首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
Monoclonal antibodies (mAb) are not only useful reagents but also represent a promising type of therapeutics due to their high affinity and exquisite specificity for their antigens. A critical step in mAb generation is to identify antigen-specific antibodies. Although enzyme-linked immunosorbent assay (ELISA) has been broadly applied for antibody selection against secreted antigens, an inherent disadvantage for ELISA is the difficulty in identifying antibodies that recognize the native conformation of cell surface antigens. To overcome this drawback, the authors have developed a high-throughput cell-based antibody binding assay using fluorometric microvolume assay technology (FMAT). This method offers a homogeneous assay for detection of antibody binding to its antigen on the cell surface. To distinguish antibodies that bind to antigen on the cell surface from those that bind nonspecifically to cells, the binding is assessed using both antigen-expressing cells and related cells devoid of the antigen expression. This assay can detect antibodies at a concentration as low as 5 ng/mL and cell surface antigen as low as 9000 copies per cell. Results demonstrate that the FMAT method provides a sensitive and homogeneous assay to detect antibody binding to cell surface antigens and is amenable for high-throughput hybridoma selection.  相似文献   

2.
We have developed a novel fluorescence-based homogeneous binding assay for high-throughput screening of chemical compounds. In this assay, a Cy5- or Cy5.5-labeled ligand binds to receptor immobilized on a particle, either a bead or a cell. The resulting localized signal can be detected by a modified microvolume fluorimeter (MVF). When a molecule which competes with the labeled ligand is present, the localized fluorescence on cells or beads is reduced. Image processing software enumerates events and analyzes fluorescence intensity. We describe MVF assays for the IL-1 and IL-5 receptors. Using synthetic peptides with a range of affinities for the IL-1 receptor, we obtained IC(50) data consistent with those determined by radioligand binding assays. Because the image processing software can discriminate among events with different diameters, we were able to develop a multiplex assay, in which the IL-1R and IL-5R assays were carried out in the same well with each receptor immobilized on a different size of bead. IC(50) values generated in the multiplex assay for ligands specific to each receptor were comparable to those determined independently. Finally, similar IC(50) values were obtained in a 16-microl volume in an 864-well plate. This homogeneous, nonradioactive, miniaturizable, and multiplex-capable assay holds much promise for screening of combinatorial libraries and compound collections.  相似文献   

3.
We have developed a fluorescence-based mix and read method for the quantitative determination of receptor-ligand binding interactions. This method was used to determine IC(50) values for peptide ligands of two endogenous seven-transmembrane receptors that are expressed in cultured human cancer cells. Substance P, neurokinin A, and galanin were labeled with Cy5 and were shown to retain their native binding affinities. The cell-associated fluorescence was quantified using a fluorometric microvolume assay technology (FMAT) scanner that was designed to perform high-throughput screening assays in multiwell plates with no wash steps. The binding of fluorescently labeled substance P and neurokinin A was tested on the human astrocytoma cell line UC11 that expresses endogenous NK(1) receptor. Galanin binding was measured on endogenous galanin type 1 receptors in the Bowes neuroblastoma cell line. IC(50) values were determined for substance P, neurokinin A, and galanin and were found to correspond well with reported values from radioligand binding determinations. To demonstrate FMAT as instrumentation for high-throughput screening, it was utilized to successfully identify individual wells in a 96-well plate in which Cy5-substance P binding in UC11 cells was competed with unlabeled substance P. In addition, we developed a two-color multiplex assay in which cells individually expressing neuropeptide Y and substance P receptors were mixed in the same well. In this assay, the fluorescent ligands substance P and neuropeptide Y bound only to their respective cell types and binding was specifically competed. Therefore, two different seven-transmembrane receptor targets can be tested in one screen to minimize reagent consumption and increase throughput.  相似文献   

4.
Nicotinamide adenine dinucleotide (NAD) plays a crucial role in many cellular processes. As the rate-limiting enzyme of the predominant NAD biosynthesis pathway in mammals, nicotinamide phosphoribosyltransferase (Nampt) regulates the cellular NAD level. Tumor cells are more sensitive to the NAD levels, making them more susceptible to Nampt inhibition than their nontumorigenic counterparts. Experimental evidence has indicated that Nampt might have proangiogenic activity and supports the growth of some tumors, so Nampt inhibitors may be promising as antitumor agents. However, only four Nampt inhibitors have been reported, and no high-throughput screening (HTS) strategy for Nampt has been proposed to date, largely limiting the drug discovery targeting Nampt. Therefore, the development of a robust HTS strategy for Nampt is both imperative and significant. Here we developed a fluorometric method for a Nampt activity assay by measuring the fluorescence of nicotinamide mononucleotide (NMN) derivative resulting from the enzymatic product NMN through simple chemical reactions. Then we set up an HTS system after thorough optimizations of this method and validated that it is feasible and effective through a pilot screening on a small library. This HTS system should expedite the discovery of Nampt inhibitors as antitumor drug candidates.  相似文献   

5.
To take advantage of the growing knowledge of cellular signaling pathways, modern-day drug discovery faces an increasing challenge to develop assays to screen for compounds that modulate protein-protein interactions. One bottleneck in achieving this goal is a lack of suitable and robust assay technologies amenable to a high-throughput format. In this report, we describe how we utilized Alphascreen trade mark technology to develop a high-throughput assay to monitor ligand binding to a member of the tumor necrosis factor receptor superfamily. We expressed a fusion protein consisting of the extracellular domain of the OX40 receptor with the constant domains of human IgG. In the presence of OX40 ligand, we determined a binding affinity constant consistent with reported values and optimized the protocol to develop a simple, homogeneous, and sensitive binding assay in a 384-well format. Finally, we assessed if this system could identify small peptides capable of inhibiting the OX40 receptor and ligand interaction. The results showed that the assay was able to detect such peptides and could be used to launch a high-throughput screening campaign for small molecules able to prevent OX40 receptor activation.  相似文献   

6.
Cell-based assays for G-protein-coupled receptor (GPCR) activation applied in high-throughput screening (HTS) monitor various readouts for second messengers or intracellular effectors. Recently, our understanding of diverging signaling pathways downstream of receptor activation and the capability of small molecules to selectively modulate signaling routes has increased substantially, underlining the importance of selecting appropriate readouts in cellular functional screens. To minimize the rate of false negatives in large-scale screening campaigns, it is crucial to maximize the chance of a ligand being detected, and generally applicable methods for detecting multiple analytes from a single well might serve this purpose. The few assays developed so far based on multiplexed GPCR readouts are limited to only certain applications and usually rely on genetic manipulations hindering screening in native or native-like cellular systems. Here we describe a more generally applicable and HTS-compatible homogeneous assay based on the combination of fluorometric detection of [Ca2+] with subsequent homogeneous time-resolved fluorescence (HTRF) cAMP readout in the same well. Besides describing development and validation of the assay, using a cell line recombinantly expressing the human PTH1 receptor screening of a small library is also presented, demonstrating the robustness and HTS compatibility of the novel paradigm.  相似文献   

7.
Serum-free differentiation protocols of human embryonic stem cells (hESCs) offer the ability to maximize reproducibility and to develop clinically applicable therapies. We developed a high-throughput, 96-well plate, four-color flow cytometry-based assay to optimize differentiation media cocktails and to screen a variety of conditions. We were able to differentiate hESCs to all three primary germ layers, screen for the effect of a range of activin A, BMP4, and VEGF concentrations on endoderm and mesoderm differentiation, and perform RNA-interference (RNAi)-mediated knockdown of a reporter gene during differentiation. Cells were seeded in suspension culture and embryoid bodies were induced to differentiate to the three primary germ layers for 6 days. Endoderm (CXCR4(+)KDR(-)), mesoderm (KDR(+)SSEA-3(-)), and ectoderm (SSEA-3(+)NCAM(+)) differentiation yields for H9 cells were 80 ± 11, 78 ± 7, and 41 ± 9%, respectively. Germ layer identities were confirmed by quantitative PCR. Activin A, BMP4, and bFGF drove differentiation, with increasing concentrations of activin A inducing higher endoderm yields and increasing BMP4 inducing higher mesoderm yields. VEGF drove lateral mesoderm differentiation. RNAi-mediated knockdown of constitutively expressed red fluorescent protein did not affect endoderm differentiation. This assay facilitates the development of serum-free protocols for hESC differentiation to target lineages and creates a platform for screening small molecules or RNAi during ESC differentiation.  相似文献   

8.
G-protein-coupled receptors (GPCRs) represent one of the largest gene families in the human genome and have long been regarded as valuable targets for small-molecule drugs. The authors describe a new functional assay that directly monitors GPCR activation. It is based on the interaction between beta-arrestin and ligand-activated GPCRs and uses enzyme fragment complementation technology. In this format, a GPCR of interest is fused to a small (approximately 4 kDa), optimized alpha fragment peptide (termed ProLink) derived from beta-galactosidase, and beta-arrestin is fused to an N-terminal deletion mutant of beta-galactosidase (termed the enzyme acceptor [EA]). Upon activation of the receptor, the beta-arrestin-EA fusion protein binds the activated GPCR. This interaction drives enzyme fragment complementation, resulting in an active beta-galactosidase enzyme, and thus GPCR activation can be determined by quantifying beta-galactosidase activity. In this report, the authors demonstrate the utility of this technology to monitor GPCR activation and validate the approach using a Galphai-coupled GPCR, somatostatin receptor 2. Potential application to high-throughput screens in both agonist and antagonist screening modes is exemplified.  相似文献   

9.
To study the biology of regulators of G-protein signaling (RGS) proteins and to facilitate the identification of small molecule modulators of RGS proteins, the authors recently developed an advanced yeast 2-hybrid (YTH) assay format for GalphaZ and RGS-Z1. Moreover, they describe the development of a multiplexed luciferase-based assay that has been successfully adapted to screen large numbers of small molecule modulators of protein-protein interactions. They generated and evaluated 2 different luciferase reporter gene systems for YTH interactions, a Gal4 responsive firefly luciferase reporter gene and a Gal4 responsive Renilla luciferase reporter gene. Both the firefly and Renilla luciferase reporter genes demonstrated a 40- to 50-fold increase in luminescence in strains expressing interacting YTH fusion proteins versus negative control strains. Because the firefly and Renilla luciferase proteins have different substrate specificity, the assays were multiplexed. The multiplexed luciferase-based YTH platform adds speed, sensitivity, simplicity, quantification, and efficiency to YTH high-throughput applications and therefore greatly facilitates the identification of small molecule modulators of protein-protein interactions as tools or potential leads for drug discovery efforts.  相似文献   

10.
Glycosyltransferases catalyze the transfer of a monosaccharide unit from a nucleotide or lipid sugar donor to polysaccharides, lipids, and proteins in a stereospecific manner. Considerable effort has been invested in engineering glycosyltransferases to diversify sugar-containing drugs. An important requirement for glycosyltransferase engineering is the availability of a glycosyltransferase assay system for high-throughput screening of glycosyltransferase mutants. In this study, a general glycosyltransferase assay system was developed based on an ATP sensor. This system showed submicromolar sensitivity and compatibility with both purified enzymes and crude cell extracts. The assay system will be useful for glycosyltransferase engineering based on high-throughput screening, as well as for general glycosyltransferase assays and kinetics.  相似文献   

11.
12.
The authors have previously reported a homogeneous time-resolved fluorescence proximity immunoassay for estradiol. The assay was based on luminescence resonance energy transfer between a long lifetime fluorescent europium(III) chelate-dyed nanoparticle donor and a short lifetime, near-infrared fluorescent acceptor. The energy transfer prolonged the lifetime of the sensitized acceptor emission, and the fluorescence of the acceptor was measured using a time-resolved detection. The developed immunoassay was employed to screen inhibitors for enzyme 17beta-hydroxysteroid dehydrogenase type 1. The enzyme overexpressed in MCF-7 cells catalyzed a reversible conversion of estroneto17beta-estradiol. The inhibition efficiency of the tested molecule was obtained by comparing the final concentration of converted estradiol after 60 min of conversion reaction in a sample and in a conversion control not containing an inhibitor. The Zbeta factor calculated using the E2 concentrations of the homogeneous assay was 0.64, demonstrating a relatively good performance of the assay. The results from the homogeneous assay were comparable with the results obtained using radioactively labeled estrone as a substrate and high-performance liquid chromatography (HPLC) separation of estrone and converted estradiol after the enzyme reaction. Thus, this homogeneous assay can simplify the primary screening of potential new drug molecules by replacing a tedious radiometric HPLC method.  相似文献   

13.
We have developed a homogeneous high-capacity assay format for measuring integrin- and selectin-dependent cell binding to immobilized ligand using V-well microtiter plates. 2',7'-Bis(2-carboxyethyl)-5-(and-6)-carboxylfluorescence, acetoxymethylester-labeled cells are added to ligand-coated V-shaped microtiter wells. Bound cells are separated from free cells using centrifugal force to produce shear stress. Nonadherent cells accumulate in the nadir of the well and are measured using a fluorescence plate reader. Antibody or low-molecular-weight inhibitors of either the ligand or the cell surface receptor result in less cell binding, more cells in the pellet, and increased signal. The optimization and validation of the very late antigen-4/vascular cell adhesion molecule-1 assay is described in detail. We demonstrate that this assay can be rapidly adapted to measure other integrin- and selectin-mediated interactions. This assay format has several advantages over conventional assays. The centrifugal process is biologically relevant and eliminates the washing steps to remove nonadherent cells that can cause well-to-well and plate-to-plate variation. Because the assay is robust with a high signal-to-noise ratio and low variability, it is ideally suited for studying multiple parameters of cell adhesion and for high capacity screening.  相似文献   

14.
Long QT syndrome, either inherited or acquired from drug treatments, can result in ventricular arrhythmia (torsade de pointes) and sudden death. Human ether-a-go-go-related gene (hERG) channel inhibition by drugs is now recognized as a common reason for the acquired form of long QT syndrome. It has been reported that more than 100 known drugs inhibit the activity of the hERG channel. Since 1997, several drugs have been withdrawn from the market due to the long QT syndrome caused by hERG inhibition. Food and Drug Administration regulations now require safety data on hERG channels for investigative new drug (IND) applications. The assessment of compound activity on the hERG channel has now become an important part of the safety evaluation in the process of drug discovery. During the past decade, several in vitro assay methods have been developed and significant resources have been used to characterize hERG channel activities. However, evaluation of compound activities on hERG have not been performed for large compound collections due to technical difficulty, lack of throughput, and/or lack of biological relevance to function. Here we report a modified form of the FluxOR thallium flux assay, capable of measuring hERG activity in a homogeneous 1536-well plate format. To validate the assay, we screened a 7-point dilution series of the LOPAC 1280 library collection and reported rank order potencies of ten common hERG inhibitors. A correlation was also observed for the hERG channel activities of 10 known hERG inhibitors determined in this thallium flux assay and in the patch clamp experiment. Our findings indicate that this thallium flux assay can be used as an alternative method to profile large-volume compound libraries for compound activity on the hERG channel.  相似文献   

15.
There is an increasing demand for assay technologies that enable accurate, cost-effective, and high-throughput measurements of drug–target association and dissociation rates. Here we introduce a universal homogeneous kinetic probe competition assay (kPCA) that meets these requirements. The time-resolved fluorescence energy transfer (TR–FRET) procedure combines the versatility of radioligand binding assays with the advantages of homogeneous nonradioactive techniques while approaching the time resolution of surface plasmon resonance (SPR) and related biosensors. We show application of kPCA for three important target classes: enzymes, protein–protein interactions, and G protein-coupled receptors (GPCRs). This method is capable of supporting early stages of drug discovery with large amounts of kinetic information.  相似文献   

16.
Hydroxynitrile lyases (Hnls) are important biocatalysts for the synthesis of optically pure cyanohydrins, which are used as precursors and building blocks for a wide range of high price fine chemicals. Although two Hnl enzymes, from the tropical rubber tree Hevea brasiliensis and from the almond tree Prunus amygdalus, are already used for large scale industrial applications, the enzymes still need to be improved and adapted to the special demands of industrial processes. In many cases directed evolution has been the method of choice to improve enzymes, which are applied as industrial biocatalysts. The screening procedure is the most crucial point in every directed evolution experiment. Herein, we describe the successful development of a novel screening assay for Hnls and its application in high-throughput screening of Escherichia coli mutant libraries. The new assay allows rapid screening of mutant libraries and facilitates the discovery of improved enzyme variants. Hnls catalyze the cleavage of cyanohydrins to hydrocyanic acid and the corresponding aldehyde or ketone. The enzyme assay is based on the detection of hydrocyanic acid produced, making it an all-purpose screening assay, without restriction to any kind of substrate. The gaseous HCN liberated within the Hnl reaction is detected by a visible colorimetric reaction. The facile, highly sensitive and reproducible screening method was validated by identifying new enzyme variants with novel substrate specificities.  相似文献   

17.
Transglutaminases (TGs) are widely distributed enzymes that catalyze posttranslational modification of proteins by Ca(2+)-dependent cross-linking reactions. The family members of TGs participate in many significant processes of biological functions such as tissue regeneration, cell differentiation, apoptosis, and certain pathologies. A novel technique for TG activity assay was developed in this study. It was based on the rapid capturing, fluorescence quenching, and fast separation of the unreacted fluorescent molecules from the macromolecular product with magnetic dextran-coated charcoal. As few as 3 ng of guinea pig liver transglutaminase (gpTG) could be detected by the method; activities of 96 TG samples could be measured within an hour. The K(m) of gpTG determined by this method for monodansylcadaverine (dansyl-CAD) and N, N-dimethylcasein was 14 and 5 muM, respectively. A typical competitive inhibition pattern of cystamine on dansyl-CAD for gpTG activity was also demonstrated. The application of this technique is not limited to the use of dansyl-CAD as the fluorescent substrate of TG; other small fluor-labeled TG substrates may substitute dansyl-CAD. Finally, this method is rapid, highly sensitive, and inexpensive. It is suitable not only for high-throughput screening of enzymes or enzyme inhibitors but also for enzyme kinetic analysis.  相似文献   

18.
Fucosyltransferase VII (FucTVII) is a very promising drug target for treatment of inflammatory skin diseases. Its activity is required for synthesis of the sialyl-Lewis X glycoepitopes on the E- and P-selectin ligands, necessary for lymphocyte migration into the skin. High-throughput screening (HTS) of large chemical libraries has become the main source of novel chemical entities for the pharmaceutical industry. The screening of very large compound collections requires the use of specialized assay techniques that minimize time and costs. We describe the development of a miniaturized scintillation proximity assay for human FucTVII based on a oligosaccharide acceptor substrate that is identical to the glycosylation of the physiological substrate. In addition to assay development, the assay performance in a HTS campaign is shown. We screened 798,131 compounds from the Schering AG HTS library and identified 233 IC50 hits; 229 hits were FucTVII specific in so far as they did not inhibit either alpha-fucosidase or galactosyltransferase. In addition to screening a drug-like small-molecule collection, we worked on rational approaches to develop inhibitors or glycosidic decoys based on oligosaccharide-substrate analogues. The structure-activity relationship observed thereby is very narrow and shows strict requirements that are consistent with the described substrate specificity of FucTVII.  相似文献   

19.
Caspases are cysteine proteases presenting a conserved active site that cleaves protein substrates at a highly specific position. They are involved in different aspects of the active cell death pathway. Most of them act through proteolytic degradations of cellular components. This paper describes the assay development, assay validation, and screening for inhibitors of this enzyme, which could be potential drug candidates. The assay uses homogeneous time-resolved fluorescence based on energy transfer from europium cryptate as donor to cross-linked allophycocyanin as acceptor (XL665). A double-tagged substrate, biotinyl-epsilon-aminocaproyl-L-aspartyl-L-glutamyl-L-valyl-Laspartyl-L-alanyl-L-propyl-N(epsilon)-(2,4-dinitrophenyl)-L-lysine-amide (biotin-X-DEVDAPK(dnp)-NH(2)), is conjugated with streptavidin cryptate and anti-dnp-XL665 monoclonal antibody. The close proximity between donor and acceptor induces a specific time-resolved fluorescence signal. In the presence of enzyme activity, the substrate cleavage induces an unlinking of the two fluorescent probes and, subsequently, the disappearance of the specific signal as a result of loss of proximity. Experiments to optimize the reagent concentration, incubation times, precision, reproducibility, and robustness are discussed in comparison with a fluorometric method.  相似文献   

20.
Recent developments in infrared laser technology have enabled the design of a compact instrumentation for two-photon excitation microparticle fluorometry (TPX). The microparticles can be used in immunoassays as the antibody-coated solid phase to capture an antigen and then detect it with a fluorescently labeled tracer antibody. Unlike most other methods, TPX technology allows low-volume, homogeneous immunoassays with real-time measurements of assay particles in the presence of a moderate excess of fluorescent tracer. In this study, the TPX assay system was used for the reagent characterization and the measurement of C-reactive protein (CRP) in diluted plasma samples, targeting the assay range useful in infectious disease diagnosis. The pentameric structure of the CRP permitted the optimization of an assay with the lowest detectable concentration of 1 microg/L (7.5 pM) by using a single monoclonal antibody both for capture and as the tracer. With a 1:200 predilution of samples, the measurement range of the assay was 1-150 mg/L, but an additional 1:10 dilution was required for higher concentrations. The TPX method showed a good correlation with the reference result obtained in a routine hospital laboratory, demonstrating the feasibility of the technology for immunodiagnostic applications.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号