首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A high-performance liquid chromatography (LC-MS) method has been developed and validated for the determination of dexamethasone in dried blood spot (DBS) samples. For the preparation of DBS samples whole blood spiked with analyte was used to produce 30μl blood spots on specimen collection cards. An 8mm disc was cut from the DBS sample and extracted using a combination of methanol: water (70:30, v/v) containing the internal standard, triamcinolone acetonide. Extracts were centrifuged and chromatographic separation was achieved using a Zorbax Eclipse Plus C18 column using gradient elution with a mobile phase of acetonitrile and water with formic acid at a flow rate of 0.2ml/min. LC-MS detection was conducted with single ion monitoring using target ions at m/z 393.1 for dexamethasone and 435.1 for the internal standard. The developed method was linear within the tested calibration range of 15-800ng/ml. The overall extraction recovery of dexamethasone from DBS samples was 99.3% (94.3-105.7%). The accuracy (relative error) and precision (coefficient of variation) values were within the pre-defined limits of ≤15% at all concentrations. Factors with potential to affect drug quantification measurements such as blood haematocrit, the volume of blood applied onto the collection card and spotting device were investigated. Although a haematocrit related effect was apparent, the assay accuracy and precision values remained within the 15% variability limit with fluctuations in haematocrit of ±5%. Variations in the volume of blood spotted did not appear to affect the performance of the developed assay. Similar observations were made regarding the spotting device used. The methodology has been applied to determine levels of dexamethasone in DBS samples collected from premature neonates. The measured concentrations were successfully evaluated using a simple 1-compartment pharmacokinetic model. Requiring only a microvolume (30μl) blood sample for analysis, the developed assay is particularly suited to pharmacokinetic studies involving paediatric populations.  相似文献   

2.
Routine incorporation of blood-based biomarker measurements in population studies has been hampered by challenges in obtaining samples suitable for biomarker assessment outside of laboratory settings. Here, we assessed the suitability of venous blood left unprocessed for 4, 24, or 48 hours post-collection at either room temperature or 4°C for quantification of two biomarkers, Interleukin-6 (IL-6) and C-reactive protein (CRP). Blood samples were collected in both K2EDTA tubes and a dedicated plasma-preservation tube, P100. Dried blood spot (DBS) samples from the same subjects were also collected in order to compare delayed-processing plasma performance against a popular alternative collection method. We found that K2EDTA mean plasma concentrations of both IL-6 and CRP were not significantly different from concentrations in plasma processed immediately; this was observed for tubes stored up to 48 hours pre-processing at either temperature. Concentrations of IL-6 measured in P100 tubes showed significant time-dependent increases when stored at room temperature; otherwise, levels of IL-6 and CRP were similar to those found in samples processed immediately. Levels of CRP in DBS were correlated with plasma CRP levels, even when pre-processed blood was stored for up to 48 hours. These data indicate that plasma is suitable for IL-6 and CRP estimation under data collection conditions that involve processing delays.  相似文献   

3.
Dried blood spots (DBSs) technology was evaluated in an assay for the quantitation of dextromethorphan (DM) and its metabolite, dextrorphan (DT), in human whole blood using high performance liquid chromatography with tandem mass spectrometry method (LC–MS/MS). Both the parent drug and metabolite were spiked in the blood matrix and subsequently allowed to dry on a specimen collection card. The dried blood spots were removed using a manual punch and then extracted into methyl tert-butyl ether (MTBE). The organic supernatant was transferred and evaporated and the residue was reconstituted in 20% acetonitrile. The overall method recovery of DM and DT was 87.8% and 95.4%, respectively. The assay was linear over the concentration range of 0.2–200 ng/mL for both analytes. Several factors that potentially affect DBS assay quantitation were investigated, such as punch size, DBS sample punch-out location, and the volume of the blood sample pipetted on the specimen collection cards. The study determined that punch size does not affect assay quantitation accuracy. Indeed, a larger punch size increases the sensitivity due to the larger sampled blood spots. Sampling from different location on the specimen collection cards shows no significant variation for both drugs. The study also shows that acceptable results can be achieved with some variation of the sample volume, which allows a simple blood sampling procedure at the test sites. To achieve the similar lower limit of quantitation (LLOQ) as the plasma assay, several blood spots at the same concentration level were stacked together and extracted. Bioanalytical assays using the DBS technique are promising given the advantages of the method over the plasma assay.  相似文献   

4.
A high-performance liquid chromatography-tandem mass spectrometric (LC-MS/MS) method has been developed and validated for the quantitative analysis of NIM811, a cyclophilin inhibitor, in human dried blood spot (DBS) samples, which were produced by spotting 20 μl whole blood onto FTA cards. A 3mm disc was cut from the DBS samples and extracted using methanol, followed by liquid-liquid extraction with MTBE. The reconstituted extracts were chromatographed using a Halo C(18) column and gradient elution for MS/MS detection. The possible impact of hematocrit, blood sample volume and punching location on DBS sampling was investigated. The results showed that blood sample volume or punching location has no impact on assay performance, but the presence of a high hematocrit resulted in significantly increased analyte concentrations measured from the high QC samples. The current method was fully validated over the range of 10.0-5000 ng/ml with correlation coefficients (r(2)) for three validation batches equal to or better than 0.991. The accuracy and precision (CV) at the LLOQ were -0.7 to 6.0% bias of the nominal value (10.0 ng/ml) and 10.2-2.3%, respectively. For the balance of QC samples (20.0, 50.0, 750, 1500 and 3750 ng/ml), the precision (CV) ranged from 3.2 to 11.7% and from 5.6 to 10.2%, respectively, for the intra-day and inter-day evaluations. The accuracy ranged from -6.8 to 8.5% and -0.2% to 2.7% bias, respectively, for the intra-day and inter-day batches. NIM811 is stable in the DBS samples for at least 24h at room temperature and 4h at 60°C. Interestingly, the long term stability (LTS) assessment showed that the stability of the analyte is better when the DBS samples were stored at a lower storage temperature (e.g. ≤ -60°C) compared to storage at room temperature. This is probably due to the interaction of the additives and/or other materials (e.g. cellulose, etc) on the DBS card with NIM811, a cyclic peptide. The current methodology has been applied to determine the NIM811 levels in DBS samples prepared from a clinical study.  相似文献   

5.
This study compared 25-hydroxyvitamin D [25(OH)D] measurements in capillary and venous blood samples collected, respectively by fingerprick and venipuncture. Capillary blood for measuring 25(OH)D has potential advantages by reducing blood volume required (2mL versus 0.3mL for venipuncture and capillary sampling, respectively), facilitating blood collection for those populations in whom venipuncture is difficult (e.g. infants and children), improving patient convenience and reducing costs associated with phlebotomy. The results demonstrated a highly significant relationship between 25(OH)D levels in serum derived from venous and capillary blood samples (r(2)=0.901). Despite statistically higher 25(OH)D levels in fingerprick samples (108+/-9nmol/L) compared with venipuncture samples (90+/-7nmol/L), the correlation between venous and capillary samples provides support for this approach as a practical alternative to venipuncture for vitamin D determination. However, clinical application may require the incorporation of a correction factor for the assessment of insufficiency, and research studies should avoid using the two methods interchangeably. Studying vitamin D's role in health and disease requires collection techniques and measurement methods that are reliable, reproducible, easily accessible, inexpensive and minimally burdensome to the patient. The option to collect patient samples by fingerprick may facilitate the collection process.  相似文献   

6.
Quantitative metabolite profiling in biological samples has the potential to reflect physiological status and to identify disease associated disturbances in metabolic networks. However, this approach is hampered by a wide range of preanalytical variables. Hence, the aim of our study was to develop a standardized preanalytical protocol for metabolite profiling of amino acids and acylcarnitines in human blood. Amino acids and acylcarnitines were simultaneous analyzed after butylation of 3 μL dried blood or 10 μL whole blood, serum and anticoagulated plasma using electrospray tandem-mass spectrometry. The influence of exogenous and endogenous preanalytical variables was investigated in healthy volunteers. Different sampling materials and anticoagulants for blood taking were investigated. Concentrations of long-chain acylcarnitines were 5-fold higher in EDTA-whole blood or dried whole blood compared to serum and anticoagulated plasma. Significant differences in amino acid concentrations were found for capillary versus venous blood taking. Fasting for 8 h before specimen collection minimized the nutritional influence. Physical activity significantly alters amino acid and short chain acylcarnitine concentrations. As a result of our preanalytical investigation we developed a pre-treatment protocol based on EDTA whole blood dried on filter paper to reduce the preanalytical variability and facilitate reproducible quantitative metabolite profiling in clinical trials.  相似文献   

7.
An HPLC-UV-dried blood spot (DBS) method for the estimation of metronidazole (MTZ) in rat whole blood is reported. Method employs Ahlstrom 226 sample collection paper and DBS samples were prepared by spotting with 30 μl of whole blood (spiked calibration standards/quality control samples/in vivo study samples). A 6mm disc was punched from each DBS and extraction was carried out using water containing the internal standard (tinidazole). The calibration for MTZ was linear over 2.5-50 μg/ml concentration range. Accuracy (% bias) and precision (expressed as % Coefficient of variation) values for within and between day were <20% at the lower level quality control sample (LQC) and <15% at all other concentrations tested. The limit of quantification (LOQ) of the method was 2.5 μg/ml. The validated method was applied for the analysis of in vivo pharmacokinetic (PK) study samples after intravenous administration of MTZ to a rat. Whole blood PK parameters observed in this study were in compliance with literature based PK parameters. The DBS sampling approach was found to be useful in a single animal pharmacokinetic study.  相似文献   

8.
AIM: The influence of sample handling on soluble urokinase plasminogen activator receptor (suPAR) concentrations in serum and EDTA plasma was studied in 16 healthy premenopausal women. METHOD: Blood was collected in dry tubes and tubes containing EDTA and kept at 4 degrees C or 20 degrees C for 1, 3, 8, 24 or 72 hours before processing into serum or EDTA plasma. In addition, serum and EDTA plasma were frozen and thawed 1-8 times. All suPAR measurements were performed by ELISA. RESULTS: No significant differences were found between serum or EDTA plasma suPAR concentrations when whole blood samples were kept for 1, 3, 8 or 24 hours. Significantly higher suPAR levels were found in samples kept for 72 hours at 20 degrees C compared to samples processed into serum or EDTA plasma after short-term storage for no more than 24 hours after collection. No significant differences were observed when whole blood was kept at 4 degrees C for up to 72 hours. Repeated freezing and thawing had no significant effect on the serum and EDTA plasma suPAR levels. CONCLUSION: suPAR values in blood samples are dependent on the handling procedures of the samples. All samples of whole blood must be processed into EDTA plasma or serum within 24 hours if kept at 20 degrees C and within 72 hours if kept at 4 degrees C. However, repeated freezing/thawing cycles had no influence on suPAR values in the samples.  相似文献   

9.

Background

In large-scale epidemiology, bloodspot sampling by fingerstick onto filter paper has many advantages, including ease and low costs of collection, processing and transport. We describe the development of an enzyme-linked immunoassay (ELISA) for quantifying insulin from dried blood spots and demonstrate its application in a large trial.

Methods

We adapted an existing commercial kit (Mercodia Human Insulin ELISA, 10-1113-01) to quantify insulin from two 3-mm diameter discs (≈6 µL of blood) punched from whole blood standards and from trial samples. Paediatricians collected dried blood spots in a follow-up of 13,879 fasted children aged 11.5 years (interquartile range 11.3–11.8 years) from 31 trial sites across Belarus. We quantified bloodspot insulin levels and examined their distribution by demography and anthropometry.

Results

Mean intra-assay (n = 157) coefficients of variation were 15% and 6% for ‘low’ (6.7 mU/L) and ‘high’ (23.1 mU/L) values, respectively; the respective inter-assay values (n = 33) were 23% and 11%. The intraclass correlation coefficient between 50 paired whole bloodspot versus serum samples, collected simultaneously, was 0.90 (95% confidence interval 0.85 to 0.95). Bloodspot insulin was stable for at least 31 months at −80°C, for one week at +30°C and following four freeze-thaw cycles. Paediatricians collected a median of 8 blood spots from 13,487 (97%) children. The geometric mean insulin (log standard deviation) concentrations amongst 12,812 children were 3.0 mU/L (1.1) in boys and 4.0 mU/L (1.0) in girls and were positively associated with pubertal stage, measures of central and peripheral adiposity, height and fasting glucose.

Conclusions

Our simple and convenient bloodspot assay is suitable for the measurement of insulin in very small volumes of blood collected on filter paper cards and can be applied to large-scale epidemiology studies of the early-life determinants of circulating insulin.  相似文献   

10.
We have developed a high-performance capillary electrophoresis (HPCE) method to analyze the retinol (vitamin A) concentration as retinol-retinol binding protein (holo-RBP) from microvolumes of serum (5–10 μl) or one to two drops (∼20 μl) of blood collected and air-dried on blood collection filter paper. A 0.64-cm diameter disk was cut from the dried whole blood specimens and the samples were dissolved in a pretreatment buffer and filtered. Filtrate was injected onto the HPCE column for analysis. The separation was carried out in a 60 cm × 50 μm I.D. fused-silica capillary and the running voltage was 20 kV. A HeCd laser with a wavelength of 325 nm was used for excitation, and the fluorescence of the holo-RBP complex was monitored at 465 nm by a photodiode. A virtual linear relationship was obtained for the retinol concentrations between HPCE and HPLC for 28 serum samples, 19 dried venous blood samples and 9 capillary dried blood spot samples, indicating that valid measures of serum retinol can be obtained from one to two drops of capillary blood collected on filter paper. The absolute detection limit for retinol by HPCE is below 3 μg/l. The method is very useful for vitamin A level screening, especially for children and premature new-born babies.  相似文献   

11.
The idea of collecting blood on a paper card and subsequently using the dried blood spots (DBS) for diagnostic purposes originated a century ago. Since then, DBS testing for decades has remained predominantly focused on the diagnosis of infectious diseases especially in resource-limited settings or the systematic screening of newborns for inherited metabolic disorders and only recently have a variety of new and innovative DBS applications begun to emerge. For many years, pre-analytical variables were only inappropriately considered in the field of DBS testing and even today, with the exception of newborn screening, the entire pre-analytical phase, which comprises the preparation and processing of DBS for their final analysis has not been standardized. Given this background, a comprehensive step-by-step protocol, which covers al the essential phases, is proposed, i.e., collection of blood; preparation of blood spots; drying of blood spots; storage and transportation of DBS; elution of DBS, and finally analyses of DBS eluates. The effectiveness of this protocol was first evaluated with 1,762 coupled serum/DBS pairs for detecting markers of hepatitis B virus, hepatitis C virus, and human immunodeficiency virus infections on an automated analytical platform. In a second step, the protocol was utilized during a pilot study, which was conducted on active drug users in the German cities of Berlin and Essen.  相似文献   

12.
Volkmann DH 《Theriogenology》2006,66(6-7):1583-1586
The effects of anticoagulant, storage time, storage temperature, and assay method, on laboratory measurements of blood progesterone concentrations of dogs is unclear; these factors have had a dramatic effect on blood progesterone concentrations in other species (particularly cows). In six experiments, we determined the effects of assay technique (chemiluminescence versus radioimmunoassay (RIA)), storage time, and temperature, as well as the use of heparinized plasma versus serum (coagulated blood) on measured progesterone concentrations of bitches. The studies showed that: (a) RIA measured significantly higher serum progesterone concentration (SPC) than chemiluminescence; (b) refrigeration of whole blood during the first 2 h after sample collection significantly decreased measured SPC; (c) progesterone concentration in heparinized plasma was not affected by storage temperature of whole blood for at least 5 h; (d) refrigeration of whole, clotted blood did not affect SPC, provided that samples were held at room temperature for the first 2 h after collection. These findings are of particular importance when blood samples are collected for determination of the initial rise in SPC that is associated with the LH surge in estrous bitches.  相似文献   

13.
A method is described for the determination of dopexamine hydrochloride at concentrations of 5 to 1000 ng/ml in human blood using electrochemical detection. The method uses a Hypersil ODS column and a mobile phase containing heptane sulphonate, orthophosphoric acid, diisopropylamine and disodium EDTA. Blood samples are stabilised immediately after collection by the use of dipotassium EDTA and a high concentration of sodium metabisulphite. The sample preparation procedure consists of a simple de-proteinisation with perchloric acid. The method is accurate, with inter-assay accuracies ranging from 100 to 104%, and is free of interference by blood from different individuals. Known and potential metabolites of dopexamine hydrochloride and a wide range of drugs do not interfere with the method. The method is precise with inter-assay coefficients on variation of 10.6% at 5 ng/ml and of less than 4.2% at higher concentrations. Stabilised blood samples may be stored for over six months at −25°C prior to analysis.  相似文献   

14.

Background  

Testing for viral DNA in neonatal blood dried on paper (DBS) has proved a valid means of diagnosing congenital CMV infection with both clinical and epidemiological relevance. To assess the quality of the detection of CMV-DNA on DBS in laboratories performing this test a proficiency panel consisting of nine samples with two blood spots on each filter paper was produced and distributed. Six samples were derived from whole blood, negative for CMV DNA and antibody, and spiked with cell-grown CMV Towne in various concentrations (7.3 × 102 - 9.6 × 105 copies/ml), one was a CMV positive clinical specimen (3.9 × 106 copies/ml), and two samples were CMV-negative whole blood.  相似文献   

15.
Serological analysis is an integral part of laboratory practice nowadays. The present study was aimed to develop and validate a modified Enzyme linked Immunosorbent Assay (ELISA) for determination of IgG antibody against Hepatitis E Virus (HEV) using dried blood spots (DBS) and corresponding plasma samples. A total of 65 samples (45 HEV patients, 20 healthy controls) were analyzed. DBS and plasma samples demonstrated equivalent optical densities for detecting anti-HEV IgG. A highly significant correlation was observed between plasma and DBS sample absorbances (R2 = 0.98; p < 0.001) at dilution 1:200, indicating true agreement between the two procedures. The assay exhibited decent linearity and showed no effect of physiological hematocrit on assay performance. Data suggested recommendable promise in using DBS as a suitable alternative to plasma samples to determine HEV IgG antibody evidenced by significant correlation with plasma results. Therefore, identical method for processing DBS specimens including it's proper storage is recommended for implementation of a modified ELISA in different settings.  相似文献   

16.
The collection, processing and transportation to a testing laboratory of large numbers of clinical samples during an emergency response situation present significant cost and logistical issues. Blood and serum are common clinical samples for diagnosis of disease. Serum preparation requires significant on-site equipment and facilities for immediate processing and cold storage, and significant costs for cold-chain transport to testing facilities. The dried blood spot (DBS) matrix offers an alternative to serum for rapid and efficient sample collection with fewer on-site equipment requirements and considerably lower storage and transport costs. We have developed and validated assay methods for using DBS in the quantitative anti-protective antigen IgG enzyme-linked immunosorbent assay (ELISA), one of the primary assays for assessing immunogenicity of anthrax vaccine and for confirmatory diagnosis of Bacillus anthracis infection in humans. We have also developed and validated high-throughput data analysis software to facilitate data handling for large clinical trials and emergency response.  相似文献   

17.
Measurement of blood viscosity using mass-detecting sensor   总被引:1,自引:0,他引:1  
A newly designed mass-detecting capillary viscometer is extended to measure the viscosity of whole blood over a range of shear rates without the use of anticoagulants in a clinical setting. In the present study as proof of principle, a single measurement of liquid-mass variation with time replaces the flow rate and pressure drop measurements that are usually required for the operation of a capillary tube viscometer. Using a load cell and capillary, we measured the change of mass flowing through capillary tube with respect to the time, m(t), from which viscosity and shear rate were mathematically calculated. For water and adulterated bloods, excellent agreement was found between the results from the mass-detecting capillary viscometer and those from a commercially available rotating viscometer. Also, the mass-detecting capillary viscometer measured the viscosity of unadulterated whole blood without heparin or EDTA. This new method overcomes the drawbacks of conventional viscometers in the measurement of the whole blood viscosity. First, the mass-detecting capillary viscometer can accurately and consistently measure the unadulterated blood viscosity over a range of shear rates in less than 2 min without any anticoagulants. Second, this design provides simplicity (i.e. ease of operation, no moving parts, and disposable) and low cost.  相似文献   

18.
Plasma lipid analysis, particularly in population screening, can be facilitated by the use of capillary blood. A system for serial collection of capillary plasma is described. The concentrations of total cholesterol, HDL-cholesterol and triglycerides in heparinized capillary plasma and venous blood, respectively, are compared. No significant differences were found. Using the KAPA-method hemolytic samples are a source of error. They occurred with a frequency of about 3% in mass screening.  相似文献   

19.
We have recently described a new capillary electrophoresis assay to measure serum ascorbic and uric acids in which a baseline separation of peaks was obtained in less than 4 min by using a 60.2 cm x 75 microm uncoated capillary with a 100 mmol/L sodium borate running buffer pH 8. Since during sample preparation AA is rapidly oxidized, we employed our new capillary electrophoresis method to analyze the pre-analytical factors affecting its stability. In particular we evaluated how the standard mix preparation, the blood collection (plasma EDTA or serum) and the plasma protein precipitation influence the results of analysis. Our data suggest that standard ascorbate must be dissolved in a solution containing cysteine and EDTA in order to avoid oxidation and that EDTA blood collection is better than serum for AA measurement. Moreover, the type and the quantity of the precipitating compound are critical parameters to obtain a complete recovery of analytes. We performed AA and UA analysis in 32 healthy volunteers with the optimized experimental conditions by using our capillary electrophoresis method and a reference CE assay. Obtained data were compared to Bland-Altman test to verify the accuracy of our CZE method.  相似文献   

20.
Moxifloxacin (MFX) is a potential oral agent use in the treatment of multidrug-resistance tuberculosis (MDR-TB). Due to variability in pharmacokinetics and in vitro susceptibility of causative bacteria, therapeutic drug monitoring (TDM) of MFX is recommended. Conventional plasma sampling for TDM is facing logistical challenges, especially in limited resource areas, and dried blood spots (DBS) sampling may offer a chance to overcome this problem. The objective of this study was to develop a LC-MS/MS method for determination of MFX in dried blood spots (DBS) that is applicable for TDM. The influence of paper type, the hematocrit (Hct) and the blood volume per spot (V(b)) on the estimated blood volume in a disc (V(est)) was investigated. The extracts of 8mm diameter discs punched out from DBS were analyzed using liquid chromatography tandem mass spectrometry (LC-MS/MS) with cyanoimipramin as internal standard. The method was validated with respect to selectivity, linearity, accuracy, precision, sensitivity, recovery and stability. The effect of Hct and V(b) on LC-MS/MS analytical result was also investigated. The relationship between MFX concentrations in venous and finger prick DBS and those in plasma was clinically explored. V(est) was highly influenced by Hct while the effect of V(b) appeared to be different among paper types. Calibration curves were linear in the range of 0.05-6.00 mg/L with inter-day and intra-day precisions and biases of less than 11.1%. The recovery was 84.5, 85.1 and 92.6% in response to blood concentration of 0.15, 2.50 and 5.00 mg/L, respectively. A matrix effect of less than 11.9% was observed. MFX in DBS was stable for at least 4 weeks at room condition (temperature of 25°C and humidity of 50%). A large range of Hct value produced a significant analytical bias and it can be corrected with resulting DBS size. A good correlation between DBS and plasma concentrations was observed and comparable results between venous DBS and finger prick DBS was attained. This fully validated method is suitable for determination of MFX in dried blood spot and applicable for TDM.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号