首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 203 毫秒
1.
We present the principle of cell characterization and separation by dielectrophoretic field-flow fractionation and show preliminary experimental results. The operational device takes the form of a thin chamber in which the bottom wall supports an array of microelectrodes. By applying appropriate AC voltage signals to these electrodes, dielectrophoretic forces are generated to levitate cells suspended in the chamber and to affect their equilibrium heights. A laminar flow profile is established in the chamber so that fluid flows faster with increasing distance from the chamber walls. A cell carried in the flow stream will attain an equilibrium height, and a corresponding velocity, based on the balance of dielectrophoretic, gravitational, and hydrodynamic lift forces it experiences. We describe a theoretical model for this system and show that the cell velocity is a function of the mean fluid velocity, the voltage and frequency of the signals applied to the electrodes, and, most significantly, the cell dielectric properties. The validity of the model is demonstrated with human leukemia (HL-60) cells subjected to a parallel electrode array, and application of the device to separating HL-60 cells from peripheral blood mononuclear cells is shown.  相似文献   

2.
A system of ultrasonic filter device consisted of an ultrasonic generator, ultrasonic cell separation chamber (resonator) and a guide column, which was developed for suspension cultures of a plant cell. The key operation parameters affecting the efficiency of separation of cells from medium fluid were found to be the voltage of ultrasonic generator, the convective flow rate, and the distance between transducer and reflector. In the high density cultures ofAloe saponaria (>17 g DCW/L), the ultrasonic filter was so efficient that the cell holding time in the separation chamber was 10-fold higher than the case without ultrasonic wave at a convective flow rate of 0.24 cm/min. Furthermore, in perfusion type of high cell density cultures, cell aggregates were observed to be densely held in the ultrasonic chamber by ultrasonic force overcoming both gravitational and drag forces by pump. The accumulated cells were finally overflowed after the holding capacity of the chamber was reached. Back pressure was applied periodically to the resonator to flush cells back to bioreactor. The ultrasonic cell separator could operate over 75 min at a convective flow rate of 0.1 cm/min and at a cell concentration of 17 g DCW/L.  相似文献   

3.
Dielectrophoresis, an electrokinetic migration of particles, can occur in non-uniform alternating electric fields and is dependent upon the dielectric nature of the cells and their suspending medium. An enumeration system utilising this phenomenon is described, which has the potential to count particles selectively, including different bacterial or eukaryotic cell species and even sub-populations of different cell viability states or sizes. Relationships were observed between suspension concentrations and the extent of dielectrophoretic (DEP) collection for polystyrene latex beads, pure bacterial samples and mixtures of bacterial species including Escherichia coli, Serratia marcescens, Pseudomonas aeruginosa and Bacillus subtilis. A similar relationship was utilised for polystyrene latex as a calibration line to enable the concentration of particles in a suspension to be determined according to the level of DEP collection. The particle concentration of an unknown test sample was found to lie within the predicted concentration range determined on the basis of DEP collection. In addition, the predicted limits were found only to deviate between -6.2 and +6.9% from the mean particle concentration.  相似文献   

4.
Dielectrophoretic (DEP) forces have been used extensively to manipulate, separate, and localize biological cells and bioparticles via high-gradient electric fields. However, minimization of DEP exposure time is desirable, because of possible untoward effects on cell behavior. Toward this goal, this article investigates the geometric and material determinants of particle patterning kinetics and efficiency. In particular, the time required to achieve a steady-state pattern is theoretically modeled and experimentally validated for a planar, interdigitated bar electrode array energized in a standing-wave configuration. This measure of patterning efficiency is calculated from an improved Fourier series solution of DEP force, in which realistic boundary conditions and a finite chamber height are imposed to reflect typical microfluidic applications. The chamber height, electrode spacing, and fluid viscosity and conductivity are parameters that profoundly affect patterning efficiency, and optimization can reduce electric field exposure by orders of magnitude. Modeling strategies are generalizable to arbitrary electrode design as well as to conditions where DEP force may not act alone to cause particle motion. This improved understanding of DEP patterning kinetics provides a framework for new advances in the development of DEP-based biological devices and assays with minimal perturbation of cell behavior.  相似文献   

5.
The differential analysis of human leukocytes has many important biological and medical applications. In this work, dielectrophoretic field-flow-fractionation (DEP-FFF), a cell-separation technique that exploits the differences in the density and dielectric properties of cells, was used to separate the mixtures of the major human leukocyte subpopulations (T- and B-lymphocytes, monocytes, and granulocytes). The separation was conducted in a thin chamber equipped with an array of microfabricated interdigitated electrodes on the bottom surface, and the separation performance was characterized by on-line flow cytometry. To investigate optimal separation conditions for different leukocyte mixtures, elution fractograms at various DEP field frequencies were obtained for each leukocyte subtype. With appropriately chosen conditions, high separation performance was achieved in separating T- (or B-) lymphocytes from monocytes, T- (or B-) lymphocytes from granulocytes, and monocytes from granulocytes. DEP-FFF does not involve cell-labeling or cell-modification step, and provides a new approach to hematological analysis.  相似文献   

6.
Laboratory protocols using magnetic beads have gained importance in the purification of mRNA for vaccines. Here, the produced mRNA hybridizes specifically to oligo(dT)‐functionalized magnetic beads after cell lysis. The mRNA‐loaded magnetic beads can be selectively separated using a magnet. Subsequently, impurities are removed by washing steps and the mRNA is eluted. Magnetic separation is utilized in each step, using different buffers such as the lysis/binding buffer. To reduce the time required for purification of larger amounts of mRNA vaccine for clinical trials, high‐gradient magnetic separation (HGMS) is suitable. Thereby, magnetic beads are selectively retained in a flow‐through separation chamber. To meet the requirements of biopharmaceutical production, a disposable HGMS separation chamber with a certified material (United States Pharmacopeia Class VI) was developed which can be manufactured using 3D printing. Due to the special design, the filter matrix itself is not in contact with the product. The separation chamber was tested with suspensions of oligo(dT)‐functionalized Dynabeads MyOne loaded with synthetic mRNA. At a concentration of cB = 1.6–2.1 g·L–1 in lysis/binding buffer, these 1 μm magnetic particles are retained to more than 99.39% at volumetric flows of up to 150 mL·min–1 with the developed SU‐HGMS separation chamber. When using the separation chamber with volumetric flow rates below 50 mL·min–1, the retained particle mass is even more than 99.99%.  相似文献   

7.
Dielectrophoresis (DEP) and electrorotation (ROT) are two electrokinetic phenomena exploiting nonuniform electric fields to exert a force or torque on biological particles suspended in liquid media. They are widely used in lab-on-chip devices for the manipulation, trapping, separation, and characterization of cells, microorganisms, and other particles. The DEP force and ROT torque depend on the respective polarizabilities of the particle and medium, which in turn depend on their dielectric properties and on the field frequency. In this work, we present a new software, MyDEP, which implements several particle models based on concentric shells with adjustable dielectric properties. This tool enables the study of the variation in DEP and ROT spectra according to different parameters, such as the field frequency and medium conductivity. Such predictions of particle behavior are very useful for choosing appropriate parameters in DEP experiments. The software also enables the study of the homogenized properties of spherical or ellipsoidal multishell particles and provides a database containing published cell properties. Equivalent electrical conductivity and relative permittivity of the cell alone and in suspension can be calculated. The software also offers the ability to create graphs of the evolution of the crossover frequencies with the electric field frequency. These graphs can be directly exported from the software.  相似文献   

8.
We analyze the dynamics of a spherical scaffold in rotating bioreactors (or clinostats). The idealized clinostat environment consists of a purely rotational flow that is perpendicular to a gravitational field. We confirm through a detailed analytical study that lift effects considerably alter the position of the equilibrium point reached by the scaffolds in the (vertical) direction collinear to the gravitational field. This result holds for small particle and shear Reynolds numbers. Our analysis shows that the inertial lift effect is negligible in the horizontal direction. We show that for all rotations of practical interest, and for the range of particle Reynolds number smaller than unity, the vertical coordinate of the equilibrium point is strongly affected by consideration of lift effects. For light (heavy) particles, inclusion of lift in the formation forces the equilibrium position to be below (above) the horizontal plane that contains the axis of rotation. The equilibrium point for light particles is stable and therefore is observable experimentally. The equilibrium point for heavy particles is unstable. We also estimate the stress level applied to the scaffold and derive an algebraic expression that indicates that the stress level acting on the scaffold decreases with increasing shear Reynolds number.  相似文献   

9.
The capture of 200 nm biotinylated latex beads from suspensions of concentration 10(7) to 2.5 x 10(8) particle/ml on an immuno-coated surface of the acoustic reflector in an ultrasound standing wave (USW) resonator has been studied while the acoustic pathlength was less than one half wavelength (lambda/2). The particles were delivered to the reflector's surface by acoustically induced flow. The capture dependencies on suspension concentration, duration of experiments and acoustic pressure have been established at 1.09, 1.46 and 1.75 MHz. Five-fold capture increase has been obtained at 1.75 MHz in comparison to the control (no ultrasound) situation. The contrasting behaviours of 1, 0.5 and 0.2 mum fluorescent latex beads in a lambda/4 USW resonator at 1.46 MHz have been characterized. The particle movements were observed with an epi-fluorescent microscope and the velocities of the particles were measured by particle image velocimetry (PIV). The experiments showed that whereas the trajectories of 1 mum particles were mainly affected by the direct radiation force, 0.5 mum particles were influenced both by the radiation force and acoustic streaming. The 0.2 mum latex beads followed acoustic streaming in the chamber and were not detectably affected by the radiation force. The streaming-associated behaviour of the 200 nm particles has implications for enhanced immunocapture of viruses and macromolecules (both of which are also too small to experience significant acoustic radiation force).  相似文献   

10.
SUMMARY. 1. A flow tank was constructed which generates homogeneous and stable flow of water up lo velocities of 1.2 m s−1.
2 A sensitive, two-component balance with its platform inserted in the bottom of the flume allowed the measurement of drag and lift forces in the mN range.
3 The drag forces experienced by several benthic arthropods, which cling to the roughened surface of the platform, are proportional to the square of the flow velocity.
4 Large biological variations in lift forces, leading even to negative lifts in some cases, are indications of special adaptations of the animals to counter the danger of being swept away from their support.  相似文献   

11.
We have developed an integrated laser trap/flow control video microscope for mechanical manipulation of single biopolymers. The instrument is automated to maximize experimental throughput. A single-beam optical trap capable of trapping micron-scale polystyrene beads in the middle of a 200-microm-deep microchamber is used, making it possible to insert a micropipette inside this chamber to hold a second bead by suction. Together, these beads function as easily exchangeable surfaces between which macromolecules of interest can be attached. A computer-controlled flow system is used to exchange the liquid in the chamber and to establish a flow rate with high precision. The flow and the optical trap can be used to exert forces on the beads, the displacements of which can be measured either by video microscopy or by laser deflection. To test the performance of this instrument, individual biotinylated DNA molecules were assembled between two streptavidin beads, and the DNA elasticity was characterized using both laser trap and flow forces. DNA extension under varying forces was measured by video microscopy. The combination of the flow system and video microscopy is a versatile design that is particularly useful for the study of systems susceptible to laser-induced damage. This capability was demonstrated by following the translocation of transcribing RNA polymerase up to 650 s.  相似文献   

12.
13.
Human red blood cells were treated in different ways to alter their membrane deformability, and the hydrodynamic behavior of these altered cells was studied using the steric field-flow fractionation (FFF) technique. The relationships between cell retention in the FFF channel, flow-rate of the carrier fluid and the applied field strength were studied for normal and glutaraldehyde-fixed human red cells, and separation conditions were optimized. The effect of flow-induced hydrodynamic lift forces on red cell retention in the steric FFF channel was studied, and the results suggest that the membrane deformability of the red cell is an important factor contributing to the lift force, besides other previously described effects due to density and flow velocity. Using steric FFF, a mixture of normal and glutaraldehyde-fixed human red cells was completely separated with a resolution twice that found in published d ata from gel permeation, another hydrodynamic separation technique. Partial loss of membrane deformability, induced by different degrees of glutaraldehyde-fixation, by diamide, or by a thermal treatment, has also been studied. Steric FFF is thus shown to have potential for rapid separation and differentiation of red cells with different density and membrane deformability, conditions known to be associated with, e.g., cell senescence and certain hematological diseases.  相似文献   

14.
This paper analyzes numerical simulations of the trajectories of magnetic beads in a microchannel, with a nearby permanent cubical magnet, under different flow and magnetic conditions. Analytically derived local fluid velocities and local magnetic forces have been used to track the particles. A centered position and a lateral position of the magnet above the microchannel are considered. The computed fractions of deposited particles on the walls are compared successfully with a new theoretically derived criterion that imposes a relation between the sizes of the magnet and the microchannel and the particle Stokes and Alfvén numbers to obtain the complete deposition of the flowing particles on the wall. In the cases in which all the particles, initially distributed uniformly across the section of the microchannel, are deposited on the walls, the simulations predict the accumulation of the major part of particles on the wall closest to the magnet and near the first half of the streamwise length of the magnet.  相似文献   

15.
In this study, a rapid immunosensing system has been developed for simultaneous analysis of two tumor markers, alpha-fetoprotein (AFP) and prostate-specific antigen (PSA). The strategy for rapid multisensing is based on rapid immunoreactions occurring on the surface of microparticles and the spatial separation of different particles that exhibit distinct dielectrophoretic (DEP) properties. Recognition events for immunoreactions have been performed on the surfaces of two different microparticles conjugated with two different antibodies: polystyrene (PS) microparticles with an anti-AFP antibody and gold-coated (50 nm) PS microparticles with an anti-PSA antibody. The DEP devices consisted of an upper indium tin oxide (ITO) glass and a lower ITO electrode with a castellated structure. Sandwich structured immunocomplexes of AFP and PSA were created on the microparticles and then labeled with fluorescent molecules via a secondary antibody. After introducing the particles into the DEP devices, an alternating current (AC) voltage (20 V peak-to-peak voltage and 30 kHz) was applied between the upper ITO and lower electrodes to manipulate the particles with negative dielectrophoresis (n-DEP).The uncoated PS particles and the gold-coated PS particles rapidly moved and separated to form wave-like line and triangular aggregates, respectively. The measurements of the fluorescence signals from the uncoated and gold-coated PS particles directed to different regions of the DEP device permit the determination of the concentrations of AFP and PSA simultaneously. No cross-reactivity was observed for either of the immunorecognition events. Limits of detection achieved for the AFP and PSA assays were 0.18 and 1.1 ng mL(-1), respectively, which satisfy medical requirements for both antigens in human serum. The total assay time required for the simultaneous detection of the two different analytes in this study (25 min) was shortened compared to the conventional enzyme-linked immunosorbent assay.  相似文献   

16.
The vertebrate embryonic heart first forms as a valveless tube that pumps blood using waves of contraction. As the heart develops, the atrium and ventricle bulge out from the heart tube, and valves begin to form through the expansion of the endocardial cushions. As a result of changes in geometry, conduction velocities, and material properties of the heart wall, the fluid dynamics and resulting spatial patterns of shear stress and transmural pressure change dramatically. Recent work suggests that these transitions are significant because fluid forces acting on the cardiac walls, as well as the activity of myocardial cells that drive the flow, are necessary for correct chamber and valve morphogenesis. In this article, computational fluid dynamics was used to explore how spatial distributions of the normal forces acting on the heart wall change as the endocardial cushions grow and as the cardiac wall increases in stiffness. The immersed boundary method was used to simulate the fluid-moving boundary problem of the cardiac wall driving the motion of the blood in a simplified model of a two-dimensional heart. The normal forces acting on the heart walls increased during the period of one atrial contraction because inertial forces are negligible and the ventricular walls must be stretched during filling. Furthermore, the force required to fill the ventricle increased as the stiffness of the ventricular wall was increased. Increased endocardial cushion height also drastically increased the force necessary to contract the ventricle. Finally, flow in the moving boundary model was compared to flow through immobile rigid chambers, and the forces acting normal to the walls were substantially different.  相似文献   

17.
Zuo L  Youtz DJ  Wold LE 《PloS one》2011,6(8):e23116
Diabetes mellitus and fine particulate matter from diesel exhaust (DEP) are both important contributors to the development of cardiovascular disease (CVD). Diabetes mellitus is a progressive disease with a high mortality rate in patients suffering from CVD, resulting in diabetic cardiomyopathy. Elevated DEP levels in the air are attributed to the development of various CVDs, presumably since fine DEP (<2.5 μm in diameter) can be inhaled and gain access to the circulatory system. However, mechanisms defining how DEP affects diabetic or control cardiomyocyte function remain poorly understood. The purpose of the present study was to evaluate cardiomyocyte function and reactive oxygen species (ROS) generation in isolated rat ventricular myocytes exposed overnight to fine DEP (0.1 μg/ml), and/or high glucose (HG, 25.5 mM). Our hypothesis was that DEP exposure exacerbates contractile dysfunction via ROS generation in cardiomyocytes exposed to HG. Ventricular myocytes were isolated from male adult Sprague-Dawley rats cultured overnight and sarcomeric contractile properties were evaluated, including: peak shortening normalized to baseline (PS), time-to-90% shortening (TPS(90)), time-to-90% relengthening (TR(90)) and maximal velocities of shortening/relengthening (±dL/dt), using an IonOptix field-stimulator system. ROS generation was determined using hydroethidine/ethidium confocal microscopy. We found that DEP exposure significantly increased TR(90), decreased PS and ±dL/dt, and enhanced intracellular ROS generation in myocytes exposed to HG. Further studies indicated that co-culture with antioxidants (0.25 mM Tiron and 0.5 mM N-Acetyl-L-cysteine) completely restored contractile function in DEP, HG and HG+DEP-treated myocytes. ROS generation was blocked in HG-treated cells with mitochondrial inhibition, while ROS generation was blocked in DEP-treated cells with NADPH oxidase inhibition. Our results suggest that DEP exacerbates myocardial dysfunction in isolated cardiomyocytes exposed to HG-containing media, which is potentially mediated by various ROS generation pathways.  相似文献   

18.
We have recently described patterns of adhesion of different types of leukocytes downstream of a backward facing step. Here the predicted fluid dynamics in channels incorporating backward facing steps are described, and related to the measured velocities of flowing cells, patterns of attachment and characteristics of rolling adhesion for neutrophils perfused over P-selectin. Deeper (upstream depth 300 microm, downstream depth 600 microm, maximum wall shear stress approximately 0.1 Pa) and shallower (upstream depth 260 microm, downstream depth 450 microm, maximum wall shear stress approximately 0.3 Pa) channels were compared. Computational fluid dynamics (CFD) predicted the presence of vortices downstream of the steps, distances to reattachment of flow, local wall shear stresses and components of velocity parallel and perpendicular to the wall. Measurements of velocities of perfused neutrophils agreed well with predictions, and suggested that adhesion to P-selectin should be possible in the regions of recirculating flow, but not downstream in re-established flow in the high shear channel. When channels were coated with a P-selectin-Fc chimaera, neutrophils were captured from flow and immobilised. Capture showed local maxima around the reattachment points, but was absent elsewhere in the high shear chamber. In the low shear chamber there was depression of adhesion just beyond the reattachment point because of expansion of flow and depletion of neutrophils near the wall. Inside the recirculation zones, adhesion decreased approaching the step because of an increasing, vertically upward velocity component. When channels were coated with P-selectin, neutrophils rolled in all regions, but lifted off the surface as they rolled backwards into low shear regions near the step. Rolling velocity in the recirculation zone was independent of shear stress, possibly because of the effects of vertical lift. We conclude that while local wall shear stress influences adhesive behavior, delivery of cells to the wall and their behavior after capture also depend on components of flow perpendicular to the wall.  相似文献   

19.
Superporous agarose beads contain both normal diffusion pores and special, very wide superpores through which part of the chromatographic flow is transported, a situation that may greatly improve the chromatographic performance. For the first time such pore flow was measured directly by following the movement of microparticles (dyed yeast cells) through superporous beads packed in a chromatographic bed. The passage of the microparticles through the superpores and through the interstitial pores was recorded by a microscope/video camera. The video recordings were subsequently used to determine flow paths as well as the convective fluid velocities in both the superpores and the interstitial pores. The superpore fluid velocity was found to be proportional to the ratio between the squares of the respective pore diameters, which is in agreement with the Kozeny-Carman equation. Values for two-dimensional and three-dimensional tortuosity of the flow paths were measured and calculated respectively.  相似文献   

20.
Propulsive forces generated by swimmers' hands and arms have, to date, been determined strictly through experimental testing. As an alternative to these complex and costly experiments, the present research has applied the numerical technique of computational fluid dynamics (CFD) to calculate the steady flow around a swimmer's hand and arm at various angles of attack. Force coefficients computed for the hand and arm compared well with steady-state coefficients determined experimentally. The simulations showed significant boundary layer separation from the arm and hand, suggesting that Bernoulli's equation should not be used to mathematically describe the lift generated by a swimmer. Additionally, "2D" lift was shown to be inaccurate for the arm at all angles of attack and for the hand near angles of attack of 90 degrees. Such simulations serve to validate the chosen CFD techniques, and are an important first step towards the use of CFD methods for determining swimming hydrodynamic forces in more complex unsteady flow conditions.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号