首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A fluorescence resonance energy-transfer (FRET) sensing system for maltose based on E. coli maltose binding protein (MBP) is demonstrated. The FRET donor portion of the sensing system consists of MBP modified with long wavelength-excitable cyanine dyes (Cy3 or Cy3.5). The novel acceptor portion of the sensor consists of beta-cyclodextrin (beta-CD) modified with either the cyanine dye Cy5 or the dark quencher QSY9. Binding of the modified beta-CD to dye-conjugated MBP results in assembly of the FRET complex. Added maltose displaces the beta-CD-dye adduct and disrupts the FRET complex, resulting in a direct change in fluorescence of the donor moiety. In the use of these FRET pairs, MBP dissociation values for maltose were estimated (0.14-2.90 microM). Maltose limits of detection were in the 50-100 nm range.  相似文献   

2.
Water safety is one of the most pervasive problems afflicting people throughout the world. Microcystin, a hepatotoxin produced by cyanobacteria, poses a growing and serious threat of water safety. According to World Health Organization (WHO), the limit of content of microcystin-LR (MC-LR) in drinking water is as low as 1μg/L; it is thus necessary to explore a sensitive method for the trace detection of microcystins (MCs). Based on the observation of gold nanoparticles (Au NPs) induced graphene oxide (GO) fluorescence quenching, a reliable biosensor was developed here for microcystins detection. MCs could be attached on Au NPs through the interaction with single strand-DNA (ss-DNA) modified on Au NPs, which formed Au-DNA-MCs complexes. These MCs in the complexes could be immunologically recognized by the antibodies adsorbed on GO sheets, as a result, Au NPs were close enough to quench the photoluminescence of GO by the fluorescence resonance energy transfer (FRET). The fluorescence intensity decreased with the increase of MCs as more Au NPs linked onto GO surface. The limit of detection was 0.5 and 0.3μg/L for microcystin-LR and microcystin-RR (MC-RR), respectively, which satisfies the strictest standard of WHO. Well defined results were also obtained in natural lake water and the specificity experiment. The antibody used here could recognize Adda group, the conservative part of MCs, which allowed the biosensor to detect both single toxin and the total content of MCs existing in the water sample.  相似文献   

3.
A homogeneous detection mechanism based on fluorescence resonance energy transfer (FRET) has been developed for two DNA diagnostic tests. In the template-directed dye-terminator incorporation (TDI) assay, a donor dye-labeled primer is extended by DNA polymerase using allele-specific, acceptor dye-labeled ddNTPs. In the dye-labeled oligonucleotide ligation (DOL) assay, a donor dye-labeled common probe is joined to an allele-specific, acceptor dye-labeled probe by DNA ligase. Once the donor and acceptor dyes become part of a new molecule, intramolecular FRET is observed over background intermolecular FRET. The rise in FRET, therefore, can be used as an index for allele-specific ddNTP incorporation or probe ligation. Real time monitoring of FRET greatly increases the sensitivity and reliability of these assays. Change in FRET can also be measured by end-point reading when appropriate controls are included in the experiment. FRET detection proves to be a robust method in homogeneous DNA diagnostic assays.  相似文献   

4.
Cocaine is one of the most abused drugs in the United States and is potentially dangerous when consumed in excess. Its detection is thus important in many areas in the fight against drug trafficking. We have developed an amplified detection method for cocaine based on a strand-displacement polymerization reaction using aptamer recognition. The system mainly consists of a hairpin probe with Cy5 labeled on its 3' end, a primer with FAM labeled on its 5' end, and polymerase. The aptamer sequence is integrated into the 5'-section of the hairpin probe. The primer is designed complementary to the 3' end of the hairpin probe, which is also part of the hairpin stem region. The cocaine induced reaction cycle generates product for detection and thus for signal amplification. The detection limit of this method is 200 nM in about 16 min and the specificity of this approach is excellent. We believe that this strategy will be useful for the development of analytical schemes for a variety of aptamers for small molecules, metal ions, and proteins. This simple scheme employing the strand-displacement polymerization reaction may find wide application in forensic analysis, environmental monitoring, and clinical diagnostics.  相似文献   

5.
A fluorescence resonance energy transfer method for multiplex detection DNA based on gold nanorods had been successfully constructed. This method is simple, easy to operate, good selectivity, no requirement to label the probe molecule and can analyze simultaneously multiple targets of DNA in one sample. The limit of detection for the 18‐mer, 27‐mer and 30‐mer targets is 0.72, 1.0 and 0.43 nM at a signal‐to‐noise ratio of 3. The recoveries of three targets were 96.57–98.07%, 99.12–100.04% and 97.29–99.93%, respectively. The results show that the method can be used to analyze a clinical sample or a biological sample; it also can be used to develop new probes for rapid, sensitive and highly selective multiplex detection of analytes in real samples. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

6.
7.
Fluorescence resonance energy transfer (FRET) is a technique used for quantifying the distance between two molecules conjugated to different fluorophores. By combining optical microscopy with FRET it is possible to obtain quantitative temporal and spatial information about the binding and interaction of proteins, lipids, enzymes, DNA, and RNA in vivo. In conjunction with the recent development of a variety of mutant green fluorescent proteins (mtGFPs), FRET microscopy provides the potential to measure the interaction of intracellular molecular species in intact living cells where the donor and acceptor fluorophores are actually part of the molecules themselves. However, steady-state FRET microscopy measurements can suffer from several sources of distortion, which need to be corrected. These include direct excitation of the acceptor at the donor excitation wavelengths and the dependence of FRET on the concentration of acceptor. We present a simple method for the analysis of FRET data obtained with standard filter sets in a fluorescence microscope. This method is corrected for cross talk (any detection of donor fluorescence with the acceptor emission filter and any detection of acceptor fluorescence with the donor emission filter), and for the dependence of FRET on the concentrations of the donor and acceptor. Measurements of the interaction of the proteins Bcl-2 and Beclin (a recently identified Bcl-2 interacting protein located on chromosome 17q21), are shown to document the accuracy of this approach for correction of donor and acceptor concentrations, and cross talk between the different filter units.  相似文献   

8.
A photoluminescent aptasensor has been developed for the detection of lysozyme based on fluorescence resonance energy transfer (FRET) between the carbon dots (CDs) and graphene oxide (GO). In the sensing system, the CDs‐labeled aptamer is adsorbed onto the GO surface and the photoluminescence (PL) signal of the CDs is effectively quenched by GO. Addition of lysozyme can cause a significant FRET inhibition and recover the PL signal of the CDs due to the specific combination of lysozyme and its aptamer and the removal of the CDs‐labeled aptamer from GO surface. Under optimal conditions, the ratio of PL intensity change at 440 nm of the sensing system before and after the addition of lysozyme shows a good linear relationship against the concentration of lysozyme in the range of 0.01–2 μg/mL, with a low detection limit of 1 × 10?3 μg/mL. In addition, the aptasensor has good selectivity so it can distinguish lysozyme with no or little interference by many other biomolecules. It was applied to the detection of lysozyme in human sera with satisfactory recoveries. The results demonstrate the applicability of the aptasensor for monitoring lysozyme in real samples. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

9.
10.
Fluorescence resonance energy transfer (FRET) detects the proximity of fluorescently labeled molecules over distances >100 A. When performed in a fluorescence microscope, FRET can be used to map protein-protein interactions in vivo. We here describe a FRET microscopy method that can be used to determine whether proteins that are colocalized at the level of light microscopy interact with one another. This method can be implemented using digital microscopy systems such as a confocal microscope or a wide-field fluorescence microscope coupled to a charge-coupled device (CCD) camera. It is readily applied to samples prepared with standard immunofluorescence techniques using antibodies labeled with fluorescent dyes that act as a donor and acceptor pair for FRET. Energy transfer efficiencies are quantified based on the release of quenching of donor fluorescence due to FRET, measured by comparing the intensity of donor fluorescence before and after complete photobleaching of the acceptor. As described, this method uses Cy3 and Cy5 as the donor and acceptor fluorophores, but can be adapted for other FRET pairs including cyan fluorescent protein and yellow fluorescent protein.  相似文献   

11.
Single-molecule fluorescence resonance energy transfer   总被引:18,自引:0,他引:18  
Fluorescent resonance energy transfer (FRET) is a powerful technique for studying conformational distribution and dynamics of biological molecules. Some conformational changes are difficult to synchronize or too rare to detect using ensemble FRET. FRET, detected at the single-molecule level, opens up new opportunities to probe the detailed kinetics of structural changes without the need for synchronization. Here, we discuss practical considerations for its implementation including experimental apparatus, fluorescent probe selection, surface immobilization, single-molecule FRET analysis schemes, and interpretation.  相似文献   

12.
Xia Z  Liu Y 《Biophysical journal》2001,81(4):2395-2402
Green fluorescence protein (GFP)-based fluorescence resonance energy transfer (FRET) is increasingly used in investigation of inter- and intramolecular interactions in living cells. In this report, we present a modified method for FRET quantification in cultured cells using conventional fluorescence microscopy. To reliably measure FRET, three positive control constructs in which a cyan fluorescence protein and a yellow fluorescence protein were linked by peptides of 15, 24, or 37 amino acid residues were prepared. FRET was detected using a spectrofluorometer, a laser scanning confocal microscope, and an inverted fluorescence microscope. Three calculation methods for FRET quantification using fluorescence microscopes were compared. By normalization against expression levels of GFP fusion proteins, the modified method gave consistent FRET values that could be compared among different cells with varying protein expression levels. Whole-cell global analysis using this method allowed FRET measurement with high spatial resolutions. Using such a procedure, the interaction of synaptic proteins syntaxin and the synaptosomal associated protein of 25 kDa (SNAP-25) was examined in PC12 cells, which showed strong FRET on plasma membranes. These results demonstrate the effectiveness of the modified method for FRET measurement in live cell systems.  相似文献   

13.
Use of antisense nucleic acids to modulate expression of particular genes is a promising approach to the therapy of human papillomavirus type 16 (HPV-16)-associated cervical cancer. Understandably, evaluation of the in vivo performance of synthetic antisense oligodeoxynucleotides (AS-ODNs) or ribozymes is of ultimate importance to development of effective antisense tools. Here we report the use of a bacterial reporter system based on the inhibition of fluorescence resonance energy transfer (FRET) to measure the interaction of AS-ODNs with HPV-16 target nt 410-445, using variants of the green fluorescent protein (GFP). An optimal FRET-producing pair was selected with GFP as the donor and yellow fluorescent protein (YFP) as the acceptor molecule. Hybridization of AS-ODNs with a chimaeric mRNA containing the antisense target site flanked by GFP variants resulted in the inhibition of the FRET effect. Use of different linkers suggested that the amino acid content of the linker has no significant effect on FRET effect. Antisense accessibility, tested by RNaseH assays with phosphorothioated target-specific and mutant AS-ODNs, suggested a specific effect on the chimaeric mRNA. FRET inhibition measurements correlated with the presence of truncated proteins confirming true antisense activity over the target. Therefore, FRET inhibition may be used for the direct measurement of AS-ODNs activity in vivo.  相似文献   

14.
Based on the x-ray crystal structure of lipid-free Delta43 apoA-I, two monomers of apoA-I were suggested to bind to a phospholipid bilayer in an antiparallel paired dimer, or "belt orientation." This hypothesis challenges the currently held model in which each of the two apoA-I monomers fold as antiparallel alpha-helices or "picket fence orientation." When apoA-I is bound to a phospholipid disc, the first model predicts that the glutamine at position 132 on one apoA-I molecule lies within 16 A of glutamine 132 in the second monomer, whereas, the second model predicts glutamines at position 132 to be 104 A apart. To distinguish between these models, glutamine at position 132 was mutated to cysteine in wild-type apoA-I to produce Q132C apoA-I, which were labeled with thiol-reactive fluorescent probes. Q132C apoA-I was labeled with either fluorescein (donor probe) or tetramethylrhodamine (acceptor probe) and then used to make recombinant phospholipid discs (recombinant high density lipoprotein (rHDL)). The rHDL containing donor- and acceptor-labeled Q132C apoA-I were of similar size, composition, and lecithin:cholesterol acyltransferase reactivity when compared to rHDL-containing human plasma apoA-I. Analysis of donor probe fluorescence showed highly efficient quenching in rHDL containing one donor- and one acceptor-labeled Q132C apoA-I. rHDL containing only acceptor probe-labeled Q132C apoA-I showed rhodamine self-quenching. Both of these observations demonstrate that position 132 in two lipid-bound apoA-I monomers were in close proximity, supporting the "belt conformation" hypothesis for apoA-I on rHDL.  相似文献   

15.
Here we describe a homogeneous assay for biotin based on bioluminescence resonance energy transfer (BRET) between aequorin and enhanced green fluorescent protein (EGFP). The fusions of aequorin with streptavidin (SAV) and EGFP with biotin carboxyl carrier protein (BCCP) were purified after expression of the corresponding genes in Escherichia coli cells. Association of SAV-aequorin and BCCP-EGFP fusions was followed by BRET between aequorin (donor) and EGFP (acceptor), resulting in significantly increasing 510 nm and decreasing 470 nm bioluminescence intensity. It was shown that free biotin inhibited BRET due to its competition with BCCP-EGFP for binding to SAV-aequorin. These properties were exploited to demonstrate competitive homogeneous BRET assay for biotin.  相似文献   

16.
We have developed a sensitive, one-step, homogeneous open sandwich fluoroimmunoassay (OsFIA) based on fluorescence resonance energy transfer (FRET) and luminescent semiconductor quantum dots (QDs). In this FRET assay, estrogen receptor beta (ER-beta) antigen was incubated with QD-labeled anti-ER-beta monoclonal antibody and Alexa Fluor (AF)-labeled anti-ER polyclonal antibody for 30 min, followed by FRET measurement. The dye separation distance was estimated between 80 and 90 A. The current method is rapid, simple, and highly sensitive, and it did not require the bound/free reagent separation steps and solid-phase carriers. A concentration as low as 0.05 nM (2.65 ng/ml) receptor was detected with linearity. In addition, the assay was performed with commercial antibodies. This assay provides a convenient alternative to conventional, laborious sandwich immunoassays.  相似文献   

17.
An assay method that continuously measures the protein tyrosine phosphatase (PTP)-catalyzed dephosphorylation reaction based on fluorescence resonance energy transfer (FRET) was developed as an improvement of our previously reported discontinuous version [M. Nishikata, K. Suzuki, Y. Yoshimura, Y. Deyama, A. Matsumoto, Biochem. J. 343 (1999) 385-391]. The assay uses oligopeptide substrates that contain (7-methoxycoumarin-4-yl)acetyl (Mca) group as a fluorescence donor and 2,4-dinitrophenyl (DNP) group as a fluorescence acceptor, in addition to a phosphotyrosine residue located between these two groups. In the assay, a PTP solution is added to a buffer solution containing a FRET substrate and chymotrypsin. The PTP-catalyzed dephosphorylation of the substrate and subsequent chymotryptic cleavage of the dephosphorylated substrate results in a disruption of FRET, thereby increasing Mca fluorescence. In this study, we used FRET substrates that are much more susceptible to chymotryptic cleavage after dephosphorylation than the substrate used in our discontinuous assay, thus enabling the continuous assay without significant PTP inactivation by chymotrypsin. The rate of fluorescence increase strictly reflected the rate of dephosphorylation at appropriate chymotrypsin concentrations. Since the continuous assay allows the measurement of initial rate of dephosphorylation reaction, kinetic parameters for the dephosphorylation reactions of FRET substrates by Yersinia, T-cell and LAR PTPs were determined. The continuous assay was compatible with the measurement of very low PTP activity in a crude enzyme preparation and was comparable in sensitivity to assays that use radiolabeled substrates.  相似文献   

18.
Current methods for fluorescence resonance energy transfer (FRET) microscopy of living cells involve taking a series of images with alternating excitation colors in separate camera exposures. Here we present a new FRET method based on polarization that requires only one camera exposure and thereby offers the possibility for better time resolution of dynamic associations among subcellular components. Polarized FRET (p-FRET) uses a simultaneous combination of excitation wavelengths from two orthogonally polarized sources, along with an emission channel tri-image splitter outfitted with appropriate polarizers, to concurrently excite and collect fluorescence from free donors, free acceptors, and FRET pairs. Based upon the throughput in each emission channel as premeasured on pure samples of each of the three species, decoupling of an unknown sample's three polarized fluorescence images can be performed to calculate the pixel-by-pixel concentrations of donor, acceptor, and FRET pairs. The theory of this approach is presented here, and its feasibility is experimentally confirmed by measurements on mixtures of cyan fluorescent protein (CFP), citrine ((Cit) a yellow fluorescent protein variant), and linked fusion proteins (CFP-L16-Cit, CFP-L7-Cit, CFP-L54-Cit) in living cells. The effects of shot noise, acceptor polarization, and FRET efficiency on the statistical accuracy of p-FRET experimental results are investigated by a noise-simulation program.  相似文献   

19.
We used fluorescence resonance energy transfer (FRET) to detect and quantitate the interaction of the sarcoplasmic reticulum Ca-ATPase (SERCA) with phospholamban (PLB) in membranes. PLB inhibits SERCA only at submicromolar Ca. It has been proposed that relief of inhibition at micromolar Ca is due to dissociation of the inhibitory complex. To test this hypothesis, we co-reconstituted donor-labeled SERCA and acceptor-labeled I40A-PLB (superinhibitory, monomeric PLB mutant) in membranes of defined lipid and protein composition, with full retention of Ca-dependent ATPase activity and inhibitory regulation by PLB. FRET from SERCA to PLB was measured as a function of membrane concentrations of PLB and SERCA, and functional activity was measured on the same samples. The data revealed clearly that the stoichiometry of binding is one PLB per SERCA, and that binding is a strict function of the ratio of total PLB to SERCA in the membrane. We conclude that the dissociation constant of PLB binding to SERCA is far less than physiological PLB membrane concentrations. Binding at low Ca (pCa 6.5), where I40A-PLB inhibits SERCA, was virtually identical to that at high Ca (pCa 5.0), where no inhibition was observed. However, the limiting energy transfer at saturating PLB was less at high Ca, indicating a greater donor-acceptor distance. We conclude that (a) the affinity of PLB for SERCA is so great that PLB is essentially a SERCA subunit under physiological conditions and (b) relief of inhibition at micromolar Ca is due to a structural rearrangement within the SERCA-PLB complex, rather than dissociation.  相似文献   

20.
The renaissance of fluorescence resonance energy transfer   总被引:18,自引:0,他引:18  
Recent advances in fluorescence resonance energy transfer have led to qualitative and quantitative improvements in the technique, including increased spatial resolution, distance range, and sensitivity. These advances, due largely to new fluorescent dyes, but also to new optical methods and instrumentation, have opened up new biological applications.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号