Two-dimensional, finite element studies were conducted of the proximal tibia before and after joint arthroplasty. Equivalent-thickness models projected onto the mid-frontal plane were created for the natural, proximal tibia and for the proximal tibia with four different types of tibial plateau components. All components simulated bony ingrowth fixation, i.e. no cement layer existed between component and bone. In addition, the interface between component and bone was assumed to be intimately connected, representing complete bony ingrowth and a rigid state of fixation. Loads consisted of bi-condylar and uni-condylar forces. Results indicated that conventional plateau designs with central posts or multiple pegs led to higher stress magnitudes in the trabecular bone near the distal ends of the post/pegs and stress shielding at more proximal locations. A design without posts or pegs whose interface geometry mimics the epiphyseal plate minimizes bone stress shielding. An implant consisting of separate components covering each condyle was found effective in limiting component tilting and the consequent tensile stresses caused by non-symmetrical, uni-condylar loading.  相似文献   

2.
Failure of total knee arthroplasty is relatively often caused by problems of the patellofemoral replacement. The purpose of this study was to analyze the distribution of stresses within an anatomical patella and the changes in stress distribution after patellar resurfacing with a Miller-Galante I patellar implant using two- and three dimensional finite element models (FEM). To assess validity, FEM results were compared with morphological findings from contact radiographs and densitographs. Internal orientation of bone trabeculae is in good agreement with the orientation of theoretically calculated principal stresses. Almost unchanged principal tensile stresses after implantation, together with the lack of extreme stress peaks within the cancellous bone ensure stress compatibility of the implant. In the case of a firmly seated implant with good bone ingrowth, increased von Mises stresses are found near the fixation peg/plate junction. Their relevance for improved bone ingrowth near this part of the interface is emphasized. At the same time, material failure at the peg/plate junction can be better understood. An analysis of the early postoperative period assuming nonlinear interface conditions failed to demonstrate an uniform distribution of normal and tangential interface forces.  相似文献   

3.
Finite element stress analyses were conducted of the canine femoral head before and after implantation of various surface replacement-type components. The femoral head was replaced by four implant geometries; (a) shell, (b) shell with peg, (c) shell with rod, and (d) a new epiphyseal replacement design. All implants were modelled to simulate bony ingrowth along the underside of the shell and along the surfaces of the peg and rod. The results indicated that in the normal femur the forces are transferred from the articular surface through the femoral head cancellous bone to the inferior cortical shell of the femoral neck. After shell-type surface replacement, forces were transferred more distally at the rim of the shell and at the end of the peg or rod, thereby reducing the stresses in the proximal head cancellous bone. Computer simulation of bone remodelling due to proximal bone stress reduction was shown to accentuate the abnormality of the stress fields. Surface replacement with a lower modulus material created a less abnormal redistribution of bone stresses. The new epiphyseal replacement design resulted in stress distributions similar to those in the normal femoral head and minimal shear stresses at the implant/bone interface. These findings suggest that the epiphyseal replacement concept may provide better initial mechanical integrity and create a more benign milieu for adaptive bone remodelling than conventional, shell-type surface replacement components.  相似文献   

4.
Periprosthetic bone resorption after tibial prosthesis implantation remains a concern for long-term fixation performance. The fixation techniques may inherently aggravate the "stress-shielding" effect of the implant, leading to weakened bone foundation. In this study, two cemented tibial fixation cases (fully cemented and hybrid cementing with cement applied under the tibial tray leaving the stem uncemented) and three cementless cases relying on bony ingrowth (no, partial and fully ingrown) were modelled using the finite element method with a strain-adaptive remodelling theory incorporated to predict the change in the bone apparent density after prosthesis implantation. When the models were loaded with physiological knee joint loads, the predicted patterns of bone resorption correlated well with reported densitometry results. The modelling results showed that the firm anchorage fixation formed between the prosthesis and the bone for the fully cemented and fully ingrown cases greatly increased the amount of proximal bone resorption. Bone resorption in tibial fixations with a less secure anchorage (hybrid cementing, partial and no ingrowth) occurred at almost half the rate of the changes around the fixations with a firm anchorage. The results suggested that the hybrid cementing fixation or the cementless fixation with partial bony ingrowth (into the porous-coated prosthesis surface) is preferred for preserving proximal tibial bone stock, which should help to maintain post-operative fixation stability. Specifically, the hybrid cementing fixation induced the least amount of bone resorption.  相似文献   

5.
A three-dimensional finite element analysis of the upper tibia   总被引:1,自引:0,他引:1  
A three-dimensional finite element model of the proximal tibia has been developed to provide a base line for further modeling of prosthetic resurfaced tibiae. The geometry for the model was developed by digitizing coronal and transverse sections made with the milling machine, from one fresh tibia of average size. The load is equally distributed between the medial and lateral compartments over contact areas that were reported in the literature. An indentation test has been used to measure the stiffness and the ultimate strength of cancellous bone in four cadaver tibiae. These values provided the statistical basis for characterising the inhomogeneous distribution of the cancellous bone properties in the proximal tibia. All materials in the model were assumed to be linearly elastic and isotropic. Mechanical properties for the cortical bone and cartilage have been taken from the literature. Results have been compared with strain gage tests and with a two-dimensional axisymmetric finite element model both from the literature. Qualitative comparison between trabecular alignment, and the direction of the principal compressive stresses in the cancellous bone, showed a good relationship. Maximum stresses in the cancellous bone and cortical bone, under a load which occurs near stance phase during normal gait, show safety factors of approximately eight and twelve, respectively. The load sharing between the cancellous bone and the cortical bone has been plotted for the first 40 mm distally from the tibial eminence.  相似文献   

6.
Theoretical concerns about the use of cemented or press-fit stems in revision total knee arthroplasty (TKA) include stress shielding with adverse effects on prosthesis fixation. Revision TKA components are commonly stemmed to protect the limited autogenous bone stock remaining. Revision procedures with the use of stems can place abnormal stresses through even normal bone by their constrained design, type of materials and fixation method and may contribute for bone loss. Experimental quantification of strain shielding in the proximal synthetic tibia following TKA is the main purpose of the present study. In this study, cortical bone strains were measured experimentally with tri-axial strain gauges in synthetic tibias before and after in vitro knee surgery. Three tibias were implanted with cemented and press-fit stem augments and solely with a tibial tray (short monobloc stem) of the P.F.C. Sigma Modular Knee System. The difference between principal strains of the implanted and the intact tibia was calculated for each strain gauge position. The results demonstrated a pronounced strain-shielding effect in the proximal level, close to tibial tray with the cemented stem augment. The press-fit stem presented a minor effect of strain shielding but was more extensively throughout the stem. An increase of strains closely to the distal tip of the cemented and the press-fit stem augment was observed. This suggests for a physiological condition, a potential effect of bone resorption at the proximal region for the cemented stem augment. The localized increase of strains in stems tip can be related with the clinical finding of the pain, at the end of stem after revision TKA.  相似文献   

7.
Malalignment is the main cause of tibial component loosening. Implants that migrate rapidly in the first two post-operative years are likely to present aseptic loosening. It has been suggested that cancellous bone stresses can be correlated with tibial component migration. A recent study has shown that patient-specific finite element (FE) models have the power to predict the short-term behavior of tibial trays. The stresses generated within the implanted tibia are dependent on the kinematics of the joint; however, previous studies have ignored the kinematics and only applied static loads. Using explicit FE, it is possible to simultaneously predict the kinematics and stresses during a gait cycle. The aim of this study was to examine the cancellous bone strains during the stance phase of the gait cycle, for varying degrees of varus/valgus eccentric loading using explicit FE. A patient-specific model of a proximal tibia was created from CT scan images, including heterogeneous bone properties. The proximal tibia was implanted with a commercial total knee replacement (TKR) model. The stance phase of gait was simulated and the applied loads and boundary conditions were based on those used for the Stanmore knee simulator. Eccentric loading was simulated. As well as examining the tibial bone strains (minimum and maximum principal strain), the kinematics of the bone-implant construct are also reported. The maximum anterior-posterior displacements and internal-external rotations were produced by the model with 20 mm offset. The peak minimum and maximum principal strain values increased as the load was shifted laterally, reaching a maximum magnitude for -20 mm offset. This suggests that when in varus, the load transferred to the bone is shifted medially, and as the bone supporting this load is stiffer, the resulting peak bone strains are lower than when the load is shifted laterally (valgus). For this particular patient, the TKR design analyzed produced the highest cancellous bone strains when in valgus. This study has provided an insight in the variations produced in bone strain distribution when the axial load is applied eccentrically. To the authors' knowledge, this is the first time that the bone strain distribution of a proximal implanted tibia has been examined, also accounting for the kinematics of the tibio-femoral joint as part of the simulation. This approach gives greater insight into the overall performance of TKR.  相似文献   

8.
Effect of initial interference fit on pull-out strength in cementless fixation between bovine tibia and smooth stainless steel post was investigated in this study.Compressive behavior of bovine spongious bone was studied using mechanical testing in order to evaluate the elastic-plastic properties in different regions of the proximal tibia.Friction tests were carried out in the aim to evaluate the friction behavior of the contact between bovine spongious bone and stainless steel.A cylindrical stainless steel post inserted in a pre-drilled bovine tibia with an initial interference fit was taken as an in vitro model to assess the contribution of post fixation to the initial stability of the Total Knee Arthroplasty (TKA) tibial component.Pull-out experiments were carried out for different initial interference fits.Finite Element Models (FEM) using local elastic-plastic properties of the bovine bone were developed for the analysis of the experimental ultimate pull-out force results.At the post/bone interface,Coulomb friction was considered in the FEM calculations with pressure-dependent friction coefficient.It was found that the FEM results of the ultimate force are in good agreement with the experimental results.The analysis of the FEM interfacial stresses indicates that the micro-slip initiation depends on the local bone properties.  相似文献   

9.
Although adult skeletal morphological variation is best understood within the framework of age-related processes, relatively little research has been directed towards the structure of and variation in trabecular bone during ontogeny. We report here new quantitative and structural data on trabecular bone microarchitecture in the proximal tibia during growth and development, as demonstrated in a subadult archaeological skeletal sample from the Late Prehistoric Ohio Valley. These data characterize the temporal sequence and variation in trabecular bone structure and structural parameters during ontogeny as related to the acquisition of normal functional activities and changing body mass. The skeletal sample from the Fort Ancient Period site of SunWatch Village is composed of 33 subadult and three young adult proximal tibiae. Nondestructive microCT scanning of the proximal metaphyseal and epiphyseal tibia captures the microarchitectural trabecular structure, allowing quantitative structural analyses measuring bone volume fraction, degree of anisotropy, trabecular thickness, and trabecular number. The microCT resolution effects on structural parameters were analyzed. Bone volume fraction and degree of anisotropy are highest at birth, decreasing to low values at 1 year of age, and then gradually increasing to the adult range around 6-8 years of age. Trabecular number is highest at birth and lowest at skeletal maturity; trabecular thickness is lowest at birth and highest at skeletal maturity. The results of this study highlight the dynamic sequential relationships between growth/development, general functional activities, and trabecular distribution and architecture, providing a reference for comparative studies.  相似文献   

10.
In this paper we introduce the concept of the functional (or equivalent) geometry of the knee, which is an attempt to reduce the natural knee with its complex geometry, frictional resistance and deformable cartilage into a two-dimensional joint comprising rigid femur and tibia in frictionless contact. An apparatus and method are described to measure the slope of the tangent to the surfaces of the 'equivalent' bones at their 'point' of contact. An antero posterior force of +/-300-500 N and axial compressive load of twice body weight were applied on cadaveric knee joints. The corresponding displacement of the tibia in the saggital plane was measured firstly with both cruciates intact and then when each was severed in turn. From the data obtained both the slope of the tangent mentioned above and the tensions developed along the cruciates under the influence of the forces applied were calculated. The results showed that the functional geometry of the knee in the saggital plane can be represented by a convex femur and a concave tibia. The tensions along the cruciates calculated on the basis of the experimental measurements were nearly always lower than the antero posterior force applied, and although this corroborated the trend demonstrated in a previous theoretical analysis, they were lower still. The reason for this may be the deformation of the cartilage under load, thus modifying the geometry of contact resulting in a more concave tibia of the 'equivalent' knee joint, than that of the rigid model used in the theoretical analysis.  相似文献   

11.
Bone loss from the paralysed limbs after spinal cord injury (SCI) is well documented. Under physiological conditions, bones are adapted to forces which mainly emerge from muscle pull. After spinal cord injury (SCI), muscles can no longer contract voluntarily and are merely activated during spasms. Based on the Ashworth scale, previous research has suggested that these spasms may mitigate bone losses. We therefore wished to assess muscle forces after SCI with a more direct measure and compare it to measures of bone strength. We hypothesized that the bones in SCI patients would be in relation to the loss of muscle forces. Six male patients with SCI 6.4 (SD 4.3) years earlier and 6 age-matched, able-bodied control subjects were investigated. Bone scans from the right knee were obtained by pQCT. The knee extensor muscles were electrically stimulated via the femoral nerve, isometric knee extension torque was measured and patellar tendon force was estimated. Tendon force upon electrical stimulation in the SCI group was 75% lower than in the control subjects (p<0.01). Volumetric bone mineral density of the patella and of the proximal tibia epiphysis were 50% lower in the SCI group than in the control subjects (p<0.01). Cortical area was lower by 43% in the SCI patients at the proximal tibia metaphysis, and by 33% at the distal femur metaphysis. No group differences were found in volumetric cortical density. Close curvilinear relationships were found between stress and volumetric density for the tibia epiphysis (r(2)=0.90) and for the patella (r(2)=0.91). A weaker correlation with the tendon force was found for the cortical area of the proximal tibia metaphysis (r(2)=0.63), and none for the distal femur metaphysis. These data suggest that, under steady state conditions after SCI, epiphyseal bones are well adapted to the muscular forces. For the metaphysis of the long bones, such an adaptation appears to be less evident. The reason for this remains unclear.  相似文献   

12.
Loosening and migration of tibial prostheses have been identified as causes of early total knee replacement (TKR) failure. The problem is made more complex when defects occur in the proximal tibia compromising fixation and alignment. Clinical studies using metal augments have shown these to be an alternative to other means of defect treatment. Finite element (FE) analysis can be used to identify regions that may be prone to loosening and migration. In the current work, 3D FE models of TKR uncontained type-2 defects treated with block augments have been constructed and analysed. It has been shown that a metal augment is the most suitable. The use of bone cement (PMMA) to fill proximal defects is not considered suitable as stresses carried by the cement block exceed those of the fatigue limit of bone cement. It has been shown that the stresses in the proximal cancellous bone of block-augmented models are significantly below levels likely to cause damage due to overloading. Furthermore, the use of stem extensions has been shown to reduce the cancellous bone stresses in the proximal region thus increasing the likelihood of bone resorption. Given this, it is recommended that stem extensions are not required unless necessary to mitigate some other problem.  相似文献   

13.
Glenoid component loosening is the dominant cause of failure in total shoulder arthroplasty. It is presumed that loosening in the glenoid is caused by high stresses in the cement layer. Several anchorage systems have been designed with the aim of reducing the loosening rate, the two major categories being "keeled" fixation and "pegged" fixation. However, no three-dimensional finite element analysis has been performed to quantify the stresses in the cement or to compare the different glenoid prosthesis anchorage systems. The objective of this study was to determine the stresses in the cement layer and surrounding bone for glenoid replacement components. A three-dimensional model of the scapula was generated using CT data for geometry and material property definition. Keeled and pegged designs were inserted into the glenoid, surrounded by a 1-mm layer of bone cement. A 90 deg arm abduction load with a full muscle and joint load was applied, following van der Helm (1994). Deformations of the prosthesis, stresses in the cement, and stresses in the bone were calculated. Stresses were also calculated for a simulated case of rheumatoid arthritis (RA) in which bone properties were modified to reflect that condition. A maximum principal stress-based failure model was used to predict what quantity of the cement is at risk of failure at the levels of stress computed. The prediction is that 94 percent (pegged prosthesis) and 68 percent (keeled prosthesis) of the cement has a greater than 95 percent probability of survival in normal bone. In RA bone, however, the situation is reversed where 86 percent (pegged prosthesis) and 99 percent (keeled prosthesis) of the cement has a greater than 95 percent probability of survival. Bone stresses are shown to be not much affected by the prosthesis design, except at the tip of the central peg or keel. It is concluded that a "pegged" anchorage system is superior for normal bone, whereas a "keeled" anchorage system is superior for RA bone.  相似文献   

14.
A three-dimensional model of the knee is developed to study the interactions between the muscles, ligaments, and bones during activity. The geometry of the distal femur, proximal tibia, and patella is based on cadaver data reported for an average-size knee. The shapes of the femoral condyles are represented by high-order polynomials; the tibial plateaux and patellar facets are approximated as flat surfaces. The contacting surfaces of the femur and tibia are modeled as deformable, while those of the femur and patella are assumed to be rigid. Interpenetration of the femur and tibia is taken into account by modeling cartilage as a thin, linear, elastic layer, mounted on rigid bone. Twelve elastic elements describe the geometry and mechanical properties of the cruciate ligaments, the collateral ligaments, and the posterior capsule. The model is actuated by thirteen musculotendinous units, each unit modeled as a three-element muscle in series with tendon. The path of each muscle is approximated as a straight line, except where it contacts and wraps around bone and other muscles; changes in muscle paths are taken into account using data obtained from MRI. In the first part of this paper, the model is used to simulate passive knee flexion. Quantitative comparisons of the model results with experimental data reported in the literature indicate that the relative movements of the bones and the geometry of the ligaments and muscles in the model are similar to those evident in the real knee. In Part II, the model is used to describe knee-ligament function during anterior-posterior draw, axial rotation, and isometric knee-extension and knee-flexion exercises.  相似文献   

15.
A three-dimensional model of the knee is developed to study the interactions between the muscles, ligaments, and bones during activity. The geometry of the distal femur, proximal tibia, and patella is based on cadaver data reported for an average-size knee. The shapes of the femoral condyles are represented by high-order polynomials: the tibial plateaux and patellar facets are approximated as flat surfaces. The contacting surfaces of the femur and tibia are modeled as deformable, while those of the femur and patella are assumed to be rigid. Interpenetration of the femur and tibia is taken into account by modeling cartilage as a thin, linear, elastic layer, mounted on rigid bone. Twelve elastic elements describe the geometry and mechanical properties of the cruciate ligaments, the collateral ligaments, and the posterior capsule. The model is actuated by thirteen musculotendinous units, each unit modeled as a three-element muscle in series with tendon. The path of each muscle is approximated as a straight line, except where it contacts and wraps around bone and other muscles; changes in muscle paths are taken into account using data obtained from MRI. In the first part of this paper, the model is used to simulate passive knee flexion. Quantitative comparisons of the model results with experimental data reported in the literature indicate that the relative movements of the bones and the geometry of the ligaments and muscles in the model are similar to those evident in the real knee. In Part II, the model is used to describe knee-ligament function during anterior-posterior draw, axial rotation, and isometric knee-extension and knee-flexion exercises.  相似文献   

16.
The objective of this investigation was to examine the stress-morphology relationships for trabecular bone around implants with different surface characteristics. Stainless steel spheres with either a polished surface or a sintered-bead porous coating were implanted unilaterally into equine patellae and maintained for a 6 month period. Stereological methods were used to quantify the trabecular bone morphology and finite element analyses were performed to predict the trabecular bone stresses. In general, the remodeling response around the smooth implants was greater than that around those porous implants that exhibited bone ingrowth. In accordance with these differences, the finite element models predicted greater changes in the stresses adjacent to the smooth implants due to the nonlinear boundary conditions. However, it did not appear that the trajectorial theory, in its simplest form, was applicable to the remodeling induced by the implants. A linear relationship between the change in bone areal density and the change in von Mises effective stress provides support for the hypothesis that the architecture of trabecular bone corresponds to an optimal structure. The results also demonstrated that, under certain circumstances, small changes in the stress state may result in large changes in the principal material orientation.  相似文献   

17.
Ligament-bone interaction in a three-dimensional model of the knee   总被引:1,自引:0,他引:1  
In mathematical knee-joint models, the ligaments are usually represented by straight-line elements, connecting the insertions of the femur and tibia. Such a model may not be valid if a ligament is bent in its course over bony-surfaces, particularly not if the resulting redirection of the ligament force has a considerable effect on the laxity or motion characteristics of the knee-joint model. In the present study, a model for wrapping of a ligament around bone was incorporated in a three-dimensional mathematical model of the human knee. The bony edge was described by a curved line on which the contact point of the line element representing a ligament bundle was located. Frictionless contact between the ligament bundle and the bone was assumed. This model was applied to the medial collateral ligament (MCL) interacting with the bony edge of the tibia. It was found that, in comparison with the original model without bony interactions, the bony edge redirected the ligament force of the MCL in such a way that it counterbalanced valgus moments on the tibia more effectively. The effect of the bony interaction with the MCL on the internal-external rotation laxity, however, was negligible.  相似文献   

18.
Patellar resurfacing during knee replacement is still under debate, with several studies reporting higher incidence of anterior knee pain in unresurfaced patellae. Congruency between patella and femur impacts the mechanics of the patellar cartilage and strain in the underlying bone, with higher stresses and strains potentially contributing to cartilage wear and anterior knee pain. The material properties of the articulating surfaces will also affect load transfer between femur and patella. The purpose of this study was to evaluate the mechanics of the unresurfaced patella and compare with natural and resurfaced conditions in a series of finite element models of the patellofemoral joint. In the unresurfaced analyses, three commercially available implants were compared, in addition to an 'ideal' femoral component which replicated the geometry, but not the material properties, of the natural femur. Hence, the contribution of femoral component material properties could be assessed independently from geometry changes. The ideal component tracked the kinematics and patellar bone strain of the natural knee, but had consistently inferior contact mechanics. In later flexion, compressive patellar bone strain in unresurfaced conditions was substantially higher than in resurfaced conditions. Understanding how femoral component geometry and material properties in unresurfaced knee replacement alters cartilage contact mechanics and bone strain may aid in explaining why the incidence of anterior knee pain is higher in the unresurfaced population, and ultimately contribute to identifying criteria to pre-operatively predict which patients are suited to an unresurfaced procedure and reducing the incidence of anterior knee pain in the unresurfaced patient population.  相似文献   

19.
A three-dimensional model of the knee is used to study ligament function during anterior-posterior (a-p) draw, axial rotation, and isometric contractions of the extensor and flexor muscles. The geometry of the model bones is based on cadaver data. The contacting surfaces of the femur and tibia are modeled as deformable; those of the femur and patella are assumed to be rigid. Twelve elastic elements are used to describe the geometry and mechanical properties of the cruciate ligaments, the collateral ligaments, and the posterior capsule. The model is actuated by thirteen musculotendinous units, each unit represented as a three-element muscle in series with tendon. The calculations show that the forces applied during a-p draw are substantially different from those applied by the muscles during activity. Principles of knee-ligament function based on the results of in vitro experiments may therefore be overstated. Knee-ligament forces during straight a-p draw are determined solely by the changing geometry of the ligaments relative to the bones: ACL force decreases with increasing flexion during anterior draw because the angle between the ACL and the tibial plateau decreases as knee flexion increases; PCL force increases with increasing flexion during posterior draw because the angle between the PCL and the tibial plateau increases. The pattern of ligament loading during activity is governed by the geometry of the muscles spanning the knee: the resultant force in the ACL during isometric knee extension is determined mainly by the changing orientation of the patellar tendon relative to the tibia in the sagittal plane; the resultant force in the PCL during isometric knee flexion is dominated by the angle at which the hamstrings meet the tibia in the sagittal plane.  相似文献   

20.
Subchondral stiffening is a hallmark pathologic feature of osteoarthritis but its mechanical and temporal relationship to the initiation or the progression of osteoarthritis is not established. The mechanical effect of subchondral stiffening on the surrounding trabecular bone is poorly understood. This study employs a relatively new application of digital image correlation to measure strain in the trabecular region of the proximal medial tibia in normal specimens and in specimens with simulated subchondral bone stiffening. Coronal sections from eight normal human cadaveric proximal tibiae were loaded in static compression and high resolution contact radiographs were made. Repeat contact radiographs were collected after the subchondral bone near the jointline was stiffened using polymethylmethacrylate. Digital images, made from loaded and unloaded contact radiographs, were compared using in-house software to measure trabecular displacement and calculate trabecular bone strain. Overall strain was higher in the stiffened specimens suggesting experimental artifiact significantly affected our results. Consistent increases in median maximum shear strain, median maximum principal strain, median minimum principal strain, and peak shear strain were measured near the inner and outer edges of the stiffened segment. Our experiment provides direct experimental measurement of increases in trabecular bone strain caused by subchondral stiffening, however, the clinical and biologic importance of strain increases is unknown.  相似文献   