首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 20 毫秒
1.
Good results have been obtained with use of the new bonded chiral stationary phase Whelk-O 1 in analytical and preparative subcritical fluid chromatography. A wide variety of enantiomeric pairs of compounds with different functional groups that are of pharmaceutical and biological interest have been resolved. This Pirkle-concept CSP appears to be more rugged than cellulosic phases (e.g., Chiralcel) with regards to solvents and pressure. In comparing the usefulness of the column for SFC versus HPLC chiral analysis, we have observed a clear superiority of SFC in terms of higher speed and efficiency of analysis, and faster method development. This is consistent with our experience with Chiralcel CSPs. With the Whelk-O 1 we have shown that the effects of temperature and modifier on SFC separations are similar to what has been reported for most other CSPs. We also observed a unique selectivity advantage of SFC for verapamil. We had good success with using a 1-in. diameter column packed with Whelk-O 1 to perform preparative SFC separations of a number of enantiomeric mixtures. The advantages of preparative SFC over preparative HPLC will be discussed. The feasibility of preparative SFC is dependent on how well we meet the practical challenges such as sample introduction issues, special hardware requirements due to the high pressure, and fraction collection issues. © 1994 Wiley-Liss, Inc.  相似文献   

2.
Geiser F  Shah R 《Chirality》2004,16(4):263-266
Most HPLC enantioseparations of amine analytes are performed using normal-phase systems containing mobile phases of heptane with ethanol (or 2-propanol) and an amine additive. Since salt-forms of amine analytes are usually insoluble in normal-phase eluents, free-base forms are synthesized for preparative chromatography. It would be highly desirable to directly chromatograph salt forms of amine analytes using mobile phases of carbon dioxide (CO(2)) and methanol (MeOH). Such separations would be readily suitable for preparative chromatography, since most amine salts are highly soluble in MeOH. In this article, advantages are shown for the use of supercritical fluid chromatography (SFC) instrumentation with tandem UV and polarimetric detection for confirming enantioseparation as well as for determining optimum preparative column injections. Examples are shown for racemic mixtures of propranolol HCl (I), thioridazine HCl (II), tramadol HCl (III), and flurbiprofen (IV), all of which resolved on Chiralpak AD-H chiral stationary phase using mobile-phase systems of CO(2) and MeOH without the use of basic or acidic additives.  相似文献   

3.
The combination of the simulated moving bed (SMB) technique with supercritical fluid chromatography (SFC) leads to a process with unique features. Besides the known advantages of the SMB process, the use of supercritical carbon dioxide as the mobile phase offers the advantages of reduction in organic solvents and an easy eluent/solute separation. Because of the low viscosity and high diffusion coefficients of supercritical fluids, a high efficiency is possible. The steps of process development for SMB SFC are presented using the separations of the bi-naphthol enantiomers and phytol isomers as examples. The development of a packed column SFC method at an analytical scale is shown for the separation of the bi-naphthol enantiomers on a chiral stationary phase and CO(2) with a modifier as the mobile phase. The influence of the modifier, modifier content, and column configuration on productivity of the SMB SFC process was investigated by simulation. The first set of experiments was performed in the SMB separation of phytol isomers at low concentration to test the feasibility of the SMB SFC high purity separation of the binary mixtures. In the second set of experiments, the productivity of the process was increased by increasing the feed concentration up to 54 grams feed per liter stationary phase (SP) and hour (g(feed)/l(SP) h).  相似文献   

4.
A tool for improved tandem column chiral supercritical fluid chromatography (SFC) method development screening was prepared by modification of a commercial analytical SFC instrument with two different software-controllable, six position high-pressure column selection valves, each controlling a bank of five different columns and a pass through line. The resulting instrument, which has the ability to screen 10 different individual columns and 25 different tandem column arrangements, is a useful tool for facilitating the screening of tandem column SFC arrangements for separation of complex mixtures of stereoisomers or other multicomponent mixtures. Strategies for optimal use of the instrument are discussed, and several examples of the use of the instrument in developing tandem SFC methods for resolution of multicomponent mixtures are presented.  相似文献   

5.
All naturally occurring sphingomyelins have the d-erythro-(2S,3R) configuration of the sphingoid base. We have developed a normal-phase HPLC method for the separation of this natural stereoisomer from the l-threo-sphingomyelin, which is the other stereoisomer commonly present in semisynthetic preparations of acyl-chain defined sphingomyelins. The chromatographic method was developed by modification of a previously reported method for phospholipid separation on a normal-phase diol column. The separation was accomplished by a binary gradient of solvent mixtures (A) hexane:isopropanol:acetic acid (82:17:1.0 by vol) and (B) isopropanol:water:acetic acid (85:14:1.0 by vol) with 0.08 vol% triethylamine added to both solvent mixtures. The program of gradient elution was optimized for maximal separation of sphingomyelin diastereomers. For detection of the lipids, a light-scattering detector was used. This analytical scale HPLC method was also used for purification of the stereoisomers (up to 0.5 mg of N-oleoyl-sphingomyelin in a single injection). The purified stereoisomers were at least 99% pure according to high-performance thin-layer chromatography and analytical HPLC.  相似文献   

6.
The enantiomeric separation of several compounds, including an antifungal drug and several of its precursors, using HPLC and SFC is described in this work. The columns employed were based on polysaccharide derivatives and the results show that most of the separations obtained by SFC are better, in terms of high resolution and short analysis time, than those obtained by HPLC. Only one compound could not be resolved using SFC but, in this case, HPLC provided baseline resolution.  相似文献   

7.
Lavison G  Thiébaut D 《Chirality》2003,15(7):630-636
A stationary phase derived from ristocetin was evaluated for chiral separation in subcritical fluid chromatography. Separation of various enantiomers having different structures and pK(a) values were investigated using carbon dioxide and polar modifiers. The influence of modifiers, additives, temperature, and mobile phase flow rate on separations is presented. It is concluded that this stationary phase can be used for SFC despite its structural similarity with protein-derived stationary phases that can only be used in HPLC. The separation mechanisms could not be elucidated or predicted using these initial experiments. The separations of warfarin and, especially, efavirenz demonstrate the potential of this type of stationary phase for rapid SFC chiral separations.  相似文献   

8.
Packed column SFC is used to resolve the enantiomers of two nonsteroidal antiinflammatories. A Chiralpak AD column is used with a binary mobile phase of carbon dioxide/methanol to achieve resolution. The effects of composition, pressure, temperature, and flow on ibuprofen enantiomer separation are examined. In this instance, temperature affords the greatest change in resolution followed by pressure and composition. Baseline resolution of ibuprofen is achieved in less than 7 min and fluibiprofen is baseline resolved in less than 4 min. © 1994 Wiley-Liss, Inc.  相似文献   

9.
A novel reversed-phase (RP-) HPLC gradient profile applicable to multidimensional separations of complex protein mixtures is reported. This gradient profile elutes small numbers of proteins from the RP-HPLC column in discrete intervals while minimizing the amount of band broadening between elution intervals and maintaining constant flow through the HPLC column. Eluting the proteins in discrete intervals eases the instrumental requirements necessary for performing multidimensional separations and can be used to aid in the collection of well-defined fractions. The saw-tooth gradient was applied to the successful isolation of albumin from less abundant proteins in whole human serum and provides adequate separation of proteins in a low-molecular weight (LMW) fraction of human serum with resolution comparable to that achieved using a typical linear gradient profile.  相似文献   

10.
Separations of five diastereoisomers of nucleoside phosphoramidate derivatives (pronucleotides) were performed by both HPLC method using derivatized cellulose and amylose chiral stationary phases and CE method using anionic cyclodextrins added in the background electrolyte (BGE). An optimal baseline separation (Rs > 1.5) was readily obtained with all silica-based celluloses and amyloses using in a normal-phase methodology. Capillary electrophoresis was used as an alternative technique to HPLC for the separation of pronucleotides. The diastereoisomers were fully resolved with sulfated cyclodextrins at both BGE pH (2.5 and 6.2). Limits of detection and limits of quantification, calculated for both methods, are up to 200 times higher in CE separations than in HPLC separations. The analytical HPLC method was then applied in a preliminary study for the pronucleotide 1 quantification in cellular extract.  相似文献   

11.
This article describes a very useful extension of an unique column switching technique called "Simulated Moving Columns" (SMC) that was previously reported for chiral high performance liquid chromatography (HPLC) (Zhang and McConnell, Journal of Chromatography A 2004;1028:227-238). SMC uses two or three short chiral columns connected in series, and enables the unresolved enantiomers to separate repeatedly and exclusively through each of the columns until sufficient resolution is attained. The technique is significantly enhanced through the use of supercritical fluid chromatography (SFC). The supercritical or near critical carbon dioxide (CO(2)) used in the mobile phase of SFC possesses the properties of a liquid as well as a gas, and usually results in much sharper peaks compared to HPLC. Consequently, by combining SMC with SFC (SMC-SFC), we were able to dramatically increase the number of SMC cycles with significantly less band broadening compared to HPLC. For the first time, an enantioselective SFC separation was demonstrated by increasing the column from the actual 20 cm length to reach a half meter virtual length with remarkably enhanced efficiency. Off-column band broadening resulting from a two-column SMC system was measured, and its impact on the enantioselectivity of SMC-SFC was found to be much less than in SMC-HPLC.  相似文献   

12.
Perfluorooctane sulfonate (PFOS) is one of the most frequently detected perfluoroalkyl substances in environmental and human samples. Previous studies have shown that nonracemic PFOS in biological samples can be used as a marker of PFOS exposure sources. In recent years, supercritical fluid chromatography (SFC) has emerged as a powerful method to separate chiral compounds. In this study, a method of perfluoro‐1‐methylheptane sulfonate (1 m‐PFOS) enantioseparation by SFC was established. The optimal separation was obtained using a Chiralpak QN‐AX column with CO2/2‐propanol (70/30, v/v) as the mobile phase with a flow rate of 1 mL/min, column temperature was 32°C, and BPR pressure was 1800 psi. The resolution (Rs) and retention time were 0.88 and 130 minutes, respectively. This method is more economic and greener than HPLC. Modifier pH and column temperature were determined to be significant factors of SFC chiral separation. Modifier pH is negatively correlated with the retention factors and Rs. Adsorption thermodynamics were used to explain the influence of temperature change, and it was concluded that the transfer of two enantiomers from the mobile phase to the stationary phase is enthalpy‐driven. Enantioseparation of 1 m‐PFOS by SFC follows the same rules of ion exchange as those for the chiral separation by HPLC.  相似文献   

13.
High-performance liquid chromatographic methods were developed for the separation of the enantiomers of 12 beta-lactams. Direct separations were performed on chiral stationary phases (CSPs) containing cellulose-tris-3,5-dimethylphenyl carbamate (Chiralcel OD-RH and OD-H columns), the macrocyclic glycopeptide antibiotic teicoplanin (Chirobiotic T column), or teicoplanin aglycone (Chirobiotic TAG column) as the chiral selector. It was clearly established that, with teicoplanin-based columns, the teicoplanin aglycone was most often responsible for the enantioseparation of the beta-lactams. The difference in enantioselective free energy between the aglycone CSP and the teicoplanin CSP was in the range between 0.02 and 0.97 kJ mol(-1) for these beta-lactam stereoisomer separations. The separations were carried out with high selectivity and resolution, and the method was therefore suitable for monitoring of the enantiomeric excess after chiral synthesis. The Chirobiotic and Chiralcel columns appear to be highly complementary to one another. The best separation of this class of beta-lactam compound could be obtained using the Chirobiotic TAG in the polar-organic mode plus the Chiralcel OD-H in the normal-phase mode. The elution sequence was also determined.  相似文献   

14.
B. H. Brown  S. J. Neill  R. Horgan 《Planta》1986,167(3):421-423
Deuterium-labelled indole-3-acetic acid, abscisic acid and phthalimido-1-aminocyclopropane-1-carboxylic acid were found to separate from the unlabelled compounds on reverse-phase high-performance liquid chromatography (HPLC). A similar separation was found for the methyl esters of these compounds on normal-phase HPLC. Such separations may lead to substantial errors when these compounds are used as internal standards for quantitation by gas chromatography-mass spectrometry/selective ion detection, unless the complete chromatographic peaks are collected.Abbreviations ABA abscisic acid - ACC 1-aminocyclopropane-1-carboxylic acid - IAA indole-3-acetic acid - GC-MS gas chromatography-mass spectrometry - HPLC high-performance liquid chromatography - Pht-ACC phthalimido-ACC - SIM selected ion monitoring  相似文献   

15.
The enantiomeric separations of three neonicotinoid insecticides (identified as compounds 1 , 2 , and 3 ) were performed on three polysaccharide‐type chiral columns, that is, Chiralcel OD‐H, Chiralpak AD‐H, and Chiralpak IB, by high‐performance liquid chromatography (HPLC) and supercritical fluid chromatography (SFC). Effects of the modifier percentage and column temperature on chiral recognitions of chiral stationary phases were also studied. Both 1 and 2 could be resolved on all three columns selected, with the highest Rs values obtained on Chiralpak AD‐H and Chiralcel OD‐H, respectively. However, satisfactory separation of the four stereoisomers of 3 was only achieved on Chiralcel OD‐H. Considering the effects of ethanol on the values of k, α, and Rs, we concluded that hydrogen bonding, π–π, and/or dipole–dipole interactions might be all responsible for the chiral separation. In comparison to HPLC, a shorter run time was achieved for 1 and 2 by SFC. However, 3 could not be stereoselectively resolved using SFC. On the basis of the calculated thermodynamic parameters, we found that the separation processes of enantiomers of 1 and 2 were entropy controlled and enthalpy controlled, respectively. Chirality, 2011. © 2010 Wiley‐Liss, Inc.  相似文献   

16.
Large-scale resolution of racemic monastrol has been carried out by normal-phase mode HPLC on an amylose-based chiral stationary phase. Because monastrol solubility, in media of proper compositions for normal-mode HPLC separations (in terms of retention factors and selectivity), was significantly low and impractical for preparative scopes, racemic monastrol was transformed into the corresponding O-tert-butyldimethylsilyl derivative. The tert-butyldimethylsilyl group was chosen as a suitable derivatizing agent because it induced approximatively a six-times higher solubility and allowed for an almost quantitative recovery of pure monastrol from the derivatization-deprotection sequence. The competitive isotherms of the O-tert-butyldimethylsilyl compounds, measured through frontal analysis, were fitted to competitive Langmuir and four-parameter bi-Langmuir models. The equilibrium dispersive model of chromatography was used for modeling the nonlinear separation of the racemate and to optimize the experimental conditions for collection of highly concentrated fractions of pure (R,S)-O-tert-butyldimethylsilyl compounds, from which significant amounts of the corresponding enantiomers of monastrol (about 100 mg of each enantiomer with 30 runs on an analytical-scale column) were obtained by quantitative back-derivatization.  相似文献   

17.
As an important intermediate of prostaglandins and entecavir, optically pure Corey lactone diol (CLD) has great value in the pharmaceutical industry. In this work, the enantioseparation of (±)‐CLD was evaluated using high‐performance liquid (HPLC) and supercritical fluid chromatography (SFC). In HPLC, the separations of CLD enantiomers on polysaccharide‐based chiral stationary phases with both normal phase and polar organic phase were screened. And the conditions for the enantioseparation were optimized in HPLC and SFC, including the selection of mobile phase, temperature, back‐pressure, and other conditions. More important, it was found that the chiral resolutions were greatly enhanced by the increase of the coating amount of ADMPC (amylose tris‐(3,5‐dimethylphenylcarbamate)) under both HPLC and SFC conditions, which can lead to the increase of the productivity and the decrease of the solvent consumption. The preparations of optically pure CLD were evaluated on a semi‐preparative (2 × 25 cm) column packed with 30% ADMPC‐coated CSP under HPLC and SFC conditions. Preparative performances in terms of kkd are 1.536 kg racemate/kg CSP/day and 1.248 kg racemate/kg CSP/day in HPLC and SFC, respectively.  相似文献   

18.
In this work, monolithic columns were used as a fast separation tool for multiple-component quantitative liquid chromatography-tandem mass spectrometry (LC-MS-MS) assays of drug candidates in biological fluids. A considerably reduced runtime was achieved while maintaining good chromatographic separations. This significantly improved separation speed demanded higher throughput on sample extraction. To this end, monolithic separations were coupled on-line with high-flow extraction, which allowed for the fast extraction and separation of samples containing multiple analytes. An evaluation of this system was performed using a mixture of fenfluramine, temazepam, oxazepam, and tamoxifen in plasma. A total cycle time of 1.2 min was achieved which included both sample extraction and subsequent monolithic column separation via column switching. A total of over 400 plasma samples were analyzed in less than 10 h. The sensitivity and responses were reproducible throughout the run. The system has been routinely used in the authors' laboratory for high-throughput quantitation of compounds in biological fluids in support of drug discovery programs. The assay for samples from a 9-in-1 dog pharmacokinetic study is shown as an example to demonstrate the capability of this system.  相似文献   

19.
Very great advances have been made in the field of direct optical resolution of organic compounds by chromatographic techniques. Chiral capillary gas chromatography now permits a determination of the enantiomeric composition of a few nanograms of a compound present in a mixture of many others. Coupled with high resolution mass spectrometry the technique will additionally permit structural elucidation; of great interest in pheromone research and related areas. Analytical separations of enantiomers are now also carried out by high-performance liquid chromatography (HPLC) methods based on a variety of principles. Basically, two main types are used, differing as to whether the mobile phase has to be a chiral medium or not. Two-dimensional HPLC, whereby compounds separated on a non-chiral column are progressively and automatically transferred to a chiral column for optical resolution, has been used successsfully for chiral amino acid separations. Many different chiral sorbents for preparative LC and HPLC resolutions have been prepared; some of these are now used in columns capable of producing pure enantiomers from a given racemate at a rate of the order of one gram/hour in continuous, automatic HPLC procedures. Apart from all important applications of these results of optical resolution technology, an increased knowledge of the underlying chiral recognition phenomena responsible for enantioselection has also been achieved.  相似文献   

20.
A simple and robust LC-MS-based methodology for the investigation of lipid mixtures is described, and its application to the analysis of human lipoprotein-associated lipids is demonstrated. After an optional initial fractionation on Silica 60, normal-phase HPLC-MS on a YMC PVA-Sil column is used first for class separation, followed by reversed-phase LC-MS or LC-tandem mass spectrometry using an Atlantis dC18 capillary column, and/or nanospray MS, to fully characterize the individual lipids. The methodology is applied here for the analysis of human apolipoprotein B-associated lipids. This approach allows for the determination of even low percentages of lipids of each molecular species and showed clear differences between lipids associated with apolipoprotein B-100-LDL isolated from a normal individual and those associated with a truncated version, apolipoprotein B-67-containing lipoproteins, isolated from a homozygote patient with familial hypobetalipoproteinemia. The methods described should be easily adaptable to most modern MS instrumentation.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号