首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
2.
3.
4.
Aim: To develop and to validate a method for the quantification of Lawsonia intracellularis in porcine faeces by real‐time PCR. Methods and Results: A real‐time PCR including a calibrator based on plasmid DNA for quantification by means of ΔΔCt method was evaluated. The parameters specificity, detection limit, quantification limit, linearity, range, repeatability, precision and recovery were validated. The detection limit of the agent was 1 copy per reaction, and quantification was reliable between 101 and 107 copies per μl reaction volume. The linearity calculated by logistic regression revealed a slope of ?3·329 reflecting an efficiency of 99·7% for the assay. Moreover, it was shown that storage of samples and repetition of tests including DNA isolation by same or other investigators did not influence the outcome. Conclusion: The quantification method described herein revealed consistent results for the quantitation of L. intracellularis in porcine faeces samples. Significance and Impact of the Study: In contrast to common PCR in combination with gel electrophoresis, this validated quantification method based on real‐time PCR enhances a reliable quantification and is even more sensitive.  相似文献   

5.
6.
Genetic modification of human mesenchymal stem cells (MSC) is a powerful tool to improve the therapeutic utility of these cells and to increase the knowledge on their regulation mechanisms. In this context, strong efforts have been made recently to develop efficient nonviral gene delivery systems. Although several studies addressed this question most of them use the end product of a reporter gene instead of the DNA uptake quantification to test the transfection efficiency. In this study, we established a method based on quantitative real‐time PCR (RT‐PCR) to determine the intracellular plasmid DNA copy number in human MSC after lipofection. The procedure requires neither specific cell lysis nor DNA purification. The influence of cell number on the RT‐PCR sensitivity was evaluated. The method showed good reproducibility, high sensitivity, and a wide linear range of 75–2.5 × 106 plasmid DNA copies per cell. RT‐PCR results were then compared with the percentage of transfected cells assessed by flow cytometry analysis, which showed that flow cytometry‐based results are not always proportional to plasmid cellular uptake determined by RT‐PCR. This work contributed for the establishment of a rapid quantitative assay to determine intracellular plasmid DNA in stem cells, which will be extremely beneficial for the optimization of gene delivery strategies. © 2010 American Institute of Chemical Engineers Biotechnol. Prog., 2010  相似文献   

7.
8.
9.
10.
11.
12.
13.
We present a pseudo‐real‐time retinal layer segmentation for high‐resolution Sensorless Adaptive Optics‐Optical Coherence Tomography (SAO‐OCT). Our pseudo‐real‐time segmentation method is based on Dijkstra's algorithm that uses the intensity of pixels and the vertical gradient of the image to find the minimum cost in a geometric graph formulation within a limited search region. It segments six retinal layer boundaries in an iterative process according to their order of prominence. The segmentation time is strongly correlated to the number of retinal layers to be segmented. Our program permits en face images to be extracted during data acquisition to guide the depth specific focus control and depth dependent aberration correction for high‐resolution SAO‐OCT systems. The average processing times for our entire pipeline for segmenting six layers in a retinal B‐scan of 496 × 400 and 240 × 400 pixels are around 25.60 and 13.76 ms, respectively. When reducing the number of layers segmented to only two layers, the time required for a 240 × 400 pixel image is 8.26 ms.  相似文献   

14.
Aim: The objective of this study is to develop a serovar‐specific loop‐mediated isothermal amplification (LAMP) method for sensitive, rapid, and inexpensive detection of Salmonella serovar Enteritidis under field conditions. Methods: A set of six specific primers was designed with Salmonella Enteritidis DNA as the target. LAMP conditions were optimized by incubating the target DNA with the Bst DNA polymerase large fragment in a simple water bath. The sensitivity and specificity of LAMP was then compared with those of fluorescent quantitative real‐time polymerase chain reaction (FQ‐PCR). Results: The results were as follows. (1) Serovar‐specific Salmonella Enteritidis DNA was amplified at 65°C in as early as 20 min in a water bath. (2) A colour change visible to the naked eye indicated a positive amplification reaction. (3) The detection limit of the LAMP assay was 4 copies μl?1; thus, the sensitivity and specificity of this assay is similar to those of the FQ‐PCR. Conclusions: LAMP is a high‐throughput detection technique with high sensitivity, specificity, and simplicity; these factors make it suitable for specifically detecting Salmonella Enteritidis under field conditions and in laboratory settings. Thus, LAMP eliminates the need for complicated equipment and technical training in the detection of this specific serovar. Significance and impact of the study: This is the first study involving the use of LAMP to detect Salmonella serovar‐specific DNA sequences. It is also the first to report an ideal method of distinguishing between Salmonella Enteritidis and other Salmonella under field conditions.  相似文献   

15.
Phytophthora nicotianae is a phytopathogenic oomycete with a wide host range and worldwide distribution. Rapid detection and diagnosis at the early stages of disease development are important for the effective control of P. nicotianae. In this study, we designed a simple and rapid loop‐mediated isothermal amplification (LAMP)‐based detection method for P. nicotianae. We tested three DNA extraction methods and selected the Kaneka Easy DNA Extraction Kit version 2, which is rapid and robust for LAMP‐based detection. The designed primers were tested using mycelial DNA from 35 species (81 isolates) of Phytophthora, 12 species (12 isolates) of Pythium, one isolate of Phytopythium and one isolate each from seven other soil‐borne pathogens. All of the 42 P. nicotianae isolates were detected by these primers, and no other isolates gave positive results. Three isolates were tested for the sensitivity of the reaction, and the lowest amounts of template DNA that could be detected were 10 fg for two isolates and 1 fg for the third. The target was detected within 25 min in all tested samples, including DNA extracted from both inoculated and naturally infected plants. In contrast, PCR assays with P. nicotianae‐specific primers failed or showed weakened detection in several samples. Thus, we found that the rapid DNA extraction and LAMP assay methods developed in this study can be used to detect P. nicotianae with high sensitivity, specificity and stability.  相似文献   

16.
17.
18.
19.
Culicoides (Diptera: Ceratopogonidae) midges are the biological vectors of a number of arboviruses of veterinary importance. However, knowledge relating to the basic biology of some species, including their host‐feeding preferences, is limited. Identification of host‐feeding preferences in haematophagous insects can help to elucidate the transmission dynamics of the arboviruses they may transmit. In this study, a series of semi‐quantitative real‐time polymerase chain reaction (qPCR) assays to identify the vertebrate host sources of bloodmeals of Culicoides midges was developed. Two pan‐reactive species group and seven species‐specific qPCR assays were developed and evaluated. The assays are quick to perform and less expensive than nucleic acid sequencing of bloodmeals. Using these assays, it was possible to rapidly test nearly 700 blood‐fed midges of various species from several geographic locations in Australia.  相似文献   

20.
Quantitative PCR is becoming widespread for diagnosing and monitoring post‐transplantation diseases associated with EBV and CMV. These assays need to be standardized to manage patients in different facilities. Five independent laboratories in Japan compared home‐brew assays and a prototype assay system to establish a standard quantitative procedure for measuring EBV and CMV. Reference standards and a total of 816 (642 EBV and 174 CMV) whole blood samples from post‐transplantation recipients were used for this multicenter evaluation. The prototype reference standard for EBV was compared to a panel of samples, with a theoretical expected value made using EBV‐positive cells containing two virus genome copies per cell. The mean ratio of the reference standard at each site to the standard of the prototype assay was ≤4.15 for EBV among three different sites and ≤3.0 for CMV between two laboratories. The mean of the theoretical expected number of the EBV genome: prototype reference was close to 1.0. The correlation coefficients between the viral copy numbers determined using the prototype assay and those using each home‐brew assay were high (EBV, 0.73–0.83, median = 0.78; CMV, 0.54–0.60, median = 0.57). The dynamics of the EBV and CMV loads in transplant recipients were similar between the assay types. There was an inter‐laboratory difference among the quantification results, indicating that a unified protocol and kit are favorable for standardizing the quantification of EBV and CMV. Such standardization will help to standardize the diagnosis and monitoring of diseases associated with EBV and CMV.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号