首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
A miniaturized temperature-programmed packed capillary liquid chromatographic method with on-column large volume injection and UV detection for the simultaneous determination of the three selective serotonin reuptake inhibitors citalopram, fluoxetine, paroxetine and their metabolites in plasma is presented. An established reversed-phase C8 solid-phase extraction method was employed, and the separation was carried out on a 3.5-microm Kromasil C18 0.32x300 mm column with temperature-programming from 35 (3 min) to 100 degrees C (10 min) at 1.3 degrees C/min. The mobile phase consisted of acetonitrile-45 mM ammonium formate (pH 4.00) (25:75, v/v). The non-eluting sample focusing solvent composition acetonitrile-45 mM ammonium formate (pH 4.00) (3:97, v/v) allowed injection of 10 microl or more of the plasma extracts. The method was validated for the concentration range 0.05-5.0 microM, and the calibration curves were linear with coefficients of correlation >0.993. The limits of quantification for the antidepressants and their metabolites ranged from 0.05 to 0.26 microM. The within and between assay precision of relative peak height were in the range 2-22 and 2-15% relative standard deviation, respectively. The within and between assay recoveries were in the 61-99 and 54-92% range for the antidepressants, respectively, and between 52-102 and 51-102% for the metabolites.  相似文献   

2.
A sensitive and rapid method was developed and validated for the quantitative analysis of the novel anticancer agent SZ-685C in rat plasma using high-performance liquid chromatography/tandem mass spectrometry (LC/MS/MS) in negative ion mode in order to support the following pre-clinical and clinical studies. SZ-685C and the internal standard (IS, emodin) were extracted from rat plasma by a simple liquid-liquid extraction technique using ethyl acetate as extraction solvent. Chromatographic separation was performed on an Elite Hypersil BDS C18 column (100 mm × 2.1 mm i.d., 3 μm). Elution was carried out using methanol/acetonitrile/2mM ammonium formate (pH 4) (80:15:5 (v/v/v)) at a flow-rate of 0.3 mL/min with a run time of 2.5 min. This assay was linear over a concentration range of 50-10,000 ng/mL with a lower limit of quantification of 50 ng/mL. The intra- and inter-batch precision was less than 15% for all quality control samples at concentrations of 100, 1000 and 7500 ng/mL. These results indicate that the method was efficient with a short run time and acceptable accuracy, precision and sensitivity. This method was successfully applied to explore pharmacokinetics of SZ-685C in rats after oral and intravenous administration of this agent. The absolute bioavailability is about 54.8-66.8% and the t(1/2) is 5.7-9.2h, these results provide basic information for further comprehensive pre-clinical research.  相似文献   

3.
A sensitive and rapid LC-MS/MS method was developed and validated for the determination of levamisole in human plasma. The assay was based on liquid-liquid extraction of analytes from human plasma with ethyl ether. Chromatographic separation was carried on an Agilent HC-C(8) column (150 mm × 4.6 mm, 5 μm) at 40°C, with a mobile phase consisting of acetonitrile-10 mM ammonium acetate (70:30, v/v), a flow rate of 0.5 mL/min and a total run time of 6 min. Detection and quantification were performed by mass spectrometry in the multiple reaction monitoring mode with positive electrospray ionization m/z at 205.1→178.2 for levamisole, and m/z 296.1→264.1 for mebendazole (internal standard). The assay was linear over a concentration range of 0.1-30 ng/mL with a lower limit of quantification of 0.1 ng/mL. The coefficient of variation of the assay precision was less than 8.5%. The assay was successfully used to analyze human plasma samples in a pharmacokinetic study where levamisole was administered as a liniment.  相似文献   

4.
An HPLC-MS/MS method was developed for the determination of MK-0518 (raltegravir), an HIV integrase inhibitor, in human plasma over the concentration range of 2-1000 ng/mL. Stable isotope labeled (13)C(6)-MK-0518 was used as an internal standard. The sample preparation procedure utilized liquid-liquid extraction with hexane:methylene chloride in the 96-well format with a 200 microL plasma sample size. The compounds were chromatographed on an Ace C(18) (50 x 3.0 mm, 3 microm, titanium frits) column with 42.5/57.5 (v/v %) 0.1mM EDTA in 0.1% formic acid/methanol mobile phase at a flow rate of 0.5 mL/min. Multiple reaction monitoring of the precursor-to-product ion pairs for MK-0518 (m/z 445-->109) and (13)C(6)-MK-0518 (m/z 451-->367) on an Applied Biosystem API 4000 HPLC-MS/MS was used for quantitation. Intraday precision of standard curve concentrations in five different lots of control plasma was within 3.2%, while accuracy ranged from 94.8 to 106.8%. The mean extraction recovery of spiked plasma samples was 87%. Quality control (QC) samples were stored at -20 degrees C. Initial within day analysis showed QC accuracy within 7.5% of nominal with precision of 3.1% or less. The plasma QC samples were demonstrated to be stable for up to 23 months at -20 degrees C. The method described has been used to support over 18 clinical studies during Phase I through III of clinical development.  相似文献   

5.
An HPLC assay for plasma analysis of LY303366 (I), a semi-synthetic lipopeptide antifungal related to echinocandin B (ECB), was developed to support the selection and subsequent preclinical development of I. The method involved extraction of I from plasma with the aid of solid-phase extraction (SPE) cartidges followed by reversed-phase HPLC with UV detection at 300 nm. The method is simple, selective and is applicable to dog, rat, mouse and rabbit plasma. Validation studies using dog plasma showed that the values obtained for parameters of linearity, precision and accuracy were within acceptable limits. Based on analysis of 0.3 ml of plasma, the lower limit of quantitation was 20 ng/ml. The method has been successfully applied to determine the pharmacokinetic parameters of I in the dog following intravenous (i.v.) and oral administration. Compared to first generation ECB antifungal agents, the results of the i.v. dog study indicated a 50% reduction in clearance of the drug from plasma (0.1 l/h/kg) and an 18-fold increase in the volume of distribution at steady state (1.8 l/kg). When administered orally, compound I had an absolute bioavailability of 9%; however, plasma levels remained above the MIC for C. albicans (0.005 μg/ml) through 48 h. Given the excellent potency of I and its broad spectrum of activity relative to first generation ECB antifungal agents, the assay results for I indicate the potential for its use as a broad spectrum i.v. and oral antifungal agent.  相似文献   

6.
A simple and rapid high-performance liquid chromatographic method with fluorescence detection was developed for the determination of loratadine in small volume plasma samples. Liquid-liquid extraction of loratadine and diazepam (as internal standard) from plasma samples was performed with n-butyl alcohol/n-hexane (2:98, v/v) in alkaline condition followed by back-extraction into diluted perchloric acid. Chromatography was carried out using a C8 column (250 x 4.6 mm, 5 microm) under isocratic elution with acetonitrile-20 mM sodium dihydrogen phosphate-triethylamine (43:57:0.02, v/v), pH 2.4. Analyses were run at a flow-rate of 1.0 ml/min at room temperature. The method was specific and sensitive with a quantitation limit of 0.62 ng/ml and a detection limit of 0.2 ng/ml at a signal-to-noise ratio of 3:1. The mean absolute recovery of loratadine from plasma was 84%, while the intra-and inter-day coefficient of variation and percent error values of the assay method were all less than 9.7%. Linearity was assessed in the range of 0.62-20 ng/ml in plasma with a correlation coefficient of greater than 0.999. The method has been used to analyze several hundred human plasma samples for bioavailability studies.  相似文献   

7.
A specific, accurate, precise and reproducible assay for the quantitation of a novel indolylpiperazine anti-migraine agent (I) in plasma from various animal species is described. The method involves addition of internal standard (I.S.) and 1.0 M sodium carbonate to the plasma sample, vortex-mixing and extraction with ethylene dichloride. The organic layer is then back-extracted in a buffer consisting of 0.1 M tetramethylammonium hydroxide (TMAH), pH 3.0 and 0.1 M (NH4)2HPO4, pH 3.0, in water. The aqueous layer is injected on to a Zorbax cyano analytical column with a mobile phase consisting of acetonitrile, methanol and water (15:5:80, v/v/v) with 0.01 M TMAH, pH 3.0 and 0.01 M (NH4)2HPO4, pH 3.0. The eluate is monitored by electrochemical detection at 0.9 V (guard cell), 0.5 V (detector 1) and 0.8 V (detector 2). The retention times of I and I.S. were 7 and 10 min, respectively. In drug-free control plasma, there were no interfering peaks seen at the retention times of I or I.S. The standard curve was linear over the concentration range of 5–500 ng/ml in rat, monkey, mouse and rabbit plasma. The lower limit of quantitation in all four matrices was 5.0 ng/ml. Within- and between-assay variability of quality control samples was less than 9% relative standard deviation and the predicted concentration of the quality control samples deviated by less than 15% from the nominal concentration. The stability of I was established for up to 36 h in the autosampler tray, up to 10 months in plasma at −20°C and up to 2 h in plasma at room temperature. The assay is validated for determination of I in plasma.  相似文献   

8.
A sensitive and specific high performance liquid chromatography-electrospray ionization-tandem mass spectrometry (HPLC-ESI-MS/MS) method has been developed and validated for the determination of isoforskolin in canine plasma. Liquid-liquid extraction was used to extract isoforskolin and the internal standard (I.S.) eplerenone from canine plasma. The chromatographic separation was performed on an Agela Venusil XBP Phenyl column with an isocratic mobile phase consisting of methanol-2mM ammonium acetate-formic acid (62:38:0.1, v/v/v), pumped at 0.35 mL/min. Isoforskolin and I.S. were detected at m/z 433.4→373.3 and m/z 415.3→163.5 in positive ion and multiple reaction monitoring (MRM) mode, respectively. The standard curves were linear over the concentration range of 0.1-200 ng/mL (r>0.99). The intra- and inter-batch accuracy values for isoforskolin at four concentrations were 90.2-108.3% and 97.8-106.6%, respectively. The RSDs were less than 6.0%. The mean extraction recoveries of isoforskolin and I.S. were 97.0 and 88.4%, respectively. The method was successfully applied to the pharmacokinetic study after an intravenous administration of isoforskolin in beagle dogs.  相似文献   

9.
A rapid, selective and sensitive high-performance liquid chromatographic method with spectrophotometric detection was developed for the determination of clarithromycin in human plasma. Liquid-liquid extraction of clarithromycin and norverapamil (as internal standard) from plasma samples was performed with n-hexane/1-butanol (98:2, v/v) in alkaline condition followed by back-extraction into diluted acetic acid. Chromatography was carried out using a CN column (250 mm x 4.6 mm, 5 microm) under isocratic elution with acetonitrile-50 mM aqueous sodium dihydrogen phosphate (32:68, v/v), pH 4.5. Detection was made at 205 nm and analyses were run at a flow-rate of 1.0 ml/min at 40 degrees C. The analysis time was less than 11 min. The method was specific and sensitive with a quantification limit of 31.25 ng/ml and a detection limit of 10 ng/ml in plasma. The mean absolute recovery of clarithromycin from plasma was 95.9%, while the intra- and inter-day coefficient of variation and percent error values of the assay method were all less than 9.5%. Linearity was assessed in the range of 31.25-2000 ng/ml in plasma with a correlation coefficient of greater than 0.999. The method was used to analyze several hundred human plasma samples for bioavailability studies.  相似文献   

10.
Achiral and chiral HPLC methods were developed for clinafloxacin, a quinolone antimicrobial agent. For achiral assay, analytes were isolated from plasma by precipitating plasma proteins. Separation was achieved on a C18 column using an isocratic eluent of ion pairing solution–acetonitrile (80:20, v/v) at 1.0 ml/min with UV detection at 340 nm. The ion pairing solution was 0.05 M citric acid, 1.15 mM tetrabutylammonium hydroxide and 0.1% ammonium perchlorate. Inter-assay accuracy was within 4.9% with an inter-assay precision of 3.7% over a quantitation range of 0.025 to 10.0 μg/ml. For chiral assay, analytes were isolated from plasma by solid-phase extraction. Separation was achieved on a Crownpak CR(+) column using an isocratic eluent of water–methanol (88:12, v/v) containing 0.1 mM decylamine at 1.0 ml/min with UV detection at 340 nm. Perchloric acid was added to adjust pH to 2. Inter-assay accuracy was within 3.5% with a inter-assay precision of 5.4% over a quantitation range of 0.040 to 2.5 μg/ml.  相似文献   

11.
To support pharmacokinetic studies, a selective and sensitive liquid chromatography/tandem mass spectrometry (LC-MS/MS) method has been developed and validated for the simultaneous determination of a novel KDR kinase inhibitor (1) and its active metabolite (2) in human plasma. The method is fully automated using a Packard MultiPROBE II system and a TomTec Quadra 96 liquid handling workstation to perform sample preparation and solid-phase extraction (SPE). Following the extraction on a mixed-mode SPE using Oasis MCX 96-well plate, the analytes were separated on a Aquasil C18 column (50 mm x 2.1 mm, i.d., 3 microm) with a mobile phase consisting of acetonitrile/ammonium acetate buffer (5 mM, pH 5.0) (60/40, v/v). The run time for each injection was 4.5 min with the retention times of approximately 2.0 and 2.7 min for 1 and 2 respectively, at a flow rate of 0.25 mL/min. A tandem mass spectrometric detection was conducted using multiple reaction monitoring (MRM) under the positive ion mode with a turbo ion-spray interface. The linear ranges of the calibration curves were 0.05-400 ng/mL for 1 and 0.1-400 ng/mL for 2 on a PE Sciex API 4000 LC-MS/MS system. The lower limits of quantitation (LLOQ) of the assay were 0.05 and 0.1 ng/mL for 1 and 2 respectively, when 0.4 mL of plasma was processed. Intra-day assay precision (using five standard curves prepared by spiking compounds to five lots of plasma) was less than 4.9% for 1 and less than 9.6% for 2 on each concentration. Assay accuracy was found to be 95.1-104.6% of nominal for 1 standards and 93.5-105.6% for 2 standards. QC samples were stable when kept at room temperature for 4 h, at -70 degrees C for 10 days, and after three freeze-thaw cycles. The extraction recoveries were 80%, 83% and 84% for 1 and 2 and I.S. respectively, and no significant matrix effects were observed. The method was successfully applied to plasma samples from clinical studies after oral administration of compound 1.  相似文献   

12.
A high-performance liquid chromatography method with diode array detection (HPLC-DAD) was developed for quantification of aripiprazole and dehydro-aripiprazole, in human plasma. After a simple liquid-liquid extraction, chromatographic separation was carried out on a C18 reversed-phase column, using an ammonium buffer-acetonitrile mobile phase (40:60, v/v). The total run time was only 7 min at a flow-rate of 1.0 ml/min. The precision values were less than 12% and the accuracy values were ranging from 98 to 113% and the lower limit of quantification was 2 ng/ml for both compounds. Calibration curves were linear over a range of 2-1000 ng/ml. The mean trough plasma concentrations in patients treated with aripiprazole were 157 and 29 ng/ml for aripiprazole and dehydro-aripiprazole, respectively.  相似文献   

13.
A selective and sensitive high-performance liquid chromatography method has been developed and validated for determination of mitiglinide (MGN) in rat plasma using 2-(4-biphenylyl) propionic acid (BPA) as internal standard. Liquid-liquid extraction was used for sample preparation. Chromatographic separation was achieved on a C(18) column using acetonitrile and 0.02 mol/l KH(2)PO(4) buffer (pH 4.0) (45:55, v/v) as mobile phase delivered at 1.0 ml/min. The UV detector was set at 210 nm. The assay was linear over the range 0.1-20 microg/ml for MGN. The average extraction recoveries of MGN and BPA from rat plasma were 98.6 and 97.4%, respectively. The developed method has been applied to the pharmacokinetic study of MGN in rats.  相似文献   

14.
A rapid, selective, sensitive and reproducible HPLC with recutive electrochemical detection for quantitatvie determination of artemether (ART) and its plasma metabolite, dihydroartemisinin (DHA: and β isomers) in plasma is described. The procedure involved the extraction of ART, DHA and the internal standard, artemisinin (ARN) with dichloromethane-tert.-methylbutyl ether (1:1, v/v) or n-butyl chloride-ethyl acetate (9:1, v/v). Chromatographic separation was performed with a mobile phase of acetonitrile-water (20:80, v/v) containing 0.1 M acetic acid pH 5.0, running through a μBondapak CN column. The method was capable of separating the two isomeric forms of DHA (, β). The retention times of -DHA, β-DHA, ARN and ART were 4.6, 5.9, 7.9 and 9.6 min, respectively. Validation of the assay method was performed using both extraction systems. The two extraction systems produced comparable recoveries of the various analytes. The average recoveries of ART, DHA and ARN over the concentration range 80–640 ng/ml were 86–93%. The coefficients of variation were below 10% for all three drugs (ART, -DHA, ARN). The minimum detectable concentrations for ART and -DHA in spiked plasma samples were 5 and 3 ng/ml, respectively. The method was found to be suitable for use in clinical pharmacokinetic study.  相似文献   

15.
A selective and sensitive high-performance liquid chromatographic assay for a novel cognitive enhancer, X9121 (I), and its mono N-oxide metabolite, XG696 (II), in dog plasma has been developed. Compounds I, II and internal standard (I.S.) were first extracted from dog plasma using a solid-phase Bond Elut Certify I 10-ml LRC reservoir extraction cartridge. Chromatographic separation of I, II and I.S. was conducted on a reversed-phase Zorbax Stable Bond cyano column. Ammonium acetate buffer (0.05 M, pH 6)-acetonitrile-triethylamine (75:25:0.1, v/v) was used as the mobile phase. Detection of all three compounds was by UV light absorbance at 313 nm. Using 0.5 ml of dog plasma for extraction, the minimum quantifiable limit was 10 ng/ml and the assay was linear from 10 to 5400 ng/ml. The coefficients of variation for intra-day precision ranged from 2.2 to 8.5% for I and from 2.5 to 9.8% for II. The coefficients of variation for the inter-day precision for these two compounds ranged from 2.6 to 9.0% and from 3.6 to 16.2%, respectively. The absolute percent differences for the accuracy results were within 11.0% of the spiked concentrations. Compounds I and II were stable in frozen plasma at −20°C for at least 67 days.  相似文献   

16.
A sensitive, specific and fast high-performance liquid chromatography/tandem mass spectrometry (HPLC-MS/MS) assay for the determination of vinorelbine in mouse and human plasma is presented. A 200 microL aliquot was extracted with solid-phase extraction (SPE) using Bond-Elut C(2) cartridges. Dried extracts were reconstituted in 100 microL 1 mM ammonium acetate pH 10.5-acetonitrile-methanol (21:9:70, v/v/v) containing the internal standard vintriptol (100 ng/mL) and 10 microL volumes were injected onto the HPLC system. Separation was achieved on a 50 mm x 2.0 mm i.d. Gemini C(18) column using isocratic elution with 1 mM ammonium acetate pH 10.5-acetonitrile-methanol (21:9:70, v/v/v) at a flow rate of 0.4 mL/min. HPLC run time was only 5 min. Detection was performed using positive ion electrospray ionization followed by tandem mass spectrometry (ESI-MS/MS). The assay quantifies vinorelbine from 0.1 to 100 ng/mL using human plasma sample volumes of 200 microL. With this method vinorelbine can be measured in mouse plasma samples when these samples are diluted eight times in control human plasma. Calibration samples prepared in control human plasma can be used for the quantification of the drug. The lower limit of quantification in mouse plasma is 0.8 ng/mL. This assay is used to support preclinical and clinical pharmacologic studies with vinorelbine.  相似文献   

17.
A method for the simultaneous determination of R- and S-propranolol and R- and S-hyoscyamine in human plasma was developed, validated and applied to the analysis of samples from a clinical study. Sample preparation was performed by solid-phase extraction of 2 ml of human plasma using Oasis MCX cartridges and the enantioselective separations were achieved using a Chirobiotic V chiral stationary phase. The chromatography was carried out using gradient elution with a mobile phase composed of methanol:acetic acid:triethylamine which was varied from 100:0.05:0.04 to 100:0.05:0.1 (v/v/v) over 30 min and delivered at a flow rate 1 ml/min. The internal standard was R,S-propranolol-d7 and the analytes were quantified using a single quadrupole mass spectrometer employing APCI interface operated in the positive ion mode with single ion monitoring. The enantioselective separation factors, alpha, were 1.15 and 1.07 for S- and R-propranolol and R- and S-hyoscyamine, respectively. The standard curves were linear for all target compounds with coefficients of determination (r2) ranging from 0.9977 to 0.9999. The intra- and inter-day precision and accuracy were 相似文献   

18.
A high-performance liquid chromatographic (HPLC) method was developed using solid-phase extraction, o-phthalaldehyde (OPA) derivatization and fluorescence detection for the determination of the direct thrombin inhibitor bivalirudin in human plasma and urine. The use of this assay will facilitate the study of the pharmacodynamics of bivalirudin in studies of special patient populations. A C(18) bioanalytical column at a flow rate of 1 ml/min with an aqueous trifluoroacetic acid (0.1% TFA in deionized water, pH 2.2, v/v) mobile phase and methanol gradient was used. The assay demonstrated linearity from 3 to 20 microg/ml bivalirudin in plasma, with a detection limit of 1 microg/ml. The method was utilized in a study evaluating the pharmacokinetic and pharmacodynamic effects of bivalirudin in patients undergoing percutaneous coronary interventions (PCIs).  相似文献   

19.
A high-performance liquid chromatographic–electrochemical assay was developed and validated for the quantitation of BMS-181885 (I), an anti-migraine agent, in monkey plasma. The assay involved a solid-phase extraction of I and BMY-46317 (internal standard; I.S.) on a 1-ml cyano cartridge using the automatic solid-phase extraction cartridge (ASPEC) system. Immediately following the conditioning of the cyano column (3 ml of methanol and 2 ml of 1% glacial acetic acid), plasma (0.25 ml) was loaded on to the column. The column was then washed with a 3 ml of 0.1 M ammonium acetate buffer (pH 6). The final elution of the analytes was performed using 2 ml of methanol. The eluate was then evaporated to dryness (gentle stream of nitrogen at 40°C) and the residue was dissolved in the mobile phase and injected on to a YMC basic column (15 cm×4.6 mm; 5 μm particle size) at a flow-rate of 1 ml/min. A mixture of 0.1 M ammonium acetate at pH 6–acetonitrile–methanol (70:20:10, v/v) was used as the mobile phase. Standard curves, with a lower limit of quantitation of 2 ng/ml of I were linear (r2≥0.998; range: 2–50 ng/ml). Based on the analysis of the quality control (QC) samples, the assay was both accurate and precise. The stability of I was established following freeze–thaw cycles and storage at or below −20°C. The extraction recovery of I from monkey plasma was about 82%. The validated assay method was applied to determine the pharmacokinetics of I in monkeys following a single 1 mg/kg intravenous dose.  相似文献   

20.
A highly sensitive and simple high-performance liquid chromatographic (HPLC) assay has been developed and validated for the quantification of dibenzoylmethane (DBM) in rat plasma. DBM and internal standard (I.S.) 1-(5-chloro-2-hydroxy-4-methylphenyl)-3-phenyl-1,3-propanedione (CHMPP) were extracted from rat plasma by ethyl acetate/methanol (95:5, v/v) and analyzed using reverse-phase gradient elution with a Phenomenex Gemini C18 5-mum column. A gradient of mobile phase (mobile phase A: water/methanol (80:20, v/v) with 0.1% TFA and mobile phase B: acetonitrile with 0.1% TFA) at a flow rate of 0.2 mL/min, and ultraviolet (UV) detection at 335 nm were utilized. The lower limit of quantification (LLOQ) using 50 microL rat plasma was 0.05 microg/mL. The calibration curve was linear over a concentration range of 0.05-20 microg/mL. The mean recoveries were 80.6+/-5.7, 83.4+/-1.6 and 77.1+/-3.4% with quality control (QC) level of 0.05, 1 and 20 microg/mL, respectively. Intra- and inter-day assay accuracy and precision fulfilled US FDA guidance for industry bioanalytical method validation. Stability studies showed that DBM was stable in rat plasma after 4h incubation at room temperature, one month storage at -80 degrees C and three freeze/thaw cycles, as well as in reconstitute buffer for 48 h at 4 degrees C. The utility of the assay was confirmed by the successful analysis of plasma samples from DBM pharmacokinetics studies in the rats after oral and intravenous administrations.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号