1.
We present the theory and application of reciprocal space image correlation spectroscopy (kICS). This technique measures the number density, diffusion coefficient, and velocity of fluorescently labeled macromolecules in a cell membrane imaged on a confocal, two-photon, or total internal reflection fluorescence microscope. In contrast to r-space correlation techniques, we show kICS can recover accurate dynamics even in the presence of complex fluorophore photobleaching and/or "blinking". Furthermore, these quantities can be calculated without nonlinear curve fitting, or any knowledge of the beam radius of the exciting laser. The number densities calculated by kICS are less sensitive to spatial inhomogeneity of the fluorophore distribution than densities measured using image correlation spectroscopy. We use simulations as a proof-of-principle to show that number densities and transport coefficients can be extracted using this technique. We present calibration measurements with fluorescent microspheres imaged on a confocal microscope, which recover Stokes-Einstein diffusion coefficients, and flow velocities that agree with single particle tracking measurements. We also show the application of kICS to measurements of the transport dynamics of alpha5-integrin/enhanced green fluorescent protein constructs in a transfected CHO cell imaged on a total internal reflection fluorescence microscope using charge-coupled device area detection.  相似文献   

2.
Methods applicable to visualizing single fluorophores in living cells are described, namely, laser epifluorescence, confocal, near-field, two-photon, and total internal reflection microscopy. It is demonstrated that total internal reflection microscopy is the most appropriate for visualizing single fluorophores near the substrate-medium interface. This method can be used for studying receptors, ion channels, and numerous cytoskeletal and signal molecules located on or near the basal cell membrane. It is demonstrated that stringent criteria are necessary when identifying single molecules, as these objects emit a limited number of photons before irreversible photobleaching and their fluorescence is obscured by autofluorescence or out-of-focus fluorescence. The methods used for studying the lateral mobility of single molecules floating on the cell membrane are also described.  相似文献   

3.
The methods have been described that can be used to visualize single fluorescent molecules in live cells: laser epifluorescent, confocal, near-field, two-photon, and total internal reflection microscopy. Each method has its own advantages and limitations. We showed that total internal reflection microscopy is a method of choice for single fluorophore visualisation near substrate-medium interface. It can be used to study receptors, ion channels, and many cytoskeleton or signalling molecules located at or in close proximity to basal cell membrane. It was shown that it is very important to use rigorous criteria for single fluorophore identification since these objects emit a limited number of photons before irreversible photo-bleaching, and their fluorescence is often obscured by cell auto-fluorescence and out-of-focus fluorescence. Methods used for lateral mobility studies of single molecules floating on cell membrane were also described.  相似文献   

4.
The ability to measure properties of a single cross-bridge in working muscle is important because it avoids averaging the signal from a large number of molecules and because it probes cross-bridges in their native crowded environment. Because the concentration of myosin in muscle is large, observing the kinetics of a single myosin molecule requires that the signal be collected from small volumes. The introduction of small observational volumes defined by diffraction-limited laser beams and confocal detection has made it possible to limit the observational volume to a femtoliter (10(-15) liter). By restraining labeling to 1 fluorophore per 100 myosin molecules, we were able to follow the kinetics of approximately 400 cross-bridges. To reduce this number further, we used two-photon (2P) microscopy. The focal plane in which the laser power density was high enough to produce 2P absorption was thinner than in confocal microscopy. Using 2P microscopy, we were able to observe approximately 200 cross-bridges during contraction. The novel method of confocal total internal reflection (CTIR) provides a method to reduce the observational volume even further, to approximately 1 attoliter (10(-18) liter), and to measure fluorescence with a high signal-to-noise (S/N) ratio. In this method, the observational volume is made shallow by illuminating the sample with an evanescent field produced by total internal reflection (TIR) of the incident laser beam. To guarantee the small lateral dimensions of the observational volume, a confocal aperture is inserted in the conjugate-image plane of the objective. With a 3.5-mum confocal aperture, we achieved a volume of 1.5 attoliter. Association-dissociation of the myosin head was probed with rhodamine attached at cys707 of the heavy chain of myosin. Signal was contributed by one to five fluorescent myosin molecules. Fluorescence decayed in a series of discrete steps, corresponding to bleaching of individual molecules of rhodamine. The S/N ratio was sufficiently large to make statistically significant comparisons from rigor and contracting myofibrils.  相似文献   

5.
Tethered particle microscopy is a powerful tool to study the dynamics of DNA molecules and DNA-protein complexes in single-molecule experiments. We demonstrate that stroboscopic total internal reflection microscopy can be used to characterize the three-dimensional spatiotemporal motion of DNA-tethered particles. By calculating characteristic measures such as symmetry and time constants of the motion, well-formed tethers can be distinguished from defective ones for which the motion is dominated by aberrant surface effects. This improves the reliability of measurements on tether dynamics. For instance, in observations of protein-mediated DNA looping, loop formation is distinguished from adsorption and other nonspecific events.  相似文献   

6.
Quantification of molecular numbers and concentrations in living cells is critical for testing models of complex biological phenomena. Counting molecules in cells requires estimation of the fluorescence intensity of single molecules, which is generally limited to imaging near cell surfaces, in isolated cells, or where motions are diffusive. To circumvent this difficulty, we have devised a calibration technique for spinning–disk confocal microscopy, commonly used for imaging in tissues, that uses single–step bleaching kinetics to estimate the single–fluorophore intensity. To cross–check our calibrations, we compared the brightness of fluorophores in the SDC microscope to those in the total internal reflection and epifluorescence microscopes. We applied this calibration method to quantify the number of end–binding protein 1 (EB1)–eGFP in the comets of growing microtubule ends and to measure the cytoplasmic concentration of EB1–eGFP in sensory neurons in fly larvae. These measurements allowed us to estimate the dissociation constant of EB1–eGFP from the microtubules as well as the GTP–tubulin cap size. Our results show the unexplored potential of single–molecule imaging using spinning–disk confocal microscopy and provide a straightforward method to count the absolute number of fluorophores in tissues that can be applied to a wide range of biological systems and imaging techniques.  相似文献   

7.
Combining scanning probe and optical microscopy represents a powerful approach for investigating structure-function relationships and dynamics of biomolecules and biomolecular assemblies, often in situ and in real-time. This platform technology allows us to obtain three-dimensional images of individual molecules with nanometer resolution, while simultaneously characterizing their structure and interactions though complementary techniques such as optical microscopy and spectroscopy. We describe herein the practical strategies for the coupling of scanning probe and total internal reflection fluorescence microscopy along with challenges and the potential applications of such platforms, with a particular focus on their application to the study of biomolecular interactions at membrane surfaces.  相似文献   

8.
The dynamics of clathrin-mediated endocytosis can be assayed using fluorescently tagged proteins and total internal reflection fluorescence microscopy. Many of these proteins, including clathrin and dynamin, are soluble and changes in fluorescence intensity can be attributed either to membrane/vesicle movement or to changes in the numbers of individual molecules. It is important for assays to discriminate between physical membrane events and the dynamics of molecules. Two physical events in endocytosis were investigated: vesicle scission from the plasma membrane and vesicle internalization. Single vesicle analysis allowed the characterization of dynamin and clathrin dynamics relative to scission and internalization. We show that vesicles remain proximal to the plasma membrane for variable amounts of time following scission, and that uncoating of clathrin can occur before or after vesicle internalization. The dynamics of dynamin also vary with respect to scission. Results from assays based on physical events suggest that disappearance of fluorescence from the evanescent field should be re-evaluated as an assay for endocytosis. These results illustrate the heterogeneity of behaviors of endocytic vesicles and the importance of establishing suitable evaluation criteria for biophysical processes.  相似文献   

9.
To start systematically investigating the quality improvement of protein crystals, the elementary growth processes of protein crystals must be first clarified comprehensively. Atomic force microscopy (AFM) has made a tremendous contribution toward elucidating the elementary growth processes of protein crystals and has confirmed that protein crystals grow layer by layer utilizing kinks on steps, as in the case of inorganic and low-molecular-weight compound crystals. However, the scanning of the AFM cantilever greatly disturbs the concentration distribution and solution flow in the vicinity of growing protein crystals. AFM also cannot visualize the dynamic behavior of mobile solute and impurity molecules on protein crystal surfaces. To compensate for these disadvantages of AFM, in situ observation by two types of advanced optical microscopy has been recently performed. To observe the elementary steps of protein crystals noninvasively, laser confocal microscopy combined with differential interference contrast microscopy (LCM-DIM) was developed. To visualize individual mobile protein molecules, total internal reflection fluorescent (TIRF) microscopy, which is widely used in the field of biological physics, was applied to the visualization of protein crystal surfaces. In this review, recent progress in the noninvasive in situ observation of elementary steps and individual mobile protein molecules on protein crystal surfaces is outlined.  相似文献   

10.
Live-cell microscopy imaging of fluorescent-tagged fusion proteins is an essential tool for cell biologists. Total internal reflection fluorescence microscopy (TIRFM) has joined confocal microscopy as a complementary system for the imaging of cell surface protein dynamics in mammalian and yeast systems because of its high temporal and spatial resolution. Here we present an alternative to TIRFM, termed variable-angle epifluorescence microscopy (VAEM), for the visualization of protein dynamics at or near the plasma membrane of plant epidermal cells and root hairs in whole, intact seedlings that provides high-signal, low-background and near real-time imaging. VAEM uses highly oblique subcritical incident angles to decrease background fluorophore excitation. We discuss the utilities and advantages of VAEM for imaging of fluorescent fusion-tagged marker proteins in studying cortical cytoskeletal and membrane proteins. We believe that the application of VAEM will be an invaluable imaging tool for plant cell biologists.  相似文献   

11.
Molecular machines within cells dynamically assemble, disassemble and reorganize. Molecular interactions between their components can be observed at the single-molecule level and quantified using colocalization single-molecule spectroscopy, in which individual labeled molecules are seen transiently associating with a surface-tethered partner, or other total internal reflection fluorescence microscopy approaches in which the interactions elicit changes in fluorescence in the labeled surface-tethered partner. When multiple interacting partners can form ternary, quaternary and higher order complexes, the types of spatial and temporal organization of these complexes can be deduced from the order of appearance and reorganization of the components. Time evolution of complex architectures can be followed by changes in the fluorescence behavior in multiple channels. Here, we describe the kinetic event resolving algorithm (KERA), a software tool for organizing and sorting the discretized fluorescent trajectories from a range of single-molecule experiments. KERA organizes the data in groups by transition patterns, and displays exhaustive dwell time data for each interaction sequence. Enumerating and quantifying sequences of molecular interactions provides important information regarding the underlying mechanism of the assembly, dynamics and architecture of the macromolecular complexes. We demonstrate KERA’s utility by analyzing conformational dynamics of two DNA binding proteins: replication protein A and xeroderma pigmentosum complementation group D helicase.  相似文献   

12.
A novel, multifunctional optical imaging system was developed by integrating four-dimensional (4D) real-time confocal microscopy (RT-CM), multicolor total internal reflection microscopy (TIRFM), and Nomarski differential interference contrast (DIC) microscopy based on an epifluorescence microscope platform. A microcell incubator was combined with the imaging system for extended, real-time monitoring of living cells. The 4D images were generated by a combination of 3D images and multiple spatial or time images of a specimen, obtained at 10 nm intervals. Optical sectioning was accomplished with a z-motor, which obtained 4D information with sequential layered sections. The integrated imaging system showed excellent detection sensitivity at the single-molecule level and 3D-spatial resolution (20 nm x-y and 10 nm z-axis) without moving the cell sample. This could be a tool for obtaining crucial information needed to develop approaches for characterizing and understanding the dynamics of biomolecules and nanoparticles in individual living cells and molecular interactions at the single-molecule level.  相似文献   

13.
We have developed a new method based on total internal reflection fluorescence to map the shape of the region between glass and the lower surface of a living cell spread upon it. Fluorescently labeled nonadsorbing volume marker molecules that cannot penetrate into the cell are locally stimulated so that they fluoresce only very near the glass/medium interface. The total fluorescence intensity at any point beneath the cell depends on the cell-to-glass separation. Focal contacts appear as dark areas owing to dye exclusion, whereas when the gap exceeds approximately 150 nm, fluorescence asymptotes to the bright background level. Our technique provides greater contrast than does interference reflection microscopy and is free from errors due to cytoplasmic thickness and refractive index inhomogeneities arising from cytoplasmic inclusions. We have shown that sufficiently large molecules suffer steric exclusion from regions accessible to small molecules, which gives new information about lateral penetrability in the apposition region.  相似文献   

14.
Burghardt TP  Ajtai K  Borejdo J 《Biochemistry》2006,45(13):4058-4068
Confocal microscopy is widely used for acquiring high spatial resolution tissue sample images of interesting fluorescent molecules inside cells. The fluorescent molecules are often tagged proteins participating in a biological function. The high spatial resolution of confocal microscopy compared to wide field imaging comes from an ability to optically isolate and image exceedingly small volume elements made up of the lateral (focal plane) and depth dimensions. Confocal microscopy at the optical diffraction limit images volumes on the order of approximately 0.5 femtoliter (10(-15) L). Further resolution enhancement can be achieved with total internal reflection microscopy (TIRM). With TIRM, an exponentially decaying electromagnetic field (near-field) established on the surface of the sample defines a subdiffraction limit dimension that, when combined with conventional confocal microscopy, permits image formation from <7 attoL (10(-18) L) volumes [Borejdo et al. (2006) Biochim. Biophys. Acta, in press]. Demonstrated here is a new variation of TIRM, focused TIRM (fTIRM) that decreases the volume element to approximately 3 attoL. These estimates were verified experimentally by measuring characteristic times for Brownian motion of fluorescent nanospheres through the volume elements. A novel application for TIRM is in situ single-molecule fluorescence spectroscopy. Single-molecule studies of protein structure and function are well-known to avoid the ambiguities introduced by ensemble averaging. In situ, proteins are subjected to the native forces of the crowded environment in the cell that are not present in vitro. The attoL fluorescence detection volume of TIRM permits isolation of single proteins in situ. Muscle tissue contains myosin at a approximately 120 microM concentration. Evidence is provided that >75% of the bleachable fluorescence detected with fTIRM is emitted by five chromophore-labeled myosins in a muscle fiber.  相似文献   

15.
Beer C  Pedersen L 《Journal of virology》2007,81(15):8247-8257
A major entry route for the gammaretrovirus amphotropic murine leukemia virus (A-MLV) into NIH 3T3 fibroblasts is via caveola-dependent endocytosis. However, during the infection time, few viral particles can be observed intracellularly. Analyzing the dynamics of the A-MLV infection process by using total internal reflection fluorescence microscopy, we show that the majority of viruses are extracellular and bound to the fibronectin matrix. Moreover, the amounts of bound virus and of fibronectin correlated. Using confocal microscopy, nanoparticles targeted to fibronectin by a III1C-fibronectin fragment or anti-fibronectin antibody were detected intracellularly in NIH 3T3 cells; unconjugated nanoparticles neither bound to cells nor were detectable intracellularly. Furthermore, A-MLV colocalized intracellularly with the fibronectin-targeted nanoparticles, suggesting that they were taken up by the same cellular pathway. Both A-MLV entry and fibronectin turnover depend on caveolar endocytosis, and we found that inhibiting viral binding to the extracellular NIH 3T3 fibronectin-matrix dramatically reduced A-MLV infection, indeed, showing an active role of fibronectin in infection. We suggest that binding to the cellular fibronectin matrix provides a new mechanism by which viruses can enter cells.  相似文献   

16.
17.
Micropatterning approaches using self-assembled monolayers of alkyl thiols on gold are not optimal for important imaging modalities in cell biology because of absorption of light and scattering of electrons by the gold layer. We report here an anisotropic solid microetching (ASOMIC) procedure that overcomes these limitations. The method allows molecular dynamics imaging by wide-field and total internal reflection fluorescence (TIRF) microscopy of living mammalian cells and correlative platinum replica electron microscopy.  相似文献   

18.
19.
We test here a previously proposed hypothesis about lateral heterogeneity of cell membranes, a model predicting that heterogeneity is maintained by a combination of delivery and intake of molecules with barriers to lateral free diffusion. To test the validity of the model, we observed green fluorescent protein tagged major histocompatibility complex class I patches on the plasma membrane of mouse fibroblasts, using total internal reflection fluorescence microscopy in real time. The dynamic characterization revealed the life course of these patches comprises delivery of molecules at a short instant, followed by a slow, exponential decay, corresponding to diffusion of the molecules over dynamic barriers to free lateral diffusion. The characteristic lifetime of the patches, extracted from the measurements, is approximately 30 s, in excellent agreement with the predictions of the model.  相似文献   

20.
DNA helicases are motor proteins that catalyze the unwinding of double-stranded DNA into single-stranded DNA using the free energy from ATP hydrolysis. Single molecule approaches enable us to address detailed mechanistic questions about how such enzymes move processively along DNA. Here, an optical method has been developed to follow the unwinding of multiple DNA molecules simultaneously in real time. This was achieved by measuring the accumulation of fluorescent single-stranded DNA-binding protein on the single-stranded DNA product of the helicase, using total internal reflection fluorescence microscopy. By immobilizing either the DNA or helicase, localized increase in fluorescence provides information about the rate of unwinding and the processivity of individual enzymes. In addition, it reveals details of the unwinding process, such as pauses and bursts of activity. The generic and versatile nature of the assay makes it applicable to a variety of DNA helicases and DNA templates. The method is an important addition to the single-molecule toolbox available for studying DNA processing enzymes.  相似文献   