首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Multiple displacement amplification (MDA) has emerged as a promising new method of whole genome amplification (WGA) with the potential to generate virtually unlimited genome-equivalent DNA from only a small amount of seed DNA. To date, genome-wide high marker density assessments of MDA–DNA have focussed mainly upon suitability for single nucleotide polymorphism (SNP) genotyping applications. Suitability for short tandem repeat (STR) genotyping has not been investigated in great detail, despite their inherent instability during DNA replication, and the obvious challenge that this presents to WGA techniques. Here, we aimed to assess the applicability of MDA in STR genotyping by conducting a genome-wide scan of 768 STR markers for MDAs of 15 high quality genomic DNAs. We found that MDA genotyping call and accuracy rates were only marginally lower than for genomic DNA. Pooling of three replicate MDAs resulted in a small increase in both call rate and genotyping accuracy. We identified 34 STRs (4.4% of total markers) of which five essentially failed with MDA samples, and 29 of which showed elevated genotyping failures/discrepancies in the MDAs. We emphasise the importance of DNA and MDA quality checks, and the use of appropriate controls to identify problematic STR markers.  相似文献   

2.
As the number of single-nucleotide polymorphism (SNP) screening and other mutation scanning studies have increased explosively, following the development of high-throughput instrumentation, it becomes even more important to have sufficient template DNA. The source of DNA is often limited, especially in epidemiological studies, which require many samples as well as enough DNA to perform numerous SNP screenings or mutation scannings. Therefore, the aim is to solve the problem of stock DNA limitation. This need has been an important reason for the development of whole genome amplification (WGA) methods. Several systems are based on Phi29 polymerase multiple displacement amplification (MDA) or on DNA fragmentation (OmniPlex). Using TaqMan SNP genotyping assays, we have tested four WGA systems -- AmpliQ Genomic Amplifier Kit, GenomiPhi, Repli-g, and GenomePlex -- on DNA extracted from Guthrie cards to evaluate the amplification bias, concordance- and call rates, cost efficiency, and flexibility. All systems successfully amplified picograms of DNA from Guthrie cards to micrograms of product without loss of heterozygosity and with minimal allelic bias. A modified AmpliQ set up was chosen for further evaluation. In all, 2,000 SNP genotyping results from amplified and nonamplified samples were compared and the concordance rates between the samples were 99.7%. The call rate using the TaqMan system was 99.8%. DNA extracted from Guthrie cards and amplified with one of the four evaluated WGA systems is applicable in epidemiological genetic screenings. System choice should be based on requirements for system flexibility, product yield, and use in subsequent analysis.  相似文献   

3.
We present a protocol for reliably detecting DNA copy number aberrations in a single human cell. Multiple displacement-amplified DNAs of a cell are hybridized to a 3,000-bacterial artificial chromosome (BAC) array and to an Affymetrix 250,000 (250K)-SNP array. Subsequent copy number calling is based on the integration of BAC probe-specific copy number probabilities that are estimated by comparing probe intensities with a single-cell whole-genome amplification (WGA) reference model for diploid chromosomes, as well as SNP copy number and loss-of-heterozygosity states estimated by hidden Markov models (HMM). All methods for detecting DNA copy number aberrations in single human cells have difficulty in confidently discriminating WGA artifacts from true genetic variants. Furthermore, some methods lack thorough validation for segmental DNA imbalance detection. Our protocol minimizes false-positive variant calling and enables uniparental isodisomy detection in single cells. Additionally, it provides quality assessment, allowing the exclusion of uninterpretable single-cell WGA samples. The protocol takes 5-7 d.  相似文献   

4.
We have developed a locus-specific DNA target preparation method for highly multiplexed single nucleotide polymorphism (SNP) genotyping called MARA (Multiplexed Anchored Runoff Amplification). The approach uses a single primer per SNP in conjunction with restriction enzyme digested, adapter-ligated human genomic DNA. Each primer is composed of common sequence at the 5′ end followed by locus-specific sequence at the 3′ end. Following a primary reaction in which locus-specific products are generated, a secondary universal amplification is carried out using a generic primer pair corresponding to the oligonucleotide and genomic DNA adapter sequences. Allele discrimination is achieved by hybridization to high-density DNA oligonucleotide arrays. Initial multiplex reactions containing either 250 primers or 750 primers across nine DNA samples demonstrated an average sample call rate of ~95% for 250- and 750-plex MARA. We have also evaluated >1000- and 4000-primer plex MARA to genotype SNPs from human chromosome 21. We have identified a subset of SNPs corresponding to a primer conversion rate of ~75%, which show an average call rate over 95% and concordance >99% across seven DNA samples. Thus, MARA may potentially improve the throughput of SNP genotyping when coupled with allele discrimination on high-density arrays by allowing levels of multiplexing during target generation that far exceed the capacity of traditional multiplex PCR.  相似文献   

5.
Whole genome amplification (WGA) procedures such as primer extension preamplification (PEP) or multiple displacement amplification (MDA) have the potential to provide an unlimited source of DNA for large-scale genetic studies. We have performed a quantitative evaluation of PEP and MDA for genotyping single nucleotide polymorphisms (SNPs) using multiplex, four-color fluorescent minisequencing in a microarray format. Forty-five SNPs were genotyped and the WGA methods were evaluated with respect to genotyping success, signal-to-noise ratios, power of genotype discrimination, yield and imbalanced amplification of alleles in the MDA product. Both PEP and MDA products provided genotyping results with a high concordance to genomic DNA. For PEP products the power of genotype discrimination was lower than for MDA due to a 2-fold lower signal-to-noise ratio. MDA products were indistinguishable from genomic DNA in all aspects studied. To obtain faithful representation of the SNP alleles at least 0.3 ng DNA should be used per MDA reaction. We conclude that the use of WGA, and MDA in particular, is a highly promising procedure for producing DNA in sufficient amounts even for genome wide SNP mapping studies.  相似文献   

6.
The Affymetrix Drug Metabolism Enzymes and Transporters (DMET) microarray is the first assay to offer a large representation of SNPs conferring genetic diversity across known pharmacokinetic markers. As a convenient and painless alternative to blood, saliva samples have been reported to work well for genotyping on the high density SNP arrays, but no reports to date have examined this application for saliva-derived DNA on the DMET platform. Genomic DNA extractions from saliva samples produced an ample quantity of genomic DNA for DMET arrays, however when human amplifiable DNA was measured, it was determined that a large percentage of this DNA was from bacteria or fungi. A mean of 37.3% human amplifiable DNA was determined for saliva-derived DNAs, which results in a significant decrease in the genotyping call rate (88.8%) when compared with blood-derived DNAs (99.1%). More interestingly, the percentage of human amplifiable DNA correlated with a higher genotyping call rate, and almost all samples with more than 31.3% human DNA produced a genotyping call rate of at least 96%. SNP genotyping results for saliva derived DNA (n = 39) illustrated a 98.7% concordance when compared with blood DNA. In conclusion, when compared with blood DNA and tested on the DMET array, saliva-derived DNA provided adequate genotyping quality with a significant lower number of SNP calls. Saliva-derived DNA does perform very well if it contains greater than 31.3% human amplifiable DNA.  相似文献   

7.
Zhou X  Temam S  Chen Z  Ye H  Mao L  Wong DT 《Human genetics》2005,118(3-4):504-507
Multiple displacement-based whole-genome DNA amplification is a promising tool to obtain sufficient DNA from small tissue specimens for various genetic analyses, such as SNP array-based analysis. Using Affymetrix 10 K and 100 K SNP mapping array, we evaluated the performance of the Phi29 DNA polymerase-based genome amplification. Greater than 99% concordance in genotyping calls were achieved between amplified and non-amplified DNAs for both arrays. By utilizing the Affymetrix GeneChip Chromosome Copy Number Tool, the allelic imbalance profiles for the advanced stage oral tongue squamous cell carcinoma (OTSCC) were generated based on 10 K and 100 K SNP mapping array results. The results from these two array platforms agree closely, but more precise allelic imbalance patterns can be revealed from the 100 K SNP mapping array data. Furthermore, our data suggested a frequent loss at 3p11–p12 for advanced stage OTSCC.  相似文献   

8.
Molecular and genetic studies of canine disease phenotypes can be limited by the amount of DNA available for analysis. New methods have been developed to amplify the genomic DNA of a species producing large quantities of DNA from small starting amounts. Whole genome amplification (WGA) of DNA is now being used in human studies, although this technique has not been applied extensively in veterinary research. We evaluated WGA of canine DNA for suitability in a range of molecular tests. DNA from 93 canine blood extracted and 18 buccal swab samples was subjected to WGA using the GenomiPhi kit (Amersham). Genomic DNA was compared with WGA product using a range of techniques, including reference strand-mediated conformation analysis, denaturing high-performance liquid chromatography analysis, microsatellite genotyping, direct DNA sequencing, and single nucleotide polymorphism allelic discrimination. All samples amplified well, giving an average yield of 3 mug of DNA from 2.5 ng of starting material. Extremely high levels of experimental reproducibility and concordance were observed between source and WGA DNA samples for all analyses used: greater than 95% for blood extracted DNA and greater than 80% for buccal swab DNA. These studies clearly demonstrate the usefulness of WGA of canine DNA as a means of increasing DNA quantities for canine studies. This technique will have major implications for future veterinary research.  相似文献   

9.
The success of genome-wide association studies has paralleled the development of efficient genotyping technologies. We describe the development of a next-generation microarray based on the new highly-efficient Affymetrix Axiom genotyping technology that we are using to genotype individuals of European ancestry from the Kaiser Permanente Research Program on Genes, Environment and Health (RPGEH). The array contains 674,517 SNPs, and provides excellent genome-wide as well as gene-based and candidate-SNP coverage. Coverage was calculated using an approach based on imputation and cross validation. Preliminary results for the first 80,301 saliva-derived DNA samples from the RPGEH demonstrate very high quality genotypes, with sample success rates above 94% and over 98% of successful samples having SNP call rates exceeding 98%. At steady state, we have produced 462 million genotypes per week for each Axiom system. The new array provides a valuable addition to the repertoire of tools for large scale genome-wide association studies.  相似文献   

10.
Impact of whole genome amplification on analysis of copy number variants   总被引:1,自引:0,他引:1  
Large-scale copy number variants (CNVs) have recently been recognized to play a role in human genome variation and disease. Approaches for analysis of CNVs in small samples such as microdissected tissues can be confounded by limited amounts of material. To facilitate analyses of such samples, whole genome amplification (WGA) techniques were developed. In this study, we explored the impact of Phi29 multiple-strand displacement amplification on detection of CNVs using oligonucleotide arrays. We extracted DNA from fresh frozen lymph node samples and used this for amplification and analysis on the Affymetrix Mapping 500k SNP array platform. We demonstrated that the WGA procedure introduces hundreds of potentially confounding CNV artifacts that can obscure detection of bona fide variants. Our analysis indicates that many artifacts are reproducible, and may correlate with proximity to chromosome ends and GC content. Pair-wise comparison of amplified products considerably reduced the number of apparent artifacts and partially restored the ability to detect real CNVs. Our results suggest WGA material may be appropriate for copy number analysis when amplified samples are compared to similarly amplified samples and that only the CNVs with the greatest significance values detected by such comparisons are likely to be representative of the unamplified samples.  相似文献   

11.
When cytobrush buccal cell samples have been collected as a genomic DNA (gDNA) source for an epidemiological study, whole genome amplification (WGA) can be critical to maintain sufficient DNA for genotyping. We evaluated REPLI-g WGA using gDNA from two paired cytobrushes (cytobush 'A' kept in a cell lysis buffer, and 'B' dried and kept at room temperature for 3 days, and frozen until DNA extraction) in a pilot study (n=21), and from 144 samples collected by mail in a breast cancer study. WGA success was assessed as the per cent completion/concordance of STR/SNP genotypes. Locus amplification bias was assessed using quantitative PCR of 23 human loci. The pilot study showed > 98% completion but low genotype concordance between cytobrush wgaDNA and paired blood gDNA (82% and 84% for cytobrushes A and B, respectively). Substantial amplification bias was observed with significantly lower human gDNA amplification from cytobrush B than A. Using cytobrush gDNA samples from the breast cancer study (n =20), an independent laboratory demonstrated that increasing template gDNA to the REPLI-g reaction improved genotype performance for 49 SNPs; however, average completion and concordance remained below 90%. To reduce genotype misclassification when cytobrush wgaDNA is used, inclusion of paired gDNA/wgaDNA and/or duplicate wgaDNA samples is critical to monitor data quality.  相似文献   

12.
Conservation and population genetic studies are sometimes hampered by insufficient quantities of high quality DNA. One potential way to overcome this problem is through the use of whole genome amplification (WGA) kits. We performed rolling circle WGA on DNA obtained from matched hair and tissue samples of North American red squirrels (Tamiasciurus hudsonicus). Following polymerase chain reaction (PCR) at four microsatellite loci, we compared genotyping success for DNA from different source tissues, both pre‐ and post‐WGA. Genotypes obtained with tissue were robust, whether or not DNA had been subjected to WGA. DNA extracted from hair produced results that were largely concordant with matched tissue samples, although amplification success was reduced and some allelic dropout was observed. WGA of hair samples resulted in a low genotyping success rate and an unacceptably high rate of allelic dropout and genotyping error. The problem was not rectified by conducting PCR of WGA hair samples in triplicate. Therefore, we conclude that WGA is only an effective method of enhancing template DNA quantity when the initial sample is from high‐yield material.  相似文献   

13.
Comparison of sample preparation methods for ChIP-chip assays   总被引:1,自引:0,他引:1  
A single chromatin immunoprecipitation (ChIP) sample does not provide enough DNA for hybridization to a genomic tiling array. A commonly used technique for amplifying the DNA obtained from ChIP assays is ligation-mediated PCR (LM-PCR). However; using this amplification method, we could not identify Oct4 binding sites on genomic tiling arrays representing 1% of the human genome (ENCODE arrays). In contrast, hybridization of a pool of 10 ChIP samples to the arrays produced reproducible binding patterns and low background signals. However the pooling method would greatly increase the number of ChIP reactions needed to analyze the entire human genome. Therefore, we have adapted the GenomePlex whole genome amplification (WGA) method for use in ChIP-chip assays; detailed ChIP and amplification protocols used for these analyses are provided as supplementary material. When applied to ENCODE arrays, the products prepared using this new method resulted in an Oct4 binding pattern similar to that from the pooled Oct4 ChIP samples. Importantly, the signal-to-noise ratio using the GenomePlex WGA method is superior to the LM-PCR amplification method.  相似文献   

14.
DNA quantity can be a hindrance in ecological and evolutionary research programmes due to a range of factors including endangered status of target organisms, available tissue type, and the impact of field conditions on preservation methods. A potential solution to low‐quantity DNA lies in whole genome amplification (WGA) techniques that can substantially increase DNA yield. To date, few studies have rigorously examined sequence bias that might result from WGA and next‐generation sequencing of nonmodel taxa. To address this knowledge deficit, we use multiple displacement amplification (MDA) and double‐digest RAD sequencing on the grey mouse lemur (Microcebus murinus) to quantify bias in genome coverage and SNP calls when compared to raw genomic DNA (gDNA). We focus our efforts in providing baseline estimates of potential bias by following manufacturer's recommendations for starting DNA quantities (>100 ng). Our results are strongly suggestive that MDA enrichment does not introduce systematic bias to genome characterization. SNP calling between samples when genotyping both de‐novo and with a reference genome are highly congruent (>98%) when specifying a minimum threshold of 20X stack depth to call genotypes. Relative genome coverage is also similar between MDA and gDNA, and allelic dropout is not observed. SNP concordance varies based on coverage threshold, with 95% concordance reached at ~12X coverage genotyping de‐novo and ~7X coverage genotyping with the reference genome. These results suggest that MDA may be a suitable solution for next‐generation molecular ecological studies when DNA quantity would otherwise be a limiting factor.  相似文献   

15.
We present a comprehensive protocol for extracting DNA from egg membranes and other internal debris recovered from the interior of blown museum bird eggs. A variety of commercially available DNA extraction methods were found to be applicable. DNA sequencing of polymerase chain reaction (PCR) products for a 176‐bp fragment of mitochondrial DNA was successful for most egg samples (> 78%) even though the amount of DNA extracted (mean = 14.71 ± 4.55 ng/µL) was significantly less than that obtained for bird skin samples (mean = 67.88 ± 4.77 ng/µL). For PCR and sequencing of snipe (Gallinago) DNA, we provide eight new primers for the ‘DNA barcode’ region of COI mtDNA. In various combinations, the primers target a range of PCR products sized from 72 bp to the full ‘barcode’ of 751 bp. Not all possible combinations were tested with archive snipe DNA, but we found a significantly better success rate of PCR amplification for a shorter 176‐bp target compared with a larger 288‐bp fragment (67% vs. 39%). Finally, we explored the feasibility of whole genome amplification (WGA) for extending the use of archive DNA in PCR and sequencing applications. Of two WGA approaches, a PCR‐based method was found to be able to amplify whole genomic DNA from archive skins and eggs from museum bird collections. After WGA, significantly more archive egg samples produced visible PCR products on agarose (56.9% before WGA vs. 79.0% after WGA). However, overall sequencing success did not improve significantly (78.8% compared with 83.0%).  相似文献   

16.
Recent developments in genotyping technologies coupled with the growing desire to characterize genome variation in Anopheles populations open the opportunity to develop more effective genotyping strategies for high‐throughput screening. A major bottleneck of this goal is nucleic acid extraction. Here, we examined the feasibility of using intact portions of a mosquito's leg as sources of template DNA for whole‐genome amplification (WGA) by primer‐extension preamplification. We used the Agena Biosciences MassARRAY® platform (formerly Sequenom) to genotype 78 SNPs for 265 WGA leg samples. We performed nucleic acid extraction on 36 mosquito carcasses and compared the genotype call concordance with their corresponding legs and observed full concordance. Using three legs instead of one improved genotyping success rates (96% vs. 89%, respectively), although this difference was not significant. We provide a proof of concept that WGA reactions can be performed directly on mosquito legs, thereby eliminating the need to extract nucleic acid. This approach is straightforward and sensitive and allows both species determination and genotyping of Anopheles mosquitoes to be performed in a high‐throughput manner. Our protocol also leaves the mosquito body intact facilitating other experimental analysis to be undertaken on the same sample. Based on our findings, this method would also be suitable for use with other insect species.  相似文献   

17.
Abstract

When cytobrush buccal cell samples have been collected as a genomic DNA (gDNA) source for an epidemiological study, whole genome amplification (WGA) can be critical to maintain sufficient DNA for genotyping. We evaluated REPLI-g? WGA using gDNA from two paired cytobrushes (cytobush ‘A’ kept in a cell lysis buffer, and ‘B’ dried and kept at room temperature for 3 days, and frozen until DNA extraction) in a pilot study (n=21), and from 144 samples collected by mail in a breast cancer study. WGA success was assessed as the per cent completion/concordance of STR/SNP genotypes. Locus amplification bias was assessed using quantitative PCR of 23 human loci. The pilot study showed > 98% completion but low genotype concordance between cytobrush wgaDNA and paired blood gDNA (82% and 84% for cytobrushes A and B, respectively). Substantial amplification bias was observed with significantly lower human gDNA amplification from cytobrush B than A. Using cytobrush gDNA samples from the breast cancer study (n =20), an independent laboratory demonstrated that increasing template gDNA to the REPLI-g reaction improved genotype performance for 49 SNPs; however, average completion and concordance remained below 90%. To reduce genotype misclassification when cytobrush wgaDNA is used, inclusion of paired gDNA/wgaDNA and/or duplicate wgaDNA samples is critical to monitor data quality.  相似文献   

18.

Background

Whole genome amplification (WGA) promises to eliminate practical molecular genetic analysis limitations associated with genomic DNA (gDNA) quantity. We evaluated the performance of multiple displacement amplification (MDA) WGA using gDNA extracted from lymphoblastoid cell lines (N = 27) with a range of starting gDNA input of 1–200 ng into the WGA reaction. Yield and composition analysis of whole genome amplified DNA (wgaDNA) was performed using three DNA quantification methods (OD, PicoGreen® and RT-PCR). Two panels of N = 15 STR (using the AmpFlSTR® Identifiler® panel) and N = 49 SNP (TaqMan®) genotyping assays were performed on each gDNA and wgaDNA sample in duplicate. gDNA and wgaDNA masses of 1, 4 and 20 ng were used in the SNP assays to evaluate the effects of DNA mass on SNP genotyping assay performance. A total of N = 6,880 STR and N = 56,448 SNP genotype attempts provided adequate power to detect differences in STR and SNP genotyping performance between gDNA and wgaDNA, and among wgaDNA produced from a range of gDNA templates inputs.

Results

The proportion of double-stranded wgaDNA and human-specific PCR amplifiable wgaDNA increased with increased gDNA input into the WGA reaction. Increased amounts of gDNA input into the WGA reaction improved wgaDNA genotyping performance. Genotype completion or genotype concordance rates of wgaDNA produced from all gDNA input levels were observed to be reduced compared to gDNA, although the reduction was not always statistically significant. Reduced wgaDNA genotyping performance was primarily due to the increased variance of allelic amplification, resulting in loss of heterozygosity or increased undetermined genotypes. MDA WGA produces wgaDNA from no template control samples; such samples exhibited substantial false-positive genotyping rates.

Conclusion

The amount of gDNA input into the MDA WGA reaction is a critical determinant of genotyping performance of wgaDNA. At least 10 ng of lymphoblastoid gDNA input into MDA WGA is required to obtain wgaDNA TaqMan® SNP assay genotyping performance equivalent to that of gDNA. Over 100 ng of lymphoblastoid gDNA input into MDA WGA is required to obtain optimal STR genotyping performance using the AmpFlSTR® Identifiler® panel from wgaDNA equivalent to that of gDNA.
  相似文献   

19.
The ability to genotype multiple loci of single cells would be of significant benefit to investigations of cellular processes such as oncogenesis, meiosis, fertilization, and embryogenesis. We report a simple two-step, single-tube protocol for whole-genome amplification (WGA) from single human cells using components of the GenomiPhi V2 DNA Amplification kit. For the first time, we demonstrate reliable generation of 4-7 microg amplified DNA from a single human cell within 4 h with a minimum amount of artifactual DNA synthesis. DNA amplified from single cells was genotyped for 13 heterozygous short tandem repeats (STRs) and 7 heterozygous single nucleotide polymorphisms (SNPs), and the genotyping results were compared with purified genomic DNA. Accuracy of genotyping (percent of single-cell amplifications genotyped accurately for any particular STR or SNP) varied from 37% to 100% (with an average of 80%) for STRs and from 89% to 100% (averaging 94%) for SNPs. We suggest that the method described in this report is suitable for WGA from single cells, the product of which can be subsequently used for many applications, such as preimplantation genetic analysis (PGD).  相似文献   

20.

Background

Genome-wide profiling of single-nucleotide polymorphisms is receiving increasing attention as a method of pre-implantation genetic diagnosis in humans and of commercial genotyping of pre-transfer embryos in cattle. However, the very small quantity of genomic DNA in biopsy material from early embryos poses daunting technical challenges. A reliable whole-genome amplification (WGA) procedure would greatly facilitate the procedure.

Results

Several PCR-based and non-PCR based WGA technologies, namely multiple displacement amplification, quasi-random primed library synthesis followed by PCR, ligation-mediated PCR, and single-primer isothermal amplification were tested in combination with different DNA extractions protocols for various quantities of genomic DNA inputs. The efficiency of each method was evaluated by comparing the genotypes obtained from 15 cultured cells (representative of an embryonic biopsy) to unamplified reference gDNA. The gDNA input, gDNA extraction method and amplification technology were all found to be critical for successful genome-wide genotyping. The selected WGA platform was then tested on embryo biopsies (n = 226), comparing their results to that of biopsies collected after birth. Although WGA inevitably leads to a random loss of information and to the introduction of erroneous genotypes, following genomic imputation the resulting genetic index of both sources of DNA were highly correlated (r = 0.99, P<0.001).

Conclusion

It is possible to generate high-quality DNA in sufficient quantities for successful genome-wide genotyping starting from an early embryo biopsy. However, imputation from parental and population genotypes is a requirement for completing and correcting genotypic data. Judicious selection of the WGA platform, careful handling of the samples and genomic imputation together, make it possible to perform extremely reliable genomic evaluations for pre-transfer embryos.

Electronic supplementary material

The online version of this article (doi:10.1186/1471-2164-15-889) contains supplementary material, which is available to authorized users.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号