首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A sensitive and specific HPLC method has been developed for the assay of vigabatrin in human plasma and urine. The assay involves derivatization with 4-chloro-7-nitrobenzofurazan, solid-phase extraction on a silica column and isocratic reversed-phase chromatography with fluorescence detection. Aspartam was used as an internal standard. The assay was linear over the concentration range of 0.2–20.0 μg/ml for plasma and 1.0–15.0 μg/ml for urine with a lower limit of detection of 0.1 μg/ml using 0.1 ml of starting volume of the sample. Both the within-day and day-to-day reproducibilities and accuracies were less than 5.46% and 1.6%, respectively. After a single oral dose of 500 mg of vigabatrin, the plasma concentration and the cumulative urinary excretion of the drug were determined.  相似文献   

2.
A simple, accurate and precise isocratic reversed-phase high-performance liquid chromatographic method was developed and validated for the determination of p-chloronitrobenzene (p-CNB) in rat plasma. A plasma sample was deproteinized with methanol containing the internal standard (p-bromonitrobenzene). The resulting methanol eluate obtained after centrifugation was filtered and injected into a high-performance liquid chromatograph (50 μl each). A column packed with 5 μm octadecylsilane (ODS) spherical particles was used with isocratic elution of methanol—water (45:55, v/v) at a flow-rate of 1.0 ml/min. The compounds were detected by ultraviolet absorbance at 280 nm. The retention times of p-CNB and the internal standard were 12.5 and 15.5 min, respectively, at a column oven temperature of 30°C. The results were linear from 0.05 to 100 μg/ml (r = 0.999), and the detection limit was 0.01 μg/ml. The relative error and the coefficient of variation on replicate assays were less than 7 and 10%, respectively, for all concentrations studied. The overall recoveries of p-CNB were between 97 and 105%. Plasma samples could be stored for up to one month at −20°C.  相似文献   

3.
A method for the determination of hexahydrophthalic acid, a metabolite of hexahydrophthalic anhydride, in human urine has been developed. The urine was worked-up by liquid—solid extraction, esterified with boron trifluoride—methanol, and analysed by capillary gas chromatography and selected-ion monitoring. Hexadeuterium-labelled hexahydrophthalic acid was used as the internal standard. The precision was 4% at 0.7 μg/ml and 5% at 0.07 μg/ml. The recovery of the acid for the overall method was 101% at 0.07 μg/ml of urine (with a coefficient of variation of 4%) and 95% at 0.7 μg/ml (coefficient of variation 2%). The limit of detection was 20 ng/ml urine.  相似文献   

4.
A sensitive stereoselective HPLC method was developed for determination of mefloquine (MFQ) enantiomers in plasma, urine and whole blood. The assay involved liquid-liquid extraction of MFQ from biological fluids with a mixture of hexane and isopropanol in the presence of sodium hydroxide and derivatization of the residue by (+)-(S)-naphthylethylisocyanate (NEIC) as chiral derivatizing reagent. Separation of the resulting diastereomers was performed on a silica normal-phase column using chloroform-hexane-methanol (25:74:1) as the mobile phase with a flow-rate of 1 ml/min. Using 200 μl of plasma or whole blood, the limit of determination was 0.2 μg/ml with UV detection for both enantiomers. The limit of determination in 500 μl of urine was 0.08 μg/ml with UV detection.  相似文献   

5.
A high-performance liquid chromatographic (HPLC) method was developed for the determination of disodium mercaptoundecahydrododecaborate (BSH) in biological fluids. Monobromobimane was used as a precolumn derivatizing agent. A stable derivative was obtained. The derivative was separated on a C18 column using reversed-phase ion-pairing chromatography and detected by a spectrophotometric detector at 373 nm. The detection limit was 200 ng/ml (0.1 ppm boron). Calibration curves were prepared for rat urine and plasma samples. The calibration curves were linear in the range of 1 μg/ml to 100 μg/ml for urine samples and 0.2 μg/ml to 50 μg/ml for plasma samples.  相似文献   

6.
A high-performance liquid chromatographic method was developed for the determination of a chemoprotective agent, 2-(allylthio)pyrazine (I), in human plasma and urine, and in rat blood and tissue homogenate using diazepam as an internal standard. The sample preparation was simple; 2.5 volumes of acetonitrile were added to the biological sample to deproteinize it. A 50–100 μl aliquot of the supernatant was injected onto a C18 reversed-phase column. The mobile phase employed was acetonitrile–water (55:45, v/v), and it was run at a flow-rate of 1.5 ml/min. The column effluent was monitored using an ultraviolet detector at 330 nm. The retention times for I and the internal standard were 4.0 and 5.1 min, respectively. The detection limits of I in human plasma and urine, and in rat tissue homogenate (including blood) were 20, 20 and 50 ng/ml, respectively. The coefficients of variation of the assay (within-day and between-day) were generally low (below 6.1%) in a concentration range from 0.02 to 10 μg/ml for human plasma and urine, and for rat tissue homogenate. No interferences from endogenous substances were found.  相似文献   

7.
A rapid, specific, sensitive and economical method has been developed and validated for the determination of grepafloxacin in human plasma and urine. The assay consisted of reversed-phase HPLC with UV detection. Plasma proteins were removed by a fast and efficient procedure that has eliminated the need for costly extraction and evaporation. For the urine samples, the only required sample preparation was dilution. Separation was achieved on a reversed-phase TSK gel column with an isocratic mobile system. The method had a quantification limit of 0.05 μg/ml in plasma and 0.5 μg/ml in urine. The coefficients of variation (C.V.) were less than 4% for within- and between-day analyses. The method was successfully applied to a pharmacokinetic study, and was proved to be simple, fast and reproducible.  相似文献   

8.
Novel prodrugs for the intracellular delivery of zidovudine monophosphate (AZTMP) have recently been designed. To investigate the bioconversion and pharmacokinetic profiles of these compounds, an analytical method for the simultaneous determination of zidovudine (AZT) and AZTMP in mouse plasma and peripheral red blood cells was developed. Mouse whole blood samples were treated with TBAHS, EDTA and NaH2PO4, and separated into plasma and red blood cell portions. Samples were processed by solid-phase extraction using Bond Elut C18 cartridges. Chromatography was performed using an Hypersil ODS column and a mobile phase of 2.9% (v/v) acetonitrile and 97.1% (v/v) phosphate buffer, pH 7.50, with UV detection at 267 nm. The average extraction recoveries of AZTMP and AZT in plasma were approximately 85% and 97% over their linear ranges of 0.05–5 μg/ml and 0.125–25 μg/ml, respectively. Extraction recoveries of AZTMP and AZT from peripheral red blood cells averaged 56 and 69% over their linear ranges of 0.125–5 μg/ml and 0.125–25 μg/ml, respectively. The accuracy of the assay was 90–100%. The intra- and inter-day variations of the assay were less than 14%. The analytical method was found to be applicable, reliable and suitable for pharmacokinetic studies.  相似文献   

9.
A column-switching, reversed-phase high-performance liquid chromatographic (HPLC) method for the determination of a new carbapenem antibiotic assay using ultraviolet detection has been developed for a new carbapenem antibiotic L-749,345 in human plasma and urine. A plasma sample is centrifuged and then injected onto an extraction column using 25 mM phosphate buffer, pH 6.5. After 3 min, using a column-switching valve, the analyte is back-flushed with 10.5% methanol–phosphate buffer for 3 min onto a Hypersil 5 μm C18 BDS 100×4.6 mm analytical column and then detected by absorbance at 300 nm. The sample preparation and HPLC conditions for the urine assay are similar, except for a longer analytical column 150×4.6 mm. The plasma assay is specific and linear from 0.125 to 50 μg/ml; the urine assay is linear from 1.25 to 100 μg/ml.  相似文献   

10.
A method is described for the measurement of 5,5-diphenylbarbituric acid in plasma using high-performance liquid chromatography with UV detection. Briefly, the compounds are separated on a C18 reversed-phase column using a mobile phase of 50 mM sodium acetate (pH 4.5) and methanol. The flow-rate is 1.0 ml/min and 25 μl are injected and detected at 215 nm. The method is specific and sensitive in the range of concentrations tested, with a limit of quantification of 0.25 μg/ml. The calibration curves are linear for concentrations between 0.25 and 10 μg/ml. Intra-day and inter-day coefficients of variation are less than 8.5 and 10.5%, respectively, over the linear range. Intra-day and inter-day bias are less than 7.0 and 8.0%, respectively. A pharmacokinetic study conducted in male Beagle dogs administered 10 mg/kg of 1,3-dimethoxymethyl-5,5-diphenylbarbituric acid or 8 mg/kg of 5,5-diphenylbarbituric acid intravenously demonstrates the utility of this method.  相似文献   

11.
Simultaneous determination of mycophenolic acid (MPA) and mycophenolate phenol glucuronide (MPAG) in plasma and urine was accomplished by isocratic HPLC with UV detection. Plasma was simply deproteinated with acetonitrile and concentrated, whereas urine was diluted prior to analysis. Linearity was observed from 0.2 to 50 μg/ml for both MPA and MPAG in plasma and from 1 to 50 μg/ml of MPA and 5 to 2000 μg/ml MPAG in urine with extraction recovery from plasma greater than 70%. Detection limits using 0.25 ml plasma were 0.080 and 0.20 μg/ml for MPA and MPAG, respectively. The method is more rapid and simple than previous assays for MPA and MPAG in biological fluids from patients.  相似文献   

12.
Venlafaxine, a second-generation antidepressant, acts by inhibition of the reuptake of presynaptic noradrenaline and serotonin. The main metabolite, O-desmethylvenlafaxine was found biologically active. For toxicological purpose, a rapid specific and accurate RP-HPLC assay was developed for the simultaneous determination of venlafaxine and O-desmethylvenlafaxine in human plasma. A linear response was observed over the concentration range 0.2–4 μg/ml. A good accuracy (<8%) was achieved for all quality controls, with intra-day and inter-day variation coefficient less than 10%. Finally, no interference was observed with other psychotic drugs encountered in acute poisoning. This rapid method (run time <10 min) was used to manage four voluntary intoxications involving venlafaxine.  相似文献   

13.
Three high-performance liquid chromatographic methods are described for the detection of the novel antifolate anticancer drug (6R)-5,10-dideaza-5,6,7,8-tetrahydrofolate (lometrexol): one with fluorometric detection and two with detection by UV absorbance. An assay for plasma lometrexol using UV detection (288 nm) and reversed-phase chromatography was developed, with a quantitation limit of 0.2 μg/ml and linearity up to 10 μg/ml. This assay was modified for measurement of lometrexol in urine, with a quantitation limit of 2 μg/ml and linearity up to 25 μg/ml. An alternative assay for plasma lometrexol using derivatization and fluorescence detection (excitation at 325 nm, emission at 450 nm) was also developed, which proved twenty-fold more sensitive (quantitation limit of 10 ng/ml) than the UV assay, and which was linear up to 250 ng/ml. The fluoremetric method requires sample oxidation with manganese dioxide prior to analysis, and uses ion-pair chromatography with tetramethylammonium hydrogensulphate as an ion-pair reagent. All assays use a similar preliminary solid-phase extraction method (recovery as assessed by UV absorption >73%), with C10-desmethylene lometrexol added for internal standardisation. Each assay is highly reproducible (inter-assay precision in each assay is <10%). Applicability of the fluorescence-based assay to lometrexol in plasma and the UV-based assay lometrexol in urine is demonstrated by pharmacokinetic studies in patients treated as part of a Phase I clinical evaluation of the drug.  相似文献   

14.
A gas chromatographic–electron capture detection (GC–ECD) method has been developed for determining Guan-Fu Base A (GFA), an experimental anti-arrhythmic, in human plasma. The method was based on one-step liquid–liquid extraction with toluene and chemical derivatization with pentafluoropropionic anhydride followed by GC–ECD. The derivatives of GFA and metoprolol (Met, internal standard) were confirmed by gas chromatography–mass spectrometry (GC–MS) to be dipentafluoropropionyl-GFA and dipentafluoropropionyl-Met. The method was linear over the concentration ranges of 0.1–20.0 and 1.0–30.0 μg/ml with the detection limit of 0.05 μg/ml at S/N=5. The intra- and inter-assay precisions were less than 6 and 10%, and accuracy 99.70±3.30 and 97.60±5.99%, respectively. The absolute recoveries were 81.88, 77.35, 80.79 and 83.85% for GFA at concentrations of 0.5, 1.0, 5.0 and 14.0 μg/ml and 88.24% for Met at 3.0 μg/ml, respectively.  相似文献   

15.
A gas chromatographic procedure was developed for the determination of methanol in small-volume whole blood samples. Samples (100–200 μl) were prepared by protein precipitation, with direct injection of the supernatant on a wide-bore capillary column. The recovery of methanol and acetonitrile (the internal standard) was approximately 90% and did not vary with sample volume. The assay was linear from 2 μg/ml (the limit of detection) through 1000 μg/ml and was highly reproducible (intra-day coefficient of variation <2.5%). Assay performance was assessed following exposure of rats to methanol. The results indicate that the present procedure is suitable for studies of methanol disposition in small rodent species.  相似文献   

16.
This paper describes a high-performance liquid chromatographic method for the assay of quinfamide and its main metabolite, 1-(dichloroacetyl)-1,2,3,4,-tetrahydro-6-quinolinol, in plasma, urine and feces. It requires 1 ml of biological fluid, an extraction using Sep-Pack cartridges and acetonitrile for drug elution. Analysis was performed on a CN column (5 μm) using water–acetonitrile–methanol (40:50:10) as a mobile phase at 269 nm. Results showed that the assay was linear in the range between 0.08 and 2.0 μg/ml. The limit of quantitation was 0.08 μg/ml. Maximum assay coefficient of variation was 14%. Recovery obtained in plasma, urine and feces ranged from 82% to 98%.  相似文献   

17.
A simple HPLC method with photodiode-array (PDA) ultraviolet detection was developed for the simultaneous determination of four active polyphenol components of hawthorn (Crataegus), chlorogenic acid, epicatechin, hyperoside and isoquercitrin, in rat plasma. Following extraction from the plasma samples with ethyl acetate–methanol (2:1, v/v), these four compounds were successfully separated using a C18 column with a gradient elution of 5 and 25% acetonitrile in 25 mM phosphate buffer (pH 2.4). The flow-rate was set at 1 ml/min and the eluent was detected at 325 nm for chlorogenic acid, 278 nm for epicatechin, and 360 nm for both hyperoside and isoquercitrin. Narignin (0.82 μg) was used as the internal standard and was detected at 278 nm. The method is linear over the studied range of 0.16–40, 0.63–160, 0.13–32 and 0.13–30 μg/ml for chlorogenic acid, epicatechin, hyperoside and isoquercitrin, respectively. The correlation coefficient for each analyte was greater than 0.995. The intra-day and inter-day precision of the analysis was better than 4 and 7%, respectively. The extraction recoveries at low to high concentration were greater than 85% for both epicatechin and chlorogenic acid, and greater than 94% for both hyperoside and isoquercitrin. The detection limits were 0.04, 0.20, 0.03 and 0.03 μg/ml for chlorogenic acid, epicatechin, hyperoside and isoquercitrin. The developed method was used to analyze the plasma concentrations of the four analytes after the intravenous administration of hawthorn polyphenol extract to rats.  相似文献   

18.
A specific and reproducible HPLC method using a Chiral-AGP column and UV detection was developed for the evaluation of the pharmacokinetic profile of oxodipine enantiomers in dog and man. Each enantiomer was determined in plasma in the concentration range 1–400 ng/ml using the internal standard calibration method with linear regression analysis. After extraction of oxodipine and the internal standard at alkaline pH with diethyl ether—n-hexane (50:50, v/v), this method permitted the determination of each enantiomer at levels down to 10 ng/ml in dog plasma and 25 ng/ml in human plasma with sufficient accuracy (relative error <11%, n = 6) and precision (coefficient of variation <16%, n = 6). The extracted plasma volume was 500 μl and after evaporation of the organic phase, the dry residue was dissolved in 100 μl of water—2-propanol; an aliquot of 80 μl was injected into the HPLC system.  相似文献   

19.
An HPLC method for the quantification of ketoprofen enantiomers in human plasma is described. Following extraction with a disposable C18 solid-phase extraction column, separation of ketoprofen enantiomers and I.S. (3,4-dimethoxy benzoic acid) was achieved using a chiral column [Chirex 3005; (R)-1-naphthylglycine 3,5-dinitrobenzoic acid] with the mobile phase, 0.02 M ammonium acetate in methanol, set at a flow-rate of 1.2 ml/min. Baseline separation of ketoprofen enantiomers and I.S., free from interferences, was achieved in less than 20 min. The calibration curves (n = 14) were linear over the concentration range of 0.16 to 5.00 μg/ml per enantiomer [mean r2 of 0.999 for both enantiomers, root mean square error were 0.015 for R(−) and 0.013 for S(+)]. The inter-day coefficient of variation for duplicate analysis of spiked samples was less than 7% and the accuracy was more than 93% over the concentration range of 0.2 to 4.0 μg/ml for individual enantiomer using 1 ml of plasma sample. This method has been applied to a pharmacokinetic study from healthy human volunteers following the administration of a ketoprofen extended release product (200 mg). This method is simple, fast and should find wide application in monitoring pharmacokinetic studies of ketoprofen.  相似文献   

20.
A sensitive, selective and efficient reversed-phase high-performance liquid chromatographic (HPLC) method is reported for the determination of furosemide in human plasma and urine. The method has a sensitivity limit of 5 ng/ml in plasma, with acceptable within- and between-day reproducibilities and good linearity (r2>0.99) over a concentration range from 0.05 to 2.00 μg/ml. The one-step extract of furosemide and the internal standard (warfarin) from acidified plasma or urine was eluted through a μBondapak C18 column with a mobile phase composed of 0.01 M potassium dihydrogenphosphate and acetonitrile (62:38, v/v) adjusted to pH 3.0. Within-day coefficients of variation (C.V.s) ranged from 1.08 to 8.63% for plasma and from 2.52 to 3.10% for urine, whereas between-day C.V.s ranged from 4.25 to 10.77% for plasma and from 5.15 to 6.81% for urine at three different concentrations. The minimum quantifiable concentration of furosemide was determined to be 5 ng/ml. The HPLC method described has the capability of rapid and reproducible measurement of low levels of furosemide in small amounts of plasma and urine. This method was utilized in bioavailability/pharmacokinetic studies for the routine monitoring of furosemide levels in adults, children and neonate patients.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号