首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 683 毫秒
1.
Qu F  Yang M  Jiang J  Shen G  Yu R 《Analytical biochemistry》2005,344(1):108-114
Conducting polymer film was prepared by electrochemical polymerization of aniline. Multiwalled carbon nanotubes (MWNTs) were treated with a mixture of concentrated sulfuric and nitric acid to introduce carboxylic acid groups to the nanotubes. By using the layer-by-layer method, homogeneous and stable MWNTs and polyaniline (PANI) multilayer films were alternately assembled on glassy carbon (GC) electrodes. Conducting polymer of PANI had three main functions: (i) excellent antiinterference ability, (ii) protection ability in favor of increasing the amount of the MWNTs immobilized on GC electrodes, and (iii) superior transducing ability. The protection effect of PANI film and the electrostatic interaction between positively charged PANI and negatively charged MWNTs both attributed to immobilizing abundant MWNTs stably, thereby enhancing the catalytic activity. The layer-by-layer assembled MWNTs and PANI-modified GC electrodes offered a significant decrease in the overvoltage for the H2O2 and were shown to be excellent amperometric sensors for H2O2 from +0.2V over a wide range of concentrations. As an application example, by linking choline oxidase (CHOD), an amplified biosensor toward choline was prepared. The choline biosensor exhibited a linear response range of 1x10(-6) to 2x10(-3) M with a correlation coefficient of 0.997, and the response time and detection limit (S/N=3) were determined to be 3 s and 0.3 microM, respectively. The antiinterference biosensor displays a rapid response and an expanded linear response range as well as excellent reproducibility and stability.  相似文献   

2.
A convenient and effective strategy for preparation nanohybrid film of multi-wall carbon nanotubes (MWNT) and gold colloidal nanoparticles (GNPs) by using proteins as linker is proposed. In such a strategy, hemoglobin (Hb) was selected as model protein to fabricate third-generation H2O2 biosensor based on MWNT and GNPs. Acid-pretreated, negatively charged MWNT was first modified on the surface of glassy carbon (GC) electrode, then, positively charged Hb was adsorbed onto MWNT films by electrostatic interaction. The {Hb/GNPs}n multilayer films were finally assembled onto Hb/MWNT film through layer-by-layer assembly technique. The assembly of Hb and GNPs was characterized with cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS) and transmission electron microscopy (TEM). The direct electron transfer of Hb is observed on Hb/GNPs/Hb/MWNT/GC electrode, which exhibits excellent electrocatalytic activity for the reduction of H2O2 to construct a third-generation mediator-free H2O2 biosensor. As compared to those H2O2 biosensors only based on carbon nanotubes, the proposed biosensor modified with MWNT and GNPs displays a broader linear range and a lower detection limit for H2O2 determination. The linear range is from 2.1x10(-7) to 3.0x10(-3) M with a detection limit of 8.0x10(-8) M at 3sigma. The Michaelies-Menten constant KMapp value is estimated to be 0.26 mM. Moreover, this biosensor displays rapid response to H2O2 and possesses good stability and reproducibility.  相似文献   

3.
This study demonstrates a polyelectrolyte-free method to fabricate controllable and stable all-MWNTs films via a covalent layer-by-layer (LBL) deposition. Aminated MWNTs and carboxylated MWNTs were prepared by surface functionalization, allowing the incorporation of MWNTs into highly tunable thin films through the formation of covalent amide bonds. Fourier transform infrared spectroscopy (FTIR) analysis demonstrated the formation of covalent linkages between MWNTs layers. Scanning electron microscopy (SEM) and ultraviolet-visible spectroscopy (UV-vis) were used to characterize the assembly process. Electrochemical studies indicated that the all-MWNTs film possessed a remarkable electrocatalytic activity toward dihydronicotinamide adenine dinucleotide (NADH) at relatively low potentials, without the need for redox mediators. The film thickness and the amount of assembled MWNTs were readily adjusted by simply changing the number of cycles in the LBL assembly process, which also effectively tuned the electrocatalytic activity of the film toward NADH. The film constructed with four bilayers showed a high sensitivity of 223.8μAmM(-1)cm(-2) and a detection limit of 1.5μM, with a fast response of less than 3s. Furthermore, the all-MWNTs film also showed good selectivity and excellent stability for the determination of NADH.  相似文献   

4.
Overoxidized polypyrrole/multi-walled carbon nanotubes (OPPy/MWNTs) modified electrode has been developed for sensitively detecting dopamine (DA). OPPy films developed outside MWNTs might have a porous morphology. Thus, OPPy/MWNTs films developed by this method do not reject ascorbic acid (AA). However, OPPy/MWNTs modified electrode shows largely enhancing oxidative current responses of DA. When combined with liquid chromatography, it not only obtains a low detection limit of 7.5 × 10?10 mol L?1 for DA, but also improves the selectivity of DA detection. Mechanisms for the enhancement are also well discussed in this paper. With this approach, microdialysis has been employed for successful assessment of DA in rat striatum.  相似文献   

5.
Heat conduction in multi-walled carbon nanotubes (MWNTs) was studied using non-equilibrium molecular dynamics simulations. This research focuses on the effects of the multi-wall structure of the MWNTs on the heat conduction. The results show that the thermal conductivity of a MWNT is almost the same as that of the corresponding single-walled carbon nanotubes (SWNTs) rather than much smaller as has been suggested. Thus, the multi-wall structure does not significantly affect the thermal conduction in the MWNTs. Analysis of the temperature profiles and the phonon density of states confirms that there is almost no heat transport between the MWNT layers and that each layer conducts heat nearly independently along parallel channels. This is physically reasonable since the weak inter-wall interactions and large interfacial thermal resistances make the MWNT layers behave like parallel thermal circuits.  相似文献   

6.
Hollow nitrogen-doped carbon microspheres (HNCMS) as a novel carbon material have been prepared and the catalytic activities of HNCMS-modified glassy carbon (GC) electrode towards the electro-oxidation of uric acid (UA), ascorbic acid (AA) and dopamine (DA) have also been investigated. Comparing with the bare GC and carbon nanotubes (CNTs) modified GC (CNTs/GC) electrodes, the HNCMS modified GC (HNCMS/GC) electrode has higher catalytic activities towards the oxidation of UA, AA and DA. Moreover, the peak separations between AA and DA, and DA and UA at the HNCMS/GC electrode are up to 212 and 136 mV, respectively, which are superior to those at the CNTs/GC electrode (168 and 114 mV). Thus the simultaneous determination of UA, AA and DA was carried out successfully. In the co-existence system of UA, AA and DA, the linear response range for UA, AA and DA are 5-30 μM, 100-1000 μM and 3-75 μM, respectively and the detection limits (S/N = 3) are 0.04 μM, 0.91 μM and 0.02 μM, respectively. Meanwhile, the HNCMS/GC electrode can be applied to measure uric acid in human urine, and may be useful for measuring abnormally high concentration of AA or DA. The attractive features of HNCMS provide potential applications in the simultaneous determination of UA, AA and DA.  相似文献   

7.
A poly(3-methylthiophene) modified glassy carbon electrode coated with Nafion/single-walled carbon nanotubes film was fabricated and used for highly selective and sensitive determination of dopamine. The hybrid film surface of the modified electrode was characterized by scanning electrochemical microscopy (SECM) and the results indicated that the carbon nanotubes were dispersed uniformly on the conductive polymer. The experimental results suggest that the hybrid film modified electrode combining the advantages of poly(3-methylthiophene), carbon nanotubes with Nafion exhibits dramatic electrocatalytic effect on the oxidation of dopamine (DA) and results in a marked enhancement of the current response. In 0.1M phosphate buffer solution (PBS) of pH 7.0, the differential pulse voltammetric (DPV) peak heights are linear with DA concentration in three intervals, viz. 0.020-0.10 microM, 0.10-1.0 microM and 1.0-6.0 microM, with correlation coefficients of 0.9993, 0.9996 and 0.9993, respectively. The detection limit of 5.0 nM DA could be estimated (S/N=3). Moreover, the interferences of ascorbic acid (AA) and uric acid (UC) are effectively diminished. This hybrid film modified electrode can be applied to the determination of DA contents in dopamine hydrochloride injection and human serum. These attractive features provide a potential application for either in vitro measurement of DA in the presence of excess AA and UA or as detectors in flow injection analysis (FIA) and high performance liquid chromatography (HPLC).  相似文献   

8.
Layer-by-layer assembly of glucose oxidase (GOx) with single-wall carbon nanotubes (SWCNTs) is achieved on the electrode surface based on the electrostatic attraction between positively charged GOx in pH 3.8 buffer and negatively charged carboxylic groups of CNTs. The cyclic voltammetry and electrochemical impedance spectroscopy are used to characterize the formation of multilayer films. In deaerated buffer solutions, the cyclic voltammetry of the multilayer films of {GOx/CNT}n shows two pairs of well-behaved redox peaks that are assigned to the redox reactions of CNTs and GOx, respectively, confirming the effective immobilization of GOx on CNTs using the layer-by-layer technique. The redox peak currents of GOx increase linearly with the increased number of layers indicating the uniform growth of GOx in multilayer films. The dependence of the cyclic voltammetric response of GOx in multilayer films on the scan rate and pH is also studied. A linear decrease of the reduction current of oxygen at the {GOx/CNT}-modified electrodes with the addition of glucose suggests that such multilayer films of GOx retain the bioactivity and can be used as reagentless glucose biosensors.  相似文献   

9.
Tellurium-nanowire-coated glassy carbon electrodes (TNGCEs) have been fabricated and employed for selective and sensitive detection of dopamine (DA). TNGCEs were prepared by direct deposition of tellurium nanowires, 600 ± 150 nm in length and 16 ± 3 nm in diameter, onto glassy carbon electrodes, which were further coated with Nafion to improve their selectivity and stability. Compared to the GCE, the TNGCE is more electroactive (by approximately 1.9-fold) for DA, and its selectivity toward DA over ascorbic acid (AA) and uric acid (UA) is also greater. By applying differential pulse voltammetry, at a signal-to-noise ratio of 3, the TNGCE provides a limit of detection of 1 nM for DA in the presence of 0.5mM AA and UA. Linearity (R(2)=0.9955) of the oxidation current at 0.19 V against the concentration of DA is found over the range 5 nM-1 μM. TNGCEs have been applied to determine the concentration of dopamine to be 0.59 ± 0.07 μM in PC12 cells.  相似文献   

10.
Multi-wall carbon nanotubes (MWNTs) functionalized with amino groups were prepared via silane treatment using 3-aminopropyltrimethoxysilane (APS) as a silane-coupling agent. The resultant amino terminated MWNTs (AMWNTs) were applied to construct glucose biosensors with IO(4)(-)-oxidized glucose oxidase (IO(4)(-)-oxidized GOx) through the layer-by-layer (LBL) covalent self-assembly method without any cross-linker. Scanning electron microscopy (SEM) indicated that the assembled AMWNTs were almost in a form of small bundles or single nanotubes, and the surface density increased uniformly with the number of GOx/AMWNTs bilayers. From the analysis of voltammetric signals, a linear increment of the coverage of GOx per bilayer was estimated. The resulting biosensor showed excellent catalytic activity towards the electroreduction of dissolved oxygen at low overvoltage, based on which glucose concentration was monitored conveniently. The enzyme electrode exhibited good electrocatalytic response towards the glucose and that response increased with the number of GOx/AMWNTs bilayers, suggesting that the analytical performance such as sensitivity and detection limit of the glucose biosensors could be tuned to the desired level by adjusting the number of deposited GOx/AMWNTs bilayers. The biosensor constructed with four bilayers of GOx/AMWNTs showed high sensitivity of 7.46muAmM(-1)cm(-2) and the detection limit of 8.0muM, with a fast response less than 10s. Because of relative low applied potential, the interference from other electro-oxidizable compounds was minimized, which improved the selectivity of the biosensors. Furthermore, the obtained enzyme electrodes also showed remarkable stability due to the covalent interaction between the GOx and AMWNTs.  相似文献   

11.
The immobilization of lipases within sol–gel derived silica, using multi-walled carbon nanotubes (MWNTs) as additives in order to protect the inactivation of lipase during sol–gel process and to enhance the stability of lipase, was investigated. Three sol–gel immobilized lipases (Candida rugosa, Candida antarctica type B, Thermomyces lanuginosus) with 0.33% (w/w) MWNT showed much higher activities than lipase immobilized without MWNT. The influence of MWNT content and MWNT shortened by acid treatment in the sol–gel process on the activity and stability of immobilized C. rugosa lipase was also studied. In hydrolysis reaction, immobilized lipase containing 1.1% pristine MWNT showed 7 times higher activity than lipase immobilized without MWNT. The lipase coimmobilized with 2.7% shortened MWNT showed 10 times higher activity in esterification reaction, compared with lipase immobilized without MWNT. The lipase coimmobilized with 2.7% shortened MWNT retained 96% of initial activity after 5 times reuse, while the lipase immobilized without MWNT was fully inactivated under the same condition.  相似文献   

12.
Wu K  Fei J  Hu S 《Analytical biochemistry》2003,318(1):100-106
A chemically modified electrode based on the carbon nanotube film-coated glassy carbon electrode (GCE) is described for the simultaneous determination of dopamine (DA) and serotonin (5-HT). The multiwall carbon nanotube (MWNT) film-coated GCE exhibits a marked enhancement effect on the current response of DA and 5-HT and lowers oxidation overpotentials. The responses of DA and 5-HT merge into a large peak at a bare GCE, but they yield two well-defined oxidation peaks at the MWNT film-coated GCE. The experimental parameters were optimized, and a direct electrochemical method for the simultaneous determination of DA and 5-HT was proposed. The interference of ascorbic acid (AA) was investigated, and the results showed that a large excess of AA did not interfere with the voltammetric responses of DA and 5-HT. The modified electrode has been successfully applied for the assay of 5-HT and DA in human blood serum.  相似文献   

13.
Two generic, fast, sensitive and novel electrochemical immunosensors have been developed. Initially, a layer of plasma-polymerized Nafion film (PPF) was deposited on the platinum electrode surface, then positively charged tris(2,2'-bipyridyl)cobalt(III) (Co(bpy)(3)(3+)) and negatively charged gold nanoparticles were assembled on the PPF-modified Pt electrode by layer-by-layer technique. Finally, hepatitis B surface antibody (HBsAb) was electrostatically adsorbed on the gold nanoparticles surface. Electrochemical behavior of the {Au/Co(bpy)(3)(3+)}(n) multilayer film-modified electrodes was studied. Cyclic voltammetry, electrochemical impedance spectroscopy (EIS) were adopted to monitor the regular growth of the multilayer films. The performance and factors influencing the performance of the resulting immunosensors were studied in detail. The multilayer film-modified immunosensor was used for hepatitis B surface antigen (HBsAg) determination via the amperometric and potentiometric immunosensor systems, and both systems provided the same linear ranges from 0.05 to 4.5 microg/mL with different detection limits for the amperometric system 0.005 microg/mL and for the potentiometric system 0.015 microg/mL. The immunosensors were used to analyse HBsAg in human serum samples. Analytical results of clinical samples show that the developed immunoassay is comparable with the enzyme-linked immunosorbent assays (ELISAs) method, implying a promising alternative approach for detecting HBsAg in the clinical diagnosis. In addition, the multilayer films also showed better stability for 1 month at least.  相似文献   

14.
This paper provides an overview of different nanostructured architectures utilised in electrochemical devices and their application in biosensing and bioelectronics. Emphasis is placed on the fabrication of nanostructured films based on a layer-by-layer (LBL) films approach. We discuss the theory and the mechanism of charge transfer in polyelectrolyte multilayer films (PEM), as well as between biomolecules and redox centres, for the development of more sensitive and selective biosensors. Further, this paper presents an overview of topics involving the interaction between nanostructured materials, including metallic nanoparticles and carbon materials, and their effects on the preservation of the activity of biological molecules immobilised on electrode surfaces. This paper also presents examples of biological molecules utilised in film fabrication, such as DNA, several kinds of proteins, and oligonucleotides, and of the role of molecular interaction in biosensing performance. Towards the utilisation of LBL films, examples of several architectures and different electrochemical approaches demonstrate the potential of nanostructured LBL films for several applications that include the diagnosis and monitoring of diseases. Our main aim in this review is to survey what can assist researchers by presenting various approaches currently used in the field of bioelectrochemistry utilising supramolecular architectures based on an LBL approach for application in electrochemical biosensing.  相似文献   

15.
A highly sensitive biosensor was developed based on bionanomultilyer with water-soluble carbon nanotubes (CNTs). The water-soluble poly(allylamine hydrochloride)-wrapped multiwall carbon nanotubes (PAH-MWNTs) can be obtained for the first time relying on the function of barbiturates, which provides a useful avenue for CNT application in material science and biosensor technology. Based on this, the PAH-MWNTs/horseradish peroxidase (HRP) bionanomultilayer was prepared via layer-by-layer (LBL) assembly. Electrochemical impedance spectroscopy, atomic force microscopy and UV-vis spectra were adopted to monitor the uniform LBL assembly of the homogeneous bionanomultilayer. The bionanomultilayer was used to construct a phenolic biosensor. Under the optimal conditions, the biosensor presented a linear response for catechol from 0.1 to 20.4muM, with a detection limit of 0.06muM. A series of phenolics were detected by the bionanomultilayer biosensor. The introduced MWNTs in the biosensor provided a suitable microenvironment to retain the HRP activity and acted as a transducer for amplifying the electrochemical signal of the product of the enzymatic reaction. So the developed bionanomultilayer biosensor exhibited a fast, sensitive and stable detection.  相似文献   

16.
The use of poly(acrylic acid) (PAA)-multiwalled carbon-nanotubes (MWNTs) composite-coated glassy-carbon disk electrode (GCE) (PAA-MWNTs/GCE) for the simultaneous determination of physiological level dopamine (DA) and uric acid (UA) in the presence of an excess of ascorbic acid (AA) in a pH 7.4 phosphate-buffered solution was proposed. PAA-MWNTs composite was prepared by mixing of MWNTs powder into 1 mg/ml PAA aqueous solution under sonication. GCE surface was modified with PAA-MWNTs film by casting. AA demonstrates no voltammetric peak at PAA-MWNTs/GCE. The PAA-MWNTs composite is of a high surface area and of affinity for DA and UA adsorption. DA exhibits greatly improved electron-transfer rate and is electro-catalyzed at PAA-MWNTs/GCE. Moreover, the electro-catalytic oxidation of UA at PAA-MWNTs/GCE is observed, which makes it possible to detect lower level UA. Therefore, the enhanced electrocatalytic currents for DA and UA were observed. The anodic peak currents at approximately 0.18 V and 0.35 V increase with the increasing concentrations of DA and UA, respectively, which correspond to the voltammetric peaks of DA and UA, respectively. The linear ranges are 40 nM to 3 microM DA and 0.3 microM to 10 microM UA in the presence of 0.3 mM AA. The lowest detection limits (S/N=3) were 20 nM DA and 110 nM UA.  相似文献   

17.
A disposable and sensitive screen-printed electrode using an ink containing graphene was developed. This electrode combined the advantages of graphene and the disposable characteristic of electrode, which possessed wide potential window, low background current and fast electron transfer kinetics. Compared with the electrodes made from other inks, screen-printed graphene electrode (SPGNE) showed excellent electrocatalytic activity for the oxidation of ascorbic acid (AA), dopamine (DA), and uric acid (UA). Three well-defined sharp and fully resolved anodic peaks were found at the developed electrode. Differential pulse voltammetry was used to simultaneous determination of AA, DA, and UA in their ternary mixture. In the co-existence system of these three species, the linear response ranges for the determination of AA, DA, and UA were 4.0-4500 μM, 0.5-2000 μM, and 0.8-2500 μM, respectively. The detection limits (S/N=3) were found to be 0.95 μM, 0.12 μM, and 0.20 μM for the determination of AA, DA, and UA, respectively. Furthermore, the SPGNE displayed high reproducibility and stability for these species determination. The feasibility of the developed electrode for real sample analysis was investigated. Results showed that the SPGNE could be used as a sensitive and selective sensor for simultaneous determination of AA, DA, and UA in biological samples, which may provide a promising alternative in routine sensing applications.  相似文献   

18.
Liu G  Chen H  Peng H  Song S  Gao J  Lu J  Ding M  Li L  Ren S  Zou Z  Fan C 《Biosensors & bioelectronics》2011,28(1):308-313
Carbon nanotubes have shown their unique advantages of mechanical, chemical and electronic properties in bioanalysis. We herein report a new method to efficiently and reproducibly prepare multi-walled carbon nanotubes (MWNTs)-protein sensing layers for electrochemical immunosensors. This method employs centrifugation to prepare a conjugate of MWNTs and goat anti mouse-immunoglobulin G (IgG) (secondary antibody). The conjugates were then deposited on screen-printed electrodes to form a nanostructured layer (MWNT-I layer). CLB monoclonal antibody was assembled through its binding to the secondary antibody. The MWNT-I layer-based electrodes were used for rapid and sensitive amperometric immunosensing detection of clenbuterol (CLB) in swine urine samples. Horseradish peroxidase-coupled CLB (CLB-HRP) competed with free CLB in the samples to bind the monoclonal antibody. It has shown significantly higher sensitivity and better reproducibility than the chemical conjugation method. This MWNT-based immunosensor is highly sensitive, leading to a limit of detection of 0.1 ng/mL within a rapid assay time of 16 min. Its sensitivity is at least 1 order of magnitude higher than that of a normal immunosensor (without MWNTs). The sensing device is portable with disposable screen-printed electrode, satisfactorily meeting the requirements for field detection of food security-related species.  相似文献   

19.
A high performance laccase‐based biofuel cell cathode is developed using carbon nanosheets (CNS) as the catalyst support and buckypaper (BP) as the substrate electrode. Compared to multiwalled carbon nanotube (MWNT)‐based electrodes, CNS‐based electrodes exhibit better electrochemical properties for the oxygen reduction reaction (ORR) under biologically relevant conditions. It is shown that CNSs are conformally coated on the nanotubule bundles within the BP and that laccase is intimately attached to the CNS‐BP. Electrochemical characterization is carried out to derive the kinetic parameters of the ORR at the laccase‐CNS‐BP cathode. The laccase‐CNS‐BP exhibits a steep ORR cathodic wave with a Tafel slope of 19 mV decade‐1. The onset potential obtained for laccase ORR at CNS‐BP is 20 mV higher than that of the MWNT‐based electrodes, and the laccase‐CNS‐BP cathode has a higher current density than MWNT electrodes.  相似文献   

20.
Jiang B  Defusco E  Li B 《Biomacromolecules》2010,11(12):3630-3637
The current state-of-the-art for drug-carrying biomedical devices is mostly limited to those that release a single drug. Yet there are many situations in which more than one therapeutic agent is needed. Also, most polyelectrolyte multilayer films intended for drug delivery are loaded with active molecules only during multilayer film preparation. In this paper, we present the integration of capsules as vehicles within polypeptide multilayer films for sustained release of multiple oppositely charged drug molecules using layer-by-layer nanoassembly technology. Calcium carbonate (CaCO(3)) particles were impregnated with polyelectrolytes, shelled with polyelectrolyte multilayers, and then assembled onto polypeptide multilayer films using glutaraldehyde. Capsule-integrated polypeptide multilayer films were obtained after decomposition of CaCO(3) templates. Two oppositely charged drugs were loaded into capsules within polypeptide multilayer films postpreparation based on electrostatic interactions between the drugs and the polyelectrolytes impregnated within capsules. We determined that the developed innovative capsule-integrated polypeptide multilayer films could be used to load multiple drugs of very different properties (e.g., opposite charges) any time postpreparation (e.g., minutes before surgical implantation inside an operating room), and such capsule-integrated films allowed simultaneous delivery of two oppositely charged drug molecules and a sustained (up to two weeks or longer) and sequential release was achieved.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号