首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
AIMS: Developing and evaluating a rapid real-time polymerase chain reaction (PCR) method for the identification of Escherichia coli O157:H7 in cattle and dairy wastewater samples produced from mozzarella cheese factories, without pre-enrichment step before DNA extraction. METHODS AND RESULTS: Wastewater samples were collected from a dairy farm producing mozzarella cheese and located in Puglia (south of Italy). Plate count and other microbial assays were performed 1 h after sampling. Wastewater samples were artificially inoculated with 10(4), 10(7) and 10(8) cells ml(-1) of E. coli O157:H7, strain EDL933. PCR protocols for stx1, stx2 and eae genes were first tested on pure DNA extracted from type strains, in order to optimize the amplification conditions and reagent concentration before real-time PCR experiments. Three specific fragments of ca 106, 150 and 200 bp corresponding to genes eae, stx1 and stx2, respectively, were obtained. Real-time PCR experiments were performed with DNA extracted from dairy and manure wastewater samples inoculated with 10(4), 10(7) and 10(8) colony-forming units (CFU) ml(-1) of E. coli O157:H7 strain EDL 933. The sensitivity limit of the assay was 10(-1) pg microl(-1) for eae, stx2 and 16SrRNA, and 1 pg microl(-1) for stx1 gene respectively. CONCLUSIONS: A real-time PCR protocol has been developed and used in order to identify potential pathogens in dairy wastewater, in which previous methods (including standard PCR) failed to work. SIGNIFICANCE AND IMPACT OF THE STUDY: Cattle and dairy wastewater samples produced from mozzarella cheese factories may harbour verocytotoxin-producing E. coli. The availability of rapid and sensitive molecular methods may be useful to monitor the persistence of verocytotoxin-producing E. coli in general and to assess the effectiveness of wastewater treatments.  相似文献   

2.
We investigated three probe design strategies used in quantitative polymerase chain reaction (PCR) for sensitivity in detection of the PCR amplicon. A plasmid with a 120-bp insert served as the DNA template. The probes were TaqMan, conventional molecular beacon (MB), and shared-stem molecular beacon (ATssMB and GCssMB). A shared-stem beacon probe combines the properties of a TaqMan probe and a conventional molecular beacon. It was found that the overall sensitivities for the four PCR probes are in the order of MB>ATssMB>GCssMB>TaqMan. The fluorescence quantum yield measurements indicate that incomplete or partial enzymatic cleavage catalyzed by Taq polymerase is the likely cause of the low sensitivities of two shared-stem beacons when compared with the conventional beacon probe. A high-fluorescence background associated with the current TaqMan probe sequence contributes to the relatively low detection sensitivity and signal-to-background ratio. The study points out that the nucleotide environment surrounding the reporting fluorophore can strongly affect the probe performance in real-time PCR.  相似文献   

3.
A multiplex real-time PCR method to simultaneously detect the stx1 and stx2 genes of Shiga toxin-producing Escherichia coli and a unique conserved single-nucleotide polymorphism in the E. coli O157:H7/H- uidA gene has been developed. There is more than 98.6% sensitivity and 100% specificity for all three gene targets based on a panel of 138 isolates. The PCR efficiencies were >/= 1.89, and as few as 6 CFU/reaction could be detected.  相似文献   

4.
Enterohemorrhagic Escherichia coli (EHEC) are a physiologically, immunologically and genetically diverse collection of strains that pose a serious water-borne threat to human health. Consequently, immunological and PCR assays have been developed for the rapid, sensitive detection of presumptive EHEC. However, the ability of these assays to consistently detect presumptive EHEC while excluding closely related non-EHEC strains has not been documented. We conducted a 30-month monitoring study of a major metropolitan watershed. Surface water samples were analyzed using an immunological assay for E. coli O157 (the predominant strain worldwide) and a multiplex PCR assay for the virulence genes stx(1), stx(2) and eae. The mean frequency of water samples positive for the presence of E. coli O157, stx(1) or stx(2) genes, or the eae gene was 50%, 26% and 96%, respectively. Quantitative analysis of selected enriched water samples indicated that even in samples positive for E. coli O157 cells, stx(1)/stx(2) genes, and the eae gene, the concentrations were rarely comparable. Seventeen E. coli O157 strains were isolated, however, none were EHEC. These data indicate the presence of multiple strains similar to EHEC but less pathogenic. These findings have important ramifications for the rapid detection of presumptive EHEC; namely, that current immunological or PCR assays cannot reliably identify water-borne EHEC strains.  相似文献   

5.
Despite the great importance of Aureobasidium pullulans in biotechnology, the fungus had emerged as an opportunistic human pathogen, especially among immunocompromised patients. Clinical detection of this rare human fungal pathogen presently relies on morphology diagnosis which may be misleading. Thus, a sensitive and accurate quantitative molecular assay for A. pullulans remains lacking. In this study, we presented the microscopy observations of A. pullulans that reveals the phenotypic plasticity of the fungus. A. pullulans-specific primers and molecular beacon probes were designed based on the fungal 18S ribosomal RNA (rRNA) gene. Comparison of two probes with varied quencher chemistry, namely BHQ-1 and Tamra, revealed high amplification efficiency of 104% and 108%, respectively. The optimized quantitative real-time PCR (qPCR) assays could detect and quantify up to 1 pg concentration of A. pullulans DNA. Both assays displayed satisfactory performance parameters at fast thermal cycling mode. The molecular assay has great potential as a molecular diagnosis tool for early detection of fungal infection caused by A. pullulans, which merits future study in clinical diagnosis.  相似文献   

6.
van Schie RC  Marras SA  Conroy JM  Nowak NJ  Catanese JJ  de Jong PJ 《BioTechniques》2000,29(6):1296-300, 1302-4, 1306 passim
Conventional, high-throughput PCR analysis of common elements utilizing numerous primer sets and template DNA requires multiple rounds of PCR to ensure optimal conditions. Laborious gel electrophoresis and staining is then necessary to visualize amplification products. We propose novel multicolor molecular beacons, to establish a high-throughput, PCR-based sequence tagged site (STS) detection system that swiftly and accurately confirms marker content in template containing common repeat elements. A simple, one-tube, real-time PCR assay system was developed to specifically detect regions containing CA and GATA repeats. Ninety-six samples can be confirmed for marker content in a closed-tube format in 3 h, eliminating product confirmation on agarose gels and avoiding crossover contamination. Multiple STSs can be detected simultaneously in the same reaction tube by utilizing molecular beacons labeled with multicolor fluorophores. Template DNA from 260 RPCI-11 bacterial artificial chromosome (BAC) clones was examined for the presence of CA and/or GATA repeats using molecular beacon PCR and compared with conventional PCR results of the same clones. Of the 205 clones containing CA and GATA repeats, we were able to identify 129 clones (CA, n = 99; GATA, n = 30) by using molecular beacons and only 121 clones (CA, n = 92; GATA, n = 29) by conventional PCR amplification. As anticipated, 55 clones that contained sequences other than CA or GATA failed molecular beacon detection. Molecular beacon PCR, employing beacons specific for tandem repeat elements, provides a fast, accurate, and sensitive multiplex detection assay that will expedite verification of marker content in a multitude of template containing these repeats.  相似文献   

7.
WSSV和IHHNV二重实时荧光PCR检测方法的建立   总被引:6,自引:2,他引:4  
根据基因库中对虾白斑综合征病毒WSSV(AF369029)和传染性皮下及造血器官坏死病毒IHHNV(AF218226)基因序列,设计了WSSV和IHHNV的两对特异性引物和两条用不同荧光基团标记的TaqMan探针。对反应条件和试剂浓度进行优化,建立了能够同时检测WSSV和IHHNV的二重实时荧光PCR方法。该方法特异性好,对WSSV和IHHNV的检测敏感性分别达到2和20个模板拷贝数;此外抗干扰能力强,对WSSV和IHHNV不同模板浓度进行组合,仍可有效地同时检测这二个病毒。对保存的30份经常规PCR检测仅为WSSV或IHHNV阳性的样品进行二重实时荧光PCR检测,结果都为阳性,其中1份为WSSV和IHHNV混合感染。本研究建立的二重实时荧光PCR方法用于WSSV和IHHNV的检测具有特异、敏感、快速、定量等优点。  相似文献   

8.
Abstract

Buccal cell samples are increasingly used in epidemiological studies as a source of genomic DNA. The accurate and precise quantitation of human DNA is critical for the optimal use of these samples. However, it is complicated by the presence of bacterial DNA and wide inter-individual variation in DNA concentration from buccal cell collections. The paper evaluated the use of ultraviolet light (UV) spectroscopy, Höechst (H33258) and PicoGreen? as measures of total DNA, and real-time quantitative polymerase chain reaction (PCR) as a measure of human amplifiable DNA in buccal samples. Using serially diluted white blood cell DNA samples (at a concentration range of 300 to 0.5?ng µl?1), UV spectroscopy showed the largest bias, followed by Höechst, especially for low concentrations. PicoGreen and real-time PCR provided the most accurate and precise estimates across the range of concentrations evaluated, although an increase in bias with decreasing concentrations was observed. The ratio of real-time PCR to PicoGreen provided a reasonable estimate of the percentage of human DNA in samples containing known mixtures of human and bacterial DNA. Quantification of buccal DNA from samples collected in a breast cancer case-control study by PicoGreen and real-time PCR indicated that cytobrush and mouthwash DNA samples contain similar percentages of human amplifiable DNA. Real-time PCR is recommended for the quantification of buccal cell DNA in epidemiological studies since it provides precise estimates of human amplifiable DNA across the wide range of DNA concentrations commonly observed in buccal cell DNA samples.  相似文献   

9.
A assay was developed to detect the level of contaminating male fertile rapeseeds within a population of male sterile Ogu-INRA seeds, based on PCR amplification of DNA and fluorescence technology. A molecular beacon was constructed to recognize a specific sequence of the male fertile plant. However, this sequence was also present in the male sterile plant at a very low concentration because of the recombinant structure of the Ogu-INRA mitochondrial genome. Conditions for quantitative PCR were found to take into account this biological data in order to develop an effective test. A 1% contamination can be detected with the naked eye with an ultraviolet light table or by use of a spectrofluorometer. The sensitivity of this method is dependent upon the molecular beacon concentration.  相似文献   

10.
粪便中肠球菌SYBR GreenI荧光定量PCR检测方法的建立   总被引:2,自引:0,他引:2  
目的利用SYBR GreenI荧光定量PCR方法,建立肠球菌实时荧光PCR检测方法,并初步应用于粪便中肠球菌的检测。方法根据GenBank发表的肠球菌23S rRNA基因序列的保守区域设计合成特异性的引物;利用构建的质粒标准品绘制两种标准曲线,构建基因拷贝数、细菌数为分析指标的定量分析模型并初步应用于粪便标本的检测分析。结果所建立的SYBR GreenI荧光定量PCR方法检测灵敏度可达7个拷贝数/reaction。粪便样本根据实时荧光定量PCR方法所得的理论数值与培养菌值之间差异无显著性(P>0.05)。非炎性腹泻标本中菌数与健康成人标本中菌数差异无显著性(P>0.05)。灵敏度曲线所得的数值大于菌数标准曲线,可能由于DNA提取过程中存在部分的损失。检测粪便标本结果显示SYBR GreenI荧光定量PCR方法较平板计数法敏感、快捷、简便。结论本研究建立了一种灵敏、特异、简便易行的肠球菌定量检测方法。  相似文献   

11.
A multiplex real-time PCR method to simultaneously detect the stx1 and stx2 genes of Shiga toxin-producing Escherichia coli and a unique conserved single-nucleotide polymorphism in the E. coli O157:H7/H uidA gene has been developed. There is more than 98.6% sensitivity and 100% specificity for all three gene targets based on a panel of 138 isolates. The PCR efficiencies were ≥1.89, and as few as 6 CFU/reaction could be detected.  相似文献   

12.
13.
AIMS: To evaluate the occurrence and abundance of phages that carry the stx(1) and stx(2) gene in water samples of different quality. METHODS AND RESULTS: Phages growing on the Shiga toxin-negative Escherichia coli O157:H7 (ATCC 43,888) strain were enumerated by a plaque assay in concentrated raw and treated waste water samples and river water samples. Plaques were investigated for the presence of stx(1) and stx(2) genes by a multiplex/nested PCR procedure. An overall number of 805 plaques were tested for the presence of stx-carrying phages. Stx genes could be demonstrated in 2% (stx(1)) and 16% (stx(2)) of the plaques. Stx-phages were eliminated with approximately the same efficiency in comparison with somatic coliphages during the waste water treatment process. CONCLUSIONS: Due to the low numbers of phages carrying the stx genes 1 and 2 in treated waste water and river water, the dilution and inactivation of host bacteria and the unsuitable conditions for the transduction of host organisms in aquatic environments, it is difficult to derive from the data the direct evidence for a public health problem. SIGNIFICANCE AND IMPACT OF THE STUDY: The results show the quantitative occurrence of stx-carrying phages in waste and river water and confirm the frequent circulation of these viruses in the aquatic environment.  相似文献   

14.
由于分子信标具有结构简单,灵敏度高及反应迅速等优点,因此,利用分子信标进行数学问题的求解将成为可能.通过对分子信标的计算模型进行详细的介绍,并对分子信标的计算模型的研究思路进行了展望,据此思路,可以建立多种组合优化问题及逻辑门的分子信标计算模型.  相似文献   

15.
16.
实时荧光定量PCR技术及其应用   总被引:11,自引:0,他引:11  
定量PCR的问世是继定性PCR(即常规PCR)后分子生物学方法学研究的一大飞跃,实现了对核酸信息量的分析比较,为疾病的诊断和治疗提供了更多、更有效的基因水平信息。本文介绍实时荧光定量PCR技术及其在兽医领域中的应用,包括近年来研究和应用较多的几种定量PCR技术。  相似文献   

17.
为建立高效快速的PRRSV NADC30-Like毒株荧光定量PCR(SYBR Green real-time PCR)检测方法,根据NADC30毒株Nsp2基因保守序列设计特异性引物,通过优化确定最佳反应条件,并进行灵敏度、特异性、重复性实验以及临床样品的检测。结果显示,标准品在10~7 copies/μL到10~2 copies/μL浓度范围内具有良好的线性关系,最低检测浓度为2.25×10~1 copies/μL;该方法与HP-PRRSV、PCV、PEDV、TGEV、PRV、CSFV、PoRV无交叉反应,批内和批间的变异系数(CV)小于1.9%,在临床样品的检测中较普通PCR有更高的检出率。建立了PRRSV NADC30-Like毒株荧光定量PCR检测方法,具有敏感性高、特异性强、稳定性好、准确度高和检测快速等优点,可用于PRRSV NADC30-Like感染的早期诊断、样品的快速检测与定量分析。  相似文献   

18.
Aims:  To develop and evaluate a real-time PCR assay incorporating an internal amplification control (IAC) suitable for the screening of Shiga toxin (Stx)-producing Escherichia coli (STEC) in foods.
Methods and Results:  A competitive IAC was constructed and included in an stx -specific real-time PCR assay. Coupled to 18-h enrichment and automated DNA extraction, the assay could reliably detect the presence of STEC in minced meats inoculated at 10 CFU per 25 g. Its performance was evaluated on 415 minced beef and 112 raw milk cheese samples and compared with that of a PCR-ELISA method. Fifty-three minced meats and 31 cheeses were found stx -positive, giving 98·3% and 93·75% concordance, respectively, with the PCR-ELISA reference method.
Conclusions:  A highly sensitive stx -specific real-time PCR method including an IAC was developed, facilitating monitoring of false-negative results due to PCR inhibitors.
Significance and Impact of the Study:  Combined with automated DNA extraction, the stx -IAC real-time PCR assay represents a suitable method for rapid screening of STEC in foods.  相似文献   

19.
At least 10 million individuals worldwide are co-infected with immunodeficiency virus type 1 (HIV-1) and hepatitis C virus (HCV). These two viruses are transmitted most primarily by exposure to infected blood or blood products. Various nucleic acid assays have been developed for diagnostics and therapeutic monitoring of infections. In the present study, a multiplex real-time PCR assay for simultaneous detection of HCV and HIV-1 using molecular beacons were designed and validated. A well-conserved region in the HIV-1 pol gene and 5′NCR of HCV genome were used for primers and molecular beacon design. The analysis of scalar concentrations of the samples indicated that this multiplex procedure detects at least 1,000 copies/ml of HIV-1 and 100 copies/ml of HCV with linear reference curve (R 2 > 0.94). The results demonstrate that a specificity of 100 % and sensitivity of 96 % can be achieved. The analytical sensitivity study with BLAST software demonstrated that the primers do not attach to any other sequences except for that of HIV-1 or HCV. The primers and molecular beacon probes only detected HIV-1 and all major variants of HCV. This assay may represent an alternative rapid and relatively inexpensive screening method for detection of HIV-1/HCV co-infection especially in blood screening.  相似文献   

20.
Real-time multiplex polymerase chain reaction (PCR) with internal positive control (IPC) was developed for simultaneous detection of adenoviruses (AV), enteroviruses (EV) and hepatitis A virus (HAV). Primes and probes labeled with different fluorophores (FAM, R6G, ROX, and Cy5) and able to detect up to four viral RNAs (DNAs) with high specificity in a single tube in real-time PCR were designed. Sensitivity and specificity of the method was estimated using cultural strains of 8 serotypes of EV, 5 serotypes of AV and 2 clinical specimens containing HAV. Sensitivity of the method for detection of polioviruses types 1, 2, and 3 (Sabin vaccine strains) was 0.5--1 TCID50 per reaction mixture. Thirty clinical specimens were analyzed by the multiplex PCR with and without IPC, and by mono-specific PCR. Comparison of these methods with cultural one revealed results agreement in 86.7% in case of multiplex PCR with IPC and in 100% in case of multiplex PCR without IPC and mono-specific PCR. This method can be used for rapid diagnostics of enteric viral infections as well as for determination of viral contamination level of water. As intermediate results of the study the methods for quantitative assessment of HAV, AV, and EV nucleic acids were developed which are convenient tools for the control of antiviral therapy effectiveness.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号