forearm divides in the cubital fossa into 2 veins, one of which joins the basilic vein, and the other the cephalic vein, although in a few cases this joining (or arrangement), occurred above the cubital fossa. The arrangements which have not been mentioned before were that the communication between basilic and cephalic veins was through a horizontal venous connection between 1 of the tributaries of these 2 veins and the basilic vein, and that the median vein of the forearm divides into median cephalic and median basilic, and a vein from the front of the forearm drains into the median basilic vein.  相似文献   

17.
Many patients receiving cardiac resynchronization therapy (CRT) suffer from permanent atrial fibrillation (AF). Knowledge of the atrial rhythm is important to direct pharmacological or interventional treatment as well as maintaining AV-synchronous biventricular pacing if sinus rhythm can be restored. A single pass single-coil defibrillator lead with a floating atrial bipole has been shown to obtain reliable information about the atrial rhythm but has never been employed in a CRT-system. The purpose of this study was to assess the feasibility of implanting a single coil right ventricular ICD lead with a floating atrial bipole and the signal quality of atrial electrograms (AEGM) in CRT-defibrillator recipients with permanent AF.

Methods and results

Seventeen patients (16 males, mean age 73?±?6 years, mean EF 25?±?5%) with permanent AF and an indication for CRT-defibrillator placement were implanted with a designated CRT-D system comprising a single pass defibrillator lead with a atrial floating bipole. They were followed-up for 103?±?22 days using remote monitoring for AEGM transmission. All patients had at last one AEGM suitable for atrial rhythm diagnosis and of 100 AEGM 99% were suitable for visual atrial rhythm assessment. Four patients were discharged in sinus rhythm and one reverted to AF during follow-up.

Conclusion

Atrial electrograms retrieved from a single-pass defibrillator lead with a floating atrial bipole can be reliably used for atrial rhythm diagnosis in CRT recipients with permanent AF. Hence, a single pass ventricular defibrillator lead with a floating bipole can be considered in this population.  相似文献   

18.
杨玲娟  邹金梅  倪雪梅  曹梅  熊玮 《生物磁学》2013,(34):6676-6678
目的:比较经贵要静脉、肘正中静脉、头静脉三种不同途径进行PICC置管的成功率和置管术后机械性静脉炎的发生率,以寻找最佳置管途径。方法:对2010年-2012年入住我科的153例肿瘤患者PICC置管的成功率和置管术后机械性静脉炎的发生率,进行回顾性研究。结果:三种途径PICC置管成功率比较:贵要静脉〉肘正中静脉〉头静脉,差异有统计学意义(P〈0.05)。三种途径PICC置管术后机械性静脉炎的发生率比较:贵要静脉〈肘正中静脉〈头静脉,差异有统计学意义(P〈0.05)。结论:PICC置管的途径应首选贵要静脉,次选肘正中静脉,最后选头静脉。  相似文献   

19.

Background

In vitro isolated heart preparations are valuable tools for the study of cardiac anatomy and physiology, as well as for preclinical device testing. Such preparations afford investigators a high level of hemodynamic control, independent of host or systemic interactions. Here we hypothesize that recovered human and swine heart-lung blocs can be reanimated using a clear perfusate and elicit viable cardiodynamic and pulmonic function. Further, this approach will facilitate multimodal imaging, which is particularly valuable for the study of both functional anatomy and device-tissue interactions. Five human and 18 swine heart-lung preparations were procured using techniques analogous to those for cardiac transplant. Specimens were then rewarmed and reperfused using modifications of a closed circuit, isolated, beating and ventilated heart-lung preparation. Positive pressure mechanical ventilation was also employed, and epicardial defibrillation was applied to elicit native cardiac sinus rhythm. Videoscopy, fluoroscopy, ultrasound, and infrared imaging were performed for anatomical and experimental study.

Results

Systolic and diastolic left ventricular pressures observed for human and swine specimens were 68/2?±?11/7 and 74/3?±?17/5 mmHg, respectively, with associated native heart rates of 80?±?7 and 96?±?16 beats per minute. High-resolution imaging within functioning human pulmonary vasculature was obtained among other anatomies of interest. Note that one human specimen elicited poor cardiac performance post defibrillation.

Conclusions

We report the first dynamic videoscopic images of the pulmonary vasculature during viable cardiopulmonary function in isolated reanimated heart-lung blocs. This experimental approach provides unique in vitro opportunities for the study of novel medical therapeutics applied to large mammalian, including human, heart-lung specimens.
  相似文献   

20.

Background

The number of cardiac rhythm device implantations has been growing fast due to expanding indications and ageing of the population. Complications of implantation were rare in the trials. However, these involved small numbers and selected patients. Prospective real-life data are necessary to assess cardiac device implantation procedure-related risks.

Objective

To determine the incidence and predictors of lead-related re-intervention in a Dutch high-volume teaching hospital.

Methods

Data from all patients who underwent cardiac rhythm device implantation between January 2010 and December 2011 were collected in a prospective registry. At least 1 year of follow-up regarding re-intervention was available for all patients. Lead-related reasons for re-intervention were categorised into lead dislodgement, malfunctioning or perforation.

Results

One thousand nine hundred twenty-nine devices including 3909 leads were implanted. In 595 patients (30.8 %) a CRT-D/P was implanted. Lead-related re-intervention was necessary in 86 (4.4 %) patients; it was more common in younger and male patients, and due to either lead dislodgement (66 %), malfunctioning (20 %) or perforation (18 %). Coronary sinus lead dislodgement or malfunctioning was 1.4 %. Right atrial dislodgement (1.9 %, p < 0.001) or ICD lead dislodgement (1.8 %, p = 0.002) was more common than right ventricular dislodgement (0.3 %). The incidence of lead malfunctioning was higher (0.8 %) in ICD leads. An apical position of the right ventricular lead and lateral wall position of the right atrial lead were related to cardiac perforation.

Conclusions

The incidence of lead-related re-intervention was comparable with the literature. The majority of re-interventions were due to lead dislodgements, particularly with right atrial and ICD leads. Re-intervention due to coronary sinus lead dislodgement was rare.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏