 共查询到20条相似文献,搜索用时 281 毫秒
1.
A numerical simulation of the transport of light energy in the near infrared region of the spectrum through human brain tissue is presented. This simulation models the use of near infrared spectroscopic techniques to quantify the levels of oxygen present in brain tissue. Successful application of the technique requires knowledge of the optical pathlength in the tissue, and it is the goal of this simulation to quantify the relationship of the optical pathlength and the oxygenation state of the tissue. Both implicit and explicit finite element schemes for unstructured grids are implemented and discussed. Several application simulations using three tissue grids of varying degrees of physiological accuracy are then conducted, and figures for the optical pathlength of light through the tissue at varying levels of oxygenation are computed. These results are then used to develop a quantitative relationship between the pathlength and the absorption parameter for the three tissue models which we explore.  相似文献   

2.
Understanding near infrared light propagation in tissue is vital for designing next generation optical brain imaging devices. Monte Carlo (MC) simulations provide a controlled mechanism to characterize and evaluate contributions of diverse near infrared spectroscopy (NIRS) sensor configurations and parameters. In this study, we developed a multilayer adult digital head model under both healthy and clinical settings and assessed light‐tissue interaction through MC simulations in terms of partial differential pathlength, mean total optical pathlength, diffuse reflectance, detector light intensity and spatial sensitivity profile of optical measurements. The model incorporated four layers: scalp, skull, cerebrospinal‐fluid and cerebral cortex with and without a customizable lesion for modeling hematoma of different sizes and depths. The effect of source‐detector separation (SDS) on optical measurements' sensitivity to brain tissue was investigated. Results from 1330 separate simulations [(4 lesion volumes × 4 lesion depths for clinical +3 healthy settings) × 7 SDS × 10 simulation = 1330)] each with 100 million photons indicated that selection of SDS is critical to acquire optimal measurements from the brain and recommended SDS to be 25 to 35 mm depending on the wavelengths to obtain optical monitoring of the adult brain function. The findings here can guide the design of future NIRS probes for functional neuroimaging and clinical diagnostic systems.   相似文献   

3.
Through the use of a picosecond laser pulse of near-infrared light at 1,064 nm, the temporal profile of the transmitted light through the anesthetized rat head has been investigated. The light intensity at a certain time after the input pulse was exponentially attenuated by the hemoglobin concentration with hematocrit values from 1.5 to 50%, although the transmitted pulse broadened markedly due to scattering by the cerebral tissue. The optical pathlength, which is required for quantitation of the absolute absorbance change, was directly determined, by the time of flight measurement of the light pulses, as the product of the velocity of light in tissue and time. The mean concentration of hemoglobin in the brain could be determined quantitatively by the use of this pathlength. The oxygen saturation of venous blood determined by our time of flight measurement was very close to that in the internal jugular vein determined directly with a gas analyzer. Thus, the picosecond laser technique is useful for quantifying the blood oxygenation in tissues.  相似文献   

4.
Near infrared (IR) spectroscopy can give continuous, direct information about cerebral oxygenation in vivo by providing signals from oxygenated and deoxygenated haemoglobin and cytochrome aa3. Due to a lack of precise spectral information and uncertainties about optical path length it has previously been impossible to quantify the data. We have therefore obtained the cytochrome aa3 spectrum in vivo from the brains of rats after replacing the blood with a fluorocarbon substitute. Near infrared haemoglobin spectra were also obtained, at various oxygenation levels, from cuvette studies of lysed human red blood cells. Estimates of optical path length have been obtained. The data were used to construct an algorithm for calculating the changes in oxygenated and deoxygenated haemoglobin and oxygenated cytochrome aa3 in tissue from changes in near IR absorption.  相似文献   

5.
To determine the alterations in optical characteristics and cerebral blood oxygenation (CBO) during activation and deactivation, we evaluated the changes in mean optical pathlength (MOP) and CBO induced by a verbal fluency task (VFT) and driving simulation in the right and left prefrontal cortex (PFC), employing a newly developed time-resolved near infrared spectroscopy, which allows quantitative measurements of the evoked-CBO changes by determining the MOP with a sampling time of 1 s. The results demonstrated differences in MOP in the foreheads with the subjects and wavelength; however, there was no significant difference between the right and left foreheads (p > 0.05). Also, both the VFT and driving simulation task did not affect the MOP significantly as compared to that before the tasks (p > 0.05). In the bilateral PFCs, the VFT caused increases of oxyhemoglobin and total hemoglobin associated with a decrease of deoxyhemoglobin, while the driving simulation task caused decreases of oxyhemoglobin and total hemoglobin associated with an increase of deoxyhemoglobin; there were no significant differences in evoked-CBO changes between the right and left PFC. The present results will be useful for quantitative measurement of hemodynamic changes during activation and deactivation in the adults by near infrared spectroscopy.  相似文献   

6.
A method that provides maps of absolute concentrations of oxygenated and deoxygenated myoglobin (Mb), its oxygenation, and its near-infrared (NIR) optical pathlength in cardiac tissue was developed. These parameters are available simultaneously. The method is based on NIR diffuse reflectance spectroscopic imaging and specific processing of the NIR images, which included a first derivative of the diffuse reflectance spectrum. Mb oxygenation, total Mb concentration, and NIR light pathlength were found to be in the range of 92%, 0.3 mM, and 12.5 mm, respectively, in beating isolated buffer-perfused and arrested pig hearts. The charge-coupled device camera enables sub-millimeter spatial resolution and spectroscopic imaging in 1.5 to 2.0 min. The technique is noninvasive and nondestructive. The equipment has no mechanical contact with the tissue of interest, leaving it undisturbed.  相似文献   

7.
The recent development of near-infrared time- and frequency-resolved tissue spectroscopy techniques to probe tissue oxygenation and tissue oxygenation kinetics has led to the need for further quantitation of spectroscopic signals. In this paper, we briefly review the theory of light transport in strongly scattering media as monitored in the time and frequency domains, and use this theory to develop algorithms for quantitation of hemoglobin saturation from the photon decay rate (delta log R/delta t) obtained using time-resolved spectroscopy, and from the phase-shift (theta) obtained from frequency-resolved, phase-modulated spectroscopy. To test the relationship of these optical parameters, we studied the behavior of delta log R/delta t and theta as a function of oxygenation in model systems which mimicked the optical properties of tissue. Our results show that deoxygenation at varying hemoglobin concentrations can be monitored with the change in the photon decay kinetics, delta delta log R/delta t in the time-resolved measurements, and with the change in phase-shift, delta theta, in the frequency-resolved technique. Optical spectra of the adult human brain obtained with these two techniques show similar characteristics identified from the model systems.  相似文献   

8.

Background and Objective

Low level light therapy has garnered significant interest within the past decade. The exact molecular mechanisms of how red and near infrared light result in physiologic modulation are not fully understood. Heme moieties and copper within cells are red and near infrared light photoreceptors that induce the mitochondrial respiratory chain component cytochrome C oxidase, resulting in a cascade linked to cytoprotection and cellular metabolism. The copper centers in cytochrome C oxidase have a broad absorption range that peaks around 830 nm. Several in vitro and in vivo animal and human models exist that have demonstrated the benefits of red light and near infrared light for various conditions. Clinical applications for low level light therapy are varied. One study in particular demonstrated improved durable functional outcomes status post-stroke in patients treated with near infrared low level light therapy compared to sham treatment [1]. Despite previous data suggesting the beneficial effect in treating multiple conditions, including stroke, with low level light therapy, limited data exists that measures transmission in a human model.

Study Design/Materials and Methods

To investigate this idea, we measured the transmission of near infrared light energy, using red light for purposes of comparison, through intact cadaver soft tissue, skull bones, and brain using a commercially available LED device at 830 nm and 633 nm.

Results

Our results demonstrate that near infrared measurably penetrates soft tissue, bone and brain parenchyma in the formalin preserved cadaveric model, in comparison to negligible red light transmission in the same conditions.

Conclusion

These findings indicate that near infrared light can penetrate formalin fixed soft tissue, bone and brain and implicate that benefits observed in clinical studies are potentially related to direct action of near infrared light on neural tissue.  相似文献   

9.
To noninvasively determine absolute concentrations of hemoglobin (Hb) plus myoglobin (Mb) in cardiac tissue by means of regular near infrared (NIR) light diffuse reflectance measurements, a first derivative approach was applied. The method was developed to separately calculate oxygenated and deoxygenated [Hb + Mb] as well as an effective pathlength, which NIR light passes through in the tissue between optodes. Applying a cotton wool-based phantom, which mimics muscle tissue, it was shown that the intensity of the pseudo-optical density first derivative depends linearly on both oxygenated and deoxygenated Hb concentration, thereby validating the Lambert-Beer law in the range of 0 to 0.25 mM tetrameric Hb. A high correlation (R = 0.995) was found between concentrations of Hb loaded onto the phantom and those determined spectrophotometrically, thereby verifying the first derivative method validity. The efficiency of the method was tested using in vivo pig hearts prior to and after ischemia initiated experimentally by left anterior descending artery branches occlusion. The results showed that the total [Hb + Mb] was 0.9-1.2 mM heme, the average tissue oxygen saturation was approximately 70% (which reduced to nearly 0% after occlusion), and the NIR (700-965 nm) light pathlength was 2.3 mm (differential pathlength factor [DPF] = 2.7-2.8) in a living heart tissue.  相似文献   

10.
The effects of tissue optical absorbance on intracellular NAD(P)H and Indo-1 fluorescence emission have been evaluated in the perfused rabbit heart. These results demonstrate that the tissue optical absorbance significantly modifies the emission characteristics of these fluorophores. This tissue 'inner filter' effect, observed with both probes, changed as a function of tissue oxygenation and redox state in a wavelength-dependent manner. Pathlength calculations from these results indicate that this inner filter effect could occur with a mean pathlength of 310 microns due to the extremely high extinction coefficient of heart tissue. It is concluded that tissue optical absorbance significantly affects the fluorescent emission characteristics of both intrinsic and extrinsic probes in the intact heart, under a variety of conditions. Several potential methods of correcting for these tissue inner filter effects are discussed.  相似文献   

11.
In this paper, near‐infrared spectroscopy (NIRS) and jumping optical tweezers were used to measure the tissue oxygenation and the elasticity of erythrocytes, respectively. The correlation between tissue oxygenation induced by arterial occlusion test (AOT) and the mechanical properties of individual erythrocytes from a blood sample obtained after AOT was studied. The experimental results show a linear correlation between the oxygenation signal caused by AOT and the elasticity of erythrocytes. (© 2011 WILEY‐VCH Verlag GmbH & Co. KGaA, Weinheim)  相似文献   

12.
近红外光谱技术在运动脑功能研究中的应用   总被引:1,自引:0,他引:1  
近红外光谱是一种评估生物组织氧合水平的无创性光学技术,这一技术以血液动力学原理为基础,能实时监测局部脑区的动态变化。近红外光谱作为一种客观的测量工具,在人体运动科学领域广泛运用。近红外光谱技术可用于区别体能水平、监控耐力训练和抗阻训练过程特征以及考察运动中的认知活动变化。本文综述了近红外光谱技术原理及其在抗阻运动、运动中枢疲劳和运动认知领域的运用,并对近红外光谱在运动科学领域的未来研究趋向作了分析。  相似文献   

13.
A novel setup for the efficient constant optical measurements of biological tissues in the near infrared is presented. The system combines the use of a fiber‐based supercontinuum source with a simple optics fiber collimator. This configuration allows a wide spectral range of measurement and, at the same time, can efficiently filter the straightforward transmitted light while avoiding scattered light. As a performance example, the optical characterization of rat brain and retina tissues are shown. The attenuation coefficient for both tissues in the near infrared region is also obtained. This technique could be applied in clinical research as a noninvasive method with several potential practical applications.  相似文献   

14.
Accurate assessment of cutaneous tissue oxygenation and vascular function is important for appropriate detection, staging, and treatment of many health disorders such as chronic wounds. We report the development of a dual-mode imaging system for non-invasive and non-contact imaging of cutaneous tissue oxygenation and vascular function. The imaging system integrated an infrared camera, a CCD camera, a liquid crystal tunable filter and a high intensity fiber light source. A Labview interface was programmed for equipment control, synchronization, image acquisition, processing, and visualization. Multispectral images captured by the CCD camera were used to reconstruct the tissue oxygenation map. Dynamic thermographic images captured by the infrared camera were used to reconstruct the vascular function map. Cutaneous tissue oxygenation and vascular function images were co-registered through fiduciary markers. The performance characteristics of the dual-mode image system were tested in humans.  相似文献   

15.
Physical model simulations of brain injury in the primate   总被引:20,自引:0,他引:20  
Diffuse brain injuries resulting from non-impact rotational acceleration are investigated with the aid of physical models of the skull-brain structure. These models provide a unique insight into the relationship between the kinematics of head motion and the associated deformation of the surrogate brain material. Human and baboon skulls filled with optically transparent surrogate brain tissue are subjected to lateral rotations like those shown to produce diffuse injury to the deep white matter in the brain of the baboon. High-speed cinematography captures the deformations of the grids embedded within the surrogate brain tissue during the applied load. The overall deformation pattern is compared to the pathological portrait of diffuse brain injury as determined from animal studies and autopsy reports. Shear strain and pathology spatial distributions mirror each other. Load levels and resulting surrogate brain tissue deformations are related from one species to the other. Increased primate brain mass magnified the strain amplified without significantly altering the spatial distribution. An empirically-derived value for a critical shear strain associated with the onset of severe diffuse axonal injury in primates is determined, assuming constitutive similarity between baboon and human brain tissue. The primate skull physical model data and the critical shear strain associated with the threshold for severe diffuse axonal injury were used to scale data obtained from previous studies to man, and thus derive a diffuse axonal injury tolerance for rotational acceleration for humans.  相似文献   

16.
The purpose of this paper is to demonstrate that near‐infrared (NIR) spectroscopic imaging can provide spatial distribution (maps) of the absolute concentration of hemoglobin + myoglobin, oxygen saturation parameter and optical pathlength, reporting on the biochemico‐physiological status of a beating heart in vivo. The method is based on processing the NIR spectroscopic images employing a first‐derivative approach. Blood‐pressure‐controlled gating compensated the effect of heart motion on the imaging. All the maps are available simultaneously and noninvasively at a spatial resolution in the submillimeter range and can be obtained in a couple of minutes. The equipment has no mechanical contact with the tissue, thereby leaving the heart unaffected during the measurement. (© 2012 WILEY‐VCH Verlag GmbH & Co. KGaA, Weinheim)  相似文献   

17.
If gold nanorods are used as photoabsorbers, then light in the near infrared tissue window can generate a strong photothermal effect. In this issue, C. Paviolo et al. show that near infrared light can be used to evoke a calcium response in neuronal cells treated with gold nanorods. This suggests new opportunities for peripheral nerve regeneration and infrared neural stimulation. (Picture: C. Paviolo et al., pp. 761–765 in this issue)  相似文献   

18.
金纳米棒具有独特的光学性质、表面易修饰性、较低的生物毒性和良好的生物相容性,因而在成像、光热治疗和药物载带等方面具有极高的潜在应用价值.本文综述了典型的金纳米棒表面修饰方法及其在生物成像、光热治疗和药物治疗中的应用,重点阐述了通过金纳米棒同时实现肿瘤诊断和治疗相结合的研究进展.  相似文献   

19.
Clinicians need a way to rapidly and reliably test the correct functioning of near‐infrared spectroscopy (NIRS)–based oximeters. Therefore, optical phantoms for quality assessment of NIRS oximeters are needed. The fabrication of such phantoms that mimic the optical properties of biological tissue in the NIR range represents a challenge. To enable their development, the aim was to characterize the absorption and scattering spectra of different dyes. The optical properties of silicone SILPURAN 2420 with 11 color pastes of type ELASTOSIL were measured in the 500 to 1000 nm range by a spectrometer with an integrating sphere. In addition, two commercial frequency‐domain NIRS devices, the ISS OxiplexTS and the ISS Imagent, were used to assess the optical properties at specific wavelengths. The evaluated colors present mostly features in the visible range below 650 nm, but two colors include peaks in the near‐infrared region, simulating low tissue oxygenation values. These colors were used to create an optical phantom, which matched the designed StO2 value within an error of only 4%. This set of dyes already enables simulating many different spectra, thus achieving a first step on the way to a long‐term stable comparison and validation method.   相似文献   

20.
基于相关检测的多通道近红外光组织光学测量系统   总被引:2,自引:0,他引:2  
研制了一套基于相关检测技术的三波长多通道近红外光信号采集系统。采用相敏检波模块CD505R有效提高信噪比。Delphi开发的上位机程序通过串口方式与单片机通信。使用光纤传递光源及探测信号,使系统具有更大的灵活性,适用于多种组织光学特性测量方式。模型实验的结果证明该系统准确可靠,前臂阻断实验表明系统对不同深度组织血氧状况具有较好的测量能力。  相似文献   