首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 625 毫秒
1.
Abstract

Spectral element computational simulations of the conservation of mass, momentum and species equations are performed to investigate the flow and oxygen transfer characteristics of an Intravenous Membrane Oxygenator (IMO). The simulations consider a three-dimensional IMO computational model consisting of equally-spaced fibers, an elastic balloon with non-permeable walls positioned longitudinally within the vena cava, and a Newtonian and time-dependent incompressible flow. Flow characteristics and oxygen transfer parameters are determined for operating conditions of a stationary and a pulsating balloon. For the stationary balloon configuration the flow is two-dimensional, parallel, laminar and without secondary flows for the Reynolds number range of 5.7-455.2. Evaluations of the oxygen transfer characteristics for the stationary balloon indicate that the main transport mechanisms are diffusion and convection in the crosswise and streamwise directions, respectively. Additionally, evaluations of oxygen transfer rates and Sherwood numbers in this Reynolds number range indicate that the oxygen transfer rate reaches an asymptotic limit at relatively moderate Reynolds numbers. For the pulsating balloon, flow characteristic results demonstrate the existence of a strong secondary flow around the fiber, and between the balloon and the fiber. This secondary flow induces oscillatory crosswise and streamwise velocities and a seemingly random spanwise flow which enhances the flow mixing as well as the transport of oxygen from the fiber surface to the bulk flow.  相似文献   

2.
Computational investigations of flow mixing and oxygen transfer characteristics in an intravenous membrane oxygenator (IMO) are performed by direct numerical simulations of the conservation of mass, momentum, and species equations. Three-dimensional computational models are developed to investigate flow-mixing and oxygen-transfer characteristics for stationary and pulsating balloons, using the spectral element method. For a stationary balloon, the effect of the fiber placement within the fiber bundle and the number of fiber rings is investigated. In a pulsating balloon, the flow mixing characteristics are determined and the oxygen transfer rate is evaluated. For a stationary balloon, numerical simulations show two well-defined flow patterns that depend on the region of the IMO device. Successive increases of the Reynolds number raise the longitudinal velocity without creating secondary flow. This characteristic is not affected by staggered or non-staggered fiber placement within the fiber bundle. For a pulsating balloon, the flow mixing is enhanced by generating a three-dimensional time-dependent flow characterized by oscillatory radial, pulsatile longitudinal, and both oscillatory and random tangential velocities. This three-dimensional flow increases the flow mixing due to an active time-dependent secondary flow, particularly around the fibers. Analytical models show the fiber bundle placement effect on the pressure gradient and flow pattern. The oxygen transport from the fiber surface to the mean flow is due to a dominant radial diffusion mechanism, for the stationary balloon. The oxygen transfer rate reaches an asymptotic behavior at relatively low Reynolds numbers. For a pulsating balloon, the time-dependent oxygen-concentration field resembles the oscillatory and wavy nature of the time-dependent flow. Sherwood number evaluations demonstrate that balloon pulsations enhance the oxygen transfer rate, even for smaller flow rates.  相似文献   

3.
A computational methodology for accurately predicting flow and oxygen-transport characteristics and performance of an intravenous membrane oxygenator (IMO) device is developed, tested, and validated. This methodology uses extensive numerical simulations of three-dimensional computational models to determine flow-mixing characteristics and oxygen-transfer performance, and analytical models to indirectly validate numerical predictions with experimental data, using both blood and water as working fluids. Direct numerical simulations for IMO stationary and pulsating balloons predict flow field and oxygen transport performance in response to changes in the device length, number of and balloon pulsation frequency. Multifiber models are used to investigate interfiber interference and length effects for a stationary balloon whereas a single fiber model is used to analyze the effect of balloon pulsations on velocity and oxygen concentration fields and to evaluate oxygen transfer rates. An analytical lumped model is developed and validated by comparing its numerical predictions with experimental data. Numerical results demonstrate that oxygen transfer rates for a stationary balloon regime decrease with increasing number of fibers, independent of the fluid type. The oxygen transfer rate ratio obtained with blood and water is approximately two. Balloon pulsations show an effective and enhanced flow mixing, with time-dependent recirculating flows around the fibers regions which induce higher oxygen transfer rates. The mass transfer rates increase approximately 100% and 80%, with water and blood, respectively, compared with stationary balloon operation. Calculations with combinations of frequency, number of fibers, fiber length and diameter, and inlet volumetric flow rates, agree well with the reported experimental results, and provide a solid comparative base for analysis, predictions, and comparisons with numerical and experimental data.  相似文献   

4.
Endothelial cells, covering the inner surface of vessels and the heart, are permanently exposed to fluid flow, which affects the endothelial structure and the function. The response of endothelial cells to fluid shear stress is frequently investigated in cone-plate systems. For this type of device, we performed an analytical and numerical analysis of the steady, laminar, three-dimensional flow of a Newtonian fluid at low Reynolds numbers. Unsteady oscillating and pulsating flow was studied numerically by taking the geometry of a corresponding experimental setup into account. Our investigation provides detailed information with regard to shear-stress distribution at the plate as well as secondary flow. We show that: (i) there is a region on the plate where shear stress is almost constant and an analytical approach can be applied with high accuracy; (ii) detailed information about the flow in a real cone-plate device can only be obtained by numerical simulations; (iii) the pulsating flow is quasi-stationary; and (iv) there is a time lag on the order of 10(-3) s between cone rotation and shear stress generated on the plate.  相似文献   

5.
The pulsatile flow and gas transport of a Newtonian passive fluid across an array of cylindrical microfibers are numerically investigated. It is related to an implantable, artificial lung where the blood flow is driven by the right heart. The fibers are modeled as either squared or staggered arrays. The pulsatile flow inputs considered in this study are a steady flow with a sinusoidal perturbation and a cardiac flow. The aims of this study are twofold: identifying favorable array geometry/spacing and system conditions that enhance gas transport; and providing pressure drop data that indicate the degree of flow resistance or the demand on the right heart in driving the flow through the fiber bundle. The results show that pulsatile flow improves the gas transfer to the fluid compared to steady flow. The degree of enhancement is found to be significant when the oscillation frequency is large, when the void fraction of the fiber bundle is decreased, and when the Reynolds number is increased; the use of a cardiac flow input can also improve gas transfer. In terms of array geometry, the staggered array gives both a better gas transfer per fiber (for relatively large void fraction) and a smaller pressure drop (for all cases). For most cases shown, an increase in gas transfer is accompanied by a higher pressure drop required to power the flow through the device.  相似文献   

6.
The flow of cerebrospinal fluid (CSF) in a patient-specific model of the subarachnoid space in a Chiari I patient was investigated using numerical simulations. The pulsating CSF flow was modeled using a time-varying velocity pulse based on peak velocity measurements (diastole and systole) derived from a selection of patients with Chiari I malformation. The present study introduces the general definition of the Reynolds number to provide a measure of CSF flow instability to give an estimate of the possibility of turbulence occurring in CSF flow. This was motivated by the fact that the combination of pulsating flow and the geometric complexity of the spinal canal may result in local Reynolds numbers that are significantly higher than the commonly used global measure such that flow instabilities may develop into turbulent flow in these regions. The local Reynolds number was used in combination with derived statistics to characterize the flow. The results revealed the existence of both local unstable regions and local regions with velocity fluctuations similar in magnitude to what is observed in fully turbulent flows. The results also indicated that the fluctuations were not self-sustained turbulence, but rather flow instabilities that may develop into turbulence. The case considered was therefore believed to represent a CSF flow close to transition.  相似文献   

7.
In order to understand mechanisms of gas and aerosol transport in the human respiratory system airflow in the upper airways of a pediatric subject (male aged 5) was calculated using Computational Fluid Dynamic techniques. An in vitro reconstruction of the subject's anatomy was produced from MRI images. Flow fields were solved for steady inhalation at 6.4 and 8 LPM. For validation of the numerical solution, airflow in an adult cadaver based trachea was solved using identical numerical methods. Comparisons were made between experimental results and computational data of the adult model to determine solution validity. It was found that numerical simulations can provide an accurate representation of axial velocities and turbulence intensity. Data on flow resistance, axial velocities, secondary velocity vectors, and turbulent kinetic energy are presented for the pediatric case. Turbulent kinetic energy and axial velocities were heavily dependant on flow rate, whereas turbulence intensity varied less over the flow rates studied. The laryngeal jet from an adult model was compared to the laryngeal jet in the pediatric model based on Tracheal Reynolds number. The pediatric case indicated that children show axial velocities in the laryngeal jet comparable to adults, who have much higher tracheal Reynolds numbers than children due to larger characteristic dimensions. The intensity of turbulence follows a similar trend, with higher turbulent kinetic energy levels in the pediatric model than would be expected from measurements in adults at similar tracheal Reynolds numbers. There was reasonable agreement between the location of flow structures between adults and children, suggesting that an unknown length scale correlation factor could exist that would produce acceptable predictions of pediatric velocimetry based off of adult data sets. A combined scale for turbulent intensity as well may not exist due to the complex nature of turbulence production and dissipation.  相似文献   

8.
The effect of blood velocity pulsations on bioheat transfer is studied. A simple model of a straight rigid blood vessel with unsteady periodic flow is considered. A numerical solution that considers the fully coupled Navier-Stokes and energy equations is used for the simulations. The influence of the pulsation rate on the temperature distribution and energy transport is studied for four typical vessel sizes: aorta, large arteries, terminal arterial branches, and arterioles. The results show that: the pulsating axial velocity produces a pulsating temperature distribution; reversal of flow occurs in the aorta and in large vessels, which produces significant time variation in the temperature profile. Change of the pulsation rate yields a change of the energy transport between the vessel wall and fluid for the large vessels. For the thermally important terminal arteries (0.04-1 mm), velocity pulsations have a small influence on temperature distribution and on the energy transport out of the vessels (8 percent for the Womersley number corresponding to a normal heart rate). Given that there is a small difference between the time-averaged unsteady heat flux due to a pulsating blood velocity and an assumed nonpulsating blood velocity, it is reasonable to assume a nonpulsating blood velocity for the purposes of estimating bioheat transfer.  相似文献   

9.
We perform numerical simulations of the swimming of a three-linkage articulated system in a moderately viscous regime. The computational methodology focuses on the creation, diffusion and transport of vorticity from the surface of the bodies into the fluid. The simulations are dynamically coupled, in that the motion of the three-linkage swimmer is computed simultaneously with the dynamics of the fluid. The novel coupling scheme presented in this work is the first to exploit the relationship between vorticity creation and body dynamics. The locomotion of the system, when subject to undulatory inputs of the hinges, is computed at Reynolds numbers of 200 and 1000. It is found that the forward swimming speed increases with the Reynolds number, and that in both cases the swimming is slower than in an inviscid medium. The vortex shedding is examined, and found to exhibit behavior consistent with experimental flow visualizations of fish.  相似文献   

10.
The influence of time-dependent flows on oxygen transport from hollow fibers was computationally and experimentally investigated. The fluid average pressure drop, a measure of resistance, and the work required by the heart to drive fluid past the hollow fibers were also computationally explored. This study has particular relevance to the development of an artificial lung, which is perfused by blood leaving the right ventricle and in some cases passing through a compliance chamber before entering the device. Computational studies modeled the fiber bundle using cylindrical fiber arrays arranged in in-line and staggered rectangular configurations. The flow leaving the compliance chamber was modeled as dampened pulsatile and consisted of a sinusoidal perturbation superimposed on a steady flow. The right ventricular flow was modeled to depict the period of rapid flow acceleration and then deceleration during systole followed by zero flow during diastole. Experimental studies examined oxygen transfer across a fiber bundle with either steady, dampened pulsatile, or right ventricular flow. It was observed that the dampened pulsatile flow yielded similar oxygen transport efficiency to the steady flow, while the right ventricular flow resulted in smaller oxygen transport efficiency, with the decrease increasing with Re. Both computations and experiments yielded qualitatively similar results. In the computational modeling, the average pressure drop was similar for steady and dampened pulsatile flows and larger for right ventricular flow while the pump work required of the heart was greatest for right ventricular flow followed by dampened pulsatile flow and then steady flow. In conclusion, dampening the artificial lung inlet flow would be expected to maximize oxygen transport, minimize work, and thus improve performance.  相似文献   

11.
Axial gas transport due to the interaction between radial mixing and radially nonuniform axial velocities is responsible for gas transport in thick airways during High-frequency oscillatory ventilation (HFO). Because the airways can be characterized by a bifurcating tube network, the secondary flow in the curved portion of a bifurcating tube contributes to cross-stream mixing. In this study the oscillatory flow and concentration fields through a single symmetrical airway bifurcating tube model were numerically analyzed by solving three-dimensional Navier-Stokes and mass concentration equations with the SIMPLER algorithm. The simulation conditions were for a Womersley number, alpha = 9.1 and Reynolds numbers in the parent tube between 200 and 1000, corresponding to Dn2/alpha 4 in the curved portion between 2 and 80, where Dn is Dean number. For comparison with the results from the bifurcating tube, we calculated the velocity and concentration fields for fully developed oscillatory flow through a curved tube with a curvature rate of 1/10, which is identical to the curved portion of the bifurcating tube. For Dn2/alpha 4 < or = 10 in the curved portion of the bifurcating tube, the flow divider and area changes dominate the axial gas transport, because the effective diffusivity is greater than in either a straight or curved tube, in spite of low secondary velocities. However, for Dn2/alpha 4 > or = 20, the gas transport characteristics in a bifurcation are similar to a curved tube because of the significant effect of secondary flow.  相似文献   

12.
Relatively inefficient heat/mass transfer is characteristic of tubular devices if the Reynolds number is low. One method of improving the heat/mass transfer efficiency of such devices is by inducing transverse laminar secondary circulations that are superimposed on the primary flow field; the resulting transverse velocity components lead to fluid mixing and hence augmented mass transfer in the tube lumen. The present work is a theoretical and experimental investigation of the enhanced transport in rotating, nonaligned, straight tubes, a method of transport enhancement that utilizes Coriolis acceleration to create transverse fluid mixing. This technique couples the transport advantages of coiled tubes with the design advantages of straight tubes. The overall mass balance equation is numerically solved for transfer into fluids flowing steadily through rotating nonaligned straight tubes. This solution, for small Coriolis disturbances, incorporates a third order perturbation solution for the primary and secondary flow fields. For sufficiently small Coriolis disturbances the bulk concentration increase is found to be uniquely determined by the value of a single similarity parameter. As the Coriolis disturbance is increased, however, two additional parameters are required to accurately characterize the mass transfer. In general, increasing the Coriolis accelerations results in an increase in mass transfer. There are solution regimens, however, in which increasing this acceleration can lead to a decrease in mass transfer efficiency. This interesting phenomena, which has important design implications, appears to result from velocity-weighting effects on the exiting sample. Experiments, involving the measurement of oxygen transferred into water and blood, produced data that agree with the theoretical predictions.  相似文献   

13.
The mass transfer behavior in the recirculation region downstream of an axisymmetric sudden expansion was examined. The Reynolds number, 500, and Schmidt number, 3200, were selected to model the mass transfer of molecules, such as ADP, in the arterial system. In a first step the transient mass transport applying zero diffusive flux at the wall was analyzed using experiments and two computational codes. The two codes were FLUENT, a commercially available finite volume method, and FTSP, a finite element code developed at Graz University of Technology. The comparison of the transient wall concentration values determined by the three methods was excellent and provides a measure of confidence for computational mass transfer calculations in convection dominated, separated flows. In a second step the effect of the flow separation on the stationary mass transport applying a permeability boundary condition at the water-permeable wall was analyzed using the finite element code FTSP. The results show an increase of luminal ADP surface concentration in the upstream and in the downstream tube of the sudden expansion geometry in the range of six and twelve percent of the bulk flow concentration. The effect of flow separation in the downstream tube on the wall concentration is a decrease of about ten percent of the difference between wall concentration and bulk concentration occurring at nearly fully developed flow at the downstream region at a distance of 66 downstream tube diameters from the expansion. The decrease of ADP flux into the wall is in the range of three percent of the flux at the downstream region.  相似文献   

14.
The combined influence of an asymmetric shape and surface irregularities has been explored in a computational study of flow through arterial stenoses with 48% areal occlusion. Contrary to the conclusion of an earlier investigation, namely that the resistance to laminar flow through a stenosed artery is being reduced in the presence of surface irregularities, the present predictions demonstrate that the flow resistance is practically unaffected by surface irregularities at low Reynolds numbers, whereas an excess pressure drop up to 10% above that for a smooth stenosis is observed for higher Reynolds numbers. For a given areal occlusion, the flow resistance is reduced with increasing degree of stenosis asymmetry and this effect may more than outweigh the influence of surface irregularities. This effect is moreover prevailing throughout the entire range of Reynolds numbers considered.  相似文献   

15.
The distributions of mass transfer rate and wall shear stress in sinusoidal laminar pulsating flow through a two-dimensional asymmetric stenosed channel have been studied experimentally and numerically. The distributions are measured by the electrochemical method. The measurement is conducted at a Reynolds number of about 150, a Schmidt number of about 1000, a nondimensional pulsating frequency of 3.40, and a nondimensional flow amplitude of 0.3. It is suggested that the deterioration of an arterial wall distal to stenosis may be greatly enhanced by fluid dynamic effects.  相似文献   

16.
We have developed a bioreactor vessel design which has the advantages of simplicity and ease of assembly and disassembly, and with the appropriately determined flow rate, even allows for a scaffold to be suspended freely regardless of its weight. This article reports our experimental and numerical investigations to evaluate the performance of a newly developed non-perfusion conical bioreactor by visualizing the flow through scaffolds with 45 degrees and 90 degrees fiber lay down patterns. The experiments were conducted at the Reynolds numbers (Re) 121, 170, and 218 based on the local velocity and width of scaffolds. The flow fields were captured using short-time exposures of 60 microm particles suspended in the bioreactor and illuminated using a thin laser sheet. The effects of scaffold fiber lay down pattern and Reynolds number were obtained and correspondingly compared to results obtained from a computational fluid dynamics (CFD) software package. The objectives of this article are twofold: to investigate the hypothesis that there may be an insufficient exchange of medium within the interior of the scaffold when using our non-perfusion bioreactor, and second, to compare the flows within and around scaffolds of 45 degrees and 90 degrees fiber lay down patterns. Scaffold porosity was also found to influence flow patterns. It was therefore shown that fluidic transport could be achieved within scaffolds with our bioreactor design, being a non-perfusion vessel. Fluid velocities were generally same of the same or one order lower in magnitude as compared to the inlet flow velocity. Additionally, the 90 degrees fiber lay down pattern scaffold was found to allow for slightly higher fluid velocities within, as compared to the 45 degrees fiber lay down pattern scaffold. This was due to the architecture and pore arrangement of the 90 degrees fiber lay down pattern scaffold, which allows for fluid to flow directly through (channel-like flow).  相似文献   

17.
A pulsating flow of medium was used to alleviate diffusion and transport limitations in a hollow fiber bioreactor containing a human hepatoblastoma cell line. The strategy is easy to implement but effective. The pulsating flow is introduced by a solenoid pinch valve at the outlet of the bioreactor and regulated by a timing circuit. In a permeability test, the system with pulsating flow had much less membrane fouling as compared to the control, a conventional hollow fiber unit. In hepatocyte culture test runs, the pulsating-flow bioreactor demonstrated the ability to maintain a higher cell viability. Histological sections indicated significantly smaller necrotic regions in the pulsating-flow bioreactor as compared to the conventional unit.  相似文献   

18.
Flow visualization and wall pressure measurements were made in a smooth reverse curvature model that conformed to the gentle "s" shape of a left femoral artery angiogram of a patient in a clinical trial. Observed lesion localization at the inner (lesser) curvatures appeared to be associated with secondary flows in the wall vicinity directed toward the inner curvatures that tended to reverse direction in the flow entering the reverse curvature region. Moderate flow resistance increases of about 20 percent above the Poiseuille flow relation were found at the higher physiological Reynolds numbers Re above about 600-700 and thus Dean numbers for steady flow. For pulsatile flow simulation, flow resistances did not increase up to the largest Re of 470 tested. Apparently, the large variations in velocity during the cardiac cycle disrupted the stronger secondary flow patterns observed at the higher Reynolds numbers for steady flow.  相似文献   

19.
A previously introduced degenerate diffusion-reaction model of biofilm growth and disinfection is extended to account for convective transport of oxygen and disinfectants in an aqueous environment. To achieve this in a computationally efficient manner we employ a thin-film approximation to the (Navier)-Stokes equations that can be solved analytically. In numerical experiments, we investigate how the convective transport of nutrients and disinfectants due to bulk flow hydrodynamics affects the balance between growth and disinfection processes. It is found that the development of biofilms can be significantly affected by the flow field even at extremely low Reynolds numbers. While it is natural to expect that increased bulk flow velocities imply increased mass transfer of both, nutrients and disinfectants, and hence an acceleration of both, growth and decay of biomass, it is found, furthermore, that in many instances the actual flow conditions, determine the success or failure of disinfection, i.e. persistence or extinction of a biofilm community.  相似文献   

20.
The deposition of ultrafine aerosols in the respiratory tract presents a significant health risk due to the increased cellular-level response that these particles may invoke. However, the effects of geometric simplifications on local and regional nanoparticle depositions remain unknown for the oral airway and throughout the respiratory tract. The objective of this study is to assess the effects of geometric simplifications on diffusional transport and deposition characteristics of inhaled ultrafine aerosols in models of the extrathoracic oral airway. A realistic model of the oral airway with the nasopharynx (NP) included has been constructed based on computed tomography scans of a healthy adult in conjunction with measurements reported in the literature. Three other geometries with descending degrees of physical realism were then constructed with successive geometric simplifications of the realistic model. A validated low Reynolds number k-omega turbulence model was employed to simulate laminar, transitional, and fully turbulent flow regimes for the transport of 1-200 nm particles. Results of this study indicate that the geometric simplifications considered did not significantly affect the total deposition efficiency or maximum local deposition enhancement of nanoparticles. However, particle transport dynamics and the underlying flow characteristics such as separation, turbulence intensity, and secondary motions did show an observable sensitivity to the geometric complexity. The orientation of the upper trachea was shown to be a major factor determining local deposition downstream of the glottis and should be retained in future models of the respiratory tract. In contrast, retaining the NP produced negligible variations in airway dynamics and could be excluded for predominantly oral breathing conditions. Results of this study corroborate the use of existing diffusion correlations based on a circular oral airway model. In comparison to previous studies, an improved correlation for the deposition of nanoparticles was developed based on a wider range of particle sizes and flow rates, which captures the dependence of the Sherwood number on both Reynolds and Schmidt numbers.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号