首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The deterioration of cancellous bone structure due to aging and disease is characterized by a conversion from plate elements to rod elements. Consequently the terms “rod-like” and “plate-like” are frequently used for a subjective classification of cancellous bone. In this work a new morphometric parameter called Structure Model Index (SMI) is introduced, which makes it possible to quantify the characteristic form of a three-dimensionally described structure in terms of the amount of plates and rod composing the structure. The SMI is calculated by means of three-dimensional image analysis based on a differential analysis of the triangulated bone surface. For an ideal plate and rod structure the SMI value is 0 and 3, respectively, independent of the physical dimensions. For a structure with both plates and rods of equal thickness the value lies between 0 and 3, depending on the volume ratio of rods and plates. The SMI parameter is evaluated by examining bone biopsies from different skeletal sites. The bone samples were measured three-dimensionally with a micro-CT system. Samples with the same volume density but varying trabecular architecture can uniquely be characterized with the SMI. Furthermore the SMI values were found to correspond well with the perceived structure type.  相似文献   

2.
The three-dimensional architecture of trabecular bone has structural trends related to physical function as described by Wolff's law. Mathematical modelling provides a means of analysing these structures through the use of simplified representations. A single measure of mineralized bone volume per unit volume of structure (Vv) and the surface area of mineralized bone per unit volume of structure (Sv) does not identify a particular architecture in any detail; the way in which Sv changes in relation to Vv does provide this information as the structure remodels. A series of structures using the elements of plates and rods were created. The rates of change of Sv with respect to Vv for trabecular structures give insight into differences in such models. Structures in the femoral head and iliac crest were analysed by power curve regression. In the principal compressive region, just above the medial cortex, advanced osteoarthritis was associated with a preferential loss of rods from the normal trabecular structure, resulting in a more plate-like architecture. The iliac crest remodelling that takes place in the osteoporotic appears to be the result of a generalised bone loss with some of the thinner elements of the structure being removed completely, resulting in an increase in unit cell dimension. The consequence of changing unit cell size has a major impact on surface availability for osteoblastic and osteoclastic activity. The simple plate model as a basis for the stereological analysis of trabecular structures is therefore limited because of the mixed plate and rod nature of trabecular architecture.  相似文献   

3.
Trabecular plates play an important role in determining elastic moduli of trabecular bone. However, the relative contribution of trabecular plates and rods to strength behavior is still not clear. In this study, individual trabeculae segmentation (ITS) and nonlinear finite element (FE) analyses were used to evaluate the roles of trabecular types and orientations in the failure initiation and progression in human vertebral trabecular bone. Fifteen human vertebral trabecular bone samples were imaged using micro computed tomography (μCT), and segmented using ITS into individual plates and rods by orientation (longitudinal, oblique, and transverse). Nonlinear FE analysis was conducted to perform a compression simulation for each sample up to 1% apparent strain. The apparent and relative trabecular number and tissue fraction of failed trabecular plates and rods were recorded during loading and data were stratified by trabecular orientation. More trabecular rods (both in number and tissue fraction) failed at the initiation of compression (0.1–0.2% apparent strain) while more plates failed around the apparent yield point (>0.7% apparent strain). A significant correlation between plate bone volume fraction (pBV/TV) and apparent yield strength was found (r2=0.85). From 0.3% to 1% apparent strain, significantly more longitudinal trabecular plate and transverse rod failed than other types of trabeculae. While failure initiates at rods and rods fail disproportionally to their number, plates contribute significantly to the apparent yield strength because of their larger number and tissue volume. The relative failed number and tissue fraction at apparent yield point indicate homogeneous local failure in plates and rods of different orientations.  相似文献   

4.
H Wang  B Ji  XS Liu  XE Guo  Y Huang  KC Hwang 《Journal of biomechanics》2012,45(14):2417-2425
Bone remodeling is a complex dynamic process, which modulates both bone mass and bone microstructure. In addition to bone mass, bone microstructure is an important contributor to bone quality in osteoporosis and fragility fractures. However, the quantitative knowledge of evolution of three-dimensional (3D) trabecular microstructure in adaptation to the external forces is currently limited. In this study, a new 3D simulation method of remodeling of human trabecular bone was developed to quantitatively study the dynamic evolution of bone mass and trabecular microstructure in response to different external loading conditions. The morphological features of trabecular plate and rod, such as thickness and number density in different orientations were monitored during the remodeling process using a novel imaging analysis technique, namely Individual Trabecula Segmentation (ITS). We showed that the volume fraction and microstructures of trabecular bone including, trabecular type and orientation, were determined by the applied mechanical load. Particularly, the morphological parameters of trabecular plates were more sensitive to the applied load, indicating that they played the major role in the mechanical properties of the trabecular bone. Reducing the applied load caused severe microstructural deteriorations of trabecular bone, such as trabecular plate perforation, rod breakage, and a conversion from plates to rods.  相似文献   

5.
A sensitivity analysis of the volumetric spatial decomposition algorithm   总被引:1,自引:0,他引:1  
Recently, we proposed a new computational approach for the volumetric spatial decomposition of a three-dimensional bone structure into its basic rod and plate elements. This method was based on an image skeletonization approach, where two model parameters were used to identify an ideal skeleton. The goal of this study was to estimate the sensitivity of local morphometric indices to these two model parameters. Our results showed that the rod derived indices behaved more smoothly than plate derived indices, which suggests that rod derived indices are more trustworthy. The results also demonstrated that it was reasonable to reduce the model to only one parameter by setting the noise parameter n to twice the value of the slenderness parameter s. In conclusion, we found that local morphometric indices are reliable measures showing large differences between samples and thus may shed new light on structural differences of trabecular bone in a local fashion by adequately choosing one single optimization parameter.  相似文献   

6.
Individual trabecula segmentation (ITS) technique can decompose the trabecular bone network into individual trabecular plates and rods and is capable of quantifying the plate/rod-related microstructural characteristics of trabecular bone. This novel technique has been shown to be able to provide in-depth insights into micromechanics and failure mechanisms of human trabecular bone, as well as to distinguish the fracture status independent of area bone mineral density in clinical applications. However, the plate/rod microstructural parameters from ITS have never been correlated to experimentally determined mechanical properties of human trabecular bone. In this study, on-axis cylindrical trabecular bone samples from human proximal tibia (n=22), vertebral body (n=10), and proximal femur (n=21) were harvested, prepared, scanned using micro computed-tomography (µCT), analyzed with ITS and mechanically tested. Regression analyses showed that the plate bone volume fraction (pBV/TV) and axial bone volume fraction (aBV/TV) calculated by ITS analysis correlated the best with elastic modulus (R2=0.96–0.97) and yield strength (R2=0.95–0.96). Trabecular plate-related microstructural parameters correlated highly with elastic modulus and yield strength, while most rod-related parameters were found inversely and only moderately correlated with the mechanical properties. In addition, ITS analysis also identified that trabecular bone at human femoral neck had the highest trabecular plate-related parameters while the other sites were similar with each other in terms of plate–rod microstructure.  相似文献   

7.
Models of regular cellular-solids representing femoral head 'medial group' bone were used to (1) compare thickness data for plate-like and beam-like structures at realistic surface areas and densities; (2) test the validity of a standard formula for trabecular thickness (Tb.Th); and (3) study how systematic changes in cancellous bone thicknesses, spacing, and face-connectivity affect relative density and surface area. Models of different face-connectivities, produced by plate removal from the unit cell, were fitted to bone density and surface area data. The medial group bone was anisotropic: the supero-inferior (SI) direction was the principal direction for bone plate alignment and the plane normal to this had the largest number of bone/void intersections per unit line length (P(I)). A comparison of boundary perimeter per unit area data, in planes normal to SI, with surface area data placed the medial group bone between prismatic structures in which walls are parallel to one principal direction and isotropic structures. Selective removal of plates from a closed-cell model produced a similar result. For the same relative density and surface-area, plate-like models had significantly thinner cross-sections than beam-like models. The formula for Tb.Th produced overestimates of model plate thickness by up to 20% at realistic femoral cancellous densities. Trends in data on surface area to volume ratio and density observed on sampled medial group bone could be simulated by plate thickness changes on models of intermediate face-connectivity (approximately 1.5) or by plate removal from models with relatively thick and short (low aspect-ratio) plates. The latter mechanism is unrealistic for it resulted in beam-like structures at low 'medial group' densities, an architecture unlike the predominantly plate-like bone in the sample.  相似文献   

8.
The mechanical behaviour of cancellous bone   总被引:23,自引:0,他引:23  
Cancellous bone has a cellular structure: it is made up of a connected network of rods and plates. Because of this, its mechanical behaviour is similar to that of other cellular materials such as polymeric foams. A recent study on the mechanisms of deformation in such materials has led to an understanding of how their mechanical properties depend on their relative density, cell wall properties and cell geometry. In this paper, the results of this previous study are applied to cancellous bone in an attempt to further understand its mechanical behaviour. The results of the analysis agree reasonably well with experimental data available in the literature.  相似文献   

9.
145 women showing clinical and radiological signs of involutional osteoporosis of the spine were biopsed at the ilium for histomorphometric analysis of bone mass including trabecular bone volume and parameters reflecting the spatial distribution of bony elements (mean trabecular plate thickness, density and separation). Results were compared with an age-matched population of 22 healthy females. Postmenopausal osteoporotics (i.e. younger than 75 years) were characterized by a significant reduction in trabecular bone volume, plate density and thickness, while senile osteoporotics (i.e. older than 75 years) did not exhibit any difference with controls. 51% of the osteoporotic patients had a trabecular bone volume higher than the spontaneous vertebral crush threshold defined by Meunier. Osteoporotic patients with trabecular bone volume under the vertebral crush threshold had a significant decrease in all trabecular parameters. On the opposite, patients with trabecular bone volume above the vertebral crush threshold had only a significant decrease in the number of trabeculae. A negative correlation was found between age and plate density in both osteoporotic patients and controls. A linear correlation was found between trabecular bone volume and plate density, but thickness and density of trabecular plates were not correlated. This study confirms that involutional osteoporosis is not only a decreased bone mass disorder. A modified spatial distribution of trabeculae or a mechanically less resistant bone matrix could be additional factors.  相似文献   

10.
《Journal of biomechanics》2014,47(16):3830-3836
The first aim of this study was to assess displacements and micro-strain induced on different grades of atrophic cortical and trabecular mandibular bone by axially loaded dental implants using finite element analysis (FEA). The second aim was to assess the micro-strain induced by different implant geometries and the levels of bone-to-implant contact (BIC) on the surrounding bone. Six mandibular bone segments demonstrating different grades of mandibular bone atrophy and various bone volume fractions (from 0.149 to 0.471) were imaged using a micro-CT device. The acquired bone STL models and implant (Brånemark, Straumann, Ankylos) were merged into a three-dimensional finite elements structure. The mean displacement value for all implants was 3.1±1.2 µm. Displacements were lower in the group with a strong BIC. The results indicated that the maximum strain values of cortical and cancellous bone increased with lower bone density. Strain distribution is the first and foremost dependent on the shape of bone and architecture of cancellous bone. The geometry of the implant, thread patterns, grade of bone atrophy and BIC all affect the displacement and micro-strain on the mandible bone. Preoperative finite element analysis could offer improved predictability in the long-term outlook of dental implant restorations.  相似文献   

11.
Understanding of cancellous bone permeability is lacking despite its importance in designing tissue engineering scaffolds for bone regeneration and orthopaedic surgery that relies on infiltration of bone cement into porous cancellous bone. We employed micro-computational fluid dynamics to investigate permeability for 37 cancellous bone specimens, eliminating stringent technical requirements of bench-top testing. Microarchitectural parameters were also determined for the specimens and correlated, using uni-variate and multi-variate regression analyses, against permeability. We determined that bone surface density, trabecular pattern factor, structure model index and trabecular number are other possible predictors of permeability (with R values of 0.47, 0.44, 0.40 and 0.33), in addition to the commonly used porosity parameter (R value of 0.38). Pooling these parameters and performing multi-variate linear regression analysis improved yield the R-value of 0.50, indicating that porosity alone is a poor predictor of cancellous bone permeability and, therefore, other parameters should be included for a better and improved linear model.  相似文献   

12.

Background

Several agents are available to treat osteoporosis while addressing patient-specific medical needs. Individuals'' residual risk to severe fracture may require changes in treatment strategy. Data at osseous cellular and microstructural levels due to a therapy switch between agents with different modes of action are rare. Our study on a series of five consecutively taken bone biopsies from an osteoporotic individual over a six-year period analyzes changes in cellular characteristics, bone microstructure and mineralization caused by a therapy switch from an antiresorptive (bisphosphonate) to a dual action bone agent (strontium ranelate).

Methodology/Principal Findings

Biopsies were progressively taken from the iliac crest of a female patient. Four biopsies were taken during bisphosphonate therapy and one biopsy was taken after one year of strontium ranelate (SR) treatment. Furthermore, serum bone markers and dual x-ray absorptiometry measurements were acquired. Undecalcified histology was used to assess osteoid parameters and bone turnover. Structural indices and degree of mineralization were determined using microcomputed tomography, quantitative backscattered electron imaging, and combined energy dispersive x-ray/µ-x-ray-fluorescence microanalysis.

Conclusions/Significance

Microstructural data revealed a notable increase in bone volume fraction after one year of SR treatment compared to the bisphosphonate treatment period. Indices of connectivity density, structure model index and trabecular bone pattern factor were predominantly enhanced indicating that the architectural transformation from trabecular rods to plates was responsible for the bone volume increase and less due to changes in trabecular thickness and number. Administration of SR following bisphosphonates led to a maintained mineralization profile with an uptake of strontium on the bone surface level. Reactivated osteoclasts designed tunneling, hook-like intratrabecular resorption sites. The appearance of tunneling resorption lacunae and the formation of both mini-modeling units and osteon-like structures within increased plate-like cancellous bone mass provides additional information on the mechanisms of strontium ranelate following bisphosphonate treatment, which may deserve special attention when monitoring a treatment switch.  相似文献   

13.
Understanding of cancellous bone permeability is lacking despite its importance in designing tissue engineering scaffolds for bone regeneration and orthopaedic surgery that relies on infiltration of bone cement into porous cancellous bone. We employed micro-computational fluid dynamics to investigate permeability for 37 cancellous bone specimens, eliminating stringent technical requirements of bench-top testing. Microarchitectural parameters were also determined for the specimens and correlated, using uni-variate and multi-variate regression analyses, against permeability. We determined that bone surface density, trabecular pattern factor, structure model index and trabecular number are other possible predictors of permeability (with R values of 0.47, 0.44, 0.40 and 0.33), in addition to the commonly used porosity parameter (R value of 0.38). Pooling these parameters and performing multi-variate linear regression analysis improved yield the R-value of 0.50, indicating that porosity alone is a poor predictor of cancellous bone permeability and, therefore, other parameters should be included for a better and improved linear model.  相似文献   

14.
Analysis of stresses and strains in bone tissues and simulation of their adaptive remodelling require exhaustive information about distribution of constitutive properties of cancellous bone and their relationships to microstructural parameters. Homogenization of "equivalent" trabecular microstructures appears to be an advantageous tool for this task. In this study, parameterized orthotropic constitutive models of cancellous bone are derived from finite element analysis of repeatable microstructure cells. The models, based on a space-filling dodecahedron, are fully three-dimensional and are parameterized with four shape parameters. Variation of the parameters allows to imitate most of typical microstructure patterns observed in real bones, along with a variety of intermediate geometries. Finite element models of cells are generated by a special-purpose structured mesh generator for any arbitrary set of shape parameter values. Static numerical tests are performed for an exhaustive number of parameter value sets (microstructure instances). Coefficients of elastic orthotropic stiffness matrix are determined as tabularized functions of elastic constants versus the shape parameters. Additionally, they are correlated to apparent density and principal fabric tensor values. Comparison of the results with micro-FE data obtained for a large set of cancellous bone specimens proves a good agreement.  相似文献   

15.
Abstract: The dinosaur Stegosaurus is characterized by osteoderms of alternating plates and terminal paired spikes. Previous studies have described the histological features and possible functions of these osteoderms. However, ontogenetic changes are poorly documented. In this study, the ontogenetic changes of the osteoderms are examined using eight different ontogenetic skeletons (a juvenile, a subadult, a young adult, and five old adults based on the cortical histology of their body skeletons). The juvenile plate and subadult spike show thin cortex and thick cancellous bone. The young adult plates have an extensive vascular network, which is also seen in old adults. Old adult spikes are different from old adult plates in having a thick cortex and a large axial channel. The cortical histology, in both plates and spikes, show well‐vascularized bone tissue consisting of dense mineralized fibres in young adult forms. In old adult forms, the bone tissues in the spikes become more compact and are extensively remodelled. This might contribute to the structural reinforcement of the spikes. The plates in old adult forms also show extensive remodelling and lines of arrested growth, but only limited signs of compaction. The timing for acquisition of features seen in old adults is different between plates (an extensive vascular network in the young adult) and spikes (a thick cortex with a large axial channel in old adults). The result suggests that the timing for plate and spike functions is different. The extensive vascular networks seen in large plates suggest their function is for display and/or thermoregulation. The thick cortical bone of spikes of old adults suggests that spikes acquire a weapon function for defence ontogenetically late.  相似文献   

16.
The fine structure of Gnathostomulid reproductive organs   总被引:1,自引:0,他引:1  
Summary The male copulatory organs of five species of Gnathostomulida Scleroperalia have been studied by TEM techniques. These observations provide a more solid basis for classification in the light microscope: inLabidognathia longicollis (fam. Mesognathariidae) the stylet is composed of eight, and inSemaeognathia sterreri, Gnathostomula jenneri, Gnathostomula mediterranea andGnathostomula microstyla (Gnathostomulidae) of ten stylet rods. Each rod consists of a microtubule-filled inner rod, and of an outer rod, filled with crystallized inclusions. The inner rods are continuous with eight — or ten — rod formation cells which are located in the proximal stylet sack. Bipartition of rods occurs by a longitudinal invagination of the basement lamina, underlying the rod cells and the gland cells and continuous with that of the body wall epithelium. InLabidognathia, the outer rods are interlocked, in Gnathostomulidae, the stylet rods are surrounded by an extracellular (cuticular) tube-like stylet sheath of variable fine structure, which is believed to provide extra rigidity. In the species investigated, one single stylet gland, consisting of a monolayered epithelium showing different gland cell types, surrounds the stylet. In the apical gland cell portions, medially and distally membrane-bound secretory granules lie adjacent to the stylet sheath. In Gnathostomulidae, two anterior gland cells are seen in connection with the formation of the stylet sheath. In the muscular sheath the cross-striated fibers, basically derived from the longitudinal body wall musculature, show a tendency towards helical and circumferential arrangement. Musculature is especially prominent in the proximal stylet sack, which is rather a propulsive element than a sperm-storing vesicle, and lacks glands. InGnathostomula species, atrial cells underlie the distal tip of the stylet. The entrance into the male opening is lined with ciliary receptor cells and specialized gland cells.Stylet evolution in Scleroperalia is characterized by progressive differentiation of the muscular sheath, in particular of the proximal stylet sack, and of the stylet — the occurrence of a stylet sheath is seen in connection with increasing diversity of stylet shape.Abbreviations ac atrial cell(s) - ag anterior gland cell(s) - b bursa - bl basal lamina - c rod-crystal in outer rod - cj cuticle of jaw - d desmosome - di dictyosome - e body wall epithelium - ej pharyngeal epithelium - g stylet gland (cell) - gm median gland cell - i gut (cell) - ir inner rod - jc junctional complex - m muscular layer - mo male opening - mv microvillar protrusions - nu nucleus - o ovary - or outer rod - po proximal opening of the proximal stylet sack - ps proximal stylet sack - r stylet rod - rc rod cell - sg secretory granule - sj septate junction - sp sperm - ss stylet sheath - st stylet - te testes - v ventral - z centriole  相似文献   

17.
目的:在骨组织工程中,如何制备出理想的支架材料一直是研究重点;目前主要的有天然生物支架材料、人工合成有机材料和无机材料等;生物衍生骨即天然生物支架材料的一种,由于其与天然骨在形态结构上较为相似,是近年来研究较多的支架材料之一;既往形态学研究局限于在二维层面,对于其三维结构参数分析较少。故本实验主要运用Micro-CT对生物衍生松质骨的三维结构参数进行分析,量化评价其作为骨组织工程支架材料的结构参数。方法:截取新鲜猪松质骨,经脱脂脱蛋白部分脱钙及去抗原处理后,制作成生物衍生骨支架;应用Micro.CT扫描,重建三维图并量化分析其结构参数,统计软件SPSS分析各参数间的相关性。结果:经Micro.CT扫描,得到二维CT图和三维重建图。各三维结构参数的值分别为:BV/TV(20.48±5.14)%;BS/BV(41.66±5.39)1/ram;Porosity(79.52±5.14)%;Tb.Th(0.10±0.01)mm;Tb.N(1.99±0.47)l/mm;Tb.Sp(0.32±0.05)mm;Tb.Pf(2.03±4.70)1/mm;SMI(1.28±0.35);DA(1.60±0.23);Corm.Dn(158.53±106.09)I/mm3。各参数间相关系数具有统计学意义的为:(1)Porosity与BS/BV、Tb.Th;(2)BV/TV与BS/BV、Tb.Th;(3)BS/BV与Coma.Dn、Porosity、BV/TV、;(4)Tb.Th与Porosity、BV厂IV、Conn.Dn;(5)DA与Corm.Dn;(6)Conn.Dn与Bs/BV、Tb.Th、DA。结论:Micro-CT扫描、量化分析是评价支架材料结构参数的理想方法;也证明生物衍生骨支架符合骨组织工程对支架材料的三维结构要求,尤其在孔径大小、孔隙率、表面积体积比等三维结构参数,此外,也可为其他支架材料的制备在三维结构上的要求提供参考依据。  相似文献   

18.
There are substantial changes in maternal skeletal dynamics during pregnancy, lactation, and after lactation. The purpose of this study was to correlate changes in cortical and cancellous bone mass, structure, and dynamics with mechanical properties during and after the first reproductive cycle in rats. Rats were mated and groups were taken at parturition, end of lactation and 8 wk after weaning, and were compared with age-matched, nulliparous controls. Measurements were taken on femoral cortical bone and lumbar vertebral body cancellous bone. At the end of pregnancy, there was an increase in cortical periosteal bone formation and an increase in cortical volume, but a suppression of turnover in cancellous bone with no change in cancellous or cortical mechanical properties. Lactation was associated with a decrease in cortical and cancellous bone strength with a decrease in bone volume, but an increase in turnover on cancellous and endocortical surfaces. After lactation, there was a partial or full restoration of mechanical properties. This study demonstrates substantial changes in bone mechanics that correlate with changes in bone structure and dynamics during the first reproductive cycle in rats. The greatest changes were observed during the lactation period with partial or full recovery in the postlactational period.  相似文献   

19.
The current study was designed to investigate the skeletal effects of alfacalcidol in aged rats. Eighteen-month-old male rats were treated with 0, 0.1, or 0.2 microg/kg/d of alfacalcidol by daily oral gavage, 5 days/week for 12 weeks. At the beginning of the treatments, one group of rats was euthanized to serve as a baseline control. At the end of the study, the second lumbar vertebrae and the right tibial diaphysess were processed for bone histomorphometric analysis. The fourth lumbar vertebrae were subjected to strength testing. The control group of rats at 21 months of age had decreased serum testosterone levels and decreased cancellous bone mass associated with increased bone turnover on the trabecular surface. The older rats had increased bone turnover on the endocortical surface and decreased bone formation on the periosteal surface compared with the 18-month group. In contrast, alfacalcidol treatment increased cancellous and cortical bone mass in aged male rats. Trabecular bone resorption was decreased whereas bone formation was maintained or increased in the rats treated with alfacalcidol. In addition, endocortical bone formation was decreased whereas periosteal bone formation was increased in the rats treated with alfacalcidol compared with vehicle-treated rats. Marrow trabecular bone area was increased by alfacalcidol treatment in tibial diaphyses. Furthermore, bone strength of the lumbar vertebral body was increased after alfacalcidol treatment. An atypical pattern of bone formation on endosteal bone surfaces was seen in the rats treated with alfacalcidol. The atypical bone formation is characterized by small, focal packets of newly formed bone on trabecular and endocortical bone surfaces. This gave the appearance of the formation of "bone buds" emanating from trabecular surfaces. These bony outgrowths were mineralized and demonstrated significant fluorochrome label indicating recent mineralization. Also, lamellae of the bony buds did not run parallel to those of the trabecular plate to which they are attached. Arrest lines presented in most of the "bone buds". In summary, alfacalcidol treatment increased cancellous and cortical bone mass and improved bone strength, resulting in the prevention of age-related bone loss in aged male rats. An atypical pattern of bone formation observed in this study may be a result of minimodeling based bone formation stimulated by alfacalcidol treatment.  相似文献   

20.
Water is commonly removed from bone to study its effect on mechanical behaviour; however, dehydration also alters the bone structure. To make matters worse, measuring structural changes in cancellous bone is complicated by a number of factors. Therefore, the goals of this study were to address these issues by (1) comparing Archimedes' method and a helium pycnometer as methods for measuring cancellous bone volume; (2) measuring the apparent dimensional and volumetric tissue shrinkage of cancellous bone at two levels of dehydration; and, (3) identifying whether a size effect exists in cancellous bone shrinkage. Cylindrical specimens (3, 5 and 8.3 mm diameters) of cancellous bone were taken from the distal bovine femur. The apparent dimensions of each cylindrical specimen were measured in a fully hydrated state (HYD), after drying at room temperature (AIR), and after oven drying at 105 degrees C (OVEN). Tissue volume measurements for those three hydration states were obtained using both a helium pycnometer and Archimedes' method. Aluminium foams, which mimic the cancellous structure, were used as controls. The results suggest that the helium pycnometer and Archimedes' method yield identical results in the HYD and AIR states, but that Archimedes' method under-predicts the nominal OVEN volume by incorporating the collagen-apatite porosity. A distinct size effect on volumetric shrinkage is observed (p<0.025) using the pycnometer in both AIR and OVEN states. Apparent dimensional shrinkage (2% and 7%) at the two dehydration levels is much smaller than the measured volumetric tissue shrinkage (16% and 29%), which results in a reduced dehydrated bone volume fraction.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号