1.
Rationale and Objectives. To reduce tibio-femoral misalignment, the polyethylene bearing-component of a new knee prosthesis was allowed limited motion on the underlying metallic component. The object of the work presented here was to develop a suitable radiographic technique for quantifying the in-vivo position of the bearing. By collecting these data at discrete flexion angles, the functional operation of the prosthesis could be determined

Methods. The known geometries between landmarks on the two components were used to produce algorithms for reconstructing their spatial positions from a single radiograph. A custom-designed computer program utilized these algorithms to determine the relative translation and rotation of the polyethylene component

Results. This technique produced typical errors of 0.54 mm translation and 0.56° rotation between the polyethylene component and the underlying metallic component

Conclusions. A practical method has been developed for assessing mobile-bearing motion, in vivo. This method can be applied to other prosthetic devices, or combinations of components, once the requirement for identifiable landmarks has been addressedClinical Relevance. Skeletal and soft-tissue changes in the pathological knee may produce abnormal rotations and translations in the transverse tibial plane. This technique is intended both to validate the design philosophy of a mobile-bearing prosthesis and to provide additional data on any pathological motions, which will have implications for future prosthetic designs.  相似文献   

2.
The hypothesis of this study was that the polyethylene bearing in a rotating platform total knee prosthesis shows axial rotation during a step-up motion, thereby facilitating the theoretical advantages of mobile-bearing knee prostheses. We examined 10 patients with rheumatoid arthritis who had a rotating platform total knee arthroplasty (NexGen LPS mobile, Zimmer Inc. Warsaw, USA). Fluoroscopic data was collected during a step-up motion six months postoperatively. A 3D-2D model fitting technique was used to reconstruct the in vivo 3D kinematics. The femoral component showed more axial rotation than the polyethylene mobile-bearing insert compared to the tibia during extension. In eight knees, the femoral component rotated internally with respect to the tibia during extension. In the other two knees the femoral component rotated externally with respect to the tibia. In all 10 patients, the femur showed more axial rotation than the mobile-bearing insert indicating the femoral component was sliding on the polyethylene of the rotating platform during the step-up motion. Possible explanations are a too limited conformity between femoral component and insert, the anterior located pivot location of the investigated rotating platform design, polyethylene on metal impingement and fibrous tissue formation between the mobile-bearing insert and the tibial plateau.  相似文献   

3.
Skin marker-based motion analysis has been widely used in biomechanical studies and clinical applications. Unfortunately, the accuracy of knee joint secondary motions is largely limited by the nonrigidity nature of human body segments. Numerous studies have investigated the characteristics of soft tissue movement. Utilizing these characteristics, we may improve the accuracy of knee joint motion measurement. An optimizer was developed by incorporating the soft tissue movement patterns at special bony landmarks into constraint functions. Bony landmark constraints were assigned to the skin markers at femur epicondyles, tibial plateau edges, and tibial tuberosity in a motion analysis algorithm by limiting their allowed position space relative to the underlying bone. The rotation matrix was represented by quaternion, and the constrained optimization problem was solved by Fletcher's version of the Levenberg-Marquardt optimization technique. The algorithm was validated by using motion data from both skin-based markers and bone-mounted markers attached to fresh cadavers. By comparing the results with the ground truth bone motion generated from the bone-mounted markers, the new algorithm had a significantly higher accuracy (root-mean-square (RMS) error: 0.7 ± 0.1 deg in axial rotation and 0.4 ± 0.1 deg in varus-valgus) in estimating the knee joint secondary rotations than algorithms without bony landmark constraints (RMS error: 1.7 ± 0.4 deg in axial rotation and 0.7 ± 0.1 deg in varus-valgus). Also, it predicts a more accurate medial-lateral translation (RMS error: 0.4 ± 0.1 mm) than the conventional techniques (RMS error: 1.2 ± 0.2 mm). The new algorithm, using bony landmark constrains, estimates more accurate secondary rotations and medial-lateral translation of the underlying bone.  相似文献   

4.
Fluoroscopy has recently been used to analyze postoperative kinematics in total knee arthroplasty (TKA). These analyses have reported varying results even in patients with similar implant design. In addition, patterns of wear in retrieved tibial polyethylene inserts of similar design have been found to vary substantially. These findings suggest that surgical technique, especially soft tissue balancing, may play a role in postoperative kinematics and implant failure. Accurate soft-tissue balancing is hypothesized to result in similar pressures within the medial and lateral compartments of the knee. However, a method of easily measuring these pressures at TKA has not been developed. In the present study, 32 patients were implanted with a mobile-bearing LCS TKA utilizing the balanced gap technique. An electronic pressure sensor, developed specifically to record pressure magnitude and distribution in the medial and lateral compartments, was incorporated into the implant trials. The knee was then passively taken through a range of motion while pressure data was recorded via computer. Postoperatively, 16 patients underwent active fluoroscopic kinematic analysis to assess for condylar liftoff and femorotibial translation. We found that abnormal compartment pressures and distributions as recorded by the intraoperative pressure sensor were correlated with inappropriate or paradoxical postoperative kinematics. In addition, subjects having similar pressures in both compartments throughout a range of motion did not experience condylar liftoff values greater than 1.0 mm. These data suggest that surgical technique influences the magnitude and distribution of forces at the articulation, postoperative kinematics, and likely, implant longevity.  相似文献   

5.
Debris-induced osteolysis due to surface wear of ultra high molecular weight polyethylene (UHMWPE) bearings is a potential long-term failure mechanism of total knee replacements (TKR). This study investigated the effect of prosthesis design, kinematics and bearing material on the wear of UHMWPE bearings using a physiological knee simulator. The use of a curved fixed bearing design with stabilised polyethylene bearings reduced wear in comparison to more flat-on-flat components which were sterilised by gamma irradiation in air. Medium levels of crosslinking further improved the wear resistance of fixed bearing TKR due to resistance to strain softening when subjected to multidirectional motion at the femoral-insert articulating interface. Backside motion was shown to be a contributing factor to the overall rate of UHMWPE wear in fixed bearing components. Wear of fixed bearing prostheses was reduced significantly when anterior-posterior displacement and internal-external rotation kinematics were reduced due to decreased cross shear on the articulating surface and a reduction in AP displacement. Rotating platform mobile bearing prostheses exhibited reduced wear rates in comparison to fixed bearing components in these simulator studies due to redistribution of knee motion to two articulating interfaces with more linear motions at each interface. This was observed in two rotating platform designs with different UHMWPE bearing materials. In knee simulator studies, wear of TKR bearings was dependent on kinematics at the articulating surfaces and the prosthesis design, as well as the type of material.  相似文献   

6.
There are many methods used to represent joint kinematics (e.g., roll, pitch, and yaw angles; instantaneous center of rotation; kinematic center; helical axis). Often in biomechanics internal landmarks are inferred from external landmarks. This study represents mandibular kinematics using a non-orthogonal floating axis joint coordinate system based on 3-D geometric models with parameters that are "clinician friendly" and mathematically rigorous. Kinematics data for two controls were acquired from passive fiducial markers attached to a custom dental clutch. The geometric models were constructed from MRI data. The superior point along the arc of the long axis of the condyle was used to define the coordinate axes. The kinematic data and geometric models were registered through fiducial markers visible during both protocols. The mean absolute maxima across the subjects for sagittal rotation, coronal rotation, axial rotation, medial-lateral translation, anterior-posterior translation, and inferior-superior translation were 34.10 degrees, 1.82 degrees, 1.14 degrees, 2.31, 21.07, and 6.95 mm, respectively. All the parameters, except for one subject's axial rotation, were reproducible across two motion recording sessions. There was a linear correlation between sagittal rotation and translation, the dominant motion plane, with approximately 1.5 degrees of rotation per millimeter of translation. The novel approach of combining the floating axis system with geometric models succinctly described mandibular kinematics with reproducible and clinician friendly parameters.  相似文献   

7.
The four-bar linkage mechanism used by many designers for the knee joint of an above-knee prosthesis can provide knee rotation suitable for walking only. In Afro-Asian countries people are habituated to the squatting posture in their daily activities. A six-bar linkage knee-ankle mechanism above-knee prosthesis with a pneumatic swing phase control is developed and its analysis shows its suitability for producing a motion closely resembling that of a normal subject during walking and squatting.  相似文献   

8.
Twenty-three knees were sectioned, digitized, and standardized to determine the 'average' three-dimensional bony geometry and ligamentous attachments. Data on normal knee motion were obtained from a cadaveric study. An algorithm was written to simulate three-dimensional patella motion. Verification of the knee model was achieved by determining femoro-tibial and patello-femoral contact locations, as well as ligament length patterns, and comparing the results with published data. The criterion for maximum predicted knee motion with a prosthesis in place was the length of the posterior cruciate ligament. Three total knee replacement surfaces were mathematically generated: flat, laxity and conforming. A greater flexion angle was obtained with a flat tibial surface than for the laxity or conforming. Posterior tibial component displacement increased the range of motion, but only slightly. For all tibial surfaces, increased range of motion was achieved with a 10 degrees posterior tilt of the tibial tray. Anterior femoral component displacement increased motion due to reduction in posterior cruciate tension during flexion. The results are applicable to the design and surgical technique of total knee replacement.  相似文献   

9.
Fluoroscopic image technique, using either a single image or dual images, has been widely applied to measure in vivo human knee joint kinematics. However, few studies have compared the advantages of using single and dual fluoroscopic images. Furthermore, due to the size limitation of the image intensifiers, it is possible that only a portion of the knee joint could be captured by the fluoroscopy during dynamic knee joint motion. In this paper, we presented a systematic evaluation of an automatic 2D-3D image matching method in reproducing spatial knee joint positions using either single or dual fluoroscopic image techniques. The data indicated that for the femur and tibia, their spatial positions could be determined with an accuracy and precision less than 0.2?mm in translation and less than 0.4° in orientation when dual fluoroscopic images were used. Using single fluoroscopic images, the method could produce satisfactory accuracy in joint positions in the imaging plane (in average up to 0.5?mm in translation and 1.3° in rotation), but large variations along the out-plane direction (in average up to 4.0?mm in translation and 2.2° in rotation). The precision of using single fluoroscopic images to determine the actual knee positions was worse than its accuracy obtained. The data also indicated that when using dual fluoroscopic image technique, if the knee joint outlines in one image were incomplete by 80%, the algorithm could still reproduce the joint positions with high precisions.  相似文献   

10.
The accuracy of estimating the relative pose between knee replacement components, in terms of clinical motion, is important in the study of knee joint kinematics. The objective of this study was to determine the accuracy of the single-plane fluoroscopy method in calculating the relative pose between the femoral component and the tibial component, along knee motion axes, while the components were in motion relative to one another. The kinematics of total knee replacement components were determined in vitro using two simultaneous methods: single-plane fluoroscopic shape matching and an optoelectronic motion tracking system. The largest mean differences in relative pose between the two methods for any testing condition were 2.1°, 0.3°, and 1.1° in extension, abduction, and internal rotation respectively, and 1.3, 0.9, and 1.9 mm in anterior, distal, and lateral translations, respectively. For the optimized position of the components during dynamic trials, the limits of agreement, between which 95% of differences can be expected to fall, were -2.9 to 4.5° in flexion, -0.9 to 1.5° in abduction, -2.4 to 2.1° in external rotation, -2.0 to 3.9 mm in anterior-posterior translation, -2.2 to 0.4mm in distal-proximal translation and -7.2 to 8.6mm in medial-lateral translation. These mean accuracy values and limits of agreement can be used to determine whether the shape-matching approach using single-plane fluoroscopic images is sufficiently accurate for an intended motion tracking application.  相似文献   

11.
Attaching tantalum markers to prostheses for Roentgen stereophotogrammetry (RSA) may be difficult and is sometimes even impossible. In this study, a model-based RSA method that avoids the attachment of markers to prostheses is presented and validated. This model-based RSA method uses a triangulated surface model of the implant. A projected contour of this model is calculated and this calculated model contour is matched onto the detected contour of the actual implant in the RSA radiograph. The difference between the two contours is minimized by variation of the position and orientation of the model. When a minimal difference between the contours is found, an optimal position and orientation of the model has been obtained. The method was validated by means of a phantom experiment. Three prosthesis components were used in this experiment: the femoral and tibial component of an Interax total knee prosthesis (Stryker Howmedica Osteonics Corp., Rutherfort, USA) and the femoral component of a Profix total knee prosthesis (Smith & Nephew, Memphis, USA). For the prosthesis components used in this study, the accuracy of the model-based method is lower than the accuracy of traditional RSA. For the Interax femoral and tibial components, significant dimensional tolerances were found that were probably caused by the casting process and manual polishing of the components surfaces. The largest standard deviation for any translation was 0.19mm and for any rotation it was 0.52 degrees. For the Profix femoral component that had no large dimensional tolerances, the largest standard deviation for any translation was 0.22mm and for any rotation it was 0.22 degrees. From this study we may conclude that the accuracy of the current model-based RSA method is sensitive to dimensional tolerances of the implant. Research is now being conducted to make model-based RSA less sensitive to dimensional tolerances and thereby improving its accuracy.  相似文献   

12.
Accurate in vivo measurement of tibiofemoral forces is important in total knee arthroplasty. These forces determine polyethylene stresses and cold-flow, stress distribution in the implant, and stress transfer to the underlying implant bone interface. Theoretic estimates of tibiofemoral forces have varied widely depending on the mathematical models used. The six degrees of freedom of motion, complex articular surface topography, changing joint-contact position, intra- and extra-articular ligaments, number of muscles crossing the knee joint, and the presence of the patellofemoral joint contribute to the difficulty in developing reliable models of the knee. A prototype instrumented total knee replacement tibial prosthesis was designed, manufactured, and tested. This prosthesis accurately measured all six components of tibial forces (R2>0.997). The prosthesis was also instrumented with an internal microtransmitter for wireless data transmission. Remote powering of the sealed implanted electronics was achieved using magnetic coil induction. This device can be used to validate existing models of the knee that estimate these forces or to develop more accurate models. In conjunction with kinematic data, accurate tibiofemoral force data may be used to design more effective knee-testing rigs and wear simulators. Additional uses are intraoperative measurement of forces to determine soft-tissue balancing and to evaluate the effects of rehabilitation, external bracing, and athletic activities, and activities of daily living.  相似文献   

13.
Fluoroscopic image technique, using either a single image or dual images, has been widely applied to measure in vivo human knee joint kinematics. However, few studies have compared the advantages of using single and dual fluoroscopic images. Furthermore, due to the size limitation of the image intensifiers, it is possible that only a portion of the knee joint could be captured by the fluoroscopy during dynamic knee joint motion. In this paper, we presented a systematic evaluation of an automatic 2D–3D image matching method in reproducing spatial knee joint positions using either single or dual fluoroscopic image techniques. The data indicated that for the femur and tibia, their spatial positions could be determined with an accuracy and precision less than 0.2 mm in translation and less than 0.4° in orientation when dual fluoroscopic images were used. Using single fluoroscopic images, the method could produce satisfactory accuracy in joint positions in the imaging plane (in average up to 0.5 mm in translation and 1.3° in rotation), but large variations along the out-plane direction (in average up to 4.0 mm in translation and 2.2° in rotation). The precision of using single fluoroscopic images to determine the actual knee positions was worse than its accuracy obtained. The data also indicated that when using dual fluoroscopic image technique, if the knee joint outlines in one image were incomplete by 80%, the algorithm could still reproduce the joint positions with high precisions.  相似文献   

14.
While total knee replacement is successful, hemiarthroplasty is necessary for some young, obese and active patients who are especially not suitable for unicompartmental or total knee prostheses. Hemiarthroplasty also provides an opportunity for children with bone tumors. The design ofhemiarthroplasty should be patient-specific to reduce contact stress and friction as well as instability, compared to conventional hemi-knee prosthesis. A novel bipolar hemi-knee prosthesis with two flexion stages was developed according to a healthy male's knee morphological profile. The motion mode of the bipolar hemi-knee prosthesis was observed through roentgenoscopy in vitro experiment. The biomechanical properties in one gait cycle were evaluated though finite element simulation. The bipolar hemi-knee prosthesis was found to produce knee flexion at two stages through X-ray images. The first stage is the motion from upright posture to a specified 60~ flexion, followed by the second stage of motion subsequently to deep flexion. The finite element simulation results also show that the designed hemi-knee prosthesis has the ability to reduce stresses on the joint contact surfaces. Therefore, it is possible for the bipolar hemi-knee prosthesis to provide better biotribological performances because it can reduce stresses and potentially wear on the opposing contacting surface during a gait cycle, orovidin~ a t~romisin~ treatment strate~v in future Joint renair znd renlneement  相似文献   

15.
Total knee arthroplasty (TKA) is a very successful procedure, but pain or difficulties during activities still persist in patients. Patient outcomes in TKA surgery can be affected by implant design, alignment or patient-related anatomical factors. This paper presents a numerical sensitivity analysis of several TKA types: a fixed bearing, posterior stabilized prosthesis, a high flexion fixed bearing guided motion prosthesis, a mobile bearing prosthesis and a hinge prosthesis. Each prosthesis was virtually implanted on the same cadaver leg model and it underwent a loaded squat, in 10s, between 0° and 120°, similar to several previous experimental tests performed on knee kinematics simulators. The aim of this examination was to investigate the sensitivity of the patello-femoral (PF) and tibio-femoral (TF) contact forces to patient-related anatomical factors, and component position in the different implant types. The following parameters were used for the sensitivity study: the proximo-distal patellar position, the patellar component tilting, the tibial component position and orientation, the locations of the medial and lateral collateral ligaments with respect to femur and tibia and the patellar tendon length. The sensitivity analysis showed that PF contact forces are mostly affected by patella height (increases up to 67% for one TKA type in patella-alta configuration), by an anterior tibial component translation (increases up to 30%), and by patellar component tilting (increases up to 29%); TF contact forces are mostly affected by the anterior displacement of the insertion points of the medial collateral ligament with respect to the reference position (increases up to 48%).  相似文献   

16.
Differences between wear-scar features of simulator-tested and retrieved tibial total knee replacement (TKR) liners have been reported. This disagreement may result from differences between in vivo kinematic profiles and those defined by the International Organization for Standardization (ISO). The purpose of this study was to determine the knee kinematics of a TKR subject group during level walking and compare them with the motion profiles defined by the ISO standard for a displacement-controlled knee wear testing simulator. Twenty-nine patients with a posterior cruciate ligament-retaining TKR design were gait tested using the point cluster technique to obtain flexion–extension (FE) rotation, anterior–posterior (AP) translation and internal–external (IE) rotation knee motions during a complete cycle of level walking. Relative ranges of motion and timing of key points within the in vivo motion data were compared against the same ranges and same key points from the input profiles of the displacement-controlled wear testing standard ISO14243-3. The subjects exhibited a FE pattern similar to ISO, with an insignificant difference in range of FE rotation from midstance to terminal stance. However, the subjects had a significantly higher range of knee flexion from terminal stance into swing. The subjects also exhibited a phase delay for the entire gait cycle. For AP translation, the standard profile had statistically significant lower magnitudes than seen in vivo. Opposite pattern of AP motion was also apparent from midstance and swing. Similarly, ISO specified a smaller IE total range of rotation with a motion pattern in complete opposition to that seen in vivo. In conclusion, significant differences were found in both the magnitudes and pattern of in vivo motion compared with ISO.  相似文献   

17.
In this work we tackled the problem of accurate measurement of internal-external (IE) rotations in the prosthetic knee. We presented a magnetic measurement system to be implanted in the knee prostheses in order to measure IE without soft tissue artifacts. The measurement system consisted of a permanent magnet attached under the tibial plate of the prosthesis and a combination of magnetic sensors in the polyethylene insert. Two different sensor configurations were designed, and five different angle estimators for measurement of IE angles were defined and tested based on several static and dynamic measurements toward a stereophotogrammetry motion capture system. Also a noise analysis was done to see which estimators are less sensitive to measurement noise. One-sensor configuration provided lower power budget with dynamic RMS error of 0.49° and a noise range of ±0.53°. Two-sensor configuration doubles the power consumption but provided slightly lower dynamic RMS error (0.37°) and a noise range of ±0.42°, and offers the possibility of having redundancy in case of damaged sensor.  相似文献   

18.
This study investigated the effect of hamstring co-contraction with quadriceps on the kinematics of the human knee joint and the in-situ forces in the anterior cruciate ligament (ACL) during a simulated isometric extension motion of the knee. Cadaveric human knee specimens (n = 10) were tested using the robotic universal force moment sensor (UFS) system and measurements of knee kinematics and in-situ forces in the ACL were based on reference positions on the path of passive flexion/extension motion of the knee. With an isolated 200 N quadriceps load, the knee underwent anterior and lateral tibial translation as well as internal tibial rotation with respect to the femur. Both translation and rotation increased when the knee was flexed from full extension to 30 of flexion; with further flexion, these motion decreased. The addition of 80 N antagonistic hamstrings load significantly reduced both anterior and lateral tibial translation as well as internal tibial rotation at knee flexion angles tested except at full extension. At 30 of flexion, the anterior tibial translation, lateral tibial translation, and internal tibial rotation were significantly reduced by 18, 46, and 30%, respectively (p<0.05). The in-situ forces in the ACL under the quadriceps load were found to increase from 27.8+/-9.3 N at full extension to a maximum of 44.9+/-13.8 N at 15 of flexion and then decrease to 10 N beyond 60 of flexion. The in-situ force at 15 was significantly higher than that at other flexion angles (p<0.05). The addition of the hamstring load of 80 N significantly reduced the in-situ forces in the ACL at 15, 30 and 60 of flexion by 30, 43, and 44%, respectively (p<0.05). These data demonstrate that maximum knee motion may not necessarily correspond to the highest in-situ forces in the ACL. The data also suggest that hamstring co-contraction with quadriceps is effective in reducing excessive forces in the ACL particularly between 15 and 60 of knee flexion.  相似文献   

19.
BACKGROUND: The management of soft tissue balance during surgery is essential for the success of total knee arthroplasty (TKA) but remains difficult, leaving it much to the surgeon's feel. Previous assessments for soft tissue balance have been performed under unphysiological joint conditions, with patellar eversion and without the prosthesis only at extension and 90 deg of flexion. We therefore developed a new tensor for TKA procedures, enabling soft tissue balance assessment throughout the range of motion while reproducing postoperative joint alignment with the patellofemoral (PF) joint reduced and the tibiofemoral joint aligned. Our purpose in the present study was to clarify joint gap kinematics using the tensor with the CT-free computer assisted navigation system. METHOD OF APPROACH: Joint gap kinematics, defined as joint gap change during knee motion, was evaluated during 30 consecutive, primary posterior-stabilized (PS) TKA with the navigation system in 30 osteoarthritic patients. Measurements were performed using a newly developed tensor, which enabled the measurement of the joint gap throughout the range of motion, including the joint conditions relevant after TKA with PF joint reduced and trial femoral component in place. Joint gap was assessed by the tensor at full extension, 5 deg, 10 deg, 15 deg, 30 deg, 45 deg, 60 deg, 90 deg, and 135 deg of flexion with the patella both everted and reduced. The navigation system was used to obtain the accuracy of implantations and to measure an accurate flexion angle of the knee during the intraoperative joint gap measurement. RESULTS: Results showed that the joint gap varied depending on the knee flexion angle. Joint gap showed an accelerated decrease during full knee extension. With the PF joint everted, the joint gap increased throughout knee flexion. In contrast, the joint gap with the PF joint reduced increased with knee flexion but decreased after 60 deg of flexion. CONCLUSIONS: We clarified the characteristics of joint gap kinematics in PS TKA under physiological and reproducible joint conditions. Our findings can provide useful information for prosthetic design and selection and allow evaluation of surgical technique throughout the range of knee motion that may lead to consistent clinical outcomes after TKA.  相似文献   

20.
In the natural knee, the femoral tibial contacts move posteriorly as the knee is flexed, guided primarily by the cruciate ligaments. This kinematic behaviour is important regarding muscle lever arms and in achieving a high flexion range. Most contemporary total knee designs use either posterior cruciate preservation or a cam system to produce posterior displacement with flexion, but there is no specific provision for anterior displacement. In this study, a method for the design of cams is described where the cams would guide the motion in both posterior and anterior directions, without requiring cruciate ligaments. The cams consist of a femoral Guide Surface interacting with a tibial Guide Surface while the main lateral and medial bearing surfaces carry the forces across the knee. It is shown that Guide Surfaces can be designed which provide the required motion, but with some laxity at different flexion ranges. It is then demonstrated that the Guide Surfaces can be applied to a range of possible knee designs including mobile-bearing types, rotating-platform types, and fixed-bearing types. The relative advantages of the different possibilities are discussed.  相似文献   