首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Liquid chromatography MALDI MS/MS for membrane proteome analysis   总被引:3,自引:0,他引:3  
Membrane proteins play critical roles in many biological functions and are often the molecular targets for drug discovery. However, their analysis presents a special challenge largely due to their highly hydrophobic nature. We present a surfactant-aided shotgun proteomics approach for membrane proteome analysis. In this approach, membrane proteins were solubilized and digested in the presence of SDS followed by newly developed auto-offline liquid chromatography/matrix-assisted laser desorption ionization (LC/MALDI) tandem MS analysis. Because of high tolerance of MALDI to SDS, one-dimensional (1D) LC separation can be combined with MALDI for direct analysis of protein digests containing SDS, without the need for extensive sample cleanup. In addition, the heated droplet interface used in LC/MALDI can work with high flow LC separations, allowing a relatively large amount of protein digest to be used for 1D LC/MALDI which facilitates the detection of low abundance proteins. The proteome identification results obtained by LC/MALDI are compared to the gel electrophoresis/MS method as well as the shotgun proteomics method using 2D LC/electrospray ionization MS. It is demonstrated that, while LC/MALDI provides more extensive proteome coverage compared to the other two methods, these three methods are complementary to each other and a combination of these methods should provide a more comprehensive membrane proteome analysis.  相似文献   

2.
We demonstrate an approach for global quantitative analysis of protein mixtures using differential stable isotopic labeling of the enzyme-digested peptides combined with microbore liquid chromatography (LC) matrix-assisted laser desorption ionization (MALDI) mass spectrometry (MS). Microbore LC provides higher sample loading, compared to capillary LC, which facilitates the quantification of low abundance proteins in protein mixtures. In this work, microbore LC is combined with MALDI MS via a heated droplet interface. The compatibilities of two global peptide labeling methods (i.e., esterification to carboxylic groups and dimethylation to amine groups of peptides) with this LC-MALDI technique are evaluated. Using a quadrupole-time-of-flight mass spectrometer, MALDI spectra of the peptides in individual sample spots are obtained to determine the abundance ratio among pairs of differential isotopically labeled peptides. MS/MS spectra are subsequently obtained from the peptide pairs showing significant abundance differences to determine the sequences of selected peptides for protein identification. The peptide sequences determined from MS/MS database search are confirmed by using the overlaid fragment ion spectra generated from a pair of differentially labeled peptides. The effectiveness of this microbore LC-MALDI approach is demonstrated in the quantification and identification of peptides from a mixture of standard proteins as well as E. coli whole cell extract of known relative concentrations. It is shown that this approach provides a facile and economical means of comparing relative protein abundances from two proteome samples.  相似文献   

3.
Ongoing, worldwide efforts in genomic and protein sequencing, and the ability to readily access corresponding sequence databases, have emphatically driven the development of high‐performance bioanalytical instrumentation capable of characterizing proteins and protein–ligand interactions with great accuracy, speed and sensitivity. Two such analytical techniques have arisen over the past decade to play key roles in the characterization of proteins: surface plasmon resonance biomolecular interaction analysis (SPR‐BIA) and matrix‐assisted laser desorption/ionization time‐of‐flight mass spectrometry (MALDI‐TOF). SPR‐BIA is used in the real‐time investigation of biomolecular recognition events, and is thereby capable of providing details on the association and dissociation kinetics involved in the interaction, information ultimately leading to the determination of dissociation constants involved in the event. MALDI‐TOF is used in the structural characterization, identification and sensitive detection of biomolecules. Although the two techniques have found many independent uses in bioanalytical chemistry, the combination of the two, to form biomolecular interaction analysis mass spectrometry (BIA/MS), enables a technique of analytical capabilities greater than those of the component parts. Reviewed here are issues of concern critical to maintaining high‐levels of performance throughout the multiplexed analysis, as well as examples illustrating the potential analytical capabilities of BIA/MS. Copyright © 1999 John Wiley & Sons, Ltd.  相似文献   

4.
The peptide‐based quantitation accuracy and precision of LC‐ESI (QSTAR Elite) and LC‐MALDI (4800 MALDI TOF/TOF) were compared by analyzing identical Escherichia coli tryptic digests containing iTRAQ‐labeled peptides of defined abundances (1:1, 2.5:1, 5:1, and 10:1). Only 51.4% of QSTAR spectra were used for quantitation by ProteinPilot Software versus 66.7% of LC‐MALDI spectra. The average protein sequence coverages for LC‐ESI and LC‐MALDI were 24.0 and 18.2% (14.9 and 8.4 peptides per protein), respectively. The iTRAQ‐based expression ratios determined by ProteinPilot from the 57 467 ESI‐MS/MS and 26 085 MALDI‐MS/MS spectra were analyzed for measurement accuracy and reproducibility. When the relative abundances of peptides within a sample were increased from 1:1 to 10:1, the mean ratios calculated on both instruments differed by only 0.7–6.7% between platforms. In the 10:1 experiment, up to 64.7% of iTRAQ ratios from LC‐ESI MS/MS spectra failed S/N thresholds and were excluded from quantitation, while only 0.1% of the equivalent LC‐MALDI iTRAQ ratios were rejected. Re‐analysis of an archived LC‐MALDI sample set stored for 5 months generated 3715 MS/MS spectra for quantitation, compared with 3845 acquired originally, and the average ratios differed by only 3.1%. Overall, MS/MS‐based peptide quantitation performance of offline LC‐MALDI was comparable with on‐line LC‐ESI, which required threefold less time. However, offline LC‐MALDI allows the re‐analysis of archived HPLC‐separated samples.  相似文献   

5.
Transmissible spongiform encephalopathies (TSEs) are fatal neurodegenerative diseases that are based on the misfolding of a cellular prion protein (PrPC) into an infectious, pathological conformation (PrPSc). There is proof-of-principle evidence that a prion vaccine is possible but this is tempered with concerns of the potential dangers associated with induction of immune responses to a widely-expressed self-protein. By targeting epitopes that are specifically exposed upon protein misfolding, our group developed a vaccine that induces PrPSc-specific antibody responses. Here we consider the ability of this polyclonal antibody (SN6b) to bind to a mutant of PrPC associated with spontaneous prion disease. Polyclonal antibodies were selected to mimic the vaccination outcome and also explore all possible protein conformations of the recombinant bovine prion protein with mutation T194A [bPrP(T194A)]. This mutant is a homolog of the human T183A mutation of PrPC that is associated with early onset of familial dementia. With nanopore analysis, under non-denaturing conditions, we observed binding of the SN6b antibody to bPrP(T194A). This interaction was confirmed through ELISAs as well as immunoprecipitation of the recombinant and cellularly expressed forms of bPrP(T194A). This interaction did not promote formation of a protease resistant conformation of PrP in vitro. Collectively, these findings support the disease-specific approach for immunotherapy of prion diseases but also suggest that the concept of conformation-specific immunotherapy may be complicated in individuals who are genetically predisposed to PrPC misfolding.  相似文献   

6.
The egg yolk precursor protein, vitellogenin (Vg), was isolated by size exclusion and ion exchange chromatography from plasma of California halibut (Paralichthys californicus) treated with estrogen. MALDI TOF mass spectrometry (MS) analysis resulted in a molecular mass of 188 kDa. MS/MS de novo sequencing identified the protein as Vg by matching sequences of tryptic peptides to the known sequences of several other species. Matches were also made to two different forms of Vg in haddock, medaka, and mummichog, providing evidence that California halibut has more than one form of Vg. Native PAGE and Western blot with an antibody to turbot (Scophthalmus maximus) Vg confirmed the identity of the protein. Protein resolved on the SDS PAGE as a double band of approximately the same mass as determined with MALDI TOF, and two lower mass bands that were also immunoreactive. MALDI TOF and MS/MS de novo sequencing were useful for determining the molecular mass, identification, and exploring the multiplicity of Vg. The potential of using other MS methods to understand the structure and function of Vg is discussed.  相似文献   

7.
《朊病毒》2013,7(2):73-80
In order to obtain RNA aptamers against bovine prion protein (bPrP), we carried out in vitro selection from RNA pools containing a 55-nucleotide randomized region to target recombinant bPrP. Most of obtained aptamers contained conserved GGA tandem repeats (GGA)4 and aptamer #1 (apt #1) showed a high affinity for both bPrP and its β isoform (bPrP-β). The sequence of apt #1 suggested that it would have a G-quadruplex structure, which was confirmed using CD spectra in titration with KCl. A mutagenic study of this conserved region, and competitive assays, showed that the conserved (GGA)4 sequence is important for specific binding to bPrP and bPrP-β. Following 5′-biotinylation, aptamer #1 specifically detected PrPc in bovine brain homogenate in a Northwestern blotting assay. Protein deletion mutant analysis showed that the bPrP aptamer binds within 25-131 of the bPrP sequence. Interestingly, the minimized aptamer #1 (17nt) showed greater binding to bPrP and bPrP-β as compared to apt #1. This minimized form of aptamer #1 may therefore be useful in the detection of bPrP, diagnosis of prion disease, enrichment of bPrP, and ultimately in gaining a better understanding of prion diseases.  相似文献   

8.
《MABS-AUSTIN》2013,5(4):732-742
To monitor the Fc glycosylation of therapeutic immunoglobulin G in bioprocess development, product characterization and release analytics, reliable techniques for glycosylation analysis are needed. Several analytical methods are suitable for this application. We recently presented results comparing detection methods for glycan analysis that are separation-based, but did not include mass spectrometry (MS). In the study reported here, we comprehensively compared MS-based methods for Fc glycosylation profiling of an IgG biopharmaceutical. A therapeutic antibody reference material was analyzed 6-fold on 2 different days, and the methods investigated were compared with respect to precision, accuracy, throughput and analysis time. Emphasis was put on the detection and quantitation of sialic acid-containing glycans. Eleven MS methods were compared to hydrophilic interaction liquid chromatography of 2-aminobenzamide labeled glycans with fluorescence detection, which served as a reference method and was also used in the first part of the study. The methods compared include electrospray MS of the heavy chain and Fc part after limited digestion, liquid chromatography MS of a tryptic digest, porous graphitized carbon chromatography MS of released glycans, electrospray MS of glycopeptides, as well as matrix assisted laser desorption ionization MS of glycans and glycopeptides. Most methods showed excellent precision and accuracy. Some differences were observed with regard to the detection and quantitation of low abundant glycan species like the sialylated glycans and the amount of artefacts due to in-source decay.  相似文献   

9.
In this study, we attempted to develop a surface plasmon resonance (SPR)-based immunoassay sensor to detect alpha-fetoprotein (AFP) in human plasma at the nanogram level, as is required for clinical diagnosis of hepatocellular tumors. A self-assembled monolayer (SAM) surface of tri(ethylene glycol) (TEG) and carboxyl group-terminated hexa(ethylene glycol) (HEG) was employed to suppress the nonspecific adsorption of plasma components onto the sensor surface. AFP was detected by a sandwich-type immunoassay using two kinds of antibodies, primary and secondary, in this system. The SPR signal shift was further enhanced by applying an antibody (polyclonal) against the second antibody. With this method, the SPR signals were highly intensified, and so nanogram levels (ng/ml) of AFP could be easily detected with a high signal/noise ratio, as is necessary for clinical diagnosis. It is expected that our SPR-based immunoassay method can also be applicable to the detection of several other tumor markers that are present in low concentrations in human blood.  相似文献   

10.
The identification of proteins separated on two-dimensional gels is most commonly performed by trypsin digestion and subsequent matrix-assisted laser desorption ionization (MALDI) with time-of-flight (TOF). Recently, atmospheric pressure (AP) MALDI coupled to an ion trap (IT) has emerged as a convenient method to obtain tandem mass spectra (MS/MS) from samples on MALDI target plates. In the present work, we investigated the feasibility of using the two methodologies in line as a standard method for protein identification. In this setup, the high mass accuracy MALDI-TOF spectra are used to calibrate the peptide precursor masses in the lower mass accuracy AP-MALDI-IT MS/MS spectra. Several software tools were developed to automate the analysis process. Two sets of MALDI samples, consisting of 142 and 421 gel spots, respectively, were analyzed in a highly automated manner. In the first set, the protein identification rate increased from 61% for MALDI-TOF only to 85% for MALDI-TOF combined with AP-MALDI-IT. In the second data set the increase in protein identification rate was from 44% to 58%. AP-MALDI-IT MS/MS spectra were in general less effective than the MALDI-TOF spectra for protein identification, but the combination of the two methods clearly enhanced the confidence in protein identification.  相似文献   

11.
Solid-support based assays offer several advantages that are not normally available in solution. Enzymes that are anchored on gold surfaces can interact with several different molecules, opening the way to high throughput array format based assays. In this scenario, surface plasmon resonance (SPR) and mass spectrometry (MS) investigations have often been applied to analyze the interaction between immobilized enzyme and its substrate molecules in a tag-free environment. Here, we propose a SPR-MS combined experimental approach aimed at studying insulin degrading enzyme (IDE) immobilized onto gold surfaces and its ability to interact with insulin. The latter is delivered by a microfluidic system to the IDE functionalized surface and the activity of the immobilized enzyme is verified by atmospheric pressure/matrix assisted laser desorption ionization (AP/MALDI) MS analysis. The SPR experiments allow the calculation of the kinetic constants involved for the interaction between immobilized IDE and insulin molecules and evidence of IDE conformational change upon insulin binding is also obtained.  相似文献   

12.
Detection of Staphylococcus enterotoxin B (SEB) by biomolecular interaction analysis mass spectrometry (BIA/MS) is presented in this work. The BIA/MS experiments were based on a surface plasmon resonance (SPR) MS immunoassay that detects affinity-captured SEB both via SPR and by means of exact and direct mass measurement by matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry. Experiments were performed with standard samples and food samples to assess the BIA/MS limit of detection for SEB and to set the experimental parameters for proper quantitation. Single and double SPR referencing was performed to accurately estimate the amount of the bound toxin. Reproducible detection of 1 ng of SEB per ml, corresponding to affinity capture and MS analysis of approximately 500 amol of SEB, was readily achieved from both the standard and mushroom samples. A certain amount of SEB degradation was indicated by the signals in the mass spectra. The combination of MS with SPR-based methods of detection creates a unique approach capable of quantifying and qualitatively analyzing protein toxins from pathogenic organisms.  相似文献   

13.
Antibody-drug conjugates (ADCs) are promising biotherapeutic agents for the treatment of cancer. The careful monitoring of critical quality attributes is important for ADCs' development, manufacturing and production. In this work, the effect of the presence of a trisulfide bond in the monoclonal antibody (mAb) conjugated to DM4 cytotoxic payload through a disulfide-bond linker sulfo-SPDB (sSPDB) was investigated. Three lots of antibody containing variable levels of trisulfide bonds were used. The identity and levels of trisulfide bonds were determined by liquid chromatography/ mass spectrometry (MS)/MS analysis. The antibodies were conjugated to sSPDB-DM4 to generate ADCs. Further analysis indicated that the drug-to-antibody ratio (DAR) value, a critical quality attribute, slightly increased for the conjugates made from antibody containing higher levels of trisulfide bond. Also, higher fragmentation levels were observed in the conjugates with more trisulfide bond. Detailed characterization by MS revealed that a small amount of DM4 payload was directly attached to inter-chain cysteine residues by disulfide or trisulfide bonds. Overall, our investigation indicated that the trisulfide bond present in the mAb could react with DM4 during the conjugation process. Therefore, the presence of trisulfide bonds in the antibody moiety should be carefully monitored and well controlled during the development of a maytansinoid ADC.  相似文献   

14.
Proteomic profiling by MALDI‐TOF MS presents various advantages (speed of analysis, ease of use, relatively low cost, sensitivity, tolerance against detergents and contaminants, and possibility of automation) and is being currently used in many applications (e.g. peptide/protein identification and quantification, biomarker discovery, and imaging MS). Earlier studies by many groups indicated that moderate reproducibility in relative peptide quantification is a major limitation of MALDI‐TOF MS. In the present work, we examined and demonstrate a clear effect, in cases apparently random, of sample dilution in complex samples (urine) on the relative quantification of peptides by MALDI‐TOF MS. Results indicate that in urine relative abundance of peptides cannot be assessed with confidence based on a single MALDI‐TOF MS spectrum. To account for this issue, we developed and propose a novel method of determining the relative abundance of peptides, taking into account that peptides have individual linear quantification ranges in relation to sample dilution. We developed an algorithm that calculates the range of dilutions at which each peptide responds in a linear manner and normalizes the received peptide intensity values accordingly. This concept was successfully applied to a set of urine samples from patients diagnosed with diabetes presenting normoalbuminuria (controls) and macroalbuminuria (cases).  相似文献   

15.
Detection of Staphylococcus enterotoxin B (SEB) by biomolecular interaction analysis mass spectrometry (BIA/MS) is presented in this work. The BIA/MS experiments were based on a surface plasmon resonance (SPR) MS immunoassay that detects affinity-captured SEB both via SPR and by means of exact and direct mass measurement by matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry. Experiments were performed with standard samples and food samples to assess the BIA/MS limit of detection for SEB and to set the experimental parameters for proper quantitation. Single and double SPR referencing was performed to accurately estimate the amount of the bound toxin. Reproducible detection of 1 ng of SEB per ml, corresponding to affinity capture and MS analysis of ~500 amol of SEB, was readily achieved from both the standard and mushroom samples. A certain amount of SEB degradation was indicated by the signals in the mass spectra. The combination of MS with SPR-based methods of detection creates a unique approach capable of quantifying and qualitatively analyzing protein toxins from pathogenic organisms.  相似文献   

16.
The beneficial use of NC in MALDI‐MS has previously been reported to provide better S/N and reproducibility as well as less alkali metal adducts. We have therefore investigated if additional beneficial properties of NC also existed for commonly employed proteomics‐based LC‐MALDI procedures. Specifically we studied the effects of NC as a matrix cofactor for prestructured sample supports (AnchorChip plates), and compared the performance with several alternative sample preparation methods recently reported in the literature. The work reported here describes a new method of mixing the NC‐matrix solution with the LC‐eluent prior to sample deposition and shows that a mixture of CHCA and NC in a complex solvent offers superior analytical results in several ways: most striking is the higher signal intensity, and that the signals last much longer, due to the robustness of the matrix formulation. We have tested the use of the nitromatrix on a single LC‐MALDI preparation and found that at least ten reiterative analyses could be performed, resulting in total analysis times of more than 75 h (approximately 15 million laser shots). Consequently more than twice as many proteins could be identified than from a single analysis. This combination of longer, and stronger, MALDI signals provided an increase in the number of peptides, greater sequence coverage in MS/MS experiments and ultimately more confident peptide assignments.  相似文献   

17.
A chemiluminescent enzyme immunoassay (CLEIA) was compared to an ultraperformance liquid chromatography tandem mass spectroscopy (UPLC‐MS/MS) procedure for the analysis of zeranol and its metabolites in bovine tissue samples. Apparent recoveries from fortified samples by both methods were comparable at 0.5–4.0 µg/kg and a significant correlation was obtained. For CLEIA analysis, hapten mimicking the analyte was first synthesized and conjugated with the carrier protein bovine serum albumin as the immunogen to produce monoclonal antibody. The obtained antibody showed extensive cross‐reactivity toward zeranol metabolites (zearalanone). The limit of detection of CLEIA and UPLC‐MS/MS was 0.05 µg/kg and 0.5 µg/kg, respectively. Recoveries of both methods for fortified samples were higher than 75.0% with the coefficient of variation less than 15%. These results indicated that the combination of screening with CLEIA and confirmation with UPLC‐MS/MS for zeranol and its metabolites would be a reliable method for a large number of bovine samples. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

18.
An enzyme labeled immunosorbent assay (ELISA) and surface plasmon resonance (SPR) biosensor assay for the detection of paralytic shellfish poisoning (PSP) toxins were developed and a comparative evaluation was performed. A polyclonal antibody (BC67) used in both assay formats was raised to saxitoxin–jeffamine–BSA in New Zealand white rabbits. Each assay format was designed as an inhibition assay. Shellfish samples (n = 54) were evaluated by each method using two simple rapid extraction procedures and compared to the AOAC high performance liquid chromatography (HPLC) and the mouse bioassay (MBA). The results of each assay format were comparable with the HPLC and MBA methods and demonstrate that an antibody with high sensitivity and broad specificity to PSP toxins can be applied to different immunological techniques. The method of choice will depend on the end-users needs. The reduced manual labor and simplicity of operation of the SPR biosensor compared to ELISA, ease of sample extraction and superior real time semi-quantitative analysis are key features that could make this technology applicable in a high-throughput monitoring unit.  相似文献   

19.
Matrix‐assisted laser desorption/ionization time‐of‐flight mass spectrometry (MALDI‐TOF MS) has emerged as a promising tool to rapidly characterize Staphylococcus aureus. Different protocols have been employed, but effects of experimental factors, such as culture condition and sample preparation, on spectrum quality and reproducibility have not been rigorously examined. We applied MALDI‐TOF MS to characterize a model system consisting of five methicillin‐sensitive (MSSA) and five methicillin‐resistant S. aureus isolates (MRSA) under two culture conditions (agar and broth) and using two sample preparation methods [intact cell method and protein extraction method (PEM)]. The effects of these treatments on spectrum quality and reproducibility were quantified. PEM facilitated increases in the number of peaks and mass range width. Broth cultures further improved spectrum quality in terms of increasing the number of peaks. In addition, PEM increased reproducibility in samples prepared using identical culture conditions. MALDI imaging data suggested that the improvement in reproducibility may result from a more homogeneous distribution of sample associated with the broth/PEM treatment. Broth/PEM treatment also yielded the highest rate (96%) of correct classification for MRSA. Taken together, these results suggest that broth/PEM maximizes the performance of MALDI‐TOF MS to characterize S. aureus.

Significance and Impact of the Study

Two culture conditions (agar or broth) and two sample preparation methods (intact cell or protein extraction) were evaluated for their effects on profiling of Staphylococcus aureus using matrix‐assisted laser desorption/ionization time‐of‐flight mass spectrometry (MALDI‐TOF MS). Results indicated that MALDI‐enabled profiling of S. aureus is most effective when cultures are grown in broth and processed using a protein extraction‐based approach. These findings should enhance future efforts to maximize the performance of this approach to characterize strains of S. aureus.  相似文献   

20.
Ticks and fleas are vectors for numerous human and animal pathogens. Controlling them, which is important in combating such diseases, requires accurate identification, to distinguish between vector and non‐vector species. Recently, matrix‐assisted laser desorption/ionization time‐of‐flight mass spectrometry (MALDI‐TOF‐MS) was applied to the rapid identification of arthropods. The growth of this promising tool, however, requires guidelines to be established. To this end, standardization protocols were applied to species of Rhipicephalus sanguineus (Ixodida: Ixodidae) Latreille and Ctenocephalides felis felis (Siphonaptera: Pulicidae) Bouché, including the automation of sample homogenization using two homogenizer devices, and varied sample preservation modes for a period of 1–6 months. The MS spectra were then compared with those obtained from manual pestle grinding, the standard homogenization method. Both automated methods generated intense, reproducible MS spectra from fresh specimens. Frozen storage methods appeared to represent the best preservation mode, for up to 6 months, while storage in ethanol is also possible, with some caveats for tick specimens. Carnoy's buffer, however, was shown to be less compatible with MS analysis for the purpose of identifying ticks or fleas. These standard protocols for MALDI‐TOF MS arthropod identification should be complemented by additional MS spectrum quality controls, to generalize their use in monitoring arthropods of medical interest.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号