首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 812 毫秒
1.
Results are presented of an investigation on electric and magnetic fields leaking from inductive (magnetic) heaters that are used for thermal processing of high-power electron tubes and lasers in an industrial plant. Measurements of electric and magnetic fields were done using both commercially available and laboratory-developed instrumentation. Isotropic H-field sensors were developed to allow quantitative evaluation of high-intensity magnetic fields. Ten induction heaters with nominal A.C. power ranging from 2.5 kW to 15 kW and operating at frequencies between 300 kHz and 790 kHz were surveyed. Electric field strengths up to 8 kV/m and magnetic field strengths up to 20 A/m were measured.  相似文献   

2.
We have plotted data from a number of studies on the range of radiofrequency (RF) field levels associated with a variety of environmental and occupational sources. Field intensity is shown in units of volts/meter (V/m) for electric field strength and amps/meter (A/m) for magnetic field strength. Duty factors, modulation frequencies, and modulation indices are also reported for some sources. This paper is organized into seven sections, each cataloging sources into appropriate RF frequency bands from very-low frequency (VLF) to super-high frequency (SHF), and covers frequencies from 10 kHz to 30 GHz. Sources included in this summary are the following: Coast Guard navigational transmitters, a Navy VLF transmitter, computer visual display terminals (VDTs), induction stoves or range tops, industrial induction and dielectric heaters, radio and television broadcast transmitters, amateur and citizens band (CB) transmitters, medical diathermy and electrosurgical units, mobile and handheld transmitters, cordless and cellular telephones, microwave ovens, microwave terrestrial relay and satellite uplinks, and police, air traffic, and aircraft onboard radars. For the sources included in this summary, the strongest fields are found near industrial induction and dielectric heaters, and close to the radiating elements or transmitter leads of high power antenna systems. Handheld transmitters can produce near fields of about 500 V/m at the antenna. Fields in the general urban environment are principally associated with radio and TV broadcast services and measure about 0.1 V/m root-mean-square (rms). Peak fields from air traffic radars sampled in one urban environment were about 10 V/m, 300 times greater than the rms value of 0.03 V/m when the duty factor associated with antenna rotation and pulsing are factored in. Bioelectromagnetics 18: 563–577, 1997. Published 1997 Wiley-Liss, Inc.
  • 1 This article is a US Government work and, as such, is in the public domain in the United States of America.
  •   相似文献   

    3.
    Data are presented on ankle-specific SARs and foot currents as a function of strengths of radio-frequency electromagnetic fields encountered by operators of dielectric heaters. The determination of foot currents was based on near-field exposures in which reactive coupling dominates, and which can result in substantial SARs in exposed workers. The operators were located less than one wavelength from--usually within one meter of--the dielectric heaters, which generated fields at frequencies from 6.5 to 65 MHz. At distances normally assumed by workers, maximal strengths of electric fields ranged from 10(4) to 2.4 x 10(6) V2/m2; maximal strengths of magnetic fields ranged from 5.0 x 10(-3) to 33.3 A2/m2. Currents through both feet to ground were measured while operators stood where they normally worked. Maximal currents ranged from 3 to 617 mA, rms. Nearly 27 percent of the dielectric heaters induced foot currents that exceeded the 200-mA limit that has been proposed for a new ANSI C95.1 standard. Twenty percent of the heaters induced foot currents that exceeded 350 mA. SARs in ankles were calculated from foot currents, and they approximated 5 W/kg at 100 mA, 29 W/kg at 250 mA, and 57 W/kg at 350 mA. The maximal SAR in the ankle was approximately 176 W/kg at 617 mA.  相似文献   

    4.
    由于电子设备的广泛使用,人类已经越来越多地暴露在射频磁场的辐射下,但射频磁场的辐射效应却一直不明确.采用全细胞膜片钳技术,记录2 450 MHz射频磁场辐射对小鼠脑皮层神经元延迟整流钾电流IK的影响.利用Ansoft HFSS软件对6 dB全向天线建模仿真,验证距天线2~3 cm处磁场分布均匀,使用Agilent E5070B网络分析仪经该天线发射出2 450 MHz输出功率为39.81 mW电磁场,对细胞进行刺激.实验发现,2 450 MHz低功率射频磁场暴露5、10和15 min对IK均有明显的抑制作用;显著影响IK激活特性,对照组与磁场暴露组半数激活电压分别为(-1.13±2.32)mV和(19.52±1.03)mV(n=10, P <0.05);斜率因子分别为(23.21±3.29)mV和(13.95±1.27)mV(n=10, P <0.05).结果表明,低功率射频磁场通过减小延迟整流钾通道电流,影响神经元的生理功能,为进一步研究电磁辐射所引发的生物学效应提供了一种新的方法.  相似文献   

    5.
    This study reports the dosimetry performed to support an experiment that measured physiological responses of seated volunteer human subjects exposed to 220 MHz fields. Exposures were performed in an anechoic chamber which was designed to provide uniform fields for frequencies of 100 MHz or greater. A vertical half-wave dipole with a 90 degrees reflector was used to optimize the field at the subject's location. The vertically polarized E field was incident on the dorsal side of the phantoms and human volunteers. The dosimetry plan required measurement of stationary probe drift, field strengths as a function of distance, electric and magnetic field maps at 200, 225, and 250 cm from the dipole antenna, and specific absorption rate (SAR) measurements using a human phantom, as well as theoretical predictions of SAR with the finite difference time domain (FDTD) method. A NBS (National Bureau of Standards, now NIST, National Institute of Standards and Technology, Boulder, CO) 10 cm loop antenna was positioned 150 cm to the right, 100 cm above and 60 cm behind the subject (toward the transmitting antenna) and was read prior to each subject's exposure and at 5 min intervals during all RF exposures. Transmitter stability was determined by measuring plate voltage, plate current, screen voltage and grid voltage for the driver and final amplifiers before and at 5 min intervals throughout the RF exposures. These dosimetry measurements assured accurate and consistent exposures. FDTD calculations were used to determine SAR distribution in a seated human subject. This study reports the necessary dosimetry to precisely control exposure levels for studies of the physiological consequences of human volunteer exposures to 220 MHz.  相似文献   

    6.
    The main purpose of this work was to investigate the fluctuation of Greek indoor electromagnetic field (EMF) intensity values and identify peaks that might occur. The scientific interest is mainly focused on the bands of extremely low-frequency (ELF) magnetic fields and radiofrequency (RF) electric fields which have been suggested to be possibly carcinogenic to humans by the Scientific Committee on Emerging and Newly Identified Health Risks (SCENIHR).Electromagnetic radiation (EMR) measurements were performed in a variety of indoor dwellings, in Attica and in the islands of Zakynthos and Lesvos.A total number of 4540 measurements were taken in a wide frequency range (50 Hz–2100 MHz) of which 3301 in Attica, 963 in Lesvos and 276 in Zakynthos.Statistical analysis of the data revealed specific statistically significant differences between the mean values of the electric (ELF and RF) but not the magnetic (ELF) field strengths measured at different distances from the EMF source, as well as between some of the mean values of the RF electric field at different bands. Some statistically significant differences between mean electric field values at different geographic locations were also identified.As far as the RF electric field is concerned, the maximum values, in most cases, were below 0.5 V/m, however increased values above 1 V/m and up to 5.6 V/m were occasionally observed. The ELF magnetic field values were lower than 1 μT. It may be concluded that overall, the observed indoor EMF intensity values remained well below domestic and European established limits.  相似文献   

    7.
    Erythrocyte hemolysis by radiofrequency fields   总被引:1,自引:0,他引:1  
    A field-strength-dependent hemolytic effect of continuous-wave radiofrequency (RF) exposure in vitro has been demonstrated. Erythrocytes in whole heparinized rabbit blood were hemolyzed by a 2-h exposure to 50- or 100-MHz RF fields at field strengths of greater than 4 V/cm. An effect of comparable magnitude resulted from exposure to 10-MHz RF at a field strength of 9 V/cm. Sample temperatures were maintained at 22.5 degrees +/- 0.2 degrees C. There was no apparent involvement of heating or temperature gradients, nor were there any RF exposure effects on cellular K+ or Na+ concentration, nor on pH. The mechanism of the hemolytic effect is not known. Since the percentage of lysed erythrocytes was less than 1% and there was an absence of effects on cellular cation concentrations, RF radiation may have irreversibly altered the plasma membrane permeability of a sensitive subpopulation of red cells (possibly aged cells) leading to osmotic lysis. RF radiation at these frequencies appears to affect red cells in a manner that is qualitatively and quantitatively different from microwave radiation.  相似文献   

    8.
    Electromagnetic field exposure and health among RF plastic sealer operators   总被引:2,自引:0,他引:2  
    Operators of RF plastic sealers (RF operators) are an occupational category highly exposed to radiofrequency electromagnetic fields. The aim of the present study was to make an appropriate exposure assessment of RF welding and examine the health status of the operators. In total, 35 RF operators and 37 controls were included. The leakage fields (electric and magnetic field strength) were measured, as well as induced and contact current. Information about welding time and productivity was used to calculate time integrated exposure. A neurophysiological examination and 24 h ECG were also carried out. The participants also had to answer a questionnaire about subjective symptoms. The measurements showed that RF operators were exposed to rather intense electric and magnetic fields. The mean values of the calculated 6 min, spatially averaged E and H field strengths, in line with ICNIRP reference levels, are 107 V/m and 0.24 A/m, respectively. The maximum measured field strengths were 2 kV/m and 1.5 A/m, respectively. The induced current in ankles and wrists varied, depending on the work situation, with a mean value of 101 mA and a maximum measured value of 1 A. In total, 11 out of 46 measured RF plastic sealers exceeded the ICNIRP reference levels. RF operators, especially the ready made clothing workers had a slightly disturbed two-point discrimination ability compared to a control group. A nonsignificant difference between RF operators and controls was found in the prevalence of subjective symptoms, but the time integrated exposure parameters seem to be of importance to the prevalence of some subjective symptoms: fatigue, headaches, and warmth sensations in the hands. Further, RF operators had a significantly lower heart rate (24 h registration) and more episodes of bradycardia compared to controls.  相似文献   

    9.
    10.
    Multiple power-density windows and their possible origin   总被引:4,自引:0,他引:4  
    We have previously reported that in vitro exposure of chick forebrain tissue to 50-MHz radiofrequency (RF) electromagnetic radiation, amplitude modulated (AM) at 16 Hz, would enhance the efflux of calcium ions within only two power-density ranges: one from 1.44 to 1.67 mW/cm2, and the other including 3.64 mW/cm2. No effect on efflux occurred at 0.37, 0.72, 2.17, and 4.32 mW/cm2. We confirmed and extended these results by testing at another set of power densities, which included the range of the previous study. Forebrain tissue from 1-7-day-old chickens was labeled in vitro with radioactive calcium ions (30 min, at 37 degrees C), rinsed, placed in a physiological salt solution, and then exposed for 20 min to 50-MHz radiation, AM at 16 Hz, in a transverse electric and magnetic field (TEM) cell maintained at 37 degrees C. The solution was then assayed for radioactive calcium activity. A power-density series was tested. An enhanced efflux of calcium ions was found at 1.75, 3.85, 5.57, 6.82, 7.65, 7.77, and 8.82 mW/cm2; no change was observed at 0.75, 2.30, 4.50, 5.85, 7.08, 8.19, 8.66, 10.6, and 14.7 mW/cm2. Power density is converted to specific absorption rate (SAR) by 0.36 mW/kg per mW/cm2. Even the highest SAR tested (0.005 W/kg) is much too low to result in generalized heating of the sample and thus to be the underlying cause of the enhanced response. A hypothetical mechanism is proposed involving dynamic systems that may account for the power-density dependency as well as for part of the frequency dependency observed with both modulated RF radiation and extremely-low-frequency (ELF) fields.  相似文献   

    11.
    A space efficient, whole body microwave exposure system for unrestrained laboratory animals utilizing a flared parallel plate waveguide is described. The system comprises an Iridium wireless signal source, signal generator, power supply and amplifier (400 W), a coax to waveguide transition, an open ended, flared parallel plate waveguide, and animal exposure area with a dipole field sensing antenna. Across the waveguide aperture the system provides uniform exposure (+/-3 dB incident RF power density) for small animals (rats, mice or hamsters) in up to 18 standard cages for housing groups of animals. Overall system dimensions are 3.6 m (d)x2.4 m (w)x1.6 m (h). Operating at 1.62 GHz, the system provided average power density of 3.7 W/m(2) in the cage area, resulting in a calculated whole body dose of 0.07 W/kg and a calculated average brain dose of 0.19 W/kg.  相似文献   

    12.
    In situ radiofrequency (RF) exposure of the different RF sources is characterized in Reading, United Kingdom, and an extrapolation method to estimate worst-case long-term evolution (LTE) exposure is proposed. All electric field levels satisfy the International Commission on Non-Ionizing Radiation Protection (ICNIRP) reference levels with a maximal total electric field value of 4.5 V/m. The total values are dominated by frequency modulation (FM). Exposure levels for LTE of 0.2 V/m on average and 0.5 V/m maximally are obtained. Contributions of LTE to the total exposure are limited to 0.4% on average. Exposure ratios from 0.8% (LTE) to 12.5% (FM) are obtained. An extrapolation method is proposed and validated to assess the worst-case LTE exposure. For this method, the reference signal (RS) and secondary synchronization signal (S-SYNC) are measured and extrapolated to the worst-case value using an extrapolation factor. The influence of the traffic load and output power of the base station on in situ RS and S-SYNC signals are lower than 1 dB for all power and traffic load settings, showing that these signals can be used for the extrapolation method. The maximal extrapolated field value for LTE exposure equals 1.9 V/m, which is 32 times below the ICNIRP reference levels for electric fields.  相似文献   

    13.
    Rabbit polymorphonuclear leucocytes (PMN, neutrophils) obtained from peritoneal exudate were exposed in vitro for one-half or one hour to continuous wave or amplitude-modulated (20-Hz) 100-MHz RF radiation in a temperature-controlled coaxial exposure chamber at field strengths from 2.5 to 4.1 V/cm (SARs of 120 to 341 W/kg). RF exposure at 37 +/- 0.2 degrees C had no detectable effect on PMN viability or phagocytosis compared to sham-exposed cells simultaneously subjected to the same time-temperature regime. Temperature control studies indicated that at 37 degrees C no effect on PMN viability would be expected but phagocytosis would be reduced by approximately 6%/degrees C temperature increase. The absence of an effect of RF exposure suggests that there was minimal undetected intrasample heating and that phagocytosis was not affected by 100-MHz RF radiation under the conditions of this study.  相似文献   

    14.
    This study reports the dosimetry performed to support an experiment that measured physiological responses of volunteer human subjects exposed to the resonant frequency for a seated human adult at 100 MHz. Exposures were performed in an anechoic chamber which was designed to provide uniform fields for frequencies of 100 MHz or greater. A half wave dipole with a 90 degrees reflector was used to optimize the field at the subject location. The dosimetry plan required measurement of transmitter harmonics, stationary probe drift, field strengths as a function of distance, electric and magnetic field maps at 200, 225, and 250 cm from the dipole antenna, and specific absorption rate (SAR) measurements using a human phantom, as well as theoretical predictions of SAR with the finite difference time domain (FDTD) method. On each exposure test day, a measurement was taken at 225 cm on the beam centerline with a NBS E field probe to assure consistently precise exposures. A NBS 10 cm loop antenna was positioned 150 cm to the right, 100 cm above, and 60 cm behind the subject and was read at 5 min intervals during all RF exposures. These dosimetry measurements assured accurate and consistent exposures. FDTD calculations were used to determine SAR distribution in a seated human subject. This study reports the necessary dosimetry for work on physiological consequences of human volunteer exposures to 100 MHz.  相似文献   

    15.
    The growing use of wireless local area networks (WLAN) in schools has prompted a study to investigate exposure to the radio frequency (RF) electromagnetic fields from Wi-Fi devices. International guidelines on limiting the adverse health effects of RF, such as those of ICNIRP, allow for time-averaging of exposure. Thus, as Wi-Fi signals consist of intermittent bursts of RF energy, it is important to consider the duty factors of devices in assessing the extent of exposure and compliance with guidelines. Using radio packet capture methods, the duty factor of Wi-Fi devices has been assessed in a sample of 6 primary and secondary schools during classroom lessons. For the 146 individual laptops investigated, the range of duty factors was from 0.02 to 0.91%, with a mean of 0.08% (SD 0.10%). The duty factors of access points from 7 networks ranged from 1.0% to 11.7% with a mean of 4.79% (SD 3.76%). Data gathered with transmit time measuring devices attached to laptops also showed similar results. Within the present limited sample, the range of duty factors from laptops and access points were found to be broadly similar for primary and secondary schools. Applying these duty factors to previously published results from this project, the maximum time-averaged power density from a laptop would be 220 μW m(-2), at a distance of 0.5 m and the peak localised SAR predicted in the torso region of a 10 year old child model, at 34 cm from the antenna, would be 80 μW kg(-1).  相似文献   

    16.
    The aim of this study was to design, implement and analyze a space-efficient setup for the whole-body exposure of unrestrained Wistar rats to radiofrequency (RF) electromagnetic fields at 900 MHz. The setup was used for 2 years in a cocarcinogenesis study and part of it for 5 weeks in a central nervous system (CNS) study. Up to 216 rats could be placed in separate cages in nine different exposure chambers on three racks requiring only 9 m2 of floor area (24 rats per m2). Chambers were radial transmission lines (RTL), where the rats could freely move in their cages where food and drinking water was provided ad libitum except during RF exposure periods. Dosimetrical analysis was based on FDTD computations with heterogeneous rat models and was validated with calorimetrical measurements carried out with homogeneous phantoms. The estimated whole-body average specific absorption rates (SAR) of rats were 0 (sham), 0.4, and 1.3 W/kg in the cocarcinogenesis study and 0 (sham), 0.27, and 2.7 W/kg in the CNS study with an estimated uncertainty of 3 dB (K = 2). The instantaneous and lifetime variations of whole-body average SAR due to the movement of rats were estimated to be 2.3 and 1.3 dB (K = 1), respectively.  相似文献   

    17.
    Medical Physics Department (Medical School, University of Thessaly) participated in a Greek National EMF research program (EDBM34) with the scope to measure and evaluate radiofrequency (RF) exposure (27–3000 MHz) in areas of sensitive land use. A thousand (1000) measurements were carried out at two “metropolitan locations” (Athens and Thessaloniki: 624 points) and several rest urban/rural locations (376 points). SRM 3006 spectrum analyzer manufactured by Narda Safety Test Solutions was used. The broadband mean electric field in metropolitan areas was 0.41 V/m, while in the rest of Greece was 0.36 V/m. In metropolitan areas, the predominant RF source was the TV and Radio FM signals (36.2% mean contribution to the total RF exposure level). In the rest areas, the predominant source was the systems of the meteorological and military/defensive service (31.1%). The mobile sector contributed 14.9% in metropolitan areas versus 12.2% in the rest of Greece. The predominant mobile source was 900 MHz in both cases (4.5% in metropolitan areas vs. 3.3% in the rest of Greece). The total exposure from all RF sources complied with the International Commission on Non-Ionizing Radiation Protection (ICNIRP) 2020 safety guidelines [ICNIRP, 2020]. The maximum exposure level was 0.129% of the limit for the metropolitan areas vs. 0.110% for the rest of Greece. Nonremarkable differences between metropolitan areas' exposure and the rest of Greece. In most cases, new 5 G antennas will be added to the existing base stations. Thus, the total exposure may be increased, leading to higher safety distances. © 2023 Bioelectromagnetics Society.  相似文献   

    18.
    The structure of the RF magnetic field in the vicinity of a loop antenna operating in the whistler frequency range has been studied experimentally and theoretically. The experiments were performed over a wide frequency range at different values of the plasma density, electron temperature, and ambient magnetic field strength. It is shown that, when a loop antenna is smaller than the wavelength of a quasi-longitudinal whistler, the structure of the magnetic field of such an antenna is nearly the same as that of the field of a current-carrying loop in vacuum; otherwise, the RF field is localized near the antenna wire. The results of numerical calculations agree with the measured field distributions. The antenna field is calculated by expanding it in the eigenmodes of a magnetized plasma with allowance for not only propagating but also nonpropagating (exponentially decaying) waves, which make the main contribution to the near field. An analytic estimate of the depth to which the RF magnetic field of a loop antenna penetrates into the plasma is obtained.  相似文献   

    19.
    A miniaturized probe was designed and built to provide detailed data on fields induced by a uniform 60-Hz magnetic field in homogeneous models of rat and human. The probe employed three silver wires twisted and potted in an 8-cm hypodermic needle. The exposed tips of the wires formed three sensing electrodes with a centered ground; highly sensitive voltage measurements were enabled by a lock-in amplifier. Tests were conducted in a 1-mT rms field that was uniform within +/- 5%. The models were made by casting 1.5% agar at 1-S/m conductivity into plastic-foam molds. The rat model was scaled 1:1 as an adult (22 cm length; mass about 640 g). The human model was scaled 1:4 as an adult (height = 46.5 cm; mass 1.4 kg). The probe was inserted into each model in several regions, and readings of induced fields were made under different exposure geometries. Maximal strengths of fields induced near the surface of the torso were as high as 120 microV/cm in the laterally exposed rat model. Data extrapolated from the quarter-scale human model revealed that an induced field as high as 700 microV/cm could occur at the torso of a frontally exposed human adult. An overall size-scale factor of about 5 appears to be appropriate for experimental exposures of rats that are intended to simulate currents induced in human beings by magnetic fields. The average strength of electric fields induced in the torso by a 1-mT magnetic field is comparable to that by a vertical electric-field at 60 kV/m and 28 kV/m, respectively, for the rat and human.  相似文献   

    20.
    For the first time, in situ electromagnetic field exposure of the general public to fields from long term evolution (LTE) cellular base stations is assessed. Exposure contributions due to different radiofrequency (RF) sources are compared with LTE exposure at 30 locations in Stockholm, Sweden. Total exposures (0.2–2.6 V/m) satisfy the International Commission on Non‐Ionizing Radiation Protection (ICNIRP) reference levels (from 28 V/m for frequency modulation (FM), up to 61 V/m for LTE) at all locations. LTE exposure levels up to 0.8 V/m were measured, and the average contribution of the LTE signal to the total RF exposure equals 4%. Bioelectromagnetics 31:576–579, 2010. © 2010 Wiley‐Liss, Inc.  相似文献   

    设为首页 | 免责声明 | 关于勤云 | 加入收藏