The purposes of this study were twofold: (a) to examine the test-retest reproducibility and concurrent validity of the horizontal hip joint angle test (H-HJA) and vertical hip joint angle test (V-HJA) for estimating hamstring flexibility measured with an inclinometer during the passive straight-leg raise test (PSLR) and (b) to determine whether the H-HJA cutoff scores may be used for V-HJA for the detection of short hamstring flexibility in active recreationally young adults. Fifty young men underwent the H-HJA, V-HJA, and PSLR on the right and left legs 3 times in a randomized order with a 4-week interval between trials under a controlled laboratory environment. Reproducibility was examined using coefficient of variation (CV) and intraclass correlation coefficient (ICC3,1) and their respective confidence limits. Regression and kappa correlation analyses were performed to examine the association of H-HJA and V-HJA with the PSLR test, and the 95% limits of agreement between H-HJA and V-HJA were calculated to check if there were differences in the raising scores. The results demonstrated acceptable reproducibility measures for the H-HJA (4.12% CV; 0.93 ICC), V-HJA (4.99% CV; 0.92 ICC), and PSLR (4.83% CV; 0.88 ICC). The H-HJA (R = 0.62) and V-HJA (R = 0.63) results were significantly associated with those of the PSLR. The 95% limits of agreement between the H-HJA and V-HJA reported systematic bias (+7.12 cm) and a wide 95% random error ( ±13.72 cm). This study concluded that the test-retest reproducibility of the H-HJA, V-HJA, and PSLR is acceptable and that the validity of H-HJA and V-HJA is moderate. Furthermore, the H-HJA cutoff scores should not be used for V-HJA for the detection of short hamstring muscles in young adults.  相似文献   

2.

Purpose

To evaluate the intrasession reproducibility of various thickness parameters used to diagnose and follow-up glaucoma, in particular circumpapillary total retinal thickness (cpTR) provided by the RS-3000 optical coherence tomograph (OCT).

Methods

Fifty-three healthy eyes of 28 subjects underwent three consecutive imaging with the RS-3000 Advance OCT (NIDEK, Aichi,Japan) to evaluate the intrasession reproducibility of circumpapillary total retinal thickness (cpTR), circumpapillary retinal nerve fiber layer thickness (cpRNFL), macular ganglion cell complex thickness (mGCC) and macular total retina thickness (mTR) measurements. Intraclass correlation (ICC), coefficient of variation (CV) and reproducibility coefficient (RC) were calculated for each parameter.

Results

The ICC and CV values for mean cpTR and cpRNFL were 0.987 and 0.897, and 0.60% and 2.81%, respectively. The RC values for the mean cpTR and cpRNFL were 5.95 μm and 9.04 μm, respectively. For all cpTR parameters the ICC values were higher and both the CV and RC values were lower than those for the corresponding cpRNFL parameters. The ICC and CV values for superior mGCC, inferior mGCC, superior mTR and inferior mTR were 0.983, 0.980, 0.983 and 0.988, and 0.84%, 0.98%, 0.48% and 0.43%, respectively. The RC values for superior mGCC, inferior mGCC, superior mTR and inferior mTR were 2.86 μm, 3.12 μm, 4.41μm and 4.43 μm, respectively.

Conclusions

Intrasession reproducibility of cpTR, mGCC and mTR measurements made on healthy eyes was high. Repeatability of cpTR measurements was better than that of the corresponding cpRNFL measurements. These results suggest that future clinical investigations addressing detection of glaucoma and glaucomatous progression with the RS-3000 OCT may benefit from focusing on the cpTR parameters.  相似文献   

3.

Introduction

The reproducibility of tractography is important to determine its sensitivity to pathological abnormalities. The reproducibility of tract morphology has not yet been systematically studied and the recently developed tractography contrast Tract Density Imaging (TDI) has not yet been assessed at the tract specific level.

Materials and Methods

Diffusion tensor imaging (DTI) and probabilistic constrained spherical deconvolution (CSD) tractography are performed twice in 9 healthy subjects. Tractography is based on common space seed and target regions and performed for several major white matter tracts. Tractograms are converted to tract segmentations and inter-session reproducibility of tract morphology is assessed using Dice similarity coefficient (DSC). The coefficient of variation (COV) and intraclass correlation coefficient (ICC) are calculated of the following tract metrics: fractional anisotropy (FA), apparent diffusion coefficient (ADC), volume, and TDI. Analyses are performed both for proximal (deep white matter) and extended (including subcortical white matter) tract segmentations.

Results

Proximal DSC values were 0.70–0.92. DSC values were 5–10% lower in extended compared to proximal segmentations. COV/ICC values of FA, ADC, volume and TDI were 1–4%/0.65–0.94, 2–4%/0.62–0.94, 3–22%/0.53–0.96 and 8–31%/0.48–0.70, respectively, with the lower COV and higher ICC values found in the proximal segmentations.

Conclusion

For all investigated metrics, reproducibility depended on the segmented tract. FA and ADC had relatively low COV and relatively high ICC, indicating clinical potential. Volume had higher COV but its moderate to high ICC values in most tracts still suggest subject-differentiating power. Tract TDI had high COV and relatively low ICC, which reflects unfavorable reproducibility.  相似文献   

4.

Purpose

To compare the reproducibilities of manual and semiautomatic segmentation method for the measurement of normalized cerebral blood volume (nCBV) using dynamic susceptibility contrast-enhanced (DSC) perfusion MR imaging in glioblastomas.

Materials and Methods

Twenty-two patients (11 male, 11 female; 27 tumors) with histologically confirmed glioblastoma (WHO grade IV) were examined with conventional MR imaging and DSC imaging at 3T before surgery or biopsy. Then nCBV (means and standard deviations) in each mass was measured using two DSC MR perfusion analysis methods including manual and semiautomatic segmentation method, in which contrast-enhanced (CE)-T1WI and T2WI were used as structural imaging. Intraobserver and interobserver reproducibility were assessed according to each perfusion analysis method or each structural imaging. Interclass correlation coefficient (ICC), Bland-Altman plot, and coefficient of variation (CV) were used to evaluate reproducibility.

Results

Intraobserver reproducibilities on CE-T1WI and T2WI were ICC of 0.74–0.89 and CV of 20.39–36.83% in manual segmentation method, and ICC of 0.95–0.99 and CV of 8.53–16.19% in semiautomatic segmentation method, repectively. Interobserver reproducibilites on CE-T1WI and T2WI were ICC of 0.86–0.94 and CV of 19.67–35.15% in manual segmentation method, and ICC of 0.74–1.0 and CV of 5.48–49.38% in semiautomatic segmentation method, respectively. Bland-Altman plots showed a good correlation with ICC or CV in each method. The semiautomatic segmentation method showed higher intraobserver and interobserver reproducibilities at CE-T1WI-based study than other methods.

Conclusion

The best reproducibility was found using the semiautomatic segmentation method based on CE-T1WI for structural imaging in the measurement of the nCBV of glioblastomas.  相似文献   

5.
This study was designed to determine trial-to-trial and day-to-day reproducibility of isometric force and electromyogram activity (EMG) of the knee extensor muscles in water and on dry land as well as to make comparisons between the two training conditions in muscle activity and force production. A group of 20 healthy subjects (12 women and 8 men) were tested three times over 2 weeks. A measurement session consisted of recordings of maximal and submaximal isometric knee extension force with simultaneous recording of surface EMG from the vastus medialis, vastus lateralis and biceps femoris muscles. To ensure identical measurement conditions the same patient elevator chair was used in both the dry and the wet environment. Intraclass correlation coefficients (ICC) and coefficients of variation (CV) showed high trial-to-trial (ICC = 0.95-0.99, CV = 3.5%-11%) and day-to-day reproducibility (ICC=0.85-0.98, CV=11%-19%) for underwater and dry land measurements of force and EMG in each muscle during maximal contractions. The day-to-day reproducibility for submaximal contractions was similar. The interesting finding was that underwater EMG amplitude decreased significantly in each muscle during maximal (P < 0.01-P < 0.001) and submaximal contractions (P < 0.05-P < 0.001). However, the isometric force measurements showed similar values in both wet and dry conditions. The water had no disturbing effect on the electrodes as shown by slightly lowered interelectrode resistance values, the absence of artefacts and low noise levels of the EMG signals. It was concluded that underwater force and EMG measurements are highly reproducible. The significant decrease of underwater EMG could have electromechanical and/or neurophysiological explanations.  相似文献   

6.
The aims of this study were to evaluate the time-course of the familiarization process associated with a test of multiple sprint running performance and to determine the reliability of various performance indices once familiarization had been established. Eleven physically active men (mean age: 21 +/- 2 years) completed 4 multiple sprint running trials (12 x 30 m; repeated at 35-s intervals) with 7 days between trials. All testing was conducted indoors, and times were recorded by twin-beam photocells. Results revealed no apparent learning effects as evidenced by no significant (p > 0.05) between-trial differences in measures of fastest or mean 30-m sprint time. Within-subject test-retest reliability determined over 4 trials by coefficient of variation (CV) and intraclass correlation coefficient (ICC) showed excellent reliability for measures of fastest and mean sprint times (CV range: 1.34-2.24%; ICC range: 0.79-0.94). Pre- and posttrial blood lactate concentrations showed good reliability when judged in context with typical values (CV range: 12.08-18.21%; ICC range: 0.72-0.78). In contrast, and in line with previous research, fatigue data showed much greater variability (CV: 26.43%; ICC: 0.66). The results of this study suggest that high degrees of test-retest reliability can be obtained in many multiple sprint running indices without the need for prior familiarization.  相似文献   

7.
This study aimed to compare the reliability and magnitude of conditioned pain modulation (CPM) by applying different test stimuli (TS) and conditioning stimuli (CS). Twenty-six healthy male participants were recruited in the study of two identical sessions. In each session, four TS (electrical, heat, handheld, and cuff pressure algometry) were applied before and during CS (cold pressor test (CPT) or cuff algometry). The same procedure was repeated with 45-min intervals, but with the other CS. Five thresholds were measured including four pain detection thresholds from four TS and pain tolerance threshold from cuff TS (cuff PTT). Intraclass correlation coefficient (ICC (3,1)) and coefficient of variation (CV) were calculated as measures of reliability. The reliability of TS before and during CS was good for all combinations (ICC: 0.60–0.96, CV: 2.2–22.9%), but the reliability of the CPM effect varied (ICC: 0.04–0.53, CV: 63.6–503.9%). The most reliable combinations were considered to be the handheld pressure pain threshold with CPT (ICC: 0.49, CV: 63.6%) and the cuff pressure pain threshold with CPT (ICC: 0.44, CV: 107.6%). Significant CPM effects were found for all combinations, except the combinations of electrical and heat pain thresholds with cuff CS, which indicates the novel classification of the CPM mechanism. The combinations of handheld pressure and heat pain threshold with CPT would provide the minimum sample size to detect the significant CPM changes in further studies. It is beneficial to provide and compare both ICC and CV to design further clinical trials.  相似文献   

8.
In cohort studies, longitudinal changes in individuals are often studied. The sample size requirements are then directly related to the responsiveness of the measuring instrument/scale, which is defined as the ability to detect a clinically meaningful change over time. We demonstrate that whatever the index used to assess responsiveness (effect size, standardized response mean, Guyatt's index), it is enhanced by an increase in the intraclass correlation coefficient (ICC), which assesses the reproducibility of the measuring instrument/scale. Therefore, an improvement in reproducibility leads to an increase in responsiveness and thus an increase in power. In the special case of one observation per subject and time, we also prove that an increase in the ICC reduces the coefficient of variation of the estimators of the standardized response mean and of Guyatt's index. This result has also been observed for the effect size on an example. Such a result implies that the better the reproducibility, the lower the sample size requirements for confident statistical inference of responsiveness results.  相似文献   

9.
The purpose of this study was to establish the reproducibility of a series of anthropometric measures performed twice during one week during a three year period in boys and girls. The subjects of this investigation were 39 children (21 boys and 18 girls), 9-10 year of age at the beginning of the study. Children were measured three times with one year interval. Children were classified by Tanner stage 1-2 during the first measurements, stage 1-3 during the second measurements and stage 1-4 during the third measurements. Body height and weight were measured and BMI calculated. All anthropometric parameters were measured according to the protocol recommended by the International Society for the Advancement of Kinanthropometry (Norton & Olds 1996). Nine skinfolds, 13 girths, eight lengths and eight breadths/lengths were measured. The reproducibility of body height (r = 0.995-0.999), body weight (r = 0.990-0.999) and BMI (r = 0.969-0.999) was very high in boys and girls. The intraclass correlations (ICC), technical errors (TE) and coefficients of variation (CV) were quite different depending on the measurement site of the skinfold thickness. It was surprising that the ICCs were highest and TEs and CVs were lowest during the second year of the measurement. The computed ICC was high, and TE and CV values were quite similar and relatively low in girth, length and breadth/length measurements. It was concluded that the reproducibility of girths, lengths and breadths/lengths in children is very high and the reproducibility of skinfolds is high. Specifically, the reproducibility is very high immediately before puberty in boys and girls.  相似文献   

10.
IntroductionThe purpose of this study was to examine the relative and absolute between-day reliability of the motor unit number index (MUNIX).MethodsYoung, healthy adults (n = 19) attended two testing sessions separated by 4-weeks where their maximal pinch-grip strength, MUNIX, and motor unit size index (MUSIX) were assessed in the abductor pollicis brevis muscle. Reliability was assessed by intraclass correlation coefficients (ICC), coefficient of variation (CV) and limits of agreement (LOA).ResultsNo mean differences were observed for MUNIX or MUSIX. The CV for the MUNIX and MUSIX measures were between 13.5% and 17.5%. The ICC for both measures were moderate to moderately-high (0.73–0.76), The LOA for both indicated a homoscedastic relationship.DiscussionOur findings indicate moderate to moderately-high reliability for both MUNIX and MUSIX. Future work is needed to ensure both measures are reliable in other muscles and cohorts, and further investigations are required to examine the validity of MUNIX.  相似文献   

11.
Tensiomyography is a method for valid and non-invasive estimation of skeletal muscle fibre type composition. The validity of selected temporal tensiomyographic measures has been well established recently; there is, however, no evidence regarding the method's between-day reliability. Therefore it is the aim of this paper to establish the between-day repeatability of tensiomyographic measures in three skeletal muscles. For three consecutive days, 10 healthy male volunteers (mean±SD: age 24.6 ± 3.0 years; height 177.9 ± 3.9 cm; weight 72.4 ± 5.2 kg) were examined in a supine position. Four temporal measures (delay, contraction, sustain, and half-relaxation time) and maximal amplitude were extracted from the displacement-time tensiomyogram. A reliability analysis was performed with calculations of bias, random error, coefficient of variation (CV), standard error of measurement, and intra-class correlation coefficient (ICC) with a 95% confidence interval. An analysis of ICC demonstrated excellent agreement (ICC were over 0.94 in 14 out of 15 tested parameters). However, lower CV was observed in half-relaxation time, presumably because of the specifics of the parameter definition itself. These data indicate that for the three muscles tested, tensiomyographic measurements were reproducible across consecutive test days. Furthermore, we indicated the most possible origin of the lowest reliability detected in half-relaxation time.  相似文献   

12.
The purpose of this study was to comprehensively evaluate the reliability of a large number of commonly utilized experimental tests of in vivo human neuromuscular function separated by 4-weeks. Numerous electrophysiological parameters (i.e., voluntary and evoked electromyogram [EMG] signals), contractile properties (i.e., evoked forces and rates of force development and relaxation), muscle morphology (i.e., MRI-derived cross-sectional area [CSA]) and performance tasks (i.e., steadiness and time to task failure) were assessed from the plantarflexor muscle group in 17 subjects before and following 4-weeks where they maintained their normal lifestyle. The reliability of the measured variables had wide-ranging levels of consistency, with coefficient of variations (CV) ranging from approximately 2% to 20%, and intraclass correlation coefficients (ICC) between 0.53 and 0.99. Overall, we observed moderate to high-levels of reliability in the vast majority of the variables we assessed (24 out of the 29 had ICC>0.70 and CV<15%). The variables demonstrating the highest reliability were: CSA (ICC=0.93-0.98), strength (ICC=0.97), an index of nerve conduction velocity (ICC=0.95), and H-reflex amplitude (ICC=0.93). Conversely, the variables demonstrating the lowest reliability were: the amplitude of voluntary EMG signal (ICC=0.53-0.88), and the time to task failure of a sustained submaximal contraction (ICC=0.64). Additionally, relatively little systematic bias (calculated through the limits of agreement) was observed in these measures over the repeat sessions. In conclusion, while the reliability differed between the various measures, in general it was rather high even when the testing sessions are separated by a relatively long duration of time.  相似文献   

13.
Passive muscle stretching can be used in vivo to assess the viscoelastic properties of the entire musculo-articular complex, but does not allow the specific determination of the muscle or tendon viscoelasticity. In this respect, the local muscle hardness (LMH) of the gastrocnemius medialis (GM) belly was measured during a passive ankle stretching of 10 subjects using transient elastography. A Biodex isokinetic dynamometer was used to stretch ankle plantar flexors, to measure ankle angle, and the passive torque developed by the ankle joint in resistance to the stretch. Results show that the LMH increased during the stretching protocol, with an averaged ratio between maximal LMH and minimal LMH of 2.62+/-0.46. Furthermore, LMH-passive torque relationships were nicely fitted using a linear model with mean correlation coefficients (R(2)) of 0.828+/-0.099. A good reproducibility was found for the maximal passive torque (ICC=0.976, SEM=2.9Nm, CV=5.5%) and the y-intercept of the LMH-passive torque relationship (ICC=0.893, SEM=105Pa, CV=7.8%). However, the reproducibility was low for the slope of this relationship (ICC=0.631, SEM=10.35m(-2), CV=60.4%). The y-intercept of the LMH-passive torque relationship was not significantly changed after 10min of static stretching. This result confirms the finding of a previous study indicating that changes in passive torque following static stretching could be explained by an acute increase in muscle length without any changes in musculo-articular intrinsic mechanical properties.  相似文献   

14.

Background

Serum measurements of cytokines, mediators of various B and T cell activities, are important markers of inflammation and immune dysregulation. We assessed the reproducibility of serum cytokine measurements over a five-year period among participants in the Prostate, Lung, Colorectal, and Ovarian Cancer Screening Trial (PLCO).

Methods

Levels of 13 cytokines [interleukin (IL) 1β, IL-2, IL-4, IL-5, IL-6, IL-7, IL-8, IL-10, IL-12p70, IL-13, interferon-gamma (IFNγ), granulocyte macrophage colony-stimulating factor (GM-CSF), and tumor necrosis factor-α (TNFα)] in stored sera from three collections (study baseline,+1 year, and + 5 years) among 28 randomly selected PLCO participants were measured using a high-sensitivity Luminex xMap-based multiplex panel. Within- and between-subject components of variance were estimated from random effects models and were used to calculate the coefficient of variation (CV) and intraclass correlation coefficient (ICC) for analytes with <30% of samples below the limit of detection (LOD). Spearman correlation coefficients between measurements of the same analyte over time and between analytes were also calculated.

Results

Among the six cytokines with <30% of samples below the LOD, we observed excellent reproducibility for IL-6, IL-7, IL-13, and TNFα (ICC ? 0.73), and fair to good reproducibility for IL-8 (ICC = 0.55) and IL-10 (ICC = 0.60). Spearman correlation coefficients comparing paired measurements of each cytokine at baseline and at +5 years were high (ρ ? 0.74) with the exception of IL-10 (ρ = 0.44).

Conclusions

These results suggest that measurements of most of the cytokines evaluated in this study were highly reproducible over five-year periods.  相似文献   

15.
The primary goals of this study were to adapt the Quality of Life in Epilepsy Inventory-31 items (QOLIE-31) questionnaire to the Croatian language and to assess the translated questionnaire's psychometric properties. Translation/retranslation of the English version of the QOLIE-31 was done, and all steps for cross-cultural adaptation process were performed properly by an expert committee. Later, QOLIE-31 questionnaires and previously validated Short Form-36 (SF-36) outcome instruments were given to 200 patients with epilepsy. 172 patients (86%) responded to the first set of questionnaires, and 114 of the first time respondents (66%) returned their second survey. The two measures of reliability as internal consistency and reproducibility were determined by Cronbach alpha statistics and intraclass correlation coefficient, respectively. Concurrent validity was measured by comparing with a SF-36 questionnaire, and measurement was made using the Pearson correlation coefficient (r). The study demonstrated satisfactory internal consistency with high Cronbach a values for all of the corresponding domains (seizure worry 0.84, medication effects 0.80, emotional well-being 0.73, energy/fatigue 0.76, cognitive functioning 0.71, social functioning 0.77, overall quality of life 0.65). The intraclass correlation coefficient for six domains of QOLIE-31 questionnaire demonstrated excellent test/retest reproducibility (ICC > or = 0.75), and good test/retest reproducibility (ICC 0.71) in one domain (cognitive functioning). Considering concurrent validity, three domains had excellent correlation (r = 0.75-1), while 11 had good correlation (r = 0.50 to 0.75), and 3 had moderate correlation (r = 0.25-0.50). This study demonstrated that, if measures are to be used across cultures, the items must not only be translated well linguistically but also must be culturally adapted to maintain the content validity of the instrument at a conceptual level across different cultures. Croatian version of QOLIE-31 will be a valuable contribution to outcome measurement in epilepsy patients, particularly in the context of treatment trials, but als in a wider research context.  相似文献   

16.
The best method of assessing muscular force qualities during isoinertial stretch shorten cycle lower body movements remains a subject of much debate. This study had 2 purposes: Firstly, to calculate the interday reliability of peak force (PF) measurement and a variety of force-time measures, and, secondly, to compare the reliability of the 2 most common technologies for measuring force during loaded jump squats, the linear position transducer (PT), and the force plate (FP). Twenty-five male elite level rugby union players performed 3 rebound jump squats with a 40-kg external load on 2 occasions 1 week apart. Vertical ground reaction forces (GRFs) were directly measured via an FP, and force was differentiated from position data collected using a PT. From these data, a number of force-time variables were calculated for both the FP and PT. Intraclass correlation coefficient (ICC), coefficient of variation (CV), and percent change in the mean were used as measures of between-session reliability. Additionally, Pearson's product moment correlation coefficients were used to investigate intercorrelations between variables and technologies. Both FP and PT were found to be a reliable means of measuring PF (ICC = 0.88-0.96, CV = 2.3-4.8%), and the relationship between the 2 technologies was very high and high for days 1 and 2, respectively (r = 0.67-0.88). Force-time variables calculated from FP data tended to have greater relative and absolute consistency (ICC = 0.70-0.96, CV = 5.1-51.8%) than those calculated from differentiated PT data (ICC = 0.18-0.95, CV = 7.7-93.6%). Intercorrelations between variables ranged from trivial to practically perfect (r = 0.00-1.00). It was concluded that PF can be measured reliably with both FP and PT technologies, and these measurements are related. A number of force-time values can also be reliably calculated via the use of GRF data. Although some of these force-time variables can be reliably calculated using position data, variation of measurement is generally greater when using position data to calculate force.  相似文献   

17.
Protein values of dialysed allergen extracts determined by Lowry, modified Lowry (trichloroacetic acid precipitation of the proteins) and dye-binding assay were compared. The influence of different parameters on the modified Lowry was examined. The reproducibility of the modified Lowry was checked with three independent measurements. For the examination of recovery a constant amount of 6-grass pollen allergen proteins was added to the samples of the standardized human serum albumin prepared for the calibration curve. The samples were measured by modified Lowry. The mean of the ratio between the protein values of the dialysed allergen extracts obtained by modified Lowry and those obtained by classical Lowry was 3.59 (coefficient of variation Cv = 45%). The mean of the ratio between the protein values of the allergen extracts obtained by modified Lowry and dye-binding assay was 1:0.71 (Cv = 31%). Phenol interfered with the modified Lowry. Phenolic allergen extracts showed higher "protein values" than non-phenolic allergen extracts. This influence could be reduced by a second precipitation of the dissolved precipitate. The precipitation of non-phenolic dialysed aqueous allergen extracts was complete after the first trichloroacetic acid precipitation. By incubating samples with the Folin-Ciocalteu's reagent at 55 degrees C in a waterbath, the time necessary for developing the colour could be reduced from 45 min to 5 min. Protein measurements by modified Lowry of a 6-grass pollen allergen extract in three different laboratories showed good reproducibility. For these extract 785 micrograms protein/ml (Cv = 4%) could be measured.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

18.
In studies of physical performance comprising muscle strength and power, a vertical jump is a test method that frequently is used. It is important to have access to accurate measuring tools providing data with high reproducibility. Studies have shown that body composition also may play an important part in physical performance. The purpose of this study was to determine test-retest reliability for 3 different kinds of vertical jumps and to correlate jump height with body composition. Thirty-four normally trained subjects (women n = 17) between 18 and 25 years participated. Test-retest, on 3 kinds of vertical jumps, was performed with a median of 7 days between jumps. Methods used were a countermovement jump (CMJ) on a contact mat, with and without arm swing, and an Abalakow jump (AJ) using measuring tape, with arm swing. Body composition was assessed with the use of bioelectric impedance analysis. The results showed that high intraclass correlation coefficients (ICCs) were observed between testing occasions for all 3 vertical jumps (ICC between 0.48 and 0.88). The AJ in women presented the lowest ICC. Also the correlation between CMJ and AJ was high (rs = 0.88). Moderate-to-high correlations could be shown between body composition and CMJ in women (rs = -0.57-0.76). In conclusion, very high test-retest reliability for CMJ on a contact mat was found. For the AJ using a measuring tape, ICC were overall high, but a moderate nonsignificant ICC were found in women, indicating poor reproducibility. The data from the CMJ and AJ may be compared if approximately 25% of the AJ value is subtracted. In practice, this means that vertical jump tests have high reproducibility and can be used as measures of power development.  相似文献   

19.
Determination of the thermal thresholds is used clinically for evaluation of peripheral nervous system function. The aim of this study was to evaluate reliability of the method of levels performed with a new, low cost device for determining cutaneous temperature sensitivity. Nineteen male subjects were included in the study. Thermal thresholds were tested on the right side at the volar surface of mid-forearm, lateral surface of mid-upper arm and front area of mid-thigh. Thermal testing was carried out by the method of levels with an initial temperature step of 2°C. Variability of thermal thresholds was expressed by means of the ratio between the second and the first testing, coefficient of variation (CV), coefficient of repeatability (CR), intraclass correlation coefficient (ICC), mean difference between sessions (S1-S2diff), standard error of measurement (SEM) and minimally detectable change (MDC). There were no statistically significant changes between sessions for warm or cold thresholds, or between warm and cold thresholds. Within-subject CVs were acceptable. The CR estimates for warm thresholds ranged from 0.74°C to 1.06°C and from 0.67°C to 1.07°C for cold thresholds. The ICC values for intra-rater reliability ranged from 0.41 to 0.72 for warm thresholds and from 0.67 to 0.84 for cold thresholds. S1-S2diff ranged from -0.15°C to 0.07°C for warm thresholds, and from -0.08°C to 0.07°C for cold thresholds. SEM ranged from 0.26°C to 0.38°C for warm thresholds, and from 0.23°C to 0.38°C for cold thresholds. Estimated MDC values were between 0.60°C and 0.88°C for warm thresholds, and 0.53°C and 0.88°C for cold thresholds. The method of levels for determining cutaneous temperature sensitivity has acceptable reliability.  相似文献   

20.
PurposeDosiomics allows to parameterize regions of interest (ROIs) and to produce quantitative dose features encoding the spatial and statistical distribution of radiotherapy dose. The stability of dosiomics features extraction on dose cube pixel spacing variation has been investigated in this study.Material and MethodsBased on 17 clinical delivered dose distributions (Pn), dataset has been generated considering all the possible combinations of four dose grid resolutions and two calculation algorithms. Each dose voxel cube has been post-processed considering 4 different dose cube pixel spacing values: 1x1x1, 2x2x2, 3x3x3 mm3 and the one equal to the planning CT. Dosiomics features extraction has been performed from four different ROIs. The stability of each extracted dosiomic feature has been analyzed in terms of coefficient of variation (CV) intraclass correlation coefficient (ICC).ResultsThe highest CV mean values were observed for PTV ROI and for the grey level size zone matrix features family. On the other hand, the lowest CV mean values have been found for RING ROI for the grey level co-occurrence matrix features family. P3 showed the highest percentage of CV >1 (1.14%) followed by P15 (0.41%), P1 (0.29%) and P13 (0.19%). ICC analysis leads to identify features with an ICC >0.95 that could be considered stable to use in dosiomic studies when different dose cube pixel spacing are considered, especially the features in common among the seventeen plans.ConclusionConsidering the observed variability, dosiomic studies should always provide a report not only on grid resolution and algorithm dose calculation, but also on dose cube pixel spacing.  相似文献   