首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Quartz crystal microbalance (QCM) sensors are widely used for determining liquid properties or probing interfacial processes. For some applications the sensitivity of the QCM sensors typically used (5–20 MHz) is limited compared with other biosensor methods. In this study ultrasensitive QCM sensors with resonant frequencies from 39 to 110 MHz for measurements in the liquid phase are presented. The fundamental sensor effect of a QCM is the decrease of the resonant frequency of an oscillating quartz crystal due to the binding of mass on a coated surface during the measurement. The sensitivity of QCM sensors increases strongly with an increasing resonant frequency and, therefore, with a decreasing thickness of the sensitive area. The new kind of ultrasensitive QCM sensors used in this study is based on chemically milled shear mode quartz crystals which are etched only in the center of the blank, forming a thin quartz membrane with a thick, mechanically stable outer ring. An immunoassay using a virus specific monoclonal antibody and a M13-Phage showed an increase in the signal to noise ratio by a factor of more than 6 for 56 MHz quartz crystals compared with standard 19 MHz quartz crystals, the detection limit was improved by a factor of 200. Probing of acoustic properties of glycerol/water mixtures resulted in an increase in sensitivity, which is in very good agreement with theory. Chemically milled QCM sensors strongly improve the sensitivity in biosensing and probing of acoustic properties and, therefore, offer interesting new application fields for QCM sensors.  相似文献   

2.
The water sorption isotherm and the water vapor activity dependence of the enthalpy of water sorption Delta(sorp)Hdegrees of lysozyme have been measured at 25 degrees C. A thin film of lysozyme of mass 250 microg was exposed to H2O/N2 mixtures in a quartz crystal microbalance/heat conduction calorimeter (QCM/HCC). The QCM/HCC is a new gravimetric/calorimetric method that measures simultaneously and with high precision the mass change and the corresponding heat flow in a thin film exposed to a gas. Delta(sorp)Hdegrees for lysozyme agrees with previous determinations, although hysteresis effects are evident in the data. No van't Hoff analysis is necessary because sorption enthalpies are measured calorimetrically. The water vapor activity dependence of Delta(sorp)Hdegrees agrees with that measured previously by Bone. As the water content of the lysozyme film drops below 10 mass%, Delta(sorp)Hdegrees becomes more exothermic, indicating that water is being bound to the charged or highly polar groups of the solvent-accessible surface of lysozyme. The dynamics of water uptake and release from lysozyme thin films are much slower than in polymer films of comparable thickness. Because the QCM/HCC operates with sub-milligram samples, any protein is now amenable to study by this technique.  相似文献   

3.
Marx KA 《Biomacromolecules》2003,4(5):1099-1120
The quartz crystal microbalance (QCM) is a simple, cost effective, high-resolution mass sensing technique, based upon the piezoelectric effect. As a methodology, the QCM evolved a solution measurement capability in largely analytical chemistry and electrochemistry applications due to its sensitive solution-surface interface measurement capability. The technique possesses a wide detection range. At the low mass end, it can detect monolayer surface coverage by small molecules or polymer films. At the upper end, it is capable of detecting much larger masses bound to the surface. These can be complex arrays of biopolymers and biomacromolecules, even whole cells. In addition, the QCM can provide information about the energy dissipating properties of the bound surface mass. Another important and unique feature of the technique is the ability to measure mass and energy dissipation properties of films while simultaneously carrying out electrochemistry on solution species or upon film systems bound to the upper electrode on the oscillating quartz crystal surface. These measurements can describe the course of electropolymerization of a film or can reveal ion or solute transport within a film during changes in the film environment or state, including the oxidation state for an electroactive film driven by the underlying surface potential. The past decade has witnessed an explosive growth in the application of the QCM technique to the study of a wide range of molecular systems at the solution-surface interface, in particular, biopolymer and biochemical systems. In this report, we start with a brief historical and technical overview. Then we discuss the application of the QCM technique to measurements involving micellar systems, self-assembling monolayers and their phase transition behavior, molecularly imprinted polymers, chemical sensors, films formed using the layer-by-layer assembly technique, and biopolymer films and point out the utility of the electrochemical capabilities of the technique to characterizing film properties, especially electroactive polymer films. We also describe the wide range of surface chemistries and attachment strategies used by investigators to bring about surface attachment and multi-layer interactions of these thin film systems. Next we review the wide range of recent applications of the technique to: studies of complex biochemical and biomimetic systems, the creation of protein and nucleic acid biosensors, studies of attached living cells and whole cell biosensor applications. Finally, we discuss future technical directions and applications of the QCM technique to areas such as drug discovery.  相似文献   

4.
Molecularly imprinted polymers (MIPs) are gaining great interest as tailor-made recognition materials for the development of biomimetic sensors. Various approaches have been adopted to interface MIPs with different transducers, including the use of pre-made imprinted particles and the in situ preparation of thin polymer layers directly on transducer surfaces. In this work we functionalized quartz crystal microbalance (QCM) sensor crystals by coating the sensing surfaces with pre-made molecularly imprinted nanoparticles. The nanoparticles were immobilized on the QCM transducers by physical entrapment in a thin poly(ethylene terephthalate) (PET) layer that was spin-coated on the transducer surface. By controlling the deposition conditions, it was possible to gain a high nanoparticle loading in a stable PET layer, allowing the recognition sites in nanoparticles to be easily accessed by the test analytes. In this work, different sensor surfaces were studied by micro-profilometry and atomic force microscopy and the functionality was evaluated using quartz crystal microbalance with dissipation (QCM-D). The molecular recognition capability of the sensors were also confirmed using radioligand binding analysis by testing their response to the presence of the test compounds, (R)- and (S)-propranolol in aqueous buffer.  相似文献   

5.
Self-assembled multilayers comprised of alternate layers of polyphenol oxidase (PPO) and poly(allylamine) (PAH) or PPO and poly(diallyldimethylamine) (PDDA), deposited on a 3-mercaptopropanesulfonic acid (MPS)-modified gold surface, were studied "in-situ" (under water) by means of ellipsometry and quartz crystal microbalance (QCM), and "ex-situ" (in open air) by ellipsometry and fourier transform infrared reflection-absorption spectroscopy (FT-IRRAS). Optical ellipsometric properties of (PAH)(n)(PPO)(n) and (PDDA)(n)(PPO)(n) multilayers were obtained at two wavelengths, employing an isotropic single-layer model with the substrate parameters measured after thiol adsorption. Film thickness as well as ellipsometric mass values based on the de Feijter equation were also evaluated. The quartz crystal impedance analysis showed that self-assembled multilayers behaved as acoustically thin films, and therefore, the shifts observed in the film inductive impedance parameter were interpreted in terms of gravimetric mass. The enzyme mass up-take in each adsorption step was determined on PAH or on PDDA topmost layer. A comparative study between the ellipsometric thickness and acoustic mass values allowed us to obtain average values of "apparent" densities of (2.1 +/- 0.1) and (2.4 +/- 0.1) g cm(-3) for (PAH)(n)(PPO)(n) and (PDDA)(n)(PPO)(n) multilayers, respectively. The content of water included in the open polymer-enzyme structure was evaluated by comparison of QCM and ellipsometric mass values. FT-IRRAS spectra of each layer in (PAH)(n)(PPO)(n) and (PDDA)(n)(PPO)(n) films were recorded, and the intensity ratio of the amide bands was evaluated to obtain information about layer-by-layer enzyme conformation. An enzyme/polycation distribution model for (PAH)(n)(PPO)(n)and (PDDA)(n)(PPO)(n) multilayer structures is presented on the basis of combined ellipsometric, QCM, and FT-IRRAS results.  相似文献   

6.
Direct and sensitive detection of a human virus by rupture event scanning   总被引:3,自引:0,他引:3  
We have developed a sensitive, economical method that directly detects viruses by making use of the interaction between type 1 herpes simplex virus (HSV1) and specific antibodies covalently attached to the oscillating surface of a quartz crystal microbalance (QCM). The virions were detached from the surface by monotonously increasing the amplitude of oscillation of the QCM, while using the QCM to sensitively detect the acoustic noise produced when the interactions were broken. We term this process rupture event scanning (REVS). The method is quantitative over at least six orders of magnitude, and its sensitivity approaches detection of a single virus particle.  相似文献   

7.
Bacterial meningitis is an infection of the thin membranes covering the brain and spinal cord by a number of microorganisms including Neisseria meningitidis, which can lead to permanent neurological damage in the event of late diagnosis. Given the quick onset and severity of the disease, there is a clear need for a rapid, sensitive and specific diagnostic technique. Here, we describe the development and evaluation of an acoustic wave sensor, the quartz crystal microbalance (QCM), as a rapid immunosensor employing antibodies against the cell surface outer membrane protein 85 (OMP85) of N. meningitidis as an immobilized selective layer. These antibodies were directionally orientated as receptors by thin film deposition of structured polyvinylidene fluoride and Protein A. The sensitivity of this QCM immunosensor was further increased by conjugation of the OMP85 antigen to 50 nm gold nanoparticles providing reproducible detection of the target down to 300 ng/mL. Subsequent treatment of the QCM surface with an acidic glycine solution regenerated the immunosensor allowing each crystal to be used several times.  相似文献   

8.
Missing mass effect in biosensor's QCM applications   总被引:1,自引:0,他引:1  
Nowadays, liquid applications of quartz crystal microbalance (QCM) opened a way for in situ studies of proteins, vesicles and cells adsorbed from the solution onto the QCM surface. The sensitivity of QCM to the viscoelasticity of the adsorbed biomaterial can be a reason of the experimentally observed deviation from a linear dependence of QCM resonant frequency on mass deposition (the so-called Sauerbrey relation) and can limit its application for biosensoring. Presented here rigorous theoretical analysis explains the deviation from ideal mass response of soft overlayers in the contact with liquid. The fundamental result of the theory is the analog of Sauerbrey relation for layered viscous/viscoelastic medium which can be exploited for the correct physical interpretation of QCM experimental data in biofluids, in particular for measurements of the 'true' surface mass of adsorbed biomolecular films. We predict a new physical effect 'missing mass' of the sample in liquid phase measurements and compare the results given by our theory with QCM measurements on supported membranes.  相似文献   

9.
The use of a commercial, silver-coated quartz crystal microbalance (QCM) as a disposable, low-cost, and reliable DNA sensor is presented. This is an incorporation of polymer-based silver electrode shielding and photochemistry-based surface modification for covalent DNA immobilization. To prevent undesired oxidation, the silver electrodes are coated with thin polystyrene films. The polymer surfaces are then modified by a photoreactive biotin derivative (photobiotin) under UV irradiation. The resulting biotin residues on the polymer-shielded surface react with a tetrameric avidin. Consequently a biotin-labeled DNA probe can be immobilized through a biotin-avidin-biotin bridge. A 14-mer single-stranded biotin-DNA probe and a 70-mer single-stranded DNA fragment containing complementary or noncomplementary sequences are used as a model system for DNA hybridization assay on the proposed sensors. The shielding ability of the polystyrene coatings after photo irradiation is investigated. The DNA probe binding capacity, hybridization efficiency, and kinetics are also investigated.  相似文献   

10.
A factor limiting the detection time of biological particles using a quartz crystal microbalance (QCM) system is the kinetics of the particles arriving within the sensing region of the crystal surface. A device has been developed which, for the first time, combines ac electro-kinetic particle manipulation with simultaneous acoustic sensing on an electrode surface. We have termed this device a dielectrophoretic quartz crystal microbalance (DEP-QCM). Particles within the system are rapidly driven by electro-hydrodynamic and dielectrophoretic forces on to the crystal surface. Frequency shift analysis of mass-loaded DEP-QCM, induced by fluid motion, has shown significant improvements in rates of detection based on particle concentration, with steady-state responses established by a factor of five times faster than other quartz crystal microbalance surface loading techniques described in the literature. Comparisons of the static fluid case for QCM devices revealed that particles with a concentration of less than 10(8) nano-spheres/ml could not be detected within a 1h time period when allowed to sediment.  相似文献   

11.
Acoustic sensors that exploit resonating quartz crystals to directly detect the binding of an analyte to a receptor are finding increasing utility in the quantification of clinically relevant analytes. We have developed a novel acoustic detection technology, which we term resonant acoustic profiling (RAP). This technology builds on the fundamental basics of the "quartz crystal microbalance" or "QCM" with several key additional features including two- or four-channel automated sample delivery, in-line referencing and microfluidic sensor 'cassettes' that are pre-coated with easy-to-use surface chemistries. Example applications are described for the quantification of myoglobin concentration and its interaction kinetics, and for the ranking of enzyme-cofactor specificities.  相似文献   

12.
In this study we evaluate the strengths and weaknesses of surface plasmon resonance (SPR) spectroscopy and quartz crystal microbalance (QCM) technique for studying DNA assembly and hybridization reactions. Specifically, we apply in parallel an SPR instrument and a 5 MHz QCM device with dissipation monitoring (QCM-D) to monitor the assembly of biotinylated DNA (biotin-DNA) on a streptavidin-modified surface and the subsequent target DNA hybridization. Through the parallel measurements, we demonstrate that SPR is more suitable for quantitative analysis of DNA binding amount, which is essential for interfacial DNA probe density control and for the analysis of its effect on hybridization efficiency and kinetics. Although the QCM is not quantitative to the same extent as SPR (QCM measures the total mass of the bound DNA molecules together with the associated water), the dissipation factor of the QCM provides a qualitative measure of the viscoelastic properties of DNA films and the conformation of the bound DNA molecules. The complexity in mass measurement does not impair QCM's potential for a kinetic evaluation of the hybridization processes. For quantification of target DNA, the biotin-DNA modified SPR and QCM sensors are exposed to target DNA with increasing concentration. The plots of SPR/QCM signals versus target DNA concentration show that water entrapment between DNA strands make the QCM sensitivity for the hybridization assay well comparable with that of the SPR, although the intrinsic mass sensitivity of the 5 MHz QCM is approximately 20 times lower.  相似文献   

13.
The adsorption behavior of chitosan on poly(ethylene terephthalate) (PET) model film surface was studied using the quartz crystal microbalance (QCM) technique. QCM with a dissipation unit (QCM-D) represents a very sensitive technique for adsorption studies at the solid/liquid interface in situ, with capability of detecting a submonolayer of adsorbate on the quartz crystal surface. Chitosan as well as PET were chosen for this study due to their promising biocompatible properties and numerous possibilities to be used in biomedical applications. As a first step, PET foils were activated by alkaline hydrolysis in order to increase their hydrophilicity. Model thin films were prepared from PET foils by the spin coating technique. The chemical composition of the obtained model PET films was analyzed using X-ray photoelectron spectroscopy (XPS) and their morphology was characterized by atomic force microscopy (AFM). Furthermore, the adsorption behavior of chitosan on these activated PET films and the influence of adsorption parameters (pH, ionic strength and chitosan solution concentration) were investigated in detail. Additionally, the surface chemistry and morphology of the PET films and the chitosan coated PET films were analyzed with XPS and AFM.  相似文献   

14.
By means of the quartz crystal microbalance (QCM), a convenient method was developed to determine the degree of orientation of purple membrane (PM) sheets on the air/water interface. Langmuir-Blodgett films from both wild-type and SH-mutant PM (bR D36C) were vertically deposited on the surface of gold-sputtered AT-cut quartz crystals. The shift of resonance frequency of the QCM during a special washing protocol allowed us to differentiate between physically adsorbed PM fragments and any PM attached to the gold surface via chemical bonds. By washing with organic solvents, complete desorption of the wild-type PM was achieved, whereas for the SH-mutant, approximately 60% of the PM fragments could not be detached from the surface. These PM sheets should be oriented with the cytoplasmic side facing the water subphase to that their SH-groups can chemically bind to the gold surface of the quartz plate.  相似文献   

15.
Recent applications of quartz crystal resonant sensor technology to monitor cell adhesion and specific ligand interaction processes has triggered the development of a new category of quartz crystal microbalance (QCM) based biosensors. In this study human oral epithelial cells (H376) were cultured on quartz sensors and their response to microspheres investigated in situ using the QCM technique. The results demonstrated that this novel biosensor was able to follow cell-microsphere interactions in real-time and under conditions of flow as would occur in the oral cavity. Unique frequency profiles generated in response to the microspheres were postulated to be due to phases of mass addition and altered cellular rigidity. Supporting microscopic evidence demonstrated that the unique frequency responses obtained to these interactions were in part due to binding between the cell surface and the microspheres. Furthermore, a cellular uptake process, in response to microsphere loading was identified and this, by influencing the rigidity of the cellular cytoskeleton, was also detectable through the frequency responses obtained.  相似文献   

16.
Biodegradation of solution-cast starch films by Bacillus subtilis was monitored using a quartz crystal microbalance (QCM). A starch film was formed on the crystal by solution casting and exposed to the Bacillus subtilis culture in a bioreactor. The high sensitivity of the QCM could monitor small weight changes of the starch films on the crystal in the initial stages of biodegradation by secreted exo-enzymes of the bacterium. The feasibility of this approach as a means of quantification and characterisation of biodegradability of different polymeric materials by selected organisms is discussed.  相似文献   

17.
A bilirubin imprinted polymer (BIP) was coated on a thiol pretreated Au electrode on a quartz crystal microbalance (QCM) chip. The BIP thin film was synthesized using 4-vinylpyridine (4-Vpy) as the monomer, divinylbenzene (DVB) as the cross-linker, and benzophenone as the initiator. By using a photo-graft surface polymerization technique with irradiation by ultra-violet (UV) light, a thin BIP film was prepared, from which a biomimetic sensor for the detection of bilirubin was developed. The sensor was able to discriminate bilirubin in solution owing to the specific binding of the imprinted sites. The BIP/QCM chip has been repeatedly used for more than 7 months in many continuous experiments. The detection signal of bilirubin from the BIP thin film/QCM was compared with the non-BIP thin film/QCM. Biliverdin, an analogue of bilirubin, was used for comparison. The analogue comparison confirmed the binding specificity of the BIP film toward bilirubin. The selectivity can be as high as 31.2. The effect of pH on the detection of bilirubin is also discussed. With proper solvent for elution and recovery, flow injection analysis (FIA) could be applied to the system. The performance of the BIP/QCM chip was evaluated. A linear calibration of the bilirubin concentration with respect to the frequency shift was successfully obtained. The reproducibility of measurements from the same BIP/QCM chip was confirmed. In addition, repeatability of detection was also confirmed from different BIP/QCM chips. In conclusion, a combined BIP thin film/QCM/FIA method was successfully established for the detection of bilirubin concentration using a molecularly imprinted film.  相似文献   

18.
The immobilization efficiency of molecular detectors is of great importance with regard to the performances of biosensors such as the sensitivity, stability, and reproducibility. This paper presents a biomimetic olfactory receptor-based biosensor with better performances by improving the immobilization efficiency of molecular detectors for odorant sensing. A mixed self-assembled monolayers (SAMs) functionalized with specific olfactory receptors (ODR-10) was constructed on the sensitive area of surface acoustic wave (SAW) chip. The immobilization of ODR-10 was characterized by scanning electron microscopy (SEM) and atomic force microscopy (AFM). The responses of this biosensor to various odorants were recorded by monitoring the resonance frequency shifts of SAW, which is correlated to the mass loading on its sensitive area. All the results demonstrate this biosensor can specifically respond to the natural ligand of ODR-10, diacetyl, with high sensitivity and stability. The sensitivity is 4 kHz/ng, which is 2× higher than that of previous work. The detection limit is 1.2×10(-11) mM. The major advances on immobilization efficiency of molecular detectors presented in this work could substantially promote and accelerate the researches and applications of olfactory receptor-based biosensors with different transducers, such as quartz crystal microbalance (QCM), surface plasma resonance (SPR), and field effect transistors (FET).  相似文献   

19.
Skin is constantly exposed to surfactants which compromise the essential barrier function of normal healthy skin. To model the interactions of surfactants with the barrier lipids of the stratum corneum (SC), it is essential to develop in vitro and in vivo quantitative measurement methods to predict, evaluate, and demonstrate the effect of the different surfactant chemistries and technologies on skin. In the current work, in vitro water vapor uptake and surfactant absorption onto skin lipid model films were quantitatively studied using a technique based on the piezoelectric effect, the quartz crystal microbalance (QCM). This approach is straightforward and reliable in providing subtle surface/interface related mass change information with high resolution and sensitivity. The results show that barrier properties of the lipid model system may be damaged by surfactant absorption, as well as by long-term water exposure due to alterations to the lipid film structure. Surfactant absorption is found to be concentration dependent even beyond its critical micelle concentration (CMC). QCM results for different surfactant systems are consistent with reported clinical data in showing that clinically milder surfactants (SLES) do not perturb the film as much as clinically harsh surfactants (SDS).  相似文献   

20.
Study on colloidal Au-enhanced DNA sensing by quartz crystal microbalance   总被引:5,自引:0,他引:5  
Colloidal Au is reported for enhancement the immobilization capacity and ultimately detection limit of DNA using quartz crystal microbalance (QCM). Immobilization of approximately 12 nm-diameter colloidal Au on to an Au-coated QCM resulted in an easier attachment of oligonucleotide, with a mercaptohexyl group at the 5'-phosphate end and an increased capacity for nucleic acid detection. DNA immobilization and hybridization was monitored from QCM frequency changes. Hybridization was induced by exposure of the DNA-containing films to complementary DNA in solution. A much higher sensitivity was obtained for the analyte. The Au nanoparticle films on the Au plate provide a novel means for the fabrication of DNA sensor.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号