首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A rapid and sensitive method using liquid chromatography-tandem mass spectroscopy (LC-MS/MS) was developed and validated for simultaneous quantitative determination of valproic acid and three major metabolites (3-OH-valproic acid, 4-ene-valproic acid and 5-OH-valproic acid) in human plasma. The analytes and internal standard were isolated from 200 μL samples by solid phase extraction using a ZORBAX SB-C? column (3.5 μm, 2.1×100 mm) with an isocratic mobile phase consisting of methanol-10mM ammonium acetate (80:20, v/v) containing 0.1% formic acid at a flow rate of 0.3 mL/min. The method had a chromatographic total run time of 2.0 min. The lower limit of quantification of valproic acid, 3-OH-valproic acid, 4-ene-valproic acid and 5-OH-valproic acid of the method was 2030, 51.5, 50.15 and 51.25 ng/mL, respectively. The method was linear for valproic acid and the three metabolites with correlation coefficients >0.995 for all analytes. The intra-day and inter-day accuracy and precision of the assay were less than 15.0%. This analytical method was successfully used to assay plasma concentrations of valproic acid and the three metabolites in human plasma from epileptic patients.  相似文献   

2.
A rapid and sensitive liquid chromatography/tandem mass spectrometry (LC-MS/MS) method has been developed and fully validated to determine HS270, a new histone deacetylase (HDAC) inhibitor, in rat plasma using SAHA as the internal standard (IS). After a single step liquid-liquid extraction with acetoacetate, analytes were subjected to LC-MS/MS analysis using positive electro-spray ionization (ESI(+)) under selected reaction monitoring mode (SRM). The chromatographic separation was achieved on a Hypurity C(18) column (50 mm × 2.1 mm, i.d., 5 μm). The MS/MS detection was conducted by monitoring the fragmentation of m/z 392.3→100.1 for HS270, m/z 265.1→232.1 for IS. The method had a chromatographic running time of 2.5 min and linear calibration curves over the concentrations of 0.5-1000 ng/mL. The recovery of the method was 70.8-82.5% and the lower limit of quanti?cation (LLOQ) was 0.5 ng/mL. The intra- and inter-batch precisions were less than 15% for all quality control samples at concentrations of 1.0, 100.0, and 750.0 ng/mL. The validated LC-MS/MS method has successfully applied to a HS270 pharmacokinetic study after oral doses of 25, 50, 100, 200 mg/kg, and i.v. dose of 5 mg/kg to rats.  相似文献   

3.
A sensitive and rapid LC-MS/MS method was developed and validated for the determination of levamisole in human plasma. The assay was based on liquid-liquid extraction of analytes from human plasma with ethyl ether. Chromatographic separation was carried on an Agilent HC-C(8) column (150 mm × 4.6 mm, 5 μm) at 40°C, with a mobile phase consisting of acetonitrile-10 mM ammonium acetate (70:30, v/v), a flow rate of 0.5 mL/min and a total run time of 6 min. Detection and quantification were performed by mass spectrometry in the multiple reaction monitoring mode with positive electrospray ionization m/z at 205.1→178.2 for levamisole, and m/z 296.1→264.1 for mebendazole (internal standard). The assay was linear over a concentration range of 0.1-30 ng/mL with a lower limit of quantification of 0.1 ng/mL. The coefficient of variation of the assay precision was less than 8.5%. The assay was successfully used to analyze human plasma samples in a pharmacokinetic study where levamisole was administered as a liniment.  相似文献   

4.
The alkaloids from Piper longum L. showed protective effects on Parkinson's disease models in our previous study and piperine and piperlonguminine were the two main constituents in the alkaloids. The present study aimed at developing a rapid, sensitive, and accurate UFLC-ESI-MS/MS method and validating it for the simultaneous determination of piperine and piperlonguminine in rat plasma using terfenadine as the internal standard. The analytes and internal standard (IS) were extracted from rat plasma using a simple protein precipitation by adding methanol/acetonitrile (1:1, v/v). A Phenomenex Gemini 3 u C18 column (20 mm × 2.00 mm, 3 μm) was used to separate the analytes and IS using a gradient mode system with a mobile phase consisting of water with 0.1% formic acid (mobile phase A) and acetonitrile with 0.1% formic acid (mobile phase B) at a flow rate of 0.4 mL/min and an operating column temperature of 25°C. The total analytical run time was 4 min. The detection was performed using the positive ion electrospray ionization (ESI) in multiple reaction monitoring (MRM) mode with transitions at m/z 286.1-201.1 for piperine, m/z 274.0-201.1 for piperlonguminine, and m/z 472.4-436.4 for the IS. The calibration curves were both linear (r>0.995) over a concentration range of 1.0 to 1000 ng/mL; the lower limit of quantification (LLOQ) was 1.0 ng/mL for both piperine and piperlonguminine. The intra-day and inter-day precisions (RSD %) were <12.1%, accuracies ranged from 86.6 to 120%, and recoveries ranged from 90.4 to 108%. The analytes were proven stable in the short-term, long-term, and after three freeze-thaw cycles. The method was successfully applied to pharmacokinetic studies of piperine and piperlonguminine in rats after oral administration of alkaloids from P. longum L.  相似文献   

5.
A novel isocratic reversed-phase high performance liquid-chromatography/ultraviolet detection method for simultaneous determination of cefdinir and cefixime in human plasma was developed and validated after optimization of various chromatographic conditions and other experimental parameters. Sample preparation based on a simple extraction procedure consisting of deproteination and extraction with 3 parts of 6% trichloroacetic acid aqueous solution followed by volume make up with the aqueous component of the mobile phase obtained best recoveries of the two analytes. Samples were separated on a Supelco Discovery HS C(18) (150 mm × 4.6 mm, 5 μm) analytical column protected by a Perkin Elmer C(18) (30 mm × 4.6 mm, 10 μm) guard cartridge. The mobile phase, methanol/acetonitrile (50/50, v/v):0.05% trifluoroacetic acid (19:81, v/v), operated at 50°C column oven temperature was pumped at a flow rate of 2.0 mL min(-1) and the column eluents were monitored at a wavelength of 285 nm. When Sample was injected into the Perkin Elmer high performance liquid-chromatography system through Rheodyne manual (or auto-sampler) injector equipped with 20 μL loop, separation was achieved within 4 min. The present method demonstrated acceptable values for selectivity, linearity within the expected concentration range (0.004-5.0 μg mL(-1); r(2)>0.999 for both analytes), recovery (>95% for cefdinir and >96% for cefixime), precision (%RSD<2.0 for cefdinir and <2.2 for cefixime), sensitivity (limit of detection: 1 ng mL(-1) and lower limit of quantification: 4 ng mL(-1) for both analytes), stability of solutions, and robustness. The method was efficiently applied to a pharmacokinetic study in healthy volunteers.  相似文献   

6.
Felbamate (2-phenyl-1,3-propanediol dicarbamate) is a second generation antiepileptic drug used to treat seizures refractory to other antiepileptic drugs. With approximately 3500 new patients exposed annually, several important pharmacologic interaction questions remain unanswered necessitating the need for rapid and accurate methods of felbamate analysis in biological matrices. To this end, a rapid liquid chromatography tandem mass spectrometry (LC-MS/MS) method was developed for the measurement of felbamate in mouse plasma and tissues and human plasma. Plasma (100 μL) and tissues homogenates (100 μL of 100 mg/mL) were spiked with internal standard (carisoprodol) prior to protein precipitation with acetonitrile. Samples were chromatographed on a XBridge Phenyl, 2.5 μm, 4.6 mm×50 mm column with quantitation by internal standard reference monitoring of the ion transitions m/z 239→117 for felbamate and m/z 261→176 for carisoprodol. Calibration curves were linear from 2.5 to 500 ng/mL in mouse or human plasma and 25-5000 pg/mg in tissue homogenates. Recoveries were greater than 97% for plasma and homogenates with accuracies >92% in any of the mouse matrices and >88% in human plasma. Comparable accuracies and precision were found with and without the use of the internal standard in preparation of the calibration curves and suggest that the internal standard may not be required.  相似文献   

7.
A sensitive and reliable ultra-high-performance liquid chromatography-electrospray ionization-tandem mass spectrometry (UHPLC-ESI-MS/MS) has been developed and validated for the simultaneous determination of three active components, i.e., tectorigenin, irigenin and irisflorentin, in rat plasma and urine after oral administration of Rhizoma Belamcandae extract. Chromatographic separation was achieved on a Zorbax SB-C(18) column (50 mm × 2.1 mm, 1.8 μm; Agilent, USA) with gradient elution using a mobile phase that consisted of acetonitrile - 0.1% formic acid in water at a flow rate of 0.4 mL/min. Detection was performed by a triple-quadrupole tandem mass spectrometer in multiple reaction monitoring (MRM) mode via polarity switching between the negative (for tectorigenin and irigenin) and positive (for irisflorentin) ionization modes. The calibration curve was linear over a range of 50-50,000 ng/mL for tectorigenin, 10-5000 ng/mL for irigenin and 0.1-200 ng/mL for irisflorentin, respectively. The intra- and inter-day precisions (RSD %) were within 11.3% for all analytes, whereas the deviation of assay accuracies ranged from -8.7 to +11.1%. All analytes were proven to be stable during all sample storage and analysis procedures. This method was successfully applied to a pharmacokinetic study of the three isoflavones after oral administration of Rhizoma Belamcandae extract to rats.  相似文献   

8.
Determination of eprosartan in human plasma and urine by LC/MS/MS   总被引:1,自引:0,他引:1  
A protein precipitation, liquid chromatography/tandem mass spectrometry (LC/MS/MS) method has been developed and validated for the determination of eprosartan in human plasma and urine. The solvent system also served as a protein precipitation reagent. The chromatographic separation was achieved on a CAPCELL PAK C18 column (50 mmx2.0 mm, 5 microm, Shiseido). A mobile phase was consisted of 0.5% formic acid in water and 0.5% formic acid in acetonitrile (72:28). Detection was by positive ion electrospray tandem mass spectrometry on a Sciex API3000. The standard curves, which ranged from 5 to 2000 ng/mL in human plasma and from 0.25 to 50 microg/mL in urine, were fitted to a 1/x weighted quadratic regression model. The method proved to be accurate, specific and sensitive enough to be successfully applied to a pharmacokinetic study.  相似文献   

9.
A 96-well single-pot protein precipitation, liquid chromatography/tandem mass spectrometry (LC/MS/MS) method has been developed and validated for the determination of muraglitazar, a PPAR alpha/gamma dual agonist, in human plasma. The internal standard, a chemical analogue, was dissolved in acetonitrile containing 0.1% formic acid. The solvent system was also served as a protein precipitation reagent. Human plasma samples (0.1 mL) and the internal standard solution (0.3 mL) were added to a 96-well plate. The plate was vortexed for 1 min and centrifuged for 5 min. Then the supernatant layers were directly injected into the LC/MS/MS system. The chromatographic separation was achieved isocratically on a Phenomenox C18(2) Luna column (2 mm x 50 mm, 5 microm). The mobile phase contained 20/80 (v/v) of water and acetonitrile containing 0.1% formic acid. Detection was by positive ion electrospray tandem mass spectrometry on a Sciex API 3000. The standard curve, which ranged from 1 to 1000 ng/mL, was fitted to a 1/x weighted quadratic regression model. This single-pot approach effectively eliminated three time consuming sample preparation steps: sample transfer, dry-down, and reconstitution before the injection, while it preserved all the benefits of the traditional protein precipitation. By properly adjusting the autosampler needle offset level, only the supernatant was injected, without disturbing the precipitated proteins in the bottom. As a result, the quality of chromatography and column life were not compromised. After more than 600 injections, there was only slightly increase of column back-pressure. The validation results demonstrated that this method was rugged and provide satisfactory precision and accuracy. The method has been successfully applied to analyze human plasma samples in support of a first-in-man study. This method has also been validated in monkey and mouse plasma for the determination of muraglitazar.  相似文献   

10.
A new LC-ESI-MS/MS assay method has been developed and validated for the quantification of swertiamarin, a representative bioactive substance of Swertia plants, in rat plasma using gentiopicroside, an analog of swertiamarin on chemical structure and chromatographic action, as the internal standard (IS). The swertiamarin and IS were extracted from rat plasma using solid-phase extraction (SPE) as the sample clean-up procedure, and they were chromatographed on a narrow internal diameter column (Agilent ZORBAX ECLIPSE XDB-C(18) 100 mm × 2.1 mm, 1.8 μm) with the mobile phase consisting of methanol and water containing 0.1% acetic acid (25:75, v/v) at a flow rate of 0.2 mL/min. The detection was performed on an Agilent G6410B tandem mass spectrometer by negative ion electrospray ionisation in multiple-reaction monitoring mode while monitoring the transitions of m/z 433 [M+CH(3)COO](-)→179 and m/z 415 [M+CH(3)COO](-)→179 for swertiamarin and IS, respectively. The lower limit of quantification (LLOQ) was 5 ng/mL within a linear range of 5-1000 ng/mL (n=7, r(2)≥0.994), and the limit of detection (LOD) was demonstrated as 1.25 ng/mL (S/N≥3). The method also afforded satisfactory results in terms of sensitivity, specificity, precision (intra- and inter-day), accuracy, recovery, freeze/thaw, long-time stability and dilution integrity. This method was successfully applied to determination of the pharmacokinetic properties of swertiamarin in rats after oral administration at a dose of 20 mg/kg. The following pharmacokinetic parameters were obtained (mean): maximum plasma concentration, 1920.1 ng/mL; time to reach maximum plasma concentration, 0.945 h; elimination half-time, 1.10h; apparent total clearance, 5.638 L/h/kg; and apparent volume of distribution, 9.637 L/kg.  相似文献   

11.
The main purpose of this study was to develop and validate a rapid, specific, sensitive, and reliable LC-MS/MS-based bioanalytical method for the determination of carboplatin in human plasma. The optimal chromatographic behavior of carboplatin was achieved on a Biobasic SCX column (50 mm × 2.1 mm, 5 μm) using ion exchange chromatography. The total LC analysis time per injection was 2.6 min with a flow rate of 1.5 mL/min with a gradient elution. Optimization with regard to improving recovery and minimizing matrix effects using HybridSPE-precipitation (HybridSPE-PPT) has been evaluated under various extraction conditions. As a result, sample preparation via HybridSPE-PPT with 1% formic acid in acetonitrile in a 96-well format was applied for method validation and sample analysis and showed acceptable recovery of greater than 25% and negligible matrix effects. The method validation was conducted over the curve range of 2.00-2000 ng/mL using 0.0500 mL of plasma sample. The intra- and inter-day precision and accuracy of the quality control samples at low, medium, and high concentration levels showed ≤4.8% relative standard deviation (RSD) and -13.2 to -3.6% relative errors (RE). The method was successfully applied to determine carboplatin in human plasma samples.  相似文献   

12.
A sensitive, selective and rapid liquid chromatographic/electrospray ionization tandem mass spectrometric assay was developed and validated for the simultaneous quantification of 16-dehydropregnenolone (DHP) and its five metabolites 4,16-pregnadien-3, 20-dione (M(1)), 5-pregnene-3beta-ol-20-one (M(2)), 5-pregnene-3beta, 20-diol (M(3)), 5-pregnene-3beta-ol-16, 17-epoxi-20-one (M(4)) and 5,16-pregnadien-3beta, 11-diol-20-one (M(5)) in rabbit plasma using dexamethasone as internal standard (IS). The analytes were chromatographed on Spheri-5 RP-18 column (5 microm, 100 mm x 4.6 mm i.d.) coupled with guard column using acetonitrile:ammonium acetate buffer (90:10, v/v) as mobile phase at a flow rate of 0.65 ml/min. The quantitation of the analytes was carried out using API 4000 LC-MS-MS system in the multiple reaction monitoring (MRM) mode. The method was validated in terms of linearity, specificity, sensitivity, recovery, accuracy, precision (intra- and inter-assay variation), freeze-thaw, long-term, auto injector and dry residue stability. Linearity in plasma was observed over a concentration range of 1.56-400 ng/ml with a limit of detection (LOD) of 0.78 ng/ml for all analytes except M(3) and M(5) where linearity was over the 3.13-400 ng/ml with LOD of 1.56 ng/ml. The absolute recoveries from plasma were consistent and reproducible over the linearity range for all analytes. The intra- and inter-day accuracy and precision method were within the acceptable limits and the analytes were stable after three freeze-thaw cycles and their dry residues were stable at -60 degrees C for 15 days. The method was successfully applied to determine concentrations of DHP and its putative metabolites in plasma during a pilot pharmacokinetic study in rabbits.  相似文献   

13.
A rapid, sensitive, and specific ultra-performance liquid chromatography-tandem mass spectrometry (UPLC/MS/MS) assay method for simultaneous determination of 13 benzodiazepine compounds in human urine was developed and validated. Aliquots of 0.5 mL of urine specimens were used for the analysis and the benzodiazepines were extracted by single step methanol (containing 0.2% formic acid) precipitation and then separated on a BEH C18 (50 mm × 2.1 mm, 1.7 μm) analytical column with the temperature maintained at 45°C. The mobile phases consisted of methanol and water (both containing 0.2% formic acid) and the flow rate was 0.4 mL/min. The TQ detector, equipped with an electrospray ionization ion source, was set up with a positive mode. The acquisitions were performed in multiple-reaction monitoring (MRM) and the limit of quantification was 20 ng/mL for all of the 13 compounds. The low limits of detections (LODs) of the benzodiazepines in this method were between 0.5 and 2 ng/mL. The chromatographic separation time was 4 min and calibration curves in human urine were generated over the range of 20-2000 ng/mL. The method validation parameters such as accuracy, precision, carryover, recovery, stability, and specificity for all of the 13 compounds were within the acceptable range. This method is suitable for the high throughput screening of benzodiazepines in clinical laboratories.  相似文献   

14.
A new drug, quick-acting anti-motion capsule (QAAMC) composed of d-amphetamine sulfate, dimenhydrinate and ginger extraction has been studied for anti-motion-sickness use. We have developed a sensitive, specific liquid chromatography-tandem mass spectrometry (LC-MS/MS) for the quantitative determination of d-amphetamine and diphenhydramine, the main effective components of the QAAMC, using pseudoephedrine as the internal standard. The analytes and internal standard were isolated from 200 microL plasma samples by a simple liquid-liquid extraction (LLE). Reverse-phase HPLC separation was accomplished on a Zorbax SB-C18 column (100 mm x 3.0 mm, 3.5 microm) with a mobile phase composed of methanol-water-formic acid (65:35:0.5, v/v/v) at a flow rate of 0.2 mL/min. The method had a chromatographic total run time of 5 min. A Varian 1200 L electrospray tandem mass spectrometer equipped with an electrospray ionization source was operated in selected reaction monitoring (SRM) mode with the precursor-to-product ion transitions m/z 136.0-->91.0 (D-amphetamine), 256.0-->167.0 (diphenhydramine) and 166.1-->148.0 (IS) used for quantitation. The method was sensitive with a lower limit of quantitation (LLOQ) of 0.5 ng/mL for d-amphetamine and 1 ng/mL for diphenhydramine, with good linearity in the range 0.5-200 ng/mL for D-amphetamine and 1-500 ng/mL for diphenhydramine (r(2)> or =0.9990). All the validation data, such as accuracy, precision, and inter-day repeatability, were within the required limits. The method was successfully applied to pharmacokinetic study of the QAAMC in beagle dogs.  相似文献   

15.
A rapid and sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method has been developed and validated for the estimation of rivastigmine in human plasma. Rivastigmine was extracted from human plasma by using solid-phase extraction technique. Zolpidem was used as the internal standard. A Betabasic-8 column provided chromatographic separation of analytes followed by detection with mass spectrometry. The mass transition ion-pair was followed as m/z 251.20-->206.10, 86.20 for rivastigmine and m/z 308.10-->235.10 for zolpidem. The method involves a rapid solid-phase extraction from plasma, simple isocratic chromatographic conditions and mass spectrometric detection that enables detection at sub-nanogram levels. The proposed method has been validated for a linear range of 0.2-20.0 ng/ml with a correlation coefficient > or =0.9988. The intra-run and inter-run precision and accuracy were within 10.0%. The overall recoveries for rivastigmine and zolpidem were 86.28% and 87.57%, respectively. The total run time was 2.0 min. The developed method was applied for the determination of the pharmacokinetic parameters of rivastigmine following a single oral administration of a 3 mg rivastigmine capsule in 20 healthy male volunteers.  相似文献   

16.
A selective and high throughput liquid chromatography/tandem mass spectrometry (LC-MS/MS) method has been developed and validated to separate, detect and simultaneously quantify lamivudine (3TC), stavudine (d4T) and nevirapine (NVP) in human plasma using metaxalone as internal standard (IS). After solid phase extraction (SPE), the analytes and the IS were chromatographed on a Symmetry C18 (150 mmx3.9 mm i.d., 5 microm particle size) column using 5 microL injection volume with a run time of 4.5 min. An isocratic mobile phase consisting of 0.5% glacial acetic acid in water:acetonitrile (20:80, v/v) was used to separate all these drugs. The precursor and product ions of these drugs were monitored on a triple quadrupole mass spectrometer, operating in the multiple reaction monitoring mode (MRM) without polarity switch. The method was validated over the range of 25-3000 ng/mL for 3TC, 20-2000 ng/mL for d4T and 50-5000 ng/mL for NVP. The absolute recoveries for analytes (>or=86%) and IS (98.12%) achieved from spiked plasma samples were consistent and reproducible. Inter-batch and intra-batch precision (%CV) across four validation runs (LLOQ, LQC, MQC and HQC) was less than 10. The accuracy determined at these levels was within +/-8% in terms of relative error. The method was successfully applied to a pivotal bioequivalence study of [60 (3TC)+12 (d4T)+100 (NVP)] mg dispersible tablets in 60 healthy human subjects under fasting condition.  相似文献   

17.
A high throughput and sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method has been developed and validated for the estimation of bisoprolol in human plasma using multiplexing technique (two HPLC units connected to one MS). Bisoprolol was extracted from human plasma using solid-phase extraction technique using metoprolol as internal standard. A Betabasic 8 column provided chromatographic separation of analytes followed by detection with mass spectrometry. The mass transition ion-pair was followed as m/z 326.2-->116.1 for bisoprolol and m/z 268.2-->191.0 for metoprolol. The method involves a simple multiplexing, rapid solid-phase extraction, simple isocratic chromatography conditions and mass spectrometric detection which enable detection at sub-nanogram levels. The proposed method has been validated for a linear range of 0.5-70.0 ng/mL with correlation coefficient > or =0.9991. The precision and accuracy were within 10% for intra-HPLC runs and inter-HPLC runs. The overall recoveries for bisoprolol and metoprolol were 93.89% and 77.65%, respectively. Total MS run time was 0.90 min only. The developed method was applied for the determination of pharmacokinetic parameters of bisoprolol following a single oral administration of a 10mg bisoprolol tablet in 18 healthy male volunteers.  相似文献   

18.
A simple, sensitive and rapid liquid chromatography/tandem mass spectrometry (LC-MS/MS) method has been developed and validated to quantify griseofulvin in human plasma using propranolol hydrochloride as internal standard (IS). Samples were prepared using solid phase extraction and analysed without drying and reconstitution. The analytes were chromatographed on Hypersil, hypurity C18 reverse phase column under isocratic conditions using 0.05% formic acid in water:acetonitrile (30:70, v/v) as the mobile phase. Total chromatographic run time was 3.0 min. Quantitation was done on a triple quadrupole mass analyzer API-3000, equipped with turbo ion spray interface and operating in multiple reaction monitoring (MRM) mode to detect parent-->product ion transition for analyte and IS. The method was validated for sensitivity, matrix effect, accuracy and precision, linearity, recovery and stability studies. Linearity in plasma was observed over the concentration range 20-3000 ng/mL for griseofulvin. Lower limit of quantification (LLOQ) achieved was 20 ng/mL with precision (CV) less than 10% using 5 microL injection volume. The absolute recovery of analyte (87.36%) and IS (98.91%) from spiked plasma samples was consistent and reproducible. Inter-batch and intra-batch coefficients of variation across four validation runs (LLOQ, LQC, MQC and HQC) was less than 7.5%. The accuracy determined at these levels was within +/-4.2% in terms of relative error. The method was applied to a pilot bioequivalence study of 500 mg griseofulvin tablet in six healthy human subjects under fed condition.  相似文献   

19.
A simple, selective and sensitive isocratic HPLC method with triple quadrupole mass spectrometry detection has been developed and validated for simultaneous quantification of zopiclone and its metabolites in human plasma. The analytes were extracted using solid phase extraction, separated on Symmetry shield RP8 column (150 mm x 4.6 mm i.d., 3.5 microm particle size) and detected by tandem mass spectrometry with a turbo ion spray interface. Metaxalone was used as an internal standard. The method had a chromatographic run time of 4.5 min and linear calibration curves over the concentration range of 0.5-150 ng/mL for both zopiclone and N-desmethyl zopiclone and 1-150 ng/mL for zopiclone-N-oxide. The intra-batch and inter-batch accuracy and precision evaluated at lower limit of quantification and quality control levels were within 89.5-109.1% and 3.0-14.7%, respectively, for all the analytes. The recoveries calculated for the analytes and internal standard were > or = 90% from spiked plasma samples. The validated method was successfully employed for a comparative bioavailability study after oral administration of 7.5 mg zopiclone (test and reference) to 16 healthy volunteers under fasted condition.  相似文献   

20.
Vinorelbine is a semi-synthetic vinca alkaloid with demonstrated high activities against various types of advanced cancer. To support a clinical pharmacokinetic study, a simple, rapid and sensitive method to determine vinorelbine in human plasma was developed using reversed phase liquid chromatography (LC) coupled with electrospray ionization mass spectrometry/mass spectrometry (ESI-MS/MS). Vinorelbine and vinblastine (the internal standard) were extracted from human plasma by one-step liquid-liquid extraction (LLE) with methyl-t-butyl ether. The chromatographic separation was achieved on a Spursil polar-modified C(18) column (50 mm×2.1 mm, 3 μm, Dikma Technologies) with an isocratic mobile phase of a 75:25 (v/v) acetonitrile-4 mmol/L ammonium formate (pH 3.0) mixture at a flow-rate of 0.4 mL/min. The MS/MS detection was performed in the positive ion multiple reaction monitoring (MRM) mode by monitoring the precursor→product ion transitions at m/z 779.4→122.0 and m/z 811.3→224.2 for vinorelbine and the internal standard, respectively. The assay was validated in the range 0.1-200 ng/mL (r>0.997), the lowest level of this range being the lower limit of quantification (LLOQ) based on 50 μL of plasma. The intra- and inter-day precisions were within 6.0%, while the accuracy was within ±4.7% of nominal values. Detection and quantification of both analytes within 2 min make this method suitable for high-throughput analyses. The method was successfully applied to evaluate the systemic pharmacokinetics of vinorelbine after a 20-min intravenous infusion of 25 mg/m(2) of vinorelbine to patients with metastatic breast cancer.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号