首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
cis-Diamminedichloroplatinum(II) (DDP) was measured in plasma ultrafiltrate following derivatization with sodium diethyldithiocarbamate (DDTC) by quantitation against a nickel chloride internal standard. A chloroform extract containing the Pt(DDTC)2 and Ni(DDTC)2 complexes was separated by reversed-phase high-performance liquid chromatography on a C18 radial compression column. The complex was eluted with methanol/water, 4/1, at a flow rate of 1.5 ml/min, and was detected at 254 nm. The limit of sensitivity was 0.1 microgram/ml DDP in the ultrafiltrate. This analytical approach was validated by comparison to graphite furnace atomic absorption spectrophotometric determinations of duplicate samples. There was clearly a component of the ultrafiltrable platinum present that was resistant to derivatization by DDTC. Evidence is presented that this component, presumably Pt(II) complexed with endogenous small molecules, is non cytotoxic and, hence, that this method may be selective for "active Pt(II)." This method offers an advantage over atomic absorption determination of total platinum in ultrafiltrate which does not discriminate between active and inactive forms, and over off-line FAA detection of parent DDP in HPLC eluates which ignores other active forms. Using this technique we have measured the pharmacokinetics of DDTC-reactive Pt(II) in humans after either i.v. infusion or infusion of DDP into the peritoneal cavity of patients with ovarian carcinoma.  相似文献   

2.
A rapid and simple high-performance liquid chromatographic (HPLC) method has been developed and validated for determination of scopoletin in rat plasma using psoralen as internal standard. Chromatographic separation was achieved on a C(18) column using methanol and distilled water (49:51, v/v) containing 0.05% (v/v) phosphoric acid as mobile phase. The UV detector was set at 345 nm. The calibration curve was linear over the range of 0.165-9.90 microg/ml with a correlation coefficient of 0.9994. The recovery for plasma samples of 0.165, 1.32 and 6.60 microg/ml was 93.2%, 95.9% and 95.5%, respectively. The RSD of intra- and inter-day assay variations was less than 6.7%. This HPLC assay is a precise and reliable method for the analysis of scopoletin in pharmacokinetic studies.  相似文献   

3.
Carboplatin is a platinum analogue that is used in a number of chemotherapeutic regimens for solid tumors, such as lung and ovarian carcinomas. Most often characterization of carboplatin's pharmacokinetic properties is based on measurement of platinum, rather than intact carboplatin. We have developed a sensitive LC-MS method for the determination of intact carboplatin in plasma ultrafiltrate and in tumor tissue. Carboplatin was extracted from rat plasma ultrafiltrate and tumor samples using solid-phase extraction cartridges and analyzed using reversed-phase chromatography with positive electrospray ionization followed by mass spectrometric detection. Using 50 microliter of plasma ultrafiltrate or 140 microliter of tumor homogenate supernatant, the extraction afforded a recovery of 58.7 and 45.8% for plasma and tumor, respectively. The mobile phase was 5% acetonitrile in 0.5% acetic acid at 0.2 ml/min that yielded a retention time of carboplatin of 2.2 min. The method has been validated at carboplatin plasma ultrafiltrate concentrations from 0.07 to 2.5 microgram/ml, and from 0.03 to 1.3 microgram/ml in tumor homogenates. The main advantages of this method compared with earlier methods are the ability to measure intact carboplatin in a sensitive and specific manner.  相似文献   

4.
A liquid chromatographic method is described for the simultaneous determination of cefalexin and trimethoprim in dog plasma. A simple protein precipitation procedure was adopted for the sample preparation with satisfactory extraction recoveries for both analytes. Chromatographic separation of the analytes was achieved on a C(18) column using a mixture of 2 mol/l formate buffer (pH 3.5), methanol and acetonitrile (22:7:7, v/v/v) containing a 0.002 mol/l sodium dodecyl sulfate as mobile phase and detection was performed at 240 nm. The linearity was obtained over the concentration ranges of 1.0-100.0 microg/ml for cefalexin and 0.5-50.0 microg/ml for trimethoprim. For each level of QC samples including the lower limit of quantification, both inter- and intra-day precisions (R.S.D.) were < or =14.0% for cefalexin and < or =11.4% for trimethoprim, and accuracy (RE) was -1.4% for cefalexin and -3.0% for trimethoprim. The present LC method was successfully applied to the pharmacokinetic studies of coformulated cefalexin dispersible tablets after oral administration to beagle dogs.  相似文献   

5.
A liquid chromatographic-tandem mass spectrometric method (LC-MS/MS) for the determination of ulifloxacin, the active metabolite of prulifloxacin, in human plasma is described. After sample preparation by protein precipitation with methanol, ulifloxacin and ofloxacin (internal standard) were chromatographically separated on a C(18) column using a mobile phase consisting of methanol, water and formic acid (70:30:0.2, v/v/v) at a flow rate of 0.5 ml/min and then were detected using MS/MS by monitoring their precursor-to-product ion transitions, m/z 350-->m/z 248 for ulifloxacin and m/z 362-->m/z 261 for ofloxacin, in selected reaction monitoring (SRM) mode. Positive electrospray ionization was used for the ionization process. The linear range was 0.025-5.0 microg/ml for ulifloxacin with a lower limit of quantitation of 0.025 microg/ml. Within- and between-run precision was less than 6.6 and 7.8%, respectively, and accuracy was within 2.0%. The recovery ranged from 92.1 to 98.2% at the concentrations of 0.025, 0.50 and 5.0 microg/ml. Compared with the reported LC method, the present LC-MS/MS method can directly determine the ulifloxacin in human plasma without any need of derivatization. The present method has been successfully used for the pharmacokinetic studies of a prulifloxacin formulation product after oral administration to healthy volunteers.  相似文献   

6.
Liquid chromatographic assay for dicloxacillin in plasma   总被引:2,自引:0,他引:2  
A simple high-performance liquid chromatographic method for the determination of dicloxacillin in plasma has been developed. The method only requires 0.5 ml of plasma, phosphate buffer solution (pH = 4.7), acidification with 0.5N hydrochloride acid and liquid extraction with dichloromethane. Posterior evaporation of organic under nitrogen steam and redissolution in mobile phase is carried out. The analysis was performed on a Spherisorb C18 (5 microm) column, using methanol -0.05 M phosphate buffer, pH = 4.7 (75:25; v/v) as mobile phase, with ultraviolet detection at 220 nm. Results showed that the assay is sensitive: 0.5 microg/ml. The response is linear in the range of 0.5 - 10 microg/ml. Maximum inter-day coefficient of variation was 12.4%. Mean extraction recovery obtained was 96.95%. Stability studies showed that the loss was not higher than 10%, samples are stable at room temperature for 6 h, at -20 Celsius for 2 months, processed samples were stable at least for 24 h and also after two freeze-thaw cycles. The method has been used to perform pharmacokinetic and bioequivalence studies in humans.  相似文献   

7.
A high-performance liquid chromatographic (HPLC) method was developed using solid-phase extraction, o-phthalaldehyde (OPA) derivatization and fluorescence detection for the determination of the direct thrombin inhibitor bivalirudin in human plasma and urine. The use of this assay will facilitate the study of the pharmacodynamics of bivalirudin in studies of special patient populations. A C(18) bioanalytical column at a flow rate of 1 ml/min with an aqueous trifluoroacetic acid (0.1% TFA in deionized water, pH 2.2, v/v) mobile phase and methanol gradient was used. The assay demonstrated linearity from 3 to 20 microg/ml bivalirudin in plasma, with a detection limit of 1 microg/ml. The method was utilized in a study evaluating the pharmacokinetic and pharmacodynamic effects of bivalirudin in patients undergoing percutaneous coronary interventions (PCIs).  相似文献   

8.
We have developed a specific assay for cisplatin in human plasma ultrafiltrate (PUF) and cell culture medium ultrafiltrate (MUF) using HPLC on-line with inductively coupled plasma mass spectrometry (ICP-MS). Separation of cisplatin (6 min) and monohydrated cisplatin (12 min) was achieved using a muBondapak C(18) column (Waters) and a mobile phase (0.075 mM sodium dodecyl sulfate and 3% methanol, adjusted to pH 2.5 with triflic acid) pumped at a flow rate of 0.5 mL/min. The analytes were detected with little background interference by ICP-MS monitoring of platinum masses (m/z 194/195). Calibration curves were linear over three orders of magnitude (0.05-8 microM) and the limit of quantitation was 0.1 microM. Intra- and inter-assay accuracy (range 91.6-113%) and precision (range 1.00-12.3%) were acceptable for PUF and MUF. The method was applied to determining cisplatin during ex vivo incubation of the drug in whole human blood at 37 degrees C. In conclusion, a specific, sensitive and reliable HPLC-ICP-MS assay has been established for determining intact cisplatin in PUF and MUF.  相似文献   

9.
The development and validation of a high-performance liquid chromatographic and UV detection method was accomplished for quantitative determination of levamisole in chicken tissues, eggs and plasma. The chromatographic separation was achieved on Luna 5 microm C(18) column using a mobile phase of 0.2% acetic acid in water:methanol (50:50 (v/v)) and Pic B-7 low UV reagent and the pH was adjusted to 7.31 with ammonium hydroxide and UV wavelength was 225 nm. Limits of quantification were 0.025 microg/g for all tissues and 0.003 microg/ml for plasma. Limit of detection was 0.001 microg/g for tissues and plasma.  相似文献   

10.
A high-performance liquid chromatographic method using liquid-liquid extraction was developed for the determination of 1-(3-fluoro-4-hydroxy-5-mercaptomethyl-tetrahydrofuran-2-yl)-5-methyl-1H-pyrimidine-2,4-dione (l-FMAUS; I) in rat plasma and urine. A 100 microl aliquot of distilled water containing l-cysteine (100 mg/ml) was added to a 100 microl aliquot of biological sample. l-Cysteine was employed to protect binding between the 5'-thiol of I and protein in the biological sample. After vortex-mixing for 30s and adding a 50 microl aliquot of the mobile phase containing the internal standard (10 microg/ml of 3-aminophenyl sulfone), 1 ml of ethyl acetate was used for extraction. After vortex-mixing, centrifugation, and evaporating the ethyl acetate, the residue was reconstituted with a 100 microl aliquot of the mobile phase. A 50 microl aliquot was injected onto a C(18) reversed-phase column. The mobile phases, 50 mM KH(2)PO(4) (pH = 2.5):acetonitrile (85:15, v/v) for rat plasma and 50 mM KH(2)PO(4) (pH 2.5):acetonitrile:methanol (85:10:5, v/v/v) for urine samples, were run at a flow-rate of 1.2 ml/min. The column effluent was monitored by an ultraviolet detector set at 265 nm. The retention times for I and the internal standard were approximately 9.7 and 12.5 min, respectively, in plasma samples and the corresponding values in urine samples were 16.8 and 14.9 min. The quantitation limits of I in rat plasma and urine were 0.1 and 0.5 microg/ml, respectively.  相似文献   

11.
20 (R,S)-Ginsenoside-Rg2, an anti-shock agent, is prescribed as a racemate. To analyze simultaneously the enantiomers of 20 (R)-ginsenoside-Rg2 and 20 (S)-ginsenoside-Rg2 in plasma, a simple and reproducible high-performance liquid chromatographic (HPLC) method has been developed. The enantiomeric separation and determination were successfully achieved using a Diamonsil ODS C18 reversed-phase column (5 microm, 250 mm x 4.6 mm) with an RP18 (5 microm) guard column and a mobile phase of MeOH-aq. 4% H3PO4 (65:35, v/v, pH 5.1) with UV detection at 203 nm. Both enantiomers, 20 (R)-ginsenoside-Rg2 and 20 (S)-ginsenoside-Rg2, were well separated at 14.5 min and 13.6 min, respectively. The linear ranges of the standard curves were 2.0-250 microg/ml. The intra- and inter-day precision (R.S.D.) were 相似文献   

12.
The aim of this study was to develop a rapid and sensitive HPLC method with UV detection for the estimation of imatinib from the plasma of patients with chronic myeloid leukemia (CML). The robustness of the method was checked by conducting first dose pharmacokinetics on blood samples from four patients who had been administered Gleevec (100 mg) in an oral dose. Samples were prepared in a simple and single step by precipitating the plasma proteins with methanol and injecting 50 microl aliquot from supernatant was subjected for analysis. Assay was conducted using a C8 column (250 mm x 4.6 mm, 5 microm particle size) under isocratic elution with 0.02 M potassium dihydrogen phosphate-acetonitrile (7:3, v/v) at a flow rate of 1 ml/min and detected using photodiode array at 265 nm. Calibration plots in spiked plasma were linear in a concentration range of 0.05-25 microg/ml. The inter and intra-day variation of standard curve was <4% (R.S.D.). This method could be a simple and quick method for the estimation of imatinib from the patient's plasma.  相似文献   

13.
The method of high-performance liquid chromatography (HPLC) with UV-vis detection was used and validated for the simultaneous determination of six flavonoids (puerarin, rutin, morin, luteolin, quercetin, kaempferol) and troxerutin in rat urine and chicken plasma. Chromatographic separation was performed using a VP-ODS column (150 mm x 4.6 mm, 5.0 microm) maintained at 35.0 degrees C. The mobile phase was a mixture of water, methanol and acetic acid (57:43:1, v/v/v, pH 3.0) at the flow rate of 0.8 mL/min. Six flavonoids and troxerutin were analyzed simultaneously with good separation. On optimum conditions, calibration curves were found to be linear with the ranges of 0.10-70.00 microg/mL (puerarin, rutin, morin, luteolin, quercetin, kaempferol) and 0.50-350.00 microg/mL (troxerutin). The detection limits were 0.010-0.050 microg/mL. The method was validated for accuracy and precision, and it was successfully applied to determine drug concentrations in rat urine and chicken plasma samples from rat and chicken that had been orally administered with six flavonoids and troxerutin.  相似文献   

14.
Ertapenem is a new once-a-day antibiotic with excellent coverage of common community gram negative and gram positive aerobes and anaerobes. It demonstrates nonlinear protein binding in human plasma (about 94% bound). An assay for unbound drug was developed to study the pharmacokinetics of unbound ertapenem in plasma. Unbound drug is separated from plasma samples (1.0 ml) by ultrafiltration using a Centrifree((R)) centrifugal filter device. Ertapenem (vulnerable to hydrolysis of the beta-lactam moiety) is stabilized in the filtrate by adding an equal volume of 0.1 M MES buffer, pH 6.5 and then is analyzed by reversed-phase high-performance liquid chromatography (HPLC) with ultraviolet (UV) absorbance detection (300 nm). Non-specific binding to the Centrifree((R)) device is <3%. A suitable internal standard is not available. The assay is specific and linear over the concentration range of 0.25 to 100 microgram/ml in plasma filtrate. The lower limit of quantitation (LLOQ) is 0.25 microgram/ml. Intra-day precision is C.V.<10% and accuracy ranges from 97 to 101% of nominal concentration. Inter-day precision and accuracy were determined using quality control samples (QCs) prepared in plasma ultrafiltrate at 0.5, 12 and 80 microgram/ml and stored at -70 degrees C with stabilizer. Inter-day assay accuracy and precision ranged from 100 to 111% of nominal concentration and 1.8 to 5.3% C.V. (n=40), respectively. The assay has been used to analyze plasma samples from subjects receiving 500 and 2000 mg i.v. doses of ertapenem (30 min infusion).  相似文献   

15.
A liquid chromatography-mass spectrometry method is described for the determination of tetramethylpyrazine (TMP) and its active metabolite, 2-hydroxymethyl-3,5,6-trimethylpyrazine (HTMP) in dog plasma. This method involves a plasma clean-up step using protein precipitation procedure followed by LC separation and positive electrospray ionization mass spectrometry detection (ESI-MS). Chromatographic separation of the analytes was achieved on a C18 column using a mobile phase of methanol, water and acetic acid (50:50:0.6, v/v/v) at a flow rate of 1.0 ml/min. Selected ion monitoring (SIM) mode was used for analyte quantitation at m/z 137.2 for TMP, m/z 153.2 for HTMP and m/z 195.2 for caffeine. The linearity was obtained over the concentration ranges of 20-6000 ng/ml for TMP and 20-4000 ng/ml for HTMP and the lower limit of quantitation was 20 ng/ml for both analytes. For each level of QC samples, both inter- and intra-day precisions (R.S.D.) were 相似文献   

16.
A rapid and simple high-performance liquid chromatographic (HPLC) assay for the determination of paeoniflorin in rat hippocampus was developed in this study. The chromatographic analysis was carried out using reversed-phase isocratic elution with a Zorbax SB-C(18) column, a mobile phase of methanol-water (32:68, v/v), and detection by ultraviolet (UV) absorption at 233 nm. The lower limits of quantitation (LLQ) were 1 microg/ml for paeoniflorin. The calibration curve for paeoniflorin was linear (r = 0.9999) over the concentration range of 1-50 microg/ml. The coefficients of variation of intra- and inter-day assays were 7.00, 0.58, 1.46% and 5.48, 1.79, 1.70% at concentrations of 1, 10, 50 microg/ml, respectively. The recoveries of paeoniflorin from rat hippocampus were 98.28 +/- 2.14, 98.96 +/- 1.48, and 95.34 +/- 0.92 at concentrations of 1, 10 and 50 microg/ml, respectively. Stability studies showed that paeoniflorin was stable at temperatures of 2-8 degrees C in methanol for at least 20 days. The method was applied to determine the time course of paeoniflorin in rat hippocampus, following the administration of a 60 mg/kg i.v. dose of paeoniflorin in Paeoniae Radix extract to a male Wistar rat.  相似文献   

17.
A sample treatment procedure and high-sensitive liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) method for quantitative determination of fexofenadine in human plasma was developed for a microdose clinical trial with a cold drug, i.e., a non-radioisotope-labeled drug. Fexofenadine and terfenadine, as internal standard, were extracted from plasma samples using a 96-well solid-phase extraction plate (Oasis HLB). Quantitation was performed on an ACQUITY UPLC system and an API 5000 mass spectrometer by multiple reaction monitoring. Chromatographic separation was achieved on an XBridge C18 column (100 mm x 2.1 mm i.d., particle size 3.5 microm) using acetonitrile/2 mM ammonium acetate (91:9, v/v) as the mobile phase at a flow rate of 0.6 ml/min. The analytical method was validated in accordance with the FDA guideline for validation of bioanalytical methods. The calibration curve was linear in the range of 10-1000 pg/ml using 200 microl of plasma. Analytical method validation for the clinical dose, for which the calibration curve was linear in the range of 1-500 ng/ml using 20 microl of plasma, was also conducted. Each method was successfully applied for making determinations in plasma using LC/ESI-MS/MS after administration of a microdose (100 microg solution) and a clinical dose (60 mg dose) in eight healthy volunteers.  相似文献   

18.
A simple high-performance liquid chromatographic (HPLC) method was developed for the simultaneous determination of iohexol, iothalamate, p-aminohippuric acid (PAH) and n-acetyl-p-aminohippuric acid (n-acetyl-PAH) in human plasma and urine. A C(18) column at a flow rate of 1 ml/min with an aqueous mobile phase of trifluoroacetic acid (0.1% TFA in deionized water (pH 2.2), v/v) and methanol gradient was used for component separation. The plasma and urine assay demonstrated linearity from 10 to 50 microg/ml for iohexol and iothalamate, 5 to 40 microg/ml for PAH and 2.5 to 40 microg/ml for n-acetyl-PAH. The HPLC plasma and urine results obtained for PAH were used to calculate the subject kidney effective renal plasma flow (ERPF) and the iohexol results were used to calculate the subject kidney glomerular filtration rate (GFR). The HPLC results for PAH were then compared to an alternative colorimetric method for analyzing PAH to determine if subject metabolism (acetylation) of PAH affected the ERPF results obtained using the colorimetric method, the subsequent ERPF/GFR ratio and clinical impression of subject patient kidney function. The method was utilized in several different clinical studies evaluating the effect of kidney function from medications (phase IV evaluations) marketed for patients with cardiovascular disease.  相似文献   

19.
The pharmacokinetics and tissue distribution profiles of a novel series of traditional Chinese medicine-platinum (TCM-Pt) compounds [Pt(C(8)H(8)O(5))(NH(2)R)(2)]: 1 (where R=H), 3 (R=CH(3)) and 5 (R=C(6)H(10)), were studied in Sprague-Dawley rats following a single bolus intravenous (i.v.) injection. Platinum concentrations in total plasma, plasma ultrafiltrate, urine and tissues were measured by flameless atomic absorption spectroscopy. Pharmacokinetic studies showed that plasma concentrations of total and free platinum for the novel TCM-Pt compounds as well as cisplatin and carboplatin declined in a biexponential manner with a short distribution half-life (t(1/2alpha): 0.12-0.34h). Compared with cisplatin, the novel TCM-Pt compounds had a longer elimination half-life (t(1/2beta)), larger dose normalized area under the curve (AUC/D), larger volume of distribution at steady-state (V(ss)), slower clearance (CL) of free platinum and higher percentage of cumulative urinary excretion (CUE), which can be attributed to their lower chemical reactivities. In tissues, the highest Pt concentrations were found in the kidney, followed by the liver and the lowest in the heart; no Pt was detected in the brain. Twenty-four hours after drug administration, platinum concentrations in tissues were significantly lower for the novel TCM-Pt compounds. These findings suggest that the novel compounds might afford higher clinical efficacy and reduced systemic side effects, when compared with cisplatin.  相似文献   

20.
A chromatographic method for determination of leucine aminopeptidase (LAP) activity in complex matrices is described. L-Leucine-beta-naphthylamide was used as the substrate and its hydrolytic product, beta-naphthylamine, was monitored by fluorescence at 280 nm excitation and 400 nm emission wavelengths. Under optimized conditions, the components in the incubation mixture were baseline separated and eluted out of a large-pore (300 angstroms) reversed-phase C4 column (RPC4) within 15 min with a non-linear gradient elution of methanol (0.05% (v/v) trifluoroacetic acid additive). The detection limit of the hydrolytic product reached 0.35 pmol at three time signal-to-noise (S/N) ratio with 5 microl sample injection. The method showed a wide dynamic range for quantitation of both the hydrolytic product (10 ng/ml to 80 microg/ml) and LAP (0.1-46.0 microg/ml) with correlation coefficient larger than 0.998 and reproducibility <3 and 10% R.S.D. (n=3), respectively. A fairly broad range of incubation time could be selected within 1 h. The LAP activities and concentrations in rabbit serum, tears, and mouse lens homogenates were determined to be 41.8 (0.3 mg/ml), 2.8 (40.0 microg/ml), and 1.6 pmol/(microl min) (17.5 microg/ml), respectively, with reproducibility of 2-9% R.S.D. (n=3) and intra- and inter-day variation for the retention time of the hydrolytic product being <1% R.S.D. (n=3). The results indicate that the present method is rapid and sensitive as compared to the conventional one.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号