首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Affinity purification of proteins using antibodies coupled to beads and subsequent mass spectrometric analysis has become a standard technique for the identification of protein complexes. With the recent transfer of the isotope dilution mass spectrometry principle (IDMS) to the field of proteomics, quantitative analyses-such as the stoichiometry determination of protein complexes-have become achievable. Traditionally proteins were eluted from antibody-conjugated beads using glycine at low pH or using diluted acids such as HCl, TFA, or FA, but elution was often found to be incomplete. Using the cohesin complex and the anaphase promoting complex/cyclosome (APC/C) as examples, we show that a short 15-60 min predigestion with a protease such as LysC (modified on-bead digest termed protease elution) increases the elution efficiency 2- to 3-fold compared to standard acid elution protocols. While longer incubation periods-as performed in standard on-bead digestion-led to partial proteolysis of the cross-linked antibodies, no or only insignificant cleavage was observed after 15-60 min protease mediated elution. Using the protease elution method, we successfully determined the stoichiometry of the cohesin complex by absolute quantification of the four core subunits using LC-SRM analysis and 19 reference peptides generated with the EtEP strategy. Protease elution was 3-fold more efficient compared to HCl elution, but measurements using both elution techniques are in agreement with a 1:1:1:1 stoichiometry. Furthermore, using isoform specific reference peptides, we determined the exact STAG1:STAG2 stoichiometry within the population of cohesin complexes. In summary, we show that the protease elution protocol increases the recovery from affinity beads and is compatible with quantitative measurements such as the stoichiometry determination of protein complexes.  相似文献   

2.
The current study presents a new miniature microfluidic flow cytometer integrated with several functional micro-devices capable of viral sample purification and detection by utilizing a magnetic bead-based immunoassay. The magnetic beads were conjugated with specific antibodies, which can recognize and capture target viruses. Another dye-labeled anti-virus antibody was then used to mark the bead-bound virus for the subsequent optical detection. Several essential components were integrated onto a single chip including a sample incubation module, a micro flow cytometry module and an optical detection module. The sample incubation module consisting of pneumatic micropumps and a membrane-type, active micromixer was used for purifying and enriching the target virus-bound magnetic beads with the aid of a permanent magnet. The micro flow cytometry module and the optical detection module were used to perform the functions of virus counting and collection. Experimental results showed that virus samples with a concentration of 10(3)PFU/ml can be automatically detected successfully by the developed system. In addition, the entire diagnosis procedure including sample incubation and virus detection took only about 40min. Consequently, the proposed micro flow cytometry may provide a powerful platform for rapid diagnosis and future biological applications.  相似文献   

3.
Commercially available desalting techniques, necessary for downstream MALDI-TOF analysis of proteins, are often costly or time consuming for large-scale analysis. Here, we present techniques to elute proteins from various affinity resins, free from salt and ready for MALDI mass spectrometry. We showed that 0.1% TFA in 50% acetonitrile or 40% ethanol can be used as salt-free eluents for His-tagged proteins from variety of polyhistidine-affinity resins, while washing of resin beads twice with double-distilled water prior to the elution effectively desalted and recovered wide-range-molecular size proteins than commercially available desalting devices. Modified desalting and elution techniques were also applied for Flag- and Myc-tag affinity resins. The technique was further applied in co-precipitation assay, where the maximum recovery of wide-range molecular size proteins is crucial. Further, results showed that simple washing of the beads with double distilled water followed by elution with acetonitrile effectively desalted and recovered 150 kDa factor H protein of the sheep and its binding partner ~30 kDa BbCRASP-1 in co-precipitation assay. In summary, simple modifications in the desalting and elution strategy save time, labor and cost of the protein preparation for MALDI mass spectrometry; and large-scale protein purifications or co-precipitations can be performed with ease.  相似文献   

4.
The growing importance of mass spectrometry for the identification and characterization of bacterial protein toxins is a consequence of the improved sensitivity and specificity of mass spectrometry-based techniques, especially when these techniques are combined with affinity methods. Here we describe a novel method based on the use of immunoaffinity capture and matrix-assisted laser desorption ionization-time of flight mass spectrometry for selective purification and detection of staphylococcal enterotoxin B (SEB). SEB is a potent bacterial protein toxin responsible for food poisoning, as well as a potential biological warfare agent. Unambiguous detection of SEB at low-nanogram levels in complex matrices is thus an important objective. In this work, an affinity molecular probe was prepared by immobilizing anti-SEB antibody on the surface of para-toluene-sulfonyl-functionalized monodisperse magnetic particles and used to selectively isolate SEB. Immobilization and affinity capture procedures were optimized to maximize the density of anti-SEB immunoglobulin G and the amount of captured SEB, respectively, on the surface of magnetic beads. SEB could be detected directly "on beads" by placing the molecular probe on the matrix-assisted laser desorption ionization target plate or, alternatively, "off beads" after its acidic elution. Application of this method to complex biological matrices was demonstrated by selective detection of SEB present in different matrices, such as cultivation media of Staphylococcus aureus strains and raw milk samples.  相似文献   

5.
In this study, a capillary electrophoresis (CE) method was developed as a means to measure levels of penicillin G (PCN G) in Group B Streptococcus (GBS) positive pregnant women during labor and delivery. Volunteers for this developmental study were administered five million units of PCN G at the onset of labor. Urine, blood, and amniotic fluid samples were collected during labor and post delivery. Samples were semi-purified by solid-phase extraction (SPE) using Waters tC18 SepPak 3 cc cartridges with a sodium phosphate/methanol step gradient for elution. Capillary electrophoresis or reversed-phase high-performance liquid chromatography (RP-HPLC) with diode-array absorbance detection were used to separate the samples in less than 30 min. Quantification was accomplished by establishing a calibration curve with a linear dynamic range. The tC18 SPE methodology provided substantial sample clean-up with high recovery yields of PCN G ( 90%). It was found that SPE was critical for maintaining the integrity of the separation column when using RP-HPLC, but was not necessary for sample analysis by CE where no stationary phase is present. Quantification results ranged from millimolar concentrations of PCN G in maternal urine to micromolar concentrations in amniotic fluid. Serum and cord blood levels of PCN G were below quantification limits, which is likely due to the prolonged delay in sample collection after antibiotic administration. These results show that CE can serve as a simple and effective means to characterize the pharmacokinetic distribution of PCN G from mother to unborn fetus during labor and delivery. It is anticipated that similar methodologies have the potential to provide a quick, simple, and cost-effective means of monitoring the clinical efficacy of PCN G and other drugs during pregnancy.  相似文献   

6.
Magnetic poly(ethylene glycol dimethacrylate-N-methacryloyl-(L)-histidine methyl ester) [mag-poly(EGDMA-MAH) beads, 50-100 microm in diameter, were produced by suspension polymerization for affinity depletion of immunoglobulin G (IgG) from human serum. Cu2+ ions were complexed directly via MAH groups (Cu2+ loading: 4.1 micromol/g). IgG depletion studies were performed by magnetically stabilized fluidized bed column. Acetate, Tris-HCl, MES and phosphate buffers all allow adsorption of similar quantities of IgG (27.3-45.6 mg/g). MOPS and HEPES allow higher adsorption quantities (79.6 mg/g and 74.1mg/g, respectively). Maximum adsorption capacities in MOPS buffer were 46.8 mg/g for mag-poly(EGDMA-MAH) and 102.1mg/g for Cu2+ chelated mag-poly(EGDMA-MAH) beads. The adsorption capacity decreased drastically from 102.1mg/g to 30.7 mg/g with the increase of the flow rate from 0.2 ml/min to 3.5 ml/min. The elution studies were performed by 1.0M NaCl. The elution results demonstrated that the adsorption of IgG to the adsorbent was reversible. To test the efficiency of IgG depletion from human serum, proteins in the serum and eluted portion were analyzed by two-dimensional gel electrophoresis. The depletion efficiency for IgG was above 99.4%. Eluted proteins include mainly IgG, and a small number of non-albumin proteins such as apo-lipoprotein A1, sero-transferrin, haptoglobulin and alpha1-antitrypsin. When anti-HSA-sepharose adsorbent is used together with our metal-chelated mag-beads, IgG and HSA can be depleted in a single step.  相似文献   

7.
We present a method for rapid expression and isolation of recombinant proteins. Cell-free protein synthesis in the presence of affinity beads enables in situ isolation of translation products, which simplifies the procedures for the preparation of purified protein samples. In the present study, we have made an attempt to carry out in situ isolation of histidine-tagged proteins by using Ni-NTA magnetic agarose beads. The presence of Ni-NTA beads gave no drastic effects on the efficiency of protein synthesis and successfully captured the synthesized proteins. Purified proteins were obtained after subsequent washing and elution steps. In particular, most of the endogenous bead-binding proteins were removed by pre-treating S30 extract with affinity beads and the purity of the target proteins was enhanced up to 95%. The methods described here will provide a basis for fast and convenient preparation of purified proteins from multiple genetic sequences.  相似文献   

8.
A magnetic beads based affinity-selection methodology towards the screening of acetylcholine binding protein (AChBP) binders in mixtures and pure compound libraries was developed. The methodology works as follows: after in solution incubation of His-tagged AChBP with potential ligands, and subsequent addition of cobalt (II)-coated paramagnetic beads, the formed bead-AChBP-ligand complexes are fetched out of solution by injection and trapping in LC tubing with an external adjustable magnet. Non binders are then washed to the waste followed by elution of ligands to a SPE cartridge by flushing with denaturing solution. Finally, SPE-LC-MS analysis is performed to identify the ligands. The advantage of the current methodology is the in solution incubation followed by immobilized AChBP ligand trapping and the capability of using the magnetic beads system as mobile/online transportable affinity SPE material. The system was optimized and then successfully demonstrated for the identification of AChBP ligands injected as pure compounds and for the fishing of ligands in mixtures. The results obtained with AChBP as target protein demonstrated reliable discrimination between binders with pK(i) values ranging from at least 6.26 to 8.46 and non-binders.  相似文献   

9.
In this study, a label-free relative quantification strategy was developed for quantifying low-abundance glycoproteins in human serum. It included three steps: (1) immunodepletion of 12 high-abundance proteins, (2) enrichment of low-abundance glycoproteins by multi-lectin column, (3) relative quantification of them between different samples by micrOTOF-Q. We also evaluated the specificity and efficiency of immunodepletion, the accuracy of protein quantification and the possible influence of immunodepletion, glycoprotein enrichment, trypsin digestion and peptide ionization on quantification. In conclusion, the relative quantification method can be effectively applied to the screening of low-abundance biomarkers.  相似文献   

10.
A sensitive reversed phase HPLC method with evaporative light scattering detection (ELSD) was developed for the determination of the hydrophobic surfactant protein B (SP-B) in human bronchoalveolar lavage fluid. Samples were extracted two times with CHCl(3):MeOH:HCl (2:3:0.005N) solution in a ratio of 1:2 by volume. The extract of the lower phase was separated on a C4 butyl silica gel column with an isocratic elution using a mobile phase, consisting of 97% methanol, 2.75% chloroform and 0.25% 0.1 M trifluoroacetic acid (by volume), at a flow rate of 1 ml/min. SP-B was detected by ELSD and quantified by comparison to an external standard. The duration of a run was 7 min, the quantification limit 30 ng and the limit of detection was at about 15 ng of SP-B. This method is suitable for the rapid routine quantification of SP-B in human bronchoalveolar lavage fluid samples.  相似文献   

11.
Brand J  Haslberger T  Zolg W  Pestlin G  Palme S 《Proteomics》2006,6(11):3236-3242
The selective removal of high-abundance proteins is considered to be an important prerequisite for a sensitive proteome analysis in plasma. In this study, we examined the "multiaffinity removal system", an immunoaffinity depletion column targeted against six plasma proteins. As determined by sandwich ELISA, the depletion rate for each target protein is >99% over 200 cycles of regeneration. Our data give evidence that two column antibodies are slowly inactivated during the repeated use of the column; however, the individual depletion rate meets the specification of the manufacturer. To estimate a potential loss of analytes after the immunodepletion, we performed spiking/recovery experiments with a selection of tumor markers at concentrations in the lower to medium ng/mL range. The average recovery of 9 out of 11 markers is 78%. A significant proportion of two other markers binds to the column. Based on the average marker recovery and a depletion of ;85% of the total protein we estimate a five-fold enrichment of a potential biomarker by the use of this depletion column. We conclude that the selective depletion of plasma proteins by immunoaffinity chromatography is a valid strategy for the enrichment of potential biomarkers sought by proteomics methodologies.  相似文献   

12.
This report describes an integrated and modular microsystem providing rapid analyses of trace-level tryptic digests for proteomics applications. This microsystem includes an autosampler, a microfabricated device comprising a large channel (2.4 microl total volume), an array of separation channels, together with a low dead volume enabling the interface to nanoelectrospray mass spectrometry. The large channel of this microfluidic device provides a convenient platform to integrate C(18) reverse phase packing or other type of affinity media such as immobilized antibodies or immobilized metal affinity chromatography beads thus enabling affinity selection of target peptides prior to electrophoretic separation and mass spectrometry analyses on a quadrupole/time-of-flight instrument. Sequential injection, preconcentration, and separation of peptide standards and tryptic digests are achieved with a throughput of up to 12 samples/per h and a concentration detection limit of approximately 5 nM (25 fmol on chip). Replicate injections of peptide mixtures indicated that reproducibility of migration time was 1.2-1.8%, whereas relative standard deviation ranging from 9.2 to 11.8% are observed on peak heights. The application of this device for trace-level protein identification is demonstrated for two-dimensional gel spots obtained from extracts of human prostatic cancer cells (LNCap) using both peptide mass-fingerprint data base searching and on-line tandem mass spectrometry. Enrichment of target peptides prior to mass spectral analyses is achieved using c-myc-specific antibodies immobilized on protein G-Sepharose beads and facilitates the identification of antigenic peptides spiked at a level of 20 ng/ml in human plasma. Affinity selection is also demonstrated for gel-isolated protein bands where tryptic phosphopeptides are captured on immobilized metal affinity chromatography beads and subsequently separated and characterized on this microfluidic system.  相似文献   

13.
The strong need for quantitative information in proteomics has fueled the development of mass spectrometry-based analytical methods that are able to determine protein abundances. This article reviews mass spectrometry experiments aimed at providing an absolute quantification of proteins. The experiments make use of the isotope-dilution concept by spiking a known amount of synthetic, isotope-labeled reference peptide into the analyte sample. Quantification is achieved by comparing the mass spectrometry signal intensities of the reference with an endogenous peptide that is generated upon proteolytic cleavage of the target protein. In an analogous manner, the level of post-translational modification at a distinct residue within a target protein can be determined. Among the strengths of absolute quantification are low detection limits reaching subfemtomole levels, a high dynamic range spanning approximately five orders of magnitude, low requirements for sample clean-up, and a fast and straightforward method development. Recent studies have demonstrated the compatibility of absolute quantification with various mass spectrometry readout techniques and sample purification steps such as 1D gel electrophoresis, size-exclusion chromatography, isoelectric peptide focusing, strong cation exchange and reversed phase or affinity chromatography. Under ideal conditions, quantification errors and coefficients of variation below 5% have been reported. However, the fact that at the start of the experiment the analyte is a protein and the internal standard is a peptide, severe quantification errors may result due to the selection of unsuitable reference peptides and/or imperfect protein proteolysis. Within the ensemble of mass spectrometry-based quantification methods, absolute quantification is the method of choice in cases where absolute numbers, many repetitive experiments or precise levels of post-translational modifications are required for a few, preselected species of interest. Consequently, prominent application areas include biomarker quantification, the study of post-translational modifications such as phosphorylation or ubiquitination and the comparison of concentrations of interacting proteins.  相似文献   

14.
The strong need for quantitative information in proteomics has fueled the development of mass spectrometry-based analytical methods that are able to determine protein abundances. This article reviews mass spectrometry experiments aimed at providing an absolute quantification of proteins. The experiments make use of the isotope-dilution concept by spiking a known amount of synthetic, isotope-labeled reference peptide into the analyte sample. Quantification is achieved by comparing the mass spectrometry signal intensities of the reference with an endogenous peptide that is generated upon proteolytic cleavage of the target protein. In an analogous manner, the level of post-translational modification at a distinct residue within a target protein can be determined. Among the strengths of absolute quantification are low detection limits reaching subfemtomole levels, a high dynamic range spanning approximately five orders of magnitude, low requirements for sample clean-up, and a fast and straightforward method development. Recent studies have demonstrated the compatibility of absolute quantification with various mass spectrometry readout techniques and sample purification steps such as 1D gel electrophoresis, size-exclusion chromatography, isoelectric peptide focusing, strong cation exchange and reversed phase or affinity chromatography. Under ideal conditions, quantification errors and coefficients of variation below 5% have been reported. However, the fact that at the start of the experiment the analyte is a protein and the internal standard is a peptide, severe quantification errors may result due to the selection of unsuitable reference peptides and/or imperfect protein proteolysis. Within the ensemble of mass spectrometry-based quantification methods, absolute quantification is the method of choice in cases where absolute numbers, many repetitive experiments or precise levels of post-translational modifications are required for a few, preselected species of interest. Consequently, prominent application areas include biomarker quantification, the study of post-translational modifications such as phosphorylation or ubiquitination and the comparison of concentrations of interacting proteins.  相似文献   

15.
DNA and RNA can be separated by microchip electrophoresis (ME) and detected using an intercalating fluorescent dye. The advantages of this method are short sensing times (<3 min), avoidance of a radioisotope labeling detection system, relatively low costs, and reduced labor intensity. In the present study, RNA aptamer-protein or -peptide interactions were analyzed using ME and the regression of free aptamers corresponding to unbound RNA was detected as the target protein or peptide increased in a dose-dependent manner. Our results demonstrate the applicability of this method to simple, rapid ligand screening in the interactions between oligonucleotides and their targets.  相似文献   

16.
Ahn JY  Jo M  Dua P  Lee DK  Kim S 《Oligonucleotides》2011,21(2):93-100
RNA and DNA aptamers that bind to target molecules with high specificity and affinity have been a focus of diagnostics and therapeutic research. These aptamers are obtained by SELEX often requiring many rounds of selection and amplification. Recently, we have shown the efficient binding and elution of RNA aptamers against target proteins using a microfluidic chip that incorporates 5 sol-gel binding droplets within which specific target proteins are imbedded. Here, we demonstrate that our microfluidic chip in a SELEX experiment greatly improved selection efficiency of RNA aptamers to TATA-binding protein, reducing the number of selection cycles needed to produce high affinity aptamers by about 80%. Many aptamers were identical or homologous to those isolated previously by conventional filter-binding SELEX. The microfluidic chip SELEX is readily scalable using a sol-gel microarray-based target multiplexing. Additionally, we show that sol-gel embedded protein arrays can be used as a high-throughput assay for quantifying binding affinities of aptamers.  相似文献   

17.
The sensitivity and specificity of current Giardia cyst detection methods for foods are largely determined by the effectiveness of the elution, separation, and concentration methods used. The aim of these methods is to produce a final suspension with an adequate concentration of Giardia cysts for detection and a low concentration of interfering food debris. In the present study, a microfluidic device, which makes use of inertial separation, was designed and fabricated for the separation of Giardia cysts. A cyclical pumping platform and protocol was developed to concentrate 10-ml suspensions down to less than 1 ml. Tests involving Giardia duodenalis cysts and 1.90-μm microbeads in pure suspensions demonstrated the specificity of the microfluidic chip for cysts over smaller nonspecific particles. As the suspension cycled through the chip, a large number of beads were removed (70%) and the majority of the cysts were concentrated (82%). Subsequently, the microfluidic inertial separation chip was integrated into a method for the detection of G. duodenalis cysts from lettuce samples. The method greatly reduced the concentration of background debris in the final suspensions (10-fold reduction) in comparison to that obtained by a conventional method. The method also recovered an average of 68.4% of cysts from 25-g lettuce samples and had a limit of detection (LOD) of 38 cysts. While the recovery of cysts by inertial separation was slightly lower, and the LOD slightly higher, than with the conventional method, the sample analysis time was greatly reduced, as there were far fewer background food particles interfering with the detection of cysts by immunofluorescence microscopy.  相似文献   

18.

Objective

The aim of this study was to evaluate a multiple immunoaffinity protein depletion (multiple affinity removal system, MARS) pre-treatment strategy with subsequent two-dimensional polyacrylamide gel electrophoresis (2D PAGE) and peptide mass finger printing analysis for the detection of ovarian cancer-associated plasma proteins.

Materials and Methods

Following immunoaffinity depletion, total plasma protein content was reduced by 84.2?±?1.8% (mean?±?SE, n?=?32). The number of proteins detected in the control and ovarian cancer groups was 349 and 357, respectively. This represented an increase in spot detection of almost twofold when compared to 2D PAGE displays of untreated plasma (174 spots). Of the proteins displayed, post-depletion, 300 (control) and 302 (ovarian cancer, OC) were common within each group. PDQuest analysis indicated that 109 protein spots were statistically different between the two groups and, of these, 59 exhibited greater than or equal to twofold difference in spot density (Student’s t test, p?=?0.01). Thirty-nine of these proteins were successfully identified with reliable confidence.

Results and Discussion

The data obtained in this study demonstrates that immunodepletion of plasma before 2D PAGE profiling have generated identifiable plasma proteins that are differentially expressed in the high-grade ovarian cancer sample set compared to controls. This approach, therefore, may be useful in identifying candidate biomarkers for inclusion in multi-marker tests for ovarian cancer that may exhibit greater sensitivity and specificity than those currently available. It was evident, however, from the predominant identification of host response proteins that immunodepletion did not generate sufficient levels of enrichment of lower abundance tumor-specific proteins to facilitate detection.  相似文献   

19.
A new method for electrophoretic retrieval of protein zones from Immobiline matrices is described, based on elution directly in a free liquid phase, rather than in ion-exchange beads or molecular sieves, as previously described. The chopped Immobiline gel is loaded on top of a 5% T stacking gel, 6-10 mm in height, and forced to transverse it and collect into a chamber, filled with 20% sucrose solution, closed on its anodic side by a dialysis sac. The transfer is practically quantitative, for most proteins, after 30-60 min of zone electrophoresis at 10 W (300 V potential differential). Recovery of protein mass is in general better than 90%, while for enzyme activity is in the range of 60-80%. For preserving enzyme integrity, the following precautions are recommended: short electrophoretic times; avoidance of anodic oxidation; chilling of the buffer in the anodic chamber; and use of low levels (2-5 mM) of the specific enzyme substrate throughout the entire electrophoretic system (cathode, anode and gel plug).  相似文献   

20.
Differences among techniques for high-abundant protein depletion   总被引:3,自引:0,他引:3  
The need to identify protein or peptide biomarkers via readily available biological samples like serum, plasma, or cerebrospinal fluid is often hindered by a few particular proteins present at relatively high concentrations. The ability to remove these proteins specifically, reproducibly, and with high selectivity is increasingly important in proteomic studies, and success in this procedure is leading to an ever-increasing list of lower abundant proteins being identified in these biological fluids. The current work addresses some of the potential problems in depleting proteins in typical biomarker studies, including nonspecific binding during depletion procedures and whether low molecular weight (LMW) species bind to the column in a so-called "sponge" effect caused by the ability of albumin or other high-abundant proteins to bind peptides or protein fragments. LC-MS/MS methods were applied to the comparative analysis of an IgG-based immunodepletion method and a Cibacron blue (CB)-dye-based method, for specificity of removing targeted proteins (binding fraction), as well as for assessing efficiency of target removal. This analysis was extended to examine the effects of repeated use of materials (cycles of binding and elution), in order to assess potential for carryover of one sample to the next. Capacity studies and efficiency of protein removal from the serum samples were followed for the IgG-based system using both immunochemical assays (ELISA) as well as LC-MS/MS methods. Additionally, the IgG-based system was further characterized for the removal of LMW polypeptides by nonspecific binding. We conclude that the IgG-based system provided effective removal of targeted proteins, with minimal carryover, high longevity, and minimal nonspecific binding. Significant differences are noted between the depletion techniques employed, and this should be considered based on the expectations set during experimental design.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号