首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A rapid and sensitive method was developed for the simultaneous determination of the new doxorubicin glucuronide prodrug HMR 1826, the parent drug doxorubicin and its metabolites in human lung tissue samples. Homogenization of frozen tissue samples with the micro-dismembrator was followed by a silver nitrate precipitation step. By removing the exceeding silver ions with sodium chloride further purification steps could be omitted. Compounds were separated by isocratic high-performance liquid chromatography on a LiChrospher 100 RP18 column and a mobile phase consisting of citric acid buffer–acetonitrile–methanol–tetrahydrofuran within 30 min and quantified with fluorescence detection. The method showed good recoveries for all compounds (86–99%) and a linear calibration range of 20 ng/g–80 μg/g for doxorubicin and 1–600 μg/g for HMR 1826.  相似文献   

2.
A high-performance liquid chromatographic method has been developed and tested for simultaneous extraction, elution and determination of doxorubicin and prochlorperazine content in human plasma samples. The procedure consists of extraction through a conditioned C18 solid-phase extraction cartridge, elution from a Spherisorb C8 reversed-phase column by an isocratic mobile phase (60% acetonitrile, 15% methanol and 25% buffer) followed by detection with electrochemical and fluorescence detectors. Recovery of doxorubicin and prochlorperazine from pooled human plasma samples (n=3) containing 100 ng/ml of the two drugs was 77.8±3.5% and 89.1±6.0%, respectively. The lower limits of quantitation for doxorubicin and prochlorperazine in plasma samples were 6.25 ng/ml and 10 ng/ml, respectively. A linear calibration curve was obtained for up to 2 μg/ml of doxorubicin and prochlorperazine. This combination method may be of particular value in clinical studies where phenothiazines such as prochlorperazine are used to enhance retention of doxorubicin in drug resistant tumor cells.  相似文献   

3.
A highly sensitive and selective method for determining 8-oxoguanine in plasma and urine was developed by high-performance liquid chromatography with electrochemical detection. The compound was separated by gradient elution on a C18 reversed-phase column with a mobile phase of acetonitrile and 0.1 M sodium acetate, pH 5.2. 8-Hydroxy-2′-deoxyguanosine was used as internal standard. 8-Oxoguanine was detected electrochemically by setting the potential to +300 mV vs. Pd reference. The sensitivity of the assay was 22 ng/ml with a signal-to-noise ratio of 7:1. The within-day relative standard deviations for 8-oxoguanine quality control samples with concentrations of 3340, 1340 and 84 ng/ml were 3.6, 4.3 and 5.7% for plasma, and 4.1, 4.6 and 6.2% for urine, respectively. The day-to-day relative standard deviations for the same samples were 3.8, 6.8 and 7.1% for plasma, and 3.9, 7.0 and 7.9% for urine, respectively. The method is designed to study the pharmacokinetics and metabolic fate of O6-benzylguanine in a phase I clinical trial. Previously, O6-benzyl-8-oxoguanine was identified as the primary metabolite of O6-benzylguanine in humans. We now demonstrate that 8-oxoguanine is a further metabolite of O6-benzylguanine.  相似文献   

4.
A sensitive and very specific method, using liquid chromatography–electrospray mass spectrometry (LC–ES-MS), was developed for the determination of epirubicin, doxorubicin, daunorubicin, idarubicin and the respective active metabolites of the last three, namely doxorubicinol, daunorubicinol and idarubicinol in human serum, using aclarubicin as internal standard. Once thawed, 0.5-ml serum samples underwent an automated solid-phase extraction, using C18 Bond Elut cartridges (Varian) and a Zymark Rapid-Trace robot. After elution of the compounds with chloroform–2-propanol (4:1, v/v) and evaporation, the residue was reconstituted with a mixture of 5 mM ammonium formate buffer (pH 4.5)–acetonitrile (60:40, v/v). The chromatographic separation was performed using a Symmetry C18, 3.5 μm (150×1 mm I.D.) reversed-phase column, and a mixture of 5 mM ammonium formate buffer (pH 3)–acetonitrile (70:30, v/v) as mobile phase, delivered at 50 μl/min. The compounds were detected in the selected ion monitoring mode using, as quantitation ions, m/z 291 for idarubicin and idarubicinol, m/z 321 for daunorubicin and daunorubicinol, m/z 361 for epirubicin and doxorubicin, m/z 363 for doxorubicinol and m/z 812 for aclarubicin (I.S.). Extraction recovery was between 71 and 105% depending on compounds and concentration. The limit of detection was 0.5 ng/ml for daunorubicin and idarubicinol, 1 ng/ml for doxorubicin, epirubicin and idarubicin, 2 ng/ml for daunorubicinol and 2.5 ng/ml for doxorubicinol. The limit of quantitation (LOQ) was 2.5 ng/ml for doxorubicin, epirubicin and daunorubicinol, and 5 ng/ml for daunorubicin, idarubicin, doxorubicinol and idarubicinol. Linearity was verified from these LOQs up to 2000 ng/ml for the parent drugs (r≥0.992) and 200 ng/ml for the active metabolites (r≥0.985). Above LOQ, the within-day and between-day precision relative standard deviation values were all less than 15%. This assay was applied successfully to the analysis of human serum samples collected in patients administered doxorubicin or daunorubicin intravenously. This method is rapid, reliable, allows an easy sample preparation owing to the automated extraction and a high selectivity owing to MS detection.  相似文献   

5.
A rapid, selective and sensitive method for the simultaneous determination of chlorpromazine and levomepromazine in human plasma and urine has been developed using high-performance liquid chromatography with electrochemical detection.The unchanged drugs and internal standard extracted from plasma and urine were separated by reversed-phase high-performance liquid chromatography. The influence of acetonitrile concentration and of the pH of the mobile phase were investigated. The detection limits were 100 pg for chlorpromazine and for levomepromazine. In comparison with three other detection systems this was found to be the most sensitive method.This method was successfully applied to the simultaneous determination of chlorpromazine and levomepromazine in human plasma and urine for pharmacokinetic studies.  相似文献   

6.
A rapid and simple method was developed for the separation and quantification of the anti nerve agent drug pyridostignmine bromide (PB; 3-dimethylaminocarbonyloxy-N-methyl pyridinium bromide) its metabolite N-methyl-3-hydroxypyridinium bromide, the insect repellent DEET (N,N-diethyl-m-toluamide), its metabolites m-toluamide and m-toluic acid, the insecticide permethrin (3-(2,2-dichloro-ethenyl)-2,2-dimethylcyclopropanecarboxylic acid(3-phenoxyphenyl)methylester), and two of its metabolites m-phenoxybenzyl alcohol, and m-phenoxybenzoic acid in rat plasma and urine. The method is based on using C18 Sep-Pak® cartridges for solid-phase extraction (SPE) and high-performance liquid chromatography (HPLC) with reversed-phase C18 column, and gradient UV detection ranging between 208 and 230 nm. The compounds were separated using gradient of 1 to 99% acetonitrile in water (pH 3.20) at a flow-rate ranging between 0.5 and 1.7 ml/min in a period of 17 min. The retention times ranged from 5.7 to 14.5 min. The limits of detection were ranged between 20 and 100 ng/ml, while limits of quantitation were 150–200 ng/ml. Average percentage recovery of five spiked plasma samples were 51.4±10.6, 71.1±11.0, 82.3±6.7, 60.4±11.8, 63.6±10.1, 69.3±8.5, 68.3±12.0, 82.6±8.1, and from urine 55.9±9.8, 60.3±7.4, 77.9±9.1, 61.7±13.5, 68.6±8.9, 62.0±9.5, 72.9±9.1, and 72.1±8.0, for pyridostigmine bromide, DEET, permethrin, N-methyl-3-hydroxypyridinium bromide, m-toluamide, m-toluic acid, m-phenoxybenzyl alcohol and m-phenoxybenzoic acid, respectively. The relationship between peak areas and concentration was linear over the range between 100 and 5000 ng/ml. This method was applied to analyze the above chemicals and metabolites following their administration in rats.  相似文献   

7.
A high-performance liquid chromatographic (HPLC) method for the simultaneous determination of cilostazol, a quinolinone derivative, and its known metabolites OPC-13015, OPC-13213, OPC-13217, OPC-13366, OPC-13269, OPC-13326 and OPC-13388 in human plasma was developed and validated. Cilostazol, its metabolites and two internal standards, OPC-3930 and OPC-13112, were extracted from human plasma by a combination of liquid–liquid and liquid–solid phase extractions, with combined organic solvents of n-butanol, methanol, chloroform, methyl-tert.-butyl ether, and a Sep-Pak silica column. The combined extract was then evaporated and the residue was reconstituted in ammonium acetate buffer (pH 6.5). The reconstituted solution was injected onto a HPLC system and was subjected to reversed-phase HPLC on a 5 μm ODS-80TM column to obtain quality chromatograph and good peak resolution. A gradient mobile phase with different percentages of acetonitrile in acetate buffer (pH 6.5) was used for the resolution of analytes. Cilostazol, its metabolites and the two internal standards were well separated at baseline from each other with resolution factor being 74 and 138. This HPLC method was demonstrated to be specific for all analytes of interest with no significant interference from the endogenous substances of human plasma. The lower limit of quantitation was 20 ng/ml for cilostazol and all metabolites. The method was validated initially for an extended linear range of 20–600 ng/ml for all metabolites and cilostazol, and has been revised later for a linear range of 20–1200 ng/ml for cilostazol and two major and active metabolites OPC-13015 and OPC-13213. The overall accuracy (relative recovery) of this method was established to be 98.5% to 104.9% for analytes with overall precision (CV) being 1.5% to 9.0%. The long-term stability of clinical plasma samples was established for at least one year at −20°C. Two internal standards of OPC-3930 and OPC-13112 were evaluated and validated. However, the data indicated that there was no significant difference for all accuracy and precision obtained by using either OPC-3930 or OPC-13112. OPC-3930 was chosen as the internal standard for the analysis of plasma samples from clinical studies due to its shorter retention time. During the validation standard curves had correlation coefficients greater than or equal to 0.998 for cilostazol and the seven metabolites. These data clearly demonstrate the reliability and reproducibility of the method.  相似文献   

8.
A method based on high-performance liquid chromatography (HPLC) with a diode array detection system was developed and validated aiming at the simultaneous determination of oleuropein (OE) and its metabolites, hydroxytyrosol (HT) and tyrosol (T), in human plasma. These phenolic components are believed to play a vital role in the prevention of coronary artery disease and atherosclerosis. The proposed method includes a clean-up solid-phase extraction procedure (using a C(18) column) with high recovery efficiency (85-100%). The statistical evaluation of the method reveals good linearity, accuracy and reproducibility for all the compounds analyzed with RSD values less than 6.5%, while the detection limit is 50 ng/ml for both OE and T and 75 ng/ml for HT. This assay can be employed in bioavailability studies of olive oil phenolic compounds, thus assisting the evaluation of their pharmacological role.  相似文献   

9.
A sensitive and rapid method for measuring simultaneously adenosine, S-adenosylhomocysteine and S-adenosylmethionine in renal tissue, and for the analysis of adenosine and S-adenosylhomocysteine concentrations in the urine is presented. Separation and quantification of the nucleosides are performed following solid-phase extraction by reversed-phase ion-pair high-performance liquid chromatography with a binary gradient system. N6-Methyladenosine is used as the internal standard. This method is characterized by an absolute recovery of over 90% of the nucleosides plus the following limits of quantification: 0.25–1.0 nmol/g wet weight for renal tissue and 0.25–0.5 μM for urine. The relative recovery (corrected for internal standard) of the three nucleosides ranges between 98.1±2.6% and 102.5±4.0% for renal tissue and urine, respectively (mean±S.D., n=3). Since the adenosine content in kidney tissue increases instantly after the onset of ischemia, a stop freezing technique is mandatory to observe the tissue levels of the nucleosides under normoxic conditions. The resulting tissue contents of adenosine, S-adenosylhomocysteine and S-adenosylmethionine in normoxic rat kidney are 5.64±2.2, 0.67±0.18 and 46.2±1.9 nmol/g wet weight, respectively (mean±S.D., n=6). Urine concentrations of adenosine and S-adenosylhomocysteine of man and rat are in the low μM range and are negatively correlated with urine flow-rate.  相似文献   

10.
A method was developed for the separation and quantification of the insecticide chlorpyrifos (O,O-diethyl-O[3,5,6-trichloro-2-pyridinyl] phosphorothioate), its metabolites chlorpyrifos-oxon (O,O-diethyl-O[3,5,6-trichloro-2-pyridinyl] phosphate) and TCP (3,5,6-trichloro-2-pyridinol), the anti-nerve agent drug pyridostigmine bromide (PB; 3-dimethylaminocarbonyloxy-N-methyl pyridinium bromide), its metabolite N-methyl-3-hydroxypyridinium bromide, the insect repellent DEET (N,N-diethyl-m-toluamide), and its metabolites m-toluamide and m-toluic acid in rat plasma and urine. The method is based on using solid-phase extraction and high-performance liquid chromatography (HPLC) with reversed-phase C18 column, and gradient UV detection ranging between 210 and 280 nm. The compounds were separated using a gradient of 1–85% acetonitrile in water (pH 3.20) at a flow-rate ranging between 1 and 1.7 ml/min over a period of 15 min. The retention times ranged from 5.4 to 13.2 min. The limits of detection ranged between 20 and 150 ng/ml, while the limits of quantitation were between 150 and 200 ng/ml. Average percentage recovery of five spiked plasma samples was 80.2±7.9, 74.9±8.5, 81.7±6.9, 73.1±7.8, 74.3±8.3, 80.8±6.6, 81.6±7.3 and 81.4±6.5, and from urine 79.4±6.9, 77.8±8.4, 83.3±6.6, 72.8±9.0, 76.3±7.7, 83.4±7.9, 81.6±7.9 and 81.8±6.8 for chlorpyrifos, chlorpyrifos-oxon, TCP, pyridostigmine bromide, N-methyl-3-hydroxypyridinium bromide, DEET, m-toluamide and m-toluic acid, respectively. The relationship between peak areas and concentration was linear over a range between 200 and 2000 ng/ml.  相似文献   

11.
The antioxidants, 2-tert.-butyl-4-methoxyphenol (BHA) and its oxidative peroxidation product 2,2′-dihydroxy-3,3′-di-tert.-butyl-5,5′-dimethoxybiphenyl (di-BHA), 3,5-di-tert.-butyl-4-hydroxytoluene (BHT) and propyl gallate, were measured in plasma and tissue homogenates by HPLC and electrochemical detection, with a sensitivity down to 0.2 (BHA), 0.1 (di-BHA), 0.4 (BHT) and 1 (propyl gallate) ng ml−1 of plasma or tissue homogenate. The data demonstrate that in man, at the current level of exposure to dietary antioxidants, significant amounts of BHA, BHT and propyl gallate are accumulated in the omentum. Furthermore, they provide the first evidence that the peroxidase-catalysed oxidation of BHA is operative in man.  相似文献   

12.
Quinupristin–dalfopristin (30:70, w/w) is a new streptogramin, which has been developed for intravenous use. A specific and sensitive HPLC method was developed to measure simultaneously quinupristin (RP 57669) and dalfopristin (RP 54476) and their main metabolites in human plasma. The metabolites measured by this method were RP 69012 (glutathione-conjugated) and RPR 100391 (cysteine-conjugated) from quinupristin and RP 12536 (natural pristinamycin IIA), from dalfopristin. Solid-phase extraction with disposable cartridges was combined with reversed-phase HPLC and fluorimetric detection for RP 57669, RP 69012 and RPR 100391 and UV detection for RP 54476 and RP 12536. The method provided good recovery and low limits of quantitation (0.025 mg l−1 for RP 57669, RP 54476 and RP 12536, and of 0.010 mg l−1 for RP 69012 and RPR 100391). The validated range of concentrations of the method was: 0.025–5000 mg l−1 for RP 57669, RP 54476 and RP 12536 and 0.010–0.750 mg l−1 for RP 69012 and RPR 100391.  相似文献   

13.
A sensitive and reliable high-performance liquid chromatographic (HPLC) assay is a prerequisite for pharmacokinetic analysis of continuous infusion of levomepromazine adjuvant to midazolam. We developed such a method to determine the levels of levomepromazine, midazolam and their major metabolites (levomepromazinesulfoxide, desmethyl-, didesmethyllevomepromazine, O-desmethyllevomepromazine and alpha-hydroxy-midazolam) simultaneously. Desmethylclomipramine was used as an internal standard (I.S.). The lower limit of quantification of this assay was set for levomepromazine 4.1 microg/l, levomepromazinesulfoxide 4.9 microg/l, O-desmethyllevomepromazine 18.4 microg/l, alpha-hydroxymidazolam 26.6 microg/l, midazolam 23.4 microg/l, didesmethyllevomepromazine 15.8 microg/l, and desmethyllevomepromazine 6.6 microg/l. The between- and within day assay variations were commonly below 5%. The recovery in human plasma for the different analytes varied between 85 and 11%. The accuracy of this assay varied between 95 and 105% for the different concentrations. The linearity of this assay was set between 25 and 800 microg/l (r(2)>0.999 of the regression line). The first results of pharmacokinetic analysis of midazolam indicated that half-life varied between 1.1 and 1.9 h. Pharmacokinetic analysis using a one-compartment model of levomepromazine revealed that the apparent volume of distribution was 4.1+/-2.4 l per kg lean body mass and the metabolic clearance was 309+/-225 l per hour per 70 kg. This assay proved to be robust and reproducible. It can reliably be used for further study of the pharmacokinetics of continuous infusion of levomepromazine.  相似文献   

14.
A high-performance liquid chromatographic method was developed for the specific determination of 2-n-propylquinoline, a new anti-leishmaniasis drug, in plasma and liver homogenates of mice. 2-n-Propylquinoline was extracted with methyl-tert.-butyl ether with quinoline as internal standard. Separation was carried out using a Nucleosil C18 column. The mobile phase consisted of methanol–0.005 M ammonium acetate buffer (60:40) at pH 5.5 and 8 for plasma and liver homogenates, respectively. Detection was monitored at 233 nm. The method was validated and shown to be accurate and precise for plasma and liver homogenates. Extraction yield was 96% in plasma and 81% in liver homogenates. This method was used to determine the pharmacokinetic profile of 2-n-propylquinoline following oral administration to mice.  相似文献   

15.
A HPLC method has been developed for the analogue of Ecstasy MDE and its major metabolites N-ethyl-4-hydroxy-3-methoxyamphetamine (HME) and 3,4-methylenedioxyamphetamine (MDA) in human plasma. In the course of our investigations we found that the methylenedioxyamphetamines and HME exhibit fluorescence at 322 nm. Therefore the detection could be carried out with a fluorescence (FL) detector. Solid-phase extraction was used for sample preparation and yielded high recovery rates greater than 95%. The limit of quantitation for MDE and its metabolites in the extracts was between 1.5 and 8.9 ng/ml and the method standard deviations were less than 5%. This sensitive, rapid and reliable analytical method has been used successfully in the quantitation of the substances in plasma samples obtained from 14 volunteers in two clinical studies after p.o. administration of 100 to 140 mg MDE*HCl. The maximum plasma concentrations were 235–465 ng/ml (MDE), 67–673 ng/ml (HME) and 7–33 ng/ml (MDA), respectively. Pharmacokinetic parameters have been investigated using the plasma concentration curves.  相似文献   

16.
A simple and rapid assay is described for the simultaneous analysis of levodopa (l-DOPA) and 3-O-methyldopa (3-OMD) in human plasma samples, applying an ion-pair reversed-phase liquid chromatographic method with electrochemical detection, designed for clinical trials performed to study the effect of peripheral catechol-O-methyltransferase inhibitors on the metabolism of l-DOPA. After protein precipitation of 100 microl plasma sample aliquots with perchloric acid, the analytes are directly injected, separated within 10 min and simultaneously quantified down to 20 ng/ml by an electrochemical detector equipped with a dual-electrode system operating in redox mode eliminating effectively potential endogenous and exogenous interferences. The intra-assay precision for l-DOPA and 3-OMD was 1.34-6.54 and 3.90-5.50%, whereas the inter-assay precision was 2.09-7.69 and 4.16-9.90%, respectively. The recoveries were close to 90% for l-DOPA and almost 100% for 3-OMD. Satisfactory storage stability was achieved for up to 16 weeks at -70 degrees C by stabilizing plasma samples with antioxidants.  相似文献   

17.
A high-performance liquid chromatographic method was developed for the simultaneous determination of phenylbutazone and its metabolites, oxyphenbutazone and γ-hydroxyphenylbutazone, in plasma and urine. Samples were acidified with hydrochloric acid and extracted with benzene—cyclohexane (1:1, v/v). The extract was redissolved in methanol and chromatographed on a μBondapak C15 column using a mobile phase of methanol—0.01 M sodium acetate buffer (pH 4.0) in a linear gradient (50 to 100% methanol at 5%/min; flow-rate 2.0 ml/min) in a high-performance liquid chromatograph equipped with an ultra-violet absorbance detector (254 nm). The detection limit for phenylbutazone, oxyphenbutazone and for γ-hydroxyphenylbutazone was 0.05 μg/ml.A precise and sensitive assay for the determination of phenylbutazone and its metabolites was established.  相似文献   

18.
The determination of quinine, (3S)-3-hydroxyquinine, 2′-quininone and (10R)- and (10S)-10,11-dihydroxydihydroquinine in plasma and urine samples is described. This is the first time the R and S configurations have been correctly assigned to the two metabolites of 10,11-dihydroxyquinine. One hundred microliter-plasma samples were protein precipitated with 200 μl cold methanol. Urine samples were 10–100× diluted and then directly injected into the HPLC. A reversed-phase liquid chromatography system with fluorescence detection and a Zorbax Eclipse XDB phenyl column and gradient elution was used. The within and between assay coefficients of variation of the method for quinine and its metabolites in plasma and urine was less than 13%. The lower limit of quantitation was in the range of 0.024–0.081 μM.  相似文献   

19.
A method for the simultaneous determination of the three selective serotonin reuptake inhibitors (SSRIs) citalopram, fluoxetine, paroxetine and their metabolites in whole blood and plasma was developed. Sample clean-up and separation were achieved using a solid-phase extraction method with C8 non-endcapped columns followed by reversed-phase high-performance liquid chromatography with fluorescence and ultraviolet detection. The robustness of the solid-phase extraction method was tested for citalopram, fluoxetine, paroxetine, Cl-citalopram and the internal standard, protriptyline, using a fractional factorial design with nine factors at two levels. The fractional factorial design showed two significant effects for paroxetine in whole blood. The robustness testing for citalopram, fluoxetine, Cl-citalopram and the internal standard revealed no significant main effects in whole blood and plasma. The optimization and the robustness of the high-performance liquid chromatographic separation were investigated with regard to pH and relative amount of acetonitrile in the mobile phase by a central composite design circumscribed. No alteration in the elution order and no significant change in resolution for a deviation of ±1% acetonitrile and ±0.3 pH units from the specified conditions were observed. The method was validated for the concentration range 0.050–5.0 μmol/l with fluorescence detection and 0.12–5.0 μmol/l with ultraviolet detection. The limits of quantitation were 0.025 μmol/l for citalopram and paroxetine, 0.050 μmol/l for desmethyl citalopram, di-desmethyl citalopram and citalopram-N-oxide, 0.12 μmol/l for the paroxetine metabolites by fluorescence detection, and 0.10 μmol/l for fluoxetine and norfluoxetine by ultraviolet detection. Relative standard deviations for the within-day and between-day precision were in the ranges 1.4–10.6% and 3.1–20.3%, respectively. Recoveries were in the 63–114% range for citalopram, fluoxetine and paroxetine, and in the 38–95% range for the metabolites. The method has been used for the analysis of whole blood and plasma samples from SSRI-exposed patients and forensic cases.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号