首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 203 毫秒
1.
Glabridin is a major flavonoid included specifically in licorice (Glycyrrhiza glabra L.), and has various physiological activities including antioxidant and anti-inflammatory effects. We have developed and validated an analytical method for determination of glabridin in human plasma by solid-phase extraction (SPE) and LC-MS/MS. Glabridin was extracted from plasma by SPE using a C8 cartridge and analyzed by LC-MS/MS using mefenamic acid as an internal standard (IS). The analyte were separated by a C18 column on LC, and monitored with a fragment ion of m/z 201 formed from a molecular ion of m/z 323 for glabridin and that of m/z 196 from m/z 240 for IS during negative ion mode with tandem MS detection. The lower limit of quantitation (LLOQ) of glabridin was 0.1 ng/mL in plasma, corresponding to 1.25 pg injected on-column. The calibration curves exhibited excellent linearity (r>0.997) between 0.1 and 50 ng/mL. Precision and accuracy were <17 and <+/-7% at LLOQ, and <11 and <+/-5% at other concentrations. Glabridin was recovered >90%, and was stable when kept at 10 degrees C for 72 h, at -20 degrees C until 12 weeks, and after three freeze-thaw cycles. This is the first report on determination of glabridin in body fluids by the selective, sensitive, and reproducible method.  相似文献   

2.
A highly sensitive and specific LC-MS method was developed and validated for the quantification of digoxin in human plasma and urine using d5-dihydrodigoxin as internal standard (IS). The assay procedure involved extraction of digoxin and IS from human plasma with chloroform-isopropanol (95:5, v/v). Chromatogrphic separation was achieved on a Spherisorb ODS2 column using a gradient mobile phase with 5 mmol/L ammonium acetate in water with 1% acetic acid and acetonitrile. The mass spectrometer was operated in the selected ion monitoring mode using the respective [M+K](+) ions, m/z 819.4 for digoxin and m/z 826.4 for IS. The method was proved to be accurate and precise at linearity range of 0.12-19.60 ng/mL in plasma with a correlation coefficient (r(2)) of >or=0.9968 and 1.2-196.0 ng/mL in urine. The limit of quantification achieved with this method was 0.12 ng/mL in plasma and 1.2 ng/mL in urine. The intra- and inter-assay precision and accuracy values were found to be within the assay variability limits as per the FDA guidelines. The developed assay method was successfully applied to a pharmacokinetic study in human volunteers following intravenous administration of digoxin.  相似文献   

3.
The elastin degradation products, desmosine (DES) and isodesmosine (IDES) are highly stable, cross-linking amino-acids that are unique to mature elastin. The excretion of DES/IDES in urine, in the free form and with associated peptide fragments, provides an indicator of lung damage in chronic obstructive pulmonary disease (COPD). A quantitative ion mobility-mass spectrometry (IM-MS) method has been developed for the analysis of free DES/IDES in urine with deuterated IDES as an internal standard. Resolution of DES/IDES isomers was achieved in less than five minutes using ultra performance liquid chromatography (UPLC) combined with ion pairing. The optimized UPLC-IM-MS method provided a linear dynamic range of 10-300 ng/mL and a limit of quantitation of 0.028 ng/mL for IDES and 0.03 ng/mL for DES (0.55 ng and 0.61 ng on column respectively). The method reproducibility (%RSD) was <4% for DES and IDES. The UPLC-IM-MS method was applied to the analysis of urine samples obtained from healthy volunteers and COPD patients. The DES/IDES concentrations in healthy and COPD urine showed an increase in DES (79%) and IDES (74%) in the COPD samples, relative to healthy controls. The incorporation of an IM separation prior to m/z measurement by MS was shown to reduce non-target ion responses from the bio-fluid matrix.  相似文献   

4.
Accurate determinations of 5-aminolevulinic acid (ALA) and porphobilinogen (PBG) in physiologic fluids are required for the diagnosis and therapeutic monitoring of acute porphyrias. Current colorimetric methods are insensitive and over-estimate ALA and PBG due to poor specificity, while LC-MS/MS methods increase sensitivity, but have limited matrices. An LC-MS/MS method was developed to simultaneously determine ALA and PBG concentrations in fluids or tissues which were solid phase extracted, butanol derivatized, and quantitated by selective reaction monitoring using (13)C(5), (15)N-ALA and 2,4-(13)C(2)-PBG internal standards. ALA was separated from interfering compounds on a reverse phase C8-column. For ALA and PBG, the matrix effects (87.3-105%) and process efficiencies (77.6-97.8% and 37.2-41.6%, respectively) were acceptable in plasma and urine matrices. The assay was highly sensitive for ALA and PBG (LLOQ=0.05 μM with 25 μL urine or 100 μL plasma), and required ~4 h from extraction to results. ALA and PBG accuracy ranged from 88.2 to 110% (n=10); intra- and inter-assay coefficients of variations were <10% for urine and plasma. In clinical applications, patients with mutation-confirmed acute porphyrias had normal to slightly increased urinary ALA and PBG levels when asymptomatic, and high levels during acute attacks, which decreased with hemin therapy. In AIP mice, baseline ALA and PBG levels in urine, plasma, and liver were increased after phenobarbital induction 28-/63-, 42-/266-, and 13-/316-fold, respectively. This LC-MS/MS method is rapid, specific, highly sensitive, accurate, and simultaneously measures ALA and PBG in urine, plasma, and tissues permitting porphyria clinical diagnoses, therapeutic monitoring, and research.  相似文献   

5.
Rimonabant is the first therapeutically relevant cannabinoid antagonist, licensed in Europe for treatment of obesity when a risk factor is associated. The objective of this study was to develop and validate a method for measurement of rimonabant in human plasma and hair using liquid chromatography coupled to mass spectrometry (LC-MS/MS). Rimonabant and AM-251 (internal standard) were extracted from 50muL of plasma or 10mg of hair using diethylether. Chromatography was performed on a 150mmx2.1mm C18 column using a mobile phase constituted of formate buffer/acetonitrile. Rimonabant was ionized by electrospray in positive mode, followed by detection with mass spectrometry. Data were collected either in full-scan MS or in full-scan MS/MS mode, selecting the ion m/z 463.1 for rimonabant and m/z 555.1 for IS. The most intense product ion of rimonabant (m/z 380.9) and IS (m/z 472.8) were used for quantification. Calibration curves covered a range from 2.5 (lower limit of quantification) to 1000.0ng/mL (upper limit of quantification) in plasma and from 2.5 to 1000.0pg/mg in hair. Validation results demonstrated that rimonabant could be accurately and precisely quantified in both matrixes: accuracy and precision were within 85-115% and within 15% of standard deviation, respectively. Stability studies in plasma showed that rimonabant was stable during the assay procedure, but a 30% decrease was observed for one concentration after 3 weeks at -20 degrees C. This simple and robust LC-MS/MS method can be used for measuring rimonabant concentrations in human plasma and hair either in clinical or in forensic toxicology.  相似文献   

6.
An ammonium-adduct based liquid chromatography-tandem mass spectrometry (LC-MS/MS) method has been developed and validated for the simultaneous determination of three isomeric metabolites of tacrolimus (FK506), 13-O-demethylated (M1), 31-O-demethylated (M2) and 15-O-demethylated (M3) tacrolimus in human whole blood and plasma. These metabolites and the internal standards were extracted from biological matrix by methylbutyl ether (MTBE). Separation was achieved on a Genesis C(18) column with a gradient mobile phase elution. Ammonium-adduct ions formed by a Turbo Ionspray in positive ion mode were used to detect each analyte and internal standard. The MS/MS detection was by monitoring the fragmentation of 807.5-->772.4 (m/z) for M1, 807.5-->754.5 (m/z) for both M2 and M3, 795.5-->760.5 (m/z) for IS1 (FR298701) and 961.5-->908.5 (m/z) for IS2 (FR290198) on a triple quadrupole mass spectrometer (Sciex API 3000). The retention times were approximately 4.1 min for M1, 6.8 min for M2, 6.0 min for M3, and 3.9 min for IS1 and 6.4 min for IS2, respectively. The validated dynamic range was 0.2-20 ng/ml for all three metabolites based on a sample volume of 0.25-ml. The linearity of calibration curves for M1, M2, and M3 in both matrices had a correlation coefficient of >/=0.9984. In whole blood, validation data showed intra-batch (n=6) CVs of 相似文献   

7.
A rapid, sensitive and selective LC-MS/MS method was developed and validated for the quantification of aniracetam in human plasma using estazolam as internal standard (IS). Following liquid-liquid extraction, the analytes were separated using a mobile phase of methanol-water (60:40, v/v) on a reverse phase C18 column and analyzed by a triple-quadrupole mass spectrometer in the selected reaction monitoring (SRM) mode using the respective [M+H]+ ions, m/z 220-->135 for aniracetam and m/z 295-->205 for the IS. The assay exhibited a linear dynamic range of 0.2-100 ng/mL for aniracetam in human plasma. The lower limit of quantification (LLOQ) was 0.2 ng/mL with a relative standard deviation of less than 15%. Acceptable precision and accuracy were obtained for concentrations over the standard curve range. The validated LC-MS/MS method has been successfully applied to study the pharmacokinetics of aniracetam in healthy male Chinese volunteers.  相似文献   

8.
A liquid chromatography-mass spectrometry method (LC-MS/MS) for the quantitative determination of rifaximin in human plasma was developed and validated. In the developed procedure, metoprolol was added to human plasma as an internal standard (IS) and acetonitrile was used to precipitate the plasma proteins before LC-MS/MS analysis. Chromatographic separation was obtained on a RESTEK Pinnacle C18 column (50 mm x 2.1mm, 5 microm) with a mobile phase consisted of ammonium acetate solution (15 mM, pH 4.32) as buffer A and methanol as mobile phase B. Quantification was performed in positive mode using multiple reaction monitoring (MRM) of the transitions m/z 786.1-->754.1 for rifaximin and m/z 268.3-->116.1 for the IS. The assay has been validated over the concentration range of 0.5-10 ng/ml (r=0.9992) based on the analysis of 0.2 ml of plasma. The assay accuracy was between 98.2% and 109%. The within-day and between-day precision was better than 3.9% and 8.9% at three concentration levels. The freeze-thaw stability was also investigated and it was found that both rifaximin and the IS were quite stable. This method provides a rapid, sensitive, specific and robust tool for the quantitative determination of rifaximin in human plasma, which is especially useful for the pharmacokinetic study of rifaximin.  相似文献   

9.
A rapid and sensitive liquid chromatography/tandem mass spectrometry (LC-MS/MS) method has been developed and fully validated to determine HS270, a new histone deacetylase (HDAC) inhibitor, in rat plasma using SAHA as the internal standard (IS). After a single step liquid-liquid extraction with acetoacetate, analytes were subjected to LC-MS/MS analysis using positive electro-spray ionization (ESI(+)) under selected reaction monitoring mode (SRM). The chromatographic separation was achieved on a Hypurity C(18) column (50 mm × 2.1 mm, i.d., 5 μm). The MS/MS detection was conducted by monitoring the fragmentation of m/z 392.3→100.1 for HS270, m/z 265.1→232.1 for IS. The method had a chromatographic running time of 2.5 min and linear calibration curves over the concentrations of 0.5-1000 ng/mL. The recovery of the method was 70.8-82.5% and the lower limit of quanti?cation (LLOQ) was 0.5 ng/mL. The intra- and inter-batch precisions were less than 15% for all quality control samples at concentrations of 1.0, 100.0, and 750.0 ng/mL. The validated LC-MS/MS method has successfully applied to a HS270 pharmacokinetic study after oral doses of 25, 50, 100, 200 mg/kg, and i.v. dose of 5 mg/kg to rats.  相似文献   

10.
A rapid and valid method was developed for simultaneous determination catechin, epicatechin and epicatechin gallate in rat plasmas using scopoletin (103 ng mL(-1)) as an internal standard (IS). The separation was performed on Eclipse plus C18 column (100 mm × 4.6 mm, 1.8 μm) at a flow rate of 0.3 mL min(-1), and acetonitrile-0.1% formic acid was used as mobile phase. The recoveries of three analytes and IS were more than 78.9%. The lower limits of quantitation (LLOQ) in rat plasma were 2.14, 2.38 and 2.08 ng mL(-1) respectively for catechin, epicatechin and epicatechin gallate. Intra-day and inter-day precisions were within 12%. The accuracies were more than 85%. After single oral administration of 15.25 g kg(-1) Cynomorium songaricum extract, C(max) of catechin, epicatechin and epicatechin gallate in rat plasma were respectively 86.69±38.65, 32.57±15.00 and 36.93±12.62 ng mL(-1) while T(max) values were respectively 0.15±0.09, 0.20±0.10 and 0.20±0.13 h. The results demonstrated that the present LC-MS/MS method was sensitive enough for pharmacokinetic study of catichins following oral administration of C. songaricum extract.  相似文献   

11.
This paper describes a stable isotope dilution method for quantification of 3-hydroxyglutaric acid (3-HGA) in body fluids. The method comprises a solid-phase extraction procedure, followed by gas chromatographic separation and negative chemical ionization mass spectrometric detection. This method is selective and sensitive, and enables measurement of 3-HGA concentrations in urine-, plasma-, and CSF- samples of controls. The control ranges for 3-HGA were: urine 0.88-4.5 mmol/mol creatinine (n=12); plasma 0.018-0.10 micro mol/l (n=10), CSF 0.022-0.067 micro mol/l (n=10). We applied this method to measure 3-HGA in body fluids of three patients with glutaric aciduria type I. We also quantified 3-HGA in amniotic fluid of controls (range 0.056-0.11 micro mol/l; n=12) and in two samples from fetuses affected with glutaric aciduria type I.  相似文献   

12.
A simple method using a one-step liquid-liquid extraction (LLE) with methyl-t-butyl ether (MTBE) followed by high-performance liquid chromatography (HPLC) with negative-ion electrospray ionization tandem mass spectrometric (ESI-MS/MS) detection was developed for the determination of cilnidipine in human plasma using benidipine as an internal standard (IS). Acquisition was performed in multiple reaction monitoring (MRM) mode, by monitoring the transitions: m/z 491.1>121.8 for cilnidipine and m/z 504.2>122.1 for IS, respectively. Analytes were chromatographed on a CN column by isocratic elution using 10mM ammonium acetate buffer-methanol (30:70, v/v; adjusted with acetic acid to pH 5.0). Results were linear (r2=0.99998) over the studied range (0.1-20ng/ml) with a total LC-MS/MS analysis time per run of 3min. The developed method was validated and successfully applied to a cilnidipine bioequivalence study in 24 healthy male volunteers.  相似文献   

13.
Total homocysteine (tHcy) and cysteine (tCys) concentrations in biological fluids are routinely used in the clinical diagnosis of genetic and metabolic diseases, and this necessitates the development of rapid and sensitive methods for quantification. Liquid chromatography-electrospray tandem mass spectrometry (LC-MS/MS) was used to measure tHcy and tCys in 23 plasma and 21 urine samples from healthy adults and 14 urine samples from healthy children. The results were compared with a standard high-performance liquid chromatography (HPLC) method. The coefficient of variation (CV) for the LC-MS/MS method ranged from 2.9% to 6.1% for the intraassay and 4.8% to 6.4% for the interassay. Mean recoveries were close to 100% for both plasma and urinary tHcy and tCys. The mean plasma tHcy and tCys concentrations in healthy adults were 8.62 and 261.40 micromol/L, respectively. The mean urinary tHcy and tCys in adults were 0.98 and 22.60 micromol/mmol creatinine, respectively. The mean urinary tHcy and tCys in children were 1.17 and 27.43 micromol/mmol creatinine, respectively. Bland-Altman difference plots of method comparison between LC-MS/MS and HPLC showed good agreement in plasma and urinary tHcy and tCys concentrations. Our method is suitable for rapid measurements, and the reported urinary values in children will help to develop a pediatric reference range for clinical use.  相似文献   

14.
A sensitive method using liquid chromatography with tandem mass spectrometric detection (LC-MS/MS) was developed and validated for the analysis of antihistamine drug azatadine in human plasma. Loratadine was used as internal standard (IS). Analytes were extracted from human plasma by liquid/liquid extraction using ethyl acetate. The organic phase was reduced to dryness under a stream of nitrogen at 30 °C and the residue was reconstituted with the mobile phase. 5 μL of the resulting solution was injected onto the LC-MS/MS system. A 4.6 mm × 150 mm, I.D. 5 μm, Agilent TC-C(18) column was used to perform the chromatographic analysis. The mobile phase consisted of ammonium formate buffer 0.010 M (adjusted to pH 4.3 with 1M formic acid)/acetonitrile (20:80, v/v) The chromatographic run time was 5 min per injection and flow rate was 0.6 mL/min. The retention time was 2.4 and 4.4 min for azatadine and IS, respectively. The tandem mass spectrometric detection mode was achieved with electrospray ionization (ESI) iron source and the multiple reaction monitoring (MRM) (291.3 → 248.2m/z for azatadine, 383.3 → 337.3m/z for IS) was operated in positive ion modes. The low limit of quantitation (LLOQ) was 0.05 ng/mL. The intra-day and inter-day precision of the quality control (QC) samples was 8.93-11.57% relative standard deviation (RSD). The inter-day accuracy of the QC samples was 96.83-105.07% of the nominal values.  相似文献   

15.

Background

Desmosine and Isodesmosine (D/I) are cross-linking amino acids which are present only in mature elastin. Changes in their concentration in body fluids indicate changes in elastin degradation and can be a reflection of tissue elastase activity. This study was undertaken to determine whether continuous therapy with the long-acting bronchodilator Tiotropium bromide (TTP) could result in reductions in D/I as measured by mass spectrometry in plasma, urine and sputum.

Methods

Twelve not currently smoking patients with chronic obstructive pulmonary disease (COPD), never on TTP, were selected for study. Levels of D/I, along with measurements of FVC, FEV1 and FEV1/FVC. were determined before starting TTP daily, and then one and two months after.

Results

D/I decreased in plasma (10 of 12 patients), in sputum all (12 of 12), and in the percentage of free D/I in urine (10 of 12). Most patients showed slight increases in FVC and FEV1 percent predicted over two months.

Conclusion

The results are consistent with an effect of prolonged bronchodilitation by anti-cholinergic blockade to also result in reduced lung elastin degradation.  相似文献   

16.

Background

Desmosine and Isodesmosine (D/I) are cross-linking amino acids which are present only in mature elastin. Changes in their concentration in body fluids indicate changes in elastin degradation and can be a reflection of tissue elastase activity. This study was undertaken to determine whether continuous therapy with the long-acting bronchodilator Tiotropium bromide (TTP) could result in reductions in D/I as measured by mass spectrometry in plasma, urine and sputum.

Methods

Twelve not currently smoking patients with chronic obstructive pulmonary disease (COPD), never on TTP, were selected for study. Levels of D/I, along with measurements of FVC, FEV1 and FEV1/FVC. were determined before starting TTP daily, and then one and two months after.

Results

D/I decreased in plasma (10 of 12 patients), in sputum all (12 of 12), and in the percentage of free D/I in urine (10 of 12). Most patients showed slight increases in FVC and FEV1 percent predicted over two months.

Conclusion

The results are consistent with an effect of prolonged bronchodilitation by anti-cholinergic blockade to also result in reduced lung elastin degradation.  相似文献   

17.
Rhodamine 123 (R123), as a typical of P-gp substrate, was widely used to quantify P-glycoprotein (P-gp) functional efflux activity in vivo. A new, rapid and sensitive method was developed for quantifying R123 in rat plasma using liquid chromatography-tandem mass spectrometry (LC-MS/MS). R123 and Rhodamine 6G (R6G, the internal standard, IS) were extracted from aliquots of plasma with ethyl acetate and dichloromethane (4:1) as the solvent and chromatographic separation was performed using a Zorbax Eclipse Plus C18 column. The mobile phase was composed of A: ammonium formate-formic acid buffer containing 5 mM ammonium formate and 0.1% formic acid and B: methanol (A:B, 5:95, v/v). To quantify R123 and IS respectively, multiple reaction monitoring (MRM) transition of m/z 345.2→285.2 and m/z 443.3→415.2 was performed. The analysis time was 4 min in positive mode; the calibration curve was linear in the concentration range of 1-200 ng/ml. The lowest limit of quantification (LLOQ) reached 1 ng/ml. The intra and inter-day precision were less than 9.2% for the low quality control (QC) level, and 3.4% for other QC levels, respectively, while the intra and inter-day relative errors ranged between -7.4% and 9.1% for three QC concentration levels. The LC-MS/MS method proved to be simple, accurate, reliable and with a shorter running time and has been successfully applied to evaluate the functional activity of P-glycoprotein in an absorption experiment in the rat.  相似文献   

18.
A sensitive and selective LC-MS/MS based bioanalytical method was developed and validated for the quantification of 3-deazaneplanocin A (DZNep), a novel epigenetic anti-tumor drug candidate, in Sprague-Dawley (SD) rat biosamples (plasma, urine, feces and tissue samples). The method comprises a phenylboronic acid (PBA)-containing solid phase extraction procedure, serving for binding and clean-up of DZNep in rat biosamples spiked with tubercidin (as internal standard). The analytes were separated on an Agilent hydrophilic interaction chromatography (HILIC) column. LC-MS/MS in positive ion mode was used to perform multiple reaction monitoring at m/z of 263/135 and 267/135 for DZNep and tubercidin, respectively. The limit of quantification (LOQ) of DZNep in rat biosamples was 20 ng/mL. The data of intra-day and inter-day accuracy were within 15% of nominal concentration while the precision (relative standard deviation) less than 10% for all biosamples. The extraction recoveries for DZNep and tubercidin were consistent and reproducible (around 80%) and the matrix effects were negligible (around 10% suppression) in all biosamples. This method was demonstrated to be applicable for pharmacokinetic studies of DZNep in SD rats.  相似文献   

19.
A liquid chromatography/tandem mass spectrometry (LC-MS/MS) method was established for the determination of 5-aminoimidazole-4-carboxamide (AICA) in human plasma. The method included a solvent extraction of AICA as an ion pair with 1-pentanesulfonate ion and a separation on a Hypersil ODS2 column with the mobile phase of methanol-water (68:32, v/v). Determination was performed using an electrospray ionization source in positive ion mode (ESI(+)). Multiple reaction monitoring (MRM) was utilized for the detection monitoring m/z at 127-->110 for AICA, and 172-->128 for IS. The calibration curve was linear within a range from 20 to 2000 ng/mL and the limit of quantity for AICA in plasma was 20 ng/mL. RSD of intra-assay and inter-assay were no more than 5.90% and 5.65%.  相似文献   

20.
A 96-well protein precipitation, liquid chromatography-tandem mass spectrometry (LC-MS/MS) method has been developed and fully validated for the determination of fudosteine in human plasma. After protein precipitation of the plasma samples (50 microL) by the methanol (150 microL) containing the internal standard (IS), erdosteine, the 96-well plate was vortexed for 5 min and centrifuged for 15 min. The 100 microL supernatant and 100 microL mobile phase were added to another plate and mixed and then the mixture was directly injected into the LC-MS/MS system in the negative ionization mode. The separation was performed on a XB-CN column for 3.0 min per sample using an eluent of methanol-water (60:40, v/v) containing 0.005% formic acid. Multiple reaction monitoring (MRM) using the precursor-product ion transitions m/z 178-->91 and m/z 284-->91 was performed to quantify fudosteine and erdosteine, respectively. The method was sensitive with a lower limit of quantification (LLOQ) of 0.02 microg mL(-1), with good linearity (r>0.999) over the linear range of 0.02-10 microg mL(-1). The within- and between-run precision was less than 5.5% and accuracy ranged from 94.2 to 106.7% for quality control (QC) samples at three concentrations of 0.05, 1 and 8 microg mL(-1). The method was employed in the clinical pharmacokinetic study of fudosteine formulation product after oral administration to healthy volunteers.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号