首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
T Ono  M Scalf    L M Smith 《Nucleic acids research》1997,25(22):4581-4588
Fragmentation is a major factor limiting mass range and resolution in the analysis of DNA by matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS). Protonation of the nucleobase leads to base loss and backbone cleavage by a mechanism similar to the depurination reactions employed in the chemical degradation method of DNA sequencing. In a previous study [Tang,W., Zhu,L. and Smith,L.M. (1997) Anal. Chem ., 69, 302-312], the stabilizing effect of substituting the 24 hydrogen with an electronegative group such as hydroxyl or fluorine was investigated. These 24 substitutions stabilized the N-glycosidic linkage, blocking base loss and subsequent backbone cleavage. For such chemical modifications to be of practical significance, it would be useful to be able to employ the corresponding 24-modified nucleoside triphosphates in the polymerase-directed synthesis of DNA. This would provide an avenue to the preparation of 24-modified PCR fragments and dideoxy sequencing ladders stabilized for MALDI analysis. In this paper methods are described for the polymerase-directed synthesis of 24-fluoro modified DNA, using commercially available 24-fluoronucleoside triphosphates. The ability of a number of DNA and RNA polymerases to incorporate the 24-fluoro analogs was tested. Four thermostable DNA polymerases [Pfu (exo-), Vent (exo-), Deep Vent (exo-) and UlTma] were found that were able to incorporate 24-fluoronucleotides with reasonable efficiency. In order to perform Sanger sequencing reactions, the enzymes' ability to incorporate dideoxy terminators in conjunction with the 24-fluoronucleotides was evaluated. UlTma DNA polymerase was found to be the best of the enzymes tested for this purpose. MALDI analysis of enzymatically produced 24-fluoro modified DNA using the matrix 2,5-dihydroxy benzoic acid showed no base loss or backbone fragmentation, in contrast to the extensive fragmentation evident with unmodified DNA of the same sequence.  相似文献   

2.
It has become evident that the mystery of life will not be deciphered just by decoding its blueprint, the genetic code. In the life and biomedical sciences, research efforts are now shifting from pure gene analysis to the analysis of all biomolecules involved in the machinery of life. One area of these postgenomic research fields is proteomics. Although proteomics, which basically encompasses the analysis of proteins, is not a new concept, it is far from being a research field that can rely on routine and large-scale analyses. At the time the term proteomics was coined, a gold-rush mentality was created, promising vast and quick riches (i.e., solutions to the immensely complex questions of life and disease). Predictably, the reality has been quite different. The complexity of proteomes and the wide variations in the abundances and chemical properties of their constituents has rendered the use of systematic analytical approaches only partially successful, and biologically meaningful results have been slow to arrive. However, to learn more about how cells and, hence, life works, it is essential to understand the proteins and their complex interactions in their native environment. This is why proteomics will be an important part of the biomedical sciences for the foreseeable future. Therefore, any advances in providing the tools that make protein analysis a more routine and large-scale business, ideally using automated and rapid analytical procedures, are highly sought after. This review will provide some basics, thoughts and ideas on the exploitation of matrix-assisted laser desorption/ ionization in biological mass spectrometry - one of the most commonly used analytical tools in proteomics - for high-throughput analyses.  相似文献   

3.
It has become evident that the mystery of life will not be deciphered just by decoding its blueprint, the genetic code. In the life and biomedical sciences, research efforts are now shifting from pure gene analysis to the analysis of all biomolecules involved in the machinery of life. One area of these postgenomic research fields is proteomics. Although proteomics, which basically encompasses the analysis of proteins, is not a new concept, it is far from being a research field that can rely on routine and large-scale analyses. At the time the term proteomics was coined, a gold-rush mentality was created, promising vast and quick riches (i.e., solutions to the immensely complex questions of life and disease). Predictably, the reality has been quite different. The complexity of proteomes and the wide variations in the abundances and chemical properties of their constituents has rendered the use of systematic analytical approaches only partially successful, and biologically meaningful results have been slow to arrive. However, to learn more about how cells and, hence, life works, it is essential to understand the proteins and their complex interactions in their native environment. This is why proteomics will be an important part of the biomedical sciences for the foreseeable future. Therefore, any advances in providing the tools that make protein analysis a more routine and large-scale business, ideally using automated and rapid analytical procedures, are highly sought after. This review will provide some basics, thoughts and ideas on the exploitation of matrix-assisted laser desorption/ ionization in biological mass spectrometry – one of the most commonly used analytical tools in proteomics – for high-throughput analyses.  相似文献   

4.
  1. Download : Download high-res image (217KB)
  2. Download : Download full-size image
  相似文献   

5.
6.
Foret F  Preisler J 《Proteomics》2002,2(4):360-372
Mass spectrometry is becoming the major analytical tool in biology research. This short review summarizes the state-of-the-art in the interface miniaturization and strategies for analysis of limited sample amounts by matrix assisted laser desorption/ionization mass spectrometry.  相似文献   

7.
Proline-containing peptides of the X-proline type are cleaved by the dipeptidase prolidase. The classical method of prolidase assay relied on the colorimetric estimation of the liberated proline with ninhydrin using acidic media and heat. This method, however, gave inconsistent results due to the nonspecificity of the ninhydrin color reaction. We report here a method for the detection of the liberated proline using matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry. Human sera were incubated with a mixture containing the dipeptide glycyl-proline in Tris-HCl supplemented with manganese at 37 degrees C for 24h. The samples were precipitated with trifluoroacetic acid and centrifuged. An aliquot of the supernatant was mixed with an equal volume of ferulic acid solution. An aliquot from this mixture was spotted on a stainless steel mass spectrometry grid and analyzed using MALDI-TOF mass spectrometry. The activity of the enzyme was determined by the complete disappearance of the glycyl-proline peak with the concomitant appearance of the proline peak and can be expressed in terms of the ratio of the area beneath the proline to the area beneath the glycyl-proline peak. Subjects homozygous for prolidase deficiency had a ratio ranging from 0.006 to 0.04 while obligatory heterozygotes had a ratio ranging from around 1.1 to 2.4. Normal subjects had ratios ranging from 9 to 239. Using this method we have unambiguously identified subjects with homozygous or heterozygous prolidase deficiency. In addition to the advantage of rapid sample preparation time, this method is highly specific, reproducible, and sensitive.  相似文献   

8.
A method is described for the quantitative determination of peptides using matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry. Known limitations imposed by crystal heterogeneity, peptide ionization differences, data handling, and protein quantification with MALDI-TOF mass spectrometry are addressed in this method with a "seed crystal" protocol for analyte-matrix formation, the use of internal protein standards, and a software package called maldi_quant. The seed crystal protocol, a new variation of the fast-evaporation method, minimizes crystal heterogeneity and allows for consistent collection of protein spectra. The software maldi_quant permits rapid and automated analysis of peak intensity data, normalization of peak intensities to internal standards, and peak intensity deconvolution and estimation for vicinal peaks. Using insulin proteins in a background of other unrelated peptides, this method shows an overall coefficient of variance of 4.4%, and a quantitative working range of 0.58-37.5 ng bovine insulin per spot. Coupling of this methodology to powerful analytical procedures such as immunoprecipitation is likely to lead to the rapid and reliable quantification of biologically relevant proteins and their closely related variants.  相似文献   

9.
Photosystem II of higher plants and cyanobacteria is composed of more than 20 polypeptide subunits. The pronounced hydrophobicity of these proteins hinders their purification and subsequent analysis by mass spectrometry. This paper reports the results obtained by application of matrix-assisted laser desorption/ionization mass spectrometry directly to isolated complexes and thylakoid membranes prepared from cyanobacteria and spinach. Changes in protein contents following physiopathological stimuli are also described. Good correlations between expected and measured molecular masses allowed the identification of the main, as well as most of the minor, low molecular weight components of photosystem II. These results open up new perspectives for clarifying the functional role of the various polypeptide components of photosystems and other supramolecular integral membrane complexes.  相似文献   

10.
A robust high-throughput single-nucleotide polymorphism (SNP) genotyping method is reported, which applies allele-specific extension to achieve allelic discrimination and uses matrix-assisted laser desorption/ionization time-of-flight mass spectrometry to measure the natural molecular weight difference of oligonucleotides for determination of the base in a single-nucleotide polymorphic location. Tenfold PCR is performed successfully by carefully designing the primers and adjusting the conditions of PCR. In addition, two ways used for PCR product purification are compared and the matrix used in mass spectrometry for high-throughput oligonucleotide analysis is evaluated. The result here shows that the method is very effective and suitable for high-throughput genotyping of SNPs.  相似文献   

11.
We report a method to detect the presence of dimethylarginines on proteins. Peptides with dimethylarginines were hydrolyzed in acid. The hydrolysates were subjected to matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometric analysis using a mixture of alpha-cyano-4-hydroxycinnamic acid and nitrocellulose as matrix. Both asymmetric omega-N(G),N(G)-dimethylarginine and symmetric omega-N(G),N(G')-dimethylarginine give a clear signal at m/z 203. Recombinant Sbp1p modified by Hmt1p in vivo were isolated by affinity chromatography followed by electrophoresis on a polyacrylamide gel and subjected to acid hydrolysis. MALDI-TOF analysis of the acid hydrolysates confirmed the presence of dimethylarginines. The detection limit of the method is estimated at approximately 1pmol of protein.  相似文献   

12.
Laser desorption/ionization mass spectrometry (MS) is rapidly growing in popularity as an analytical characterization method in several fields. The technique shot to prominence using matrix-assisted desorption/ionization for large biomolecules (>700 Da), such as proteins, peptides and nucleic acids. However, because the matrix, which consists of small organic molecules, is also ionized, the technique is of limited use in the low-molecular-mass range (<700 Da). Recent advances in surface science have facilitated the development of matrix-free laser desorption/ionization MS approaches, which are referred to here as surface-assisted laser desorption/ionization (SALDI) MS. In contrast to traditional matrix-assisted techniques, the materials used for SALDI-MS are not ionized, which expands the usefulness of this technique to small-molecule analyses. This review discusses the current status of SALDI-MS as a standard analytical technique, with an emphasis on potential applications in proteomics.  相似文献   

13.
Laser desorption/ionization mass spectrometry (MS) is rapidly growing in popularity as an analytical characterization method in several fields. The technique shot to prominence using matrix-assisted desorption/ionization for large biomolecules (>700 Da), such as proteins, peptides and nucleic acids. However, because the matrix, which consists of small organic molecules, is also ionized, the technique is of limited use in the low-molecular-mass range (<700 Da). Recent advances in surface science have facilitated the development of matrix-free laser desorption/ionization MS approaches, which are referred to here as surface-assisted laser desorption/ionization (SALDI) MS. In contrast to traditional matrix-assisted techniques, the materials used for SALDI-MS are not ionized, which expands the usefulness of this technique to small-molecule analyses. This review discusses the current status of SALDI-MS as a standard analytical technique, with an emphasis on potential applications in proteomics.  相似文献   

14.
Quantitative matrix-assisted laser desorption/ionization (MALDI) time-of-flight (ToF) mass spectrometry (MS) was applied for the determination of concentrations of low-molecular-weight (< 400Da) substrates and products of enzyme-catalyzed reactions. Isotope-labeled and fluorinated internal standards were used for the quantification. Automated quantitative MALDI-ToF MS analysis of quenched samples allowed the direct and simultaneous observation of time-dependent decrease of substrate concentration and increase of product concentration without any need for prepurification or desalting steps. The results showed good agreement with established but more elaborate analytical methods. MALDI-ToF MS thus is an interesting alternative tool for the determination of enzyme activities. Due to automated and miniaturized measurement it is especially suitable for the screening of biocatalysts.  相似文献   

15.
Harvey DJ 《Proteomics》2005,5(7):1774-1786
This paper reviews methods for the analysis of N-linked glycans by mass spectrometry with emphasis on studies conducted at the Oxford Glycobiology Institute. Topics covered are the release of glycans from sodium dodecyl sulphate-polyacrylamide gel electrophoresis gels, their purification for analysis by mass spectrometry, methods based on matrix-assisted laser desorption/ionization (MALDI) and electrospray ionization for producing fragment ions, and details of their fragmentation. MALDI mass spectrometry provided a rapid method for profiling neutral N-linked glycans as their [M + Na](+) ions which could be fragmented by collision-induced decomposition to give spectra containing both glycosidic and cross-ring fragments. Electrospray ionization mass spectrometry was more versatile in that it was relatively easy to change the type of ion that was formed and, furthermore, unlike MALDI, electrospray did not cause extensive loss of sialic acids from sialylated glycans. Negative ions formed by addition of anions such as chloride and, particularly, nitrate, to the electrospray solvent were stable and enabled singly charged ions to be obtained from larger glycans than was possible in positive ion mode. Fragmentation of negative ions followed specific pathways that defined structural details of the glycans that were difficult to obtain by classical methods such as exoglycosidase digestion.  相似文献   

16.
17.
Cramer R  Corless S 《Proteomics》2005,5(2):360-370
We have combined several key sample preparation steps for the use of a liquid matrix system to provide high analytical sensitivity in automated ultraviolet -- matrix-assisted laser desorption/ionisation -- mass spectrometry (UV-MALDI-MS). This new sample preparation protocol employs a matrix-mixture which is based on the glycerol matrix-mixture described by Sze et al. The low-femtomole sensitivity that is achievable with this new preparation protocol enables proteomic analysis of protein digests comparable to solid-state matrix systems. For automated data acquisition and analysis, the MALDI performance of this liquid matrix surpasses the conventional solid-state MALDI matrices. Besides the inherent general advantages of liquid samples for automated sample preparation and data acquisition the use of the presented liquid matrix significantly reduces the extent of unspecific ion signals in peptide mass fingerprints compared to typically used solid matrices, such as 2,5-dihydroxybenzoic acid (DHB) or alpha-cyano-hydroxycinnamic acid (CHCA). In particular, matrix and low-mass ion signals and ion signals resulting from cation adduct formation are dramatically reduced. Consequently, the confidence level of protein identification by peptide mass mapping of in-solution and in-gel digests is generally higher.  相似文献   

18.
The DNA of all organisms is persistently damaged by endogenous reactive molecules. Most of the single-base endogenous damage is repaired through the base excision repair (BER) pathway that is initiated by members of the DNA glycosylase family. Although the BER pathway is often considered to proceed through a common abasic site intermediate, emerging evidence indicates that there are likely distinct branches reflected by the multitude of chemically different 3′ and 5′ ends generated at the repair site. In this study, we have applied matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI–TOF–MS) to the analysis of model DNA substrates acted on by recombinant glycosylases. We examine the chemical identity of several possible abasic site and nicked intermediates generated by monofunctional and bifunctional glycosylases. Our results suggest that the intermediate from endoIII/Nth might not be a simple β-elimination product as described previously. On the basis of 18O incorporation experiments, we propose a new mechanism for the endoIII/Nth family of glycosylases that may resolve several of the previous controversies. We further demonstrate that the use of an array of lesion-containing oligonucleotides can be used to rapidly examine the substrate preferences of a given glycosylase. Some of the lesions examined here can be acted on by more than one glycosylase, resulting in a spectrum of damaged intermediates for each lesion, suggesting that the sequence and coordination of repair activities that act on these lesions may influence the biological outcome of damage repair.  相似文献   

19.
In view of the fact that memory effects associated with instrument calibration hinder the use of many mass-to-charge (m/z) ratios and tuning standards, identification of robust, comprehensive, inexpensive, and memory-free calibration standards is of particular interest to the mass spectrometry community. Glucose and its isomers are known to have a residue mass of 162.05282 Da; therefore, both linear and branched forms of polyhexose oligosaccharides possess well-defined masses, making them ideal candidates for mass calibration. Using a wide range of maltooligosaccharides (MOSs) derived from commercially available beers, ions with m/z ratios from approximately 500 to 2500 Da or more have been observed using Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR-MS) and time-of-flight mass spectrometry (TOF-MS). The MOS mixtures were further characterized using infrared multiphoton dissociation (IRMPD) and nano-liquid chromatography/mass spectrometry (nano-LC/MS). In addition to providing well-defined series of positive and negative calibrant ions using either electrospray ionization (ESI) or matrix-assisted laser desorption/ionization (MALDI), the MOSs are not encumbered by memory effects and, thus, are well-suited mass calibration and instrument tuning standards for carbohydrate analysis.  相似文献   

20.
Tetrahydrofolylpolyglutamic acid in whole bacteria cells and cell lysates is analyzed by matrix-assisted laser desorption/ionization mass spectrometry. The speed, mass information, and tolerance to impurities of this technique make it ideal for monitoring the glutamation levels of folic acid in biological systems. Folylpolyglutamic acid is observed in a few strains of E. coli and two species of Staphylococcus bacteria. The effects of growth time, growth media, and the addition of methotrexate, a dihydrofolate reductase inhibitor, are also studied.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号