首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The use of nLC-ESI-MS/MS in shotgun proteomics experiments and GeLC-MS/MS analysis is well accepted and routinely available in most proteomics laboratories. However, the same cannot be said for nLC-MALDI MS/MS, which has yet to experience such widespread acceptance, despite the fact that the MALDI technology offers several critical advantages over ESI. As an illustration, in an analysis of moderately complex sample of E. coli proteins, the use MALDI in addition to ESI in GeLC-MS/MS resulted in a 16% average increase in protein identifications, while with more complex samples the number of additional protein identifications increased by an average of 45%. The size of the unique peptides identified by MALDI was, on average, 25% larger than the unique peptides identified by ESI, and they were found to be slightly more hydrophilic. The insensitivity of MALDI to the presence of ionization suppression agents was shown to be a significant advantage, suggesting it be used as a complement to ESI when ion suppression is a possibility. Furthermore, the higher resolution of the TOF/TOF instrument improved the sensitivity, accuracy, and precision of the data over that obtained using only ESI-based iTRAQ experiments using a linear ion trap. Nevertheless, accurate data can be generated with either instrument. These results demonstrate that coupling nanoLC with both ESI and MALDI ionization interfaces improves proteome coverage, reduces the deleterious effects of ionization suppression agents, and improves quantitation, particularly in complex samples.  相似文献   

2.
The cystic fibrosis transmembrane conductance regulator (CFTR) gene encodes an apical membrane Cl- channel regulated by protein phosphorylation. To identify cAMP-dependent protein kinase (PKA)-phosphorylated residues in full-length CFTR, immobilized metal-ion affinity chromatography (IMAC) was used to selectively purify phosphopeptides. The greater specificity of iron-loaded (Fe3+) nitrilotriacetic (NTA). Sepharose compared to iminodiacetic acid (IDA) metal-chelating matrices was demonstrated using a PKA-phosphorylated recombinant NBD1-R protein from CFTR. Fe(3+)-loaded NTA Sepharose preferentially bound phosphopeptides, whereas acidic and poly-His-containing peptides were co-purified using the conventional IDA matrices. IMAC using NTA Sepharose enabled the selective recovery of phosphopeptides and identification of phosphorylated residues from a complex proteolytic digest. Phosphopeptides from PKA-phosphorylated full-length CFTR, generated in Hi5 insect cells using a baculovirus expression system, were purified using NTA Sepharose. Phosphopeptides were identified using matrix-assisted laser desorption mass spectrometry (MALDI/MS) with post-source decay (PSD) analysis and collision-induced dissociation (CID) experiments. Phosphorylated peptides were identified by mass and by the metastable loss of HPO3 and H3PO4 from the parent ions. Peptide sequence and phosphorylation at CFTR residues 660Ser, 737Ser, and 795Ser were confirmed using MALDI/PSD analysis. Peptide sequences and phosphorylation at CFTR residues 700Ser, 712Ser, 768Ser, and 813Ser were deduced from peptide mass, metastable fragment ion formation, and PKA consensus sequences. Peptide sequence and phosphorylation at residue 753Ser was confirmed using MALDI/CID analysis. This is the first report of phosphorylation of 753Ser in full-length CFTR.  相似文献   

3.
We demonstrate an approach for global quantitative analysis of protein mixtures using differential stable isotopic labeling of the enzyme-digested peptides combined with microbore liquid chromatography (LC) matrix-assisted laser desorption ionization (MALDI) mass spectrometry (MS). Microbore LC provides higher sample loading, compared to capillary LC, which facilitates the quantification of low abundance proteins in protein mixtures. In this work, microbore LC is combined with MALDI MS via a heated droplet interface. The compatibilities of two global peptide labeling methods (i.e., esterification to carboxylic groups and dimethylation to amine groups of peptides) with this LC-MALDI technique are evaluated. Using a quadrupole-time-of-flight mass spectrometer, MALDI spectra of the peptides in individual sample spots are obtained to determine the abundance ratio among pairs of differential isotopically labeled peptides. MS/MS spectra are subsequently obtained from the peptide pairs showing significant abundance differences to determine the sequences of selected peptides for protein identification. The peptide sequences determined from MS/MS database search are confirmed by using the overlaid fragment ion spectra generated from a pair of differentially labeled peptides. The effectiveness of this microbore LC-MALDI approach is demonstrated in the quantification and identification of peptides from a mixture of standard proteins as well as E. coli whole cell extract of known relative concentrations. It is shown that this approach provides a facile and economical means of comparing relative protein abundances from two proteome samples.  相似文献   

4.
Liquid chromatography MALDI MS/MS for membrane proteome analysis   总被引:3,自引:0,他引:3  
Membrane proteins play critical roles in many biological functions and are often the molecular targets for drug discovery. However, their analysis presents a special challenge largely due to their highly hydrophobic nature. We present a surfactant-aided shotgun proteomics approach for membrane proteome analysis. In this approach, membrane proteins were solubilized and digested in the presence of SDS followed by newly developed auto-offline liquid chromatography/matrix-assisted laser desorption ionization (LC/MALDI) tandem MS analysis. Because of high tolerance of MALDI to SDS, one-dimensional (1D) LC separation can be combined with MALDI for direct analysis of protein digests containing SDS, without the need for extensive sample cleanup. In addition, the heated droplet interface used in LC/MALDI can work with high flow LC separations, allowing a relatively large amount of protein digest to be used for 1D LC/MALDI which facilitates the detection of low abundance proteins. The proteome identification results obtained by LC/MALDI are compared to the gel electrophoresis/MS method as well as the shotgun proteomics method using 2D LC/electrospray ionization MS. It is demonstrated that, while LC/MALDI provides more extensive proteome coverage compared to the other two methods, these three methods are complementary to each other and a combination of these methods should provide a more comprehensive membrane proteome analysis.  相似文献   

5.
Tristetraprolin (TTP) is a member of the CCCH zinc finger proteins and is an anti-inflammatory protein. Mice deficient in TTP develop a profound inflammatory syndrome with erosive arthritis, autoimmunity and myeloid hyperplasia. TTP binds to mRNA AU-rich elements with high affinity for UUAUUUAUU nucleotides and causes destabilization of those mRNA molecules. TTP is phosphorylated extensively in vivo and is a substrate for multiple protein kinases in vitro. A number of approaches have been used to identify its phosphorylation sites. This article highlights the recent progress and different approaches utilized for the identification of phosphorylation sites in mammalian TTP. Important but limited results are obtained using traditional methods, including in vivo labeling, site-directed mutagenesis, phosphopeptide mapping and protein sequencing. Mass spectrometry (MS), including MALDI/MS, MALDI/MS/MS, liquid chromatography/MS/MS, immobilized metal ion affinity chromatography (IMAC)/MALDI/MS/MS and multidimensional protein identification technology has led the way in identifying TTP phosphorylation sites. The combination of these approaches has identified multiple phosphorylation sites in mammalian TTP, some of which are predicted by motif scanning to be phosphorylated by several protein kinases. This information should provide the molecular basis for future investigation of TTP’s regulatory functions in controlling proinflammatory cytokines.  相似文献   

6.
The quality of MALDI‐TOF mass spectrometric analysis is highly dependent on the matrix and its deposition strategy. Although different matrix‐deposition methods have specific advantages, one major problem in the field of proteomics, particularly with respect to quantitation, is reproducibility between users or laboratories. Compounding this is the varying crystal homogeneity of matrices depending on the deposition strategy used. Here, we describe a novel optimised matrix‐deposition strategy for LC‐MALDI‐TOF/TOF MS using an automated instrument that produces a nebulised matrix “mist” under controlled atmospheric conditions. Comparisons of this with previously reported strategies showed the method to be advantageous for the atypical matrix, 2,5‐DHB, and improved phosphopeptide ionisation when compared with deposition strategies for CHCA. This optimised DHB matrix‐deposition strategy with LC‐MALDI‐TOF/TOF MS, termed EZYprep LC, was subsequently optimised for phosphoproteome analysis and compared to LC‐ESI‐IT‐MS and a previously reported approach for phosphotyrosine identification and characterisation. These methods were used to map phosphorylation on epidermal growth factor‐stimulated epidermal growth factor receptor to gauge the sensitivity of the proposed method. EZYprep DHB LC‐MALDI‐TOF/TOF MS was able to identify more phosphopeptides and characterise more phosphorylation sites than the other two proteomic strategies, thus proving to be a sensitive approach for phosphoproteome analysis.  相似文献   

7.
A group of coagulase negative staphylococcal strains isolated from indoor air of occupied school rooms were the subject of this study. Conventional MALDI TOF MS profiling of cellular extracts and physiological tests (including API STAPH) provided incomplete identification of the set of strains. After separation of a 100 kDa band using 1D gel electrophoresis, profiling of peptides (released with tryptic digestion) using MALDI TOF MS allowed improved bacterial speciation in addition to determination of the identity of the protein of origin (aconitate hydratase). This was performed by Mascot search, empirical observation and computer-generated cross-correlation analysis of environmental isolates versus reference strains. The species studied included some with sequenced genomes and others with un-sequenced genomes. Peptide sequences were confirmed to originate from aconitate hydratase using MALDI TOF-TOF MS-MS analysis of a diverse set of m/z values representing variable and conserved sequences. The methodological approach described here might have widespread application in speciation of environmental isolates of diverse origin and in identification of their expressed proteins.  相似文献   

8.
Cramer R  Corless S 《Proteomics》2005,5(2):360-370
We have combined several key sample preparation steps for the use of a liquid matrix system to provide high analytical sensitivity in automated ultraviolet -- matrix-assisted laser desorption/ionisation -- mass spectrometry (UV-MALDI-MS). This new sample preparation protocol employs a matrix-mixture which is based on the glycerol matrix-mixture described by Sze et al. The low-femtomole sensitivity that is achievable with this new preparation protocol enables proteomic analysis of protein digests comparable to solid-state matrix systems. For automated data acquisition and analysis, the MALDI performance of this liquid matrix surpasses the conventional solid-state MALDI matrices. Besides the inherent general advantages of liquid samples for automated sample preparation and data acquisition the use of the presented liquid matrix significantly reduces the extent of unspecific ion signals in peptide mass fingerprints compared to typically used solid matrices, such as 2,5-dihydroxybenzoic acid (DHB) or alpha-cyano-hydroxycinnamic acid (CHCA). In particular, matrix and low-mass ion signals and ion signals resulting from cation adduct formation are dramatically reduced. Consequently, the confidence level of protein identification by peptide mass mapping of in-solution and in-gel digests is generally higher.  相似文献   

9.
We report the development of a robust interface for off-line coupling of nano liquid chromatography (LC) to matrix-assisted laser desorption/ionisation-mass spectrometry (MALDI-MS) and its application to the analysis of proteolytic digests of proteins, both isolated and in mixtures. The interface makes use of prestructured MALDI sample supports to concentrate the effluent to a small sample plate area and localize the MALDI sample to a predefined array, thereby enriching the analyte molecules and facilitating automated MALDI-MS analysis. Parameters that influence the preparation of MALDI samples from the LC effluent were evaluated with regard to detection sensitivity, spectra quality, and reproducibility of the method. A procedure for data processing is described. The presented nano LC MALDI-MS system allowed the detection of several peptides from a tryptic digest of bovine serum albumin, at analyzed amounts corresponding to one femtomole of the digested protein. For the identification of native proteins isolated from mouse brain by two-dimensional gel electrophoresis, nano LC MALDI-MS increased the number of detected peptides, thereby allowing identification of proteins that could not be identified by direct MALDI-MS analysis. The ability to identify proteins in complex mixtures was evaluated for the analysis of Escherichia coli 50S ribosomal subunit. Out of the 33 expected proteins, 30 were identified by MALDI tandem time of flight fragment ion fingerprinting.  相似文献   

10.
Autosomal recessive polycystic kidney disease (ARPKD) is a severe, monogenetically inherited kidney and liver disease. PCK rats carrying the orthologous mutant gene serve as a model of human disease, and alterations in lipid profiles in PCK rats suggest that defined subsets of lipids may be useful as molecular disease markers. Whereas MALDI protein imaging mass spectrometry (IMS) has become a promising tool for disease classification, widely applicable workflows that link MALDI lipid imaging and identification as well as structural characterization of candidate disease-classifying marker lipids are lacking. Here, we combine selective MALDI imaging of sulfated kidney lipids and Fisher discriminant analysis (FDA) of imaging data sets for identification of candidate markers of progressive disease in PCK rats. Our study highlights strong increases in lower mass lipids as main classifiers of cystic disease. Structure determination by high-resolution mass spectrometry identifies these altered lipids as taurine-conjugated bile acids. These sulfated lipids are selectively elevated in the PCK rat model but not in models of related hepatorenal fibrocystic diseases, suggesting that they be molecular markers of the disease and that a combination of MALDI imaging with high-resolution MS methods and Fisher discriminant data analysis may be applicable for lipid marker discovery.  相似文献   

11.
Matrix-assisted laser desorption and ionization time-of-flight mass spectrometry (MALDI-TOF MS) has been recently established as a powerful tool for the analysis of biomolecules. Here, MALDI-TOF MS was used for the detection of (poly-)phosphoinositides (PPI). PPI possess higher molecular weights than other phospholipids and a high phosphorylation-dependent negative charge. Both features affect the MALDI detection limits expressed as the minimum of analyte on the sample plate resulting in a signal-to-noise-ratio of S/N=5. Using 2,5-dihydroxybenzoic acid (DHB) as matrix the detection limit for phosphatidylinositol (PI) is seven times higher than for phosphatidylcholine (PC) and further increases with increasing phosphorylation or in mixtures with other well-detectable phospholipids. For phosphatidylinositol-tris-phosphate (PIP3) in a mixture with PC, the limit is about 20 times higher than for PI. The consequences for the experimental conditions are discussed. It is advisable to pre-separate PPI from biological lipid mixtures prior to the application of MALDI-TOF MS.  相似文献   

12.
The identification of proteins separated on two-dimensional gels is most commonly performed by trypsin digestion and subsequent matrix-assisted laser desorption ionization (MALDI) with time-of-flight (TOF). Recently, atmospheric pressure (AP) MALDI coupled to an ion trap (IT) has emerged as a convenient method to obtain tandem mass spectra (MS/MS) from samples on MALDI target plates. In the present work, we investigated the feasibility of using the two methodologies in line as a standard method for protein identification. In this setup, the high mass accuracy MALDI-TOF spectra are used to calibrate the peptide precursor masses in the lower mass accuracy AP-MALDI-IT MS/MS spectra. Several software tools were developed to automate the analysis process. Two sets of MALDI samples, consisting of 142 and 421 gel spots, respectively, were analyzed in a highly automated manner. In the first set, the protein identification rate increased from 61% for MALDI-TOF only to 85% for MALDI-TOF combined with AP-MALDI-IT. In the second data set the increase in protein identification rate was from 44% to 58%. AP-MALDI-IT MS/MS spectra were in general less effective than the MALDI-TOF spectra for protein identification, but the combination of the two methods clearly enhanced the confidence in protein identification.  相似文献   

13.
The performances of five different ESI sources coupled to a polystyrene–divinylbenzene monolithic column were compared in a series of LC‐ESI‐MS/MS analyses of Escherichia coli outer membrane proteins. The sources selected for comparison included two different modifications of the standard electrospray source, a commercial low‐flow sprayer, a stainless steel nanospray needle and a coated glass Picotip. Respective performances were judged on sensitivity and the number and reproducibility of significant protein identifications obtained through the analysis of multiple identical samples. Data quality varied between that of a ground silica capillary, with 160 total protein identifications, the lowest number of high quality peptide hits obtained (3012), and generally peaks of lower intensity; and a stainless steel nanospray needle, which resulted in increased precursor ion abundance, the highest‐quality peptide fragmentation spectra (5414) and greatest number of total protein identifications (259) exhibiting the highest MASCOT scores (average increase in score of 27.5% per identified protein). The data presented show that, despite increased variability in comparative ion intensity, the stainless steel nanospray needle provides the highest overall sensitivity. However, the resulting data were less reproducible in terms of proteins identified in complex mixtures – arguably due to an increased number of high intensity precursor ion candidates.  相似文献   

14.
A novel, MS-based approach for the relative quantification of proteins, relying on the derivatization of primary amino groups in intact proteins using isobaric tag for relative and absolute quantitation (iTRAQ) is presented. Due to the isobaric mass design of the iTRAQ reagents, differentially labeled proteins do not differ in mass; accordingly, their corresponding proteolytic peptides appear as single peaks in MS scans. Because quantitative information is provided by isotope-encoded reporter ions that can only be observed in MS/MS spectra, we analyzed the fragmentation behavior of ESI and MALDI ions of peptides generated from iTRAQ-labeled proteins using a TOF/TOF and/or a QTOF instrument. We observed efficient liberation of reporter ions for singly protonated peptides at low-energy collision conditions. In contrast, increased collision energies were required to liberate the iTRAQ label from lysine side chains of doubly charged peptides and, thus, to observe reporter ions suitable for relative quantification of proteins with high accuracy. We then developed a quantitative strategy that comprises labeling of intact proteins by iTRAQ followed by gel electrophoresis and peptide MS/MS analyses. As proof of principle, mixtures of five different proteins in various concentration ratios were quantified, demonstrating the general applicability of the approach presented here to quantitative MS-based proteomics.  相似文献   

15.
Integrating surface plasmon resonance analysis with mass spectrometry allows detection and characterization of molecular interactions to be complemented with identification of interaction partners. We have developed a procedure for Biacore 3000 that automatically performs all steps from ligand fishing and recovery to sample preparation for matrix-assisted laser desorption/ionization (MALDI) mass spectrometry including on-target digestion. In the model system used in this study a signal transduction protein, calmodulin, was selectively captured from brain extract by one of its interaction partners immobilized on a sensor chip. The bound material was eluted, deposited directly onto a MALDI target, and analyzed by mass spectrometry both as an intact protein and after on-target tryptic digestion. The procedure with direct deposition of recovered material on the MALDI target reduces sample losses and, in combination with automatic sample processing, increases the throughput of surface plasmon resonance mass spectrometry analysis.  相似文献   

16.
Zhou H  Xu S  Ye M  Feng S  Pan C  Jiang X  Li X  Han G  Fu Y  Zou H 《Journal of proteome research》2006,5(9):2431-2437
Phosphorylation is one of the most important post-translational modifications of proteins, which modulates a wide range of biological functions and activity of proteins. The analysis of phosphopeptides is still one of the most challenging tasks in proteomics research by mass spectrometry. In this study, a novel phosphopeptide enrichment approach based on the strong interaction of zirconium phosphonate (ZrP) modified surface with phosphopeptides has been developed. ZrP modified porous silicon (ZrP-pSi) wafer was prepared to specifically capture the phosphopeptides from complex peptide mixtures, and then the captured phosphopeptides were analyzed by MALDI-TOF MS by directly placing the wafer on a MALDI target. The phosphopeptide enrichment and MALDI analysis were both performed on the ZrP-pSi wafer which significantly reduced the sample loss and simplified the analytical procedures. The prepared ZrP-pSi wafer has been successfully applied for the enrichment of phosphopeptides from the tryptic digest of standard phosphoproteins beta-casein and alpha-casein. The excellent selectivity of this approach was demonstrated by analyzing phosphopeptides in the digest mixture of beta-casein and bovine serum albumin with molar ratio of 1:100. High detection sensitivity has been achieved for the analysis of the phosphopeptides from tryptic digestion of 2 fmol beta-casein on the ZrP-pSi surface.  相似文献   

17.
This article is the first in a series of reviews intended as a tutorial providing the inexperienced, as well as the experienced, reader with an overview of principles of peptide and protein fragmentation in mass spectrometers for protein identification, surveying of the different types of instrument configurations and their combinations for protein identification. The first mass spectrometer was developed in 1899, but it took almost a century for the instrument to become a routine analytical method in proteomic research when fast atom bombardment ionization was developed, followed shortly by soft desorption/ionization methods, such as MALDI and electrospray ionization, to volatize biomolecules with masses of tens of kiloDaltons into the gas phase under vacuum pressure without destroying them. Thereafter, other soft ionization techniques that offered ambient conditions were also introduced, such as atmospheric pressure MALDI, direct analysis in real time, atmospheric-pressure solid analysis probe and hybrid ionization, sources of MALDI and electrospray ionization (e.g., two-step fused droplet electrospray ionization, laser desorption atmospheric-pressure chemical ionization, electrosonic spray ionization, desorption electrospray ionization, and electrospray-assisted laser desorption/ionization). The five basic types of mass analyzers currently used in proteomic research are the quadrupole, ion trap, orbitrap, Fourier transform ion cyclotron resonance and TOF instruments, which differ in how they determine the mass-to-charge ratios of the peptides. They have very different design and performance characteristics. These analyzers can be stand alone or, in some cases, put together in tandem or in conjunction with ion mobility mass spectrometry to take advantage of the strengths of each. Several singly or multiply charged fragment ion types, such as b, y, a, c, z, v, y and immonium ions are produced in the gas phase of the spectrometer. In the bottom-up sequencing approach for protein identification in a shotgun proteomic experiment, proteolytic digestion of proteins is accomplished by cleavage of the different bonds along the peptide backbone and/or side chain through a charge-directed transfer to the vicinity of the cleavage side. These various mass spectrometers and the types of ions produced have become important analytical tools for studying and analyzing proteins, peptides and amino acids.  相似文献   

18.
Neuronal membrane phospholipids are highly affected by oxidative stress caused by ischemic injury. Thus, it is necessary to identify key lipid components that show changes during ischemia to develop an effective approach to prevent brain damage from ischemic injury. The recent development of MALDI imaging MS (MALDI IMS) makes it possible to identify phospholipids that change between damaged and normal regions directly from tissues. In this study, we conducted IMS on rat brains damaged by ischemic injury and detected various phospholipids that showed unique distributions between normal and damaged areas of the brain. Among them, we confirmed changes in phospholipids such as lysophosphatidylcholine, phosphatidylcholine, phosphatidylethanolamine, and sphingomyelin by MALDI IMS followed by MS/MS analysis. These lipids were present in high concentrations in the brain and are important for maintenance of cellular structure as well as production of second messengers for cellular signal transduction. Our results emphasize the identification of phospholipid markers for ischemic injury and successfully identified several distinctly located phospholipids in ischemic brain tissue.  相似文献   

19.
The combination of high accuracy, sensitivity and speed of single and multiple-stage mass spectrometric analyses enables the collection of comprehensive sets of data containing detailed information about complex biological samples. To achieve these properties, we combined two high-performance matrix-assisted laser desorption ionization mass analyzers in one modular mass spectrometric tool, and applied this tool for dissecting the composition and post-translational modifications of protein complexes. As an example of this approach, we here present studies of the Saccharomyces cerevisiae anaphase-promoting complexes (APC) and elucidation of phosphorylation sites on its components. In general, the modular concept we describe could be useful for assembling mass spectrometers operating with both matrix-assisted laser desorption ionization (MALDI) and electrospray ionization (ESI) ion sources into powerful mass spectrometric tools for the comprehensive analysis of complex biological samples.  相似文献   

20.
Tristetraprolin (TTP) is a member of the CCCH zinc finger proteins and is an anti-inflammatory protein. Mice deficient in TTP develop a profound inflammatory syndrome with erosive arthritis, autoimmunity and myeloid hyperplasia. TTP binds to mRNA AU-rich elements with high affinity for UUAUUUAUU nucleotides and causes destabilization of those mRNA molecules. TTP is phosphorylated extensively in vivo and is a substrate for multiple protein kinases in vitro. A number of approaches have been used to identify its phosphorylation sites. This article highlights the recent progress and different approaches utilized for the identification of phosphorylation sites in mammalian TTP. Important but limited results are obtained using traditional methods, including in vivo labeling, site-directed mutagenesis, phosphopeptide mapping and protein sequencing. Mass spectrometry (MS), including MALDI/MS, MALDI/MS/MS, liquid chromatography/MS/MS, immobilized metal ion affinity chromatography (IMAC)/MALDI/MS/MS and multidimensional protein identification technology has led the way in identifying TTP phosphorylation sites. The combination of these approaches has identified multiple phosphorylation sites in mammalian TTP, some of which are predicted by motif scanning to be phosphorylated by several protein kinases. This information should provide the molecular basis for future investigation of TTP's regulatory functions in controlling proinflammatory cytokines.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号