首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.

Background

The objective of this study was to evaluate the imaging characteristics of pulmonary artery sarcoma (PAS) on pulmonary artery computed tomography angiography (PACTA) that can be used to differentiate between PAS and pulmonary thromboembolic diseases, including chronic thromboembolic pulmonary hypertension (CTEPH) and acute pulmonary embolism (APE).

Methods

The clinical data and imaging characteristics of 12 patients with PAS, 156 patients with CTEPH, and 426 patients with APE who were treated at Beijing Anzhen Hospital from January 2007 to August 2013 were retrospectively analyzed. All patients underwent PACTA before treatment, and the diagnoses of PAS and CTEPH were all confirmed by surgical biopsy.

Results

All 12 PAS patients were initially misdiagnosed and received inappropriate thrombolytic and/or anticoagulant therapy before they were referred for surgical intervention. The mean time from PACTA to surgical intervention was 5.5±3.7 months (range 2–11 months). On PACTA, the PAS lesion always eclipsed the wall of the pulmonary artery before infiltrating outside the pulmonary artery, which was termed the wall eclipsing sign. This sign was observed in all PAS patients but was not observed in any CTEPH or APE patients.

Conclusions

PAS is a rare neoplasm with a poor prognosis, and is easily misdiagnosed as thromboembolic disease. The wall eclipsing sign on PACTA is pathognomonic for PAS, and patients with this sign should be investigated to confirm the diagnosis and should undergo surgical intervention as soon as possible, rather than receiving thrombolytic or anticoagulant therapy.  相似文献   

2.
The aim of our study was to compare the rapid neurological improvement after intravenous recombinant tissue-type plasminogen activator (rtPA) in patients with proximal hyperdense middle cerebral artery sign (p-HMCAS) to those without the sign and those with the distal hyperdense middle cerebral artery sign (d-HMCAS). Admission and 24 hour non-contrast CT scans of 120 patients with middle cerebral artery (MCA) territory stroke who were treated with intravenous rtPA were assessed for the presence of p-HMCAS and d-HMCAS. The sign was classified according to the site of occlusion. Rapid neurological improvement was defined as ≥50% improvement in the NIHSS score at 24 hours after thrombolysis. Rapid neurological recovery after thrombolysis was assessed and compared between the subgroups. Rapid neurological recovery was less common in the pooled group of patients with either p-HMCAS or d-HMCAS than those without the sign (p<0.01). Patients with p-HMCAS were less likely to have rapid neurological recovery than those with d-HMCAS (p<0.01). However, there was no difference in early neurological recovery between patients with d-HMCAS and those without any hyperdense sign. Our study showed that poor neurological recovery post rtPA was confined to p-HMCAS and not to d-HMCAS, indicating that these signs have quite different prognostic significance.  相似文献   

3.
目的:分析冠状动脉解剖变异的CT血管造影(computed tomography angiography,CTA)影像特征。方法:回顾分析2010年6月到2014年4月间PACS存储的12326例心脏CTA图像资料,记录解剖变异冠状动脉的名称、开口起源位置、数目、行程状态及终止部位表现及其与毗邻结构的关系。结果:共有700例心脏有冠状动脉解剖变异,以冠状动脉开口起源异常最多见,共622例(622/12326,5.05%),其中左和右冠状动脉开口高位350例(350/12326,2.84%),左和右冠状动脉开口于对侧窦166例(166/12326,1.35%),冠状动脉双开口70例(70/12326,0.57%),左和右冠状动脉开口于窦间36例(36/12326,0.29%);其次为数目异常29例(29/12326,0.24%),包括左、右单支冠状动脉19例(19/12326,0.15%)和冠状动脉分支(LCx)缺如10例(10/12326,0.08%);冠状动脉终止异常(冠脉动脉-动脉圆锥和/或肺动脉瘘)29例(29/12326,0.24%)。VR是显示冠状动脉解剖变异最重要的后处理方法。结论:冠状动脉解剖变异CTA表现复杂多样,心脏CTA能够准确显示冠状动脉解剖变异种类及其毗邻关系。  相似文献   

4.
The aim of this study was to investigate whether brachial-ankle pulse wave velocity (baPWV) is associated with the severity of coronary artery disease (CAD) assessed by coronary computed tomography angiography (CCTA), and to evaluate baPWV as a predictor of obstructive CAD on CCTA. A total of 470 patients who underwent both baPWV and CCTA were included. We evaluated stenosis degree and plaque characteristics on CCTA. To estimate the severity of CAD, we calculated the number of segment with plaque (segment involvement score; SIS), stenosis degree-weighted plaque score (segment stenosis score; SSS), and coronary artery calcium score (CACS). The mean baPWV was 1,485 ± 315 cm/s (range, 935-3,175 cm/s). Non-obstructive (stenosis < 50%) and obstructive (stenosis ≥ 50%) CAD was found in 129 patients (27.4%) and 144 (30.6%), respectively. baPWV in patients with obstructive CAD was higher than that of patients with non-obstructive (1,680 ± 396 cm/s versus 1,477 ± 244 cm/s, P < 0.001) or no CAD (1,680 ± 396 cm/s versus ± 196 1,389 cm/s, P < 0.001). baPWV showed significant correlation with SSS (r = 0.429, P < 0.001), SIS (r = 0.395, P < 0.001), CACS (r 0.346, P < 0.001), and the number of segment with non-calcified plaque (r 0.092, P = 0.047), mixed plaque (r = 0.267, P < 0.001), and calcified plaque (r = 0.348, P < 0.001), respectively. The optimal baPWV cut-off value for the detection of obstructive CAD was 1,547 cm/s. baPWV ≥ 1,547 cm/s was independent predictor for the obstructive CAD. In conclusion, baPWV is well correlated with the severity of CAD evaluated by CCTA. baPWV has the potential to predict severity of coronary artery atherosclerosis.  相似文献   

5.

Objective

Aortic unfolding occurs with aging and reflects proximal aortic dilation, aortic arch widening, and decreased curvature. This study 1) evaluated the relationship between aortic unfolding measured using non-contrast cardiac-gated computed tomography (CT) and age, 2) assessed factors influencing aortic unfolding, and 3) determined the association of this measurement with coronary artery calcium (CAC) score.

Methods

We reviewed the charts of 219 subjects (142 men, 77 women; mean age 54.2±9.3 years) who underwent coronary artery calcium scanning during routine health screening from December 2010 to May 2011. Multivariate regression analysis according to cardiovascular risk factors was performed. We also analyzed the relationship between aortic unfolding measurements and CAC score using stepwise multiple linear regression.

Results

Mean aortic unfolding was 103.7±13.9 mm (men, 106.5±13.5 mm; women, 98.4±12.9 mm). Age, body surface area, and hypertension were exclusively associated with aortic unfolding. The association between aortic unfolding and CAC score was significant after adjustment for age and gender (β = 1.89, p = 0.017) and for Framingham risk score (β = 2.83, p<0.001).

Conclusions

Aortic unfolding defined by measuring aortic width was a reproducible and practical method with non-contrast cardiac CT and associated with age, body surface area, and hypertension. CAC score, a well-established surrogate marker of cardiovascular disease, is positively associated with aortic unfolding. Further study to evaluate aortic unfolding as a potential predictor of cardiovascular risk is warranted.  相似文献   

6.

Background & Aims

The amount of drug-loaded lipiodol in an HCC tumor post-transarterial chemoembolization (TACE) correlates with the risk of local tumor recurrence. Lipiodol enhancement of a tumor on conventional CT, measured in Hounsfield units (HU), can predict tumor response. Here we investigate whether cone-beam CT (CBCT) can also be used to predict tumor response, providing the benefit of being able to optimize the patient’s treatment plan intra-procedurally.

Methods

A total of 82 HCC nodules (82 patients), ≤5 cm in diameter, were treated with balloon-occluded TACE using miriplatin between December 2013 and November 2014. For each patient, both CBCT and conventional CT images were obtained post-TACE. The degree of correlation between CBCT and conventional CT was determined by comparing identical regions of interest for each imaging modality using pixel values.

Results

The pixel values from conventional CT and CBCT were highly correlated, with a Pearson correlation coefficient of 0.912 (p<0.001). The location of the nodules within the liver did not affect the results; the correlation coefficient was 0.891 (p<0.001) for the left lobe and 0.926 (p<0.001) for the right lobe. The mean pixel value for conventional CT was 439 ± 279 HU, and the mean pixel value for CBCT was 416 ± 311 HU.

Conclusions

CBCT may be used as a substitute for conventional CT to quantitatively evaluate the amount of drug-loaded lipiodol within an HCC nodule and, hence, the efficacy of TACE treatment. The major benefit of using CBCT is the ability to predict the likelihood of local recurrence intra-procedurally, enabling subsequent treatment optimization.  相似文献   

7.
8.

Background and Aims

Previous studies have shown impaired cerebral autoregulation (CA) in carotid and middle cerebral artery (MCA) stenosis/occlusion. Little is known about CA in patients with basilar artery (BA) stenosis. We therefore investigated dynamic CA patterns in BA stenosis using transfer function analysis (TFA).

Methods

We measured spontaneous oscillations of blood flow velocity (CBFV) in the right posterior cerebral artery (PCA), and left MCA and mean arterial pressure (ABP) continuously in 25 patients with BA stenosis (moderate n=16 with 50-69% occlusion and severe n=9 with ≥70% occlusion) and 22 healthy volunteers in supine position during 6 circles per minute deep breath. Analysis was based on the ‘black-box’ model of transfer function deriving phase and gain in both PCA and MCA.

Results

Though changes of phase shift and gain between the patients and healthy controls were observed in MCA, the differences are however not significant. Phase shift in PCA was significantly decreased in severe stenosis when comparing with healthy controls and moderate stenosis (4.2±34.2° VS 41.1±40.4°, 4.2±34.2° VS 34.2±27.2°, both p<0.05), whilst the gain in PCA is increased for moderate BA stenosis and decreased for severe BA stenosis. Furthermore, we found that phase shift were almost abolished in patients with ischemic stroke who developed unfavorable clinical outcome (mRs>2) on the 90 days after stroke onset.

Conclusion

Dynamic CA in PCA reduces in patients with severe BA stenosis and those with ischemic stroke who present poor outcome in 90 days after stroke onset. Phase shift might be a sensitive index prompting impaired CA in posterior circulation.  相似文献   

9.
Since the initial publication of the International Study of Unruptured Intracranial Aneurysms (ISUIA), management of unruptured intracranial aneurysms has been mainly based on the size of the aneurysm. The contribution of morphological characteristics to treatment decisions of unruptured aneurysms has not been well studied in a systematic and location specific manner. We present a large sample of basilar artery tip aneurysms (BTA) that were assessed using a diverse array of morphological variables to determine the parameters associated with ruptured aneurysms. Demographic and clinical risk factors of aneurysm rupture were obtained from chart review. CT angiograms (CTA) were evaluated with Slicer, an open source visualization and image analysis software, to generate 3-D models of the aneurysms and surrounding vascular architecture. Morphological parameters examined in each model included aneurysm volume, aspect ratio, size ratio, aneurysm angle, basilar vessel angle, basilar flow angle, and vessel to vessel angles. Univariate and multivariate analyses were performed to determine statistical significance. From 2008–2013, 54 patients with BTA aneurysms were evaluated in a single institution, and CTAs from 33 patients (15 ruptured, 18 unruptured) were available and analyzed. Aneurysms that underwent reoperation, that were associated with arteriovenous malformations, or that lacked preoperative CTA were excluded. Multivariate logistic regression revealed that a larger angle between the posterior cerebral arteries (P1-P1 angle, p = 0.037) was most strongly associated with aneurysm rupture after adjusting for other morphological variables. In this location specific study of BTA aneurysms, the larger the angle formed between posterior cerebral arteries was found to be a new morphological parameter significantly associated with ruptured BTA aneurysms. This is a physically intuitive parameter that can be measured easily and readily applied in the clinical setting.  相似文献   

10.
赵君秋 《蛇志》2005,17(2):81-83
目的观察纤溶酶与盐酸丁咯地尔联合治疗椎-基底动脉供血不足的临床疗效。方法治疗组50例应用纤溶酶200U,每天1次,连续用10天;同时应用盐酸丁咯地尔100mg,每天1次,连续应用15天。对照组48例应用盐酸丁咯地尔100mg,每天1次,连续15天。观察治疗前后血液流变学指标变化并评价其疗效。结果治疗组总有效率90.0%,对照组总有效率62.5%,两组差异显著(P<0.01)。治疗组在改善全血粘度、血浆粘度、增加红细胞变形指数、降低纤维蛋白原方面优于对照组(P<0.05);治疗组患者的凝血酶原时间延长(P<0.05),但不影响出凝血时间(P>0.05)。结论纤溶酶与丁咯地尔联合应用比单纯应用丁咯地尔治疗椎-基底动脉供血不足的疗效显著。  相似文献   

11.
12.
Neonatal skull anatomy and its evolution have received less attention with respect to the brain anatomy in neuroscience and neuroanatomy studies. Meanwhile, their influence on normal brain development and their impact on the results of functional brain studies have been demonstrated by several researches. Such disesteem is due to the weak appearance of the cranial bones, fontanels and sutures in images acquired by MRI which presents actually the only available aperture for observing the neonatal head volume in details. This paper presents an unprecedented retrospective CT-based study on modeling the neonatal skull and its development during the first weeks of life in a standard space defined by the available neonatal MRI model. We create two neonatal head atlases for the age ranges of 39-40 and 41-42 week's gestational age using symmetric group-wise normalization method. The created atlases allow direct observation of ossification patterns and precise three-dimensional measurement of anatomical features from neonatal skull during development. Development of the neonatal skull has been examined here using nineteen CT scans of neonates with two-week gestational age ranges of 39 to 40 and 41 to 42. Deformation-based morphometry method is applied with the use of Jacobian determinant maps to identify growth patterns and observe ossification during specified time interval. Precise three-dimensional measurements of anterior fontanel size, scalp eliminated head circumference and the area corresponding to the fontanel-sutures were performed by extracting fontanels and sutures.  相似文献   

13.

Background

Factors determining the shape of the human rib cage are not completely understood. We aimed to quantify the contribution of anthropometric and COPD-related changes to rib cage variability in adult cigarette smokers.

Methods

Rib cage diameters and areas (calculated from the inner surface of the rib cage) in 816 smokers with or without COPD, were evaluated at three anatomical levels using computed tomography (CT). CTs were analyzed with software, which allows quantification of total emphysema (emphysema%). The relationship between rib cage measurements and anthropometric factors, lung function indices, and %emphysema were tested using linear regression models.

Results

A model that included gender, age, BMI, emphysema%, forced expiratory volume in one second (FEV1)%, and forced vital capacity (FVC)% fit best with the rib cage measurements (R2 = 64% for the rib cage area variation at the lower anatomical level). Gender had the biggest impact on rib cage diameter and area (105.3 cm2; 95% CI: 111.7 to 98.8 for male lower area). Emphysema% was responsible for an increase in size of upper and middle CT areas (up to 5.4 cm2; 95% CI: 3.0 to 7.8 for an emphysema increase of 5%). Lower rib cage areas decreased as FVC% decreased (5.1 cm2; 95% CI: 2.5 to 7.6 for 10 percentage points of FVC variation).

Conclusions

This study demonstrates that simple CT measurements can predict rib cage morphometric variability and also highlight relationships between rib cage morphometry and emphysema.  相似文献   

14.
目的:研究320排CT冠脉造影对分析冠状动脉轻度及重度狭窄患者斑块成分的价值。方法:2011年4月-2012年5月间我院1132例(62±12岁,42%女性)冠心病患者行320排CT冠状动脉造影检查,依据美国心脏协会16分段标准,分析每一例患者每一节段血管狭窄程度及斑块性质,CT斑块分型如下:Ⅰ型为钙化斑块,Ⅱ型为钙化为主的混合斑块,Ⅲ型为非钙化为主的混合斑块,Ⅳ型为非钙化斑块。比较不同狭窄程度组斑块类型差别。结果:共363例为冠脉血管正常人群,冠状动脉狭窄患者共769例,其中管腔狭窄程度<50%的轻度人群为367例,重度狭窄组(≥50%)为402例。重度狭窄患者组冠脉血管混合斑块数量较多,而非钙化斑块相对较少(Ⅰ~Ⅳ型斑块所占比例分别为22%,,39%,21%,18%),轻度狭窄患者组各斑块所占比例分别为29%,29%,26%,16%(p=0.006)。结论:随着冠状动脉狭窄程度的不同,冠状动脉粥样硬化斑块的类型也不尽相同,重度狭窄人群组中混合斑块较多而非钙化斑块较少。320排CT冠脉造影可对冠状动脉斑块成分进行分析。  相似文献   

15.
The purpose of the study presented here was to investigate the manufacturability of human anatomical models from Computed Tomography (CT) scan data via a 3D desktop printer which uses fused deposition modelling (FDM) technology. First, Digital Imaging and Communications in Medicine (DICOM) CT scan data were converted to 3D Standard Triangle Language (STL) format by using InVaselius digital imaging program. Once this STL file is obtained, a 3D physical version of the anatomical model can be fabricated by a desktop 3D FDM printer. As a case study, a patient’s skull CT scan data was considered, and a tangible version of the skull was manufactured by a 3D FDM desktop printer. During the 3D printing process, the skull was built using acrylonitrile-butadiene-styrene (ABS) co-polymer plastic. The printed model showed that the 3D FDM printing technology is able to fabricate anatomical models with high accuracy. As a result, the skull model can be used for preoperative surgical planning, medical training activities, implant design and simulation to show the potential of the FDM technology in medical field. It will also improve communication between medical stuff and patients. Current result indicates that a 3D desktop printer which uses FDM technology can be used to obtain accurate anatomical models.  相似文献   

16.

Purpose

Despite recommendations for 99mTc-tetrofosmin dual tracer imaging for hyperparathyroidism in current guidelines, no report was published on dual-isotope 99mTc-tetrofosmin and 123I sodium iodide single-photon-emission-computed-tomography (SPECT). We evaluated diagnostic accuracy and the impact of preoperative SPECT on the surgical procedures and disease outcomes.

Methods

Analysis of 70 consecutive patients with primary hyperparathyroidism and 20 consecutive patients with tertiary hyperparathyroidism. Imaging findings were correlated with surgical results. Concomitant thyroid disease, pre- and postoperative laboratory measurements, histopathological results, type and duration of surgery were assessed.

Results

In primary hyperparathyroidism, SPECT had a sensitivity of 80% and a positive predictive value of 93% in patient-based analysis. Specificity was 99% in lesion-based analysis. Patients with positive SPECT elicit higher levels of parathyroid hormone and higher weight of resected parathyroids than SPECT-negative patients. Duration of parathyroid surgery was on average, approximately 40 minutes shorter in SPECT-positive than in SPECT-negative patients (89±46 vs. 129±41 minutes, p=0.006); 86% of SPECT-positive and 50% of SPECT-negative patients had minimal invasive surgery (p = 0.021). SPECT had lower sensitivity (60%) in patients with tertiary hyperparathyroidism; however, 90% of these patients had multiple lesions and all of these patients had bilateral lesions.

Conclusion

Dual-isotope SPECT with 99mTc-tetrofosmin and 123I sodium iodide has a high diagnostic value in patients with primary hyperparathyroidism and allows for saving of operation time. Higher levels of parathyroid hormone and higher glandular weight facilitated detection of parathyroid lesion. Diagnostic accuracy of preoperative imaging was lower in patients with tertiary hyperparathyroidism.  相似文献   

17.
X-ray computed tomography (XCT) has been shown to be an effective imaging technique for a variety of materials. Due to the relatively low differential attenuation of X-rays in biological tissue, a high density contrast agent is often required to obtain optimal contrast. The contrast agent, iodine potassium iodide (), has been used in several biological studies to augment the use of XCT scanning. Recently was used in XCT scans of animal hearts to study cardiac structure and to generate 3D anatomical computer models. However, to date there has been no thorough study into the optimal use of as a contrast agent in cardiac muscle with respect to the staining times required, which has been shown to impact significantly upon the quality of results. In this study we address this issue by systematically scanning samples at various stages of the staining process. To achieve this, mouse hearts were stained for up to 58 hours and scanned at regular intervals of 6–7 hours throughout this process. Optimal staining was found to depend upon the thickness of the tissue; a simple empirical exponential relationship was derived to allow calculation of the required staining time for cardiac samples of an arbitrary size.  相似文献   

18.

Purpose

Scatter is a very important artifact causing factor in dental cone-beam CT (CBCT), which has a major influence on the detectability of details within images. This work aimed to improve the image quality of dental CBCT through scatter correction.

Methods

Scatter was estimated in the projection domain from the low frequency component of the difference between the raw CBCT projection and the projection obtained by extrapolating the model fitted to the raw projections acquired with 2 different sizes of axial field-of-view (FOV). The function for curve fitting was optimized by using Monte Carlo simulation. To validate the proposed method, an anthropomorphic phantom and a water-filled cylindrical phantom with rod inserts simulating different tissue materials were scanned using 120 kVp, 5 mA and 9-second scanning time covering an axial FOV of 4 cm and 13 cm. The detectability of the CT image was evaluated by calculating the contrast-to-noise ratio (CNR).

Results

Beam hardening and cupping artifacts were observed in CBCT images without scatter correction, especially in those acquired with 13 cm FOV. These artifacts were reduced in CBCT images corrected by the proposed method, demonstrating its efficacy on scatter correction. After scatter correction, the image quality of CBCT was improved in terms of target detectability which was quantified as the CNR for rod inserts in the cylindrical phantom.

Conclusions

Hopefully the calculations performed in this work can provide a route to reach a high level of diagnostic image quality for CBCT imaging used in oral and maxillofacial structures whilst ensuring patient dose as low as reasonably achievable, which may ultimately make CBCT scan a reliable and safe tool in clinical practice.  相似文献   

19.

Objectives

To investigate the frequency of aortic calcifications at the outer edge of the false lumen and the frequency of fully circular aortic calcifications in a consecutive series of patients with aortic dissection who underwent contrast-enhanced CT.

Methods

The study population compromised of 69 consecutive subjects aged 60 years and older with a contrast-enhanced CT scan demonstrating an aortic dissection. All CT scans were evaluated for the frequency of aortic calcifications at the outer edge of the false lumen and the frequency of fully circular aortic calcifications by two experienced observers. Between observer reliability was evaluated by using Cohen’s Kappa. Differences between groups were tested using unpaired T test and Chi-square test.

Results

Presumed media calcifications were observed in 22 (32%) patients of 60 years and older and were found more frequently in chronic aortic dissection (N = 12/23, 52%) than in acute aortic dissection (N = 10/46, 22%).

Conclusion

As the intima has been torn away by the aortic dissection it is highly likely that CT scans can visualize the calcifications in the tunica media of the aorta.  相似文献   

20.
Objective: Computed tomography (CT) is a common research procedure for measuring abdominal fat distribution, but little is written about the software used to analyze images. Our objective was to compare in‐house and commercially available software for quantitative measurement of abdominal fat distribution. In the process, we encountered some unexpected problems. Research Methods and Procedures: A total of 123 volunteers had single‐slice abdominal CT images taken that were used to evaluate various aspects of the commercial image analysis program. Results: The agreement between the commercial and in‐house programs was excellent (r = 0.996, p < 0.00, 001) for both total and intraabdominal fat, and we were able to reduce between‐observer variability in measured fat areas through the use of statistical handling of region of interest information. We also noted that intracolonic contents sometimes had the same Hounsfield units as adipose tissue. We analyzed single‐slice CT images from 50 volunteers to determine the potential impact of this effect on visceral fat area; the overestimate of visceral fat area was 19 ± 22% (maximum, 112% overestimate). The commercial program could prevent this error, whereas our in‐house program could not. Discussion: We concluded that a readily available commercial image analysis program compares well with a previously validated in‐house program and that it offers some advantages with respect to preventing overestimation of pixels as visceral fat.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号