首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Many measures aiming to assess the stability of human motion have been proposed in the literature, but still there is no commonly accepted way to define or quantify locomotor stability. Among these measures, orbital stability analysis via Floquet multipliers is still under debate. Some of the controversies concerning the use of this technique could lie in the absence of a standard implementation. The aim of this study was to analyse the influence of i) experimental measurement noise, ii) variables selected for the construction of the state space, and iii) number of analysed cycles on the outputs of orbital stability applied to walking. The analysis was performed on a 2-dimensional 5-link walking model and on a sample of 10 subjects performing long over-ground walks. Noise resulting from stereophotogrammetric and accelerometric measurement systems was simulated in the in-silico analysis. Maximum Floquet multipliers resulted to be affected by both number of analysed strides and state space composition. The effect of experimental noise was found to be slightly more potentially critical when analysing stereophotogrammetric data then when dealing with acceleration data. Experimental and model results were comparable in terms of overall trend, but a difference was found in the influence of the number of analysed cycles.  相似文献   

2.
Currently there is no commonly accepted way to define, much less quantify, locomotor stability. In engineering, "orbital stability" is defined using Floquet multipliers that quantify how purely periodic systems respond to perturbations discretely from one cycle to the next. For aperiodic systems, "local stability" is defined by local divergence exponents that quantify how the system responds to very small perturbations continuously in real time. Triaxial trunk accelerations and lower extremity sagittal plane joint angles were recorded from ten young healthy subjects as they walked for 10 min over level ground and on a motorized treadmill at the same speed. Maximum Floquet multipliers (Max FM) were computed at each percent of the gait cycle (from 0% to 100%) for each time series to quantify the orbital stability of these movements. Analyses of variance comparing Max FM values between walking conditions and correlations between Max FM values and previously published local divergence exponent results were computed. All subjects exhibited orbitally stable walking kinematics (i.e., magnitudes of Max FM < 1.0), even though these same kinematics were previously found to be locally unstable. Variations in orbital stability across the gait cycle were generally small and exhibited no systematic patterns. Walking on the treadmill led to small, but statistically significant improvements in the orbital stability of mediolateral (p = 0.040) and vertical (p = 0.038) trunk accelerations and ankle joint kinematics (p = 0.002). However, these improvements were not exhibited by all subjects (p < or = 0.012 for subject x condition interaction effects). Correlations between Max FM values and previously published local divergence exponents were inconsistent and 11 of the 12 comparisons made were not statistically significant (r2 < or = 19.8%; p > or = 0.049). Thus, the variability inherent in human walking, which manifests itself as local instability, does not substantially adversely affect the orbital stability of walking. The results of this study will allow future efforts to gain a better understanding of where the boundaries lie between locally unstable movements that remain orbitally stable and those that lead to global instability (i.e., falling).  相似文献   

3.
Many ecological systems experience periodic variability. Theoretical investigation of population and community dynamics in periodic environments has been hampered by the lack of mathematical tools relative to equilibrium systems. Here, I describe one such mathematical tool that has been rarely used in the ecological literature but has widespread use: Floquet theory. Floquet theory is the study of the stability of linear periodic systems in continuous time. Floquet exponents/multipliers are analogous to the eigenvalues of Jacobian matrices of equilibrium points. In this paper, I describe the general theory, then give examples to illustrate some of its uses: it defines fitness of structured populations, it can be used for invasion criteria in models of competition, and it can test the stability of limit cycle solutions. I also provide computer code to calculate Floquet exponents and multipliers. Electronic supplementary material  The online version of this article (doi:) contains supplementary material, which is available to authorized users.  相似文献   

4.
Peripheral sensory feedback is believed to contribute significantly to maintaining walking stability. Patients with diabetic peripheral neuropathy have a greatly increased risk of falling. Previously, we demonstrated that slower walking speeds in neuropathic patients lead to improved local dynamic stability. However, all subjects exhibited significant local instability during walking, even though no subject fell or stumbled during testing. The present study was conducted to determine if and how significant changes in peripheral sensation and walking speed affect orbital stability during walking. Trunk and lower extremity kinematics were examined from two prior experiments that compared patients with significant neuropathy to healthy controls and walking at multiple different speeds in young healthy subjects. Maximum Floquet multipliers were computed for each time series to quantify the orbital stability of these movements. All subjects exhibited orbitally stable walking kinematics, even though these same kinematics were previously shown to be locally unstable. Differences in orbital stability between neuropathic and control subjects were small and, with the exception of knee joint movements (p=0.001), not statistically significant (0.380p0.946). Differences in knee orbital stability were not mediated by differences in walking speed. This was supported by our finding that although orbital stability improved slightly with slower walking speeds, the correlations between walking speed and orbital stability were generally weak (r(2)16.7%). Thus, neuropathic patients do not gain improved orbital stability as a result of slowing down and do not experience any loss of orbital stability because of their sensory deficits.  相似文献   

5.
Measures calculated from unperturbed walking patterns, such as variability measures and maximum Floquet multipliers, are often used to study the stability of walking. However, it is unknown if, and to what extent, these measures correlate to the probability of falling.We studied whether in a simple model of human walking, i.e., a passive dynamic walker, the probability of falling could be predicted from maximum Floquet multipliers, kinematic state variability, and step time variability. We used an extended version of the basic passive dynamic walker with arced feet and a hip spring. The probability of falling was manipulated by varying the foot radius and hip spring stiffness, or varying these factors while co-varying the slope to keep step length constant.The simulation data indicated that Floquet multipliers and kinematic state variability correlated inconsistently with probability of falling. Step time variability correlated well with probability of falling, but a more consistent correlation with the probability of falling was found by calculating the variability of the log transform of the step time. Our findings speak against the use of maximum Floquet multipliers and suggest instead that variability of critical variables may be a good predictor of the probability to fall.  相似文献   

6.
Understanding how humans remain stable during challenging locomotor activities is critical to developing effective tests to diagnose patients with increased fall risk. This study determined if different continuous low-amplitude perturbations would induce specific measureable changes in measures of dynamic stability during walking. We applied continuous pseudo-random oscillations of either the visual scene or support surface in either the anterior-posterior or mediolateral directions to subjects walking in a virtual environment with speed-matched optic flow. Floquet multipliers and short-term local divergence exponents both increased (indicating greater instability) during perturbed walking. These responses were generally much stronger for body movements occurring in the same directions as the applied perturbations. Likewise, subjects were more sensitive to both visual and mechanical perturbations applied in the mediolateral direction than to those applied in the anterior-posterior direction, consistent with previous experiments and theoretical predictions. These responses were likewise consistent with subjects' anecdotal perceptions of which perturbation conditions were most challenging. Contrary to the Floquet multipliers and short-term local divergence exponents, which both increased, long-term local divergence exponents decreased during perturbed walking. However, this was consistent with specific changes in the mean log divergence curves, which indicated that subjects' movements reached their maximum local divergence limits more quickly during perturbed walking. Overall, the Floquet multipliers were less sensitive, but reflected greater specificity in their responses to the different perturbation conditions. Conversely, the short-term local divergence exponents exhibited less specificity in their responses, but were more sensitive measures of instability in general.  相似文献   

7.
Dynamic stability of passive dynamic walking on an irregular surface   总被引:1,自引:0,他引:1  
Falls that occur during walking are a significant health problem. One of the greatest impediments to solve this problem is that there is no single obviously "correct" way to quantify walking stability. While many people use variability as a proxy for stability, measures of variability do not quantify how the locomotor system responds to perturbations. The purpose of this study was to determine how changes in walking surface variability affect changes in both locomotor variability and stability. We modified an irreducibly simple model of walking to apply random perturbations that simulated walking over an irregular surface. Because the model's global basin of attraction remained fixed, increasing the amplitude of the applied perturbations directly increased the risk of falling in the model. We generated ten simulations of 300 consecutive strides of walking at each of six perturbation amplitudes ranging from zero (i.e., a smooth continuous surface) up to the maximum level the model could tolerate without falling over. Orbital stability defines how a system responds to small (i.e., "local") perturbations from one cycle to the next and was quantified by calculating the maximum Floquet multipliers for the model. Local stability defines how a system responds to similar perturbations in real time and was quantified by calculating short-term and long-term local exponential rates of divergence for the model. As perturbation amplitudes increased, no changes were seen in orbital stability (r(2)=2.43%; p=0.280) or long-term local instability (r(2)=1.0%; p=0.441). These measures essentially reflected the fact that the model never actually "fell" during any of our simulations. Conversely, the variability of the walker's kinematics increased exponentially (r(2)>or=99.6%; p<0.001) and short-term local instability increased linearly (r(2)=88.1%; p<0.001). These measures thus predicted the increased risk of falling exhibited by the model. For all simulated conditions, the walker remained orbitally stable, while exhibiting substantial local instability. This was because very small initial perturbations diverged away from the limit cycle, while larger initial perturbations converged toward the limit cycle. These results provide insight into how these different proposed measures of walking stability are related to each other and to risk of falling.  相似文献   

8.
External perturbations applied to the walking surface or visual field can challenge an individual's ability to maintain stability during walking. Accurately quantifying and predicting changes in stability during walking will further our understanding of how individuals respond to challenges encountered during daily life and guide the development of assessments and rehabilitation interventions for individuals at increased risk of falling. This study is the first to determine how orbital and local dynamic stability metrics, including maximum Floquet multipliers and local divergence exponents, change in response to continuous mediolateral visual and surface perturbations of different amplitudes. Eleven healthy individuals walked in a fully immersive virtual environment. Participants completed two 3-min walking trials each under the following nine conditions: no perturbations, surface perturbations at each of 3 amplitudes, and visual perturbations at each of 5 amplitudes. All perturbations were applied as continuous pseudo-random oscillations. During both surface and visual perturbations, individuals were significantly more orbitally and locally unstable compared to un-perturbed walking. As walking surface perturbation amplitudes increased, individuals were more orbitally (but not locally) unstable. As visual perturbation amplitudes increased, individuals were more locally (but not orbitally) unstable between lower and higher amplitudes. Overall, these dynamic stability metrics were much less sensitive to changes in perturbation amplitudes than to differences between un-perturbed and perturbed walking, or to differences between mechanical and visual perturbations. This suggests that the type of perturbation(s) applied has a far greater impact than the magnitude of those perturbations in determining the response that will be elicited.  相似文献   

9.
To facilitate stable walking, humans must generate appropriate motor patterns and effective corrective responses to perturbations. Yet most EMG analyses do not address the continuous nature of muscle activation dynamics over multiple strides. We compared muscle activation dynamics in young and older adults by defining a multivariate state space for muscle activity. Eighteen healthy older and 17 younger adults walked on a treadmill for 2 trials of 5 min each at each of 5 controlled speeds (80–120% of preferred). EMG linear envelopes of v. lateralis, b. femoris, gastrocnemius, and t. anterior of the left leg were obtained. Interstride variability, local dynamic stability (divergence exponents), and orbital stability (maximum Floquet multipliers; FM) were calculated. Both age groups exhibited similar preferred walking speeds (p=0.86). Amplitudes and variability of individual EMG linear envelopes increased with speed (p<0.01) in all muscles but gastrocnemius. Older adults also exhibited greater variability in b. femoris and t. anterior (p<0.004). When comparing continuous multivariate EMG dynamics, older adults demonstrated greater local and orbital instability of their EMG patterns (p<0.01). We also compared how muscle activation dynamics were manifested in kinematics. Local divergence exponents were strongly correlated between kinematics and EMG, independent of age and walking speed, while variability and max FM were not. These changes in EMG dynamics may be related to increased neuromotor noise associated with aging and may indicate subtle deterioration of gait function that could lead to future functional declines.  相似文献   

10.
11.
Falls pose a tremendous risk to those over 65 and most falls occur during locomotion. Older adults commonly walk slower, which many believe helps improve walking stability. While increased gait variability predicts future fall risk, increased variability is also caused by walking slower. Thus, we need to better understand how differences in age and walking speed independently affect dynamic stability during walking. We investigated if older adults improved their dynamic stability by walking slower, and how leg strength and flexibility (passive range of motion (ROM)) affected this relationship. Eighteen active healthy older and 17 healthy younger adults walked on a treadmill for 5min each at each of 5 speeds (80-120% of preferred). Local divergence exponents and maximum Floquet multipliers (FM) were calculated to quantify each subject's inherent local dynamic stability. The older subjects walked with the same preferred walking speeds as the younger subjects (p=0.860). However, these older adults still exhibited greater local divergence exponents (p<0.0001) and higher maximum FM (p<0.007) than the younger adults at all walking speeds. These older adults remained more locally unstable (p<0.04) even after adjusting for declines in both strength and ROM. In both age groups, local divergence exponents decreased at slower speeds and increased at faster speeds (p<0.0001). Maximum FM showed similar changes with speed (p<0.02). Both younger and older adults exhibited decreased instability by walking slower, in spite of increased variability. These increases in dynamic instability might be more sensitive indicators of future fall risk than changes in gait variability.  相似文献   

12.
When walking at a given speed, humans often appear to prefer gait patterns that minimize metabolic rate, thereby maximizing metabolic economy. However, recent experiments have demonstrated that humans do not maximize economy when walking downhill. The purpose of this study was to investigate whether this non-metabolically optimal behavior is the result of a trade-off between metabolic economy and gait stability. We hypothesized that humans have the ability to modulate their gait strategy to increase either metabolic economy or stability, but that increase in one measure will be accompanied by decrease in the other. Subjects walked downhill using gait strategies ranging from risky to conservative, which were either prescribed by verbal instructions or induced by the threat of perturbations. We quantified spatiotemporal gait characteristics, metabolic rate and several indicators of stability previously associated with fall risk: stride period variability; step width variability; Lyapunov exponents; Floquet multipliers; and stride period fractal index. When subjects walked using conservative gait strategies, stride periods and lengths decreased, metabolic rate increased, and anteroposterior maximum Lyapunov exponents increased, which has previously been interpreted as an indicator of decreased stability. These results do not provide clear support for the proposed trade-off between economy and stability, particularly when stability is approximated using complex metrics. However, several gait pattern changes previously linked to increased fall risk were observed when our healthy subjects walked with a conservative strategy, suggesting that these changes may be a response to, rather than a cause of, increased fall risk.  相似文献   

13.
Environmental threats, such as habitat size reduction or environmental pollution, may not cause immediate extinction of a population but shorten the expected time to extinction. We develop a method to estimate the mean time to extinction for a density-dependent population with environmental fluctuation. We first derive a formula for a stochastic differential equation model (canonical model) of a population with logistic growth with environmental and demographic stochasticities. We then study an approximate maximum likelihood (AML) estimate of three parameters (intrinsic growth rate r, carrying capacity K, and environmental stochasticity sigma(2)(e)) from a time series of population size. The AML estimate of r has a significant bias, but by adopting the Monte Carlo method, we can remove the bias very effectively (bias-corrected estimate). We can also determine the confidence interval of the parameter based on the Monte Carlo method. If the length of the time series is moderately long (with 40-50 data points), parameter estimation with the Monte Carlo sampling bias correction has a relatively small variance. However, if the time series is short (less than or equal to 10 data points), the estimate has a large variance and is not reliable. If we know the intrinsic growth rate r, however, the estimate of K and sigma(2)(e)and the mean extinction time T are reliable even if only a short time series is available. We illustrate the method using data for a freshwater fish, Japanese crucian carp (Carassius auratus subsp.) in Lake Biwa, in which the growth rate and environmental noise of crucian carp are estimated using fishery records.  相似文献   

14.
Two measures from information theory, transmitted information and channel capacity, can quantify the ability of neurons to convey stimulus-dependent information. These measures are calculated using probability functions estimated from stimulus-response data. However, these estimates are biased by response quantization, noise, and small sample sizes. Improved estimators are developed in this paper that depend on both an estimate of the sample-size bias and the noise in the data.This work was supported in part by Air Force Office of Scientific Research Grant AFOSR-ISSA-88-0073  相似文献   

15.
BACKGROUND: All fluorescence slide-based cytometry detections systems basically include the following components: (1) an excitation light source, (2) intermediate optics, and (3) a detection device consisting of a CCD camera or a PMT. The optical principles employed is slide-based systems are similar to those of confocal microscopes (CLSM). METHODS: The following tests evaluated confocal equipment performance: dichroic reflectivity, field illumination, lens performance, laser power output, spectral registration, axial resolution, PMT reliability, and system noise. RESULTS: Quality assurance tests provide a basis to determine if the equipment is operating correctly. Laser power, PMTs function, dichroic reflection, spectral registration, axial registration, system noise and sensitivity, lens performance and laser stability were tested colocalization of UV and visible peaks of a bead should be less than 210 nm. Interference contrast optics decrease fluorescence resolution. CONCLUSIONS: QA tests that assess CLSM system performance are also applicable to other slide-based systems. By utilization this type of testing approach, the subjective nature of assessing the CLSM may be eliminated. These tests serve as guidelines for other investigators to ensure that their machines are providing data that is accurate with the necessary resolution, sensitivity and precision.  相似文献   

16.
Measures that can predict risk of falling are essential for enrollment of older adults into fall prevention programs. Local and orbital stability directly quantify responses to very small perturbations and are therefore putative candidates for predicting fall risk. However, research to date is not conclusive on whether and how these measures relate to fall risk. Testing this empirically would be time consuming or may require high risk tripping experiments. Simulation studies therefore provide an important tool to initially explore potential measures to predict fall risk. This study performed simulations with a 3D dynamic walking model to explore if and how dynamic stability measures predict fall risk. The model incorporated a lateral step controller to maintain lateral stability. Neuronal noise of increasing amplitude was added to this controller to manipulate fall risk. Short-term (λ(S)(*)) local instability did predict fall risk, but long-term (λ(L)(*)) local instability and orbital stability (maxFM) did not. Additionally, λ(S)(*) was an early predictor for fall risk as it started increasing before fall risk increased. Therefore, λ(S)(*) could be a very useful tool to identify older adults whose fall risk is about to increase, so they can be enrolled in fall prevention programs before they actually fall.  相似文献   

17.
Wijsman EM  Nur N 《Human heredity》2001,51(3):145-149
The measured genotype approach can be used to estimate the variance contributions of specific candidate loci to quantitative traits of interest. We show here that both the naive estimate of measured-locus heritability, obtained by invoking infinite-sample theory, and an estimate obtained from a bias-corrected variance estimate based on finite-sample theory, produce biased estimates of heritability. We identify the sources of bias, and quantify their effects. The two sources of bias are: (1) the estimation of heritability from population samples as the ratio of two variances, and (2) the existence of sampling error. We show that neither heritability estimator is less biased (in absolute value) than the other in all situations, and the choice of an ideal estimator is therefore a function of the sample size and magnitude of the locus-specific contribution to the overall phenotypic variance. In most cases the bias is small, so that the practical implications of using either estimator are expected to be minimal.  相似文献   

18.
Evaluation of confocal microscopy system performance   总被引:3,自引:0,他引:3  
Zucker RM  Price O 《Cytometry》2001,44(4):273-294
BACKGROUND: The confocal laser scanning microscope (CLSM) has been used by scientists to visualize three-dimensional (3D) biological samples. Although this system involves lasers, electronics, optics, and microscopes, there are few published tests that can be used to assess the performance of this equipment. Usually the CLSM is assessed by subjectively evaluating a biological/histological test slide for image quality. Although there is a use for the test slide, there are many other components in the CLSM that need to be assessed. It would be useful if tests existed that produced reference values for machine performance. The aim of this research was to develop quality assurance tests to ensure that the CLSM was stable while delivering reproducible intensity measurements with excellent image quality. METHODS: Our ultimate research objective was to quantify fluorescence using a CLSM. To achieve this goal, it is essential that the CLSM be stable while delivering known parameters of performance. Using Leica TCS-SP1 and TCS-4D systems, a number of tests have been devised to evaluate equipment performance. Tests measuring dichroic reflectivity, field illumination, lens performance, laser power output, spectral registration, axial resolution, laser stability, photomultiplier tube (PMT) reliability, and system noise were either incorporated from the literature or derived in our laboratory to measure performance. These tests are also applicable to other manufacturer's systems with minor modifications. RESULTS: A preliminary report from our laboratory has addressed a number of the QA issues necessary to achieve CLSM performance. This report extends our initial work on the evaluation of CLSM system performance. Tests that were described previously have been modified and new tests involved in laser stability and sensitivity are described. The QA tests on the CLSM measured laser power, PMT function, dichroic reflection, spectral registration, axial registration, system noise and sensitivity, lens performance, and laser stability. Laser power stability varied between 3% and 30% due to various factors, which may include incompatibility of the fiber-optic polarization with laser polarization, thermal instability of the acoustical optical transmission filter (AOTF), and laser noise. The sensitivity of the system was measured using a 10-microm Spherotech bead and the PMTs were assessed with the CV concept (image noise). The maximum sensitivity obtainable on our TCS-SP1 system measured on the 10-microm Spherotech beads was approximately 4% for 488 nm, 2.5% for 568 nm, 20% for 647 nm, and 19% for 365 nm laser light. The values serve as a comparison to test machine sensitivity from the same or different manufacturers. CONCLUSIONS: QA tests are described on the CLSM to assess performance and ensure that reproducing data are obtained. It is suggested strongly that these tests be used in place of a biological/histological sample to evaluate system performance. The tests are more specific and can recognize instrument functionality and problems better than a biological/histological sample. Utilization of this testing approach will eliminate the subjective assessment of the CLSM and may allow the data from different machines to be compared. These tests are essential if one is interested in making intensity measurements on experimental samples as well as obtaining the best signal detection and image resolution from a CLSM. Published 2001 Wiley-Liss, Inc.  相似文献   

19.
This paper presents an exact analysis of a mutually coupled relay oscillator based on a method orignated by Tsypkin. Limit-cycle frequencies and phases can be determined exactly using this method, unlike other approximate methods based on describing functions and harmonic balance techniques. A new method of exact determination of limit-cycle stability is also shown to give excellent agreement with simulation studies. Different types of intercoupling are shown to give different stability conditions, and these are discussed in relation to gastrointestinal (GI) smooth muscle modelling. GI tract electrical activity has previously been modelled using bidirectionally coupled nonlinear oscillators, and the results of the present analysis of relay oscillators is compared with other studies using van der Pol dynamics.  相似文献   

20.
S R Lipsitz 《Biometrics》1992,48(1):271-281
In many empirical analyses, the response of interest is categorical with an ordinal scale attached. Many investigators prefer to formulate a linear model, assigning scores to each category of the ordinal response and treating it as continuous. When the covariates are categorical, Haber (1985, Computational Statistics and Data Analysis 3, 1-10) has developed a method to obtain maximum likelihood (ML) estimates of the parameters of the linear model using Lagrange multipliers. However, when the covariates are continuous, the only method we found in the literature is ordinary least squares (OLS), performed under the assumption of homogeneous variance. The OLS estimates are unbiased and consistent but, since variance homogeneity is violated, the OLS estimates of variance can be biased and may not be consistent. We discuss a variance estimate (White, 1980, Econometrica 48, 817-838) that is consistent for the true variance of the OLS parameter estimates. The possible bias encountered by using the naive OLS variance estimate is discussed. An estimated generalized least squares (EGLS) estimator is proposed and its efficiency relative to OLS is discussed. Finally, an empirical comparison of OLS, EGLS, and ML estimators is made.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号