首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Several techniques were evaluated for the quantitation of the total protein content of an IgG2a monoclonal antibody, KS1/4, and its deacetylvinblastine (DAVLB) conjugate. The UV assay is rapid, but it requires an extensive calibration of the response factor, and impurities may cause a high bias. Amino acid analysis (AAA) is an absolute method that has few interferences, but it requires evaluation of hydrolysis recovery factors. Kjeldahl nitrogen is very sensitive to minor impurities, and it requires a conversion factor to calculate percent protein. The Kjeldahl assay also is less precise (observed RSD of 3-4%) than the UV and AAA assays (observed RSD of 2-3% for both). The bicinchoninic acid assay, a representative of colorimetric assays, inherently requires comparison to a calibrated standard of the same material and tends to be less precise than the other assays. Thus, the UV and AAA assays are the techniques of choice for measurement of the total protein content of KS1/4 and its DAVLB conjugate.  相似文献   

2.
A new methodology for the rapid assessment of affinity ligands synthesized by combinatorial solid-phase chemistry is reported. This screening strategy utilizes the target protein conjugated to FITC, and represents an almost universal technique for the preliminary screening of solid-phase combinatorial libraries. The assessment of a triazine-scaffolded solid-phase combinatorial library of ligands, designed to bind to human IgG, was performed with FITC-human IgG, and the results compared with those obtained by conventional affinity chromatographic screening assays. The effect of different molar conjugation ratios of FITC-IgG (F/P) was evaluated. Independently of the F/P ratio, no false negative results were observed, although lower F/P ratios diminished non-specific interactions and the number of false positives. The nature of the substituents on the triazine scaffold was not related to the number of false positive IgG-binding ligands. The reproducibility of the FITC technique, using FITC-human IgG conjugates with low F/P ratio (F/P=2), was also evaluated. The FITC-based technique proved to be efficient and accurate in the identification of strongly binding ligands (binding >50% of loaded protein, by standard affinity chromatographic assays), and is envisaged as a versatile and cost-effective method to screen other systems, and evaluate several binding/elution conditions at small-scale, prior to scale-up to standard affinity chromatography.  相似文献   

3.
A solid-phase immunoassay has been developed for human immunoglobulin (Ig) E. The specific binding of 125I-labeled protein A (125I-PA) to the Fc region of rabbit IgG anti-IgE served as a quantitative measure of specific anti-IgE antibody bound to the IgE beads under optimal assay conditions. Inhibition of antibody binding by known amounts of standard IgE was reflected in a decreased binding of 125I-PA. The degree of inhibition of 125I-PA binding was related to the amount of fluid-phase IgE present and gave a standard curve which was used to determine the concentration of IgE in test samples. The sensitivity of this method and a double antibody radioimmunoassay (RIA), which was developed using the same IgE preparation and anti-IgE antibody, was approximately the same. These assays gave similar results when used to determine levels of IgE in normal human sera that had been absorbed with protein A—Sepharose to remove components responsible for specific and nonspecific interference in the assays.  相似文献   

4.
Northern elephant seal (NES) serum concentrations of total immunoglobulin (Ig) G, an IgG sub-class, and an IgM-like protein were determined by capture immunoassay using three monoclonal antibodies with specificities for Ig of members of the Phocidae pinniped family. These assays were calibrated for use with NES sera using affinity column purified Ig. Concentrations of these Ig populations were estimated in adult female sera sampled at two time points during the lactation period, as well as sera from their pups collected during the first 5 weeks after birth. In pups, concentrations of the IgM-like protein was found to increase rapidly post-partum. In some individuals, values reached mean concentrations within 10–14 days. In addition, rapid increases in pup total IgG and IgG sub-class concentrations were also observed. Collectively, these findings suggest that the majority of post-partum increases in serum Ig can be accounted for by de-novo synthesis.  相似文献   

5.
Block copolymers are increasingly being applied in areas such as transfection, membrane sealing, site-specific targeting, and bionanoengineering yet there is a relative paucity of assays available for simple, stable and reproducible colorimetric determination of copolymer concentration in solution. We have focused on improving the accuracy and reproducibility of a modified version of the Stewart biphasic colorimetric assay for quantitative determination of Pluronic (poloxamer) and Tetronic (poloxamine) macromolecules. The optimized assay achieved linear response ranges in chloroform for commonly used copolymers such as poloxamine 904 (20-300 microg/ml), poloxamine 908 (10-400 microg/ml), poloxamer 402 (20-400 microg/ml), and poloxamer 407 (10-400 microg/ml). Variation in the type of chlorinated solvent used significantly increased assay sensitivity, presumably through macromolecular reorientation, affording increased access for copolymer-ferrothiocyanate complexation. This was found to be optimally favored by the planar geometry of the solvent cis 1,2-dichloroethylene. For application to biological systems copolymer-protein interactions were for the first time determined and were found to be dependent on the fraction of hydrophobic constituents of the block copolymers and protein type. For instance serum albumin was found to interact with copolymers of low hydrophilic-lipophilic balance values and poly(propylene oxide) contaminants, whereas this interaction was not significant with the relatively hydrophilic IgG. In such systems the colorimetric assay directly determines the fraction of unbound (free) copolymer in the presence of proteins.  相似文献   

6.
We tried to establish an assay system for screening and assessment of immunoregulatory factors using whole cell cultures of mouse splenocytes and found that splenic adhesive cells markedly increased immunogobulin (Ig) production of splenocytes. In the absence of adhesive cells, lipopolysaccharides, pokeweed mitogen, and phytohemagglutinin stimulated the production of IgA, IgG, and IgM in a class-dependent manner. Adhesive cells increased more markedly Ig production of splenocytes stimulated with these mitogens. When mouse splenocytes were cultured with milk proteins in the absence of adhesive cells, lactoferrin, beta-lactoglobulin, alpha-casein, and beta-casein stimulated IgA and IgG production. Adhesive cells increased IgA production of splenocytes stimulated with milk proteins, especially. These results suggest that the assay system is useful for assessment of Ig production-regulating factors.  相似文献   

7.
Ubiquitination is a widely studied regulatory modification involved in protein degradation, DNA damage repair, and the immune response. Ubiquitin is conjugated to a substrate lysine in an enzymatic cascade involving an E1 ubiquitin-activating enzyme, an E2 ubiquitin-conjugating enzyme, and an E3 ubiquitin ligase. Assays for ubiquitin conjugation include electrophoretic mobility shift assays and detection of epitope-tagged or radiolabeled ubiquitin, which are difficult to quantitate accurately and are not amenable to high-throughput screening. We have developed a colorimetric assay that quantifies ubiquitin conjugation by monitoring pyrophosphate released in the first enzymatic step in ubiquitin transfer, the ATP-dependent charging of the E1 enzyme. The assay is rapid, does not rely on radioactive labeling, and requires only a spectrophotometer for detection of pyrophosphate formation. We show that pyrophosphate production by E1 is dependent on ubiquitin transfer and describe how to optimize assay conditions to measure E1, E2, and E3 activity. The kinetics of polyubiquitin chain formation by Ubc13–Mms2 measured by this assay are similar to those determined by gel-based assays, indicating that the data produced by this method are comparable to methods that measure ubiquitin transfer directly. This assay is adaptable to high-throughput screening of ubiquitin and ubiquitin-like conjugating enzymes.  相似文献   

8.
Protein G is an immunoglobulin (IgG)-binding bacterial cell wall protein recently isolated from group G streptococci. We have investigated the avidity of protein G for various monoclonal and polyclonal Ig of the IgG class, and compared it with the binding properties of protein A, the staphylococcal Fc-binding protein. Radiolabeled Ig were mixed with Sepharose-coupled protein G or protein A, and the amounts of radioactivity bound to the matrix-coupled bacterial proteins were determined. The avidity was found to be greater for protein G than for protein A for all examined Ig. Protein G bound all tested monoclonal IgG from mouse IgG1, IgG2a, and IgG3, and rat IgG2a, IgG2b, and IgG2c. In addition, polyclonal IgG from man, cow, rabbit, goat, rat, and mouse bound to protein G, whereas chicken IgG did not. The binding property of protein G was additionally exploited in the Western blot assay, in which iodine-labeled protein G was used successfully for the detection of a rat monoclonal antibody against ovalbumin, and for the detection of rabbit and goat polyclonal whole antisera against human urinary proteins. In these experimental situations, protein G was found to be a powerful reagent for the detection of IgG, and consequently the antigen against which these antibodies are directed.  相似文献   

9.
To develop a fluorescent ruthenium complex for biosensing, we synthesized a novel sulfhydryl-reactive compound, 4-bromophenanthroline bis-2,2'-dipyridine Ruthenium bis (hexafluorophosphate). The synthesized Ru(II) complex was crosslinked with thiol-modified protein G to form a universal reagent for fluorescent immunoassays. The resulting Ru(II)-protein G conjugates were identified by sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE). The emission peak wavelength of the Ru(II)-protein G conjugate was 602 nm at the excitation of 452 nm which is similar to the spectra of the Ru(II) complex, indicating that Ru(II)-protein G conjugates still remain the same fluorescence after conjugation. To test the usefulness of the conjugate for biosensing, immunoglobulin G (IgG) binding assay was conducted. The result showed that Ru(II)-protein G conjugates were capable of binding IgG and the more cross-linkers to modify protein G, the higher conjugation efficiency. To demonstrate the feasibility of Ru(II)-protein G conjugates for fluorescent immunoassays, the detection of recombinant histidine-tagged protein using the conjugates and anti-histidine antibody was developed. The results showed that the histidine-tagged protein was successfully detected with dose-response, indicating that Ru(II)-protein G conjugate is a useful universal fluorescent reagent for quantitative immunoassays.  相似文献   

10.
A concept involving the use of antibody conjugated with reporter molecules for direct sensing of subtle changes in the local electrostatic environment of an antigen-antibody complex due to the antigen binding is presented. The proposed direct sensing mechanism is studied using the protein A-immunoglobulin G (IgG) complex as the model system. The change in the local electrostatic potential and pH around the protein A-IgG complex is observed by measuring the fluorescence intensity of fluorescein molecules conjugated with protein A before and after the introduction of IgG. Factors affecting the efficiency of our direct sensing mechanism including the conjugation ratio of fluorescein per protein A molecule, Solution conditions, and the amount of protein A-fluorescein conjugate used in the experiment are investigated. The IgG(2A) concentrations in the cell supernatants are analyzed by using our direct sensing method and then compared with the results obtained from enzyme-linked immunosorbent assay (ELISA). The comparisons between our homogeneous assay and heterogeneous ELISA in the analysis time, analysis procedures, cost, and sensitivity are reported and discussed. (c) 1992 John Wiley & Sons, Inc.  相似文献   

11.
Using a plaque assay with immunoglobulin (Ig)-coated SRBC, we and others have previously reported that the majority of polyclonally activated mouse lymphocytes secreted antibodies that appeared to be IgM anti-IgG autoantibodies. Careful reexamination of this assay, with application of several highly purified mouse serum and myeloma IgG and IgM preparations, revealed that IgM, which was a minor contaminant of Ig preparations, rather than IgG, was responsible for the formation of these plaques. High numbers of plaques could also be detected in assays with polyclonally activated human lymphocytes, Ig-coated SRBC, and anti-Ig developing sera. Of all IgG-, IgM- or IgA-secreting cells, 40 to 100% were detected with SRBC coated with gamma-globulin or Ig of the same isotype as the isotype to which the developing serum was specific; in general, low proportions of all PFC were detected with SRBC coated with Ig of a different isotype. Studies on the sequence of events leading to the formation of plaques with Ig-sensitized SRBC (both in humans and mice) revealed that antibodies detected in these assays were not able to bind to the Ig-coated SRBC (without the presence of developing serum), and therefore were not anti-Ig autoantibodies. It is our conclusion that the plaque assays with Ig-coated SRBC represent another type of a reverse hemolytic PFC assay that detects cells secreting antibodies regardless of their specificity, and these plaques are formed due to the cross-linking by the anti-Ig developing serum of the Ig coated on SRBC and the Ig secreted by lymphocytes. Our results confirmed preferential induction of anti-DNA antibody secreting cells in mice by showing that these antibodies indeed bind to DNA coated on SRBC. In cultures of polyclonally activated human lymphocytes, anti-DNA and anti-erythrocyte autoantibody-secreting cells were over 10 to 100 times less frequent than in mice. These results, therefore, disprove the concept of preferential induction of anti-Ig autoantibodies in the polyclonal activation of mouse and human lymphocytes, and show that anti-DNA and anti-erythrocyte autoantibodies are easily induced in the polyclonal activation of mouse, but not human, lymphocytes.  相似文献   

12.
Therapeutic vaccination of B cell lymphoma patients with tumor-specific Ig (idiotype, or Id) chemically coupled to the immunogenic foreign carrier protein keyhole limpet hemocyanin (KLH) using glutaraldehyde has shown promising results in early clinical trials, and phase III trials are underway. However, glutaraldehyde Id-KLH vaccines fail to elicit anti-Id immune and clinical responses in many patients, possibly because glutaraldehyde reacts with lysine, cysteine, tyrosine, and histidine residues, damaging critical immunogenic epitopes. A sulfhydryl-based tumor Ag-carrier protein conjugation system using maleimide chemistry was used to enhance the efficacy of Id-KLH vaccines. Maleimide Id-KLH conjugates eradicated A20 lymphoma from most tumor-bearing mice, whereas glutaraldehyde Id-KLH had little efficacy. Maleimide Id-KLH elicited tumor-specific IgG Abs and T cells, with CD8(+) T cells being the major effectors of antilymphoma immunity. Maleimide Id-KLH vaccines also demonstrated superior efficacy in 38C13 and BCL-1 lymphoma models, where Abs were shown to be critical for protection. Importantly, standard glutaraldehyde Id-KLH conjugation procedures could result in "overconjugation" of the tumor Ag, leading to decreased efficacy, whereas the heterobifunctional maleimide-based conjugation yielded potent vaccine product regardless of conjugation duration. Under lysosomal processing conditions, the Id-carrier protein linkage was cleavable only after maleimide conjugation. Maleimide KLH conjugation was easily performed with human Igs analogous to those used in Id-KLH clinical trials. These data support the evaluation of sulfhydryl-based Id-KLH vaccines in lymphoma clinical trials and possibly the use of tumor Ag-carrier protein vaccines for other cancers.  相似文献   

13.
14.
Human IgG binding factors (IgG BF) were prepared by immunopurification on IgG immunosorbents from cell-free supernatants of unstimulated peripheral blood mononuclear cells (PB MNC). The suppressive effects of IgG BF was studied using PB MNC stimulated by pokeweed mitogen or by nocardia delipidated cell mitogen. At the end of the culture three parameters of B cell activation were measured: (1) the numbers of IgM-, IgG-, or IgA-containing cells (CC) using direct immunofluorescence, (2) the numbers of IgM, IgG, or IgA plaque-forming cells (PFC) using a Protein A hemolytic plaque assay, and (3) the concentrations of IgM, IgG, or IgA in culture supernatants using an enzyme-linked immunosorbent assay. Addition of IgG BF at the third day of culture resulted in a selective decrease of IgG CC, while IgM CC and IgA CC were increased or unchanged. Conversely, IgG BF induced a nonselective diminution of the number of PFC and of the amount of secreted Ig of the three major Ig classes. Therefore the results demonstrate two distinct effects of IgG BF: (1) an isotype-specific suppression of cells producing IgG, demonstrated by the parallel decrease of IgG CC and IgG PFC, and (2) a blocking of the late stages of B cell maturation evidenced by the discrepancy between normal or elevated Ig CC and decreased Ig PFC of the IgM and IgA classes.  相似文献   

15.
The toxic subunit of a plant ricin has been conjugate by a disulfide bond to a polyclonal rabbit antibody specific for the L-chain of human IgG. Both the antibody and ricin A-chain retained their original biological activity after conjugation. This conjugate proved to be a potent cytotoxin for surface Ig positive Burkitt lymphoma EB-3 cells, growing in vitro and produced 50% inhibition of protein synthesis at level of 1.4 x 10(-9) M. When tested for cytotoxic action on target cells, the composite conjugate molecule was at least 100 times more effective than antibodies alone, ricin A-chain alone or a conjugate ricin A-chain--normal rabbit IgG.  相似文献   

16.
In this paper, an aqueous solution diffusion-localized platform (ASDLP) for multianalyte immunogold staining assays has been developed for the first time by assembling nitrocellulose (NC) strips onto a superhydrophobic polycarbonate (PC) coating with a water contact angle (CA) up to 160°. In the concept-of-proof experiments, the ASDLP was used for colorimetric detection of a human IgG model antigen based on the gold-enhanced gold nanoparticle (AuNP) label amplification. The relative concentration of the analyte captured on NC was further quantified by measuring the intensity of staining result with the use of image analysis software. The comparison study demonstrates that the white superhydrophobic PC-based ASDLP can offer preferable advantages over the commonly adopted bulky piece of NC for immunogold staining assays, in terms of the localized antibody immobilization and reagent addition, the minimization of "coffee effect", uniformity of staining results, quantitative analysis and use efficiency of NC. Moreover, the high selectivity of a multiple antibodies-immobilized NC strip array for multiple antigens in a single sample has been further demonstrated in the multianalyte immunogold staining assay experiments.  相似文献   

17.
We report the assessment and validation of an NS1 epitope-blocking enzyme-linked immunosorbent assay (ELISA) for detection of antibodies to West Nile virus (WNV) in macaques. Sera from naturally infected Macaca nemestrina were tested by ELISA and plaque reduction neutralization test (PRNT). Results were correlated with hemagglutination inhibition (HAI) data. Our results demonstrate that the blocking ELISA rapidly and specifically detects WNV infection in M. nemestrina. In addition, the diagnostic value of 7 commercially available immunoassays (PanBio immunoglobulin [Ig] M ELISA, PanBio IgG ELISA, PanBio immunofluorescence assay (IFA), InBios IgG ELISA, InBios IgM ELISA, Focus Diagnostics IgG ELISA, and Focus Diagnostics IgM ELISA) in M. nemestrina was evaluated and compared with that of the epitope-blocking ELISA. The PanBio IgG ELISA was found to effectively diagnose WNV exposure in M. nemestrina. Further, PanBio IFA slides are fast and reliable screening tools for diagnosing flaviviral exposure in M. nemestrina.  相似文献   

18.
This paper describes a critical comparative evaluation of 5 miniaturised colorimetric assays applicable to cytotoxicity testing of anti-tumour drugs (and other toxins)in vitro. Each assay shows a different linear range for optical density versus cell number, a different sensitivity to change in cell number and a different minimum detectable cell number; the values of these parameters vary with experimental conditions and with cell line used. All the methods gave good correlation with viable cell number (determined by colony forming efficiency) in toxicity assays after 3 or 4 days of treatment, but they underestimated cell death after 2 days. Toxicity levels for individual chemicals (in a standard 6-day assay) are similar for the different assays, irrespective of the mechanism of action of the chemical being tested. Two of the more recently developed assays (APNaOH and SRB) were found to be very sensitive under the conditions examined.  相似文献   

19.
Knowledge of what constitute normal serum immunoglobulin (Ig) concentrations are important for the diagnosis of immunologic disorders. Data on normal Ig evaluated by nephelometry are limited in healthy Asian children, none being available for Thai children. One hundred and forty-eight healthy Thai children aged 2-15 years were tested for serum immunoglobulins G, A, M, G1, G2, G3, and G4 (Ig G, A, M, G1, G2, G3, and G4) by nephelometry. Sixty-three percent were girls of median interquartile range age 6.9 (4.8-9.7) years. The geometric means for each Ig were summarized and categorized by age. Statistical analyses were used to compare Igs between sexes and age groups, and to compare IgG in this study with data from other published studies. The average ratios of IgG subclasses/IgG for Ig G1:2:3:4 were 66:22:5:7%. IgG, IgA, IgG2, and IgG3 concentrations showed a gradual increase with increasing age. There were no significant sex differences for any immunoglobulin isotype (P= 0.971). Our mean IgG concentration was lower than that measured by the radial diffusion method in healthy Thai children (P < 0.05). In all age groups, the mean IgG concentration in our study was significantly higher than that reported in Turkish and USA children, evaluated by the nephelometric and radial diffusion techniques, respectively (both P < 0.001). This study provides information about normal Ig concentrations measured by nephelometry in healthy Asian children and illustrates the importance of ascertaining normal Ig values for age- and ethnic-matched controls using the same assay to diagnose immunologic disorders correctly.  相似文献   

20.
Passive antibody prophylaxis against human immunodeficiency virus type 1 (HIV-1) has been accomplished in primates, suggesting that this strategy may prove useful in humans. While antibody specificity is crucial for neutralization, other antibody characteristics, such as subclass, have not been explored. Our objective was to compare the efficiencies of immunoglobulin G (IgG) subclasses from polyclonal human HIV immune globulin (HIVIG) in the neutralization of HIV-1 strains differing in coreceptor tropism. IgG1, IgG2, and IgG3 were enriched from HIVIG by using protein A-Sepharose. All three subclasses bound major HIV-1 proteins, as shown by Western blot assay and enzyme-linked immunosorbent assay. In HIV-1 fusion assays using X4, R5, or X4R5 envelope-expressing effector cells, IgG3 more efficiently blocked fusion. In neutralization assays with cell-free viruses using X4 (LAI, IIIB), R5 (BaL), and X4R5 (DH123), a similar hierarchy of neutralization was found: IgG3 > IgG1 > IgG2. IgG3 has a longer, more flexible hinge region than the other subclasses. To test whether this is important, IgG1 and IgG3 were digested with pepsin to generate F(ab')(2) fragments or with papain to generate Fab fragments. IgG3 F(ab')(2) fragments were still more efficient in neutralization than F(ab')(2) of IgG1. However, Fab fragments of IgG3 and IgG1 demonstrated equivalent neutralization capacities and the IgG3 advantage was lost. These results suggest that the IgG3 hinge region confers enhanced HIV-neutralizing ability. Enrichment and stabilization of IgG3 may therefore lead to improved HIVIG preparations. The results of this study have implications for the improvement of passive immunization with polyclonal or monoclonal antibodies and suggest that HIV-1 vaccines which induce high-titer IgG3 responses could be advantageous.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏