首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Femoral head size provides important information on body size in extinct species. Although it is well‐known that femoral head size is correlated with acetabular size, the precision with which femoral head size can be estimated from acetabular size has not been quantified. The availability of accurate 3D surface models of fossil acetabular remains opens the possibility of obtaining accurate estimates of femoral head size from even fragmentary fossil remains [Hammond et al.,: Am J Phys Anthropol 150 (2013) 565–578]. Here we evaluate the relationship between spheres fit to surface models of the femoral head and acetabulum of a large sample of extant anthropoid primates. Sphere diameters are tightly correlated and scale isometrically. In spite of significant taxonomic and possibly functional differences in the relationship between femoral head size and acetabulum size, percent prediction errors of estimated femoral head size remain low regardless of the taxonomic composition of the reference sample. We provide estimates of femoral head size for a series of fossil hominins and monkeys. Am J Phys Anthropol 155:469–475, 2014. © 2014 Wiley Periodicals, Inc.  相似文献   

2.
In an earlier paper, the authors presented a new method of computation of slide tracks in the relative motion between femoral head and acetabular cup of total hip prostheses. For the first time, computed tracks were verified experimentally and with an alternative method of computation. Besides being an efficient way to illustrate hip kinematics, the shapes of the slide tracks are known to be of fundamental importance regarding the wear behaviour of prostheses. The verified method was now applied to eight contemporary hip simulator designs. The use of correct motion waveforms and an Euler sequence of rotations in each case was again found to be essential. Considerable differences were found between the simulators. For instance, the shapes of the tracks drawn by the resultant contact force included a circle, ellipse, irregular oval, leaf, twig, and straight line. Computation of tracks correctly for the most widely used hip simulator, known as biaxial, was made possible by the insight that the device is actually three-axial. Slide track patterns have now been computed for virtually all contemporary hip simulators, and both for the heads and for the cups. This comparative analysis forms a valuable basis for studies on the relationship between the type of multidirectional motion and wear. These studies can produce useful information for the design of joint simulators, and improve the understanding of wear phenomena in prosthetic joints.  相似文献   

3.
Numerous supporting structures assist in the retention of the femoral head within the acetabulum of the normal hip joint including the capsule, labrum, and ligament of the femoral head (LHF). During total hip arthroplasty (THA), the LHF is often disrupted or degenerative and is surgically removed. In addition, a portion of the remaining supporting structures is transected or resected to facilitate surgical exposure. The present study analyzes the effects of LHF absence and surgical dissection in THA patients. Twenty subjects (5 normal hip joints, 10 nonconstrained THA, and 5 constrained THA) were evaluated using fluoroscopy while performing active hip abduction. All THA subjects were considered clinically successful. Fluoroscopic videos of the normal hips were analyzed using digitization, while those with THA were assessed using a computerized interactive model-fitting technique. The distance between the femoral head and acetabulum was measured to determine if femoral head separation occurred. Error analysis revealed measurements to be accurate within 0.75mm. No separation was observed in normal hips or those subjects implanted with constrained THA, while all 10 (100%) with unconstrained THA demonstrated femoral head separation, averaging 3.3mm (range 1.9-5.2mm). This study has shown that separation of the prosthetic femoral head from the acetabular component can occur. The normal hip joint has surrounding capsuloligamentous structures and a ligament attaching the femoral head to the acetabulum. We hypothesize that these soft tissue supports create a passive, resistant force at the hip, preventing femoral head separation. The absence of these supporting structures after THA may allow increased hip joint forces, which may play a role in premature polyethylene wear or prosthetic loosening.  相似文献   

4.
Hip joints (280) from 140 human fetuses, obtained from abortions and deaths in the perinatal period, were studied. The fetuses ranged from 8.7 to 40 cm in crown-rump length and are believed to be between 12 and 42 weeks in age. The joints were dissected, morphology inspected, and measurements taken of the depth and diameter of the acetabulum, the diameter of the femoral head, length and width of the ligament of the head, the neck-shaft, and torsion angles of the proximal femur. Regression models were fitted to determine which would best predict the growth pattern. Multivariate analysis of variance showed no significant differences between males and females or between the right and left sides. Acetabular depth was shown to be the slowest-growing hip variable, increasing less than fourfold in the period studied. Acetabular indices less than 50 percent indicate a shallow socket at term. Femoral head and acetabular diameter demonstrated a strong relationship (r = 0.860) and in many joints the femoral head diameter exceeded that of the acetabulum. Considerable variability was demonstrated in both femoral angles. The femoral angles showed only low correlation with the other hip variables. These observations indicate that soft tissue structures about the joint must play an important role in neonatal joint stability. The explanation of greater female and left side involvement in congenital hip disease must lie in factors other than growth changes of hip dimensions. Neither angle appears to be a useful indicator of normal joint development.  相似文献   

5.
《Comptes Rendus Palevol》2014,13(8):747-754
In order to maximize sample sizes for the assessment of body size and proportions among Late Pleistocene humans, the femoral head diameter of the Regourdou 1 Neandertal was estimated from its ischial acetabular lunate surface, so as to provide a reliable measure for body mass assessment. This estimate was accomplished by fitting a sphere to the 3D surface of the acetabulum and then estimating femoral head diameter using a regression of acetabular sphere diameter to femoral head diameter based on associated recent human femora and ossa coxarum. The resultant mean and range of values for the Regourdou 1 femoral head dimension place it among the smaller of the European and southwest Asian Neandertals, although its humeral length is above average for that sample. Regourdou 1 therefore joins Kebara 2 in having moderately long arms for body core size, and it thereby emphasizes the variation in Neandertal body proportions.  相似文献   

6.
摘要:髋关节撞击综合征(femoroacetabular impingement,FAI)是以髋关节解剖结构异常而引发的股骨近端和髋臼间发生异常碰 撞,从而导致髋关节盂唇和关节软骨的退行性变化,引起髋关节慢性疼痛的疾病。髋关节活动范围特别是屈曲和内旋受限,最终 发展为髋关节骨关节炎。FAI在我国国内为一个较新的概念,临床能得到诊断的病例不多,但实际病例很多,相当一部分的髋关节 疼痛是由撞击征造成,平常的药物止痛不能解除持续的撞击,最终会发生骨关节炎。由此早期的诊断及手术干预,可以消除疼痛, 防止骨关节炎的发生,进而推迟或消除关节置换手术是有巨大的经济和社会价值。  相似文献   

7.
Today, only hard/soft cup and femoral head combinations are employed for hip joint prostheses. Highly polished ceramic is a material with very good tribological properties for femoral heads, being highly resistant to mechanical wear and tear, and highly resistant to chemical reactions in the biological environment. The advantage of metal heads, in contrast, undoubtedly lies in their resistance to breakage and the ease with which their geometry can be modified with respect, for example, to antirotation angle and neck length. The ideal material for femoral heads is a combination of the two materials. The new multi-layer combination of titanium-niobium oxide/nitride ceramic coating applied to a prehardened titanium head combines the positive material properties in an ideal manner. Femoral heads made of CoCrMo, oxide-hardened titanium, aluminium oxide or multilayer titanium-niobium ceramic were compared by means of friction an wear and tear tests. The TiNb-ceramic-metal heads showed similar abrasion at the surface as the ceramic heads. At the high loads of more than 400 kp, which may also be reached under physiological conditions, the specially coated titanium-ceramic heads proved to be superior in terms of resistance to fracture and tribological properties.  相似文献   

8.
An appropriate method of application of the hip-joint force and stress analysis of the pelvic bone, in particular the acetabulum, is necessary to investigate the changes in load transfer due to implantation and to calculate the reference stimulus for bone remodelling simulations. The purpose of the study is to develop a realistic 3D finite element (FE) model of the hemi-pelvis and to assess stress and strain distribution during a gait cycle. The FE modelling approach of the pelvic bone was based on CT scan data and image segmentation of cortical and cancellous bone boundaries. Application of hip-joint force through an anatomical femoral head having a cartilage layer was found to be more appropriate than a perfectly spherical head, thereby leading to more accurate stress–strain distribution in the acetabulum. Within the acetabulum, equivalent strains varied between 0.1% and 0.7% strain in the cancellous bone. High compressive (15–30 MPa) and low tensile (0–5 MPa) stresses were generated within the acetabulum. The hip-joint force is predominantly transferred from the acetabulum through the lateral cortex to the sacroiliac joint and the pubic symphysis. The study is useful to understand the load transfer within the acetabulum and for further investigations on acetabular prosthesis.  相似文献   

9.
This note describes a mathematical method for the calculation of surface area of the femoral head covered ('contained') by the acetabulum as a time-dependent function. It uses displacement vectors from the center of rotation of the hip joint to the femoral joint surface, and rotates these vectors in small increments to simulate the desired motion. At each interval, the vectors are tested to determine whether they lie within the coverage area of the acetabulum. The result is a containment density plot which displays coverage area as a function of time. The general method is used in a variety of clinically important situations, and an example of its use in the study of abduction bracing is described.  相似文献   

10.
In an earlier paper, the authors presented the first verified method of computation of slide tracks in the relative motion between femoral head and acetabular cup of total hip prostheses. The method was applied for gait and for two hip simulator designs, and in a subsequent paper, for another eight designs. In the present paper, the track drawn by the resultant contact force, the so-called force track, was studied in depth. The variations of sliding distance, sliding velocity and direction of sliding during a cycle, all of which are important with respect to wear, were computed for gait and for 11 hip simulator designs. Moreover, the product of the instantaneous load and increment of sliding distance was numerically integrated over a cycle. This integral makes it possible to compare clinical wear rates with those produced by hip simulators in terms of a wear factor. For the majority of contemporary hip simulators, the integral has so far been unknown. The computations revealed considerable differences, which are likely to explain the substantial differences in wear produced by the simulators. With the most common head diameter, 28 mm, the ranges for sliding distance per cycle, mean sliding velocity, total change of direction of sliding and integral were: 19.7-34.3 mm, 19.7-49.0 mm/s, 360-1513 degrees, and 17.4-43.5 Nm, respectively.  相似文献   

11.
吴奇  韩一生  张振宇  陈伯亮  郭建斌 《生物磁学》2014,(8):1587-1590,1600
髋关节撞击综合征(femoroacetabularimpingement,FAI)是以髋关节解剖结构异常而引发的股骨近端和髋臼间发生异常碰撞,从而导致髋关节孟唇和关节软骨的退行性变化,引起髋关节慢性疼痛的疾病。髋关节活动范围特别是屈曲和内旋受限,最终发展为髋关节骨关节炎。FAI在我国国内为一个较新的概念,临床能得到诊断的病例不多,但实际病例很多,相当一部分的髋关节疼痛是由撞击征造成,平常的药物止痛不能解除持续的撞击,最终会发生骨关节炎。由此早期的诊断及手术干预,可以消除疼痛,防止骨关节炎的发生。进而推迟或消除关节置换手术是有巨大的经济和社会价值。  相似文献   

12.
Dysplasia of the human hip is characterised by insufficient anterolateral covering of femoral head by the acetabulum. In our study, we evaluated dysplastic human hip joints using biomechanical parameters (the peak contact stress in the weight-bearing area of the hip - pmax) and X-ray image parameters (the centre-edge angle - thetaCE, the transverse acetabular inclination angle - thetaUS, the acetabular index of the weight-bearing zone - thetaAC, the ACM angle - thetaACM, and the hip value - HV). The purpose of this study is to make use of X-ray and biomechanical parameters to evaluate hips diagnosed with "hip dysplasia", and to establish whether or not there is a correlation between the two. Our results show a statistically significant correlation between pmax and thetaCE, thetaUS and thetaAC. The correlation between pmax and thetaACM and HV is not statistically significant.  相似文献   

13.
A new bio-tribological simulator system was designed and built for basic wear tests on artificial hip joint materials and for common tribological studies applications. The module of hip joint simulator is consisted of Flexion and Extension (FE), Abduction and Adduction (AA) and Internal and External Rotation (IER). Preliminary tests were done with a 28 mm CoCrMo femoral head and a Ultra High Molecular Weight Polyethylene (UHMWPE) cup. Results showed that the wear rate was close to the clinical one. A frequency control system and a heating system were developed to offer a wide range of rotation frequency and temperature so as to provide proper experiments. In the Pin-on-Disk (POD) part, eight precision-made pins were generated and an advanced computer system was built up to measure the friction coefficient of the tests samples.  相似文献   

14.
In morphological analysis of the femur, the hip joint centre (HJC) is generally determined using a 3D model of the femoral head based on medical images. However, the portion of the image selected to represent the femoral head may influence the HJC. We determined if this influence invalidates the results of three HJC calculation methods, one of which we introduce here.

To isolate femoral heads in cadaver CT images, thresholds were applied to the distance between femur and acetabulum models. The sensitivity of the HJC to these thresholds and the differences between methods were quantified.

For thresholds between 6 and 9 mm and healthy hips, differences between methods were below 1 mm and all methods were insensitive to threshold changes. For higher thresholds, the fovea capitis femoris disturbed the HJC. In two deformed hips, the new method performed superiorly. We conclude that for normal hips all methods produce valid results.  相似文献   

15.
In morphological analysis of the femur, the hip joint centre (HJC) is generally determined using a 3D model of the femoral head based on medical images. However, the portion of the image selected to represent the femoral head may influence the HJC. We determined if this influence invalidates the results of three HJC calculation methods, one of which we introduce here. To isolate femoral heads in cadaver CT images, thresholds were applied to the distance between femur and acetabulum models. The sensitivity of the HJC to these thresholds and the differences between methods were quantified. For thresholds between 6 and 9?mm and healthy hips, differences between methods were below 1?mm and all methods were insensitive to threshold changes. For higher thresholds, the fovea capitis femoris disturbed the HJC. In two deformed hips, the new method performed superiorly. We conclude that for normal hips all methods produce valid results.  相似文献   

16.
The life span of a total hip prosthesis is one of the main points on which the long-term success of arthroplasties depends. It is, by now, widely recognized that hip arthroplasty failure is mainly due to the aseptic loosening resulting from the presence of wear debris forming at the contact interface between the femoral head and the cup of the acetabulum. The size of these particles varies from a few micrometers to some tens of micrometers or more. The main aim of this study was therefore to investigate the formation of debris in the microscopic size range. For this purpose, a numerical study was carried out on various mechanisms leading to plastic deformations, which can lead to damage and wear in material. Numerical analyses were performed with a laboratory software program LMGC90, on the evolution of the plastic strains involved in various wear mechanisms on the microscopic scale.  相似文献   

17.
When walking long distances, hip prostheses heat up due to friction. The influence of articulating materials and lubricating properties of synovia on the final temperatures, as well as any potential biological consequences, are unknown. Such knowledge is essential for optimizing implant materials, identifying patients who are possibly at risk of implant loosening, and proving the concepts of current joint simulators. An instrumented hip implant with telemetric data transfer was developed to measure the implant temperatures in vivo. A clinical study with 100 patients is planned to measure the implant temperatures for different combinations of head and cup materials during walking. This study will answer the question of whether patients with synovia with poor lubricating properties may be at risk for thermally induced bone necrosis and subsequent implant failure. The study will also deliver the different friction properties of various implant materials and prove the significance of wear simulator tests. A clinically successful titanium hip endoprosthesis was modified to house the electronics inside its hollow neck. The electronics are powered by an external induction coil fixed around the joint. A temperature sensor inside the implant triggers a timer circuit, which produces an inductive pulse train with temperature-dependent intervals. This signal is detected by a giant magnetoresistive sensor fixed near the external energy coil. The implant temperature is measured with an accuracy of 0.1°C in a range between 20°C and 58°C and at a sampling rate of 2-10 Hz. This rate could be considerably increased for measuring other data, such as implant strain or vibration. The employed technique of transmitting data from inside of a closed titanium implant by low frequency magnetic pulses eliminates the need to use an electrical feedthrough and an antenna outside of the implant. It enables the design of mechanically safe and simple instrumented implants.  相似文献   

18.
Joint simulators are important tools in wear studies of prosthetic joint materials. The type of motion in a joint simulator is crucial with respect to the wear produced. It is widely accepted that only multidirectional motion yields realistic wear for polyethylene acetabular cups. Multidirectionality, however, is a wide concept. The type of multidirectional motion varies considerably between simulators, which may explain the large differences in observed wear rates. At present, little is known about the relationship between the type of multidirectional motion and wear. One illustrative way to compare the motions of various hip simulators is to compute tracks made on the counterface by selected points of the surface of the femoral head and acetabular cup due to the cyclic relative motion. A new computation method, based on Euler angles, was developed, and used to compute slide tracks for the three-axis motion of the hip joint in walking, and for two hip simulators, the HUT-3 and the biaxial rocking motion. The slide track patterns resulting from the gait waveforms were found to be similar to those produced by the HUT-3 simulator. This paper is the first to include a verification of the computed simulator tracks. The tracks were verified in the two simulators using sharp pins, embedded in acetabular cups, engraving distinct grooves onto the femoral heads. The engravings were identical to the computed tracks. The results clearly differed from earlier computations by another research group. This study is intended to start a thorough investigation of the relationship between the type of multidirectional motion and wear.  相似文献   

19.
The goal of this study was to investigate the influence of the acetabular labrum on the consolidation, and hence the solid matrix strains and stresses, of the cartilage layers of the hip joint. A plane-strain finite element model was developed, which represented a coronal slice through the acetabular and femoral cartilage layers and the acetabular labrum. Elements with poroelastic properties were used to account for the biphasic solid/fluid nature of the cartilage and labrum. The response of the joint over an extended period of loading (10,000s) was examined to simulate the nominal compressive load that the joint is subjected to throughout the day. The model demonstrated that the labrum adds an important resistance in the flow path of the fluid being expressed from the cartilage layers of the joint. Cartilage layer consolidation was up to 40% quicker in the absence of the labrum. Following removal of the labrum from the model, the solid-on-solid contact stresses between the femoral and acetabular cartilage layers were greatly increased (up to 92% higher), which would increase the friction between the joint surfaces. In the absence of the labrum, the centre of contact shifted towards the acetabular rim. Subsurface strains and stresses were much higher without the labrum, which could contribute to fatigue damage of the cartilage layers. Finally, the labrum provided some structural resistance to lateral motion of the femoral head within the acetabulum, enhancing joint stability and preserving joint congruity.  相似文献   

20.
The life span of a total hip prosthesis is one of the main points on which the long-term success of arthroplasties depends. It is, by now, widely recognized that hip arthroplasty failure is mainly due to the aseptic loosening resulting from the presence of wear debris forming at the contact interface between the femoral head and the cup of the acetabulum. The size of these particles varies from a few micrometers to some tens of micrometers or more. The main aim of this study was therefore to investigate the formation of debris in the microscopic size range. For this purpose, a numerical study was carried out on various mechanisms leading to plastic deformations, which can lead to damage and wear in material. Numerical analyses were performed with a laboratory software program LMGC90, on the evolution of the plastic strains involved in various wear mechanisms on the microscopic scale.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号