首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 32 毫秒
1.
The metatolic fate of silicone gel leaked from an intact or ruptured prosthesis is unknown. In this study, serum was blindly assayed by inductively coupled plasma atomic emission spectroscopy (ICP-AES) for elemental silicon in 72 women with silicone gel breast implants and 55 control women (mean age 48 yr, both groups). Blood was drawn and processed using silicon-free materials. The mean silicon level in controls was 0.13±0.07 mg/L (range 0.06–0.35 mg/L), whereas in implant patients, the mean was significantly higher at 0.28±0.22 mg/L (range 0.06–0.87 mg/L) (P<0.01, Student'st-test with correction for unequal variances). Using the mean of the control group +2 SD as a cutoff for normal range (0.27 mg/L), 25/72 (34.7%) implant patients exceeded this value, compared with 2/55 (3.6%) controls. There was no significant correlation between past rupture of one or both implants, current rupture at the time of the blood draw, or the number of years with implants and silicon levels. The results suggest that serum silicon levels are elevated in many women with silicone gel breast implants. The chemical species involved and kinetics of this elevation remain to be determined.  相似文献   

2.
Little has been published regarding the treatment of patients with long-established capsular contracture after previous submuscular or subglandular breast augmentation. This study reviews 7 years of experience in treating established capsular contracture after augmentation mammaplasty by relocating implants to the "dual-plane" or partly subpectoral position. A retrospective chart review was performed on all patients who were treated for capsular contracture using this technique between 1993 and 1999. Data collected included the date of the original augmentation, the original implant location, date of revision and type of implant used, length of follow-up, outcome, and any ensuing complications. Different surgical techniques were used, depending on whether the prior implant was located in a subglandular or submuscular plane. All patients had revisions such that their implants were relocated to a dual plane, with the superior two thirds or so of the implant located beneath the pectoralis major muscle and the inferior one third located subglandularly. Of 85 patients reviewed, 54 had their original implants in a submuscular position and 31 had their initial augmentation in a subglandular position. Of the 54 patients whose implants were initially submuscular, 23 patients (43 percent) had silicone gel implants, 15 patients (28 percent) had double-lumen implants, and the remaining 16 patients (30 percent) had saline implants. Of the 31 patients whose implants were initially subglandular, 20 patients (65 percent) had silicone gel implants, three patients (10 percent) had double-lumen implants, and the remaining eight patients (26 percent) had saline implants. Fifty-one patients (60 percent) had replacement with saline implants (37 smooth saline, 14 textured saline), whereas 34 (40 percent) had silicone gel implants (seven smooth gel, 27 textured gel). The average time from previous augmentation to revision was 9 years 9 months. The average follow-up time after conversion to the dual-plane position was 11.5 months. Only three of 85 patients required reoperation for complications, all of which involved some degree of implant malposition. Of patients converted to the dual plane, 98 percent were free of capsular contracture and were Baker class I at follow-up, whereas 2 percent were judged as Baker class II. There were no Baker level III or IV contractures at follow-up. The dual-plane method of breast augmentation has proved to be an effective technique for correcting established capsular contracture after previous augmentation mammaplasty. This technique appears to be effective when performed with either silicone or saline-filled implants.  相似文献   

3.
Variability in the properties of silicone gel breast implants.   总被引:4,自引:0,他引:4  
Several generations of silicone gel breast implants have been produced by implant manufacturers. The primary material usually viewed as the base material in the manufacture of implants is polydimethylsiloxane. Polymeric reactions are notorious for their variability and nonuniformity. The elastomer used in different types of implants can have vastly different properties. Furthermore, the material properties associated with a particular type of implant can vary considerably from one lot to the next. Considering the various designs, styles, and manufacturing techniques associated with silicone gel implants, knowledge of the original properties of the implants before implantation is important in determining the effects of aging in vivo. This study was conducted to investigate differences in key mechanical and chemical properties of silicone gel breast implant materials. The two types of implants chosen for analysis were Silastic I and Silastic II control implants. Material property data were determined for both types of controls and significant differences were found in their values. Lot-to-lot variability was also investigated and found to be significant.  相似文献   

4.
Collis N  Sharpe DT 《Plastic and reconstructive surgery》2000,105(6):1979-85; discussion 1986-9
Concern has been expressed over the long-term integrity of silicone gel breast implants. There are no large series representing experience with these implants outside of the United States. A retrospective case note review of explanted silicone breast implants was performed; 478 implants have been explanted during the past 11 years and relate to the use of these devices since 1971. Loss of implant integrity was not simply related to its age in vivo. Failure was more likely with implants of the late 1970s and early 1980s (second generation) and with subpectoral placement. Implant failure was independent of capsular contracture as the indication for removal (p = 0.09). There is no evidence that the currently used textured silicone gel breast implants are subject to the same loss of integrity as previous examples of these devices. The life span of these implants, the first of which are approaching 10 years in vivo, is at present unknown. Information concerning the integrity of silicone gel breast implants is essential in the current climate for counseling of both new and old implant recipients.  相似文献   

5.
Spear SL  Elmaraghy M  Hess C 《Plastic and reconstructive surgery》2000,105(4):1542-52; discussion 1553-4
The earliest silicone breast implants were smooth-surface, silicone rubber devices filled with either silicone gel or saline. Because of persistent problems with capsular contracture, polyurethane-covered silicone implants were developed as an alternative. Particularly in the short run, these alternatives proved highly successful at reducing the incidence of capsular contracture. By 1990, polyurethane-covered implants were rapidly becoming the preferred implant choice of many plastic surgeons, but for legal, regulatory, financial, and safety reasons they were withdrawn from the market by Bristol-Myers in 1991. Meanwhile, during the late 1980s, surface texturing and improved materials became available on other silicone breast implants and expanders. Most studies suggest that textured-surface silicone gel-filled implants, saline-filled implants, and tissue expanders have less frequent capsular contracture than their smooth-surface counterparts.  相似文献   

6.
Epidemiologic evidence does not support an association between silicone breast implants and connective tissue or other rheumatic diseases. However, a recent study has suggested that women with ruptured implants may be at increased risk of developing fibromyalgia. An analysis of adverse health outcomes according to breast implant rupture status was conducted in 238 unselected Danish women with cosmetic silicone breast implants. Ninety-two of the women had definite implant rupture, and 146 had intact implants as determined by magnetic resonance imaging. Before undergoing imaging, the women provided blood samples and completed a self-administered questionnaire. Women with ruptured implants overall, and the subgroup with extracapsular ruptures (n = 23), were compared with women with intact implants regarding a number of self-reported diseases and symptoms and the presence of specific autoantibodies, such as antinuclear antibodies, rheumatoid factor, and cardiolipin immunoglobulin G and M antibodies. Overall, there were no differences in the occurrence of self-reported diseases or symptoms or in the presence of autoantibodies between women with intact implants and women with ruptured implants, including extracapsular rupture. The only exception was capsular contracture, which was reported six times more frequently by women with extracapsular ruptures than by women with intact implants (OR, 6.3; 95 percent CI, 1.7 to 23.5). In conclusion, this study of unselected women with silicone breast implants could establish no association between silicone implant rupture and specific diseases or symptoms related to connective tissue disease or other rheumatic conditions, except for an excess of capsular contracture among women with extracapsular rupture.  相似文献   

7.
Current implants for breast augmentation containing silicone gel, saline, or both can totally obscure mammographic detection of microcalcifications and soft-tissue masses. To investigate the possibility of developing a more radiolucent implant, radiographs were obtained of silicone shells that contained silicone gel, saline, silicone gel and saline, polyurethane-covered silicone gel, gelatin, sunflower oil, and peanut oil. All radiographs were obtained using a Siemens Mammomat by placing the implant over an American College of Radiology mammography phantom. Results were measured by the ability to visualize or resolve the artifacts in the mammography phantom. The silicone shell alone minimally altered artifact resolution. Silicone shells filled with silicone gel, silicone gel and saline, saline alone, polyurethane-covered silicone gel, and gelatin were equal in radiodensity and completely obscured all phantom artifacts. Silicone shells filled with peanut oil and sunflower oil had equal radiodensity and allowed visualization of large microcalcifications and some soft-tissue masses. Current implants used for augmentation mammaplasty can totally obscure mammographic detection of microcalcifications and soft-tissue masses. A more radiolucent breast implant is possible, and further research is needed to define the best filler material and test its biocompatibility.  相似文献   

8.
Long-term use of polyurethane breast prostheses: a 14-year experience   总被引:1,自引:0,他引:1  
I have used polyurethane prostheses for the past 14 years, implanting 220 implants into 130 patients who desired breast reconstruction after subcutaneous mastectomy or cancer ablation or simply breast augmentation. I theorize that a polyurethane-covered implant resists contracture, retaining its compressibility because the fibroblasts proliferate into the polyurethane in many different directions. When the fibrils contract, the forces of contracture counterbalance one another, resisting contracture. However, when smooth prostheses are implanted, fibrils are directed in a circular fashion around the implant and naturally contract, leading to firmer breasts. There were 115 prostheses inserted following subcutaneous mastectomy, and 22 percent developed contracted capsules. Seven implants became exposed because of skin necroses; one was removed because of a Staphylococcus infection; and two patients developed a combination of polyurethane and silicone granulomas. These developed only with the earlier implant, where there was shedding of the polyurethane sponge layer and silicone bled from the low-viscosity silicone used in the earlier implants. No granulomas were noted with the currently used Surgitek Replicon implant. Eighty-five breasts were reconstructed after cancer ablation with polyurethane implants, and the contracture rate was 2.3 percent. Other complications were minimal. A smaller group of patients had augmentation mammaplasty, and 20 prostheses were placed in 10 patients. A 15 percent contracture rate was noted in this group. In this study, 82 percent of patients were followed for up to 14 years. Capsular contractures occurred in 30 implants between 1 and 11 years, for an average recurrence at 6.3 years. The overall contracture rate was 13 percent. Other complications were minimal. All implants were placed subcutaneously or subglandularly, and all were drained.  相似文献   

9.
Implant rupture is a well-known complication of breast implant surgery that can pass unnoticed by both patient and physician. To date, no prospective study has addressed the possible health implications of silicone breast implant rupture. The aim of the present study was to evaluate whether untreated ruptures are associated with changes over time in magnetic resonance imaging findings, serologic markers, or self-reported breast symptoms. A baseline magnetic resonance imaging examination was performed in 1999 on 271 women who were randomly chosen from a larger cohort of women having cosmetic breast implants for a median period of 12 years (range, 3 to 25 years). A follow-up magnetic resonance imaging examination was carried out in 2001, excluding women who underwent explantation in the period between the two magnetic resonance imaging examinations (n = 44). On the basis of these examinations, the authors identified 64 women who had at least one ruptured implant at the first magnetic resonance imaging examination and, for comparison, all women who had intact implants at both examinations (n = 98). Magnetic resonance images from the two examinations were compared and changes in rupture configuration were evaluated. Comparisons were also made for self-reported breast symptoms occurring during the study period and for changes in serum values of antinuclear antibodies, rheumatoid factor, and cardiolipin antibodies immunoglobulin G and immunoglobulin M. The majority of the women with implant rupture had no visible magnetic resonance imaging changes of their ruptured implants. For 11 implants (11 percent) in 10 women, the authors observed progression of silicone seepage, either as a conversion from intracapsular into extracapsular rupture (n = 7), as progression of extra-capsular silicone (n = 3), or as increasing herniation of the silicone within the fibrous capsule (n = 1); however, in most cases, these changes were minor. Some changes could be ascribed to trauma, but others seemed spontaneous. There was no increase in levels of autoantibodies during the study period in either study group. Women with untreated implant ruptures reported a significant increase in nonspecific breast changes (odds ratio, 2.1; 95 percent confidence interval, 1.2 to 3.8) compared with women without ruptures. On the basis of this first study of women with untreated silicone breast implant rupture, the authors conclude that implant rupture is a relatively harmless condition, which only rarely progresses and gives rise to notable symptoms. Even so, because of a small risk of silicone spread, the authors suggest that women with implant ruptures be followed clinically, if not operated on. Because implant ruptures often occur asymptomatically, any woman with silicone implants, regardless of rupture status, should be evaluated at regular intervals.  相似文献   

10.
In this paper, a qualitative comparison between two types of dental implants with respect to their behaviour under immediate loading is presented. This analysis has been carried out using the finite element method. Since micromotions (and not the load) are responsible of the appearance of a fibrous interface avoiding osseointegration, the relative displacement between the bone surface and the implant has been the main variable analyzed at different loading states and for the two implant types here considered. The implants analyzed differ in their mechanical behavior: rigid or resilient. Their main difference lies in the joining between the different pieces that make up the dental system. While in the rigid implant all the pieces are screwed, in the resilient implant a relative displacement between the pieces is allowed, with the additional introduction of a silicone gasket that acts like the periodontal ligament. Both implants were considered with a similar geometry and under two different loading scenarios, one equivalent to the force of chewing applied to a molar and another which corresponds to a premolar. For the resilient implant, a hyperelastic behaviour for the silicone and contact conditions between the different mobile parts of the implant are considered. The displacements of the emerging-body in both designs are also compared with the values obtained by several authors. However, the results show that both implants fulfill the constraint of the immediate loading protocol. The micromotions of the resilient implant are lower to those of the rigid one, favouring therefore a good osseointegration process while keeping the stresses in the implant under admissible maximum values.  相似文献   

11.
Silicone implants are used for prosthetic arthroplasty of metacarpophalangeal (MCP) joints severely damaged by rheumatoid arthritis. Different silicone elastomer MCP implant designs have been developed, including the Swanson and the NeuFlex implants. The goal of this study was to compare the in vitro mechanical behavior of Swanson and NeuFlex MCP joint implants. Three-dimensional (3D) finite element (FE) models of the silicone implants were modeled using the commercial software ANSYS and subjected to angular displacement from 0 deg to 90 deg. FE models were validated using mechanical tests of implants incrementally bent from 0 deg to 90 deg in a joint simulator. Swanson size 2 and 4 implants were compared with NeuFlex size 10 and 30 implants, respectively. Good agreement was observed throughout the range of motion for the flexion bending moment derived from 3D FE models and mechanical tests. From 30 deg to 90 deg, the Swanson 2 demonstrated a greater resistance to deformation than the NeuFlex 10 and required a greater bending moment for joint flexion. For larger implant sizes, the NeuFlex 30 had a steeper moment-displacement curve, but required a lower moment than the Swanson 4, due to implant preflexion. On average, the stress generated at the implant hinge from 30 deg to 90 deg was lower in the NeuFlex than in the Swanson. On average, starting from the neutral position of 30 deg for the preflexed NeuFlex implant, higher moments were required to extend the NeuFlex implants to 0 deg compared with the Swanson implants, which returned spontaneously to resting position. Implant toggling within the medullary canals was less in the NeuFlex than in the Swanson. The differential performance of these implants may be useful in implant selection based on the preoperative condition(s) of the joint and specific patient functional needs.  相似文献   

12.
Capsular contracture results in dissatisfaction and deformity among the 2 million women who have had silicone implants. The literature describes contracture rates as high as 74 percent. I present a comparison of rates and incidences of contracture in patients augmented with smooth and textured double-lumen silicone implants. A total of 165 "smooth" and 63 "textured" implant patients were included in this study, which spans 12 years, 1978-1990. All patients underwent bilateral aesthetic augmentation performed by the same surgeon. Of the 165 smooth implant patients, 74 (44.8 percent) experienced contractures requiring treatment. Of the 63 textured implant patients, 3 (4.8 percent) previous contracture patients experienced sudden fibrosis within 3 months. All others remained soft. It appears that deeply textured silicone surfaces delay or decrease the rate and incidence of clinical capsular contracture, at least for 2 years.  相似文献   

13.
S Bern  A Burd  J W May 《Plastic and reconstructive surgery》1992,89(6):1037-42; discussion 1043-4
Capsular contracture remains the major complication of reconstructive and aesthetic breast surgery. The purpose of this investigation was to determine if a silicone implant with a textured surface will form a capsule of significantly different biophysical and histologic properties than conventional smooth silicone. Thirty smooth and 30 textured silicone tissue expanders were implanted under the panniculus carnosus of rabbits. After 3 months, measurements related to contracture were performed on anesthetized animals in an investigator-blinded, controlled manner. Intraexpander pressures were measured as saline was injected over time. We found a significant correlation between intraexpander pressures, applanation tonometry, and Baker class. Histology revealed a thicker, more adherent, and inflammatory capsule around the textured silicone implants as compared with the smooth silicone implants. Dynamic pressures were plotted against volume of saline within the two types of implants. Statistical analysis revealed that the textured implants form a tighter and thicker capsule than the smooth implants after 3 months of observation (p less than 0.005).  相似文献   

14.
The chest-wall deformity associated with Poland's syndrome was reconstructed in eight male patients 16 to 38 years old (average age 20 years). Follow-up ranged from 1 to 10 years. Two patients had custom silicone implants placed subcutaneously. In one of these patients, the edge of the implant could be seen. Three patients had transfer of an ipsilateral pedicled latissimus dorsi muscle flap with intact thoracodorsal nerve. All these patients had noticeable atrophy of the flap, and one underwent subsequent implantation of a custom silicone implant beneath the flap. Three other patients had a custom silicone implant covered immediately by a latissimus dorsi muscle flap. All four patients who had a combination of silicone implant and latissimus dorsi muscle flap had satisfactory correction of their deformity.  相似文献   

15.
The increase, in the last two decades, in the application of silicones (polysiloxanes) and inorganic silicon compounds in medicine and the food industry, has exposed the human body to extensive contacts with these substances. Most silicone breast implants contain a gel consisting of a crosslinked silicone elastomer swollen by silicone oil (PDMS). Diffusion of PDMS through the silicone elastomer envelope and rupture of the envelope with release of the gel contents both occur clinically. The amount and distribution of silicone compounds in various tissues are key issues in the assessment of health problems connected with silicone implants. We have measured by GFAAS the Si content of tissues from normal and implant patients and the organic solvent extractable Si levels (assumed to be silicone), using careful control of sample collection and preparation. Whole blood levels were: implant patients mean 38.8 (SD 25.6) (microg/kg), controls mean 24.2 (SD 26.7) (microg/kg) in one study and subsequently 103.8 (SD 112.1) and 74.3 (SD 86.5) (microg/kg) in another study. Capsular tissue levels were: gel implants 25047 (SD 39313) (mg/kg of dry tissue), saline implants 20.0 (SD 27.3) (mg/kg of dry tissue) and controls 0.24 (SD 0.39) (mg/kg of dry tissue). Breast milk levels were: implant patients mean 58.7 (SD 33.8) (microg/kg), controls mean 51.1 (SD 31.0) (microg/kg); infant formula mean was 4.40 (mg/kg). Various precautions were undertaken to avoid Si contamination in this work, the most important being a) the use of a Class 100 laboratory for sample preparation and b) application of strict and elaborate washing procedure for specimen collection tools and laboratory plasticware. This data demonstrated that to properly interpret the importance of these numbers for human health, a larger study of "normal" levels of Si in human tissues should be undertaken and factors such as diet, water, race and geographical location should be considered.  相似文献   

16.
The implant-tissue response to the silicone gel mammary prosthesis requires a more thorough evaluation in light of recent concerns related to human connective-tissue diseases, contracture, infection, and neoplasia. The silicone prosthesis is not a homogeneous implant but is a milieu of various silicone chemistries. Silicone polymer precursors and prosthesis components (silicone shells, shells extracted of their low-molecular-weight components, silica-free silicone, silicone oil, fumed silica, and silicone extract) were implanted subcutaneously using a nonhemorrhagic technique into the backs of Lew/SsN rats (n = 90), two implants per rat, for periods of 7, 14, 28, 56, and 90 days for a total of 6 implants per material per time period. Histologic analysis was performed on specimens from the harvested soft tissue. The intensity of the cellular and capsular response was lowest for the silicone oil and increased as the material's molecular weight increased and material compliance decreased. Fumed silica elicited the most highly reactive cellular response. From this study it is apparent that the polymer's molecular weight influences its migration, encapsulation, and intensity of cellular response. Further, the silicone extract distillate elicited a highly intense cellular response with pronounced lymphocyte invasion. The human relevance of this work awaits further correlation with implant retrieval and in vivo performance.  相似文献   

17.
A retrospective cohort study was performed in Sweden to evaluate the possibility that an individual symptom or constellation of illness symptoms related to silicone occurs in women after breast implant surgery. A random sample (n = 2500) of all women in the Swedish national implant registry who underwent breast augmentation surgery with alloplastic breast implants during the years 1965 through 1993 was compared with a sample (n = 3500) of women who underwent breast reduction surgery during the same period, frequency matched to the implant patients for age and calendar year at the time of surgery. In total, 65 percent of the breast implant patients (n = 1546) and 72 percent of the breast reduction patients (n = 2496) completed a self-administered questionnaire covering 28 rheumatologic and other symptoms and lifestyle and demographic factors. Practically all of the 28 symptoms inquired about were reported more often by women in the breast implant cohort, with 16 (57 percent) significantly more common in breast implant recipients. In contrast, few significant differences or consistent patterns were observed in the length of time since the implant and in the type (silicone or saline) or volume of the implant. Although women with breast implants report a multitude of symptoms more often than women who have breast reduction surgery, the lack of specificity and absence of dose-response relationships suggest that the excess of reported symptoms is not causally related to cosmetic implants.  相似文献   

18.
A single patient is presented in whom breast reconstruction after mastectomy for breast cancer has been achieved by sequential use of soft-tissue expansion followed by permanent silicone implant placement and thoracic flap advancement to define the inframammary fold. This procedure may play a useful role in patients in whom other, more complex methods of breast reconstruction are not selected or indicated and in particular in patients in whom bilateral silicone implants are utilized.  相似文献   

19.
Zambacos GJ  Nguyen D  Morris RJ 《Plastic and reconstructive surgery》2004,114(3):706-10; discussion 711-2
Irrigation of breast implants and breast implant pockets with various solutions, including povidone iodine, has been a common practice among plastic surgeons for many years. Recent reports of potential weakening of silicone tubing have led the Food and Drug Administration to pronounce any contact of povidone iodine with breast implants a contraindication. An in vitro experimental study was undertaken to assess the effect of povidone iodine on the physical properties of silicone breast implant shells. Identical specimens were obtained from the shells of silicone breast implants according to published standards. The specimens were randomly assigned to eight groups of five and incubated in various solutions of decreasing concentration of povidone iodine (10% to 0.01%), and a control group (0.9% saline) was used. The containers were stored in a warming cabinet at 37 degrees C for 4 weeks. Testing of the specimens for tensile strength following 4 weeks of incubation showed no significant difference among any of the groups, including the control group. In addition, no correlation was shown between the concentration of the solution used and the tensile strength of the specimens.  相似文献   

20.
This study analyzed the shells of single-lumen silicone gel breast implants within the general context of device durability in vivo. The investigation included the major types of gel-filled implants that were manufactured in the United States in a 30-year period. The implants analyzed were Cronin seamed (two explants and one control), Silastic 0 and Silastic I (18 explants and seven controls), and Silastic II (22 explants and 43 controls). The biodurability of the explants was investigated with measurements of the mechanical and chemical properties of the various types of silicone gel control and explanted shells, with implantation times ranging from 3 months to 32 years. The shell properties measured for the controls and explants included the stress-strain relationships, tensile strength, elongation, tear resistance, moduli, cross-link density, and amount of extractable material in the shell. In addition, the mechanical properties of shells that had been extracted with hexane were analyzed for both explants and control implants. The silicone gel explants investigated in this study included some of the oldest explants of the various major types that have been tested to date. For assessment of long-term implantation effects, the data obtained in this study were combined with all known data from other institutions on the various major types of gel implants. The study also addressed the failure mechanisms associated with silicone gel breast implants. The results of the study demonstrated that silicone gel implants have remained intact for 32 years in vivo and that degradation of the shell mechanical and chemical properties is not a primary mechanism for silicone gel breast implant failure.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号