共查询到20条相似文献,搜索用时 0 毫秒
1.
The presented approach provides the advanced development of effective, rapid, and versatile electrochemical sensors for a small amount of analytes on potential, cheap, and disposable printed chips. The electrocatalytic activity of this biosensor revealed the feasible detection of hydrogen peroxide at low potential (∼0.09 V) and the detection of a biocontaminant inhibitor (organophosphorus pesticide) in a wide range of concentrations. This efficiency comes from the chemical immobilization of catalysts (Pt nanoparticles) and electron transfer-enlarging materials (carbon nanotubes) on an electrode. Especially, dendrimers raise the stable conjugation of enzymes (acetylcholinesterase/choline oxidase/peroxidase) as well as nanoparticles and carbon nanotubes on an electrode. 相似文献
2.
3.
An amperometric cholesterol biosensor based on multiwalled carbon nanotubes and organically modified sol-gel/chitosan hybrid composite film 总被引:3,自引:0,他引:3
A new type of amperometric cholesterol biosensor based on sol-gel chitosan/silica and multiwalled carbon nanotubes (MWCNTs) organic-inorganic hybrid composite material was developed. The hybrid composite film was used to immobilize cholesterol oxidase on the surface of Prussian blue-modified glass carbon electrode. Effects of some experimental variables such as enzyme loading, concentration of Triton X-100, pH, temperature, and applied potential on the current response of the biosensor were investigated. Analytical characteristics and dynamic parameters of the biosensors with and without MWCNTs in the hybrid film were compared, and the results show that analytical performance of the biosensor can be improved greatly after introduction of the MWCNTs. Response time, sensitivity, linear range, limit of detection (S/N=3), and apparent Michaelis-Menten constant Km are 25s, 0.54 microA mM(-1), 8.0 x 10(-6) to 4.5 x 10(-4) M, 4.0 x 10(-6) M, and 0.41 mM for the biosensor without MWCNTs and 13 s, 1.55 microA mM(-1), 4.0 x 10(-6) to 7.0 x 10(-4) M, 1.0 x 10(-6) M, and 0.24 mM for the biosensor with MWCNTs, respectively. The activation energy of the enzyme-catalyzed reaction was measured to be 42.6 kJ mol(-1). This method has been used to determine the free cholesterol concentration in real human blood samples. 相似文献
4.
Su Y Xie Q Yang Q Tu X Cao Z Jia X Su Z Zhang Y Meng W Yao S 《Biotechnology progress》2007,23(2):473-479
Electrochemical quartz crystal impedance (QCI) technique was utilized to monitor in situ the adsorption of rutin (RT) onto a carbon nanotubes (CNTs)-modified gold electrode and to study the binding process of solution hemoglobin (Hb) to RT immobilized on the electrode. Time courses of the QCI parameters including crystal resonant frequency were simultaneously obtained during the RT adsorption and Hb-RT binding. In contrast to the negligible RT adsorption at a bare gold electrode, the modification by CNTs notably enhanced the amount of adsorption, and almost all of the adsorbed RT molecules were found to be electroactive. On the basis of the frequency response from the binding of adsorbed RT to solution Hb and the diminished electroactivity of adsorbed RT after the formation of the electrochemically inactive RT-Hb adduct, the average binding molar ratio of adsorbed RT to Hb was estimated to be 23.9:1, and the association constant (Ka) for the binding was estimated to be 2.87 x 106 (frequency) and 3.92 x 106 (charge) L mol-1, respectively. Comparable results were obtained from fluorescence quenching measurements in mixed solutions containing RT of fixed concentration and Hb of varying concentrations, demonstrating that the interfacial RT here behaved equivalently in the RT-Hb binding activity compared to that in solution. This work may have presented a new and general protocol involving CNTs to study many other electroactive natural antioxidants or drugs that are at the interface or in solution, their binding with proteins or other biomolecules, and changes of their antioxidant activity after the binding. 相似文献
5.
A new approach was applied to modify gold electrode with a unique polymer composite for selectively detecting dopamine (DA), a neurotransmitter, in the presence of an electroactive species of ascorbic acid (AA). After self-assembly of 11-mercaptoundecanoic acid (MUA) monolayer on gold surface, polyethylene glycol (PEG) was used to perform electrochemical esterification with MUA. In general, AA is the main interference of DA detection in a biological system. The resulting composite layer showed high sensitivity to detect DA but selectively blocked the interference from AA. Furthermore, for the first time, an interesting mechanism was demonstrated from our experimental results, namely, that the catalytic effect of AA on DA is limited by DA concentration when AA/DA>1. The modified electrode showed good reproducibility (+/-2% relative standard deviation), a low detection limit (10 nM), a fast response time (<2s), high sensitivity (86 nA/microM), a wide dynamic range of detection (20 microM), and great selectivity (without AA interference). The discovery is very promising for applications of detection of DA in a physiological environment where a high concentration of AA always exists. 相似文献
6.
A simple and highly sensitive electrochemical impedance spectroscopy (EIS) biosensor based on a thrombin-binding aptamer as molecular recognition element was developed for the determination of thrombin. The signal enhancement was achieved by using gold nanoparticles (GNPs), which was electrodeposited onto a glassy carbon electrode (GCE), as a platform for the immobilization of the thiolated aptamer. In the measurement of thrombin, the change in interfacial electron transfer resistance of the biosensor using a redox couple of [Fe(CN)6]3−/4− as the probe was monitored. The increase of the electron transfer resistance of the biosensor is linear with the concentration of thrombin in the range from 0.12 nM to 30 nM. The association and dissociation rate constants of the immobilized aptamer–thrombin complex were 6.7 × 103 M−1 s−1 and 1.0 × 10−4 s−1, respectively. The association and dissociation constants of three different immobilized aptamers binding with thrombin were measured and the difference of the dissociation constants obtained was discussed. This work demonstrates that GNPs electrodeposited on GCE used as a platform for the immobilization of the thiolated aptamer can improve the sensitivity of an EIS biosensor for the determination of protein. This work also demonstrates that EIS method is an efficient method for the determination of association and dissociation constants on GNPs modified GCE. 相似文献
7.
Jun Wan 《Analytical biochemistry》2009,386(2):256-59
A novel nanocomposite material of multiwalled carbon nanotubes (MWCNTs) and room temperature ionic liquid (RTIL) N-butylpyridinium hexafluorophosphate (BPPF6) was explored and used to construct a novel microperoxidase-11 (MP-11) biosensor for the determination of hydrogen peroxide (H2O2). Cyclic voltammetry (CV) and differential pulse voltammetry (DPV) were used to characterize the performance of the biosensor. Under the optimized experimental conditions, H2O2 could be detected in a linear calibration range of 0.5 to 7.0 × 10−7 mol L−1 with a correlation coefficient of 0.9949 (n = 9) and a detection limit of 3.8 × 10−9 mol L−1 at 3σ. The modified electrodes displayed excellent electrochemical response, high sensitivity, long-term stability, and good bioactivity and selectivity. 相似文献
8.
Electrochemically active composite film containing multiwalled carbon nanotubes (MWCNTs) and vitamin B12 was synthesized on glassy carbon, gold, and indium tin oxide electrodes by the potentiodynamic method. The presence of MWCNTs in the composite film (MWCNT–B12) modified electrode mediates vitamin B12’s redox reaction, whereas vitamin B12’s redox reaction does not occur at bare electrode. The electrochemical impedance spectroscopy studies reveal that MWCNTs present in MWCNT–B12 film enhance electron shuttling between the reactant and electrode surface. The surface morphology of bare electrode, MWCNT film. and MWCNT–B12 composite film was studied using atomic force microscopy, which reveals vitamin B12 incorporated with MWCNTs. The MWCNT–B12 composite film exhibits promising enhanced electrocatalysis toward hydrazine. The electrocatalysis response of hydrazine at MWCNT film and MWCNT–B12 composite film was measured using cyclic voltammetry and amperometric current–time (i–t) curve techniques. The linear concentration range of hydrazine obtained at MWCNT–B12 composite film using the i–t curve technique is 2.0 μM–1.95 mM. Similarly, the sensitivity of MWCNT–B12 composite film for hydrazine determination using the i–t curve technique is 1.32 mA mM−1 cm−2, and the hydrazine’s limit of detection at MWCNT–B12 composite film is 0.7 μM. 相似文献
9.
Polymer composite fluorescent hydrogel film based on nitrogen‐doped carbon dots and their application in the detection of Hg2+ ions 下载免费PDF全文
A simple microwave‐assisted solvothermal method was used to prepare fluorescent nitrogen‐doped carbon dots (N‐CDs) with high fluorescence quantum yield (79.63%) using citric acid and N‐(2‐hydroxyethyl)ethylenediamine as starting materials. The PVAm‐g‐N‐CDs grafted products were synthesized by amide bond formation between the carboxylic groups of N‐CDs and amine groups of polyvinylamine (PVAm). Fluorescent hydrogel films (PVAm‐g‐N‐CDs/PAM) were synthesized by interpenetration polymer network polymerization of PVAm‐g‐N‐CDs and acrylamide (AM). When used for ion detection, we found that the fluorescence of the hydrogel films was clearly quenched by addition of Hg2+. Repeatability tests on using the hydrogel films for Hg2+ detection showed that they could be applied at least three times. The PVAm‐g‐N‐CDs/PAM could serve as an effective fluorescent sensing platform for sensitive detection of Hg2+ ions with a detection limit of 0.089 μmol/L. This work may offer a new approach for developing recoverable and sensitive N‐CDs‐based sensors for biological and environmental applications. 相似文献
10.
Lili Bao Le Deng Lihua Nie Shouzhuo Yao Wanzhi Wei 《Biosensors & bioelectronics》1996,11(12):1193-1198
A rapid method for microorganism detection using a piezoelectric quartz crystal sensor (PQC) coated with a thin liquid culture medium film was developed and applied to detect the cell number of Proteus vulgaris. This method employed the viscosity and density response of PQC and utilized the coagulation of gelatine medium solution in which the microorganisms had grown to determine the microorganism indirectly. Three time points (TT1, DT, TT2) were obtained from the coagulation curve and were found to be in good linear relationship with the logarithm of the initial number of P. vulgaris in the range 1·3 × 102−1·3 × 105 cells/ml. The detection was rapid and accurate because the coagulation of the thin liquid culture medium film was quick and the time points in the response curve were sharp and so were easy to determine accurately. The detection time was less than 4 h and only a micro sample was needed. A 5 h preincubation was needed before detection. Some experimental conditions are discussed in detail. 相似文献
11.
A biosensor based on bovine serum albumin (BSA) for the detection of lead (Pb(2+)) ion was developed and characterized. BSA was immobilized onto a colloidal Au-modified piezoelectric quartz crystal (PQC) as a biosensor for the detection of Pb(2+) ion by piezoelectric quartz crystal impedance (PQCI). Calibration curves for the quantification of Pb(2+) ion showed excellent linearity throughout the concentration range from 1.0 x 10(-7) to 3.0 x 10(-9)mol/L. The interaction between the Pb(2+) ions and the sensor chip is influenced significantly by the pH of the reaction buffer, and the optimal pH for the experiment was 5.4. Under the optimal conditions, the detection limit of 1.0 x 10(-9)mol/L for Pb(2+) was obtained. Kinetic parameters of the Pb(2+)-BSA interactions were also determined by using this chip. The sensor chip could be regenerated for use by dipping in the ethylenediaminetetraacetic acid (EDTA) solution for approximately 2h, and the chip was used to detect Pb(2+) ion for eight times without obvious signal attenuation. 相似文献
12.
This study presents the development of a QCM immunosensor for the detection of Listeria monocytogenes. A self-assembled monolayer (SAM) of thiosalicylic acid is incorporated for the covalent attachment of antibodies to the gold surface of the piezoelectric crystal. A non-Sauerbrey increase in frequency is observed upon exposure of such a crystal to specific antigen cells. This unexpected response is consistent with the obtained results and is shown to be specific. The sensor can detect L. monocytogenes cells in real time in solution to 1 × 107 cells/ml. The sensor is reusable more than 10 times without detectable loss in activity and shows negligible response to a non-specific pathogen, Bacillus cereus. The lifetime of the thiolated crystal was also investigated. 相似文献
13.
An electrochemical biosensor based on functional composite nanofibers for hybridization detection of specific K-ras gene that is highly associated with colorectal cancer via multiple signal amplification strategy has been developed. The carboxylated multiwalled carbon nanotubes (MWCNTs) doped nylon 6 (PA6) composite nanofibers (MWCNTs–PA6) was prepared using electrospinning, which served as the nanosized backbone for thionine (TH) electropolymerization. The functional composite nanofibers [MWCNTs–PA6–PTH, where PTH is poly(thionine)] used as supporting scaffolds for single-stranded DNA1 (ssDNA1) immobilization can dramatically increase the amount of DNA attachment and the hybridization sensitivity. Through the hybridization reaction, a sandwich format of ssDNA1/K-ras gene/gold nanoparticle-labeled ssDNA2 (AuNPs–ssDNA2) was fabricated, and the AuNPs offered excellent electrochemical signal transduction. The signal amplification was further implemented by forming network-like thiocyanuric acid/gold nanoparticles (TA/AuNPs). A significant sensitivity enhancement was obtained; the detection limit was down to 30 fM, and the discriminations were up to 54.3 and 51.9% between the K-ras gene and the one-base mismatched sequences including G/C and A/T mismatched bases, respectively. The amenability of this method to the analyses of K-ras gene from the SW480 colorectal cancer cell lysates was demonstrated. The results are basically consistent with those of the K-ras Kit (HRM: high-resolution melt). The method holds promise for the diagnosis and management of cancer. 相似文献
14.
This study aimed to prepare a novel quartz crystal microbalance (QCM) sensor for the detection of pirimicarb. Pirimicarb‐imprinted poly (ethylene glycol dimethacrylate‐N‐metacryloyl‐(l )‐tryptophan methyl ester) [p (EGDMA‐MATrp)] nanofilm (MIP) on the gold surface of a QCM chip was synthesized using the molecular imprinting technique. A nonimprinted p (EGDMA‐MATrp) nanofilm (NIP) was also synthesized using the same experimental technique. The MIP and NIP nanofilms were characterized via Fourier transform infrared spectroscopy attenuated total reflectance spectroscopy, contact angle, atomic force microscopy, and an ellipsometer. A competitive adsorption experiment on the sensor was performed to display the selectivity of the nanofilm. An analysis of the QCM sensor showed that the MIP nanofilm exhibited high sensitivity and selectivity for pirimicarb determination. A liquid chromatography‐tandem mass spectrometry method was prepared and validated to determine the accuracy and precision of the QCM sensor. The accuracy and precision of both methods were determined by a comparison of six replicates at three different concentrations to tomato samples extracted by using a Quick, Easy, Cheap, Effective, Rugged and Safe (QuEChERS) method. The limit of detection of the QCM sensor was found to be 0.028 nM. In conclusion, the QCM sensor showed good accuracy, with recovery percentages between 91 and 94%. Also, the pirimicarb‐imprinted QCM sensor exhibited a fast response time, reusability, high selectivity and sensitivity, and a low limit of detection. Therefore, it offers a serious alternative to the traditional analytical methods for pesticide detection in both natural sources and aqueous solutions. 相似文献
15.
The report is on an electrochemical biosensor with remarkably improved sensitivity toward nitrite. In this strategy, positively
charged gold nanoparticle (PCNA) is used in combination with multiwall carbon nanotubes (MWCNT) by electrostatic adsorption
for fabricating PCNA/MWCNT films. Then hemoglobin (Hb) biocatalyst will easily be attached to the surface of the combination
films aforementioned. After that, the Hb/PCNA films are immobilized onto the Hb/PCNA/MWCNT films through layer-by-layer assembly
technique. The (Hb/PCNA)2/MWNT/GC electrode thus prepared exhibits enhanced electrocatalytic behavior to the reduction of nitrite at −0.10 V versus
SCE in 0.05 M H2SO4 solution. On condition of the low detecting potential and low pH, interference caused by direct electrochemical oxidation or oxidizable
substances can be prevented. Therefore, the modified electrode shows fast response time, very high sensitivity, good selectivity
and stability. The current response of the sensor increases linearly with nitrite concentration from a range of 3.6 × 10−6 to 3.0 × 10−3 M with a detection limit(S /N = 3) of 9.6 × 10−7 M. 相似文献
16.
A novel biosensor has been constructed by the electrodeposition of Au-nanoclusters (nano-Au) on poly(3-amino-5-mercapto-1,2,4-triazole) (p-TA) film modified glassy carbon electrode (GCE) and employed for the simultaneous determination of dopamine (DA), ascorbic acid (AA), uric acid (UA) and nitrite (NO2−). NH2 and SH groups exposed to the p-TA layer are helpful for the electrodeposition of nano-Au. The combination of nano-Au and p-TA endow the biosensor with large surface area, good biological compatibility, electricity and stability, high selectivity and sensitivity and flexible and controllable electrodeposition process. In the fourfold co-existence system, the linear calibration plots for AA, DA, UA and NO2− were obtained over the range of 2.1–50.1 μM, 0.6–340.0 μM, 1.6–110.0 μM and 15.9–277.0 μM with detection limits of 1.1 × 10−6 M, 5.0 × 10−8 M, 8.0 × 10−8 M and 8.9 × 10−7 M, respectively. In addition, the modified biosensor was applied to the determination of AA, DA, UA and NO2− in urine and serum samples by using standard adding method with satisfactory results. 相似文献
17.
A biosensor for trace metal ions based on horseradish peroxidase (HRP) immobilized on maize tassel-multiwalled carbon nanotube (MT-MWCNT) through electrostatic interactions is described herein. The biosensor was characterized using Fourier transform infrared (FTIR), UV–vis spectrometry, voltammetric and amperometric methods. The FTIR and UV–vis results inferred that HRP was not denatured during its immobilization on MT-MWCNT composite. The biosensing principle was based on the determination of the cathodic responses of the immobilized HRP to H2O2, before and after incubation in trace metal standard solutions. Under optimum conditions, the inhibition rates of trace metals were proportional to their concentrations in the range of 0.092–0.55 mg L−1, 0.068–2 mg L−1 for Pb2+ and Cu2+ respectively. The limits of detection were 2.5 μg L−1 for Pb2+ and 4.2 μg L−1 for Cu2+. Representative Dixon and Cornish-Bowden plots were used to deduce the mode of inhibition induced by the trace metal ions. The inhibition was reversible and mixed for both metal ions. Furthermore, the biosensor showed good stability, selectivity, repeatability and reproducibility. 相似文献
18.
Murugesan Balamurugan Thangamuthu Madasamy Manickam Pandiaraj Kalpana Bhargava Niroj Kumar Sethy Chandran Karunakaran 《Analytical biochemistry》2015
This work presents a novel electrochemical assay for the collective measurement of nitric oxide (NO) and its metabolites nitrite (NO2−) and nitrate (NO3−) in volume miniaturized sample at low cost using copper(II) chlorophyllin (CuCP) modified sensor electrode. Zinc oxide (ZnO) incorporated screen printed carbon electrode (SPCE) was used as a host matrix for the immobilization of CuCP. The morphological changes of the ZnO and CuCP modified electrodes were investigated using scanning electron microscopy. The electrochemical characterization of CuCP–ZnO–SPCE exhibited the characteristic quasi-reversible redox peaks at the potential +0.06 V versus Ag/AgCl. This biosensor electrode showed a wide linear range of response over NO concentrations from 200 nM to 500 μM with a detection limit of 100 nM and sensitivity of 85.4 nA μM−1. Furthermore, NO2− measurement showed linearity of 100 nM to 1 mM with a detection limit of 100 nM for NO2− and sensitivity of 96.4 nA μM−1. Then, the concentration of NO3− was measured after its enzymatic conversion into NO2−. Using this assay, the concentrations of NO, NO2−, and NO3− present in human plasma samples before and after beetroot supplement were estimated using suitable membrane coated CuCP–ZnO–SPCE and validated with the standard Griess method. 相似文献
19.
The adsorption performance of chitosan (CS) hydrogel beads (CSBs) generated by sodium dodecyl sulfate (SDS) gelation with multi-walled carbon nanotube (CNT) impregnation was investigated for Congo red removal as a model anionic dye. CNT-impregnated CSBs were prepared by four different strategies for dispersing CNTs: (a) in CS solution (CSBN1), (b) in SDS solution (CSBN2), (c) in CS solution containing cetyltrimethylammonium bromide (CTAB) (CSBN3), and (d) in SDS solution for gelation with CTAB-containing CS solution (CSBN4). It was observed from FE-SEM study that depending on nature of CNT dispersion, CNTs were found on the outer surface of CSBN2 and CSBN4 only. The adsorption capacity of the CSBs varied with the strategy used for CNT impregnation, and CSBN4 exhibited the highest maximum adsorption capacity (375.94 mg/g) from the Sips model. The lowest Sips maximum adsorption capacity by CSBN3 (121.07 mg/g) suggested significant blocking of binding sites of CS by CNT impregnation. 相似文献
20.
Djellouli N Rochelet-Dequaire M Limoges B Druet M Brossier P 《Biosensors & bioelectronics》2007,22(12):2906-2913
In this study, neutravidin-coated screen-printed carbon sensors were fully characterized and further used for the amperometric detection of specific DNA sequences of human cytomegalovirus (HCMV DNA). For this purpose, we took advantage of an earlier established relationship between the amount of HRP affinity immobilized on the surface of the electrode and the steady-state current recorded in the presence of H2O2 as substrate and the single electron donor [OsIII(bpy)2pyCl]2+ as cosubstrate. After incubating a saturating concentration of biotinylated horseradish peroxidase (Bio-HRP) onto the neutravidin-modified sensors, a surface concentration of active HRP of 3.6 pmol cm−2 was calculated from the measurement of the electrocatalytic plateau current value. This result indicates that monolayers of neutravidin were adsorbed on the screen-printed carbon sensors. These neutravidin-covered platforms were then used to immobilize biotinylated nucleic acid targets. After hybridization with a complementary digoxigenin-labeled detection probe, the extent of hybrids formed was determined with an anti-digoxigenin HRP conjugate. The biosensor assay was applied to the detection of a synthetic oligonucleotide target, and then to the determination of an amplified viral DNA sequence. Monolayers of HRP-labeled oligonucleotide hybrids were immobilized onto the sensing surface whereas one third of the surface was covered with HCMV DNA hybrids. On the other hand, detection limits of 200 pM and 1 nM were obtained for the short oligonucleotide and the longer DNA targets, respectively. Finally, we demonstrated that the sensitivity of the electrochemical assay could be significantly improved by using high concentrations of the reduced form of the mediator [OsII(bpy)2pyCl]+, thus allowing one to detect as low as 30 pM of amplified HCMV DNA fragment. 相似文献