首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Orthodontic tooth movement occurs as a result of resorption and formation of the alveolar bone due to an applied load, but the stimulus responsible for triggering orthodontic tooth movement remains the subject of debate. It has been suggested that the periodontal ligament (PDL) plays a key role. However, the mechanical function of the PDL in orthodontic tooth movement is not well understood as most mechanical models of the PDL to date have ignored the fibrous structure of the PDL. In this study we use finite element (FE) analysis to investigate the strains in the alveolar bone due to occlusal and orthodontic loads when PDL is modelled as a fibrous structure as compared to modelling PDL as a layer of solid material. The results show that the tension-only nature of the fibres essentially suspends the tooth in the tooth socket and their inclusion in FE models makes a significant difference to both the magnitude and distribution of strains produced in the surrounding bone. The results indicate that the PDL fibres have a very important role in load transfer between the teeth and alveolar bone and should be considered in FE studies investigating the biomechanics of orthodontic tooth movement.  相似文献   

2.
The present study is part of a research project that includes different components for the simulation of orthodontic tooth movement and comparing experimental results. This concept includes the development of a bone remodelling algorithm, as well as experimental studies on tooth movement. After the acquisition and evaluation of specific experimental data of the patient's situation, the individual components have to be integrated to verify and forecast tooth movement. The aim is to design individual treatment devices as well as to shorten treatment while making it more effective. The geometry of the teeth and that of the surrounding alveolar bone both influence the orthodontic tooth movement. For this reason, an exact morphological tooth model for the valid simulation of the tooth movement is needed, and can be constructed from computed tomography data. Simulation of tooth movement can then be compared with "in vivo" measurements of the orthodontic tooth movement. In this study, a specially developed hybrid retraction spring is employed. This spring enables the application of a defined, almost constant force system. The "in vivo" determined tooth movement is simulated with the aid of special positioning and measuring devices. Meanwhile, the active force system can be determined by 6-component force/moment sensors. The experimentally measured force system, "in vivo" measurements of tooth movement and the CT model are now available for numerical simulation for the first time.  相似文献   

3.
The present study was designed to determine the underlying mechanism of low-intensity pulsed ultrasound (LIPUS) induced alveolar bone remodeling and the role of BMP-2 expression in a rat orthodontic tooth movement model. Orthodontic appliances were placed between the homonymy upper first molars and the upper central incisors in rats under general anesthesia, followed by daily 20-min LIPUS or sham LIPUS treatment beginning at day 0. Tooth movement distances and molecular changes were evaluated at each observation point. In vitro and in vivo studies were conducted to detect HGF (Hepatocyte growth factor)/Runx2/BMP-2 signaling pathways and receptor activator of NFκB ligand (RANKL) expression by quantitative real time PCR (qRT-PCR), Western blot and immunohistochemistry. At day 3, LIPUS had no effect on the rat orthodontic tooth movement distance and BMP-2-induced alveolar bone remodeling. However, beginning at day 5 and for the following time points, LIPUS significantly increased orthodontic tooth movement distance and BMP-2 signaling pathway and RANKL expression compared with the control group. The qRT-PCR and Western blot data in vitro and in vivo to study BMP-2 expression were consistent with the immunohistochemistry observations. The present study demonstrates that LIPUS promotes alveolar bone remodeling by stimulating the HGF/Runx2/BMP-2 signaling pathway and RANKL expression in a rat orthodontic tooth movement model, and LIPUS increased BMP-2 expression via Runx2 regulation.  相似文献   

4.
Orthodontic tooth movement (OTM) is an adaptive biomechanical response of dentoalveolar components to orthodontic forces, in which remodeling of the alveolar bone occurs in response to changes in the surrounding mechanical environment. In this study, we developed a framework for OTM simulation by combining an image-based voxel finite element method, with a surface-tracking level set method using three-dimensional computer models. For a case study to demonstrate its capability of expressing clinical tooth movement, we observed displacement and rotation of the tooth under three types of force conditions. The simulation results demonstrate that the proposed simulation method has the potential to predict clinical OTM.  相似文献   

5.
A knowledge of the mechanical processes triggered in the bone and periodontal ligament (PDL) by orthodontic forces applied to a tooth is of decisive importance for an understanding of the subsequent remodelling around the tooth. To investigate these mechanical relationships, three-dimensional finite element (FE) models of the first lower molar in the rat were established. On the basis of digitized serial histological sections, these FE models were generated semi-automatically. Using various simplified geometrical variations, an appropriate FE model for the analysis of the stress and strain distributions was established. The numerical analyses were carried out under a mesially directed force of 0.1 N. Stress distributions in the bone and PDL showed a similar pattern, while strains in the bone were lower than in the PDL by a factor of 10-5. The data confirm the assumption that strain patterns in the PDL may be the key stimulus of bone remodelling.  相似文献   

6.
Microcomputed tomography (microCT) analysis is a powerful tool for the evaluation of bone tissue because it provides access to the 3D microarchitecture of the bone. It is invaluable for regenerative medicine as it provides the researcher with the opportunity to explore the skeletal system both in vivo and ex vivo. The quantitative assessment of macrostructural characteristics and microstructural features may improve our ability to estimate the quality of newly formed bone. We have developed a unique procedure for analyzing data from microCT scans to evaluate bone structure and repair. This protocol describes the procedures for microCT analysis of three main types of mouse bone regeneration models (ectopic administration of bone-forming mesenchymal stem cells, and administration of cells after both long bone defects and cranial segmental bone defects) that can be easily adapted for a variety of other models. Precise protocols are crucial because the system is extremely user sensitive and results can be easily biased if standardized methods are not applied. The suggested protocol takes 1.5-3.5 h per sample, depending on bone tissue sample size, the type of equipment used, variables of the scanning protocol and the operator's experience.  相似文献   

7.
The orthodontic treatment is aimed to displace and/or rotate the teeth to obtain the functionally correct occlusion and the best aesthetics and consists in applying forces and/or couples to tooth crowns. The applied loads are generated by the elastic recovery of metallic wires linked to the tooth crowns by brackets. These loads generate a stress state into the periodontal ligament and hence, in the alveolar bone, causing the bone remodeling responsible for the tooth movement. The orthodontic appliance is usually designed on the basis of the clinical experience of the orthodontist. In this work, a quantitative approach for the prediction of the tooth movement is presented that has been developed as a first step to build up a computer tool to aid the orthodontist in designing the orthodontic appliance. The model calculates the tooth movement through time with respect to a fixed Cartesian frame located in the middle of the dental arch. The user interface panel has been designed to allow the orthodontist to manage the standard geometrical references and parameters usually adopted to design the treatment. Simulations of specific cases are reported for which the parameters of the model are selected in order to reproduce forecasts of tooth movement matching data published in experimental works.  相似文献   

8.

The orthodontic treatment is aimed to displace and/or rotate the teeth to obtain the functionally correct occlusion and the best aesthetics and consists in applying forces and/or couples to tooth crowns. The applied loads are generated by the elastic recovery of metallic wires linked to the tooth crowns by brackets. These loads generate a stress state into the periodontal ligament and hence, in the alveolar bone, causing the bone remodeling responsible for the tooth movement. The orthodontic appliance is usually designed on the basis of the clinical experience of the orthodontist. In this work, a quantitative approach for the prediction of the tooth movement is presented that has been developed as a first step to build up a computer tool to aid the orthodontist in designing the orthodontic appliance. The model calculates the tooth movement through time with respect to a fixed Cartesian frame located in the middle of the dental arch. The user interface panel has been designed to allow the orthodontist to manage the standard geometrical references and parameters usually adopted to design the treatment. Simulations of specific cases are reported for which the parameters of the model are selected in order to reproduce forecasts of tooth movement matching data published in experimental works.  相似文献   

9.
A simple overview of daily orthodontic practice involves use of brackets, wires and elastomeric modules. However, investigating the underlying effect of orthodontic forces shows various molecular and cellular changes. Also, orthodontics is in close relation with dentofacial orthopedics which involves bone regeneration. In this review current and future applications of stem cells(SCs) in orthodontics and dentofacial orthopedics have been discussed. For craniofacial anomalies, SCs have been applied to regenerate hard tissue(such as treatment of alveolar cleft) and soft tissue(such as treatment of hemifacial macrosomia). Several attempts have been done to reconstruct impaired temporomandibular joint. Also, SCs with or without bone scaffolds and growth factors have been used to regenerate bone following distraction osteogenesis of mandibular bone or maxillary expansion. Current evidence shows that SCs also have potential to be used to regenerate infrabony alveolar defects and move the teeth into regenerated areas. Future application of SCs in orthodontics could involve accelerating tooth movement, regenerating resorbed roots and expanding tooth movement limitations. However, evidence supporting these roles is weak and further studies are required to evaluate the possibility of these ideas.  相似文献   

10.
<正>畸牙移动是在机械力的作用下,通过对牙周膜产生牵张或压缩的力来引起牙周组织在生理限度内的组织改建,从而达到牙齿移动、矫治畸形的目的。由于没有明显的年龄限制,正畸矫治在全球范围已变得越来越普遍。因此,相关的研究也日益增多。牙齿移动的生物学基础是正畸力作用于牙周组织激活一系列信号转导通路,进而引起牙周膜的修复改建。为指导临床、加速正畸矫治疗程提供新的思路,本文综述了近年来有关正畸牙移动相关信号通路的研究进展。发现最新的研究集中在MAPK信号通路,Wnt/β-catenin信号通路,PI3K/AKt/m TOR信号通路,BMP-2信号通路,Caspase-3介导的凋亡通路较多。但是正畸牙移动引起的牙周组织改建是一个多种生物力学信号转导通路相互调节相互作用的过程,对于上述信号通路之间的相互关系还有待于我们更进一步的探索。  相似文献   

11.
Heterotopic ossification (HO) is the growth of extra-skeletal bone which occurs following trauma, burns, and in patients with genetic bone morphogenetic protein (BMP) receptor mutations. The clinical and laboratory evaluation of HO is dependent on radiographic imaging to identify and characterize these lesions. Here we show that despite its inadequacies, plain film radiography and single modality microCT continue to serve as a primary method of HO imaging in nearly 30% of published in vivo literature. Furthermore, we demonstrate that detailed microCT analysis is superior to plain film and single modality microCT radiography specifically in the evaluation of HO formed through three representative models due to its ability to 1) define structural relationships between growing extra-skeletal bone and normal, anatomic bone, 2) provide accurate quantification and growth rate based on volume of the space-occupying lesion, thereby facilitating assessments of therapeutic intervention, 3) identify HO at earlier times allowing for evaluation of early intervention, and 4) characterization of metrics of bone physiology including porosity, tissue mineral density, and cortical and trabecular volume. Examination of our trauma model using microCT demonstrated two separate areas of HO based on anatomic location and relationship with surrounding, normal bone structures. Additionally, microCT allows HO growth rate to be evaluated to characterize HO progression. Taken together, these data demonstrate the need for a paradigm shift in the evaluation of HO towards microCT as a standard tool for imaging.  相似文献   

12.
Micro-finite element (microFE) models based on high-resolution images have enabled the calculation of elastic properties of trabecular bone in vitro. Recently, techniques have been developed to image trabecular bone structure in vivo, albeit at a lesser resolution. The present work studies the usefulness of such in-vivo images for microFE analyses, by comparing their microFE results to those of models based on high-resolution micro-CT (microCT) images. Fifteen specimens obtained from human femoral heads were imaged first with a 3D-pQCT scanner at 165 microns resolution and a second time with a microCT scanner at 56 microns resolution. A third set of images with a resolution of 165 microns was created by downscaling the microCT measurements. The microFE models were created directly from these images. Orthotropic elastic properties and the average tissue von Mises stress of the specimens were calculated from six FE-analyses per specimen. The results of the 165 microns models were compared to those of the 56 microns model, which was taken as the reference model. The results calculated from the pQCT-based models, correlated excellent with those calculated from the reference model for both moduli (R2 > 0.95) and for the average tissue von Mises stress (R2 > 0.83). Results calculated from the downscaled micro-CT models correlated even better with those of the reference models (R2 > 0.99 for the moduli and R2 > 0.96 for the average von Mises stress). In the case of the 3D-pQCT based models, however, the slopes of the regression lines were less than one and had to be corrected. The prediction of the Poisson's ratios was less accurate (R2 > 0.45 and R2 > 0.67) for the models based on 3D-pQCT and downscaled microCT images respectively). The fact that the results from the downscaled and original microCT images were nearly identical indicates that the need for a correction in the case of the 3D-pQCT measurements was not due to the voxel size of the images but due to a higher noise level and a lower contrast in these images, in combination with the application of a filtering procedure at 165 micron images. In summary: the results of microFE models based on in-vivo images of the 3D-pQCT can closely resemble those obtained from microFE models based on higher resolution microCT system.  相似文献   

13.
Orthodontic treatments not only displace irregular teeth but also induce responses in surrounding bone tissues. Bone remodelling is regarded as the regulatory mechanism triggered by mechanical loading. This study was aimed at investigating the effect of orthodontic loading on both tooth movement and neighbouring bone density distribution. A set of computational algorithms incorporating both external and internal remodelling mechanisms was implemented into a patient-specific 3D finite element (FE) model to investigate and analyse orthodontic treatment under four typical modes of orthodontic loading. The consequence of orthodontic treatment was reproduced numerically by using this FE-based technique. The results indicated that the diverse modes of orthodontic loading would result in different magnitudes of tooth movement and particular morphology of bone density distribution. It is illuminated that the newly developed algorithms may replicate the clinical situation more closely compared with the previous proposed method.  相似文献   

14.
This study presents a biomechanical model of orthodontic tooth movement. Although such models have already been presented in the literature, most of them incorporate computationally expensive finite elements (FE) methods to determine the strain distribution in the periodontal ligament (PDL). In contrast, the biomechanical model presented in this work avoids the use of FE methods. The elastic deformation of the PDL is modelled using an analytical approach, which does not require setting up a 3D model of the tooth. The duration of the lag phase is estimated using the calculated hydrostatic stresses, and bone remodelling is predicted by modelling the alveolar bone as a viscous material. To evaluate the model, some typically used motion patterns were simulated and a sensitivity analysis was carried out on the parameters. Results show that despite some shortcomings, the model is able to describe commonly used motion patterns in orthodontic tooth movement, in both single- and multi-rooted teeth.  相似文献   

15.
The aim of the present study was to investigate experimentally the mechanical properties of tooth deflection under external loading. These properties have a significant impact on tooth movement during orthodontic treatment. The stresses and strains caused by tooth movement influence bone remodelling, which is the basis of orthodontic treatment. The movement of a tooth as a direct reaction to the forces acting on it is termed "initial" movement. It is nonlinear and has a clearly time-dependent component. While the initial tooth movement represents the totality of the reaction mechanisms of all the tissues of the tooth unit, it is determined primarily by the mechanical properties of the periodontal ligament (PDL). The PDL is the softest tissue of the tooth unit and is therefore subject to the largest deformations when forces act on the crown of the tooth. The objective of orthodontic treatment is to achieve as precise and rapid tooth movement as possible, without provoking such undesired effects as bone and root resorption. To enable the implementation of an optimal orthodontic force system that meets these requirements, a thorough knowledge of the biomechanics of tooth movement is a must.  相似文献   

16.
The periodontal ligament (PDL), a soft tissue connecting the tooth and the bone, is essential for tooth movement, bone remodeling and force dissipation. A collagenous network that connects the tooth root surface to the alveolar jaw bone is one of the major components of the PDL. The organization of the collagenous component and how it changes under load is still poorly understood. Here using a state-of-the-art custom-made loading apparatus and a humidified environment inside a microCT, we visualize the PDL collagenous network of a fresh rat molar in 3D at 1 μm voxel size without any fixation or contrasting agents. We demonstrate that the PDL collagen network is organized in sheets. The spaces between sheets vary thus creating dense and sparse networks. Upon vertical loading, the sheets in both networks are stretched into well aligned arrays. The sparse network is located mainly in areas which undergo compressive loading as the tooth moves towards the bone, whereas the dense network functions mostly in tension as the tooth moves further from the bone. This new visualization method can be used to study other non-mineralized or partially mineralized tissues, and in particular those that are subjected to mechanical loads. The method will also be valuable for characterizing diseased tissues, as well as better understanding the phenotypic expressions of genetic mutants.  相似文献   

17.
Abstract

Orthodontic tooth movement is mainly regulated by the biomechanical responses of loaded periodontal ligament (PDL). We investigated the effective intervals of orthodontic force in pure maxillary canine intrusion and extrusion referring to PDL hydrostatic stress and logarithmic strain. Finite element analysis (FEA) models, including a maxillary canine, PDL and alveolar bone, were constructed based on computed tomography (CT) images of a patient. The material properties of alveolar bone were non-uniformly defined using HU values of CT images; PDL was assumed to be a hyperelastic–viscoelastic material. The compressive stress and tensile stress ranging from 0.47 to 12.8?kPa and 18.8 to 51.2?kPa, respectively, were identified as effective for tooth movement; a strain 0.24% was identified as the lower limit of effective strain. The stress/strain distributions within PDL were acquired in canine intrusion and extrusion using FEA; root apex was the main force-bearing area in intrusion–extrusion movements and was more prone to resorption. Owing to the distinction of PDL biomechanical responses to compression and tension, the effective interval of orthodontic force was substantially lower in canine intrusion (80–90?g) than in canine extrusion (230–260?g). A larger magnitude of force remained applicable in canine extrusion. This study revised and complemented orthodontic biomechanical behaviours of tooth movement with intrusive–extrusive force and could further help optimize orthodontic treatment.  相似文献   

18.
Teeth sustain high loads over a lifetime and yet intact tooth failure is rare. The different structures of the tooth, jaw bone and the intervening soft periodontal ligament enable the tooth to endure repeated loading during mastication. Although mechanical and functional properties of the different components are thoroughly investigated, the manner in which the whole tooth functions under load is still enigmatic. A custom-made loading system inside a microCT scanner was used to directly visualize the root movements in relation to the jaw bone as the rat molar tooth was loaded. At low loads no contact was observed between the root surface and the bone, whereas at higher loads three specific contact areas between the root surface and the jaw bone were observed. These contact areas restrict tooth movement in the buccal-lingual direction, but enable the tooth to rock in a "seesaw" like manner in the distal-mesial direction. The contact areas appear to play a role in determining tooth motion and in turn define the manner in which the whole tooth moves when loaded. These observations are important for understanding basic structure-function relations of the tooth-PDL-bone system, and have direct implications for better understanding pathological and therapeutic processes in orthodontics, periodontics and jaw bone regeneration.  相似文献   

19.

New treatments for bone diseases require testing in animal models before clinical translation, and the mouse tibia is among the most common models. In vivo micro-Computed Tomography (microCT)-based micro-Finite Element (microFE) models can be used for predicting the bone strength non-invasively, after proper validation against experimental data. Different modelling techniques can be used to estimate the bone properties, and the accuracy associated with each is unclear. The aim of this study was to evaluate the ability of different microCT-based microFE models to predict the mechanical properties of the mouse tibia under compressive load. Twenty tibiae were microCT scanned at 10.4 µm voxel size and subsequently compressed at 0.03 mm/s until failure. Stiffness and failure load were measured from the load–displacement curves. Different microFE models were generated from each microCT image, with hexahedral or tetrahedral mesh, and homogeneous or heterogeneous material properties. Prediction accuracy was comparable among models. The best correlations between experimental and predicted mechanical properties, as well as lower errors, were obtained for hexahedral models with homogeneous material properties. Experimental stiffness and predicted stiffness were reasonably well correlated (R2 = 0.53–0.65, average error of 13–17%). A lower correlation was found for failure load (R2 = 0.21–0.48, average error of 9–15%). Experimental and predicted mechanical properties normalized by the total bone mass were strongly correlated (R2 = 0.75–0.80 for stiffness, R2 = 0.55–0.81 for failure load). In conclusion, hexahedral models with homogeneous material properties based on in vivo microCT images were shown to best predict the mechanical properties of the mouse tibia.

  相似文献   

20.
Orthodontic treatment induces various biological responses, including tooth movement and remodeling of alveolar bone. Although some studies have investigated the contribution of orthodontic procedures to changes in saliva conditions, little is known about the effects of different treatment durations on the saliva proteome. To identify the discriminating protein profiles in unstimulated whole saliva of orthodontic patients with different treatment durations, we used matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) combined with magnetic bead, and peptide mass fingerprints were created by scanning MS signals. Saliva samples from 40 patients (10 in each of four groups: the group without an appliance and groups under treatment for 2, 7, and 12 months) were analyzed. The results showed eight mass peaks with significant differences. Furthermore, mass peak intensities at proteins 1817.7, 2010.7, 2744 and 2710.2 Da represented a steady time-dependent increasing trend, whereas protein 4134 Da exhibited a decreasing tendency. Differential expression of the peptidome profile also occurred in the multiple comparisons, and we established a fitting model. Thus, the potential discriminating biomarkers investigated in this study reflected the complicated changes in periodontal tissues during orthodontic treatment and indicated dynamic interactions between orthodontic treatment and the saliva proteome. The results provide novel insights into alterations in salivary proteins due to different orthodontic treatment durations and may lead to the development of a therapeutic monitoring strategy for orthodontics.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号