1.

Objectives

During surgeries that put the visual pathway at risk of injury, continuous monitoring of the visual function is desirable. However, the intraoperative monitoring of the visual evoked potential (VEP) is not yet widely used. We evaluate here the clinical utility of intraoperative VEP monitoring.

Methods

We analyzed retrospectively 46 consecutive surgeries in 2011-2013. High luminance stimulating devices delivered flash stimuli on the closed eyelid during intravenous anesthesia. We monitored VEP features N75 and P100 and took patients'' preoperative and postoperative visual function from patient charts. Postoperative ophthalmologic workup was performed in 25 (54%) patients and preoperatively in 28 (61%) patients.

Results

VEP recordings were feasible in 62 of 85 eyes (73%) in 46 patients. All 23 eyes without VEP had impaired vision. During surgery, VEPs remained stable throughout surgery in 50 eyes. In 44 of these, visual function did not deteriorate and three patients (6 eyes) developed hemianopia. VEP decreased transiently in 10 eyes and visual function of all was preserved. VEPs were lost permanently in 2 eyes in two patients without new postoperative visual impairment.

Conclusions

Satisfactory intraoperative VEP monitoring was feasible in all patients except in those with severe visual impairment. Preservation of VEPs predicted preserved visual function. During resection of lesions in the visual cortex, VEP monitoring could not detect new major visual field defects due to injury in the posterior visual pathway. Intraoperative VEPs were sensitive enough to detect vascular damage during aneurysm clipping and mechanical manipulation of the anterior visual pathway in an early reversible stage. Intraoperative VEP monitoring influenced surgical decisions in selected patients and proved to be a useful supplement to the toolbox of intraoperative neurophysiological monitoring.  相似文献   

2.

Background

The Solitaire AB stent is one of many assistant stents used for treating wide-necked cerebral aneurysm, and has been used since 2003. However, large sample studies on its safety and effectiveness are lacking. The objective of this study was to evaluate the effectiveness and safety of the Solitaire AB stent in the coil embolization of wide-necked cerebral aneurysms.

Methods

Retrospective review of the clinical and image data of 116 patients with wide-necked cerebral aneurysms who had been enrolled at six interventional neuroradiology centers from February 2010 to February 2014 and had been treated by coil embolization; in total, 120 Solitaire AB stents were used. The degree of aneurysm occlusion was examined using digital subtraction angiography (DSA) immediately after the procedure and during follow-up, and was graded using the modified Raymond classification. We also observed complications to evaluate the safety and effectiveness of this therapy.

Results

The 120 Solitaire AB stents (4 mm × 15 mm, four stents; 4 mm × 20 mm, 16 stents; 6 mm × 20 mm, 36 stents; 6 mm × 30 mm, 64 stents) were inserted to treat 120 wide-necked cerebral aneurysms. All stents were inserted successfully. DSA immediately post-surgery revealed 55 cases of complete occlusion, 59 cases of neck remnant, and six cases of aneurysm remnant. Perioperatively, there were four cases of hemorrhage and four cases of stent thrombosis. The follow-up spanned 3–37 months; of 92 patients examined by DSA at the 6-month follow up, 12 had disease recurrence.

Conclusions

The Solitaire AB stent is effective with a good technical success rate and short-term effect for assisting coil embolization of wide-necked cerebral aneurysms.  相似文献   

3.

Background

Infective endocarditis (IE) is commonly complicated by cerebral embolization and hemorrhage secondary to intracranial mycotic aneurysms (ICMAs). These complications are associated with poor outcome and may require diagnostic and therapeutic plans to be modified. However, routine screening by brain CT and CT angiography (CTA) is not standard practice. We aimed to study the impact of routine cerebral CTA on treatment decisions for patients with IE.

Methods

From July 2007 to December 2012, we prospectively recruited 81 consecutive patients with definite left-sided IE according to modified Duke’s criteria. All patients had routine brain CTA conducted within one week of admission. All patients with ICMA underwent four-vessel conventional angiography. Invasive treatment was performed for ruptured aneurysms, aneurysms ≥5 mm, and persistent aneurysms despite appropriate therapy. Surgical clipping was performed for leaking aneurysms if not amenable to intervention. Results: The mean age was 30.43±8.8 years and 60.5% were males. Staph aureus was the most common organism (32.3%). Among the patients, 37% had underlying rheumatic heart disease, 26% had prosthetic valves, 23.5% developed IE on top of a structurally normal heart and 8.6% had underlying congenital heart disease. Brain CT/CTA revealed that 51 patients had evidence of cerebral embolization, of them 17 were clinically silent. Twenty-six patients (32%) had ICMA, of whom 15 were clinically silent. Among the patients with ICMAs, 11 underwent endovascular treatment and 2 underwent neurovascular surgery. The brain CTA findings prompted different treatment choices in 21 patients (25.6%). The choices were aneurysm treatment before cardiac surgery rather than at follow-up, valve replacement by biological valve instead of mechanical valve, and withholding anticoagulation in patients with prosthetic valve endocarditis for fear of aneurysm rupture.

Conclusions

Routine brain CT/CTA resulted in changes in the treatment plan in a significant proportion of patients with IE, even those without clinically evident neurological disease. Routine brain CT/CTA may be indicated in all hospitalized patients with IE.  相似文献   

4.

Background and Purpose

The conflicting findings of previous morphological and hemodynamic studies on intracranial aneurysm rupture may be caused by the relatively small sample sizes and the variation in location of the patient-specific aneurysm models. We aimed to determine the discriminators for aneurysm rupture status by focusing on only posterior communicating artery (PCoA) aneurysms.

Materials and Methods

In 129 PCoA aneurysms (85 ruptured, 44 unruptured), clinical, morphological and hemodynamic characteristics were compared between the ruptured and unruptured cases. Multivariate logistic regression analysis was performed to determine the discriminators for rupture status of PCoA aneurysms.

Results

While univariate analyses showed that the size of aneurysm dome, aspect ratio (AR), size ratio (SR), dome-to-neck ratio (DN), inflow angle (IA), normalized wall shear stress (NWSS) and percentage of low wall shear stress area (LSA) were significantly associated with PCoA aneurysm rupture status. With multivariate analyses, significance was only retained for higher IA (OR = 1.539, p < 0.001) and LSA (OR = 1.393, p = 0.041).

Conclusions

Hemodynamics and morphology were related to rupture status of intracranial aneurysms. Higher IA and LSA were identified as discriminators for rupture status of PCoA aneurysms.  相似文献   

5.

Background and Purpose

In recurrent cerebral aneurysms treated by coil embolization, coil compaction is regarded as the presumptive mechanism. We test the hypothesis that aneurysm growth is the primary recurrence mechanism. We also test the hypothesis that the coil mass will translate a measurable extent when recurrence occurs.

Methods

An objective, quantitative image analysis protocol was developed to determine the volumes of aneurysms and coil masses during initial and follow-up visits from 3D rotational angiograms. The population consisted of 15 recurrence and 12 non-recurrence control aneurysms initially completely coiled at a single center. An investigator sensitivity study was performed to assess the objectivity of the methods. Paired Wilcoxon tests (p<0.05, one-tailed) were performed to assess for aneurysm and coil growth. The translation of the coil mass center at follow-up was computed. A Mann Whitney U-Test (p<0.05, one-tailed) was used to compare translation of coil mass centers between recurrence and control subjects.

Results

Image analysis protocol was found to be insensitive to the investigator. Aneurysm growth was evident in the recurrence cohort (p=0.003) but not the control (p=0.136). There was no evidence of coil compaction in either the recurrence or control cohorts (recurrence: p=0.339; control: p=0.429). The translation of the coil mass centers was found to be significantly larger in the recurrence cohort than the control cohort (p=0.047).

Conclusion

Aneurysm sac growth, not coil compaction, was the primary mechanism of recurrence following successful coil embolization. The coil mass likely translates to a measurable extent when recurrence occurs and has the potential to serve as a non-angiographic recurrence marker.  相似文献   

6.

Objective

In recent years, cerebral artery stenting has become an effective method for the treatment of cerebral artery stenosis. However, methods for assessing efficacy and techniques for follow-up imaging still need to be developed. This study was designed to evaluate the application of transcranial color-coded sonography (TCCS) in assessing stenting of middle cerebral artery (MCA) stenosis. And, two new imaging techniques (vascular enhancement technology (VET) and 3-dimensional (3D) imaging) were tried out and evaluated.

Method

We enrolled 43 patients with cerebral artery stenosis for vascular stent implantation. All patients were examined by ultrasonography and confirmed through digital subtraction angiography. The stenosis was imaged and blood flow parameters were analyzed before and after the procedure using TCCS. VET and 3D imaging model were used in part of the patients. Important postoperative hemodynamic changes were noted.

Results

1) Adequate stent image was present in 41 out of 43 patients as detected by postoperative 2-dimensional imaging. Images lacking clarity were obtained in 2 patients. 2) The perioperative and postoperative (one week follow-up) instantaneous blood flow velocity at the site of stenosis was significantly decreased (P<0.05) when compared with preoperative levels. Differences between postoperative (one week follow-up) and preoperative blood flow velocity were significant (P<0.05). Differences in blood flow velocity at long-term follow-up (six months and two years) compared to one-week values were not statistically significant (P>0.05). 3) VET imaging visualizes the MCA lumen and stent morphology clearly. 3D ultrasound can be used for imaging of the stent shape as well as its inner surface.

Conclusion

TCCD can be considered a quick and effective clinical detection method to evaluate the intracranial arterial hemodynamics changes before and after stenting treatment for MCA stenosis. New imaging technologies 3D and VET can achieve additional image information.  相似文献   

7.

Background

One possible area of intervention to prevent postoperative delirium (PD) is intraoperative blood pressure management. However, the relationship between intraoperative blood pressure and PD is unclear. A secondary analysis of a RCT study examining the PD risk over the range of absolute intraoperative mean arterial blood pressure (MAP) readings and the corresponding relative changes from preoperative baseline level was performed to determine the role of MAP on PD.

Methods

Nonparametric locally weighted quadratic polynomial smoothing (LOESS) regression explored the pattern of PD risk at postoperative day 2 as a function of mean surgery MAP (msMAP) and percent change of msMAP from baseline in 103 elderly hip fracture patients. Segment-linear logistic regression models were then constructed to determine the odds ratios (OR) of PD over the observed range of these msMAP measures, adjusting for potential confounds.

Results

Twenty-three patients (22%) developed PD on day 2. LOESS regression revealed a j-shaped association between absolute levels of msMAP and PD risk. When msMAP was ≥80 mmHg, higher msMAP imparted greater PD risk (OR = 2.28 per 10 mmHg msMAP increase; 95% CI: 1.11–4.70), while higher msMAP was associated with lower PD risk (OR = 0.19 per 10 mmHg increase; CI: 0.05–0.76) if msMAP was <80 mmHg. There was no statistically significant relationship between PD risk and average percent change from baseline in these msMAP measures.

Conclusion

In elderly hip fracture patients, both very high and very low levels of msMAP were associated with significantly increased risk of PD.  相似文献   

8.

Introduction

Extracranial carotid artery aneurysms (ECAA) are rare but may be accompanied with significant morbidity. Previous studies mostly focused on diagnostic imaging and treatment. In contrast, the pathophysiological mechanisms and natural course of ECAA are largely unknown. Understanding the pathophysiological background may add to prediction of risk for adverse outcome and need for surgical exclusion. The aim of this study was to investigate the histopathological characteristics of ECAA in patients who underwent complete surgical ECAA resection.

Material and Methods

From March 2004 till June 2013, 13 patients were treated with open ECAA repair. During surgery the aneurysm sac was resected and processed for standardized histological analysis. Sections were stained with routine hematoxylin and eosin and special stains to detect elastin, collagen, different types of inflammatory cells, vascular smooth muscle cells and endothelial cells.

Results

Histopathological characterization revealed two distinct categories: dissection (abrupt interruption of the media; n = 3) and degeneration (general loss of elastin fibers in the media; n = 10). In the degenerative samples the elastin fibers in the media were fragmented and were partly absent. Inflammatory cells were observed in the vessel wall of the aneurysms.

Conclusion

Histological analysis in this small sample size revealed dissection and degeneration as the two distinct underlying mechanisms in ECAA formation.  相似文献   

9.

Purpose

To investigate the length variation of the posterior auricular artery and propose a novel classification of the posterior auricular artery based on angiographical appearance.

Patients and Methods

A series of 234 consecutive patients who had undergone conventional cerebral angiography was analyzed. The posterior auricular artery was examined on the lateral projection of the external carotid or common carotid arteriography. The posterior auricular artery was classified into four groups by length, using the external auditory canal and the top of the helix as radiographical landmarks. Our proposed classification is as follows: Type A, posterior auricular artery terminates between its origin and the center of the external auditory canal; Type B, posterior auricular artery terminates between the center of the external auditory canal and the top of the helix; Type C, posterior auricular artery terminates between the top of the helix and the vertex; and Type D, posterior auricular artery reaches up to the vertex.

Results

A total of 424 (right, 214; left, 210) posterior auricular arteries were analyzed in 111 men and 123 women aged 11 to 91 years (mean, 61.0 years) examined for aneurysms in 78 cases, occlusive vascular diseases in 56, intracranial hemorrhages in 41, tumors in 35, and others in 24. Types A, B, C, and D were found in 15.1%, 34.9%, 48.8%, and 1.2% of the patients, respectively.

Conclusion

A novel classification of the posterior auricular artery identifies four types based on its length on cerebral angiography.  相似文献   

10.

Object

Randomized trials have demonstrated a survival benefit for endovascular treatment of ruptured cerebral aneurysms. We investigated the association of surgical clipping and endovascular coiling with outcomes in subarachnoid hemorrhage (SAH) patients in a real-world regional cohort.

Methods

We performed a cohort study involving patients with ruptured cerebral aneurysms, who underwent surgical clipping, or endovascular coiling from 2009–2013 and were registered in the Statewide Planning and Research Cooperative System (SPARCS) database. An instrumental variable analysis was used to investigate the association of treatment technique with outcomes.

Results

Of the 4,098 patients undergoing treatment, 2,585 (63.1%) underwent coiling, and 1,513 (36.9%) underwent clipping. Using an instrumental variable analysis, we did not identify a difference in inpatient mortality [marginal effect (ME), -0.56; 95% CI, -1.03 to 0.02], length of stay (LOS) (ME, 1.72; 95% CI, -3.39 to 6.84), or the rate of 30-day readmissions (ME, -0.30; 95% CI, -0.82 to 0.22) between the two treatment techniques for patients with SAH. Clipping was associated with a higher rate of discharge to rehabilitation (ME, 0.63; 95% CI, 0.24 to 1.01). In sensitivity analysis, mixed effect regression, and propensity score adjusted regression models demonstrated identical results.

Conclusions

Using a comprehensive all-payer cohort of patients in New York State presenting with aneurysmal SAH we did not identify an association of treatment method with mortality, LOS or 30-day readmission. Clipping was associated with a higher rate of discharge to rehabilitation.  相似文献   

11.

Purpose

To evaluate retinal function by intraoperative electroretinograms (ERGs) before and after core vitrectomy.

Design

Retrospective consecutive case series.

Method

Full-field photopic ERGs were recorded prior to the beginning and just after core vitrectomy using a sterilized contact lens electrode in 20 eyes that underwent non-complicated vitreous surgery. A light-emitted diode was embedded into the contact lens, and a stimulus of 150 ms on and 350 ms off at 2 Hz was delivered. The amplitudes and latencies of the a-, b-, and d-waves, photopic negative response (PhNR), and oscillatory potentials (OPs) were analyzed. The intraocular temperature at the mid-vitreous was measured at the beginning and just after the surgery with a thermoprobe.

Results

The intraocular temperature was 33.2 ± 1.3°C before and 29.4 ± 1.7°C after the vitrectomy. The amplitudes of the PhNR and OPs were significantly smaller after surgery, and the latencies of all components were prolonged after the surgery. These changes were not significantly correlated with the changes of the temperature.

Conclusion

Retinal function is reduced just after core vitrectomy in conjunction with significant temperature reduction. The differences in the degree of alterations of each ERG component suggests different sensitivity of each type of retinal neuron.  相似文献   

12.

Objectives

The contribution of ultrasound-assisted thoracic paravertebral block to postoperative analgesia remains unclear. We compared the effect of a combination of ultrasound assisted-thoracic paravertebral block and propofol general anesthesia with opioid and sevoflurane general anesthesia on volatile anesthetic, propofol and opioid consumption, and postoperative pain in patients having breast cancer surgery.

Methods

Patients undergoing breast cancer surgery were randomly assigned to ultrasound-assisted paravertebral block with propofol general anesthesia (PPA group, n = 121) or fentanyl with sevoflurane general anesthesia (GA group, n = 126). Volatile anesthetic, propofol and opioid consumption, and postoperative pain intensity were compared between the groups using noninferiority and superiority tests.

Results

Patients in the PPA group required less sevoflurane than those in the GA group (median [interquartile range] of 0 [0, 0] vs. 0.4 [0.3, 0.6] minimum alveolar concentration [MAC]-hours), less intraoperative fentanyl requirements (100 [50, 100] vs. 250 [200, 300]μg,), less intense postoperative pain (median visual analog scale score 2 [1, 3.5] vs. 3 [2, 4.5]), but more propofol (median 529 [424, 672] vs. 100 [100, 130] mg). Noninferiority was detected for all four outcomes; one-tailed superiority tests for each outcome were highly significant at P<0.001 in the expected directions.

Conclusions

The combination of propofol anesthesia with ultrasound-assisted paravertebral block reduces intraoperative volatile anesthetic and opioid requirements, and results in less post operative pain in patients undergoing breast cancer surgery.

Trial Registration

ClinicalTrial.gov NCT00418457  相似文献   

13.

Purpose

In eyes with a preoperative plano refractive cylinder, it would appear that there is no rationale for astigmatic treatment. The aim of this retrospective, cross-sectional data analysis was to determine the amount of topographic astigmatism in refractive plano eyes that results in reduced efficacy after myopic laser in situ keratomileusis (LASIK).

Methods

This study included 267 eyes from 267 consecutive myopic patients with a refractive plano cylinder. Receiver operating characteristic analysis was used to find the cut-off values of preoperative ocular residual astigmatism (= topographic astigmatism) that can best discriminate between groups of efficacy and safety indices in preoperative plano refractive cylinder eyes.

Results

Preoperative ocular residual astigmatism (ORA) (or topographic astigmatism) of ≤0.9 diopters (D) resulted in an efficacy index of at least 0.8 statistically significantly more frequently than eyes with a preoperative ORA of >0.9 D. Eyes with a high ORA preoperatively also had a high ORA postoperatively. Regression analysis showed that each diopter of preoperative ORA reduced efficacy by 0.07.

Conclusion

A preoperative corneal astigmatism of ≥0.9 D could (partially) be taken into account in the LASIK design, even if the subjective refractive astigmatism is neutral.  相似文献   

14.

Background

Repetitive administration of medication or contrast agents is frequently performed in mice. The introduction of vascular access mini-ports (VAMP) for mice allows long-term vascular catheterization, hereby eliminating the need for repeated vessel puncture. With catheter occlusion being the most commonly reported complication of chronic jugular vein catheterization, we tested whether digital subtraction angiography (DSA) can be utilized to evaluate VAMP patency in mice.

Methods

Twenty-three mice underwent catheterization of the jugular vein and subcutaneous implantation of a VAMP. The VAMP was flushed every second day with 50 μL of heparinized saline solution (25 IU/ml). DSA was performed during injection of 100 μL of an iodine based contrast agent using an industrial X-ray inspection system intraoperatively, as well as 7±2 and 14±2 days post implantation.

Results

DSA allowed localization of catheter tip position, to rule out dislocation, kinking or occlusion of a microcatheter, and to evaluate parent vessel patency. In addition, we observed different ante- and retrograde collateral flow patterns in case of jugular vein occlusion. More exactly, 30% of animals showed parent vessel occlusion after 7±2 days in our setting. At this time point, nevertheless, all VAMPs verified intravascular contrast administration. After 14±2 days, intravascular contrast injection was verified in 70% of the implanted VAMPs, whereas at this point of time 5 animals had died or were sacrificed and in 2 mice parent vessel occlusion hampered intravascular contrast injection. Notably, no occlusion of the catheter itself was observed.

Conclusion

From our observations we conclude DSA to be a fast and valuable minimally invasive tool for investigation of catheter and parent vessel patency and for anatomical studies of collateral blood flow in animals as small as mice.  相似文献   

15.

Objective

In ovarian cancer, two of the most important prognostic factors for survival are completeness of staging and completeness of cytoreductive surgery. Therefore, intra-operative visualization of tumor lesions is of great importance. Preclinical data already demonstrated tumor visualization in a mouse-model using near-infrared (NIR) fluorescence imaging and indocyanine green (ICG) as a result of enhanced permeability and retention (EPR). The aim of this study was to determine feasibility of intraoperative ovarian cancer metastases imaging using NIR fluorescence imaging and ICG in a clinical setting.

Methods

Ten patients suspected of ovarian cancer scheduled for staging or cytoreductive surgery were included. Patients received 20 mg ICG intravenously after opening the abdominal cavity. The mini-FLARE NIR fluorescence imaging system was used to detect NIR fluorescent lesions.

Results

6 out of 10 patients had malignant disease of the ovary or fallopian tube, of which 2 had metastatic disease outside the pelvis. Eight metastatic lesions were detected in these 2 patients, which were all NIR fluorescent. However, 13 non-malignant lesions were also NIR fluorescent, resulting in a false-positive rate of 62%. There was no significant difference in tumor-to-background ratio between malignant and benign lesions (2.0 vs 2.0; P=0.99).

Conclusions

This is the first clinical trial demonstrating intraoperative detection of ovarian cancer metastases using NIR fluorescence imaging and ICG. Despite detection of all malignant lesions, a high false-positive rate was observed. Therefore, NIR fluorescence imaging using ICG based on the EPR effect is not satisfactory for the detection of ovarian cancer metastases. The need for tumor-specific intraoperative agents remains.

Trial Registration

ISRCTN Registry ISRCTN16945066  相似文献   

16.

Purpose

Selective Internal Radiation Therapy (SIRT) with 90yttrium (Y-90) is an increasingly used therapeutic option for unresectable liver malignancies. Nontarget embolization of extrahepatic tissue secondary to vascular shunting can lead to SIRT associated complications. Our aim was to assess whether extrahepatic shunts can reliably be diagnosed based on hepatic digital subtraction angiography (DSA) or whether subsequent SPECT/CT data can provide additional information.

Materials and Methods

825 patients with hepatocellular carcinoma (n = 636), hepatic metastases (n = 158) or cholangiocellular carcinoma (n = 31) were retrospectively analyzed. During hepatic DSA 128 arteries causing shunt flow to gastrointestinal tissue were coilembolized (right gastric artery n = 63, gastroduodenal artery n = 29; branches to duodenum / pancreas n = 36). Technectium-99m-labeled human serum albumin (HSA) was injected in all 825 patients. SPECT/CT data was used to identify additional or remaining shunts to extrahepatic tissue.

Results

An unexpected uptake of HSA in extrahepatic tissue was found by SPECT/CT in 54/825 (6.5%) patients (located in stomach n = 13, duodenum n = 26, distal bowel segments n = 12, kidney n = 1, diaphragm n = 2). These patients underwent repeated DSA and newly identified shunt vessels were coilembolized in 22/54 patients, while in 12/54 patients a more distal catheter position for repeat injection of HSA was chosen. In 20/54 patients the repeated SPECT/CT data still revealed an extrahepatic HSA uptake. These patients did not receive SIRT.

Conclusion

Most extrahepatic shunts can be identified on DSA prior to Y-90 therapy. However, SPECT-CT data helps to identify additional shunts that were initially not seen on DSA.  相似文献   

17.

Background

Mapping of the great saphenous vein is very important for planning of peripheral and coronary bypass surgery. This study investigated mapping of the great saphenous vein as an adjunct to peripheral MR angiography using a blood pool contrast agent in patients who were referred for evaluation of peripheral arterial occlusive disease and bypass surgery.

Methods

38 patients with peripheral arterial occlusive disease (21 men; mean age: 71 years, range, 44–88 years) underwent peripheral MR angiography using the blood pool contrast agent Gadofosveset trisodium. Apart from primary arterial assessment images were evaluated in order to determine great saphenous vein diameters at three levels: below the saphenofemoral junction, mid thigh and 10 cm above the knee joint (usability: diameter range: >3 and <10 mm at one level and >3.5 and <10 mm at a neighboring level). Duplex ultrasound was performed by an independent examiner providing diameter measurements at the same levels. Additionally, vessel usability was determined intraoperatively by the vascular surgeon during subsequent bypass surgery.

Results

Mean venous diameters for MR angiography/duplex ultrasound were 5.4±2.6/5.5±2.8 mm (level 1), 4.7±2.7/4.6±2.9 mm (level 2) and 4.4±2.2/4.5±2.3 mm (level 3), respectively, without significant differences between the modalities (P = 0.207/0.806/0.518). Subsequent surgery was performed in 27/38 patients. A suitable saphenous vein was diagnosed in 25 and non-usability was diagnosed in 2 of the 27 patients based on MR angiography/duplex ultrasound, respectively. Usability was confirmed by intraoperative assessment in all of the 24 patients that received a venous bypass graft in subsequent bypass surgery. In 1 case, in which the great saphenous vein was assessed as useable by both MR angiography and duplex ultrasound, it was not used during subsequent bypass surgery due to the patients clinical condition and comorbidities.

Conclusion

Simultaneous mapping of the great saphenous vein as an imaging adjunct to peripheral MR angiography with a blood pool contrast agent is an alternative to additive duplex ultrasound in patients undergoing subsequent peripheral bypass grafting.  相似文献   

18.

Aim

To evaluate the type of venous involvement in Chinese Budd-Chiari syndrome (BCS) patients and the relative diagnostic accuracy of the different imaging modalities.

Methods

Using digital subtraction angiography (DSA) as a reference standard, color Doppler ultrasound (CDUS), computed tomography angiography (CTA), and magnetic resonance angiography (MRA) were performed on 338 patients with BCS. We analyzed the course of the main and any accessory hepatic veins (HVs) and the inferior vena cava (IVC) to assess the etiology of obstructed segments and diagnostic accuracy of CDUS, CTA and MRA.

Results

Among the 338 cases, there were 8 cases (2.4%) of isolated IVC membranous obstruction, 45 cases (13.3%) of isolated HV occlusion, and 285 cases (84.3%) with both IVC membranous obstruction and HV occlusion. Comparing with DSA, CDUS, CTA had a diagnostic accuracy of 89.3% and 80.2% in detecting BCS, and 83.4% of cases correctly correlated by MRA.

Conclusion

In Henan Province, most patients with BCS have complex lesions combining IVC and HV involvement. The combination of CDUS and CTA or MRI is useful for diagnosis of BCS and guiding therapy.  相似文献   

19.

Purpose

Evaluation of peripheral retinal vascular changes in anterior uveitis using ultra-wide-field fluorescein angiography.

Design

A prospective, observational study of a case series of patients diagnosed with anterior uveitis.

Methods

Setting: Clinical observation at an academic medical center. Patient or Study Population: A total of 65 eyes of 33 patients corresponded with the research criteria of anterior uveitis in the opinion of specialists of Peking University First Hospital. Observation Procedures: Patients were diagnosed primarily through clinical examinations and conventional fluorescein angiography. Subsequently, ultra-wide-field fluorescein angiograms were obtained for each patient. Main Outcome Measures: The main outcome was the detection of peripheral retinal changes by ultra-wide-field fluorescein angiography, and how these changes influenced the evaluation and management of the disease.

Results

Peripheral vessel leakage was detected in 27 eyes (42%) with anterior uveitis, of which 15 eyes displayed active inflammation and 12 eyes displayed inactive inflammation. Peripheral vessel leakage was found in seven of eight eyes with cystoid macular edema. Cystoid macular edema was detected in 7 of 27 eyes (26%) with peripheral vessel leakage, whereas 1 of 38 eyes (3%) did not display peripheral vessel leakage (p<0.01). 44.4% of the patients with peripheral vessel leakage had a specific etiology. The relevant treatment strategies were modified based on the results of the ultra-wide-field fluorescein angiography. 12 patients with peripheral vessel leakage and a quiescent anterior segment were added to those receiving topical glucocorticoids, while 3 patients with serious peripheral vessel leakage and an active anterior segment received a sub-Tenon injection of triamcinolone acetonide.

Conclusions

Ultra-wide-field fluorescein angiography was very effective in detecting peripheral retinal vascular pathology in anterior uveitis. The changes found in the periphery were important in the evaluation and management of anterior uveitis.  相似文献   

20.

Objective

Several ultrasound-based methods are currently used to assess aortic diameter, circumferential strain and stiffness in mice, but none of them is flawless and a gold standard is lacking. We aimed to assess the validity and sensitivity of these methods in control animals and animals developing dissecting abdominal aortic aneurysm.

Methods and Results

We first compared systolic and diastolic diameters as well as local circumferential strains obtained in 47 Angiotensin II-infused ApoE -/- mice with three different techniques (BMode, short axis MMode, long axis MMode), at two different abdominal aortic locations (supraceliac and paravisceral), and at three different time points of abdominal aneurysm formation (baseline, 14 days and 28 days). We found that short axis BMode was preferred to assess diameters, but should be avoided for strains. Short axis MMode gave good results for diameters but high standard deviations for strains. Long axis MMode should be avoided for diameters, and was comparable to short axis MMode for strains. We then compared pulse wave velocity measurements using global, ultrasound-based transit time or regional, pressure-based transit time in 10 control and 20 angiotensin II-infused, anti-TGF-Beta injected C57BL/6 mice. Both transit-time methods poorly correlated and were not able to detect a significant difference in PWV between controls and aneurysms. However, a combination of invasive pressure and MMode diameter, based on radio-frequency data, detected a highly significant difference in local aortic stiffness between controls and aneurysms, with low standard deviation.

Conclusions

In small animal ultrasound the short axis view is preferred over the long axis view to measure aortic diameters, local methods are preferred over transit-time methods to measure aortic stiffness, invasive pressure-diameter data are preferred over non-invasive strains to measure local aortic stiffness, and the use of radiofrequency data improves the accuracy of diameter, strain as well as stiffness measurements.  相似文献   