首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 265 毫秒
1.
A highly sensitivity liquid chromatography–tandem mass spectrometry method has been developed for the quantitation of sodium cromoglycate (SCG) in human plasma. The method was validated over a linear range of 0.100–50.0 ng/ml, using 13C4 sodium cromoglycate as the internal standard. Compounds were extracted from 1.0 ml of lithium heparin plasma by methanol elution of C18 solid-phase extraction cartridges. The dried residue was reconstituted with 100 μl of 0.01 N HCl, and 30 μl was injected onto the LC–MS–MS system. Chromatographic separation was achieved on a C8 (3.5 μm) column with an isocratic mobile phase of methanol–water–0.5 M ammonium acetate (35:64.8:0.2, v/v/v). The analytes were detected with a PE Sciex API 3000 mass spectrometer using turbo ion spray with positive ionization. Ions monitored in the multiple reaction monitoring (MRM) mode were m/z 469.2 (precursor ion) to m/z 245.1 (product ion) for SCG and m/z 473.2 (precursor ion) to m/z 247.1 (product ion) for 13C4 SCG (I.S.). The average recoveries of SCG and the I.S. from human plasma were 91 and 87%, respectively. The low limit of quantitation was 0.100 ng/ml. Results from a 4-day validation study demonstrated excellent precision (C.V.% values were between 1.9 and 6.5%) and accuracy (−5.4 to −1.2%) across the calibration range of 0.100–50.0 ng/ml.  相似文献   

2.
Direct, quantitative capillary electrophoresis–electrospray ionisation mass spectrometric (CE–ESI-MS) and tandem mass spectrometric (CE–ESI-MS–MS) methods are described for the quantitation of 3-O-glucuronides of E- and Z-entacapone isomers (EEG and EZG) and tolcapone (TG) in urine. 3-O-Glucuronide of nitecapone was used as internal standard. Good separation of glucuronides was achieved with 20 mM ammonium acetate as separation solution at pH 6.84. Stacking was used to increase the sensitivity of the method by introducing samples in 5 mM ammonium acetate. CE–ESI-MS and CE–ESI-MS–MS methods are linear with correlation coefficients better than 0.9983 and 0.9982, and repeatable with relative standard deviations below 9 and 14%, respectively. The limit of detection (LOD) in CE–ESI-MS at signal-to-noise ratio 3 is 100 ng/ml for EEG and EZG and 250 ng/ml for TG. The CE–ESI-MS–MS method was the more sensitive; LOD was 7 ng/ml for all compounds, without any concentration of the sample.  相似文献   

3.
A sensitive, specific and reproducible method for the quantitative determination of stanozolol in human hair has been developed. The sample preparation involved a decontamination step of the hair with methylene chloride and the sonication in methanol of 100 mg of powdered hair for 2 h. After elimination of the solvent, the hair sample was solubilized in 1 ml 1 M NaOH, 15 min at 95°C, in the presence of 10 ng stanozolol-d3 used as internal standard. The homogenate was neutralized and extracted using consecutively a solid-phase (Isolute C18) and a liquid–liquid (pentane) extraction. After evaporation of the final organic phase, the dry extract was derivatized using 40 μl MBHFA–TMSI (1000:20, v/v), incubated for 5 min at 80°C, followed by 10 μl of MBHFBA, incubated for 30 min at 80°C. The derivatized extract was analyzed by a Hewlett-Packard GC–MS system with a 5989 B Engine operating in the negative chemical ionization mode of detection. Linearity of the detector response was observed for stanozolol concentrations ranging from 5 to 200 pg/mg with a correlation coefficient of 0.998. The assay was capable of detecting 2 pg of stanozolol per mg of hair when approximately 100 mg hair material was processed, with a quantification limit set at 5 pg/mg. Intra-day precision was 5.9% at 50 pg/mg and 7.8% at 25 pg/mg with extraction recoveries of 79.8 and 75.1%, respectively. The analysis of a 3-cm long hair strand, obtained from a young bodybuilder (27 year old) assuming to be a regular user of Winstrol (stanozolol, 2 mg), revealed the presence of stanozolol at the concentration of 15 pg/mg.  相似文献   

4.
An analytical procedure to screen butorphanol in horse race urine using ELISA kits and its confirmation by GC–MS is described. Urine samples (5 ml) were subjected to enzymatic hydrolysis and extracted by solid-phase extraction. The residues were then evaporated, derivatized and injected into the GC–MS system. The ELISA test (20 μl of sample) was able to detect butorphanol up to 104 h after the intramuscular administration of 8 mg of Torbugesic, and the GC–MS method detected the drug up to 24 h in FULL SCAN or 31 h in the SIM mode. Validation of the GC–MS method in the SIM mode using nalbuphine as internal standard included linearity studies (10–250 ng/ml), recovery (±100%), intra-assay (4.1–14.9%) and inter-assay (9.3–45.1%) precision, stability (10 days), limit of detection (10 ng/ml) and limit of quantitation (20 ng/ml).  相似文献   

5.
This report describes a specific and highly sensitive gas chromatography–mass spectrometry (GC–MS) assay for the analysis of industrially produced 2-hydroxypropyl-γ-cyclodextrin, a heterogeneous mixture of homologues and isomers, in plasma of cynomolgus monkeys. Instead of analyzing the polysaccharide mixture as a whole, in a first step the HP-γ-cyclodextrin mixture, together with the internal standard (2,6-di-O-methyl-β-cyclodextrin), was deuteromethylated, and in a second step hydrolyzed with hydrochloric acid to the respective monosaccharides. The resulting reaction mixture was trimethylsilylated to 1,4-bis(O-trimethylsilyl)-2,3-bis-O-deuteromethyl-6-O-2′-deuteromethoxypropylglucose (representative for HP-γ-CD) and 1,4-bis-(O-trimethylsilyl)-bis-2,6-O-methyl-3-O-deuteromethylglucose (representative for the internal standard), respectively, and analyzed by GC–MS. The limit of quantification of this assay was 20 nmol/l.  相似文献   

6.
A selective gas–liquid chromatographic method with mass spectrometry (GC–MS) for the simultaneous confirmation and quantification of ephedrine, pseudo-ephedrine, nor-ephedrine, nor-pseudoephedrine, which are pairs of diastereoisomeric sympathomimetic amines, and methyl-ephedrine was developed for doping control analysis in urine samples. O-Trimethylsilylated and N-mono-trifluoroacetylated derivatives of ephedrines — one derivative was formed for each ephedrine — were prepared and analyzed by GC–MS, after alkaline extraction of urine and evaporation of the organic phase, using d3-ephedrine as internal standard. Calibration curves, with r2>0.98, ranged from 3.0 to 50 μg/ml depending on the analyte. Validation data (specificity, % RSD, accuracy, and recovery) are also presented.  相似文献   

7.
For use in clinical studies, a fast and sensitive assay method was developed for the determination of nifedipine in human plasma samples. The assay method is based on tandem mass spectrometry detection (HPLC–MS–MS). The effect of flow injection as well as HPLC separation on the results of the nifedipine determination were evaluated. The limit of quantification is 0.5 ng/ml and the accuracy (as determined by spiking recovery) was found to be good.  相似文献   

8.
We have developed and validated an accurate, sensitive, and rapid high-performance liquid chromatographic–tandem mass spectrometric method (HPLC–MS–MS) for the determination of ethionamide in plasma, bronchoalveolar fluid (BAL) and alveolar cells (AC). The retention times for ethionamide, clemastine fumarate (internal standard for plasma), promethazine (internal standard for plasma) and propranolol (internal standard for BAL and AC) were approximately 2.62, 1.21, 2.14, and 2.22 min, respectively, with a total run time of 3.2 min. Ethionamide detection for plasma was carried out on a PE Sciex API III (Perkin-Elmer, Foster City, CA, USA). BAL and cell pellets and some plasma specimens were analyzed on a Micromass Quattro LC (Micromass Co., Manchester, UK). The detection limits for ethionamide were 0.05 μg/ml for plasma, and 0.005 μg/ml for BAL supernatants and alveolar cell suspensions.  相似文献   

9.
Methods for the determination of 3,4-dichloroaniline (3,4-DCA) and 3,5-dichloroaniline (3,5-DCA) as common markers of eight non-persistent pesticides in human urine are presented. 3,5-DCA is a marker for the exposure to the fungicides vinclozolin, procymidone, iprodione, and chlozolinate. Furthermore the herbicides diuron, linuron, neburon, and propanil are covered using their common marker 3,4-DCA. The urine samples were treated by basic hydrolysis to degrade all pesticides, metabolites, and their conjugates containing the intact moieties completely to the corresponding dichloroanilines. After addition of the internal standard 4-chloro-2-methylaniline, simultaneous steam distillation extraction (SDE) followed by liquid–liquid extraction (LLE) was carried out to produce, concentrate and purify the dichloroaniline moieties. Gas chromatography (GC) with mass spectrometric (MS) and tandem mass spectrometric (MS–MS) detection and also detection with an electron-capture detector (ECD) after derivatisation with heptafluorobutyric anhydride (HFBA) were employed for separation, detection, and identification. Limit of detection of the GC–MS–MS and the GC–ECD methods was 0.03 and 0.05 μg/l, respectively. Absolute recoveries obtained from a urine sample spiked with the internal standard, 3,5-, and 3,4-DCA, ranged from 93 to 103% with 9–18% coefficient of variation. The three detection techniques were compared concerning their performance, expenditure and suitability for their application in human biomonitoring studies. The described procedure has been successfully applied for the determination of 3,4- and 3,5-DCA in the urine of non-occupationally exposed volunteers. The 3,4-DCA levels in these urine samples ranged between 0.13 and 0.34 μg/g creatinine or 0.11 and 0.56 μg/l, while those for 3,5-DCA were between 0.39 and 3.33 μg/g creatinine or 0.17 and 1.17 μg/l.  相似文献   

10.
A method for the quantification of clindamycin in human serum and in human bone tissue samples applying high-performance liquid chromatography with atmospheric pressure chemical ionization–mass spectrometry (APCI–MS) is presented. Lincomycin is used as the internal standard. Serum samples are prepared only by protein precipitation with acetonitrile. Bone tissue samples have to be crushed and homogenized in extraction buffer prior to analysis. The chromatographic separation is achieved on an RP-18 stationary phase with 0.02% trifluoroacetic acid in water 60%/acetonitrile 40% v/v as mobile phase. The limits of quantification are 0.1 μg/ml for serum samples and 0.1 μg/g for bone tissue samples. The coefficients of variation for the assays are 4.48 and 8.41% at the limit of quantification for serum and bone tissue samples, respectively. Bone tissue samples as small as 50 mg can be used.  相似文献   

11.
Quantitative analysis of therapeutic compounds and their metabolites in biological matrix (such as plasma, serum or urine) nowadays requires sensitive and selective methods to allow the determination of concentrations in the ng/ml range. A new on-line LC–MS–MS method using atmospheric pressure chemical ionisation (APCI) as interface for the simultaneous determination of nifedipine (NIF) and its metabolite in human plasma, dehydronifedipine (DNIF) has been developed. The compounds were extracted from plasma using solid-phase extraction (SPE) on disposable extraction cartridges (DECs). The SPE operations were performed automatically by means of a sample processor equipped with a robotic arm (ASPEC system). The DEC filled with phenyl modified silica was first conditioned with methanol and water. The washing step was performed with water. Finally, the analytes were successively eluted with methanol and water. The liquid chromatographic (LC) separation of NIF and DNIF was achieved on a RP-18 stationary phase (4 μm). The mobile phase consisted of methanol–50 mM ammonium acetate solution (50:50, v/v). The LC was then coupled to tandem mass spectrometry with an APCI interface in the positive ion mode.

The method developed was validated. The absolute recoveries evaluated over the whole concentration range were 95±2% and 95±4% for NIF and DNIF, respectively. The method was found to be linear in the 0.5–100 ng/ml concentration range for the two analytes (r2=0.999 for both NIF and DNIF). The mean R.S.D. values for repeatability and intermediate precision were 2.9 and 3.0% for NIF and 2.2–4.7% for the metabolite.The method developed was successfully used to investigate the plasma concentration of NIF and DNIF in the pharmacokinetic studies.  相似文献   


12.
An efficient method for the determination of testosterone and pregnenolone in human nails using gas chromatography–mass spectrometry (GC–MS) with d3-testosterone as an internal standard is described. The method involves alkaline digestion and liquid–liquid extraction, with subsequent conversion to mixed pentafluoropenyldimethylsilyl-trimethylsilyl (flophemesyl-TMS) derivatives for sensitive analysis in the selected-ion monitoring (SIM) mode. The limit of detection (LOD) and limit of quantification (LOQ) were lowered to 0.1 and 0.2 pg/g, respectively, when 100 mg of nail-clippings were used. The mean recoveries of testosterone and pregnenolone were 89.8 and 86.7%, respectively, while good overall precision (% C.V.; 4.5–9.5) and accuracy (% bias; 3.9–8.4) were demonstrated. Linearity as a correlation coefficient was 0.9913 (testosterone) and 0.9965 (pregnenolone). When applied to fingernail and toenail samples from seven healthy men and nine healthy women, testosterone and pregnenolone were positively detected in the concentration range of 0.24–5.80 ng/g. The levels of two steroids studied in the nails were found to be higher in the male subjects than in the female subjects, and except for the toenails of the females, the levels of testosterone were higher than those of pregnenolone.  相似文献   

13.
A selective assay of olanzapine with liquid chromatography atmospheric pressure chemical ionization (LC–APCI–MS, positive ions) is described. The drug and internal standard (ethyl derivative of olanzapine) were isolated from serum using a solid-phase extraction procedure (C18 cartridges). The separation was performed on ODS column in acetonitrile–50 mM ammonium formate buffer, pH 3.0 (25:75). After analysis of mass spectra taken in full scan mode, a selected-ion monitoring detection (SIM) was applied with the following ions: m/z 313 and 256 for olanzapine and m/z 327 and 270 for the internal standard for quantitation. The limit of quantitation was 1 μg/l, the absolute recovery was above 80% at concentration level of 10 to 100 μg/l. The method tested linear in the range from 1 to 1000 μg/l and was applied for therapeutic monitoring of olanzapine in the serum of patients receiving (Zyprexa™) and in one case of olanzapine overdose. Olanzapine in frozen serum samples and in frozen extracts was stable over at least four weeks. The examinations of urine extracts from patients receiving olanzapine revealed peaks of postulated metabolites (glucuronide and N-desmethylolanzapine).  相似文献   

14.
A fast, reliable and sensitive liquid chromatography–mass spectrometry (LC–MS) assay for the determination of itraconazole and hydroxyitraconazole in dog plasma has been developed. The analysis involves a simple liquid–liquid extraction followed by LC–MS analysis using electrospray ionization in the positive mode. Total separation of itraconazole, hydroxyitraconazole and the internal standard, miconazole, was achieved on a C18 column in 3.5 min using an isocratic mixture of acetonitrile and 10 mM ammonium acetate. The response was linear over four-orders of magnitude, allowing reliable quantification of each species. This paper describes the development of the method and its validation.  相似文献   

15.
A sensitive and selective reversed-phase LC–ESI-MS method to quantitate perifosine in human plasma was developed and validated. Sample preparation utilized simple acetonitrile precipitation without an evaporation step. With a Develosil UG-30 column (10×4 mm I.D.), perifosine and the internal standard hexadecylphosphocholine were baseline separated at retention times of 2.2 and 1.1 min, respectively. The mobile phase consisted of eluent A, 95% 9 mM ammonium formate (pH 8) in acetonitrile–eluent B, 95% acetonitrile in 9 mM ammonium formate (pH 8) (A–B, 40:60, v/v), and the flow-rate was 0.5 ml/min. The detection utilized selected ion monitoring in the positive-mode at m/z 462.4 and 408.4 for the protonated molecular ions of perifosine and the internal standard, respectively. The lower limit of quantitation of perifosine was 4 ng/ml in human plasma, and good linearity was observed in the 4–2000 ng/ml range fitted by linear regression with 1/x weight. The total LC–MS run time was 5 min. The validated LC–MS assay was applied to measure perifosine plasma concentrations from patients enrolled on a phase I clinical trial for pharmacokinetic/pharmacodynamic analyses.  相似文献   

16.
Headspace solid-phase microextraction (HS-SPME) was utilized for the determination of three dichlorobenzene isomers (DCBs) in human blood. In the headspace at 30°C, DCBs were absorbed for 15 min by a 100-μm polydimethylsiloxane (PDMS) fiber. They were then analyzed by capillary column gas chromatography–mass spectrometry (GC–MS). By setting the initial column oven temperature at 20°C, the three isomers were resolved at the baseline level. p-Xylene-d10 was used as the internal standard (I.S.). For quantitation, the molecular ion at m/z 146 for each isomer and the molecular ion at m/z 116 for I.S. were selected. For day-to-day precision, relative standard deviations in the range 3.2–10.7% were found at blood concentrations of 1.0 and 10 μg/ml. Each compound was detectable at a level of at least 0.02 μg per 1 g of whole blood (by full mass scanning). HS-SPME–GC–MS, when performed at relatively low temperatures, was found to be feasible in toxicological laboratories. Using this method, the plasma levels of one patient who had drunk a pesticide-like material were measured.  相似文献   

17.
This paper describes a GC–MS method for the analysis of the carboxylic acid metabolite (SR26334, II) of methyl (+)-(S)--(o-chlorophenyl)-6,7-dihydrothieno[3,2-c]pyridine-5(4H)-acetate hydrogensulfate (clopidogrel, SR 25990, I) in plasma and serum. The analytical procedure involves a robotic liquid–liquid extraction with diethyl ether followed by a solid–liquid extraction on C18 cartridges. The derivatization process was performed using n-ethyl diisopropylethylamine and -bromo-2,3,4,5,6-pentafluoro toluene. A structural analogue (III) of II, was used as internal standard. The 1/X2; weighted calibration curve obtained in the range 5–250 ng/ml was well described by a quadratic equation. The extraction efficiency was better than 48% over the range studied; for the internal standard it averaged 51% at 50 ng/ml. Precision ranged from 3.6 to 15.8%, and accuracy was between 92 and 114%. Dilution has no influence on the performance of the method which could then be used to quantitate plasma samples containing up to 25 000 ng/ml. The limit of quantification was 5 ng/ml. The method validation results indicate that the performance characteristics of the method fulfilled the requirements for assay methods for use in pharmacokinetic studies.  相似文献   

18.
A highly sensitive and specific method for the determination of josamycin in human plasma by LC–MS was developed and validated. Josamycin was extracted from human plasma by a single-step liquid–liquid extraction and analyzed by LC–MS via an electrospray ionization interface. Selected ion monitoring was used to detect josamycin and its internal standard. The intra-day precision and accuracy, expressed as C.V. and R.E., ranged from 2.8% to 13.5% and −10.3% to 7.6%, respectively. The lower limit of detection was 0.1 ng/ml and the lower limit of quantitation was set at 1 ng/ml when 0.5 ml of plasma was used. No endogenous interference was observed in human plasma obtained from drug-free volunteers.  相似文献   

19.
A simple procedure based upon capillary column gas chromatography-mass spectrometry (GC—MS) is described for the detection and determination of isatin (indole-2,3-dione) in body fluids and tissues. After addition of 5-methylisatin as internal standard to urine or tissue homogenates, organic extracts are dried and derivatized successively with hydroxylamine hydrochloride and the reagent N-tert.-butyldimethylsilyl-N-methyltrifluoroacetamide (MTBSTFA). The tert.-butyldimethylsilyl derivatives obtained show good GC—MS properties and allow quantification by selected-ion monitoring of m/z 333 (isatin) and m/z 347 (internal standard). Adult and newborn human urine output values lie in the ranges 0.4–3.2 mg/mmol of creatinine (5–30 mg per 24 h) and 0.002–0.518 mg/mmol of creatinine, respectively. There is a discontinuous regional distribution in rat tissues. The GC—MS properties of a number of derivatives formed by successive reaction of isatin with hydroxylamine hydrochloride (or methoxyaminehydrochloride or ethoxyamine hydrochloride) and MTBSTFA, bis(trimethylsilyl)trifluoroacetamide, pentafluoropropionic anhydride or pentafluorobenzyl bromide are also described.  相似文献   

20.
A liquid chromatographic–tandem mass spectrometric (LC–MS–MS) method was developed for the quantitation of urinary leukotriene E4 (LTE4). LTE4 and its internal standard were extracted by solid-phase extraction and analysed using LC–MS–MS in the selected reaction monitoring (SRM) mode. A good linear response over the range of 10 pg to 10 ng was demonstrated. The accuracy of added LTE4 ranged from 97.0% to 108.0% with a mean and SD of 100.6±2.4%. We detected LTE4 (63.1±18.7 pg/mg creatinine, n=10) in healthy human urine. This method can be used to determine LTE4 in biological samples.  相似文献   