1.
A high-performance liquid chromatography (HPLC) method with UV detection was developed for the simultaneous determination of arsanilic acid, roxarsone, nitarsone, and carbarsone in the feeds of swine and chicken. Feed samples were extracted with methanol/1% acetic acid (90:10, v/v) in an ultrasonic bath and the protein was precipitated with 2% Cu(2)SO(4). The samples were further purified by solid phase extraction (SPE) on SAX cartridges. Separation was performed on a Zorbax SB-Aq C18 HPLC column using an isocratic procedure with methanol and 1% acetic acid (3:97, v/v) at a flow-rate of 0.7 mL min(-1), and the UV detector was set at a wavelength of 260 nm. The recoveries of organoarsenic compounds spiked at levels of 2, 20 and 200 μg g(-1) ranged from 81.2% to 91.3%; the inter-day relative standard deviation values were less than 7.0%. The limits of quantification for four organoarsenic compounds were 1.0-2.0 μg g(-1). This simple and fast method could be applied to the determination of multi-residues of organic arsenic compounds in animal feeds.  相似文献   

2.
A high-performance liquid chromatographic method has been developed and tested for simultaneous extraction, elution and determination of doxorubicin and prochlorperazine content in human plasma samples. The procedure consists of extraction through a conditioned C18 solid-phase extraction cartridge, elution from a Spherisorb C8 reversed-phase column by an isocratic mobile phase (60% acetonitrile, 15% methanol and 25% buffer) followed by detection with electrochemical and fluorescence detectors. Recovery of doxorubicin and prochlorperazine from pooled human plasma samples (n=3) containing 100 ng/ml of the two drugs was 77.8±3.5% and 89.1±6.0%, respectively. The lower limits of quantitation for doxorubicin and prochlorperazine in plasma samples were 6.25 ng/ml and 10 ng/ml, respectively. A linear calibration curve was obtained for up to 2 μg/ml of doxorubicin and prochlorperazine. This combination method may be of particular value in clinical studies where phenothiazines such as prochlorperazine are used to enhance retention of doxorubicin in drug resistant tumor cells.  相似文献   

3.
A sensitive and rapid high-performance liquid chromatographic screening method is described for the determination of anabolic steroid trenbolone in bovine muscle and liver. Trenbolone was analyzed as α- and β-trenbolone. Samples were extracted with ethyl acetate and cleaned up on a silica solid-phase extraction (SPE) cartridge. Liver samples were cleaned up on a multifunctional SPE cartridge before using a silica SPE cartridge. Analysis of α- and β-trenbolone was performed by reversed-phase high-performance liquid chromatography (HPLC) with a fluorescence detector. The detection limits for this method were estimated to be 0.2 and 1.0 ng/g in bovine muscle and liver, respectively. The mean recoveries spiked in muscle at 2 ng/g and in liver at 10 ng/g were over 80%.  相似文献   

4.
Mianserin is a tetracyclic antidepressant drug and administered as racemate of R (-) and S (+) mianserin hydrochloride in a dose of 30-90 mg/day in divided doses. Liquid chromatography-mass spectroscopy (LC-MS) is a tool, which is widely used for determination of drug and their metabolites in biological fluids because of its high sensitivity and precision. Here we describe a liquid chromatography mass spectroscopy method for simultaneous determination of mianserin and its metabolite, N-desmethylmianserin, from human plasma using a liquid-liquid extraction with hexane:isoamylalcohol (98:2) and back extraction with 0.005 M formic acid solution. This method is specific and linear over the concentration range of 1.00-60.00 ng/ml for mianserin and 0.50-14.00 ng/ml for N-desmethylmianserin in human plasma. The lowest limits of quantification (LLQ) is 1.00 ng/ml for mianserin and 0.50 ng/ml for N-desmethylmianserin. Intraday and interday precision (%C.V.) is <10% for both mianserin and N-desmethylmianserin. The accuracy ranges from 94.44 to 112.33% for mianserin and 91.85-100.13% for N-desmethylmianserin. The stability studies showed that mianserin and N-desmethylmianserin in human plasma are stable during short-term period for sample preparation and analysis. The method was used to assay mianserin and its metabolite, N-desmethylmianserin, in human plasma samples obtained from subjects who had been given an oral tablet of 30 mg of mianserin.  相似文献   

5.
Two new stable isotope dilution assays were developed for the quantification of ochratoxin A in human blood samples for exposure studies. The methods based on two different sample extraction and cleanup procedures including liquid–liquid extraction with following immunoaffinity chromatography (IA) as well as a dispersive solid-phase extraction (DSPE) method. For detection, LC–MS/MS was applied. For the first time, exact quantitation of the reference compound ochratoxin A was performed by quantitative NMR spectroscopy (qNMR). Additionally, a comparison of different blood-drawing procedures revealed no differences for heparin plasma and serum whereas citrate plasma gave significantly lower results for the mycotoxin. Limits of detection (LOD: 0.02 ng/g (IA) vs 0.03 ng/g (DSPE)), limits of quantification (LOQ: 0.07 ng/g (IA) vs 0.08 ng/g (DSPE)), relative recovery (?94%), precision, and linearity indicated excellent performance of the developed methods.  相似文献   

6.
A comprehensive method was developed for the simultaneous analysis in human breast milk of 12 synthetic musks, five nitro musks, six polycyclic muks and one macrocyclic musk; as well as one musk metabolite and triclosan. The target analytes were freeze dried and extracted using the accelerated solvent extraction (ASE) procedure. The extracts were further purified by gel permeation chromatography (GPC) and florisil solid-phase extraction (SPE) and then analyzed by gas chromatography tandem mass spectrometry (GC-MS/MS). Recoveries of the analytes based on the isotopic internal standard correction ranged from 82.4% to 112%, with relative standard derivations less than 20%. The method quantification limits (MQLs) were 0.6-5.4 ng/g lipid. The analytes were detected in human breast milk samples and ranged from 11.7 to 308.6 ng/g lipid.  相似文献   

7.
A liquid chromatography-ion trap mass spectrometry method with three "time segments" has been developed to determine malachite green (MG) and its major metabolite, leucomalachite green (LMG) in edible goldfish muscle. By using the optimized "time segments", MG and LMG as well as the internal standard atrazine-d(5) were analyzed with good sensitivity with positive ESI-MS in a single run. The homogenized fish muscle tissues were extracted with a solution of perchloric acid and acetonitrile, followed by partitioning with dichloromethane. Strata-x polymeric solid-phase extraction column was used for the clean-up process. The determination of MG and LMG was achieved by using a reversed-phase HPLC gradient program coupled with MS/MS in multiple-reaction-monitoring mode. Matrix calibration curves were linear over the ranges of 5-500 ng/ml for MG and 1-100 ng/ml for LMG. Recoveries of the fish tissue extraction at three spiked levels (2, 10 and 30 ng/g for MG as well as 0.4, 2 and 6 ng/g for LMG) were better than 71% and 89%, respectively. Relative standard derivations from six determinations were less than 8%. The method detection limits were 0.13 ng/g for MG and 0.06 ng/g for LMG.  相似文献   

8.
A reversed-phased liquid chromatography with tandem mass spectrometry (LC-MS/MS) method was developed and validated for quantitation of the total and unbound RO4929097, a γ-secretase inhibitor targeting Notch signaling, in human plasma. Sample preparation involved a liquid-liquid extraction with ethyl acetate. Chromatographic separation was achieved on a Waters X-Terra? MS C(18) column with an isocratic mobile phase consisting of methanol/0.45% formic acid in water (60:40, v/v) running at a flow rate of 0.2 ml/min for 6 min. The lower limits of quantitation (LLOQs) were 5 ng/ml for the total RO4929097 in plasma and 0.5 ng/ml for the unbound drug in phosphate buffer solution (PBS). Calibration curves were linear over RO4929097 concentration range of 5-2000 ng/ml in plasma for the total drug and 0.5-200 ng/ml in PBS for the unbound drug. The intra-day and inter-day accuracy and precision were within the generally accepted criteria for bioanalytical method (<15%). The method has been successfully employed to characterize the total and unbound plasma pharmacokinetics of RO4929097 after its oral administration in cancer patients.  相似文献   

9.
A sensitive liquid chromatography-mass spectrometric (LC-MS) method for quantification of an active psychedelic hallucinogenic drugs (trimethoxyamphetamines) in human urine after solid-phase extraction (SPE) with C(18) cartridge was developed and validated. Chromatographic separation was achieved on reversed-phase Phenomenex 3.0 microm Polar Plus column (150 mm x 2.1 mm) with acetonitrile -0.2% acetic acid as mobile-phase and the step gradient elution resulted in a total run time of about 20 min. The analytes were detected by using an electrospray positive ionization mass spectrometry in selected ion monitoring (SIM) mode. In the evaluated concentration range (10-200 ng/mL) (R(2) > or = 0.998) a good linear relationship was obtained. The lower limits of detection (LLODs) and quantification (LLOQs) ranged from 4.26 to 9.12 ng/mL and from 13.18 to 29.22 ng/mL, respectively. Average recoveries ranged from 68.52 to 97.90% in urine at the concentrations of 25, 50 and 100 ng/mL. Intra- and inter-day relative standard deviations were 3.70-10.77% and 7.63-12.94%, respectively. This LC-MS method proved to be robust and reliable, and suitable for the use as a confirmation method in clinical urine drug testing.  相似文献   

10.
A rapid, sensitive and selective method has been developed for the quantification of plasma concentrations of neuromuscular blocking drug, rocuronium, using gas chromatography with mass spectrometric detection. 3-Desacetylvecuronium served as the internal standard. The method involved iodide ion pair formation and a single-step liquid–liquid extraction with dicholoromethane. This method also permits simultaneous determination of its putative metabolite, 17-desacetylrocuronium, although the high detection limit for the metabolite limits the practical application of this method in pharmacokinetic study of the metabolite. The extraction efficiency was 75% for rocuronium and 50% for 17-desacetylrocuronium. The limit of quantification was 26 ng/ml for rocuronium and 870 ng/ml for its metabolite. The assay was used successfully in a patient undergoing liver transplantation and receiving rocuronium as a constant rate infusion and in a patient undergoing general elective surgery receiving the drug as an intravenous bolus. This assay is a time-saving alternative to published gas or liquid chromatographic methods for assaying rocuronium.  相似文献   

11.
A capillary electrophoresis (CE) method for the quantification of R-(−)- and S-(+)-prilocaine in human serum was developed and validated. Stereoselective resolution was accomplished using 15 mM heptakis(2,6-di-methyl)-β-cyclodextrin and 0.03 mM hexadecyltrimethylammonium bromide (HTAB) contained in 100 mM phosphate buffer, pH 2.5. Solid-phase extraction was used as a sample preparation technique to remove endogenous interferences. A 72-cm uncoated fused-silica capillary at a voltage of 25 kV and 30°C was used for the analysis. The detection limits for R-(−)- and S-(+)-prilocaine were 38 ng/ml using 1 ml of human serum and the limits of quantitation were 45 ng/ml. The calibration curve was linear over the range of 45–750 ng/ml with procainamide as the internal standard. Precision and accuracy of the method were 2.86–8.50% and 3.29–7.40%, respectively, for R-(−)-prilocaine, and 3.94–9.17% and 2.0–6.73%, respectively, for S-(+)-prilocaine. The CE method was compared to an existing chiral HPLC method in terms of sensitivity and selectivity for the routine analysis of the drug.  相似文献   

12.
A sensitive high-performance liquid chromatographic (HPLC) method for the determination of metronidazole in vaginal tissue is reported. The method uses a Zorbax SB phenyl column with a 0.01 M aqueous monobasic potassium phosphate buffer (pH 4.0)-absolute methanol (85:15, v/v) as mobile phase at a flow-rate of 1.0 ml/min and detection at 313 nm. Tinidazole was used as the internal standard. The method employed homogenization of tissue followed by solid-phase extraction. The quantitation was achieved within 30 min with sensitivity in the ng/g range. Metronidazole was linear in the 100–2000 ng/g range. The accuracy and precision were in the 1–4% range for the drug and the limit of detection was approximately 100 ng/g based on a signal-to-noise ratio of 3 and a 100-μl injection.  相似文献   

13.
A routine method for the determination of a novel class III antidysrhythmic agent, 1-(4-methane-sulphonamidophenoxy)-2-[N-(4-methanesulponamidophenethyl)-N-methylamino]ethane, in human urine has been developed. The method involves solvent extraction followed by high-performance liquid chromatography on an unmodified silica column with ultraviolet detection. Despite a low recovery of drug through the three-stage extraction procedure a reliable assay with high precision (coefficient of variation less than 6%) and a limit of determination of 2.5 ng/ml was achieved. The method has been applied to the analysis of samples following single oral and intravenous doses of 1–12.5 μg/kg of the drug to human volunteers.  相似文献   

14.
The purpose of this study was to develop an optimized method for the extraction and determination of 17α-ethinylestradiol (EE2) and estrone (E1) in whole fish tissues at ng/g levels. The optimized procedure for sample preparation includes extraction of tissue by accelerated solvent extraction (ASE-200), lipid removal by gel permeation chromatography (GPC), and a cleanup step by acetonitrile precipitation followed by a hexane wash. Analysis was performed by gas chromatography/mass spectrometry (GC/MS) in negative chemical ionization (NCI) mode after samples were derivatized with pentafluorobenzoyl chloride (PFBCl). The method was developed using high lipid content wild fish that were exposed to the tested analytes. The whole procedure recoveries ranged from 74.5 to 93.7% with relative standard deviation (RSD) of 2.3-6.2% for EE2 and 64.8 to 91.6% with RSD of 9.46-0.18% for E1. The method detection limits were 0.67 ng/g for EE2 and 0.68 ng/g for E1 dry weight. The method was applied to determine EE2 levels in male goldfish (Carrasius auratus) after a 72 h dietary exposure. All samples contained EE2 averaging 1.7ng/g (±0.29 standard deviation, n=5). This is the first optimized protocol for EE2 extraction from whole fish tissue at environmentally relevant concentrations. Due to high sensitivity and recovery, the developed method will improve our knowledge about the environmental fate and uptake of synthetic steroidal estrogens in fish populations.  相似文献   

15.
A new and efficient procedure for the clean-up of tetracycline residues in animal tissues and egg prior to reversed-phase high-performance liquid chromatography is described. The principal steps involve homogenization of the tissues in sodium succinate buffer and methanol, followed by centrifugation and clean-up with metal chelate affinity chromatography (MCAC). After further concentration on an Empore extraction membrane with cation-exchange properties, the sample is analysed by HPLC with fluorescence detection. The method was tested on porcine kidney and muscle, bovine liver and whole chicken's egg. The recoveries were determined from spiked tissues for oxytetracycline, tetracycline, chlortetracycline and doxycycline and ranged from 40 to 70%, with repeatabilities below 10% R.S.D.. The analytical responses were linear in the range up to at least 1000 ng/g. The detection limits of the method were estimated at 0.42 ng/g of oxytetracycline, 0.49 ng/g of tetracycline, 0.66 ng/g of chlortetracycline and 1.38 ng/g of doxycycline in porcine muscle, using signal-to-noise ratios of 4:1. Similar detection limits were estimated for kidney, liver and egg. The measured limits of quantification were 2 ng/g for oxytetracycline, 3 ng/g for tetracycline, 4 ng/g for chlortetracycline and 5 ng/g for doxycycline in porcine kidney. The advantage of this method over existing methods is its increased limit of detection.  相似文献   

16.
Twelve compounds representing procarbazine, seven metabolites, and an internal standard were analyzed by gas chromatography—mass spectrometry on a 3% OV-1 column. Procarbazine and four metabolites were derivatized with acetic anhydride.A sensitive, specific and quantitative assay was established by selected ion monitoring using a synthetic analogue of the drug as an internal standard. The limits of detection were approximately 1 ng/ml of plasma while the limits of quantitation were 10 ng/ml of plasma.Studies on the degradation of procarbazine - HCl in 0.05 M phosphate buffer (pH 7.4) were compared to in vivo studies. At 1 h after incubation of procarbazine - HCl in buffer, the azo and aldehyde metabolites were detected in the highest concentrations representing 27.2% and 20.3% of total drug and metabolites. In the in vivo studies, analyses of rat plasmas indicated that 1 h after an oral dose of procarbazine - HCl, the aldehyde metabolite represented 72% of the total drug and metabolites, and that relatively little of the azo metabolite was present.  相似文献   

17.
A sensitive and simple HPLC method was developed for the determination of a novel compound, a potential anti-cancer drug, N-(2-hydroxy-5-nitrophenylcarbamothioyl)-3,5-dimethylbenzamide (DM-PIT-1), a member of the new structural class of non-phosphoinositide small molecule antagonist of phosphatidylinositol-3,4,5-trisphosphate-pleckstrin-homology domain interactions, in mouse plasma and tumor tissue homogenates. The chromatographic separation of DM-PIT-1 was achieved on C18 column using isocratic elution with acetonitrile-water (70:30) containing 0.1% formic acid (v/v). DM-PIT-1 was detected by UV absorbance at 320 nm and confirmed by LC-MS. The extraction of the DM-PIT-1 from the plasma and tumor tissue with methylene chloride resulted in its high recovery (70-80%). HPLC calibration curves for DM-PIT-1 based on the extracts from the mouse plasma and tumor tissue samples were linear over a broad concentration range of 0.25-20 μg/ml/g, with intra/inter-day accuracy of 95% and the precision of variation below 10%. The limits of detection and quantification were 0.1 ng and 0.2 ng, respectively. The described method was successfully applied to study the pharmacokinetics of the DM-PIT-1 following the parenteral injections of DM-PIT-1 entrapped in 1,2-disteratoyl-sn-glycero-3-phosphoethanolamine-N-[methoxy(polyethylene-glycol)-2000] (PEG-PE) micelles.  相似文献   

18.
This study examines a novel sample preparation method for the determination of 11 hydroxy metabolites of polychlorinated biphenyls (PCBs) in plasma and organ tissues, followed by gas chromatography with mass spectrometric detection (GC/MS). The clean-up method was optimized to eliminate the interference matter by using a silica column and 10 mL of n-hexane/dichloromethane (4:6, v/v) as an eluent. Solid-phase and solvent extraction procedures were used for the plasma and tissues samples, respectively. Compared to C(18) and C(8) solid-phase, C(2) showed higher extraction efficiency with n-hexane as the eluent for plasma. The hydroxy-PCB extraction recoveries achieved with this combined extraction and clean-up procedure from plasma ranged from 87 to 117%, while those from tissues ranged from 82 to 111%. The linear detector responses for propyl derivatives of hydroxy-PCBs were obtained with the coefficients of determination varying from 0.992 to 0.998 in the concentration range of 0.1-20 ng mL(-1). The method detection limits ranged from 0.1 to 0.5 ng mL(-1) in 1 mL of plasma and from 0.1 to 0.5 ng g(-1) in 1g of tissues. This procedure was successfully applied to the study of 3-OH-2,3',4,4',5-PeCB in rat plasma and liver samples after intraperitoneal injection (20 mg/kg) of 2,3',4,4',5-PeCB.  相似文献   

19.
三聚氰胺胶体金免疫层析试纸条的研制   总被引:3,自引:0,他引:3  
通过胶体金免疫层析技术建立一种特异、便捷、快速的三聚氰胺抗原检测方法,对奶制品及饲料中的三聚氰胺残留水平监测提供参考。用柠檬酸三钠还原法制备的胶体金,标记纯化的三聚氰胺单克隆抗体,喷于试纸的金标垫。将MEL-OVA(三聚氰胺和卵清白蛋白的偶练物)和纯化的羊抗鼠IgG分别喷于试纸的T(检测线)处和C(质控线)处,通过挑选试纸条材料和调试工艺参数,并最终组装成试纸条。结果显示,制备的试纸监测体系方法检出限为50 g/L。试纸条对牛奶、奶粉和饲料中的三聚氰胺残留的检出限分别为100 g/L、100 ng/g和200 ng/g。将该法与LC-MS/MS法对比检测牛奶、奶粉和饲料样品,在试纸条检测范围内,与LC-MS/MS法检测结果一致性好,从而验证了该方法的有效性。制备的三聚氰胺胶体金检测试纸在常温干燥环境下至少可保质6个月,能够检测出三聚氰胺含量大于50 g/L的样品,适用于现场实际样品三聚氰胺残留水平监测,具有良好的应用前景。  相似文献   

20.
An assay comprising two simple, selective and isocratic HPLC methods with UV detection was developed and validated for measuring warfarin enantiomers and all five warfarin monohydroxylated metabolites in patient blood plasma. Following liquid/liquid extraction from 1 ml of blood plasma a baseline separation of analytes was achieved on chiral (alpha(1) acid glycoprotein - AGP) and achiral (C(18)) column. Both methods were consistent (R.S.D.<6.9% for warfarin enantiomers and<8.9% for monohydroxylated metabolites) and linear (r>0.998). The limits of detection were 25 ng/ml for warfarin enantiomers, 25 ng/ml for 4'-, 10-, 6- and 7-hydroxywarfarin, 35 ng/ml for 8-hydroxywarfarin and 50 ng/ml for racemic warfarin. In a clinical study in 204 patients, it was confirmed that the assay is appropriate for evaluation of influences of genetic polymorphisms, demographic factors and concomitant drug treatment on warfarin metabolism.  相似文献   