首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.

Background

The popularity of new sequencing technologies has led to an explosion of possible applications, including new approaches in biodiversity studies. However each of these sequencing technologies suffers from sequencing errors originating from different factors. For 16S rRNA metagenomics studies, the 454 pyrosequencing technology is one of the most frequently used platforms, but sequencing errors still lead to important data analysis issues (e.g. in clustering in taxonomic units and biodiversity estimation). Moreover, retaining a higher portion of the sequencing data by preserving as much of the read length as possible while maintaining the error rate within an acceptable range, will have important consequences at the level of taxonomic precision.

Results

The new error correction algorithm proposed in this work - NoDe (Noise Detector) - is trained to identify those positions in 454 sequencing reads that are likely to have an error, and subsequently clusters those error-prone reads with correct reads resulting in error-free representative read. A benchmarking study with other denoising algorithms shows that NoDe can detect up to 75% more errors in a large scale mock community dataset, and this with a low computational cost compared to the second best algorithm considered in this study. The positive effect of NoDe in 16S rRNA studies was confirmed by the beneficial effect on the precision of the clustering of pyrosequencing reads in operational taxonomic units.

Conclusions

NoDe was shown to be a computational efficient denoising algorithm for pyrosequencing reads, producing the lowest error rates in an extensive benchmarking study with other denoising algorithms.

Electronic supplementary material

The online version of this article (doi:10.1186/s12859-015-0520-5) contains supplementary material, which is available to authorized users.  相似文献   

2.
3.
4.

Background  

Next-generation sequencing technologies have led to the high-throughput production of sequence data (reads) at low cost. However, these reads are significantly shorter and more error-prone than conventional Sanger shotgun reads. This poses a challenge for the de novo assembly in terms of assembly quality and scalability for large-scale short read datasets.  相似文献   

5.

Background

16S rRNA gene pyrosequencing approach has revolutionized studies in microbial ecology. While primer selection and short read length can affect the resulting microbial community profile, little is known about the influence of pyrosequencing methods on the sequencing throughput and the outcome of microbial community analyses. The aim of this study is to compare differences in output, ease, and cost among three different amplicon pyrosequencing methods for the Roche/454 Titanium platform

Methodology/Principal Findings

The following three pyrosequencing methods for 16S rRNA genes were selected in this study: Method-1 (standard method) is the recommended method for bi-directional sequencing using the LIB-A kit; Method-2 is a new option designed in this study for unidirectional sequencing with the LIB-A kit; and Method-3 uses the LIB-L kit for unidirectional sequencing. In our comparison among these three methods using 10 different environmental samples, Method-2 and Method-3 produced 1.5–1.6 times more useable reads than the standard method (Method-1), after quality-based trimming, and did not compromise the outcome of microbial community analyses. Specifically, Method-3 is the most cost-effective unidirectional amplicon sequencing method as it provided the most reads and required the least effort in consumables management.

Conclusions

Our findings clearly demonstrated that alternative pyrosequencing methods for 16S rRNA genes could drastically affect sequencing output (e.g. number of reads before and after trimming) but have little effect on the outcomes of microbial community analysis. This finding is important for both researchers and sequencing facilities utilizing 16S rRNA gene pyrosequencing for microbial ecological studies.  相似文献   

6.

Background

Massively parallel sequencing offers an enormous potential for expression profiling, in particular for interspecific comparisons. Currently, different platforms for massively parallel sequencing are available, which differ in read length and sequencing costs. The 454-technology offers the highest read length. The other sequencing technologies are more cost effective, on the expense of shorter reads. Reliable expression profiling by massively parallel sequencing depends crucially on the accuracy to which the reads could be mapped to the corresponding genes.

Methodology/Principal Findings

We performed an in silico analysis to evaluate whether incorrect mapping of the sequence reads results in a biased expression pattern. A comparison of six available mapping software tools indicated a considerable heterogeneity in mapping speed and accuracy. Independently of the software used to map the reads, we found that for compact genomes both short (35 bp, 50 bp) and long sequence reads (100 bp) result in an almost unbiased expression pattern. In contrast, for species with a larger genome containing more gene families and repetitive DNA, shorter reads (35–50 bp) produced a considerable bias in gene expression. In humans, about 10% of the genes had fewer than 50% of the sequence reads correctly mapped. Sequence polymorphism up to 9% had almost no effect on the mapping accuracy of 100 bp reads. For 35 bp reads up to 3% sequence divergence did not affect the mapping accuracy strongly. The effect of indels on the mapping efficiency strongly depends on the mapping software.

Conclusions/Significance

In complex genomes, expression profiling by massively parallel sequencing could introduce a considerable bias due to incorrectly mapped sequence reads if the read length is short. Nevertheless, this bias could be accounted for if the genomic sequence is known. Furthermore, sequence polymorphisms and indels also affect the mapping accuracy and may cause a biased gene expression measurement. The choice of the mapping software is highly critical and the reliability depends on the presence/absence of indels and the divergence between reads and the reference genome. Overall, we found SSAHA2 and CLC to produce the most reliable mapping results.  相似文献   

7.

Objectives

To analyze the microbial diversity and gene content of a thermophilic cellulose-degrading consortium from hot springs in Xiamen, China using 454 pyrosequencing for discovering cellulolytic enzyme resources.

Results

A thermophilic cellulose-degrading consortium, XM70 that was isolated from a hot spring, used sugarcane bagasse as sole carbon and energy source. DNA sequencing of the XM70 sample resulted in 349,978 reads with an average read length of 380 bases, accounting for 133,896,867 bases of sequence information. The characterization of sequencing reads and assembled contigs revealed that most microbes were derived from four phyla: Geobacillus (Firmicutes), Thermus, Bacillus, and Anoxybacillus. Twenty-eight homologous genes belonging to 15 glycoside hydrolase families were detected, including several cellulase genes. A novel hot spring metagenome-derived thermophilic cellulase was expressed and characterized.

Conclusions

The application value of thermostable sugarcane bagasse-degrading enzymes is shown for production of cellulosic biofuel. The practical power of using a short-read-based metagenomic approach for harvesting novel microbial genes is also demonstrated.
  相似文献   

8.

Background

Second-generation sequencers generate millions of relatively short, but error-prone, reads. These errors make sequence assembly and other downstream projects more challenging. Correcting these errors improves the quality of assemblies and projects which benefit from error-free reads.

Results

We have developed a general-purpose error corrector that corrects errors introduced by Illumina, Ion Torrent, and Roche 454 sequencing technologies and can be applied to single- or mixed-genome data. In addition to correcting substitution errors, we locate and correct insertion, deletion, and homopolymer errors while remaining sensitive to low coverage areas of sequencing projects. Using published data sets, we correct 94% of Illumina MiSeq errors, 88% of Ion Torrent PGM errors, 85% of Roche 454 GS Junior errors. Introduced errors are 20 to 70 times more rare than successfully corrected errors. Furthermore, we show that the quality of assemblies improves when reads are corrected by our software.

Conclusions

Pollux is highly effective at correcting errors across platforms, and is consistently able to perform as well or better than currently available error correction software. Pollux provides general-purpose error correction and may be used in applications with or without assembly.  相似文献   

9.

Background  

High throughput sequencing (HTS) platforms produce gigabases of short read (<100 bp) data per run. While these short reads are adequate for resequencing applications, de novo assembly of moderate size genomes from such reads remains a significant challenge. These limitations could be partially overcome by utilizing mate pair technology, which provides pairs of short reads separated by a known distance along the genome.  相似文献   

10.

Background

Human leukocyte antigen (HLA) genes are critical genes involved in important biomedical aspects, including organ transplantation, autoimmune diseases and infectious diseases. The gene family contains the most polymorphic genes in humans and the difference between two alleles is only a single base pair substitution in many cases. The next generation sequencing (NGS) technologies could be used for high throughput HLA typing but in silico methods are still needed to correctly assign the alleles of a sample. Computer scientists have developed such methods for various NGS platforms, such as Illumina, Roche 454 and Ion Torrent, based on the characteristics of the reads they generate. However, the method for PacBio reads was less addressed, probably owing to its high error rates. The PacBio system has the longest read length among available NGS platforms, and therefore is the only platform capable of having exon 2 and exon 3 of HLA genes on the same read to unequivocally solve the ambiguity problem caused by the “phasing” issue.

Results

We proposed a new method BayesTyping1 to assign HLA alleles for PacBio circular consensus sequencing reads using Bayes’ theorem. The method was applied to simulated data of the three loci HLA-A, HLA-B and HLA-DRB1. The experimental results showed its capability to tolerate the disturbance of sequencing errors and external noise reads.

Conclusions

The BayesTyping1 method could overcome the problems of HLA typing using PacBio reads, which mostly arise from sequencing errors of PacBio reads and the divergence of HLA genes, to some extent.

Electronic supplementary material

The online version of this article (doi:10.1186/1471-2105-15-296) contains supplementary material, which is available to authorized users.  相似文献   

11.
12.
13.
14.
15.
16.

Background  

Recent advances in sequencing strategies make possible unprecedented depth and scale of sampling for molecular detection of microbial diversity. Two major paradigm-shifting discoveries include the detection of bacterial diversity that is one to two orders of magnitude greater than previous estimates, and the discovery of an exciting 'rare biosphere' of molecular signatures ('species') of poorly understood ecological significance. We applied a high-throughput parallel tag sequencing (454 sequencing) protocol adopted for eukaryotes to investigate protistan community complexity in two contrasting anoxic marine ecosystems (Framvaren Fjord, Norway; Cariaco deep-sea basin, Venezuela). Both sampling sites have previously been scrutinized for protistan diversity by traditional clone library construction and Sanger sequencing. By comparing these clone library data with 454 amplicon library data, we assess the efficiency of high-throughput tag sequencing strategies. We here present a novel, highly conservative bioinformatic analysis pipeline for the processing of large tag sequence data sets.  相似文献   

17.
Pyrosequencing of the 16S ribosomal RNA gene (16S) has become one of the most popular methods to assess microbial diversity. Pyrosequencing reads containing ambiguous bases (Ns) are generally discarded based on the assumptions of their non-sequence-dependent formation and high error rates. However, taxonomic composition differed by removal of reads with Ns. We determined whether Ns from pyrosequencing occur in a sequence-dependent manner. Our reads and the corresponding flow value data revealed occurrence of sequence-specific N errors with a common sequential pattern (a homopolymer + a few nucleotides with bases other than the homopolymer + N) and revealed that the nucleotide base of the homopolymer is the true base for the following N. Using an algorithm reflecting this sequence-dependent pattern, we corrected the Ns in the 16S (86.54%), bphD (81.37%) and nifH (81.55%) amplicon reads from a mock community with high precisions of 95.4, 96.9 and 100%, respectively. The new N correction method was applicable for determining most of Ns in amplicon reads from a soil sample, resulting in reducing taxonomic biases associated with N errors and in shotgun sequencing reads from public metagenome data. The method improves the accuracy and precision of microbial community analysis and genome sequencing using 454 pyrosequencing.  相似文献   

18.

Background

Long-read sequencing technologies were launched a few years ago, and in contrast with short-read sequencing technologies, they offered a promise of solving assembly problems for large and complex genomes. Moreover by providing long-range information, it could also solve haplotype phasing. However, existing long-read technologies still have several limitations that complicate their use for most research laboratories, as well as in large and/or complex genome projects. In 2014, Oxford Nanopore released the MinION® device, a small and low-cost single-molecule nanopore sequencer, which offers the possibility of sequencing long DNA fragments.

Results

The assembly of long reads generated using the Oxford Nanopore MinION® instrument is challenging as existing assemblers were not implemented to deal with long reads exhibiting close to 30% of errors. Here, we presented a hybrid approach developed to take advantage of data generated using MinION® device. We sequenced a well-known bacterium, Acinetobacter baylyi ADP1 and applied our method to obtain a highly contiguous (one single contig) and accurate genome assembly even in repetitive regions, in contrast to an Illumina-only assembly. Our hybrid strategy was able to generate NaS (Nanopore Synthetic-long) reads up to 60 kb that aligned entirely and with no error to the reference genome and that spanned highly conserved repetitive regions. The average accuracy of NaS reads reached 99.99% without losing the initial size of the input MinION® reads.

Conclusions

We described NaS tool, a hybrid approach allowing the sequencing of microbial genomes using the MinION® device. Our method, based ideally on 20x and 50x of NaS and Illumina reads respectively, provides an efficient and cost-effective way of sequencing microbial or small eukaryotic genomes in a very short time even in small facilities. Moreover, we demonstrated that although the Oxford Nanopore technology is a relatively new sequencing technology, currently with a high error rate, it is already useful in the generation of high-quality genome assemblies.

Electronic supplementary material

The online version of this article (doi:10.1186/s12864-015-1519-z) contains supplementary material, which is available to authorized users.  相似文献   

19.

Background

Usually, next generation sequencing (NGS) technology has the property of ultra-high throughput but the read length is remarkably short compared to conventional Sanger sequencing. Paired-end NGS could computationally extend the read length but with a lot of practical inconvenience because of the inherent gaps. Now that Illumina paired-end sequencing has the ability of read both ends from 600 bp or even 800 bp DNA fragments, how to fill in the gaps between paired ends to produce accurate long reads is intriguing but challenging.

Results

We have developed a new technology, referred to as pseudo-Sanger (PS) sequencing. It tries to fill in the gaps between paired ends and could generate near error-free sequences equivalent to the conventional Sanger reads in length but with the high throughput of the Next Generation Sequencing. The major novelty of PS method lies on that the gap filling is based on local assembly of paired-end reads which have overlaps with at either end. Thus, we are able to fill in the gaps in repetitive genomic region correctly. The PS sequencing starts with short reads from NGS platforms, using a series of paired-end libraries of stepwise decreasing insert sizes. A computational method is introduced to transform these special paired-end reads into long and near error-free PS sequences, which correspond in length to those with the largest insert sizes. The PS construction has 3 advantages over untransformed reads: gap filling, error correction and heterozygote tolerance. Among the many applications of the PS construction is de novo genome assembly, which we tested in this study. Assembly of PS reads from a non-isogenic strain of Drosophila melanogaster yields an N50 contig of 190 kb, a 5 fold improvement over the existing de novo assembly methods and a 3 fold advantage over the assembly of long reads from 454 sequencing.

Conclusions

Our method generated near error-free long reads from NGS paired-end sequencing. We demonstrated that de novo assembly could benefit a lot from these Sanger-like reads. Besides, the characteristic of the long reads could be applied to such applications as structural variations detection and metagenomics.

Electronic supplementary material

The online version of this article (doi:10.1186/1471-2164-14-711) contains supplementary material, which is available to authorized users.  相似文献   

20.
The ultimate goal of metagenome research projects is to understand the ecological roles and physiological functions of the microbial communities in a given natural environment. The 454 pyrosequencing platform produces the longest reads among the most widely used next generation sequencing platforms. Since the relatively longer reads of the 454 platform provide more information for identification of microbial sequences, this platform is dedicated to microbial community and population studies. In order to accurately perform the downstream analysis of the 454 multiplex datasets, it is necessary to remove artificially designed sequences located at either ends of individual reads and to correct low-quality sequences. We have developed a program called PyroTrimmer that removes the barcodes, linkers, and primers, trims sequence regions with low quality scores, and filters out low-quality sequence reads. Although these functions have previously been implemented in other programs as well, PyroTrimmer has novelty in terms of the following features: i) more sensitive primer detection using Levenstein distance and global pairwise alignment, ii) the first stand-alone software with a graphic user interface, and iii) various options for trimming and filtering out the low-quality sequence reads. PyroTrimmer, written in JAVA, is compatible with multiple operating systems and can be downloaded free at http://pyrotrimmer.kobic.re.kr.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号