首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A reversed-phase high-performance liquid chromatographic method for the determination of the enantiomers of atenolol in rat hepatic microsome has been developed. Racemic atenolol was extracted from alkalinized rat hepatic microsome by ethyl acetate. The organic layer was dried with anhydrous sodium sulfate and evaporated using a gentle stream of air. Atenolol racemic compound was derivatized with 2,3,4,6-tetra-O-acetyl-β- -glycopyranosyl isothiocyanate at 35°C for 30 min to form diastereomers. After removal of excess solvent, the diastereomers were dissolved in phosphate buffer (pH 4.6)–acetonitrile (50:30). The diastereomers were separated on a Shimadzu CLC-C18 column (10 μm particle size, 10 cm×0.46 cm I.D.) with a mobile phase of phosphate buffer–methanol–acetonitrile (50:20:30, v/v) at a flow-rate of 0.5 ml/min. A UV–VIS detector was operated at 254 nm. For each enantiomer, the limit of detection was 0.055 μg/ml (signal-to-noise ratio 3) and the limit of quantification (signal-to-noise ratio 10) was 0.145 μg/ml (RSD <10%). In the range 0.145–20 μg/ml, intra-day coefficients of variation were 1.0–7.0% and inter-day coefficients of variation were 0.4–16.5% for each enantiomer. The assay was applied to determine the concentrations of atenolol enantiomers in rat hepatic microsome as a function of time after incubation of racemic atenolol.  相似文献   

2.
Prednisolone, prednisolone acetate and prednisolone sodium phosphate are glucocorticoids used for ocular, anti-inflammatory therapy. A reversed-phase high-performance liquid chromatographic assay using ultraviolet detection has been developed that affords baseline resolution of the above analytes in balanced salt solutions and rabbit aqueous humor. The drugs can be quantified at 0.025–0.05 μg/ml in the above matrices; 6α-methylprednisolone is used as the internal standard. Both esters of prednisolone are vulnerable to chemical and enzymatic hydrolysis giving prednisolone. Analysis of aqueous humor samples shows prednisolone acetate penetrating/metabolizing primarly to prednisolone; prednisolone sodium phosphate penetrates the cornea giving the ester and alcohol.  相似文献   

3.
A high-performance liquid chromatographic procedure was developed for the determination of caffeine in various biologic fluids and coffee. A reversed-phase column and UV detection at 254 nm were used to obtain a sensitivity of 0.1 μg/ml caffeine in serum and saliva using a sample volume of 0.1 ml. Caffeine metabolites and commonly ingested xanthines do not interfere with the assay. The within-day coefficients of variation were 9.8 and 9.9% at plasma caffeine concentrations of 2 and 10 μg/ml, respectively. The day-to-day coefficients of variation were 6.8 and 6.6% at plasma caffeine concentrations of 2 and 10 μg/ml, respectively. Serum and saliva caffeine concentrations were determined following a single oral dose of coffee and an intravenous infusion of caffeine in one subject. Computer estimates of caffeine pharmacokinetic parameters in one subject are in excellent agreement with previously published values.  相似文献   

4.
We describe the first method for routine measurement of prednisone, prednisolone and 6β-hydroxyprednisolone concomitantly in urine. Urine (3 ml) is extracted with ethyl acetate, washed with base and separated by high-performance liquid chromatography on a silica column with a solvent system of hexane—diethyl ether—ethanol—tetrahydrofuran—glacial acetic acid (59.9:31:2.3:6.5:0.3, v/v). The steroids are detected at 254 nm. Because no conventional internal standard was found, 6β-[3H]hydroxycortisol and [3H]prednisolone are added to urine prior to extraction; 3H is monitored by a radioactivity detector coupled with the chromatograph. The assay exhibits linearity from 200 to 7500 ng and an inter-day variability of < 11.4% (C.V.).  相似文献   

5.
A rapid, specific, sensitive and economical method has been developed and validated for the determination of grepafloxacin in human plasma and urine. The assay consisted of reversed-phase HPLC with UV detection. Plasma proteins were removed by a fast and efficient procedure that has eliminated the need for costly extraction and evaporation. For the urine samples, the only required sample preparation was dilution. Separation was achieved on a reversed-phase TSK gel column with an isocratic mobile system. The method had a quantification limit of 0.05 μg/ml in plasma and 0.5 μg/ml in urine. The coefficients of variation (C.V.) were less than 4% for within- and between-day analyses. The method was successfully applied to a pharmacokinetic study, and was proved to be simple, fast and reproducible.  相似文献   

6.
In order to determine epirubicin and its metabolites at low concentrations (<38 ng/ml) in small plasma samples, a fast reliable method based on a precipitation pre-treatment and sensitive reversed-phase isocratic HPLC has been developed and validated for epirubicin in the range 5–100 ng/ml. The R.S.D. was 5–9% over this concentration range. For human serum containing 25 ng/ml of epirubicin, the inter- and intra-day variation was <10%. Recoveries of the metabolites epirubicinol, 7-deoxydoxorubicinone and 7-deoxydoxorubicinolone at 20 ng/ml ranged from 94–104%. The assay has been used to study human plasma samples taken during a 96-h infusion of epirubicin in a patient with multiple myeloma. The combined levels of the unseparated metabolites, epirubicin glucuronide and epirubicinol glucuronide, were semiquantitatively determined after treatment with β-glucuronidase. The metabolites epirubicinol and 7-deoxydoxorubicinolone, but not 7-deoxydoxorubicinone, were also detected and measured.  相似文献   

7.
A rapid and sensitive method for the assay of zonisamide in serum was developed using a solid-phase extraction technique followed by high-performance liquid chromatography. A 20-μl volume of human serum was first purified with a Bond-Elut cartridge column. Then, the methanol eluate was injected onto a reversed-phase HPLC column with a UV detector. The mobile phase was acetonitrile—methanol—distilled water (17:20:63, v/v) and the detection wavelength was 246 nm. The detection limit was 0.1 μg/ml in serum. The coefficients of variation were 4.2–5.6% and 5.1–9.1% for the within-day and between-day assays, respectively. This method can be used for clinical pharmacokinetic studies of zonisamide in serum even in infant patients with epilepsy.  相似文献   

8.
Methocarbamol enantiomers in rat and human plasma were quantified using a stereospecific high-performance liquid chromatographic method. Racemic methocarbamol and internal standard, (R)-(−)-flecainide, were isolated from plasma by a single-step extraction with ethyl acetate. After derivatization with the enantiomerically pure reagent (S)-(+)-1-(1-naphthyl)ethyl isocyanate, methocarbamol diastereomers and the (R)-flecainide derivative were separated on a normal-phase silica column with a mobile phase consisting of hexane—isopropanol (95:5, v/v) at a flow-rate of 1.6 ml/min. Ultraviolet detection was carried out at a wavelength of 280 nm. The resolution factor between the diastereomers was 2.1 (α = 1.24). An excellent linearity was observed between the methocarbamol diastereomers/internal standard derivative peak-area ratios and plasma concentrations, and the intra- and inter-day coefficients of variation were always <9.8%. The lowest quantifiable concentration was 0.5 μg/ml for each enantiomer (coefficients of variation of 9.8 and 8.8% for (S)- and (R)-methocarbamol, respectively), while the limit of detection (signal-to-noise ratio 3:1) was approximately 10 ng/ml. The assay was used to study the pharmacokinetics of methocarbamol enantiomers in a rat following intravenous administration of a 120 mg/kg dose of racemic methocarbamol and to evaluate plasma and urine concentrations in a human volunteer after oral administration of a 1000-mg dose of the racemate. The method is suitable for stereoselective pharmacokinetic studies in humans as well as in animal models.  相似文献   

9.
A sensitive and simple method is described for the selective determination in human plasma of α-amanitin, the most poisonous and prevalent toxin in the lethal fungi of species Amanita, using high-performance liquid chromatography with amperometric detection. After an extraction of plasma with disposable C18 silica cartridges, the extracts were separated by isocratic reversed-phase chromatography using a macroporous poly(styrene—divinylbenzene) column and a mobile phase of 0.05 M phosphate buffer—acetonitrile (91:9) at the apparent pH of 9.5. Amperometric detection was performed by applying an oxidation potential as low as +350 mV (vs. Ag/AgCl) to a glassy carbon electrode, in a thin-layer flow-cell. The linear range for α-amanitin was 3–200 ng/ml, and the relative limit of detection in plasma was 2 ng/ml at a signal-to-noise ratio of 2. The intra-assay precision was evaluated at levels of 10 and 200 ng/ml; the coefficients of variation were 4.5 and 2.6% (n=5), respectively. Inter-assay coefficients of variation were 6.5 and 4.2% (n=5) for the same concentrations of toxin. These analytical conditions have been chosen on the basis of a preliminary in batch cyclic voltammetric investigation of α-, β- and γ-amanitins, which has allowed their oxidation process to be clarified and the pH dependence of their oxidation potentials to be determined. All three amanitins are oxidized at the same potential values, and adsorption onto the electrode surface of both reactant and products was found in all cases. This adsorption did not affect the signal recorded for α- and γ-amanitins at the amperometric detector, and for β-amanitin a stronger adsorption for the anodic product was found, which leads to a marked positive shift of the potential required for the oxidation of this isomer in the amperometric detector cell.  相似文献   

10.
A selective high-performance liquid chromatographic (HPLC) assay for a sigma receptor antagonist, DuP 734 (I), in rat plasma has been developed. Compound I and internal standard, XC031 (I.S.), were first extracted from plasma into an ethyl acetate—toluene mixture (3:7, v/v) and then back-extracted into freshly prepared phosphoric acid (0.03 M). Separation of I and I.S. with no interference from endogenous substances was achieved on a reversed-phase octyl column and detection was by UV at 229 nm. The mobile phase consisted of acetonitrile—glacial acetic acid—triethylamine—0.05 M ammonium acetate (670:4:2:2000, v/v). Using 0.5 ml of rat plasma for extraction, the limit of quantitation was 43 ng/ml and the assay was linear from 43 to 8536 ng/ml. The intra- and inter-day coefficients of variation ranged from 0.7 to 3.0%, and from 1.4 to 14.5%, respectively, over the entire concentration range. The accuracy was within 16.1% of the spiked concentrations. I was stable in frozen plasma at −20°C for at least 68 days.  相似文献   

11.
Given the close resemblance of the ring A structure of prednisolone and prednisone on the one hand, and of androstadienedione on the other, the transformation of cortisol and cortisone into prednisolone and prednisone in cattle faeces was evaluated. A simple method that does not involve extraction but only the 1:100 dilution of cattle faeces, spiking with 400 ng/mL cortisol, cortisone or cortisol glucuronide and incubation of the suspension, was used. The analyses were performed by HPLC–MS3 to detect the supposed Δ1 dehydrogenation of the glucocorticoids. The decision limits (CCα) and detection capabilities (CCβ) were 2.0 and 3.0 ng/mL for cortisol, cortisone and prednisolone, 3.0 and 4.0 ng/mL for cortisol glucuronide and 7.0 and 10.0 ng/mL for prednisone, respectively. Intra-day and inter-day coefficients of variation (CV%), were 5.6–6.2 and 5.2–6.6 for cortisol glucuronide, cortisol, cortisone and prednisolone, and 16.0 and 16.2 for prednisone, respectively. The recoveries were in the range 110–143% for all analytes. Regression coefficients (R2) were in the range 0.996–0.999 for all analytes. The results show the hydrolysis of the conjugated form and the dehydrogenation in ring A in diluted faeces. It is therefore predicted that urine contaminated with faeces may be positive for prednisone and prednisolone in the same way as they are positive for boldenone, i.e. as a result of microbiological dehydrogenase activity on cortisol and cortisone.  相似文献   

12.
A high-performance liquid chromatographic method was developed for the determination in plasma (400-μl sample) of a vinca alkaloid, vinorelbine. The analysis was performed by using an octadecylsilane column and heptanesulfonic acid as ion-pairing agent. This method used a new internal standard, teniposide, that permitted a good compromise between sensitivity and retention times (10.6 and 15.5 min for teniposide and vinorelbine, respectively). After a liquid-liquid extraction with diethyl ether, the extracts were injected into a reversed-phase system. The extraction efficiency was approximately 80% for both vinorelbine and the internal standard. The mobile phase was phosphate buffer (pH 3)-acetonitrile-methanol (50:30:20, v/v/v). Using coulometric detection, the limit of detection in plasma (400 μl) was 1 ng.ml. The intra-assay coefficients of variation were 10.95, 3.80 and 5.71% for 5, 500 and 1000 ng/ml, respectively, and the inter-assay coefficients of variation were 20.14, 14.27 and 10.67% for 5, 500 and 1000 ng/ml, respectively. A linear response was observed for the plasma calibration graph in the ranges 2.5–50 and 50–1000 ng/ml. This method was used to follow the time course of the concentration of vinorelbine in rabbit plasma after a single intravenous dose of vinorelbine (30 mg/m2) and seems to be suitable for studying the pharmacokinetics of vinorelbine in rabbit.  相似文献   

13.
(1) The chemotactic activities of thromboxane B2 (TxB2, PGE2, PGF, the 15-oxo, 15-oxo-13,14-dihydro and 13,14-dihydro metabolites of PGE2, PGF, and a metabolite of TxB2 for polymorphonuclear leucocytes (PMN) have been investigated.(2) Thromboxane B2 increased the directional migrationm of rat peritoneal PMN at a concentration of 2.0 μg/ml and of human peripheral neutrophils at a concentration of 0.5 μg/ml.(3) Neither PGE2, PGF nor their metabolites showed chemotactic activity for rat peritoneal PMN.(4) PGF and 15-oxo-13,14-dihydro-thromboxane B2 showed no chemotactic activity for human peripheral PMN.(5) The possible role of thromboxane B2 in inflammation is discussed.  相似文献   

14.
A rapid and selective high-performance liquid chromatographic assay for determination of a new antimalarial drug (benflumetol, BFL) is described. After extraction with hexane-diethyl ether (70:30, v/v) from plasma, BFL was analysed using a C18 Partisil 10 ODS-3 reversed-phase stainless steel column and a mobile phase of acetonitrile-0.1 M ammonium acetate (90:10, v/v) adjusted to pH 4.9 with ultraviolet detection at 335 nm. The mean recovery of BFL over a concentration range of 50–400 ng/ml was 96.8±5.2%. The within-day and day-to-day coefficients of variation were 1.8–4.0 and 1.8–4.2%, respectively. The minimum detectable concentration in plasma for BFL was 5 ng/ml with a C.V. of less than 10%. This method was found to be suitable for clinical pharmacokinetic studies.  相似文献   

15.
A reversed-phase high-performance liquid chromatographic assay for the analysis of γ-carboxyglutamic acid (Gla) in urine and bone protein hydrolyzates is described. The method employs precolumn derivatization with o-phthalaldehyde and mercaptoethanol. Gla was quantified by reference to an internal standard (β-carboxyaspartic acid). The “within-run” coefficient of variation of the assay for Gla in urine was between 2.1 and 3.4%, and that for bone protein hydrolyzates was 3.2%. The “between-run” coefficient of variation ranged from 4.1 to 5.5%. There was good agreement between the measurement of urinary Gla by high-performance liquid chromatography and amino acid analyzer. Free Gla could not be detected in serum.  相似文献   

16.
In aquaculture, α-tocopheryl acetate (α-TA) is the main source of vitamin E used to fortify fish feed. α-TA in fish is often determined indirectly, i.e., by alkaline hydrolysis, followed by quantitation of “total α-tocopherol” (α-T) and subtraction of the natively present α-T. The aim of this study was to develop an HPLC method for the simultaneous quantitative determination of α-TA and free tocopherols in aquatic organisms and fish feed. The assay consists of a simple extraction with methanol containing butylhydroxytoluene (BHT) as an antioxidant, followed by reversed-phase chromatography with consecutive UV and fluorescence detection of α-TA and tocopherols, respectively. The peak of the internal standard tocol in the fluorescence trace was used for quantitation. Linearity was achieved over the range of 0.2 to 4.2 μg α-TA per ml extract of Artemia nauplii, which would correspond to 30.7 to 614.4 μg/g dry mass. The within-run coefficient of variation was 1.9% at a level of 310 μg/g dry mass. The recovery of α-TA ranged from 97.7 to 100.8% (concentration=2.1 and 20.5 μg/ml, n=6). The detection limit was about 7 ng and the quantification limit on spiked samples was 0.2 μg/ml. This method was routinely applied to determine α-TA and α-, γ- and δ-tocopherol (α-T, γ-T, δ-T) simultaneously in Artemia, fish feed, shrimp eggs and various other aquatic organisms.  相似文献   

17.
A rapid, sensitive and specific high-performance liquid chromatographic (HPLC) assay was developed and validated for the measurement of (−)-2′-deoxy-3′-thiacytidine (3TC) in human serum. The method included precipitation of serum proteins by trichloroacetic acid (20%, w/v) treatment followed by centrifugation. The resulting supernatant was directly injected and 3TC was isocratically chromatographed on a reversed-phase C18 column using a mixture of phosphate buffer and methanol (88.3:11.7, v/v) and monitored at 280 nm. The limit of quantitation was 20 ng/ml using 100 μl of serum. The standard curve was linear within the range of 20–10 000 ng/ml. Replicate analysis of three quality control samples (40–1500 ng/ml) led to satisfactory intra- and itner-assay precision (coefficient of variation from 3.0 to 12.9%) and accuracy (deviation from −6.3 to 9.7%). Moreover, sample treatment processes including human immunodeficiency virus (HIV) heat-inactivation, exposure at room temperature and freezing-thawing cycles did not influence the stability of the analyte. This assay was successfully applied to the determination of 3TC serum levels in HIV-infected patients. In addition, preliminary results indicated that this procedure may also be extended to the measurement of 3TC in human plasma and urine.  相似文献   

18.
CPT-11 {I; 7-ethyl-10-[4-(1-piperidino)-1-piperidino]carbonyloxycamptothecin} is a new anticancer agent currently under clinical development. A sensitive high-performance liquid chromatographic assay suitable for the simultaneous determination of I and its active metabolite SN-38 (II) in human plasma, and their preliminary clinical pharmacokinetics, are described. Plasma samples were processed using a solid-phase (C18) extraction step allowing mean recoveries of I, II and the internal standard camptothecin (III) of 84, 99 and 72%, respectively. The extracts were chromatographed on a C18 reversed-phase column with a mobile phase composed of acetonitrile, phosphate buffer and heptanesulphonic acid, with fluorescence detection. The calibration graphs were linear over a wide range of concentrations (1 ng/ml–10 μg/ml), and the lower limit of determination was 1 ng/ml for both I and II. The method showed good precision: the within-day relative standard deviation (R.S.D.) (5–1000 ng/ml) was 13.0% (range 4.9–19.4%) for I and 12.8% (6.7–19.1%) for II; the between-day R.S.D. (5–10 000 ng/ml was 7.9% (5.4–17.5%) for I and 9.7% (3.5–15.1%) for II. Using this assay, plasma pharmacokinetics of both I and II were simultaneously determined in three patients receiving 100 mg/m2 I as a 30-min intravenous infusion. The mean peak plasma concentration of I at the end of the intravenous infusion was 2400 ± 285 ng/ml (mean ± standard error of the mean). Plasma decay was triphasic with half-lives α, β and γ of 5.4 ± 1.8 min, 2.5 ± 0.5 h and 20.2 ± 4.6 h, respectively. The volume of distribution at steady state was 105 ± 15 l/m2, and the total body clearance was 12.5 ± 1.9 l/h · m2. The maximum concentrations of the active metabolite II reached 36 ± 11 ng/ml.  相似文献   

19.
This paper describes a high-performance liquid chromatographic method with ultraviolet absorbance detection at 304 nm for the determination of 6-chloro-5-(1-naphthyloxy)-2-methylthio benzimidazole (αBIOF10) — a new fasciolicide agent — and its sulphoxide (SOαBIOF10), in plasma and urine. It requires 2 ml of biological fluid, an extraction using Sep-Pak cartridges, and methanol for drug elution. Analysis is performed on a μBondapak C18 (10 μm) column, using methanol–acetonitrile–water (40:30:30, v/v) as the mobile phase. Results showed that the assay is sensitive: 12 ng/ml for αBIOF10 and SOαBIOF10 in plasma and 3.6 ng/ml for both compounds in urine. The response was linear between 0.195 and 12.5 μg/ml. Maximum intra-day coefficient of variation was 5.3%. Recovery obtained was 97.8% for both αBIOF10 and SOαBIOF10. In urine, recovery was 99.6% and 93.1% for αBIOF10 and SOαBIOF10 respectively. The method was used to perform a preliminary pharmacokinetic study in two sheep and was found to be satisfactory.  相似文献   

20.
A sensitive and specific liquid chromatographic–mass spectrometric assay has been developed for the determination of 22-oxacalcitriol (OCT), which is a new analog of 1α,25-dihydroxyvitamin D3. The analyte was isolated from serum by two solid-phase extraction steps on a C18 cartridge and NH2 cartridge. The recovery of OCT through two extraction steps was more than 90%. A related substance (ED-94), i.e. OCT with the side-chain shortened by one carbon, was used as an internal standard. Extracts were chromatographed on a C18 reversed-phase column interfaced to the electrospray ionization source. The mass spectrometer was operated in the positive-ion mode of selected reaction monitoring. The chromatographic run-time for one injection was less than 6 min. The intra- and inter-assay coefficients of variation for the lowest concentration examined (30 pg ml−1) were 9.83 and 10.67, respectively. And the analytical recovery of OCT added to serum was quantitative. Assay linearity was obtained in the range of 20–640 pg ml−1.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号