首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
(R)- and (S)-Methyl 2-(phenoxy)propionate and their acids could be separated simultaneously by a Chiralcel OD or OK column, while (R)- and (S)-methyl 2-(4-chlorophenoxy)propionate and their acids were separated concurrently only by an OK column. This is a novel and facile way to measure the enantiomeric excesses of the remaining substrate and product in the reaction of enzymatic resolution; enantiomeric ratios could then be calculated.  相似文献   

2.
Besifloxacin is a unique chiral broad‐spectrum flouroquinolone used in the treatment of bacterial conjunctivitis. R‐form of besifloxacin hydrochloride shows higher antibacterial activity as compared to the S‐isomer. Therefore, it is necessary to establish chiral purity. To establish chiral purity a high‐performance liquid chromatography (HPLC) method for determination of R‐besifloxacin and S‐besifloxacin (BES impurity A) was developed and validated for in‐process quality control and stability studies. The analytical performance parameters such as linearity, precision, accuracy, specificity, limit of detection (LOD), and lower limit of quantification (LOQ) were determined according to International Council for Harmonization ICH Q2(R1) guidelines. HPLC separation was achieved on Chiralpak AD‐H (250 x 4.6 mm, 5 μm) column using n‐heptane: ethanol: ethylenediamine: acetic acid (800:200:0.5:0.5) (v/v/v/v) as the mobile phase in an isocratic elution. The eluents were monitored by UV/Visible detector at 290 nm. The resolution between S‐isomer and besifloxacin hydrochloride was more than 2.0. Based on a signal‐to‐noise ratio of 3 and 10 the LOD of besifloxacin was 0.30 μg/mL, while the LOQ was 0.90 μg/mL. The calibration curves were linear in the range of 0.9–7.5 μg/mL. Precision of the method was established within the acceptable range. The method was suitable for the quality control enantiomeric impurity in besifloxacin hydrochloride. Chirality 28:628–632, 2016. © 2016 Wiley Periodicals, Inc.  相似文献   

3.
A novel method was developed using capillary electrophoresis (CE) coupled with tris(2,2′‐bipyridyl)ruthenium(II) electrogenerated chemiluminescence (ECL) for highly sensitive detection of metformin hydrochloride (MH) derivatizatized with acetaldehyde. The precolumn derivatization of MH with acetaldehyde was performed in phosphate buffer solution (0.3 mol/L, pH 7.5) at room temperature for 120 min. The effects of acetaldehyde concentration, buffer pH, electrokinetic voltage and injection time were investigated. Under optimized detection conditions, the MH ECL detection sensitivity was more than 120 times that without derivatization. The linear concentration range for MH was 0.001–15.00 μg/mL (with a correlation coefficient of 0.9992). The detection limit was 0.31 ng/mL with a signal:noise ratio of 3. The recoveries of MH in human urine were in the range 98.50–99.72%. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

4.
Liu JH  Yu BY  Chen YJ 《Chirality》2008,20(1):51-53
A simple and reliable chiral HPLC method was developed for the determination of enantiomeric excess of a chiral dihydroxy intermediate for the chemoenzymatic synthesis of side chain of statin drugs. After evaluating different columns and conditions, the four stereoisomers of ethyl 3,5-dihydroxy-6-benzyloxy hexanoate were well resolved by a simple gradient elution on OD-RH column, and the enantiomeric excess of the desired 3R,5S-enantiomer was accurately measured. This study provides a simple, rapid, accurate, and reliable method to assess the enantiomeric quality of such important intermediates.  相似文献   

5.
The use of ortho‐phthalaldehyde (OPA) for the derivatization of amino acids (AA) is well known. It enables the separation of the derivatives on common reversed phase columns and improves the sensitivity with fluorescence detection. With the use of a chiral thiol an indirect enantioseparation of chiral amines and AAs is feasible. The major drawback of the OPA‐derivatization is the poor stability of the products. Here, a method with an in‐needle derivatization procedure is optimized to facilitate a quantitative conversion of the AA with OPA and the chiral thiols N‐acetyl‐L‐cysteine or N‐isobutyryl‐L‐cysteine, followed by a subsequent analysis, eluding the stability issue. Both enantiomers of a single AA were separated as OPA‐derivatives with a pentafluorophenyl column and a gradient program consisting of 50 mM sodium acetate buffer pH = 5.0 and acetonitrile. Fluorescence detection is commonly used to achieve sufficient sensitivity. In this study, the enantiomeric impurity of an AA can be detected indirectly with common UV spectrophotometric detection with a limit of quantitation of 0.04%. Seventeen different L‐AAs were tested and the amount of D‐AA for each individual AA was calculated by means of area normalization, which ranged from not detectable up to 4.29%. The recovery of the minor enantiomer of L‐ and D‐AA was demonstrated for three AAs at a 0.04% level and ranged between 92.3 and 113.3%, with the relative standard deviation between 1.7 and 8.2%.  相似文献   

6.
A high-performance liquid chromatography (HPLC) assay with fluorescence detection was developed for the determination of the polyamines putrescine, spermidine, spermine in samples of human spinal cord, cerebellum, cerebrospinal fluid (CSF), skeletal muscle, and muscle microdialysates without an extensive sample preparation. The precolumn derivatization was performed with 9-fluorenylmethyl chloroformate (FMOC), and the derivatizated polyamines were stable for at least 14 h at 4 degrees C. All polyamines were separated within 35 min. The method was checked for linearity, and mean correlation coefficient values of 0.995, 0.999, and 0.991 were achieved for putrescine, spermidine, and spermine, respectively. The within- and between-assay coefficient of variation percentages evaluated in standard solutions varied between 1.0 and 4.9% and between 1.3 and 6.9%, respectively. The corresponding values obtained in samples of human spinal cord were between 1.0 and 5.0% and between 0.6 and 5.8%. The values of the recovery, evaluated in spinal cord tissue, varied between 83.7 and 93.5%.  相似文献   

7.
Four 4-halogen-substituted phenylcarbamate derivatives of amylose were prepared and their chiral recognition abilities as chiral stationary phases (CSPs) for high-performance liquid chromatography (HPLC) were evaluated and compared with those of the corresponding cellulose derivatives. The amylose derivatives with fluoro, chloro, bromo, or iodo group at the four-position on the phenyl group were found to show higher chiral resolving ability than the corresponding cellulose derivatives. Among four amylose derivatives 4-fluoro- and 4-chlorophenylcarbamates showed an excellent chiral recognition ability. Especially, amylose tris(4-chlorophenylcarbamate) resolved (±)-1,2,2,2-tetraphenylethanol with a very high α value (α = 8.29). In order to obtain useful information concerning the chiral recognition mechanism of this resolution, we also performed enantioseparation of a variety of analogous racemic alcohols, and found that both the hydroxy and bulky triphenylmethyl groups of the racemate are essential for the effective chiral recognition. Chirality 9:63–68, 1997. © 1997 Wiley-Liss, Inc.  相似文献   

8.
Methods for the quantitative derivatization of amino acids with phenylisothiocyanate and for the separation and quantitation of the resulting phenylthiocarbamyl derivatives by reverse-phase high-performance liquid chromatography are described. Phenylthiocarbamylation of amino acids proceeds smoothly in 5 to 10 min at room temperature. Coupling solvents, reagent, and some byproducts are removed by rotary evaporation under high vacuum, and the phenylthiocarbamyl derivatives are dissolved in 0.05 M ammonium acetate, pH 6.8, for injection onto the octyl or octadecylsilyl reverse-phase column. Columns are equilibrated with the same solvent and the effluent stream is monitored continuously at 254 nm for detection of the amino acid derivatives. Elution of all of the phenylthiocarbamyl amino acids is achieved in about 30 min utilizing gradients of increasing concentrations of ammonium acetate and acetonitrile or methanol. This approach to amino acid analysis offers select advantages, both with respect to methods which employ reverse-phase separation of prederivatized samples and to the classical ion-exchange procedure. All amino acids, including proline, are converted quantitatively to phenylthiocarbamyl compounds and these are stable enough to eliminate any need for in-line derivatization. Furthermore, results comparable in sensitivity and precision to those obtained by state-of-the-art ion-exchange analyzers may be generated with equipment that need not be dedicated to a single application.  相似文献   

9.
A reversed-phase high-performance liquid chromatographic method for the detection of boronophenylalanine is described. Determination was obtained by precolumn reaction of o-phthalaldehyde with a mixture of standard amino acids containing boronophenylalanine and separating the corresponding o-phthalaldehyde derivatives, using a Kromasil C-18, 250 x 4.6 mm, 5-microm particle size column, a step gradient with two buffers, a flow rate of 1.2 ml/min, a column temperature of 23 degrees C, and fluorimetric detection (excitation and emission wavelengths of 330 and 430 nm, respectively). The use of such a method for assaying boronophenylalanine in biological samples was tested in neutralized perchloric acid blood and cerebral tissue extracts of rats treated with intracarotid administration of 300 mg/kg of body weight boronophenylalanine. Results of these experiments showed that the present HPLC method represents a valid alternative to currently available analytical techniques for assaying boronophenylalanine based on boron determination in terms of reproducibility, recovery, or sensitivity. Therefore, it is suggested that the present method may routinely be used in all preclinical and clinical studies in which quantification of circulating and tissue concentrations of boronophenylalanine is critical for the application of boron neutron capture therapy.  相似文献   

10.
A sensitive and selective HPLC method for the determination of the disaccharides of chondroitin sulfate in horse and dog plasma was validated. Chondroitin sulfate is degraded by chondroitinase ABC to three primary unsaturated disaccharides, (1) 2-acetamido-2-deoxy-3-O-(beta-D-gluco-4-enepyranosyluronic acid)-D-galactose, (2) 2-acetamido-2-deoxy-3-O-(beta-D-gluco-4-enepyranosyluronic acid)-4-O-sulfo-D-galactose, and (3) 2-acetamido-2-deoxy-3-O-(beta-D-gluco-4-enepyranosyluronic acid)-6-O-sulfo-D-galactose, when treated with chondroitinase. Plasma samples (0.5 ml) were treated with 50 mU of chondroitinase ABC in 50 microl of 1 mM sodium phosphate buffer (pH 7.0) at 37 degrees C for 6 h. The samples were extracted with 25% trifluoroacetic acid in ethanol. The resultant samples were derivatized with 1% dansylhydrazine in ethanol at 40 degrees C for 3 h. The chromatographic conditions consisted of fluorescence detection (excitation at 350 nm and emission at 530 nm), mu-Bondapack NH(2) (300 x 3.9 mm), and mobile phase of acetonitrile:100 mM acetate buffer, pH 5.6 (76:24), pumped at 1.0 ml/min. The standard curves for each chondroitin disaccharide showed linearity over the selected concentration range (r > or = 0.99). The intraday percentage relative standard deviation was < or =9.5% and the interday precision was < or =6.9% or less. The relative intraday and interday error ranged from -7.3 to 6.6% for each chondroitin disaccharide in the plasma. The extraction recovery was found to be in the range of 90-96%. The validated method accurately quantitated the disaccharides of chondroitin sulfate after administration to dogs and horses.  相似文献   

11.
Cellulose-tris (3,5-dimethylphenylcarbamate; CDMPC) was synthesized and coated on aminopropylsilica to prepare chiral stationary phase (CSP). Normal-phase high-performance liquid chromatography (HPLC) methods for the resolutions of five chiral triazole pesticides, diniconazole, tebuconazole, hexaconazole, triadimefon and flutriafol, on the CSP were developed. Several operating parameters such as mobile phase composition, modifier and column temperature were studied for the optimization of the resolutions. Better separations were achieved using 2% iso-butanol for diniconazole, 2% ethanol for tebuconazole, 2% iso-propanol for hexaconazole, 1% n-butanol for triadimefon and 2% n-propanol for flutriafol as modifiers in n-hexane at 0 degrees C with the resolution factors (Rs) of 1.62, 1.66, 2.46, 1.68 and 1.98, respectively. Low temperature was better for the resolutions. Validation of the methods included linearity and precision.  相似文献   

12.
D K Lloyd  D M Goodall 《Chirality》1989,1(4):251-264
Chiroptical detection for HPLC is particularly useful as a selective detection method for chiral molecules, and in enantiomeric purity determination with partial chiral separation or without chiral separation. The recent development of laser-based polarimeters with microdegree sensitivity has increased the applicability of optical rotation detection in HPLC. The detection limit of these instruments is submicrogram on-column for many chiral compounds in analytical HPLC. A variety of applications of the selective detection of optically active molecules are reviewed. The use of polarimetric detection with partial chiral separation is considered, both as an aid to method development and for enantiomeric purity determination. Finally applications to enantiomeric purity determination without chiral separation are reviewed, with the dual use of nonchirally selective and chiroptical detectors to determine the total amount and optical purity of the analyte. Determinations of chiral purity for samples of high enantiomeric excess are described, which with laser-based instrumentation may give accuracies of better than +/- 1% with sample loadings of 50 micrograms on an achiral column. Applications to the study of enantioselective reactions are also considered, with determination of enantiomeric excess in near-racemates to better than +/- 0.1%.  相似文献   

13.
Lin K  Xu C  Zhou S  Liu W  Gan J 《Chirality》2007,19(3):171-178
Chiral high-performance liquid chromatography (HPLC) is one of the most powerful tools to prepare enantiopure standards of chiral compounds. In this study, the enantiomeric separation of imidazolinone herbicides, i.e., imazethapyr, imazapyr, and imazaquin, was investigated using chiral HPLC. The enantioselectivity of Chiralpak AS, Chiralpak AD, Chiralcel OD, and Chiralcel OJ columns for the three analytes was compared under similar chromatographic conditions. Chiralcel OJ column showed the best chiral resolving capacity among the test columns. The resolved enantiomers were distinguished by their signs of circular dichroism detected at 275 nm and their structures confirmed with LC-mass spectrometric analysis. Factors affecting the chiral separation of imidazolinones on Chiralcel OJ column were characterized. Ethanol acted as a better polar modifier than the other alcohols including 2-propanol, 1-butanol, and 1-pentanol. Although the acidic modifier in the mobile phase did not influence chiral recognition, it was necessary for reducing the retention time of enantiomers and suppressing their peak tailing. Thermodynamic evaluation suggests that enantiomeric separation of imidazolinones on Chiralcel OJ column is an enthalpy-driven process from 10 to 40 degrees C. This study also shows that small amounts of pure enantiomers of imidazolinones may be obtained by using the analytical chiral HPLC approach.  相似文献   

14.
An optical resolution of the amide derivatives of ibuprofen and the carbamate-alkylester derivatives of the trans-alcohol metabolite of loxoprofen and an analogous compound, CS-670, was studied by chiral high-performance liquid chromatography (HPLC). The chiral columns SUMIPAX OA-4000 and OA-4100 were used to investigate the enantiomeric separation behavior of these derivatives using both reversed and normal mobile phases. A better separation factor (α) of the amide and the carbamate ester derivatives was obtained in the normal mobile phase than in the reversed mobile phase HPLC. In addition, the recognition mechanisms of both amide and carbamate ester enantiomers were investigated by 1H-nuclear magnetic resonance (NMR). It is suggested that the important driving forces for the enantiomeric separation are the formation of hydrogen bonding and the charge transfer complex between these derivatives and an active site of the chiral stationary phase. © 1995 Wiley-Liss, Inc.  相似文献   

15.
A method is described for the analysis of the neuroexcitatory amino acids, aspartate and glutamate, in human cerebrospinal fluid (CSF) by reverse-phase, high-performance liquid chromatography. Fluorescent isoindole derivatives of the amino acids were prepared by reacting the amino acids with ortho-phthalaldehyde in an automated, precolumn procedure. Chromatographic conditions were developed that resolve the isoindole derivatives of aspartate and glutamate from those of at least 10 unidentified components of CSF. Amino acids were reliably quantified in 5-microliter samples of CSF, and deproteinization of the specimens was not required. Furthermore, it was found that deproteinization by precipitation with strong acid can lead to artifactually high measurements of glutamate. The concentrations of free aspartate and glutamate in lumbar CSF from 15 neurologically normal children were 0.30 +/- 0.11 and 0.48 +/- 0.26 microM (mean +/- SD), respectively. The value for glutamate is considerably lower than has been reported in any previous study of human CSF.  相似文献   

16.
The development of high-performance liquid chromatography (HPLC) methods using derivatized amylose chiral stationary phases has permitted preparative enantioseparations of substituted 4-oxo-1,4-dihydroquinoline-3-carboxamide derivatives with satisfactory yields. These compounds constitute new potent selective agonists of the cannabinoid CB(2) receptor. Analytical enantioseparation methods using UV detection were validated to determine the enantiomeric purity of these compounds. Linear calibration curves in the range from 0.18 to 0.40 mM were obtained; repeatability, limits of detection (LOD), and quantification (LOQ) were determined: LOD varied, for the various solutes, from 0.5 to 1.2 μM. All the separated compounds were prepared with high enantiomeric purities superior to 99.3% Absolute configuration of the enantiomers was unequivocally established by single crystal X-ray diffraction method and correlated to the chiroptical properties of isolated enantiomers.  相似文献   

17.
Brewer BN  Zu C  Koscho ME 《Chirality》2005,17(8):456-463
The ability to use mixtures of deprotonated N-(3,5-dinitrobenzoyl)amino acids as chiral selectors for the determination of enantiomeric composition by electrospray ionization-mass spectrometry is demonstrated. For each experiment, two N-(3,5-dinitrobenzoyl)amino acids were chosen such that each would have opposite selectivity for the enantiomers of the analyte. Electrospray ionization-mass spectrometry, monitored in the negative ion mode, of solutions containing the two N-(3,5-dinitrobenzoyl)amino acids, sodium hydroxide, and the analyte, in a one-to-one mixture of methanol and water, afford peaks in the mass spectrum that correspond to the deprotonated 1:1 analyte-selector complexes. The ratio of the intensities of the complexes in the mass spectrum can be related to the enantiomeric composition of the analyte. Additionally, the sense and extent of chiral recognition is consistent with chromatographic observations, using chiral stationary phases derived from N-(3,5-dinitrobenzoyl)amino acids. Each analysis of enantiomeric composition requires less than 10 s to complete, indicating that this method has great potential for the development of fast-/high-throughput chiral analyses.  相似文献   

18.
In order to improve the sensitivity and stability of human blood samples containing WR-1065 (i.e., active metabolite of the cytoprotective agent amifostine), a high-performance liquid chromatographic method was developed and validated using fluorescent derivatization with ThioGlo3. Using a sample volume of only 100 microl, the method was specific, sensitive (limit of quantitation=10 nM in deproteinized blood or 20 nM in whole blood), accurate (error < or = 3.2%) and reproducible (CV < or = 8.7%). In addition, the stability of WR-1065 in deproteinized and derivatized blood samples was assured for at least four weeks at -20 degrees C. This method should be particularly valuable in translating the kinetic-dynamic relationship of WR-1065 in preclinical models to that in cancer patients.  相似文献   

19.
Malondialdehyde (MDA) is a biomarker for lipid peroxidation, and studies of sensitive and selective analytical methods for it are very important for pathological research. The aim of this work was to develop and validate a novel HPLC method for the quantification of MDA in biological fluids using rhodamine B hydrazide (RBH) as the derivatization reagent. After pretreatment and derivatization in acid medium at 50 °C for 40 min, the RBH-derivatized MDA was separated on a Kromasil C18 column at 25 °C and detected by a fluorescence detector at excitation wavelength of 560 nm and emission wavelength of 580 nm. The results showed linearity in the range of 0.8–1500.0 nM with a detection limit of 0.25 nM (S/N = 3). The recovery of MDA from plasma and urine was 91.50 to 99.20%, with a relative standard deviation range of 1.45 to 3.26%. In comparison to other methods reported for the determination of MDA, the proposed method showed superiority in simplicity, more sensitivity, shorter derivatization time, and less interference. The developed method was applied to quantification of MDA in human biological fluids collected from five volunteers with a concentration range of 24.62–245.00 nM.  相似文献   

20.
Vilanterol trifenatate is a novel chiral long‐acting β2‐agonist developed. Vilanterol combined with inhaled corticosteroids can treat COPD and asthma. A simple liquid chromatographic method is developed for the quantitative determination of R‐vilanterol and S‐vilanterol (impurity S). HPLC separation was achieved on Chiralpak ID (250 × 4.6 mm; particle size 5 μm) column using hexane‐ethanol‐ethanolamine (75:25:0.1, v/v/v) as mobile phase at a flow rate of 1.0 mL/min. The resolution is greater than 3.3. Ethanolamine in the mobile phase is vital to enhance chromatographic efficiency and resolution between the isomers. The method was validated with respect to accuracy, specificity, precision, LOD, LOQ, linearity, and robustness as ICH guidelines.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号