首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Summary Mycoplasmal contamination remains a significant impediment to the culture of eukaryotic cells. For certain cultures, attempts to eliminate the infection are feasible alternatives to the normally recommended disposal of the contaminated culture. Here, three antibiotic regimens for mycoplasmal decontamination were compared in a large panel of naturally infected cultures: a 1-wk treatment with the fluoroquinolone mycoplasma removal agent (MRA), a 2-wk treatment with the fluoroquinolone ciprofloxacin, and three rounds of a sequential 1-wk treatment with BM-Cyclin containing tiamulin and minocyclin. These antibiotic treatments had a high efficiency of permanent cure: MRA 69%, ciprofloxacin 75%, BM-Cyclin 87%. Resistance to mycoplasma eradication was observed in some cell cultures: BM-Cyclin 0%, MRA 20%, ciprofloxacin 20%. Nearly all resistant contaminants that could be identified belonged to the speciesMycoplasma arginini andM. orale. Detrimental effects of the antibiotics were seen in the form of culture death caused by cytotoxicity (in 5 to 13% of the cultures). Alterations of the cellular phenotypic features or selective clonal outgrowth might represent further untoward side effects of exposure to these antibiotics. Overall, antibiotic decontamination of mycoplasmas is an efficient, inexpensive, reliable, and simple method: 150/200 (75%) chronically and heavily contaminated cultures were cured and 50/200 (25%) cultures could not be cleansed and were either lost or remained infected. It is concluded that eukaryotic cell cultures containing mycoplasmas are amenable to antibiotic treatment and that a cure rate of three-quarters is a reasonable expectation.  相似文献   

2.
Summary A nested polymerase chain reaction (PCR) was used to detect and identify mycoplasma contaminants in viral stocks. The results of the PCR assay proved to be a sensitive and accurate indicator of the true status of the stock tested. Those samples positive by agar culture or Hoechst stain were also positive by PCR. Those samples that were inconclusive by Hoechst stain (10.05%) could be clearly determined to be mycoplasma positive or negative by PCR. The PCR assay also detected those fastidious species of mycoplasma that gave false negative results by the direct culture method. In many respects the PCR-based mycoplasma detection method described is superior to the agar culture and Hoechst staining detection methods. In this study, the PCR assay detected substantially more mycoplasma-positive viral stocks than did the agar culture assay. Due to its speed, sensitivity, and reliability, the PCR assay is of particular value in monitoring the process of removing mycoplasma from contaminated stocks. Furthermore, the PCR amplification products can be analyzed by restriction analysis to rapidly identify the species of the mycoplasma contaminating the stock tested.  相似文献   

3.
细胞培养过程中的支原体污染相当普遍。如何快速、简便地检测支原体,并且采取有效措施去除支原体一直是细胞培养中急待解决的难题。本文就近年来有关支原体检测及去除方面的工作加以综述。  相似文献   

4.
Mycoplasma contamination events in biomanufacturing facilities can result in loss of production and costly cleanups. Mycoplasma may survive in mammalian cell cultures with only subtle changes to the culture and may penetrate the 0.2 µm filters often used in the primary clarification of harvested cell culture fluid. Culture cell-based and indicator cell-based assays that are used to detect mycoplasma are highly sensitive but can take up to 28 days to complete and cannot be used for real-time decision making during the biomanufacturing process. To support real-time measurements of mycoplasma contamination, there is a push to explore nucleic acid testing. However, cell-based methods measure growth or colony forming units and nucleic acid testing measures genome copy number; this has led to ambiguity regarding how to compare the sensitivity of the methods. In addition, the high risk of conducting experiments wherein one deliberately spikes mycoplasma into bioreactors has dissuaded commercial groups from performing studies to explore the multiple variables associated with the upstream effects of a mycoplasma contamination in a manufacturing setting. Here we studied the ability of Mycoplasma arginini to persist in a single-use, perfusion rocking bioreactor system containing a Chinese hamster ovary (CHO) DG44 cell line expressing a model monoclonal immunoglobulin G1 (IgG1) antibody. We examined M. arginini growth and detection by culture methods, as well as the effects of M. arginini on mammalian cell health, metabolism, and productivity. We compared process parameters and controls normally measured in bioreactors including dissolved oxygen, gas mix, and base addition to maintain pH, to examine parameter changes as potential indicators of contamination. Our work showed that M. arginini affects CHO cell growth profile, viability, nutrient consumption, oxygen use, and waste production at varying timepoints after M. arginini introduction to the culture. Importantly, how the M. arginini contamination impacts the CHO cells is influenced by the concentration of CHO cells and rate of perfusion at the time of M. arginini spike. Careful evaluation of dissolved oxygen, pH control parameters, ammonia, and arginine over time may be used to indicate mycoplasma contamination in CHO cell cultures in a bioreactor before a read-out from a traditional method.  相似文献   

5.
A fast and simple method to detect bacterial and especially mycoplasma contamination in tissue culture by means of polymerase chain reaction (PCR) amplification is described. In a first step the universal primer pairs P1/P2 (190-bp fragment) and P3/P4 (120-bp fragment) directed to different conserved parts of the prokaryotic 16S rRNA gene are used. A positive signal after amplification on cell culture DNA with these primers provides an indication of bacterial infection. Using the internal primers IP1, IP3 and IP'3 complementary to a part of the V4 and V8 variable regions of the 16S rRNA gene, in combination with a universal primer, cultures contaminated with mycoplasma could be identified. Six mycoplasma species, typical contaminants in tissue cultures, were investigated: Mycoplasma orale, M. fermentans, M. arginini, M. hyorhinis, M. hominis and Aeromonas laidlawii. This mycoplasma test is an easy, specific and sensitive assay which should be extremely useful in any tissue culture setting.  相似文献   

6.
Summary A contaminant belonging to the genusLeptospira was detected in different cell lines. This organism was isolated and identified asLeptospira biflexa, a saprophytic species commonly inhabiting fesh waters. The source of this contaminant was not ascertained.  相似文献   

7.
Detection of mycoplasma contaminations by the polymerase chain reaction   总被引:4,自引:0,他引:4  
The polymerase chain reaction (PCR) has been used for the general detection ofMollicutes. 25Mycoplasma andAcholeplasma species were detected including important contaminants of cell cultures such asM. orale, M. arginini, M. hyorhinis, M. fermentans, A. laidlawii and additional human and animal mycoplasmas. PCR reactions were performed using a set of nested primers defined from conserved regions of the 16S rRNA gene. The detection limit was determined to be 1 fg mycoplasma DNA, which is equivalent to 1–2 genome copies of the 16S rRNA coding region. The identity of the amplification products was confirmed by agarose gel electrophoresis and restriction enzyme analysis. DNA from closely and distantly related micro-organisms did not give rise to specific amplification products. The method presented here offers a much more sensitive, specific and rapid assay for the detection of mycoplasmas than the existing ones.  相似文献   

8.
Summary Human H. Ep-2 and mouse 3T6 cells infected byMycoplasma hyorhinis showed an increase in [3H]uracil uptake and a more than 20-fold increase in the activity of uracil phosphoribosyltransferase (UraPRT). Uninfected cell cultures gave background levels of this enzyme activity. A survey of 16 strains of mycoplasma showed 13 to possess UraPRT activity. Rabbit kidney cells (RK13) were infected with eight different strains of four mycoplasma species known to be common cell culture contaminants. Seven of the eight cell cultures showed elevated UraPRT activities four days after infection. This enzyme activity may be of value in monitoring cell cultures for mycoplasma and aid in classification. This work was supported by Contract NO1-CP-53530 with the National Cancer Institute, National Institutes of Health, and Contract FDA 74-41 of the Food and Drug Administration, Bethesda, Maryland 20014.  相似文献   

9.
A quantitative real-time polymerase chain reaction (PCR) procedure followed by melting curve analysis, using the green fluorescence dye SYBR Green I, was developed for rapid detection and differentiation of mycoplasma contaminants in cell cultures. This method showed that the detection of the target sequence was linear over a range from 10(4) to 10 colony-forming units (CFU) of the mycoplasma cells. Analysis of the melting temperature of the PCR products allowed differentiation of the major mycoplasma contaminants. These results demonstrate that the protocol described in the present study can decrease the time to obtain reproducible results by simultaneous detection and differentiation of the Mycoplasma species contaminating cell cultures.  相似文献   

10.
A new fluorescent acridine orange derivative, 3-amino-6-methoxy-9-(2-hydroxyethylamino) acridine (AMHA), has been applied to Hela cells in order to set up appropriate conditions for the detection of mycoplasma contaminations. Since AMHA staining reveals intensely fluorescent nuclei and slight fluorescent cytoplasm, we can visualize and localize mycoplasma contamination on each cell. In combination with a shortened Chen's staining method (1977), AMHA should allow a better detection of mycoplasma in animal cell cultures than the well established Hoechst dye.  相似文献   

11.
12.
Transmission electron microscopy has been employed for the rapid detection of mycoplasma in sera and cell cultures. High speed centrifugation of sera or low speed centrifugation of cell debris, followed by negative staining of the resuspended pellet, detected mycoplasma contamination more frequently than a culture method followed by direct fluorescence (DAPI), which was used as a control procedure. The appearance of the mycoplasma cell border and content gives some information about particle viability.  相似文献   

13.
A technique using the polymerase chain reaction (PCR) was developed for detection of the nucleopolyhedrovirus (NPV) polyhedrin gene. The amino acid sequences of the polyhedrin gene were compared in twenty-six NPVs. A highly conserved DNA sequence within the coding region of the polyhedrin gene was targeted for amplification. One pair of degenerate PCR primers was designed to produce fragments of about 430 bp. The NPVs detected by this technique were Autographa californica NPV, Bombyx mori NPV, Hyphantria cunea NPV, Spodoptera exigua NPV, S. litura NPV, and Lymantria dispar NPV. This technique would be useful in monitoring the distribution of NPVs and release of the wild type and recombinant NPVs.  相似文献   

14.
The contamination of cell cultures by mycoplasmas remains a major problem in cell culture. Mycoplasmas can produce a virtually unlimited variety of effects in the cultures they infect. These organisms are resistant to most antibiotics commonly employed in cell cultures. Here we provide a concise overview of the current knowledge on: (1) the incidence and sources of mycoplasma contamination in cell cultures, the mycoplasma species most commonly detected in cell cultures, and the effects of mycoplasmas on the function and activities of infected cell cultures; (2) the various techniques available for the detection of mycoplasmas with particular emphasis on the most reliable detection methods; (3) the various methods available for the elimination of mycoplasmas highlighting antibiotic treatment; and (4) the recommended procedures and working protocols for the detection, elimination and prevention of mycoplasma contamination. The availability of accurate, sensitive and reliable detection methods and the application of robust and successful elimination methods provide powerful means for overcoming the problem of mycoplasma contamination in cell cultures. This revised version was published online in August 2006 with corrections to the Cover Date.  相似文献   

15.
Summary Hamster BHK cells or secondary cultures of mouse embryo fibroblasts are not iodinated by lactoperoxidase in the absence of hydrogen peroxide. When such cell cultures are infected with a noncultivable strain ofM. hyorhinis, endogenous peroxide generation is sufficient to permit nearly maximal iodination. The SDS-polyacrylamide gel pattern of iodinated cell surface polypeptides is essentially the same regardless of the source of peroxide and whether or not the cultures are infected with mycoplasma.  相似文献   

16.
In this article we report a new biosensor‐based method that is more sensitive and rapid than the current approach for detecting mycoplasma in cell culture samples. Piezoelectric‐excited millimeter‐sized cantilever (PEMC) sensors respond to mass change via resonant frequency change. They are sensitive at femtogram level and can be used directly in liquid for label‐free detection. Common cell culture contaminant, Acholeplasma laidlawii was detected in both buffer and cell culture medium. Two different sources (positive control from a commercial kit and ATCC 23206) were analyzed using antibody‐immobilized PEMC sensor. Resonant frequency decrease caused by binding of A. laidlawii was monitored in real‐time using an impedance analyzer. Positive detection was confirmed by a second antibody binding. The limit of detection (LOD) was lower than 103 CFU/mL in cell culture medium using PEMC sensor while parallel ELISA assays showed LOD as 107 CFU/mL. This study shows that PEMC sensor can be used for sensitive and rapid mycoplasma detection in cell culture samples. Biotechnol. Bioeng. 2010;105: 1069–1077. © 2009 Wiley Periodicals, Inc.  相似文献   

17.
针对诺如病毒II型的保守区域设计引物,建立了SYBR Green I实时荧光RT-PCR检测诺如病毒II型的反应体系。此方法的病毒检测下限达到102拷贝,标准曲线的线形范围为102~106拷贝,相关系数为0.9952,斜率为?2.982,截距为35.84。对诺如病毒II型检测特异,与轮状病毒、腺病毒、甲肝病毒、星状病毒无交叉反应。针对质粒标准品检测的批内试验变异系数 (CV) 为0.95%~1.69% (n=5),批间试验CV为0.87%~1.24% (n=3)。运用此方法随机检测30份贝类水产品,检测出2份阳性样品。结果表明,SYBR Green I荧光RT-PCR检测诺如病毒II型的方法灵敏、特异、重复性好,可应用于贝类水产品的快速检测。  相似文献   

18.
19.
20.
Accumulating data implicate mycoplasma contamination as the single biggest problem in the culture of continuous cell lines. Mycoplasma infection can affect virtually every parameter and functional activity of the eukaryotic cells. A successful alternative to discarding infected cultures is to attempt to eliminate the contaminants by treatment with specific and efficient antimycoplasma antibiotics. The addition of antibiotics to the culture medium during a limited period of time (1-3 wk) is a simple, inexpensive, and very practical approach for decontaminating continuous cell lines. Here, we examined the effectiveness of several antibiotic treatment protocols that we have employed routinely in our cell lines bank. On an aggregate, 673 cultures from 236 chronically mycoplasma-positive cell lines were exposed to one of the following five antibiotic regimens: mycoplasma removal agent (quinolone; a 1-wk treatment), enrofloxacin (quinolone; 1 wk), sparfloxacin (quinolone; 1 wk), ciprofloxacin (quinolone; 2 wk), and BM-Cyclin (alternating tiamulin and minocycline; 3 wk). The mycoplasma infection was permanently (as determined by three solid mycoplasma detection assays) eliminated by the various antibiotics in 66-85% of the cultures treated. Mycoplasma resistance was seen in 7-21%, and loss of the culture as a result of cytotoxically caused cell death occurred in 3-11% of the cultures treated. Overall, 223 of the 236 mycoplasma-positive cell lines could be cured in a first round of antibiotic treatment with at least one regimen. Taken together, 95% of the mycoplasma-infected cell lines were permanently cleansed of the contaminants by antibiotic treatment, which validates this approach as an efficient and technically simple mycoplasma eradication method.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号