首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
2.
3.
The purpose of the present investigation was to examine the effects of 28 days of polyethylene glycosylated creatine (PEG-creatine) supplementation on 1-repetition maximum bench press (1RMBP) and leg extension (1RMLE), mean power (MP), and peak power (PP) from the Wingate Anaerobic test and body weight (BW). This study used a randomized, double-blind, placebo-controlled, parallel design. Twenty-two untrained men (mean age ± SD = 22.1 ± 2.1 years) were randomly assigned to either a Creatine (n = 10) or Placebo (n = 12) group. The Creatine group ingested PEG-creatine (5 g·d), whereas the Placebo group ingested maltodextrin powder (5 g·d). All subjects performed bench press and bilateral leg extension exercises to determine their 1RM values, and 2 consecutive Wingate Anaerobic Tests (separated by 7 minutes) on a cycle ergometer to determine MP and PP before supplementation (day 0) and after 7 (day 7) and 28 (day 28) days of supplementation. The results indicated that there was a significant (p < 0.05) increase in 1RMBP between days 0 and 28 for the Creatine group but not for the Placebo group. There were no significant changes, however, in 1RMLE, MP, PP, or BW for the Creatine or Placebo group. These findings indicated that 28 days of PEG-creatine supplementation without resistance training increased upper body strength but not lower body strength or muscular power. These findings supported the use of the PEG-creatine supplement for increasing 1RMBP strength in untrained individuals.  相似文献   

4.
Despite its apparent relevance, there is no evidence supporting the importance of anaerobic metabolism in Olympic crosscountry mountain biking (XCO). The purpose of this study was to examine the correlation between XCO race time and performance indicators of anaerobic power. Ten XCO riders (age: 28 ± 5 years; weight: 68.7 ± 7.7 kg; height: 177.9 ± 7.4 cm; estimated body fat: 5.7 ± 2.8%; estimated ·VO?max: 68.4 ± 5.7 ml·kg?1·min?1) participating in the Lagos Mountain Bike Championship (Brazil) completed 2 separate testing sessions before the race. In the first session, after anthropometric assessments were performed, the cyclists completed a single 30-second Wingate (WIN) test and an intermittent tests consisting of 5 × 30-second WIN tests (50% of the single WIN load) with 30 seconds of recovery between trials. In the second session, the riders performed a maximal incremental test. A significant correlation was found between race time and maximal power on the 5× WIN test (r = -0.79, IC(95%) -0.94 to -0.32, p = 0.006) and the mean average power on the 5× WIN test normalized by body mass (r = -0.63, IC(95%) -0.90 to -0.01, p = 0.048). The finding of the study supports the use of anaerobic tests for assessing mountain bikers participating in XCO competitions and suggests that anaerobic power is an important determinant of performance.  相似文献   

5.
The purpose of this study was to compare the Wingate cycling and Bosco repeated jumps anaerobic tests. Eleven men (21.36 +/- 1.6 years; 179.1 +/- 9.3 cm; 78.7 +/- 11.0 kg) and 9 women (21.89 +/- 3.66 years; 171.8 +/- 10.0 cm; 75.9 +/- 21.4 kg), all university athletes, volunteered to participate. Subjects performed each test in random order. The tests consisted of a 30-second Wingate test and a 60-second Bosco test. The Wingate test was conducted using a Monark cycle ergometer and the Bosco test was conducted on a force platform. Following the performance of each test, peak lactate concentrations were determined. Average and peak power values were statistically greater in men and on the Bosco test. Peak lactate values were statistically greater in men but did not differ based on test. Correlations between peak lactate concentrations between tests and lactate values with peak or average power were not statistically significant. The relationship between peak power between tests was statistically significant among men, but not women. The results of the study indicated that the Bosco and Wingate tests, which both measure anaerobic characteristics, appear to measure different aspects of anaerobic power and capacity. The Bosco test also may be inappropriate for athletes who are not well trained in jumping.  相似文献   

6.
The purpose of this study was to examine the effects of 7 days of supplementation with 20 g·d?1 of creatine monohydrate (CM) on mean power (MP) and peak power (PP) from the Wingate anaerobic test (WAnT), body weight (BW), 1-repetition maximum (1RM) bilateral leg extension (LE) strength, and 1RM bench press (BP) strength. This study used a randomized, double-blind, placebo-controlled design. Twenty-two men (mean ± SD: age = 22.1 ± 2.0 years; height = 178.0 ± 5.8 cm; body weight [BW] = 77.6 ± 7.6 kg) were randomly assigned to either a supplement (SUPP; n = 10) or placebo (PLAC; n = 12) group. The SUPP group ingested 20 g·d?1 of CM powder for 7 days, whereas the PLAC ingested 20 g·d?1 of maltodextrin powder. Measurements for the PLAC and SUPP groups included BW, PP, and MP from two 30-second WAnTs (separated by 7 minutes), and 1RM strength for LE and BP. Testing was conducted before (PRE) and after (POST) 7 days of ingesting either the supplement or placebo. The results of this study indicated that there was a significant (p ≤ 0.05) increase from PRE to POST testing in MP for the SUPP group (5.4%) but not for the PLAC group (-0.3%). There were no between-group differences, however, for 1RM LE and 1RM BP strength. Furthermore, there were no changes in PP or BW for either group. The findings of this study indicated that loading with 20 g·d?1 of CM for 7 days increased MP (5.4% increase) from the WAnT, but it had no effect on strength (1RM LE and 1RM BP), PP, or BW.  相似文献   

7.
ABSTRACT: Burden, RJ and Glaister, M. The effects of ionized and nonionized compression garments on sprint and endurance cycling. J Strength Cond Res 26(10): 2837-2843, 2012-The aim of this study was to examine the effects of ionized and nonionized compression tights on sprint and endurance cycling performance. Using a randomized, blind, crossover design, 10 well-trained male athletes (age: 34.6 ± 6.8 years, height: 1.80 ± 0.05 m, body mass: 82.2 ± 10.4 kg, V[Combining Dot Above]O2max: 50.86 ± 6.81 ml·kg·min) performed 3 sprint trials (30-second sprint at 150% of the power output required to elicit V[Combining Dot Above]O2max [pV[Combining Dot Above]O2max] + 3 minutes recovery at 40% pV[Combining Dot Above]O2max + 30-second Wingate test + 3 minutes recovery at 40% pV[Combining Dot Above]O2max) and 3 endurance trials (30 minutes at 60% pV[Combining Dot Above]O2max + 5 minutes stationary recovery + 10-km time trial) wearing nonionized compression tights, ionized compression tights, or standard running tights (control). There was no significant effect of garment type on key Wingate measures of peak power (grand mean: 1,164 ± 219 W, p = 0.812), mean power (grand mean: 716 ± 68 W, p = 0.800), or fatigue (grand mean: 66.5 ± 6.9%, p = 0.106). There was an effect of garment type on blood lactate in the sprint and the endurance trials (p < 0.05), although post hoc tests only detected a significant difference between the control and the nonionized conditions in the endurance trial (mean difference: 0.55 mmol·L, 95% likely range: 0.1-1.1 mmol·L). Relative to control, oxygen uptake (p = 0.703), heart rate (p = 0.774), and time trial performance (grand mean: 14.77 ± 0.74 minutes, p = 0.790) were unaffected by either type of compression garment during endurance cycling. Despite widespread use in sport, neither ionized nor nonionized compression tights had any significant effect on sprint or endurance cycling performance.  相似文献   

8.
The traditional warm-up (WU) used by athletes to prepare for a sprint track cycling event involves a general WU followed by a series of brief sprints lasting ≥ 50 min in total. A WU of this duration and intensity could cause significant fatigue and impair subsequent performance. The purpose of this research was to compare a traditional WU with an experimental WU and examine the consequences of traditional and experimental WU on the 30-s Wingate test and electrically elicited twitch contractions. The traditional WU began with 20 min of cycling with a gradual intensity increase from 60% to 95% of maximal heart rate; then four sprints were performed at 8-min intervals. The experimental WU was shorter with less high-intensity exercise: intensity increased from 60% to 70% of maximal heart rate over 15 min; then just one sprint was performed. The Wingate test was conducted with a 1-min lead-in at 80% of optimal cadence followed by a Wingate test at optimal cadence. Peak active twitch torque was significantly lower after the traditional than experimental WU (86.5 ± 3.3% vs. 94.6 ± 2.4%, P < 0.05) when expressed as percentage of pre-WU amplitude. Wingate test performance was significantly better (P < 0.01) after experimental WU (peak power output = 1,390 ± 80 W, work = 29.1 ± 1.2 kJ) than traditional WU (peak power output = 1,303 ± 89 W, work = 27.7 ± 1.2 kJ). The traditional track cyclist's WU results in significant fatigue, which corresponds with impaired peak power output. A shorter and lower-intensity WU permits a better performance.  相似文献   

9.
Critical power (CP) is a theoretical workload representative of an athlete's maximal sustainable pace. Recent research has validated a 3-minute all-out test on a cycle ergometer for determining CP; however, few studies have investigated the sustainability of CP using this test. The purpose of this study was to determine the sustainability of CP established during the 3-minute test and the determinants of sustainability. A group of elite cyclists (N = 21) performed a VO2max test, 3-minute all-out test, and a time to exhaustion (TTE) trial at CP on 3 different days separated by at least 24 hours. Expired gases were collected during all trials and analyzed for VO2 and VCO2. Heart rate was measured by telemetry. Multiple regression was used to determine predictors of sustainability with significance predetermined at p < 0.05. VO2max was measured at 58.9 ± 5.6 ml·kg(-1)·min(-1), ventilation breakpoint at 44.9 ± 5.7 ml·kg(-1)·min(-1) (75% VO2max), and maximum heart rate at 179 ± 10 b·min(-1). Peak power (PP) in the 3-minute all-out test was measured at 738 ± 170 W, and CP was determined at 305 ± 32 W or 79% of VO2max. The VO2 at CP was 55.4 ± 6.9 ml·kg(-1)·min(-1), representing 94% of measured VO2max. The mean TTE at CP was 14.79 ± 8.38 minutes. The difference score of PP - CP significantly predicted TTE (r = 0.65, p < 0.05). No other measured variables contributed to this prediction. Based on sustainability, these data suggest that the 3-minute all-out test may overestimate CP in elite cyclists, which could lead to overtraining if CP determined with this test is used to identify training intensities.  相似文献   

10.
The aim of this study was to evaluate the reliability and validity of a repeated modified agility test (RMAT) to assess anaerobic power and explosiveness. Twenty-seven subjects (age: 20.2 ± 0.9 years, body mass: 66.1 ± 6.0 kg, height: 176 ± 6 cm, and body fat: 11.4 ± 2.6%) participated in this study. After familiarization, subjects completed the RMAT consisting of 10 × 20-m maximal running performances (moving in forward, lateral, and backward) with ~25-second recovery between each run. Ten subjects performed the RMAT twice separated by at least 48 hours to evaluate relative and absolute reliability and usefulness of the test. The criterion validity of the RMAT was determined by examining the relationship between RMAT indices and the Wingate anaerobic test (WAT) performances and both vertical and horizontal jumps. Reliability of the total time (TT) and peak time (PT) of the RMAT was very good, with intraclass correlation coefficient > 0.90 and SEM < 5% and low bias. The usefulness of TT and PT of the RMAT was rated as "good" and "OK," respectively. The TT of the RMAT had significant correlations with the WAT (peak power: r = -0.44; mean power: r = -0.72), vertical jumps (squat jump: r = -0.50; countermovement jump: r = -0.61; drop jump (DJ): r = -0.55; DJ with dominant leg: r = -0.72; DJ with nondominant leg: r = -0.53) and 5 jump test (r = -0.56). These findings suggest that the RMAT is a reliable and valid test for assessing anaerobic power and explosiveness in multisprint sport athletes. Consequently, the RMAT is an easily applied, inexpensive field test and can provide coaches and strength and conditioning professionals with relevant information concerning the choice and the efficacy of training programs.  相似文献   

11.
The purpose of this study was to describe anaerobic peak and mean power characteristics of arms as a function of age, gender and body composition among 50 girls and 50 boys 14 to 19 years of age. Peak (PP) and mean power (MP) output were determined during arm cranking (Wingate anaerobic test). Fat-free weight (FFW) was estimated from skinfolds, and lean arm volume (LAV) was determined by water displacement, corrected for fat volume. PP and MP increased progressively and significantly (P less than 0.05) with age for boys but not for the girls. Boys had significantly larger absolute PP and MP outputs than girls at comparable ages. PP and MP corrected for lean tissue volume were greater in older than younger boys (P less than 0.05), but did not vary significantly with age for girls. Absolute (W) PP and MP were highly correlated with LAV (r = 0.82; r = 0.75) and FFW (r = 0.84; r = 0.78) among boys. The respective r values for girls were 0.60 and 0.49 (LAV); 0.78 and 0.60 (FFW). Absolute peak and mean power, respectively, were more highly correlated with LAV (r = 0.90; r = 0.84) and FFW (r = 0.90; r = 0.85) for the combined data for boys and girls than for similar gender specific comparisons. In conclusion, both anaerobic PP and MP of arms during adolescence are highly correlated with lean tissue volume and fat-free weight, particularly among boys.  相似文献   

12.
The purpose of this study was to develop a 3-minute, all-out test protocol using the Monark cycle ergometer for estimating the critical power (CP) and anaerobic work capacity (AWC) with the resistance based on body weight. Twelve moderately trained adults (mean age ± SD = 23.2 ± 3.5 years) performed an incremental cycle ergometer test to exhaustion. The CP and AWC were estimated from the original work limit (W(lim)) vs. time limit (T(lim)) relationship (CP(PT)) and a 3-minute all-out test (CP(3min)) against a fixed resistance and compared with the CP and AWC estimated from the new 3-minute tests on the Monark cycle ergometer (CP(3.5%) and CP(4.5%)). The resistance values for the CP(3.5%) and CP(4.5%) tests were set at 3.5 and 4.5% of the subject's body weight (kilograms). The results indicated that there were no significant differences (p > 0.05) among mean CP values for CP(PT) (178 ± 47 W), CP(3.5%) (173 ± 40 W), and CP(4.5%) (186 ± 44 W). The mean CP(3min) (193 ± 54 W), however, was significantly greater than CP(PT) and CP(3.5%). There were no significant differences in AWC for the CP(PT) (13,412 ± 6,247 J), CP(3min) (10,895 ± 2,923 J), and CP(4.5%) (9,842 ± 4,394 J). The AWC values for the CP(PT) and CP(3min), however, were significantly greater than CP(3.5%) (8,357 ± 2,946 J). The results of this study indicated that CP and AWC could be estimated from a single 3-minute work bout test on the Monark cycle ergometer with the resistance set at 4.5% of the body weight. A single work bout test with the resistance based on the individual's body weight provides a practical and accessible method to estimate CP and AWC.  相似文献   

13.
This study examined the relationship between 30-second anaerobic power and body composition by performance level in elite Judoists. During a 3-month period, 10 male Korean Judo national team athletes (NT), 26 male university varsity team athletes (VT), and 28 male junior varsity team athletes (JT) were assessed for 30-second anaerobic power and body composition at the Youngin University. Anaerobic power was measured using a 30-second Wingate test. Body composition was assessed via bioelectric impedance analysis in standardized conditions using BioSpace (Korean)-specific prediction formulas. All testing occurred at the beginning of the winter nonseason period but excluded a brief weight-loss period before the competition phase. Anaerobic power measures were significantly greater (p < 0.05) in NT and VT than in JT. Fat-free mass (FFM), muscle mass (MM), and total body water in JT were also greater than in VT and JT (p < 0.05). Muscle mass in VT was significantly lower than in NT (p < 0.05). Fat-free mass in NT was strongly correlated to mean and peak anaerobic power (r = 0.77, p = 0.009; r = 0.87, p < 0.001, respectively). Varsity team athletes also indicated a moderate association between FFM and peak and mean anaerobic power (r = 0.63, p < 0.001; r = 0.48, p = 0.013, respectively). However, relationship between FFM and anaerobic power was not statistically significantly correlated in JT (r = 0.14, p = 0.470; r = 0.23, p = 0.232, separately). In conclusion, our data indicated that anaerobic power is closely correlated with increase in FFM and MM and was different dependent among performance levels. Further research in the field is warranted to elucidate the Judo-specific relationship between FFM and performance.  相似文献   

14.
The purpose of this study was to investigate the presence of a practice effect on the Wingate anaerobic test (WAnT). Twenty-five young adult men (mean age = 20 years) performed 2 trials of the WAnT, which were separated by 7 days. Mean peak power (PP) and mean power (MP) for trials I and II were compared using a 1-way repeated measures analysis of variance to determine if a practice effect existed. Mean PP and MP scores were significantly higher (p < 0.025) on trial II (867.64 and 634.68 W for PP and MP, respectively) than on trial I (764.48 and 604.92 W), indicating that a practice effect occurred. Effect size (Cohen's d) for PP and MP was 0.72 and 0.35, indicating a large effect and small effect, respectively. Therefore, at least 1 full administration should be performed prior to a baseline power output measurement.  相似文献   

15.
Although many studies have been focused on soccer athletes, no comprehensive studies have been conducted on adolescent soccer athletes in the United States. Therefore, the purpose of this study was to quantify the physiological and sport-specific skill characteristics of Olympic Developmental Program (ODP) soccer athletes by age group and game experience. Following written, informed consent, 59 male athletes (age = 14.6 +/- 2.0 years; wt = 60.5 +/- 1.4 kg; ht = 172.4 +/- 1.2 cm) completed a battery of tests to determine aerobic power (VO(2)max), heart rate (HR(max)), ventilation (VE(max)), respiratory exchange ratio (RER), anaerobic threshold (AT), blood pressure (BP(rest/max)), anaerobic power/capacity [peak power (PP), mean power (MP), total work output (TWO), fatigue index (FI)], leg power [vertical squat jump (VJS), countermovement jump (VJC)], body composition [percent body fat (%BF), lean body mass (LBM)], joint range of motion (trunk, back, hip, knee, and ankle), and agility/sport-specific skills (T-test, line drill test, juggling test, Johnson wall volley, and modified-Zelenka circuit). Factor analyses with subsequent multivariate analyses of variance (MANOVAs) indicated significant main effects across age (p = 0.0001) but not by game experience (p = 0.82). Older athletes exhibited greater height, weight, LBM, VE(max), Time(max), PP, TWO, and VSJ values than younger athletes. Although not significant, there were differences with increasing age in the agility tests (T-test, wall volley, and juggling test). In conclusion, improvements in anaerobic power, agility, and sport-specific skill should be addressed at this developmental level of competition.  相似文献   

16.
The aims of this study were to evaluate the effects of caffeine supplementation on sprint cycling performance and to determine if there was a dose-response effect. Using a randomized, double-blind, placebo-controlled design, 17 well-trained men (age: 24 ± 6 years, height: 1.82 ± 0.06 m, and body mass(bm): 82.2 ± 6.9 kg) completed 7 maximal 10-second sprint trials on an electromagnetically braked cycle ergometer. Apart from trial 1 (familiarization), all the trials involved subjects ingesting a gelatine capsule containing either caffeine or placebo (maltodextrin) 1 hour before each sprint. To examine dose-response effects, caffeine doses of 2, 4, 6, 8, and 10 mg·kg bm(-1) were used. There were no significant (p ≥ 0.05) differences in baseline measures of plasma caffeine concentration before each trial (grand mean: 0.14 ± 0.28 μg·ml(-1)). There was, however, a significant supplement × time interaction (p < 0.001), with larger caffeine doses producing higher postsupplementation plasma caffeine levels. In comparison with placebo, caffeine had no significant effect on peak power (p = 0.11), mean power (p = 0.55), or time to peak power (p = 0.17). There was also no significant effect of supplementation on pretrial blood lactate (p = 0.58), but there was a significant time effect (p = 0.001), with blood lactate reducing over the 50 minute postsupplementation rest period from 1.29 ± 0.36 to 1.06 ± 0.33 mmol·L(-1). The results of this study show that caffeine supplementation has no effect on short-duration sprint cycling performance, irrespective of the dosage used.  相似文献   

17.
ABSTRACT: Di Michele, R, Gatta, G, Di Leo, A, Cortesi, M, Andina, F, Tam, E, Da Boit, M, and Merni, F. Estimation of the anaerobic threshold from heart rate variability in an incremental swimming test. J Strength Cond Res 26(11): 3059-3066, 2012-This study aimed to evaluate, in swimming, the agreement between the anaerobic threshold (AT) as determined from the analysis of blood lactate concentration ([La]) and from a new method based on the heart rate (HR) variability (HRV). Fourteen high-level swimmers completed an incremental 7 × 200-m front crawl test, during which the HRV was measured continuously and [La] was collected after each step. To individuate the AT, the trends of the high-frequency HRV spectral power (HFPOW) and of the fraction of HFPOW relative to the respiratory sinus arrhythmia (HFPOW-RSA) were analyzed. In all the subjects, an abrupt increase of both HFPOW and HFPOW-RSA was observed and associated with the AT. The AT parameters determined, respectively, from [La] and HFPOW-RSA were similar (p > 0.05) and highly correlated (HR: 182.0 ± 8.1 vs. 181.1 ± 8.2 b·min, r = 0.93, 95% limits of agreement [LoA]: -6.7 to 4.9 b·min; velocity: 1.47 ± 0.11 vs. 1.47 ± 0.11 m·s, r = 0.98, 95% LoA: -0.05 to 0.05 m·s). Instead, the AT HR and velocity obtained from HFPOW (179.2 ± 8.4 b·min; 1.45 ± 0.11 m·s) were correlated to the corresponding parameters determined from [La] (HR: r = 0.84; velocity: r = 0.94) but underestimated them slightly (95% LoA: -11.9 to 6.3 b·min and -0.11 to 0.05 m·s). These results demonstrate that the AT can be assessed from the HRV in swimming, providing an important testing tool for coaches. Furthermore, using the actual respiratory spectral component, rather than the total HF spectral power, allows us to obtain a more accurate estimate of AT parameters.  相似文献   

18.
We have modified an electromagnetically braked cycle ergometer to provide a sinusoidally varying work load. This was accomplished by applying a low-frequency sinusoidal voltage at the inputs of the electromagnets using a sinusoidal potentiometer, whose shaft was driven by a variable-speed motor, and a voltage-programmable power supply to amplify the signal. The frequency range is currently 0.0017-0.3 Hz. This technique for sinusoidal work loads allow the period, amplitude, and mean position to be easily changed from a console, even during a test if required.  相似文献   

19.
ABSTRACT: Glaister, M, Pattison, JR, Dancy, B, and McInnes, G. Perceptual and physiological responses to recovery from a maximal 30-second sprint. J Strength Cond Res 26(10): 2850-2857, 2012-The aims of this study were to evaluate perceptions of postexercise recovery and to compare patterns of perceived recovery with those of several potential mediating physiological variables. Seventeen well-trained men (age: 22 ± 4 years; height: 1.83 ± 0.05 m; body mass: 78.9 ± 7.6 kg; and body fat: 11.1 ± 2.2%) completed 10 sprint trials on an electromagnetically braked cycle ergometer. Trial 1 evaluated peak power via a 5-second sprint. The remaining trials evaluated (a) the recovery of peak power after a maximal 30-second sprint using rest intervals of 5, 10, 20, 40, 80, and 160 seconds; (b) perceived recovery via visual analog scales; and (c) physiological responses during recovery. The time point in recovery at which individuals perceived they had fully recovered was 163.3 ± 57.5 seconds. Power output at that same time point was 83.6 ± 5.2% of peak power. There were no significant differences between perceived recovery and the recovery processes of V[Combining Dot Above]O2 or minute ventilation (VE). Despite differences in the time courses of perceived recovery and the recovery of power output, individuals were able to closely predict full recovery without the need for external timepieces. Moreover, the time course of perceived recovery is similar to that of V[Combining Dot Above]O2 and VE.  相似文献   

20.
The effects of growth and pubertal development on bio-energetic characteristics were studied in boys aged 6-15 years (n = 144; transverse study). Maximal oxygen consumption (VO2max, direct method), mechanical power at VO2max (PVO2max), maximal anaerobic power (Pmax; force-velocity test), mean power in 30-s sprint (P30s; Wingate test) were evaluated and the ratios between Pmax, P30s and PVO2max were calculated. Sexual maturation was determined using salivary testosterone as an objective indicator. Normalized for body mass VO2max remained constant from 6 to 15 years (49 ml.min-1.kg-1, SD 6), whilst Pmax and P30s increased from 6-8 to 14-15 years, from 6.2 W.kg-1, SD 1.1 to 10.8 W.kg-1, SD 1.4 and from 4.7 W.kg-1, SD 1.0 to 7.6 W.kg-1, SD 1.0, respectively, (P less than 0.001). The ratio Pmax:PVO2max was 1.7 SD 3.0 at 6-8 years and reached 2.8 SD 0.5 at 14-15 years and the ratio P30s:PVO2max changed similarly from 1.3 SD 0.3 to 1.9 SD 0.3. In contrast, the ratio Pmax:P30s remained unchanged (1.4 SD 0.2). Significant relationships (P less than 0.001) were observed between Pmax (W.kg-1), P30s (W.kg-1), blood lactate concentrations after the Wingate test, and age, height, mass and salivary testosterone concentration. This indicates that growth and maturation have together an important role in the development of anaerobic metabolism.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号