首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 448 毫秒
1.
Citalopram (CITA) is available as a racemic mixture and as a pure enantiomer. Its antidepressive action is related to the (+)-(S)-CITA and to the metabolite (+)-(S)-demethylcitalopram (DCITA). In the present investigation, a method for the analysis of CITA and DCITA enantiomers in human and rat plasma was developed and applied to the study of pharmacokinetics. Plasma samples (1 ml) were extracted at pH 9.0 with toluene:isoamyl alcohol (9:1, v/v). The CITA and DCITA enantiomers were analyzed by LC-MS/MS on a Chiralcel OD-R column. Recovery was higher than 70% for both enantiomers. The quantification limit was 0.1 ng/ml, and linearity was observed up to 500 ng/ml plasma for each CITA and DCITA enantiomer. The method was applied to the study of the kinetic disposition of CITA administered in a single oral dose of 20 mg to a healthy volunteer and in a single dose of 20 mg/kg (by gavage) to Wistar rats (n = 6 for each time). The results showed a higher proportion of the (-)-(R)-CITA in human and rat plasma, with S/R AUC ratios for CITA of 0.28 and 0.44, respectively. S/R AUC ratios of DCITA were 0.48 for rats and 1.04 for the healthy volunteer.  相似文献   

2.
A sensitive liquid chromatography-electrospray ionization tandem mass spectrometry method (LC/ESI/MS/MS) for the enantioselective determination of (S)-(+)-BMS-204352, a potent and specific maxi-K channel opener, in human, rat and dog plasma was developed. (S)-(+)-BMS-204352, its enantiomer (R)-(--)-BMS-204353 and the internal standard (13C-deuterated racemate of (S)-(+)-BMS-204352) were extracted from plasma using toluene. Chromatographic separation for the enantiomers was achieved on a Chiralcel OD-H analytical column with a run time of 8 min. An aqueous mobile phase modifier was added post column to enhance the mass spectrometer sensitivity. ESI mass spectra were acquired in the negative mode with selected reaction monitoring. The limit of quantitation (LLOQ) is 0.10 ng/mL for human plasma assay. Samples from a clinical study and two animal studies were processed using these procedures. Based on the in vivo data, lack of inversion of (S)-(+)-BMS-204352 to (R)-(--)-BMS-204353 was demonstrated in human, rat and dog after administration of the drug. A sensitive non-enantioselective LC/ESI/MS/MS assay has also been developed for (S)-(+)-BMS-204352 which uses a similar extraction procedure with a C18 column with a limit of quantitation at 0.05 ng/mL. Human study samples were analyzed by both methods and the correlation coefficient between both sets of data is greater than 0.99.  相似文献   

3.
M Enquist  J Hermansson 《Chirality》1989,1(3):209-215
A method for the determination of (R)- and (S)-atenolol in human plasma and urine is described. The enantiomers of atenolol are extracted into dichloromethane containing 3% heptafluorobutanol followed by acetylation with acetic anhydride at 60 degrees C for 2 h. The acetylated enantiomers were separated on a chiral alpha 1-AGP column. Quantitation was performed using fluorescence detection. A phosphate buffer pH 7.1 (0.01 M phosphate) containing 0.25% (v/v) acetonitrile was used as mobile phase. The described procedure allows the detection of less than 6 ng of each enantiomer in 1 ml plasma. The relative standard deviation is 4.4% at 30 ng/ml of each enantiomer in plasma. The plasma concentration of (R)- and (S)-atenolol did not differ significantly in two subjects who received a single tablet of racemic atenolol. The R/S ratio of atenolol in urine was approximately 1.  相似文献   

4.
A selective, accurate and reproducible high-performance liquid chromatographic (HPLC) method for the separation of individual enantiomers of DRF 2725 [R(+)-DRF 2725 and S(-)-DRF 2725 or ragaglitazar] was obtained on a chiral HPLC column (Chiralpak). During method optimization, the separation of enantiomers of DRF 2725 was investigated to determine whether mobile phase composition, flow-rate and column temperature could be varied to yield the base line separation of the enantiomers. Following liquid-liquid extraction, separation of enantiomers of DRF 2725 and internal standard (I.S., desmethyl diazepam) was achieved using an amylose based chiral column (Chiralpak AD) with the mobile phase, n-hexane-propanol-ethanol-trifluoro acetic acid (TFA) in the ratio of 89.5:4:6:0.5 (v/v). Baseline separation of DRF 2725 enantiomers and I.S., free from endogenous interferences, was achieved in less than 25 min. The eluate was monitored using an UV detector set at 240 nm. Ratio of peak area of each enantiomer to I.S. was used for quantification of plasma samples. Nominal retention times of R(+)-DRF 2725, S(-)-DRF 2725 and I.S. were 15.8, 17.7 and 22.4 min, respectively. The standard curves for DRF 2725 enantiomers were linear (R(2) > 0.999) in the concentration range 0.3-50 microg/ml for each enantiomer. Absolute recovery, when compared to neat standards, was 70-85% for DRF 2725 enantiomers and 96% for I.S. from rat plasma. The lower limit of quantification (LLOQ) for each enantiomers of DRF 2725 was 0.3 microg/ml. The inter-day precisions were in the range of 1.71-4.60% and 3.77-5.91% for R(+)-DRF 2725, S(-)-DRF 2725, respectively. The intra-day precisions were in the range of 1.06-11.5% and 0.58-12.7% for R(+)-DRF 2725, S(-)-DRF 2725, respectively. Accuracy in the measurement of quality control (QC) samples was in the range 83.4-113% and 83.3-113% for R(+)-DRF 2725, S(-)-DRF 2725, respectively. Both enantiomers and I.S. were stable in the battery of stability studies viz., bench-top (up to 6 h), auto-sampler (up to 12 h) and freeze/thaw cycles (n = 3). Stability of DRF 2725 enantiomers was established for 15 days at -20 degrees C. The application of the assay to a pharmacokinetic study of ragaglitazar [S(-)-DRF 2725] in rats is described. It was unequivocally demonstrated that ragaglitazar does not undergo chiral inversion to its antipode in vivo in rat plasma.  相似文献   

5.
BAPTA free acid was identified as the main metabolic product of 1,2-bis(2-aminophenoxy)ethane-N,N,N',N'-tetraacetic acid tetra(actoxymethyl ester) (BAPTA-AM), a neuroprotective agent in cerebral ischemia, in rats. In this paper, liquid chromatography-ultraviolet (LC-UV) and mass spectrometry/mass spectrometry (LC-MS/MS) methods were employed for the determination of BAPTA free acid in rat urine and feces and rat plasma, respectively. By liquid-liquid extraction and LC-UV analysis, a limit of quantitation of 1000 ng/ml using 0.2 ml rat urine for extraction and 250 ng/ml using 1 ml rat fecal homogenate supernatant for extraction could be reached. The assay was linear in the range of 1000-50,000 ng/ml for rat urine and 250-10,000 ng/ml for rat fecal homogenate supernatant. Because the sensitivity of the LC-UV method was apparently insufficient for evaluating the pharmacokinetic profile of BAPTA in rat plasma, a LC-MS/MS method was subsequently developed for the analysis of BAPTA free acid. By protein precipitation and LC-MS/MS analysis, the limit of quantitation was 5 ng/ml using 0.1 ml rat plasma and the linear range was 5.0-500 ng/ml. Both methods were validated and can be used to support a thorough preclinical pharmacokinetic evaluation of BAPTA-AM liposome injection.  相似文献   

6.
An automated online sample extraction method for rat plasma was developed and validated for the quantification of (R)- and (S)-propranolol following the intravenous administration of either the racemate or the individual enantiomers at 5 mg/kg. A dual-column extraction system coupled to a chiral stationary phase (CSP) was used in conjunction with liquid chromatography-tandem mass spectrometry. In this method, two Oasis HLB extraction columns (50x1.0 mm) in parallel were used for online plasma sample purification and teicoplanin CSP (Chirobiotic T) was used for the enantiomeric separation. This method allowed the use of one of the extraction columns for purification while the other was being equilibrated. Hence, the time required for re-conditioning the extraction columns did not contribute to the total analysis time per sample, which resulted in a relatively shorter run time and higher throughput. The lower limit of detection was 0.5 ng/ml and the lower limit of quantification was 2 ng/ml for each enantiomer using 25 microl of rat plasma. The method was validated with a linear calibration curve between 2 and 2000 ng/ml for (R)- and (S)-propranolol, respectively. The intra- and inter-day precision (C.V.) was no more than 7.6% and the accuracy of the assay was between 92 and 103%. The teicoplanin CSP proved to be rugged with excellent reproducibility of chromatographic parameters.  相似文献   

7.
A chiral liquid chromatography/mass spectrometry (LC/MS) bioanalytical procedure has been developed for the analysis of the antimalaric agent Fenozan B07 in dog plasma. Normal-phase chromatography involving a phenylcarbamate derivative of cellulose coated on silica gel as the chiral stationary phase was used to resolve (-)-(S,S)-B07 from (+)-(R,R)-B07. The enantiomers were detected by a mass spectrometer equipped with an atmospheric pressure chemical ionization (APCI) interface operated in the negative ion mode. A mass spectrum, characterized by a base peak of m/z 285, was obtained for each enantiomer. The m/z 285 ion was very specific for the analysis of both enantiomers in the plasma. The selected ion monitoring analysis of the plasma samples was therefore performed at m/z 285 for quantitative purposes. The enantiomers were extracted from the plasma in a basic medium and purified by solid-phase extraction using a hydrophilic-lipophilic balanced sorbent. A lower limit of quantification of 2 ng/mL in plasma was achieved for both enantiomers. The quantitative procedure reported in this study was highly specific and sensitive, and was validated according to the FDA guidance on bioanalytical method validation.  相似文献   

8.
20 (R,S)-Ginsenoside-Rg2, an anti-shock agent, is prescribed as a racemate. To analyze simultaneously the enantiomers of 20 (R)-ginsenoside-Rg2 and 20 (S)-ginsenoside-Rg2 in plasma, a simple and reproducible high-performance liquid chromatographic (HPLC) method has been developed. The enantiomeric separation and determination were successfully achieved using a Diamonsil ODS C18 reversed-phase column (5 microm, 250 mm x 4.6 mm) with an RP18 (5 microm) guard column and a mobile phase of MeOH-aq. 4% H3PO4 (65:35, v/v, pH 5.1) with UV detection at 203 nm. Both enantiomers, 20 (R)-ginsenoside-Rg2 and 20 (S)-ginsenoside-Rg2, were well separated at 14.5 min and 13.6 min, respectively. The linear ranges of the standard curves were 2.0-250 microg/ml. The intra- and inter-day precision (R.S.D.) were 相似文献   

9.
A simple and sensitive liquid chromatography-tandem mass spectrometry (LC/MS/MS) method to determine the enantiomers of the muscle relaxant baclofen in human plasma and cerebrospinal fluid (CSF) has been developed. A commercially available ultrafiltration membrane is used to prepare the sample. A chiral CROWNPAK CR(+) stationary phase column is then used to perform complete resolution of the S(+)- and R(-)-enantiomers of baclofen. This method was used to analyze human plasma and CSF spiked with baclofen, and the calibration curves for both biologic samples were linear over a concentration range of 0.15-150 ng enantiomer/ml. The lower limit of quantification was 0.15 ng enantiomer/ml in both fluids. Finally, the method was tested with an artificial CSF as an alternative to authentic human CSF. The results showed that no matrix effects and no interfering peaks were observed using this artificial CSF.  相似文献   

10.
E-6087 is a nonsteroidal anti-inflammatory compound that selectively inhibits cyclooxygenase-2. Because E-6087 has a chiral center, this compound is a racemic mixture of two stereoisomers, (+)-(R)-E-6087 (E-6231) and (-)-(S)-E-6087 (E-6232). A normal-phase liquid-chromatographic method for the enantioselective determination of E-6087 in human plasma was developed and validated. The samples were extracted using solid-phase extraction cartridges containing C(18) sorbent, and the extracts were redissolved in absolute ethanol and injected into the chromatographic system. The enantiomeric separation was achieved on a chiral stationary-phase column of derivatized amylose, and the enantiomers were quantified by fluorescence detection. The method was validated for drug concentrations ranging from 5 to 400 ng/ml for both enantiomers. No peaks interfering with the quantification of enantiomers were observed. The limit of quantification was 5 ng/ml, with precision expressed as a coefficient of variation lower than 10.6% and accuracy expressed as relative error lower than 12.2%. The utility of this method was demonstrated by analysis of plasma samples from healthy volunteers given an oral dose of rac-E-6087. Peak plasma levels of E-6231 were higher than levels obtained for E-6232. Results were consistent with those obtained with a conventional reversed-phase method used for determination of the racemic compound.  相似文献   

11.
A selective chiral high performance liquid chromatographic (HPLC) method was developed and validated to separate and quantify the enantiomers of a novel anticonvulsant agent, N-(4-chlorophenyl)-1-(4-pyridyl)ethylamine (AAP-Cl), in rat plasma. After extraction of the plasma samples with ethyl acetate, the separation was accomplished by an HPLC system consisting of a Chirex chiral column (250 mm x 4.6 mm i.d.) and a mobile phase of hexane:ethanol:tetrahydrofuran (280:20:40 (v/v)) containing trifluroacetic acid (0.3% (v/v)) and triethylamine (0.018% (v/v)) at a flow rate of 0.8 ml/min with UV detection. Male Sprague-Dawley rats were given (+)-AAP-Cl (10 and 20 mg/kg), (-)-AAP-Cl (10 mg/kg) or the racemic mixture (20 mg/kg) by i.v. bolus injection and serial blood samples were collected at different times after drug administration. (+)-AAP-Cl and (-)-AAP-Cl were separated with a resolution factor, Rs, of at least 1.4, and a separation factor, alpha, greater than 1.09. Linear calibration curves were obtained over the concentration range of 0.5-30 microg/ml in plasma for both (+)-AAP-Cl and (-)-AAP-Cl (R2 > or = 0.996) with a limit of quantitation of 100 ng/ml and the recovery was greater than 80% for both enantiomers. The accuracy and precision for both enantiomers ranged from 96 to 102% (+/-0.2-7%) at upper and lower concentrations. The plasma concentration-time profiles of the enantiomers of AAP-Cl were best described by a two-compartment open model with a mean terminal half-life of about 5h, volume of distribution at steady state of 3 l/kg and clearance of about 0.6l/(hkg) in rats. There was no significant difference between the pharmacokinetic parameters of (+)-AAP-Cl and (-)-AAP-Cl, suggesting that the disposition of AAP-Cl in rats is not enantioselective. In addition, no chiral inversion of (+)-AAP-Cl to (-)-AAP-Cl or vice versa was observed. The results of this investigation have shed some light on the mechanism of action and disposition of AAP-Cl in rats.  相似文献   

12.
Oh JW  Trung TQ  Sin KS  Kang JS  Kim KH 《Chirality》2007,19(7):528-535
A coupled achiral-chiral high performance liquid chromatographic method was developed and fully validated for the determination of bevantolol enantiomers, (-)-(S)-bevantolol and (+)-(R)-bevantolol, in human plasma. Plasma samples were prepared by solid phase extraction with Sep-Pak Plus C18 cartridges followed by HPLC. Bevantolol enantiomers and (+)-(R)-Propranolol as internal standard (IS) were preseparated from interfering components in plasma on a Phenomenex silica column and bevantolol enantiomers and IS were resolved and determined on a Chiralcel OJ-H chiral stationary phase. The two columns were connected by a switching valve equipped with silica precolumn. The Precolumn was used to concentrate bevantolol in the eluent from the achiral column before back flushing onto chiral phase. A detailed validation of the method was performed accordingly to FDA guidelines. For each enantiomer the assay was linear between 20 and 1600 ng/ml. The quantification limits of both bevantolol enantiomers were 20 ng/ml. The intraday variation was between 1.07 and 12.64% in relation to the measured concentration and the interday variation was 0.91 and 11.79%. The method has been applied to the determination of (-)-(S)- and (+)-(R)-bevantolol in plasma from healthy volunteers dosed with racemic bevantolol hydrochloride.  相似文献   

13.
A sensitive and simple method was developed for determination of the enantiomers of azelnidipine, (R)-(-)-azelnidipine and (S)-(+)-azelnidipine, in human plasma using chiral liquid chromatography with positive ion atmospheric pressure chemical ionization tandem mass spectrometry. Plasma samples spiked with stable isotope-labeled azelnidipine, [(2)H(6)]-azelnidipine, as an internal standard, were processed for analysis using a solid-phase extraction in a 96-well plate format. The azelnidipine enantiomers were separated on a chiral column containing alpha(1)-acid glycoprotein as a chiral selector under isocratic mobile phase conditions. Acquisition of mass spectrometric data was performed in multiple reaction monitoring mode, monitoring the transitions from m/z 583-->167 for (R)-(-)-azelnidipine and (S)-(+)-azelnidipine, and from m/z 589-->167 for [(2)H(6)]-azelnidipine. The standard curve was linear over the studied range (0.05-20 ng/mL), with r(2)>0.997 using weighted (1/x(2)) quadratic regression, and the chromatographic run time was 5.0 min/injection. The intra- and inter-assay precision (coefficient of variation), calculated from the assay data of the quality control samples, was 1.2-8.2% and 2.4-5.8% for (R)-(-)-azelnidipine and (S)-(+)-azelnidipine, respectively. The accuracy was 101.2-117.0% for (R)-(-)-azelnidipine and 100.0-107.0% for (S)-(+)-azelnidipine. The overall recoveries for (R)-(-)-azelnidipine and (S)-(+)-azelnidipine were 71.4-79.7% and 71.7-84.2%, respectively. The lower limit of quantification for both enantiomers was 0.05 ng/mL using 1.0 mL of plasma. All the analytes showed acceptable short-term, long-term, auto-sampler and stock solution stability. Furthermore, the method described above was used to separately measure the concentrations of the azelnidipine enantiomers in plasma samples collected from healthy subjects who had received a single oral dose of 16 mg of azelnidipine.  相似文献   

14.
A liquid chromatography-tandem mass spectrometry (LC/MS/MS) method was developed and validated for the quantitation of (R)-, (S)-fluoxetine, and (R)-, (S)-norfluoxetine in ovine plasma. The analytes were extracted from ovine plasma at a basic pH using a single-step liquid-liquid extraction with methyl-tert-butyl ether. Chromatographic separation of all enantiomers was achieved using an AGP-chiral column with a run time of 10 min. (R)-, (S)-fluoxetine, and (R)-, (S)-norfluoxetine were quantitated at the total ion current (TIC) of multiple reaction monitoring (MRM) transitions of m/z 310.2→44.1, m/z 310.2→147.7 for (R)-, (S)-fluoxetine, and m/z 296.2→30.3, m/z 296.2→133.9 for (R)-, (S)-norfluoxetine. This method was validated for accuracy, precision, linearity, range, limit of quantitation (LOQ), selectivity, recovery, dilution integrity, matrix effect, and evaluation of carry-over. Observed accuracy ranges were as follows: (R)-fluoxetine -8.82 to 3.75%; (S)-fluoxetine -10.8 to 1.46%; (R)-norfluoxetine -7.50 to 0.37% and (S)-norfluoxetine -8.77% to -1.33%. Observed precision ranges were as follows: (R)-fluoxetine 5.29-11.5%; (S)-fluoxetine 3.91-11.1%; (R)-norfluoxetine 4.32-7.67% and (S)-norfluoxetine -8.77% to -1.33%. The calibration curves were weighted (1/X(2), n=4) and observed to be linear for all analytes with the following r(2) values: (R)-fluoxetine ≥ 0.997; (S)-fluoxetine ≥ 0.996; (R)-norfluoxetine ≥ 0.989 and (S)-norfluoxetine ≥ 0.994. The analytical range of the method was 1-500 ng/ml with an LOQ of 1 ng/ml for all analytes, using a sample volume of 300 μL.  相似文献   

15.
The method presented here is a high-performance liquid chromatography (HPLC)-UV detection method for the determination of baclofen R-(-)- and S-(+)-enantiomers in human plasma using a chiral separation technique. Baclofen enantiomers were extracted from human plasma with a reversed-phase solid-phase extraction (SPE) cartridge. The extract was then injected onto a HPLC system with a UV detection system set at 220 nm. The separation was achieved by using a 150x4.6 mm, 5 microm Phenomenex chirex 3216 chiral column with a mobile phase consisting of 0.4 mM CuSO(4) in acetonitrile-20 mM sodium acetate (17:83). The calibration curves were linear for both R-(-)- and S-(+)-enantiomers of baclofen in the concentration range of 20-5000 ng/ml. The average regressions were 0.9980 and 0.9991 for R-(-)- and S-(+)-baclofen, respectively. Inter-day precision was 3.3-5.2% for R-(-)-baclofen and 3.5-3.9% for S-(+)-baclofen at a concentration range of 60-4000 ng/ml. Intra-day precisions were 0.6-4.4 and 0.5-3.5% for R-(-)-baclofen and S-(+)-baclofen, respectively. The average extraction recovery was 81.6% for R-(-)-baclofen, 83.0% for S-(+)-baclofen and 94.0% for the internal standard (p-aminobenzoic acid). The limit of quantitation for both R-(-)- and S-(+)-baclofen in human plasma was 20 ng/ml. The method is simple and easy to operate with accuracy and reproducibility and it is suitable for pharmacokinetic studies.  相似文献   

16.
It has been proposed that the chiral inversion of the 2-arylpropionic acids is due to the stereospecific formation of the (-)-R-profenyl-CoA thioesters which are putative intermediates in the inversion. Accordingly, amino acid conjugation, for which the CoA thioesters are obligate intermediates, should be restricted to those optical forms which give rise to the (-)-R-profenyl-CoA, i.e., the racemates and the (-)-(R)-isomers. We have examined this problem in dogs with respect to 2-phenylpropionic acid(2-PPA). Regardless of the optical configuration of 2-phenylpropionic acid administered, the glycine conjugate was the major urinary metabolite and this was shown to be exclusively the (+)-(S)-enantiomer by chiral HPLC. Both (-)-(R)- and (+)-(S)-2-phenylpropionic acid were present in plasma after the administration of either antipode, and further evidence of the chiral inversion of both enantiomers was provided by the presence of some 25% of the opposite enantiomer in the free 2-phenylpropionic acid and its glucuronide excreted in urine after administration of (-)-(R)- and (+)-(S)-2-phenylpropionic acid. The (+)-(S)-enantiomer underwent chiral inversion to the (-)-(R)-antipode when incubated with dog hepatocytes. These data suggests that both enantiomers of 2-phenylpropionic acid are substrates for canine hepatic acyl CoA ligase(s) and thus undergo chiral inversion, but that the CoA thioester of only (+)-(S)-2-phenylpropionic acid is a substrate for the glycine N-acyl transferase. These studies are presently being extended to the structure and species specificity of the reverse inversion and amino acid conjugation of profen NSAIDs.  相似文献   

17.
A method for the determination of the R-(+) and S-(−) enantiomers of propranolol in blood was developed. After extraction with heptane—isopentanol and derivatization with (+)-1-(9-fluorenyl)ethyl chloroformate, excess reagent was removed using solid-phase extraction. The enantiomers were separated on an achiral, reversed-phase, radially compressed column, and detected by fluorescence with excitation and emission wavelengths of 260 and 340 nm, respectively. The limit of quantification was 0.5 ng/ml. This method was used for pharmacokinetic analysis of propranolol enantiomers after administration of immediate-release (80 mg) or sustained-release (160 mg) racemic propranolol.  相似文献   

18.
This article describes the enantioselective analysis of cyclophosphamide (CPA) in human plasma using LC-MS/MS. CPA enantiomers were extracted from plasma using a mixture of ethyl acetate and chloroform (75:25, v/v). The enantiomers were separated on a Chiralcel(R) OD-R column, with the mobile phase consisting of a mixture of acetonitrile and water (75:25, v/v) plus 0.2% formic acid. The protonated ions and their respective product ions were monitored using two functions, 261 > 141 for CPA enantiomers and 189 > 104 for the internal standard (antipyrine). Recovery rates were higher than 95% and the quantification limit was 2.5-ng/ml plasma for both enantiomers. The coefficients of variation and the relative errors obtained for the validation of intra- and interassay precision and accuracy were less than 10%. The method was applied for the investigation of the enantioselective pharmacokinetics of CPA in a lupus nephritis patient treated with 1 g CPA infused over 2 h and in a breast cancer patient treated with 0.9 g infused over 1 h. No stereoselectivity in the pharmacokinetic parameters was observed for either patient. Clearance values of 2.63 and 2.93 l/h and of 3.36 and 3.61 l/h for (-)-(S) and (+)-(R)-CPA were obtained for the breast cancer and lupus nephritis patient, respectively.  相似文献   

19.
Oxcarbazepine is a second‐generation antiepileptic drug indicated as monotherapy or adjunctive therapy in the treatment of partial seizures or generalized tonic–clonic seizures in adults and children. It undergoes rapid presystemic reduction with formation of the active metabolite 10‐hydroxycarbazepine (MHD), which has a chiral center at position 10, with the enantiomers (S)‐(+)‐ and R‐(?)‐MHD showing similar antiepileptic effects. This study presents the development and validation of a method of sequential analysis of oxcarbazepine and MHD enantiomers in plasma using liquid chromatography with tandem mass spectrometry (LC‐MS/MS). Aliquots of 100 μL of plasma were extracted with a mixture of methyl tert‐butyl ether: dichloromethane (2:1). The separation of oxcarbazepine and the MHD enantiomers was obtained on a chiral phase Chiralcel OD‐H column, using a mixture of hexane:ethanol:isopropanol (80:15:5, v/v/v) as mobile phase at a flow rate of 1.3 mL/min with a split ratio of 1:5, and quantification was performed by LC‐MS/MS. The limit of quantification was 12.5 ng oxcarbazepine and 31.25 ng of each MHD enantiomer/mL of plasma. The method was applied in the study of kinetic disposition of oxcarbazepine and the MHD enantiomers in the steady state after oral administration of 300 mg/12 h oxcarbazepine in a healthy volunteer. The maximum plasma concentration of oxcarbazepine was 1.2 µg/mL at 0.75 h. The kinetic disposition of MHD is enantioselective, with a higher proportion of the S‐(+)‐MHD enantiomer compared to R‐(?)‐MHD and an AUC0‐12 S‐(+)/R‐(?) ratio of 5.44. Chirality 25:897–903, 2013. © 2013 Wiley Periodicals, Inc.  相似文献   

20.
A sensitive and stereospecific liquid chromatography‐tandem mass spectrometry method for the quantitative determination of TWo8 enantiomers ((2RS)‐1‐(7‐methoxy‐1H‐indol‐4‐yloxy)‐3‐(2‐(2‐methoxyphenoxy)ethylamino)‐propan‐2‐ol) was developed and validated in rat serum and some tissues. Racemic TWo8 is a new chemical entity, and it has been shown to possess pharmacological activity in vivo. The assay involved the diastereomeric derivatization of racemic TWo8 with 2,3,4,6‐tetra‐O‐acetyl‐beta‐glucopyranosyl isothiocyanate. The TWo8 diastereoisomers quantification was performed on a triple quadrupole mass spectrometer employing an electrospray ionization technique. The precursor to the product ion transition for TWo8 derivatives and for the internal standard (carbamazepine) was m/z 776.4 → 387.2 and 237.4 → 194.4, respectively. The assay was validated with a linear range of 10–2000 ng/ml of racemic TWo8. The inter‐day precisions for (?)‐(S)‐TWo8 and (+)‐(R)‐TWo8 were 2.1% to 14.9% and 1.3% to 14.8%, respectively. The inter‐day accuracy for (?)‐(S)‐TWo8 and (+)‐(R)‐TWo8 was within 86% to 114% and 91% to 114%, respectively. A pilot pharmacokinetic study of this new β‐adrenolytic compound has shown that (?)‐(S)‐TWo8 is eliminated faster than its antipode. The terminal half‐lives of (?)‐(S)‐TWo8 and (+)‐(R)‐TWo8 were 3.2 and 3.9 h, respectively. The compound distribution into different organs, evaluated in tissue homogenate samples following TWo8 intravenous administration, showed an enantioselective penetration of TWo8 enantiomers in the liver (p < 0.03), in the kidney (p < 0.001), and in the lungs (p < 0.05). The developed method using liquid chromatography‐tandem mass spectrometry method with electrospray ionization could be employed for quantitative determination of compounds with similar structure. Chirality 24:591–599, 2012. © 2012 Wiley Periodicals, Inc.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号