A dual-core and dual D-shaped photonic crystal fiber (PCF)-based surface plasmon resonance (SPR) sensor with silver and aluminum nitride (AlN) films is designed. The distribution characteristics of the electromagnetic fields of core and plasmon modes, as well as the sensing properties, are numerically studied by finite element method (FEM). The structure parameters of the designed sensor are optimized by the optical loss spectrum. The results show the resonance wavelength variation of 489 nm for the refractive index (RI) range of 1.36?~?1.42. In addition, a maximum wavelength sensitivity of 13,400 nm/RIU with the corresponding RI resolution of 7.46?×?10?6 RIU is obtained in the RI range of 1.41?~?1.42. The proposed sensor with the merits of high sensitivity, low cost, and simple structure has a wide application in the fields of RI sensing, such as hazardous gas detection, environmental monitoring, and biochemical analysis.
相似文献We theoretically propose a surface plasmon resonance (SPR)-based fiber optic refractive index (RI) sensor. A surface plasmon exciting metallic grating formed with the alternation of indium tin oxide (ITO) and silver (Ag) stripes is considered on the core of the fiber. A thin film of silicon is used as an overlay. Silicon film not only protects the metallic grating from oxidation but also enhances the field to improve the device sensitivity. The sensor is characterized in terms of sensitivity, detection accuracy (DA), figure of merit (FoM), and quality factor (QF). The maximum sensitivity in the RI range 1.33 to 1.38 refractive index unit (RIU) is reported to be?~25 µm/RIU in infra-red region of investigation.
相似文献Light control capability of photonic crystal fiber (PCF) is a unique feature which can be applied to improve biosensing and plasmonic performance. Here, we reported alphabetic-core microstructure fiber-based plasmonic biosensor. Three different alphabetic R-, M-, and S-shaped cores of PCF-based plasmonic microstructures show controllable light propagation to enhance biosensor sensitivity and resolution. The light-guiding properties and sensing performance are investigated numerically using the finite element method (FEM). The proposed R-shaped core (RSC), M-shaped core (MSC), and S-shaped core (SSC) PCF-based plasmonic sensors show the maximum wavelength and amplitude sensitivities of 12,000, 11,000, 10,000 nm/RIU and 478, 533, and 933 RIU−1, respectively, in the refractive index (RI) range of 1.33 to 1.40. The sensors also exhibit promising wavelength resolution of 8.33 × 10−6, 9.09 × 10−6, and 1.0 × 10−6 RIU, with figure of merit (FOM) of 108, 143, and 217 RIU−1 for RSC, MSC, and SSC PCFs, respectively. The tunable sensing performance is also observed in design structures due to controllable light traveling path and their interaction with analytes. The proposed alphabetic-core PCF SPR sensors would be a promising candidate for the application of light controlling, trapping in microscale environment, and biosensing.
相似文献In this article, a surface plasmon resonance (SPR) biosensor based on D-typed optical fiber coated by Al2O3/Ag/Al2O3 film is investigated numerically. Resonance in near infrared with an optimized architecture is achieved. Refractive index sensitivity of 6558 nm/RIU (refractive index unit) and detection limit of 1.5 × 10−6 RIU, corresponding to 0.4357 nm/μM and detection limit of 23 nM in BSA (bovine serum albumin) concentration sensing, are obtained. The analysis of the performance of the sensor in gaseous sensing indicates that this proposed SPR sensor is much suitable for label-free biosensing in aqueous media.
相似文献This paper deals with the development and analysis of D-Shaped photonic crystal fiber (PCF) biosensors using surface plasmon resonance (SPR). A thin metal layer is deposited on the outer flat surface of the PCF that behaves as the plasmonic material. Analyte is filled in the outermost peripheral region of metal layer. Finite element method (FEM) with perfectly matched layer (PML) is applied to analyze the proposed sensors. Mode analysis is performed on the proposed structures to evaluate various parameters of SPR-based PCF sensors. Three D-shaped PCF structures have been proposed with silver (Ag), gold (Au) and two-half layers of both (Ag-Au) on its flat surface. The first two structures are analyzed to the range of wavelength where the SPR will occur to facilitate understanding of the third structure. It is observed that the structures with one metal have only one sensitive plasmonic peak whereas the structure with two metal layers has two sensitive plasmonic peaks, making it suitable candidate for two-molecule sensing present in a sample analyte. Good sensitivities and resolutions are achieved for both plasmonic peaks.
相似文献In this paper, we demonstrate a high sensitivity refractive index (RI) sensor with D-shaped structure covered with gold and graphene film. Specifically, the effect of structural parameters on the stability of fiber sensor is analyzed. In our research, it have been found that the sensor we proposed is not very sensitive to the change of structure parameters on the premise of ensuring the sensing precision. This advantage means that the requirements for machining errors are reduced. Further probing shows that the proposed sensor shows a maximum wavelength interrogation sensitivity of 4391nm/RIU with the dynamic refractive index range from 1.33 to 1.39 and a maximum amplitude sensitivity of 1139RIU− 1 with the analyte RI = 1.38 in the visible region. The corresponding resolution are 2.28 × 10− 5 and 8.78 × 10− 6 based on the methods of wavelength interrogation and amplitude-(or phase-) based method. These characteristics of compact sensing architectures, simple to fabricate, and high sensitivity open the possibility of using this type of sensor in biological applications.
相似文献In this report, a novel D-shaped long-range surface plasmon resonance (LRSPR) fiber base sensor has been introduced. The demonstration of proposed sensor involves two D-shaped silver-coated models to study the sensitivity responses. The entire study with the constructed models is based on a single-mode fiber. The models are multilayered consisting of metal, dielectric, and analyte as separate layers. Silver (Ag) and magnesium fluoride (MgF2) strips are used as metal and dielectric layers respectively. The constituency of analyte as an interface excellently standardized the models for sensitivity detection. In this report, a large range of analyte refractive indices (RI) which varies from 1.33 to 1.38 is appraised for the proposed models to characterize the sensitivity. The entire context is encompassed by the wavelength region from 450 to 850 nm with an interval of 20 nm. Sensitivities in this report are measured based on the analyte position from the core and metal for both models. For each of the two models, the analyte is placed as the top layer. RIs of the applied metal (Ag) are measured using the Drude-Lorentz formula. The simulated sensitivities for model-1 and model-2 vary from 6.3?×?103 nm/RIU to 8.7?×?103 nm/RIU.
相似文献A speckle-free fast angular interrogation surface plasmon resonance imaging (SPRi) sensor based on a diode-pumped all-solid-state laser and galvanometer is reported in this work. A bidirectional scan using a galvanometer realizes the fast scanning of the incidence angle. The experimental results showed that the time needed for completing an SPR dip measurement was decreased to 0.5 s. And through cascading an immovable diffuser and two diffusers rotating in opposite directions, laser speckle was eliminated. The dynamic detection range and the sensitivity reached 4.6 × 10−2 and 1.52 × 10−6 refractive index unit (RIU), respectively, in a 2D array sensor when the angle scanning range was set as 7.5°. More importantly, the results demonstrated that the angular interrogation SPR imaging sensor scheme had the capability to perform fast and high-throughput detection of biomolecular interactions at 2D sensor arrays.
相似文献In the present work, a novel surface plasmon resonance (SPR) sensor consisting of the nickel (Ni) film with hybrid structure of blue phosphorene (BlueP)/transition metal dichalcogenides (TMDCs) is reported. By optimizing the thickness of Ni layer and BlueP/TMDCs, the maximum sensitivity with 270°/RIU for the Ni-BlueP/WS2 is achieved. Use of BlueP/TMDCs layer facilitates the sensitivity due to its high electron concentration, high mobility, optical, and electronic properties. Compared with the conventional Ni-based SPR sensor, the sensitivity of the proposed one is enhanced up to ~ 60.7%. We hope that the SPR sensor has potential application prospects in chemical detection, medical diagnostic, optical sensing, etc. due to its high sensitivity.
相似文献In this study, we demonstrate the design of a photonic crystal fiber (PCF)-based plasmonic sensor to measure the glucose level of urine. The sensor is designed by placing a small segment of PCF between a lead-in and a lead-out single-mode fiber. We utilize the finite element method to simulate the proposed plasmonic sensor for the measurement of glucose level in urine. To offer external sensing, the cladding layer of the PCF was coated by a thin layer of gold where the gold-coated PCF was immersed in the urine sample. As a result, the urine can easily interact with the plasmonic layer of the sensor. In the outermost laser of the PCF, we considered a perfectly matched layer as a boundary condition. The simulation results confirm excellent wavelength and amplitude sensitivities where the maximum wavelength sensitivity was 2500 nm/RIU and amplitude sensitivity was 152 RIU?1 with a sensing resolution of 4?×?10?6. For optimization of the plasmonic sensor, we varied the physical parameters of the cladding air holes and the thickness of the gold layer during the simulation. We strongly believe that the proposed plasmonic sensor will play a significant role to pave the way for achieving a simple but effective PCF-based glucose sensor.
相似文献A single-polarization photonic crystal fiber (PCF) based on surface plasmon resonance (SPR) is proposed. Finite element method is employed in simulating the PCF with gold-coated. The resonance wavelength can be modulated by changing the thickness of gold layer. At the resonance wavelength 1.55 μm, the loss of y-polarized mode is much larger than the loss of x-polarized mode. When the fiber length is set to 2 mm, the value of extinction ratio reaches to −118.7 dB, the y-polarized mode is suppressed and only x-polarized mode can be guided. The fiber is applicable in the production of single-polarization filter. The PCF has a simple structure and a big error tolerance, it has a good practicability.
相似文献We propose a highly sensitive refractive index sensor based on the surface phonon resonance (SPhR) in the mid-IR spectral range. Surface phonon polaritons (SPhPs) are formed on polar dielectrics such as SiC in mid-IR wavelength range and can be excited with the help of a metallic grating at specific wavelength termed as resonance wavelength. The resonance wavelength of SPhP is significantly affected by the refractive index of the analyte medium placed over the grating. This forms the basis of a refractive index sensor. We have numerically evaluated the performance of such an SPhP-based refractive index sensor by using rigorous coupled wave analysis (RCWA) in terms of sensitivity, detection accuracy, and quality factor. The quality factor and detection accuracy of the sensor formed on SiC substrate are found to be 225.1 RIU–1 (inverse of refractive index unit) and 6.75, respectively. We have also extended the study for other polar dielectric substrates cBN and GaN and observed considerable enhancement in the performance of the sensor for GaN. The values of quality factor and detection accuracy could be increased to 361.2 RIU–1 and 10.84, respectively, by using GaN substrate. The proposed sensor finds applications in refractive index sensing of liquids and biomolecules having refractive index in the range 1.33–1.36.
相似文献We demonstrate that a designed bimetallic chip is capable of improving the performance of a surface plasmon resonance (SPR) sensor based on angular interrogation. Through a numerical simulation and a refractometry experiment, we prove that this bimetallic chip can effectively reduce the noise level by about a factor of 2 compared to the traditional SPR sensors that only use a single gold film. The bimetallic chip presents a lower refractive index resolution of 5.3 × 10−7 refractive index units. In addition, the enhancement of the electric field intensity at the surface of the configuration by a factor of 2 makes it possible to have a high sensitivity in a larger region, which promotes the biosensing applications of the chip. Through a simple and novel method for the detection of cadmium ions (Cd2+) based on the bimetallic configuration, a detection level for Cd2+ (0.01 μM or 1.12 ppb) can be realized, which compares favorably with similar studies.
相似文献