首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The purpose of the present study was to determine the day-to-day reliability in stride characteristics in rats during treadmill walking obtained with two-dimensional (2D) motion capture. Kinematics were recorded from 26 adult rats during walking at 8 m/min, 12 m/min and 16 m/min on two separate days. Stride length, stride time, contact time, swing time and hip, knee and ankle joint range of motion were extracted from 15 strides. The relative reliability was assessed using intra-class correlation coefficients (ICC(1,1)) and (ICC(3,1)). The absolute reliability was determined using measurement error (ME). Across walking speeds, the relative reliability ranged from fair to good (ICCs between 0.4 and 0.75). The ME was below 91 mm for strides lengths, below 55 ms for the temporal stride variables and below 6.4° for the joint angle range of motion. In general, the results indicated an acceptable day-to-day reliability of the gait pattern parameters observed in rats during treadmill walking. The results of the present study may serve as a reference material that can help future intervention studies on rat gait characteristics both with respect to the selection of outcome measures and in the interpretation of the results.  相似文献   

2.
This paper investigates the effect of three important variables on signal use, theoretically and experimentally. We present a simple model and a corresponding experiment that investigates the combined effects of uncertainty about action, signal reliability and signal cost. Our experiment uses techniques drawn from the psychology laboratory to test the behavior of captive blue jays Cyanocitta cristata solving a simple feeding problem. In the experiment, individual jays must choose which of two keys to peck; one key leads to food, but the other does not. In addition, the jays can choose to see a signal that provides information about which key provides a food reward. We find that these three variables interact to determine signal use crudely as our model predicts. Specifically, we find maximal signal use when uncertainty is high, signals are reliable and signal cost is low, but the effects of these variables on signal use do not combine additively. A change in any single variable can abolish signal use. While our results agree qualitatively with our simple model, we also find – in agreement with previous studies – that subjects show a bias against signal use. Specifically, they tend to ignore signals and rely on prior information about the correct action in ‘intermediate’ conditions. These results are important for two reasons. First, they replicate earlier results from our laboratory using a different preparation. Second, they highlight the central interaction between uncertainty and reliability that determines the value of signals for receivers. This is significant because game theoretical models of signaling emphasize the problem of ‘reliability,’ but they pay little attention to the fundamental interaction between reliability and uncertainty.  相似文献   

3.
This report addresses some of the statistical problems that are encountered when the test/retest recording reliability of fatigue-related parameters of the EMG power spectrum is evaluated. It can be shown that some classical methods for reliability assessment such as correlational procedures are unsuitable for this purpose. Because the EMG power spectrum fatigue parameter depends on metabolic changes in muscle tissue, it is suggested that methods similar to those used in the evaluation of bioequivalence studies may be more appropriate in the assessment of such test/retest results.  相似文献   

4.
5.
In large-scale heterogeneous cluster computing systems, processor and network failures are inevitable and can have an adverse effect on applications executing on such systems. One way of taking failures into account is to employ a reliable scheduling algorithm. However, most existing scheduling algorithms for precedence constrained tasks in heterogeneous systems only consider scheduling length, and not efficiently satisfy the reliability requirements of task. In recognition of this problem, we build an application reliability analysis model based on Weibull distribution, which can dynamically measure the reliability of task executing on heterogeneous cluster with arbitrary networks architectures. Then, we propose a reliability-driven earliest finish time with duplication scheduling algorithm (REFTD) which incorporates task reliability overhead into scheduling. Furthermore, to improve system reliability, it duplicates task as if task hazard rate is more than threshold \(\theta \) . The comparison study, based on both randomly generated graphs and the graphs of some real applications, shows that our scheduling algorithm can shorten schedule length and improve system reliability significantly.  相似文献   

6.
The purpose of this study was to determine the intratester reliability of surface electromyography (EMG) assessment of the gluteus medius muscle in healthy people and people with chronic nonspecific low back pain (CNLBP) during barefoot walking. Gluteus medius muscle activity was measured twice in 40 people without and 30 people with CNLBP approximately 7 days apart. Walking gluteus medius muscle activity was normalised to maximal voluntary isometric contractions during side-lying hip abduction with manual resistance. Good intratester reliability (ICC > 0.75) was found for mean, peak, and peak to peak amplitude for healthy people. Only mean amplitude demonstrated good intratester reliability in those with CNLBP. Peak amplitude and peak to peak amplitude of the gluteus medius muscle of those with CNLBP, and the time of peak amplitude in both groups, demonstrated moderate reliability (ICC ranged from 0.50 to 0.58). Moderate to large standard error of measurement and minimal detectable change values were reported for outcome measurements. These results suggest that potentially large levels of random error can occur between sessions. Future research can build on this study for those with pathology and attempt to establish change values for EMG that are clinically meaningful.  相似文献   

7.
In this paper we propose constructing an improved two-level neural network to predict protein secondary structure. Firstly, we code the whole protein composition information as the inputs to the first-level network besides the evolutionary information. Secondly, we calculate the reliability score for each residue position based on the output of the first-level network, and the role of the second-level network is to take full advantage of the residues with a higher reliability score to impact the neighboring residues with a lower one for improving the whole prediction accuracy. Thirdly, considering it is indeed a problem that the target protein can be lost in the multiple sequence alignment we propose to code single sequence into the second-level network. The experimental results show that our proposed method can efficiently improve the prediction accuracy.  相似文献   

8.
Measuring physical fitness becomes more important. Yet most instruments depend upon the function of the lower extremities. Hence, we investigated whether an adapted submaximal arm crank test on an ergometer for the upper body is reliable to use, and if the submaximal test for the arm crank ergometer is valid compared to the test on the bicycle ergometer. Different types of reliability measures of the adapted submaximal test on an arm crank ergometer were assessed in healthy volunteers, such as test-retest, interobserver, interergometer, and between arm crank and bicycle ergometer. A crossover design was used. The measurements were proportionally distributed over 30 volunteers. Based on the intraclass correlation coefficient (ICC) and the magnitude of within-person differences, we revealed a good reliability of the submaximal test. For the test-retest reliability, the ICC was 0.76, the interobserver reliability was 0.82, and the interergometer reliability 0.63. In addition, the criterion validity was also tested by comparing the calculated VO2max during the submaximal test on the arm crank ergometer and on the bicycle ergometer. Between VO2max on the arm crank and bicycle ergometer, an ICC of 0.64 was found. The results of the submaximal test on the arm crank ergometer are reliable and valid as compared with those on the bicycle crank ergometer. We showed that the submaximal test on the arm crank ergometer is suitable for measuring physical fitness in healthy people. We expect that disabled people can use this submaximal test on the arm crank ergometer for measuring their physical fitness, also.  相似文献   

9.
We introduce the relationship between excess noise in Optoelectronic Coupled Devices (OCDs) and their interior defectsand explain how low-fiequency noise can be used to estimate their reliability.Using concepts from the biological immunesystem and its process of identifying invaders,we present a system for estimation of the reliability of OCDs.The system hasexpressions for the antigen (excess noise),lymphocyte (criterion) and the role of the lymphocyte eliminating unreliable devices.A genetic algorithm was used to estimate the components parameters of the noise spectrum for estimating the reliability ofOCDs.The experimental results demonstrated that this method is reliable,adaptable and practical.  相似文献   

10.
Motor learning is driven by movement errors. The speed of learning can be quantified by the learning rate, which is the proportion of an error that is corrected for in the planning of the next movement. Previous studies have shown that the learning rate depends on the reliability of the error signal and on the uncertainty of the motor system’s own state. These dependences are in agreement with the predictions of the Kalman filter, which is a state estimator that can be used to determine the optimal learning rate for each movement such that the expected movement error is minimized. Here we test whether not only the average behaviour is optimal, as the previous studies showed, but if the learning rate is chosen optimally in every individual movement. Subjects made repeated movements to visual targets with their unseen hand. They received visual feedback about their endpoint error immediately after each movement. The reliability of these error-signals was varied across three conditions. The results are inconsistent with the predictions of the Kalman filter because correction for large errors in the beginning of a series of movements to a fixed target was not as fast as predicted and the learning rates for the extent and the direction of the movements did not differ in the way predicted by the Kalman filter. Instead, a simpler model that uses the same learning rate for all movements with the same error-signal reliability can explain the data. We conclude that our brain does not apply state estimation to determine the optimal planning correction for every individual movement, but it employs a simpler strategy of using a fixed learning rate for all movements with the same level of error-signal reliability.  相似文献   

11.
ABSTRACT.   Understanding variation in the detectability of birds is fundamental to determining the reliability of survey methods. We examined the influence of lunar light conditions on the detection probability of Whip-poor-wills through repeated sampling of 78 point count stations over two lunar cycles. The probability of detection was positively related to moonlight intensity measured as the percentage of moon-face illuminated and moon height above the horizon. These results were used to show how the reliability of long-term monitoring strategies can be improved by sampling design. Surveys conducted on nights when the moon-face was >50% illuminated were less variable and provided more statistical power to long-term monitoring results compared to surveys that were conducted across all nights. Stratifying surveys for Whip-poor-wills during bright moonlight provides greater statistical power for monitoring programs, which inevitably allows better scientific conclusions to be drawn from collected data.  相似文献   

12.
Estimation of the inclination of the occlusal plane and its spatial orientation during the insertion of plaster casts in the articulators space, and control during the clinical phase of the prosthetic work, is one of the key problems in dental prosthetics. The aim of this investigation was to compare the relations of the basic roentgencephalometric parameters applied and to determine their reliability. Five angular variables were analysed: OP-MdP, OP-PP, OP-CP, OP-FP and OP-SNP, on a sample of 86 radiographs of subjects with almost normal occlusion by applying basic statistical parameters and the correlation's analysis. The results gave mean values of the investigated variables with estimation of their variability and level of mutual correlation, which can be used when determining individual inclination of the occlusal plane. Parameters FP and SNP showed significant stability and reliability which can be successfully applied in prosthodontics.  相似文献   

13.
Cache structures in a multicore system are more vulnerable to soft errors due to high transistor density. Protecting all caches unselectively has notable overhead on performance and energy consumption. In this study, we propose asymmetrically reliable caches to supply reliability need of the system using sufficient additional hardware under the performance and energy constraints. In our framework, a chip multiprocessor is composed of a high reliability core which has ECC protection, and a set of low reliability cores which have no protection on their data caches. Between two types of cores, there is also a middle-level reliability core which has only parity check. Application threads are mapped on the different cores in terms of reliability based on their critical data usage. The experimental results for selected applications show that our proposed techniques improve reliability with considerable performance and energy overhead on the average compared to traditional unsafe caches.  相似文献   

14.
Internal quality control (IQC) is a critical component of laboratory quality management, and IQC products can determine the reliability of testing results. In China, given the fact that most blood transfusion compatibility laboratories do not employ IQC products or do so minimally, there is a lack of uniform and standardized IQC methods. To explore the reliability of IQC products and methods, we studied 697 results from IQC samples in our laboratory from 2012 to 2014. The results showed that the sensitivity and specificity of the IQCs in anti-B testing were 100% and 99.7%, respectively. The sensitivity and specificity of the IQCs in forward blood typing, anti-A testing, irregular antibody screening, and cross-matching were all 100%. The reliability analysis indicated that 97% of anti-B testing results were at a 99% confidence level, and 99.9% of forward blood typing, anti-A testing, irregular antibody screening, and cross-matching results were at a 99% confidence level. Therefore, our IQC products and methods are highly sensitive, specific, and reliable. Our study paves the way for the establishment of a uniform and standardized IQC method for pre-transfusion compatibility testing in China and other parts of the world.  相似文献   

15.
Many methods developed for estimating the reliability of protein–protein interactions are based on the topology of protein–protein interaction networks. This paper describes a new reliability measure for protein–protein interactions, which does not rely on the topology of protein interaction networks, but expresses biological information on functional roles, sub-cellular localisations and protein classes as a scoring schema. The new measure is useful for filtering many spurious interactions, as well as for estimating the reliability of protein interaction data. In particular, the reliability measure can be used to search protein–protein interactions with the desired reliability in databases. The reliability-based search engine is available at http://yeast.hpid.org. We believe this is the first search engine for interacting proteins, which is made available to public. The search engine and the reliability measure of protein interactions should provide useful information for determining proteins to focus on.  相似文献   

16.

Background

The “Timed Up and Go” (TUG) is a widely used measure of physical functioning in older people and in neurological populations, including Parkinson’s Disease. When using an inertial sensor measurement system (instrumented TUG [iTUG]), the individual components of the iTUG and the trunk kinematics can be measured separately, which may provide relevant additional information.

Objective

The aim of this study was to determine intra-rater, inter-rater and test-retest reliability of the iTUG in patients with Parkinson’s Disease.

Methods

Twenty eight PD patients, aged 50 years or older, were included. For the iTUG the DynaPort Hybrid (McRoberts, The Hague, The Netherlands) was worn at the lower back. The device measured acceleration and angular velocity in three directions at a rate of 100 samples/s. Patients performed the iTUG five times on two consecutive days. Repeated measurements by the same rater on the same day were used to calculate intra-rater reliability. Repeated measurements by different raters on the same day were used to calculate intra-rater and inter-rater reliability. Repeated measurements by the same rater on different days were used to calculate test-retest reliability.

Results

Nineteen ICC values (15%) were ≥ 0.9 which is considered as excellent reliability. Sixty four ICC values (49%) were ≥ 0.70 and < 0.90 which is considered as good reliability. Thirty one ICC values (24%) were ≥ 0.50 and < 0.70, indicating moderate reliability. Sixteen ICC values (12%) were ≥ 0.30 and < 0.50 indicating poor reliability. Two ICT values (2%) were < 0.30 indicating very poor reliability.

Conclusions

In conclusion, in patients with Parkinson’s disease the intra-rater, inter-rater, and test-retest reliability of the individual components of the instrumented TUG (iTUG) was excellent to good for total duration and for turning durations, and good to low for the sub durations and for the kinematics of the SiSt and StSi. The results of this fully automated analysis of instrumented TUG movements demonstrate that several reliable TUG parameters can be identified that provide a basis for a more precise, quantitative use of the TUG test, in clinical practice.  相似文献   

17.
The aims of the present study were: (a) to determine the number of familiarization trials required to establish a high degree of reliability in measures of power output during maximal intermittent cycling; and (b) to examine the reliability of those same measures after familiarization had been established. On separate days over a 3-week period, 2 groups of 7 recreationally active men completed 8 trials of 1 of 2 maximal (20 x 5-second) intermittent cycling tests with contrasting recovery periods (10-seconds or 30-seconds). Significant (p < 0.05) between-trial differences were detected in post-hoc tests involving trials 1 and 2 only. Within-subject test-retest reliability was therefore assessed across trials 3-8. Apart from values of maximum power output in Protocol 1 (10-second recovery periods), all remaining measures of power output showed high degrees of within-subject test-retest reliability (coefficient of variation: 2.4-3.7%). The results of the present study indicate that in subjects unfamiliar with maximal intermittent cycling, high degrees of reliability in many performance measures can be achieved following the completion of 2 familiarization trials.  相似文献   

18.
Lee JH  Park JH  Lee SH  Park CS  Jin DI 《Theriogenology》2004,62(8):1452-1458
Fluorescence in situ hybridization (FISH) is a sensitive technique for molecular diagnosis of chromosomes on single cells and can be applied to sex determination of embryos. The objective has been to develop an accurate and reliable bovine Y chromosome-specific DNA probe in order to sex biopsed blastomeres derived from IVF bovine embryos by FISH. Bovine Y chromosome-specific PCR product derived from BtY2 sequences was labeled with biotin-16-dUTP (BtY2-L1 probe), and FISH was performed on karyoplasts of biopsed blastomeres and matched demi-embryos. Our FISH signal was clearly detected in nuclei of blastomeres of male embryos. FISH analysis of bovine embryos gave high reliability (96%) between biopsied blastomeres and matched demi-embryos. These results indicated that the BtY2-L1 bovine Y chromosome-specific FISH probe was an effective probe for bovine embryo sexing, and the FISH technique of probe detection could improve the efficiency and reliability.  相似文献   

19.

Background

The Clubfoot Assessment Protocol (CAP) was developed for follow-up of children treated for clubfoot. The objective of this study was to analyze reliability and validity of the six items used in the domain CAPMotion Quality using inexperienced assessors.

Findings

Four raters (two paediatric orthopaedic surgeons, two senior physiotherapists) used the CAP scores to analyze, on two different occasions, 11 videotapes containing standardized recordings of motion activity according to the domain CAPMotion Quality These results were compared to a criterion (two raters, well experienced CAP assessors) for validity and for checking for learning effect. Weighted kappa statistics, exact percentage observer agreement (Po), percentage observer agreement including one level difference (Po-1) and amount of scoring scales defined how reliability was to be interpreted. Inter- and intra rater differences were calculated using median and inter quartile ranges (IQR) on item level and mean and limits of agreement on domain level. Inter-rater reliability varied between fair and moderate (kappa) and had a mean agreement of 48/88% (Po/Po-1). Intra -rater reliability varied between moderate to good with a mean agreement of 63/96%. The intra- and inter-rater differences in the present study were generally small both on item (0.00) and domain level (-1.10). There was exact agreement of 51% and Po-1 of 91% of the six items with the criterion. No learning effect was found.

Conclusion

The CAPMotion quality can be used by inexperienced assessors with sufficient reliability in daily clinical practice and showed acceptable accuracy compared to the criterion.  相似文献   

20.
The aim of this report has been to present results concerning analytical quality controls of Hg analysis of fish and sediment, analyses of Fe, Ca, total-P, K, pH, alkalinity, conductivity, colour and hardness (Ca + Mg) of lake water samples. Despite the fact that these are standard parameters in many regular water control programs, there are major differences in the reliability with which these parameters can be determined. The focus here is on an overall inter-laboratory comparison between the parameters. Six laboratories have been involved in the analysis. Selected results: pH gives the lowest (average) relative standard deviation (error), about 2 %; conductivity gives an error of about 5–7 %; alkalinity yields an average error of as much as 13–25 %, which is the largest among the parameters studied here; colour also gives a high error, 9–15 %; hardness gives a relative standard deviation of about 6–7 %. Of the other parameters (i. e., Hg, Fe, Ca and P), Hg gives the best reliability and Fe and P the lowest. To have knowledge of the reliability of the analytical data is of paramount importance in most control programs and research projects.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号